Skip to Content
You are currently on the new version of our website. Access the old version .
Applied SciencesApplied Sciences
  • Article
  • Open Access

12 March 2026

20 Pages

Ground-Penetrating Radar Contamination Analysis Method Based on Time–Frequency Features and Ballast Condition

,
and
1
China Energy Shuohuang Railway Development Co., Ltd., Cangzhou 062350, China
2
Hangzhou Institute of Technology, Xidian University, Hangzhou 311231, China
*
Author to whom correspondence should be addressed.

Abstract

On heavy-haul railways, ballast fouling progressively reduces ballast resistance, which in turn degrades the electrical performance of track circuits. To address this cascading issue, we propose a ground-penetrating radar (GPR)-based method for assessing ballast bed conditions and inverting ballast resistance R b continuously along the track. First, by integrating transmission line theory with Archie’s law, this paper establishes the mechanistic link between microscale dielectric deterioration of the fouled ballast and the macroscale electrical parameters of the track circuit. Next, we build a full-wave electromagnetic simulation model to extract two key GPR signal features: time-domain relative energy attenuation and frequency-domain spectral redshift. Recognizing the limitations of single-feature analysis, we introduce an adaptive weight-based multi-feature fusion algorithm to construct a comprehensive fouling index that quantifies the physical state of the ballast. Based on this index, we develop a quantitative mapping model between the fouling index (FI) and R b , enabling continuous inversion of ballast resistance over the entire line. Our results show excellent agreement between the inverted R b profile and the theoretical ground truth, with the FI alarm threshold precisely corresponding to the critical safety limit of R b = 0.5 Ω km. This approach effectively overcomes the limitations of traditional discrete monitoring and provides a practical tool for predictive maintenance of track circuits.

1. Introduction

Under the rapid development of heavy-haul railway transportation, ensuring the safety, stability, and reliability of track circuits is critical. However, complex environmental conditions and ballast bed deterioration often degrade track circuit transmission characteristics, causing signal anomalies or equipment failures that disrupt operations. Although railway authorities prioritize online monitoring and fault diagnosis, poor ballast conditions—among other external factors—significantly alter signal behavior, making fault identification difficult. As demands for higher efficiency, safety, and service quality grow, intelligent and proactive maintenance strategies are urgently needed. Ground-penetrating radar (GPR) provides a non-destructive means to assess ballast conditions [1]. By combining GPR data acquisition with advanced algorithms, this approach enables track circuit health assessment and performance prediction, laying the methodological foundation for future preventive maintenance.

1.1. Research Background

Heavy-haul railway operations, characterized by high axle loads and dense traffic, impose severe challenges on track circuit systems. Statistical data show that on lines with annual tonnage exceeding 300 million tons, the rate of ballast bed deterioration is 2–3 times higher than that on conventional railways, directly degrading the transmission characteristics of track circuits [2]. As a result, track circuit systems are under unprecedented operational stress.
Traditional maintenance practices suffer from three critical limitations:
  • Monitoring blind spots: Current systems lack real-time perception capability of ballast bed conditions;
  • Data silos: Monitoring systems operate independently, preventing effective data fusion;
  • Delayed decision-making: Threshold-based alarm mechanisms prevent early warning.
Approximately 60% of ballast resistance degradation in heavy-haul railways is attributed to ballast fouling. When ballast resistance Rb drops below 0.5 Ω⋅km, the probability of transmission performance degradation increases dramatically. According to 2023 statistics from China State Railway Group, 38% of track circuit failures on heavy-haul lines are directly linked to ballast deterioration, with an average repair time of 4.2 h and less than 30% of maintenance activities being preventive. According to the long-term field maintenance statistics from China’s heavy-haul railways (such as the Shuohuang Railway) and related condition-monitoring studies [3,4], various environmental and operational factors jointly contribute to the rapid deterioration of the ballast bed. As summarized in Table 1, these factors severely impact the track circuit performance.
Table 1. Impact of ballast bed conditions on track circuits.

1.2. Technical Status

The ballast bed serves as the electrical return path for track circuits, and its condition, such as fouling and caking, moisture content variation, and ballast material degradation, directly governs ballast resistance, which is a key parameter influencing track circuit performance. Deterioration in these aspects can lead to increased signal attenuation and even critical failures like “red light bands” [5]. Therefore, accurate assessment and proactive prediction of track circuit transmission quality require overcoming the technical bottleneck in multidimensional, real-time, and intelligent perception and analysis of ballast bed conditions. Traditional maintenance practices primarily focus on equipment-level parameters and lack systematic evaluation of how the ballast state affects overall circuit behavior. Currently, existing track circuit monitoring methods primarily rely on electrical inversion techniques, such as estimating ballast resistance through the envelope features of locomotive-induced voltages [6]. While effective, these contact-based methods depend heavily on train operation data and are vulnerable to interference from electrical component failures. On the other hand, ground-penetrating radar has been widely recognized as a robust non-destructive tool for evaluating physical fouling, especially coal dust contamination and moisture accumulation in heavy-haul railways (as comprehensively reviewed in [7]). However, most GPR studies stop at the qualitative assessment of the ballast bed, lacking systematic integration with the electrical performance of track circuits.
To address this gap, this paper establishes a quantitative coupling mechanism between the physical dielectric deterioration of the ballast and the track circuit electrical parameters. Instead of merely identifying fouled areas, we innovatively extract time–frequency features from GPR signals to construct a comprehensive fouling index and propose a mapping model to continuously invert the macroscopic ballast resistance R b . This provides a non-contact, predictive maintenance tool that does not interfere with train operations.

