Skip to Content
MembranesMembranes
  • Article
  • Open Access

28 November 2026

27 Pages

Assessment of a Low-Cost Ceramic Membrane Bioreactor for Treating Real Hospital Wastewater: Applications in Small Healthcare Facilities

,
,
,
,
,
,
,
and
1
Department of Civil Engineering, College of Engineering, Qassim University, Buraydah 51452, Saudi Arabia
2
Department of Chemistry, College of Science, Qassim University, Buraydah 51452, Saudi Arabia
3
Civil Engineering Department, Faculty of Engineering, Islamic University of Madinah, Madinah 42351, Saudi Arabia
*
Author to whom correspondence should be addressed.
Membranes2026, 16(12), 412;https://doi.org/10.3390/membranes16120412 
(registering DOI)
This article belongs to the Special Issue Ceramic Membranes for Wastewater and Water Reuse (2nd Edition)

Abstract

This study presents one of the first laboratory-scale evaluations of a low-cost ceramic membrane bioreactor (LCMBR) for treating real hospital wastewater. The system employed a locally fabricated ceramic membrane integrated with a biological reactor to achieve simultaneous biological degradation and membrane filtration. The study monitored key water quality parameters, including chemical oxygen demand (COD), biochemical oxygen demand (BOD5), suspended solids (SS), nitrogen species, phosphate (PO4-P), and 15 selected heavy metals, to assess treatment efficiency. The LCMBR achieved more than 80% removal of organic pollutants, reducing effluent COD and BOD to less than 15 mg L−1 and 10 mg L−1, respectively. The LCMBR achieved ~60–70% of total inorganic nitrogen and moderate (40–60%) phosphorus removal, primarily through biological assimilation and adsorption. Changes in inorganic nitrogen and phosphate concentrations indicated partial nutrient removal, although the specific nitrogen and phosphorus transformation pathways were not directly established. The LCMBR system effectively removed fifteen trace metals, including Al, V, Cr, Mn, Fe, Co, Ni, Zn, Cu, Cd, As, Mo, Pb, Sb, and Ba, through adsorption onto the biomass. The treated effluent quality was well below the recommended international discharge standards. Membrane flux declined during the final part of the experimental period and recovered after physical cleaning. A preliminary engineering assessment for a hypothetical decentralized treatment facility with a design capacity of 10 m−3 d−1 estimated an energy requirement of approximately 0.133 kWh m−3 under the specified assumptions. The LCMBR offers a cost-effective and sustainable option for decentralized hospital wastewater treatment.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.