Skip to Content
Applied SciencesApplied Sciences
  • Article
  • Open Access

29 November 2026

19 Pages

Pressure-Response-Based Online Cascaded System for Detecting and Localizing Unreported Leaks in Water Distribution Networks

,
and
School of Automation and Electrical Engineering, University of Jinan, Jinan 250022, China
*
Author to whom correspondence should be addressed.
Appl. Sci.2026, 16(23), 11852;https://doi.org/10.3390/app162311852 
(registering DOI)
This article belongs to the Section Civil Engineering

Abstract

Pressure responses induced by unreported leaks are relatively weak and can be readily masked by demand fluctuations and measurement errors, complicating online leak detection and localization. Most existing detection and localization methods are designed for offline analysis and lack mechanisms for alarm confirmation, window configuration, and localization-call control during continuous online monitoring. To address this gap, this study develops a pressure-response-based online cascaded system. The system uses a consecutive-confirmation rule to reduce false alarms and configures detection and localization windows separately based on offline screening criteria. After an alarm is confirmed, the localization model is called to output regional- or node-level candidate locations. The system was evaluated on four networks: L-town, Modena, Hanoi, and FOWM. Alarm confirmation rates exceeded 92% in all four networks. Top-1 hit rates were 48.52–91.46%, and Top-3 hit rates were 70.63–99.65%. Relative to the all-window localization reference count, localization-model calls were reduced by 41.88–62.33%. These results show that the system can confirm leak alarms and output candidate locations during continuous monitoring, reduce the computational burden of repeated localization inference, and support targeted field investigations of unreported leaks.

1. Introduction

Leakage is one of the major sources of non-revenue water and a key issue in reducing water losses and managing water distribution networks [1,2,3]. Unreported leaks may remain undetected for extended periods because their pressure effects overlap with demand variations and measurement uncertainty. Online monitoring generally requires both alarms and location estimates that can guide field investigations [4,5]. Transient test-based techniques (TTBTs) use pressure waves propagating through pipes and the resulting responses to obtain information on leak location and magnitude. Xu and Karney [6] reviewed the theory and methods of transient fault detection. Brunone et al. [7] reviewed the associated laboratory and field tests and discussed the effects of network layout, transient excitation, and operating conditions on the test responses.
In intelligent monitoring research, Ulhaq et al. [8] compared the Faster region-based convolutional neural network (Faster-RCNN) and You Only Look Once version 3 (YOLOv3) models for target detection in multi-sensor images, and Siddique et al. [9] incorporated physical information into statistical bearing fault diagnosis. Pressure-response studies in water distribution networks combine pressure observations with hydraulic predictions, using deviations of monitored pressures from leak-free predictions to represent leak-induced disturbances. Jun and Lansey [10] represented these deviations as pressure-response images for convolutional neural network (CNN) detection; Jun et al. [11] accumulated spatial pressure information over time and used a three-dimensional CNN (3D CNN) for leak detection and localization. Zhang et al. [12] used a parallel CNN–long short-term memory (LSTM) architecture with cross-modal attention (PCLA) to fuse pressure-response heat maps and time series for binary detection of small-scale leakage. La Cognata et al. [13] further discussed the conditions for applying pressure-response methods in terms of demand information, measurement noise, and assumptions about the leak-free reference.
Mohammed et al. [14] used hydraulic modeling and classification for leak detection and localization. Soldevila et al. [15] combined sequential monitoring of inlet flow, statistical confirmation, and classification-based localization. Daniel et al. [16] proposed a sequential pressure-based approach that combined data-driven leak identification with model-based localization. Tyagi et al. [17] proposed a two-stage data-driven model, Min et al. [18] proposed a two-phase model for leak detection and localization, and Adraoui et al. [19] combined wavelet decomposition and machine learning to organize detection and localization. Capelo et al. [20] used 24 h pressure records for burst localization and sizing and discussed the need to shorten input windows for near-real-time applications. Travaš et al. [21] triggered optimization-based localization when detection conditions were met during continuous monitoring, and Liu et al. [22] combined online change-point detection with leak-sensitivity modeling. Building on these studies, continuous online monitoring also requires explicit alarm-confirmation rules, separate detection and localization window configurations, and defined conditions for calling the localization model.
This study develops a pressure-response-based online cascaded system that uses a consecutive alarm-confirmation rule and configures detection and localization windows separately. The detector uses the PCLA architecture of Zhang et al. [12]. The localizer reuses its parallel feature-extraction and cross-modal attention structures and provides network-specific multiclass outputs for regions or nodes. The system calls the localization model when an alarm is confirmed and a localization window is available, providing regional- or node-level candidate locations. Alarm confirmation, alarm delay, Top-1 and Top-3 localization hit rates, spatial error, and localization-model calls were evaluated in four networks: L-town, Modena, Hanoi, and FOWM. Continuous alarm and localization performance was also examined through a one-year hydraulic replay of events from the Battle of the Leakage Detection and Isolation Methods (BattLeDIM).