2. The Coupling Mechanism Between the Ballast Condition and the Track Circuit

2.1. Electromagnetic Principle of Ground-Penetrating Radar

Ground-penetrating radar is a non-destructive testing system that uses high-frequency electromagnetic waves to probe subsurface structures and material distributions [8]. It consists of five main components: a central control unit, a GPR transmitter, a transmitting antenna, a GPR receiver, and a receiving antenna. The central control unit acts as the system’s core, managing overall operation—including parameter configuration, command issuance, data acquisition, and preliminary signal processing. The transmitter generates and controls high-frequency electromagnetic pulses, which are then delivered into the subsurface medium via the transmitting antenna. This antenna, typically designed as a wideband antenna, converts electrical energy into electromagnetic wave energy and radiates it into the ground to ensure effective penetration through various soils or materials. The receiver captures the returning electromagnetic signals, while the receiving antenna—either physically separate from or shared with the transmitting antenna—is dedicated to collecting the reflected waves.
In the specific context of railway ballast condition assessment, the GPR operational scenario can be simplified as shown in Figure 1.
Figure 1. Schematic diagram of the GPR operational scenario corresponding to the A-scan.
As shown in Figure 1, the GPR transmitting antennas emit electromagnetic waves into the ground. Strong reflection echoes occur at different interfaces, corresponding to sharp amplitude increases in the A-scan trace. Simultaneously, interactions with various subsurface materials generate complex scattering and multiple reflections, forming a single A-scan waveform. By stepping the antennas along the horizontal direction and recording multiple A-scans, a B-scan image is constructed, which enables accurate characterization of varying ballast bed conditions.
Figure 2 presents a visual demonstration of the practical field experimental implementation on an operational train track. The integrated system is deployed on a Specialized Test Carrier designed to move along the rails. The multi-channel data acquisition configuration features a central control unit (Radar Center) and three suspended radar antennas—left, center, and right—to facilitate comprehensive scanning of the ballast bed. An integrated distance encoder ensures precise trace position logging.
Figure 2. GPR equipment on a ballasted track.

2.2. Transmission Line Model of the Track Circuit

The track circuit is not only a train occupancy detection system but also a signal transmission system that uses the rails as conductors. In heavy-haul railway environments, the ballast bed—serving as the support foundation for the rails—directly contributes to the shunt admittance parameters of the transmission line through its dielectric properties. To reveal the influence mechanism of ballast fouling on signal transmission, this section establishes a distributed-parameter model of the track circuit based on transmission line theory [9].
According to railway signal transmission theory and the work by Xing et al. [10], when analyzing the electrical characteristics of the ballast bed, the track circuit can be equivalently modeled as a lossy transmission line with distributed parameters. Taking the ZPW-2000 system as an example, the electrical transmission behavior of a main track section of length l can be described by the transmission matrix A of a two-port network:
A = A B C D = cosh γ l Z c sinh γ l 1 Z c sinh γ l cosh γ l
where γ is the propagation constant (with the dimension of 1/km) and Z c is the characteristic impedance (with the dimension of Ω). These two core parameters are entirely determined by the per-unit-length series impedance Z (dimension: Ω/km) and shunt admittance Y (dimension: S/km) of the rail line:
γ = Z · Y ,   Z c = Z / Y
In the above model, the series impedance Z is primarily determined by the intrinsic physical properties of the rails, such as resistivity and the cross-sectional area, and remains relatively stable. In contrast, the shunt admittance Y directly reflects the inter-rail insulation condition and is composed of the leakage conductance G and the inter-rail capacitance C:
Y = G + j ω C = 1 R b + j ω C
It is worth noting that in the standard transmission line modeling of audio-frequency track circuits like the ZPW-2000 system, the distributed capacitance C between the steel rails is extremely small and is generally neglected [11]. Quantitatively, at operating frequencies of 1700–2600 Hz, the capacitive susceptance ω C is only about 0.016 S/km. When the ballast becomes fouled and wet, R b drops significantly, resulting in a leakage conductance of G  ≥ 1.0 S/km. Since G  ≫   ω C , the capacitive term j ω C contributes negligibly to signal attenuation. Therefore, R b acts as the absolute dominant indicator for evaluating the insulation performance of the ballast bed.
Among these, ballast resistance R b is the key indicator for evaluating the insulation performance of the ballast bed.
Existing electrical monitoring methods typically infer Rb from envelope features of the induced voltage in locomotive signals. However, such “electrical inversion” approaches rely on train operation data and are susceptible to interference from failures of electrical components, such as compensation capacitors.
In contrast, this paper proposes a physically grounded approach: since ballast fouling and moisture directly reduce R b , we can use ground-penetrating radar to directly probe the dielectric property distribution of the ballast bed and establish a mapping model from the physical fouling state to the electrical parameter Rb. This method enables static, continuous assessment of track circuit health without relying on train operation data and provides the theoretical foundation for subsequent simulation modeling and feature inversion.
To quantitatively describe the physical relationship between ballast fouling degree, moisture content, and macroscopic R b , this paper introduces the classical Archie’s law from petroleum logging [12]. Although originally developed to characterize the conductivity of water-saturated rocks, this model has been widely applied to GPR-based ballast property inversion due to the structural similarity between fouled ballast (composed of aggregates, pores, water, and fine contaminants) and porous media [13].
In fouled ballast, current conduction primarily occurs through conductive pore-filling materials. According to Archie’s formula, the effective resistivity ρ b of the mixed medium relates to porosity and fluid saturation as follows:
ρ b = a · ϕ − m · S w − n · ρ w
where
  • ρ b : Bulk resistivity of the ballast bed mixture Ω m, whose reciprocal is the conductivity σ.
  • ρ w : Resistivity of the pore fluid Ω m, which is significantly reduced in railway environments due to infiltration of coal dust and clay.
  • ϕ: Porosity of the ballast bed, defined as the ratio of pore volume to total volume. Clean ballast exhibits higher porosity, whereas fouling reduces it by filling voids.
  • S w : Water saturation, expressed as the percentage of pore volume occupied by water.
  • a : Lithology coefficient, typically set to one.
  • m: The cementation exponent, reflecting particle shape and packing; it typically ranges from 1.3 to 2.0 for spherical particles.
  • n: The saturation exponent, typically around two.
It follows that ρ b  is highly sensitive to water saturation S w . In clean ballast, S w − n approaches infinity, resulting in very high ρ b . When fine-grained contaminants fill the voids, they not only alter the pore structure parameters but, more critically, also exhibit strong capillary water absorption. This causes S w to increase significantly under identical rainfall conditions and hinders natural drying. Consequently, we infer that increasing fouling enhances the ballast’s water retention capacity and elevates the pore water conductivity, jointly driving an exponential decline in ballast resistivity.
In track circuits, ballast resistance R b ( Ω · k m ) is a macroscopic distributed parameter. According to classical transmission line modeling [9] and Ohm’s law, R b can be derived through a geometric equivalence of the parallel resistance over a 1 km track section. Considering the effective conduction depth and equivalent conduction width of the leakage current beneath the sleepers, it is expressed as
R b = ρ b · h e f f W e f f · 1 1000
where h e f f is the effective conduction depth and W e f f is the equivalent conduction width.
Equation (5) establishes a complete physical chain linking microscopic material properties to bulk resistivity and ultimately to macroscopic electrical parameters. It also serves as the theoretical foundation for the subsequent simulation modeling and validation in this paper.

3. Simulation

3.1. Simulation Scenario Construction

This study constructs a realistic ballast bed model based on an actual railway track bed structure, following standard ballast-laying specifications while incorporating minor simplifications to facilitate pattern analysis and summarization. The final model features randomly distributed particles with physical gradation matching real-world conditions, as illustrated in Figure 3.
Figure 3. 2D Schematic of the random ballast model. (a): overall model; (b): 0–5 m detail; (c): 5–10 m detail; and (d): 10–15 m detail.
As shown in Figure 3a, the model has an overall dimension of 15 m × 1.2 m. Horizontally, it is divided into three 5 m long zones, namely the clean zone, transition zone, and fouled zone, with detailed views shown in subfigures (b), (c), and (d), respectively. The brown regions represent ballast particles modeled as randomly generated polygons to simulate irregularly shaped natural ballast. A relative permittivity of 5.5 is assigned. To highlight electromagnetic differences caused by “fouling fill,” the ballast’s conductivity is set to 0 S/m—simulating a completely dry, non-conductive ballast. To avoid scattering intensity variations due to particle size differences, all ballast particles across the model are standardized to a single gradation class, as listed in Table 2, enabling effective variable control and minimizing noise while emphasizing targeted differences.
Table 2. Gradation composition of the simulation model.
Due to long-term railway operation and climatic effects, fouling media gradually fill the ballast voids, leading to functional degradation of the ballast bed [14]. In the model, blue regions represent fouling fill: in the 5–10 m transition zone, 30% of the pore space is filled with this medium; in the 10–15 m heavily fouled zone, the filling ratio reaches 75%, indicating severe contamination. This study focuses on electromagnetic property changes induced by fouling, not on the origin of the fouling itself. Thus, fouling is modeled as a simplified medium with a relative permittivity of 20 and a conductivity of 0.2 S/m.
Red regions denote sleepers, each measuring 0.3 m (length) × 0.24 m (width) × 0.22 m (height), spaced 0.3 m apart. Their material is assigned a relative permittivity of nine. Notably, in both the simulation and real GPR field testing, sleepers are typically treated as interference objects or dielectric blocks. Many researchers aim to suppress sleeper-induced artifacts to recover true ballast responses. Therefore, in this simulation, sleepers are retained but set to be electrically insulating (conductivity = 0 S/m) to minimize their impact on electromagnetic wave propagation.
It is worth mentioning that to isolate the electromagnetic responses specifically caused by varying degrees of fouling severity, this study deliberately employs a standardized ballast gradation and a specific high-moisture fouling type as a controlled baseline. In real-world heavy-haul operations, track conditions exhibit immense variability, including varying degrees of particle degradation and diverse fouling materials (e.g., coal dust, clay, and windblown sand) with different dielectric properties. While these complex variables exist, utilizing a standardized model in this proof-of-concept stage effectively prevents the confounding interference of differing rock gradations or ballast fouling. This controlled framework successfully validates the proposed multi-feature fusion methodology, providing a solid theoretical foundation. Future expansions of the simulation matrix will incorporate diverse gradations and multi-source fouling materials to further enhance the model’s generalizability for complex field applications.

3.2. Simulation Results

Electromagnetic simulations were conducted using gprMax (v3.1.7) [15], an open-source finite-difference time-domain (FDTD) solver specifically designed for ground-penetrating radar modeling. The source signal was defined as a Ricker wavelet with a central frequency of 1.5 GHz. The mesh size was set to ∆ x   =   ∆ y   = ∆ z   =   0.001   m . The temporal resolution (time step ∆ t ) was set to approximately 2.44 × 10 − 11   s , corresponding to a 25 ns simulation time window with 1024 sampling points per trace. A total of 720 A-scans were simulated along the 15 m track section, producing the results shown in Figure 4: simulation results—model, B-scan, and representative A-scans by zone.
Figure 4. Simulation results: model, B-scan, and representative A-scans by zone.
As shown, the upper panel displays the geometric model, while the middle panel presents the corresponding B-scan, and the lower panel shows representative single A-scan traces extracted from each 5 m zone. In the B-scan, adjacent white dashed lines mark the boundaries of the clean (0–5 m), transition (5–10 m), and fouled (10–15 m) zones, with the associated A-scan waveforms aligned directly below.