2. Materials and Methods

2.1. Pressure-Response Inputs and Classifiers

The pressure response, denoted by ΔP, is the difference between the leak-free pressure predicted by the hydraulic model and the monitored pressure. For classification, both the detector and the localizer use the absolute value of the pressure response as input. Data for each controlled scenario were generated in three steps.
(1) Hydraulic operating conditions. This study assumes an ideally calibrated hydraulic model. Gaussian perturbations with a standard deviation of 10% were applied to nodal demand, and uniform perturbations within ±10% of the baseline value were applied to each pipe-roughness coefficient to generate different operating conditions. The hydraulic model calculates the leak-free reference pressure Ppred(t) from nodal demand and operating settings at each time step.
(2) Normal-condition data generation. Simulated pressure measurements under normal conditions were obtained by adding Gaussian measurement error to Ppred(t). The error had a standard deviation of 0.05 m:
P normal t = P pred t + ε
Here, ε∼N(0,0.052) is the Gaussian measurement error, drawn separately for the normal and leakage observations in Equations (1) and (3). Pnormal(t) is the simulated pressure measurement under normal conditions. The normal-condition pressure response is
Δ P normal t = P pred t − P normal t
(3) Leakage-condition data generation. The demand and roughness perturbations from Step (1) were retained. A leak was introduced at a randomly selected node. The hydraulic model recalculated pressure at every node. The recalculated nodal pressures are denoted by P pred ′ t . Simulated pressure measurements under leakage conditions were obtained by adding measurement error ε to the recalculated pressures:
P leak t = P pred ′ t + ε
Here, Pleak(t) is the simulated pressure measurement under leakage conditions. The leakage-condition pressure response is
Δ P leak t = P pred t − P leak t
Within the same simulated operating condition, the leak-free reference pressures and the normal and leakage observations use the same demand and roughness settings. The normal-condition pressure response is, therefore, the absolute value of measurement error, whereas the leakage-condition pressure response results from the pressure difference caused by leakage and measurement error. The two types of responses obtained from Equations (2) and (4) are used to construct the heat-map and time-series inputs.
Each rolling-window pressure response is represented in two forms. The CNN heat-map input uses the maximum pressure response at each demand node within the window. These values are mapped to a regular G × G grid, where G is the number of grid cells along each heat-map dimension, with the values listed in Table 1. The grid values are then normalized to [0, 1]. The LSTM sequence input retains the complete pressure-response time series of all demand nodes within the same window. Online tests for the four controlled networks used all demand nodes as inputs. The BattLeDIM replay used pressure inputs from 782 demand nodes. The mean pressure response was calculated by averaging the pressure responses across these 782 demand nodes at each time step.
Table 1. Network characteristics and localization settings.
The detector used the PCLA architecture proposed by Zhang et al. [12] (Figure 1a). The CNN and LSTM branches extracted features from the pressure-response heat map and time series, respectively, and these features were then fused through cross-modal attention. The fused features then passed through batch normalization and dropout before entering a fully connected classification layer. The localizer used the same parallel feature-extraction and cross-modal-attention fusion structure. The binary output layer was replaced with a network-specific multiclass layer.
Figure 1. PCLA architecture, detection and localization outputs, and online cascaded flow. PCLA denotes a parallel convolutional neural network–long short-term memory architecture with cross-modal attention.
The two classifiers were trained independently with cross-entropy loss and the Adam optimizer. The batch size was 32. The initial learning rates were 0.003 for the detector and 0.005 for the localizer. Binary F1 is the harmonic mean of precision and recall. Model checkpoints were selected by validation-set F1. Binary F1 was used for detection, and support-weighted multiclass F1 was used for localization. The detector outputs probabilities for the normal and leakage states. In offline evaluation, the class with the higher output probability determines the window class. The localizer outputs probabilities for network-specific region or node classes (Figure 1b). The two classifiers are connected through the online cascaded flow shown in Figure 1c. The call rules are described in Section 2.2.