3.3. Data Preprocessing

Field GPR measurements over ballast layers are commonly contaminated by interference from sleepers, rails, and environmental noise. Consequently, the received GPR signals contain electromagnetic noise and multiple artifacts, including background clutter, sleeper diffractions, and layered reflections. Therefore, data preprocessing is a critical prerequisite for subsequent analysis, regardless of whether the data originate from simulations or field measurements. The preprocessing steps adopted in this study are as follows:
  • Zero-point drift correction: Due to electronic drift, temperature variations, or inherent DC offsets in the GPR receiver, raw A-scan signals typically exhibit a constant voltage bias rather than oscillating symmetrically around zero amplitude. This offset compresses the signal’s dynamic range and introduces low-frequency artifacts in spectral analysis or filtering. To correct this, we perform zero-point drift correction on each trace by subtracting its mean value, thereby recentering the baseline to zero. For a single A-scan data sequence X n , t of length N, the corrected signal X’ is given by
    X ′ n , t = X n , t − 1 N ∑ k = 1 N   X n , t
  • Frequency filter: During data acquisition, GPR systems typically record signals in an all-pass mode to avoid losing any information, which results in both useful reflections and interference being captured simultaneously. To suppress unwanted interference, we apply digital filtering [16]. Specifically, we use an FIR bandpass filter with a passband of 500 MHz to 2500 MHz.
  • F–K filtering: In railway ballast inspection, concrete sleepers are arranged at regular intervals along the track. These periodically spaced strong scatterers generate repetitive hyperbolic diffractions in the B-scan, which severely obscure the underlying ballast scattering responses and hinder accurate assessment of fouling severity. Because sleeper-induced interference exhibits strong spatial periodicity while fouling-related scattering is spatially random, their energy distributions differ distinctly in the frequency–wavenumber domain. To exploit this difference, we employ a two-dimensional F–K filtering technique to isolate and remove sleeper artifacts [17]. The algorithm proceeds as follows:
    (1)
    2D spectral mapping: Apply a two-dimensional discrete Fourier transform to the filtered B-scan data d ( x , t ) , converting it into the frequency–wavenumber domain D ( k x , ω )
    D k x , ω = ∬ − ∞ + ∞   d x , t e − j k x x + ω t d x d t
    where x denotes the spatial position along the track, t is the two-way travel time, k x  is the spatial wavenumber, and ω is the angular frequency.
    (2)
    Sleeper feature identification and filtering: In the f–k spectrum, the energy from periodic sleeper reflections concentrates at specific wavenumbers k s l e e p e r s  and their higher-order harmonics, appearing as bright vertical bands or spots aligned with the k x -axis. In contrast, scattering from the fouled ballast exhibits a diffuse energy distribution across the entire spectral domain. We design a two-dimensional filter H k x , ω that suppresses energy at the wavenumbers associated with sleepers while preserving the spectral components corresponding to ballast scattering.
    D ′ k x , ω = D k x , ω · H k x , ω
    where D ′ ( k x , ω ) denotes the filtered spectrum.
    (3)
    Wavefield reconstruction: We apply a two-dimensional inverse Fourier transform to the filtered spectrum D ′ ( k x , ω )  to reconstruct the data back into the space–time domain, yielding a B-scan image d ′ ( x , t ) with sleeper-induced interference effectively removed.
    d ′ x , t = 1 4 π 2 ∬ − ∞ + ∞   D ′ k x , ω e j k x x + ω t d k x d ω
  • Background subtraction: During GPR surveying, strong direct coupling between the transmitting and receiving antennas, along with intense reflections at the air–ballast interface, generates high-energy, near-horizontal band-like artifacts in the B-scan [18]. These signals severely compress the effective dynamic range and obscure weak internal scattering features from the ballast bed. To mitigate this, we apply a sliding background removal step using a window of 20 consecutive A-scans.
The results of each preprocessing step are shown in Figure 5 below. All subsequent operations in this paper shall be performed on the data after background subtraction (e).
Figure 5. Full process of data preprocessing: B-scan results.
Figure 6 illustrates the progressive preprocessing of representative A-scan traces from the clean, transition, and severely fouled zones. Since the high-amplitude direct coupling wave dominates the early arrival time (<3.5 ns), a zoomed-in inset (3.5–25 ns) is provided to visualize the relatively weak internal scattering signals of the ballast. These detailed views clearly demonstrate that severe fouling induces significant amplitude attenuation and time delay due to the strong electromagnetic absorption of the wet mud.
Figure 6. Full process of data preprocessing: A-scan results.

4. GPR Signal Time–Frequency Feature Extraction and Correlation Analysis with Ballast Resistance

Although the preprocessed GPR signals are free from major interference, they remain as qualitative image data. This chapter aims to extract quantitative features in both the time and frequency domains, develop sensitive feature indicators, and thereby achieve a digital characterization of ballast fouling conditions.