2.2. Online Cascaded System and Localization-Call Rules

The detection and localization window lengths are denoted by Wdet and Wloc, respectively. Every 5 min, the online cascaded system updates the leakage probability using the most recent Wdet pressure-response window. The leakage probability at the kth update is denoted by pleak(k). Under the rule of three consecutive confirmations used in this study, a single positive prediction does not constitute an alarm.
An alarm is confirmed when the leakage probabilities at three consecutive 5 min update times are all strictly greater than the fixed threshold τ for the corresponding network. The thresholds were set empirically to 0.50 for L-town and Modena and 0.90 for Hanoi and FOWM. The offline probability-threshold analyses for the four networks are presented in Tables S4–S7 of the Supplementary Materials. False alarms and alarm delays under different numbers of consecutive confirmations in the one-year L-town decision sequence are presented in Tables S8 and S9.
During system operation, the first confirmed alarm in the monitoring period initiates the localization wait. When Wloc > Wdet, an additional configuration wait is imposed. This wait ensures that the localization window at the end of the wait has the same starting time as the detection window at the alarm time. After the wait, the localization model is called when the consecutive-confirmation criterion is satisfied and a complete localization window is available.
For online evaluation, the first confirmed alarm after the true leak onset is treated as a valid alarm. The valid-alarm time, Talarm, is used to calculate alarm delay and subsequent localization metrics included in the evaluation. A confirmed alarm before leak onset is counted as a scenario-level false alarm. The localization waiting time is
T wait = max ( 0 , W loc − W det )
Window lengths are reported in hours in figures and tables. They are converted to minutes before substitution into the equations in this section. Thus, Wdet, Wloc, Talarm, and Twait are all expressed in minutes in the equations. The localization configuration time in online evaluation is defined as
T cfg = T alarm + T wait
Only localization outputs formed at Tcfg or later are included in the online statistics. Each call uses a rolling window of length Wloc ending at the current update time. The localization model outputs probabilities for regions or nodes. Classes are ranked in descending order of output probability. The first k classes form the Top-k output. Online Top-k statistics use only the first formal localization output. Later outputs are not counted again. A scenario is recorded as a Top-k hit when the true region or node is included in that output. Online results are reported for k = 1 and k = 3.
The rolling detection, alarm confirmation, and localization-call procedure is shown in Figure 2. The example uses Wdet = 1 h and Wloc = 3 h.
Figure 2. Pressure-response rolling windows and confirmed-alarm/localization-call rules.
The all-window localization reference count, Ncontinuous, is used to compare the number of localization calls. For leakage scenario i, pressure is recorded over a 30 h monitoring period at 5 min intervals, including both endpoints. The number of pressure time points is, therefore, Mi = 361. A localization input window contains nloc = Wloc/Δt time points, where Wloc is expressed in minutes and Δt = 5 min. The all-window reference count for this scenario is
N i = M i − n loc + 1
This definition does not depend on the detection state. All complete localization windows that can be formed during the online monitoring period are counted. The all-window reference count for the same set of leakage scenarios is
N continuous = ∑ i N i
The quantity Ncascade denotes the number of localization calls included in the evaluation statistics for the same leakage scenarios. The localization-call reduction rate is defined as
R call = 1 − N cascade N continuous

2.3. Leak Model and Spatial Evaluation

Controlled leakage scenarios were generated with the pressure-dependent orifice model in the Water Network Tool for Resilience (WNTR). Leak flow varies with pressure head:
q l t = C d A 2 gH t
Here, ql(t) is the leak flow rate at time t, in m3/s. The orifice discharge coefficient is Cd. The leak area is A, in m2. Gravitational acceleration is g, in m/s2. The pressure head at the leak node is H(t), in m. The simulations used Cd = 0.75 and g = 9.81 m/s2.
Leak areas were selected to represent a target reference-flow range of 1.0–3.0 L/s at the reference pressure head. This range includes the 25 gpm reference flow specified in the American Water Works Association (AWWA) M36 manual for unreported leaks and breaks on mains or pipelines. The reference flow is approximately 1.58 L/s at a reference pressure of 70 psi [23] (Table 3-22, p. 102). The reference-flow range was converted into network-specific leak-area ranges using Href, the mean normal-condition pressure head at candidate leak nodes in each network. The definitions of unreported leaks, leak-area conversion, and reference leak-to-demand ratios are provided in Supplementary Methods (“Leak-Area Conversion for Controlled Scenarios”). The network-specific conversion parameters are listed in Table S1. Actual leak flow remained dependent on local hydraulic conditions during simulation. Therefore, the same reference-flow range corresponded to different leak-to-demand ratios among the networks.
The localization level was defined separately for each network. L-town and Modena used regional classes. Hanoi and FOWM used single-node classes and were assessed at the node level. The average shortest-path distance (ASD) measures the topological distance between predicted and true locations. For regional localization, the region with the highest output probability is selected as the prediction. The predicted region is represented by its center node. For sample i, let vi denote the true leak node, ai the true region, a ^ i the predicted region, and c a ^ i the center node of the predicted region. The sample-level error is
e i = 0 , a ^ i = a i d ( v i , c a ^ i ) , a ^ i ≠ a i
The ASD is
ASD = 1 N ∑ i = 1 N e i
Here, N is the number of localization samples included in the assessment. The function d(⋅) is the pipe-length-weighted shortest-path distance along the network topology. For node-level localization, ASD is calculated directly as the shortest-path error between the predicted node and the true leak node. For regional localization, the pipe-length-weighted shortest-path distance from the true leak node to the center node of the highest-probability region is also calculated for each sample, in m, including samples with a correctly classified region.