4.1. Time-Domain Feature: Relative Energy Attenuation

The propagation characteristics of electromagnetic waves in lossy media are governed by the complex permittivity ε * , which is expressed as
ε * = ε ′ − j ε ″ = ε ′ − j ε p o l a r ″ + σ ω
where the real part ε ′ represents the energy storage capacity and the imaginary part ε ″ represents the loss capability. The imaginary part primarily consists of two components: polarization loss ε p o l a r ″ and conductive loss σ ω .
In the specific context of ballast fouling on heavy-haul railways, clean ballast is mainly filled with air (σ ≈ 0), resulting in very low dielectric loss; electromagnetic wave attenuation is thus dominated by geometric spreading and interface scattering. However, when fine contaminants such as coal dust and clay infiltrate the ballast and accumulate moisture, the physical properties of the medium undergo fundamental changes.
First, conductive loss arises: water mixed with contaminants forms a complex conductive medium, significantly increasing the effective conductivity σ e f f . According to Maxwell’s equations, this enhanced current density dissipates electromagnetic energy as Joule heat. Second, polarization loss occurs: water molecules, being highly polar, undergo orientation polarization under the alternating electromagnetic field, and their relaxation processes consume additional electromagnetic energy.
Given the propagation constant γ = α + j β , the attenuation constant α is approximately proportional to conductivity. Consequently, as fouling severity and moisture content increase, the energy of deep-reflected GPR signals decays exponentially [19]. By quantifying this energy loss, we can inversely infer the internal fouling state of the ballast bed.
To quantitatively characterize the energy attenuation in deep ballast layers, this paper proposes relative energy attenuation as a time-domain feature indicator that is computed in three steps:
Step 1: Deep-time window extraction: To avoid masking of attenuation features by strong near-surface reflections, we select a deep time window that covers the bottom of the ballast layer and the subgrade interface. For the x-th GPR trace s ( x , t ) , we extract the signal segment within the time interval [ t s t a r t , t e n d ] .
S R O I x , t = s x , t , t ∈ t s t a r t , t e n d
In this study, the time window for computing the region of interest is set to 8–21 ns. This selection is physically grounded in the track structure: the sleeper top surface appears at approximately 3.5 ns. For a standard concrete sleeper (height 22 cm, ε r = 9 ), the two-way electromagnetic travel time is about 4.4 ns. Thus, the ballast top interface begins at roughly 3.5 + 4.4 = 7.9 ns ( ≈ 8 n s ). The 21 ns end time is selected to robustly encompass the ballast–subgrade interface, accommodating wave velocity variations caused by heterogeneous fouling conditions.
Step 2: Root mean square (RMS) energy calculation: We use the RMS amplitude to represent the average energy level E(x) within the selected time window.
E x = 1 N ∑ k = 1 N   | S R O I ( x , k ) | 2
where N is the number of samples within the time window.
Step 3: Logarithmic relative attenuation calculation: Because electromagnetic wave attenuation in lossy media is exponential, linear metrics struggle to resolve subtle energy variations in deep layers. To address this, we adopt a logarithmic scale and define the reference energy   E r e f as the average energy from the clean ballast zone. The relative attenuation in decibels L d B ( x ) is then computed as
L d B x = 20   log 10 E r e f E x
This metric has a clear physical interpretation: a larger L d B ( x ) indicates stronger electromagnetic wave absorption by the medium, corresponding to higher levels of ballast fouling and moisture content.
Applying the above algorithm to the simulated GPR data yields the results shown in Figure 7 below. It should be emphasized that the vertical dashed lines at 5 m and 10 m in the following figures are not arbitrary segmentations based on the data curves but instead correspond strictly to the physical boundaries of the simulation model (as defined in Section 3.1).
Figure 7. Relative energy attenuation analysis results: (a) original GPR B-scan, segmented every 5 m; (b) relative energy attenuation curve.
As shown, variations in ballast fouling significantly affect the time-domain energy characteristics of GPR signals. In the clean zone (0–5 m), the ballast is dry and uncontaminated, resulting in minimal dielectric loss. The B-scan exhibits clear reflection textures, and the attenuation curve fluctuates slightly around 0 dB, indicating negligible energy loss and a high signal-to-noise ratio. In the transition zone (5–10 m), with a 30% fouling fill ratio, additional scattering centers form and a small amount of moisture accumulates. The B-scan gradually darkens with increased clutter, and the attenuation curve rises moderately to an average of 1–2 dB, reflecting increased ohmic loss due to elevated conductivity. In the heavily fouled zone (10–15 m), where the fill ratio reaches 75% under high water saturation, the B-scan brightness drops sharply and deep-layer textures nearly vanish. The attenuation curve surges exponentially, exceeding 5 dB at its peak—indicating strong dielectric relaxation and conductive losses from high moisture content, which severely absorb electromagnetic energy.
The observed localized fluctuations along the curve are physically realistic responses to the highly heterogeneous nature of the stochastic ballast model. Because the conductive wet mud fills the irregular, randomly distributed pore spaces between the discrete polygonal ballast particles, the localized scattering and absorption vary from trace to trace. Despite these variations, the regional average of the energy attenuation clearly demonstrates a massive overall increase corresponding to the severe fouling condition.

4.2. Frequency-Domain Feature: Spectral Redshift

GPR source wavelets typically possess broadband spectral characteristics. When propagating through heterogeneous, lossy media, the signal’s spectrum undergoes significant distortion that is primarily driven by two frequency-dependent mechanisms:
First, Rayleigh and Mie scattering: Fine contaminants such as silt or coal dust act as scatterers. Scattering theory dictates that when the electromagnetic wavelength approaches the scatterer size, scattering intensity increases sharply with frequency. Consequently, high-frequency components are preferentially scattered away and fail to return to the receiver. Second, relaxation absorption loss: Water molecules in moist ballast exhibit polarization relaxation. Within the GPR operating band, the effective conductivity σ(ω) generally increases with frequency. According to the skin depth formula δ = 2 / ω μ σ [20], higher frequencies experience shallower penetration and are preferentially absorbed as heat.
Thus, a wet fouled ballast bed acts as a low-pass filter. As propagation distance increases, high-frequency components attenuate much faster than low-frequency ones, shifting the spectral energy centroid toward lower frequencies—a phenomenon known as spectral redshift [21]. Monitoring this center-frequency shift therefore provides an effective means to infer with internal fouling and moisture conditions.
To quantitatively characterize the spectral distribution, this paper adopts the spectral centroid as the key feature indicator. Unlike peak frequency, the spectral centroid incorporates energy distribution across the entire bandwidth, offering superior noise resilience and stability. The algorithm proceeds in three steps:
Step 1: Spectral transformation of the time-windowed signal: We apply a fast Fourier transform to the preprocessed deep-time window signal S R O I ( x , t ) to obtain its amplitude spectrum A ( x , f ) and power spectral density P ( x , f ) .
P ( x , f ) = | F F T ( S R O I ( x , t ) ) | 2
Step 2: Spectral centroid calculation: The spectral centroid f c x is defined as the weighted average frequency, with frequency as the variable and power spectral density as the weight. It is computed as follows:
f c x = ∫ f m i n f m a x   f · P x , f d f ∫ f m i n f m a x   P x , f d f
where [ f m i n , f m a x ] denotes the effective analysis bandwidth and is selected to exclude low-frequency DC interference and high-frequency noise. In this study, the bandwidth is set to 0.5–2.5 GHz.
Step 3: Quantification of spectral redshift: To intuitively reflect the severity of fouling, we define the frequency redshift Δ f ( x ) relative to the clean ballast zone as
Δ f x = f r e f − f c x
where f r e f is the average spectral centroid in the clean, dry ballast zone. A larger Δf(x) indicates more severe high-frequency attenuation and corresponds to greater dielectric loss in the ballast bed.
Applying the above algorithm to the simulated GPR data yields the frequency-domain feature analysis results shown in Figure 8 below.
Figure 8. Frequency-domain feature analysis results: (a) original GPR B-scan, segmented every 5 m; (b) spectral centroid variation. Red represents the original curve; light red represents the average value within this interval.
Figure 8 reveals the influence of ballast heterogeneity and moisture content on the GPR spectral structure. In the clean, dry zone (0–5 m), scattering loss is primarily governed by ballast particle size, and absorption loss is minimal. The centroid frequency fluctuates slightly but maintains a regional average of 1.60 GHz, exhibiting a “high-frequency-rich” spectrum.
As fine contaminants infiltrate and moisture increases in the transition (5–10 m) and heavily fouled (10–15 m) zones, Rayleigh scattering and relaxation absorption intensify. However, it must be objectively acknowledged that the centroid frequency does not exhibit a strict monotonic stepwise decline. Due to strong localized scattering caused by the random geometric distribution of the discrete ballast particles, the curve shows noticeable local fluctuations—most evidently, a temporary frequency rebound in the 5–7 m range. Nevertheless, from a macroscopic perspective, the regional averages (dropping from 1.60 GHz in Zone 1 to approximately 1.59 GHz in Zone 2 and down to 1.58 GHz in Zone 3) still demonstrate a mild overall “redshift” trend as fouling worsens. As propagation depth and moisture increase, high-frequency energy is preferentially dissipated, gradually shifting the spectral centroid toward lower values.
Importantly, the observed volatility indicates that frequency-domain features, while sensitive to changes in scatterer geometry, cannot be solely relied upon for robust condition assessment. This physical reality directly motivates the algorithmic design introduced in Section 4.3: because the frequency feature is susceptible to local scattering noise and lacks a robust monotonic trend, it is intentionally assigned a lower base weight (e.g., 0.3) to serve merely as an auxiliary criterion. By combining it with the highly stable time-domain energy feature, the overall completeness and robustness of the evaluation model are ensured.