2.4. Networks and Evaluation Protocol

Four benchmark water networks were studied: L-town, Modena, Hanoi, and FOWM. L-town was obtained from the BattLeDIM benchmark [24]. Modena, Hanoi, and FOWM were obtained from the University of Kentucky Water Distribution System Research Database [25]. WNTR was used to read EPANET-compatible models, apply demand perturbations, and simulate leak outflow with the pressure-dependent orifice model [26,27]. Hydraulic simulations were performed using WNTRSimulator. Nodal demand was handled with demand-driven analysis. Hydraulic calculations and pressure reporting used a 5 min time step.
L-town and Modena are distribution-oriented networks. Hanoi and FOWM are transmission-oriented networks. The four networks differ in scale, topology, pipe diameter, operating pressure, and localization level. Results were, therefore, reported separately for each network. Table 1 summarizes the network characteristics and localization settings. In the table, Qsys is the sum of nodal base demands in the EPANET input file before demand-pattern multipliers are applied. Dsys is the system average pipe diameter. Lsys is the total pipe length. These three baseline values were obtained from Zhang et al. [12]. The remaining parameters were determined from the hydraulic models and localization settings.
The node counts in Table 1 include boundary nodes such as reservoirs and tanks. Boundary nodes were excluded from the candidate leak nodes in every network. The numbers of demand nodes used as pressure inputs were 782, 268, 31, and 44 for L-town, Modena, Hanoi, and FOWM, respectively. L-town had three boundary nodes, consisting of two reservoirs and one tank. Modena had four reservoirs; Hanoi and FOWM each had one reservoir.
Figure 3 shows the network topologies and localization settings. Colored filled areas denote leak regions for regional localization. For regional localization, red stars mark regional center nodes; for node-level localization, they mark the corresponding nodes. Pipe width indicates the pipe-diameter class. In the legend, squares, diamonds, triangles, and hexagons denote reservoirs, tanks, pumps, and valves, respectively.
Figure 3. Network topologies and localization classes.
Controlled scenarios were generated as described in Section 2.1. Leak areas for offline samples were drawn from the network-specific ranges. Leak locations across the offline samples covered all candidate nodes in each network. Regional tasks used balanced sampling across regions.
Leak onset times in offline scenarios were selected as integer hours from 0 to 23 h. Each simulation lasted 30 h. Samples with different onset times were generated for the same leak node. Before sample generation, scenario identifiers were assigned to the training, validation, and test sets in proportions of 70%, 15%, and 15%, respectively. Normal and leakage samples associated with the same identifier remained in the same subset. The detection test sets contained 30,000, 21,000, 12,000, and 15,000 samples for L-town, Modena, Hanoi, and FOWM, respectively.
The training set was used to learn model parameters, and validation-set F1 was used to select the model weights for each candidate window. The offline test set was used to calculate detection F1 and false-positive rate (FPR), and localization Top-3 hit rate and ASD, for window screening. Leakage samples were used for localization training and evaluation. The numbers of localization test samples for L-town, Modena, Hanoi, and FOWM were 15,000, 10,500, 6000, and 7500, respectively. Table 2 reports the results for each recommended window on the offline test set used for screening. Offline windows were extracted starting at the known leak onset, whereas online evaluation used rolling windows updated every 5 min. The candidate detection-window lengths were 0.25 h, 0.5 h, 0.75 h, 1 h, 2 h, and 3 h, and the candidate localization-window lengths were 0.25 h, 0.5 h, 0.75 h, 1 h, 2 h, 3 h, 4 h, 5 h, and 6 h.
Table 2. Windows selected by offline screening and their test-set performance.
Detection windows were screened with test-set F1 and FPR. Localization windows were screened with test-set Top-3 hit rate and ASD. A candidate knee point was first identified on the composite-score curve. The shortest window satisfying the task-specific constraint was then selected from the candidate window at the knee and the longer candidate windows. The normalized scores, constraints, and fallback rules are provided in Supplementary Methods (“Offline Screening Criteria for Detection and Localization Windows”). Window-screening results under varying score weights and screening constraints are reported in Supplementary Table S10.
Offline detection metrics included accuracy, recall, F1, and FPR. Each individual detection window was one statistical unit. Recall is the proportion of actual leakage windows detected correctly. Accuracy is the proportion of correctly classified windows. FPR is the proportion of normal windows misclassified as leakage.
Offline localization metrics included Top-1, Top-3, and Top-5 hit rates and the ASD defined in Equation (12). For each localization test window, candidate classes were ranked in descending order of model output probability. The Top-k hit rate is the proportion of localization samples for which the true leak location appears among the k highest-ranked candidate classes. Top-5 was used for offline window comparison. Online results report Top-1 and Top-3 only.
After model and window selection, the online cascaded system was evaluated using rolling scenarios in terms of alarm confirmation rate, alarm delay, localization hit rate, and localization-model calls. Table 3 reports the online results for each network per 5000 leakage scenarios and 5000 no-leak scenarios. Leak locations were sampled evenly across localization classes, and the center node of each region was used consistently for regional localization.
Table 3. Online test results.
In the online scenarios, the fixed leak areas were 0.00006993 m2, 0.00009489 m2, 0.00007352 m2, and 0.00006367 m2 for L-town, Modena, Hanoi, and FOWM, respectively. These areas were converted from the mean normal-condition reference head Href for each network and a reference leak flow of approximately 1.58 L/s. The source of the reference value is given in Section 2.3 and Supplementary Methods. The instantaneous leak flow ql(t) in the simulations is calculated using Equation (10) from the local pressure head H(t) at the leak node and, therefore, varies with time and leak location.
Leakage scenarios were evaluated in terms of alarm confirmation rate, alarm delay, and Top-k localization hit rate. The alarm confirmation rate is the proportion of leakage scenarios that formed a valid alarm during the 30 h monitoring period:
R conf = N conf N leak
Here, Nleak is the total number of leakage scenarios. Nconf is the number of scenarios that satisfied the confirmation criterion in Section 2.2 after the true leak onset. For each scenario with a valid alarm, alarm delay is the difference between Talarm and the true leak-onset time. Table 3 reports the median alarm delay across all scenarios with a valid alarm. The denominator of the online Top-k hit rate is the number of scenarios that produced a first formal localization output. The numerator is the number of those scenarios whose first formal localization output was a Top-k hit.
The leakage scenarios used for the supplementary statistics were selected from the complete set of simulated scenarios used for online evaluation. The scenario counts are presented in Tables S2 and S3. The proportion of correctly detected and localized scenarios uses all leakage scenarios in this supplementary set as its denominator and the number of scenarios with a Top-1 hit in the first formal localization output after leak onset as its numerator. Scenarios in which no leak was detected or no formal localization output was produced are included in the denominator. The delay to the first formal localization output is the time difference between the true leak onset and the first formal localization output and is calculated only for scenarios in that set that produced such an output. The proportion of correctly detected and localized scenarios and the delay to the first formal localization output are reported in Tables S2 and S3, respectively.
Online false alarms were counted at both the detection-window and scenario levels. The window-level FPR, FPRwin, uses the total number of complete rolling detection windows in no-leak scenarios as its denominator. The numerator is the number of those windows that satisfy the consecutive-confirmation criterion. For the offline FPR reported in Table 2, a normal test window is classified as leakage when leakage has the higher model output probability. Online FPRwin uses the fixed threshold and rule of three consecutive confirmations in Section 2.2.
When consecutive confirmation is removed while the same probability threshold is retained, the window-level FPR is denoted by FPR win ′ . Scenario-level false alarms are counted in two situations: a confirmed alarm in a no-leak scenario, or a confirmed alarm before the true leak onset in a leakage scenario. A scenario is included in the false-alarm count if either situation occurs. The scenario-level false-alarm proportion Rfa uses 10,000 online scenarios per network as the denominator, comprising 5000 leakage scenarios and 5000 no-leak scenarios. When consecutive confirmation is removed and a single-window positive prediction is used, the corresponding proportion is denoted by R fa ′ .
The six leakage scenarios in the BattLeDIM benchmark were reconstructed according to the scenario settings and validation framework reported by Rajabi et al. [28]. The replay also followed the treatment of these scenarios described by Zhang et al. [12]. The replay used the L-town detection window of 1 h and localization window of 2 h selected in Table 2. The replay results in Table 4 use the rule of three consecutive confirmations described in Section 2.2. Annual false alarms, event detection, and alarm delays were also compared for 1–10 consecutive confirmations using the same full-year pressure inputs, detection model, detection window, and probability threshold. The results are reported in Tables S8 and S9 of the Supplementary Materials.
Table 4. Online cascaded-system replay results for the reconstructed L-town BattLeDIM scenarios.