4.3. Correlation Modeling Between the Ballast Fouling Index and Track Circuit Electrical Characteristics

Since relative energy attenuation and spectral redshift have different physical units and dynamic ranges, they cannot be directly combined algebraically. To eliminate dimensional effects and enable multi-feature fusion on a common scale [22], we first apply min–max normalization to map both features into a dimensionless interval of [0, 1]. The normalized energy indicator I ^ E ( x ) and normalized frequency indicator I ^ F ( x ) are defined as follows:
I ^ E x = L d B x L m a x , L d B x < L m a x 1 , L d B x ≥ L m a x I ^ F x = Δ f x Δ f m a x , Δ f x < Δ f m a x 1 , Δ f x ≥ Δ f m a x
where L m a x and Δ f m a x are the saturation thresholds. These values are determined based on the physical detection limits of the GPR system and the maximum degradation observed in the 75% heavily fouled zone (in this study, L m a x = 6.0 dB and Δ f m a x = 0.3 GHz). This ensures that the normalization step fully captures the dynamic range of physical deterioration without artificially amplifying background noise.
The sensitivity of energy and frequency features varies across different stages of ballast fouling. As shown in the simulation analysis, during mild to moderate fouling, scattering effects dominate, making the frequency feature more responsive to subtle changes. In contrast, under severe or saturated fouling conditions, conductive losses governed by elevated moisture content become dominant, rendering the energy attenuation feature highly discriminative with a superior signal-to-noise ratio—making it the decisive indicator for assessing deterioration severity.
To enhance the robustness of the assessment model, this paper proposes an energy-dominant adaptive weighting fusion algorithm, improving upon conventional fixed-weight approaches. This algorithm dynamically adjusts the contribution of each feature based on the severity of energy attenuation, yielding a comprehensive fouling index (FI):
F I x = α x · I ^ E x + 1 − α x · I ^ F x
where the dynamic weight coefficient α ( x ) is defined as
α x = w b a s e + 1 − w b a s e · I ^ E x
where w b a s e is the base energy weight. It should be noted that w b a s e is an empirical parameter. In this proof-of-concept study, it is set to 0.7 for demonstration purposes to establish the baseline of the energy-dominant fusion framework. While this value reflects the primary role of time-domain energy attenuation in evaluating ballast fouling, this empirical weight should be further calibrated and optimized using extensive experimental data for practical field applications. Mathematically, substituting Equation (19) into Equation (18) yields a quadratic dependence on the energy indicator I ^ E . This design is intentional. If a traditional fixed-weight linear combination were used (e.g., F I x = 0.7 · I ^ E x + 0.3 · I ^ F x ) , it would fail to accurately capture the rapid deterioration of the ballast bed in late stages. By embedding I ^ E into the dynamic weight α ( x ) , the quadratic relationship acts as a non-linear amplifier. As the fouling becomes severe, it non-linearly magnifies the dominant role of the energy feature. This non-linear escalation aligns with the accelerated degradation behavior of fouled ballast commonly observed in railway engineering studies [2].
This adaptive weighting strategy ensures that when strong attenuation is detected ( I ^ E → 1 ) , the weight coefficient α approaches 1, forcing the model to prioritize the energy feature and thereby avoiding misjudgments caused by instability in frequency estimation under low-signal conditions. In weak-attenuation regions, the frequency feature remains active in the assessment, preserving sensitivity to early-stage fouling.
As discussed in earlier sections, a track circuit is fundamentally a distributed-parameter transmission line system. According to transmission line theory, ballast resistance is the key parameter governing shunt conductance, directly affecting signal transmission loss and shunt sensitivity.
To validate whether the proposed GPR-based comprehensive fouling index can effectively support electrical parameter estimation in the transmission line model, this section correlates the continuously inverted physical fouling state from GPR with the theoretical ballast resistance derived from the Archie model, thereby revealing the intrinsic mechanism by which physical medium degradation drives electrical parameter variation.
As shown in Figure 9, FI and the theoretical ballast resistance R b exhibit a coupling relationship that aligns closely with transmission line theory. In the clean zone, the ballast remains uncontaminated, while GPR signals show low attenuation, and the theoretical R b stays above 1.5 Ω km. This matches the theoretical assumption of minimal leakage current under ideal ballast conditions, confirming that FI accurately reflects the “high-resistance, healthy” state of the track circuit. In the transition zone, as FI increases stepwise due to rising dielectric loss, R b exhibits an order-of-magnitude decline. This validates the physical inference from the transmission line model: increased medium conductivity reduces the shunt impedance. The strict synchronicity between the GPR-observed fouling progression and the electrical resistance drop confirms that FI can serve as a reliable basis for dynamically updating the R b parameter in the transmission line model. In the severely fouled zone, further elevation of FI—combined with signal attenuation analysis—reveals a critical threshold: when R b < 0.5 Ω km, excessive leakage causes the receiver voltage to fall below the operational threshold, potentially triggering a “red light band.” Notably, the GPR-derived FI closely corresponds to this critical electrical threshold, demonstrating its methodological feasibility for evaluating the risk of track circuit ‘red-light band’ failures.
Figure 9. Correlation between FI and theoretical ballast resistance.

4.4. Quantitative Inversion and Error Analysis of Ballast Resistance Based on the Fouling Index

To further validate the applicability of GPR-derived results in track circuit parameter modeling, this paper establishes an exponential “fouling–resistance mapping model”.
As governed by Archie’s law (Equation (4)), the bulk resistivity ρ b of the ballast follows a power-law dependence on water saturation and conductive contaminant fill. Furthermore, the extracted GPR time–frequency features demonstrate a strictly inverse macroscopic trend: as the fouling condition worsens, the comprehensive fouling index steadily increases, while the actual resistance decreases sharply. To map this normalized index ( F I ∈ 0,1 ) to macroscopic track circuit resistance, a negative exponential function is utilized. This function was chosen because it satisfies the physical boundary conditions of the degradation process: it mathematically captures the severe, multi-order-of-magnitude resistance drop while allowing the value to asymptote to a minimum stable threshold in the fully fouled state.
Using the computed FI, we directly invert the predicted ballast resistance R p r e d and compare it against the theoretically true value R t r u e derived from known physical parameters.
R p r e d x = R m a x · e − k · F I x
where the model parameters are calibrated using the clean baseline and the fouling-saturated extreme values.
k = log R m a x log R m i n
The inversion results are shown in Figure 10.
Figure 10. Quantitative inversion of ballast resistance based on the GPR-derived fouling index and comparison with the ground truth.
Figure 10 compares the GPR-inverted ballast resistance R p r e d , obtained using the proposed exponential inversion model, with the theoretical true value R b along the track. Overall, the two curves demonstrate good agreement in their macroscopic trends and magnitude orders.
Specifically, in the 0–5 m clean zone, where the theoretical R b is set to 5.0 Ω km, the inverted resistance remains stable within 4.0–5.0 Ω km with minimal fluctuation. This demonstrates that GPR accurately captures the high insulation quality of clean ballast without false alarms. In the 5–10 m transition zone (30% fouling fill), the theoretical resistance drops stepwise to 1.0 Ω km. The inverted curve shows a rapid decline followed by oscillations in the 1.0–3.0 Ω km range. Notably, it retains fine-scale local variations—reflecting the continuous, heterogeneous nature of real ballast—whereas the theoretical value assumes a uniform regional average. These fluctuations highlight GPR’s superior spatial resolution compared to conventional “segment-based” monitoring, enabling detection of microscale physical changes within the ballast bed. In the severely degraded zone (10–15 m), where theoretical R b plunges to 0.1 Ω km due to high moisture and fouling, the inverted curve responds with high sensitivity, rapidly falling below the critical safety threshold of 0.5 Ω km.
It is expected that the GPR-inverted curve does not exhibit abrupt vertical step boundaries at 5 m and 10 m. While the theoretical resistance is based on idealized uniform blocks (forming a step function), GPR inversion is computed continuously trace by trace. Due to the GPR antenna’s sensing footprint and sliding-window processing, regional transitions naturally manifest as smooth gradients. Furthermore, GPR inversion captures the localized heterogeneity of the ballast particles, leading to local numerical deviations from the idealized theoretical baseline. Despite this, the inverted profile clearly reproduces the three-stage descending trend of ballast resistance, confirming the feasibility of the proposed mapping model.
In summary, the results demonstrate the feasibility of the proposed analytical pipeline, from GPR data to the FI and ultimately to resistance mapping. While local numerical deviations exist, the inverted profile successfully captures the correct order of magnitude and the consistent macroscopic variation trend of the theoretical resistance. By establishing a preliminary correlation between physical fouling and electrical degradation, this proof-of-concept study provides a methodological reference for mitigating the limitations of traditional discrete monitoring, offering a potential perspective for future track circuit condition assessment.
Based on the predicted R p r e d , four risk levels (normal, attention, warning, and severe) are defined, as summarized in Table 3. Risk segments are precisely localized, and targeted maintenance recommendations are provided accordingly.
Table 3. Ballast condition assessment criteria.

5. Conclusions

This paper addresses the critical issue of degraded electrical performance in track circuits on heavy-haul railways caused by ballast fouling. It elucidates the coupling mechanism between the microscopic physical state of the ballast bed and the macroscopic signal transmission characteristics, revealing how fouling and moisture reduce ballast resistance R b and consequently increase transmission loss. Building on this theoretical foundation, we propose a non-contact electrical parameter inversion method based on GPR. By extracting two key features from GPR signals—time-domain relative energy attenuation and frequency-domain spectral redshift—and fusing them via an adaptive weighting algorithm, we construct a comprehensive fouling index that accurately quantifies physical deterioration. Furthermore, we establish a quantitative mapping model from FI to R b , enabling continuous inversion of ballast resistance along the entire railway line using GPR scan data. The inverted results not only precisely reproduce the stepwise decline of R b with increasing fouling severity but also confirm that the FI alarm threshold corresponds to the critical safety limit of R b = 0.5 Ω km. Compared to traditional qualitative GPR interpretations, the primary scientific contribution of this work lies in establishing a quantitative mapping framework between macroscopic electromagnetic features and the physical electrical resistance of track circuits. By proposing the adaptive multi-feature fusion algorithm, this study successfully mitigates the volatility of localized scattering, offering a preliminary methodological framework for quantitative fouling evaluation. However, several limitations must be acknowledged. The current proof-of-concept framework relies on a standardized stochastic numerical model with fixed gradations and a specific high-moisture fouling type. In reality, heavy-haul railways exhibit immense environmental variability. Therefore, the immediate future research will focus on experimental verification.

Author Contributions

Conceptualization, L.F. and Z.X.; methodology, L.F. and Z.X.; software, L.F. and J.L.; investigation, L.F. and J.L.; writing—original draft preparation, J.L. and Z.X.; writing—review and editing, Z.X. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data presented in this study are available in the article.

Acknowledgments

We express our gratitude to Hangzhou Institute of Technology (Xidian University) for providing the experimental platforms and technical support essential for this research. We also thank the laboratory staff for their valuable guidance and assistance.

Conflicts of Interest

Author Liqiang Fu was employed by the company “China Energy Shuohuang Railway Development Co., Ltd., China”. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
GPRGround-Penetrating Radar
FDTDFinite-Difference Time-Domain
FIFouling Index
R b Ballast Electrical Resistance
RMSRoot Mean Square
I ^ E ( x ) Normalized Energy Indicator
I ^ F ( x ) Normalized Frequency Indicator

References

  1. Solla, M.; Pérez-Gracia, V.; Fontul, S. A Review of GPR Application on Transport Infrastructures: Troubleshooting and Best Practices. Remote Sens. 2021, 13, 672. [Google Scholar] [CrossRef] [Scilit]
  2. Lazorenko, G.; Kasprzhitskii, A.; Khakiev, Z.; Yavna, V. Dynamic behavior and stability of soil foundation in heavy haul railway tracks: A review. Constr. Build. Mater. 2019, 205, 111–136. [Google Scholar] [CrossRef] [Scilit]
  3. Qian, Z.; Xiao, H.; Kong, C.; Chen, Z.; Wei, S. Investigation of dynamic mechanical behaviour of railway ballast under a 30t moving axle load. Int. J. Rail Transp. 2025, 1–29. [Google Scholar] [CrossRef] [Scilit]
  4. Yang, W.; Gao, J.; Xu, Z. A rapid detection method for coal dust thickness in heavy-haul railway ballast based on time and frequency domain response characteristics from GPR signal. Sci. Rep. 2026, 16, 2103. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Xiong, Q.; Yang, S.; Liu, C. Simulation on adjacent line mutual interference of high-speed railway track circuit. MATEC Web Conf. 2022, 355, 02019. [Google Scholar] [CrossRef] [Scilit]
  6. Wang, C.; Yang, S.; Liu, C. Automatic weighted ensemble learning for ballast resistance estimation driven by vehicle-ground information fusion. Eng. Appl. Artif. Intell. 2025, 162, 112406. [Google Scholar] [CrossRef] [Scilit]
  7. Artagan, S.S.; Borecky, V. Advances in the nondestructive condition assessment of railway ballast: A focus on GPR. NDT E Int. 2020, 115, 102290. [Google Scholar] [CrossRef] [Scilit]
  8. Daniels, D.J. Ground Penetrating Radar, 2nd ed.; The Institution of Engineering and Technology: London, UK, 2004. [Google Scholar]
  9. Hill, R.J.; Carpenter, D.C. Rail track distributed transmission line impedance and admittance: Theoretical modeling and experimental results. IEEE Trans. Veh. Technol. 1993, 42, 225–241. [Google Scholar] [CrossRef] [Scilit]
  10. Xing, Y.; Li, W.; Liu, Z.M. Research on the performance of heavy-haul rail breakage detection using track circuit. Transp. Saf. Environ. 2020, 2, 292–304. [Google Scholar] [CrossRef] [Scilit]
  11. Zhao, L.; Guo, J.; Li, H.; Liu, W. The simulation analysis of influence on jointless track circuit signal transmission from compensation capacitor based on transmission-line theory. In Proceedings of the 2009 3rd IEEE International Symposium on Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications, Beijing, China, 27–29 October 2009; pp. 1113–1118. [Google Scholar] [CrossRef] [Scilit]
  12. Archie, G.E. The electrical resistivity log as an aid in determining some reservoir characteristics. Trans. AIME 1942, 146, 54–62. [Google Scholar] [CrossRef] [Scilit]
  13. Xiang, N.; Wang, Y.; Oleiwi, H.M.; Chadwick, E.; Yao, G.; Augusthus-Nelson, L.; Chen, X.; Shabalin, I. Modelling the electrical resistivity of concrete with varied water and chloride contents. Mag. Concr. Res. 2020, 72, 552–563. [Google Scholar] [CrossRef] [Scilit]
  14. Tosti, F.; Ferrante, C. Using ground penetrating radar methods to investigate reinforced concrete structures. Surv. Geophys. 2020, 41, 485–530. [Google Scholar] [CrossRef] [Scilit]
  15. Warren, C.; Giannopoulos, A.; Giannakis, I. gprMax: Open source software to simulate electromagnetic wave propagation for Ground Penetrating Radar. Comput. Phys. Commun. 2016, 209, 163–170. [Google Scholar] [CrossRef] [Scilit]
  16. Benedetto, A.; Tosti, F.; Ciampoli, L.B.; D’Amico, F. An overview of ground penetrating radar signal processing techniques for road inspections. Signal Process. 2017, 132, 201–209. [Google Scholar] [CrossRef] [Scilit]
  17. Kong, Q.; Ye, S.; Liang, X.; Li, X.; Liu, X.; Fang, G.; Si, G. A clutter removal method based on the FK domain for ground penetrating radar in complex scenarios. Remote Sens. 2024, 16, 935. [Google Scholar] [CrossRef] [Scilit]
  18. Warren, C.; Giannopoulos, A. Creating finite-difference time-domain models of commercial ground penetrating radar antennas using Taguchi’s optimization method. Geophysics 2011, 76, G37–G47. [Google Scholar] [CrossRef] [Scilit]
  19. Cui, X.; Ren, X.; Xu, H.; Lin, C.; Li, Q.; Qin, J.; Gao, Y. Energy-based analysis of the effect of fastener failure on ballast bed under train load. J. Railw. Sci. Technol. 2025, in press. [Google Scholar] [CrossRef] [Scilit]
  20. Balanis, C.A. Advanced Engineering Electromagnetics, 2nd ed.; John Wiley & Sons: Hoboken, NJ, USA, 2012. [Google Scholar]
  21. Zatar, W.; Hua, X.; Chen, G.; Nguyen, H.; Nghiem, H. Evaluating the properties of railway ballast using spectral analysis of ground penetrating radar signal based on optimized variational mode decomposition. Adv. Civ. Eng. 2022, 2022, 2840318. [Google Scholar] [CrossRef] [Scilit]
  22. Singh, D.; Singh, B. Investigating the impact of data normalization on classification performance. Appl. Soft Comput. 2020, 97, 105524. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.