3. Results and Discussion

3.1. Window Screening and Performance of the Online Cascaded System

The detection- and localization-window screening results are shown in Figure 4 and Figure 5. In Figure 4, the left axis shows accuracy, F1 score, and recall, whereas the right axis shows FPR. The vertical dashed lines mark the recommended windows. The complete screening criteria are provided in Supplementary Methods (“Offline Screening Criteria for Detection and Localization Windows”).
Figure 4. Detection-window screening results. FPR denotes the false-positive rate.
Figure 5. Localization-window screening results. ASD denotes average shortest-path distance.
As the detection window increased, accuracy, F1 score, and recall generally increased, whereas FPR generally decreased. The recommended detection window was 1 h for both distribution-oriented networks, L-town and Modena. The recommended windows were 3 h for Hanoi and 2 h for FOWM. The transmission-oriented networks required longer detection windows. Their FPR values nevertheless remained higher than those of the distribution-oriented networks at the recommended settings.
In Figure 5, the left axis shows Top-1, Top-3, and Top-5 hit rates, whereas the right axis shows ASD. For a 2 h window, the distribution-oriented networks achieved Top-3 hit rates of 98.81–100.00% and ASD values of 33.3–72.9 m. The recommended localization windows for the transmission-oriented networks were 4–5 h. Their Top-3 hit rates ranged from 75.47% to 90.40%, and their ASD values ranged from 540.6 to 692.5 m. For the distribution-oriented networks, Top-3 hit rates were nearly saturated at windows of 2 h or longer. Further increases in window length, therefore, yielded limited gains in candidate coverage. ASD generally decreased as the window length increased. In the transmission-oriented networks, Top-3 hit rates continued to improve and ASD progressively decreased with longer windows. A longer pressure-response history, therefore, continued to improve node-level localization. The recommended localization windows were selected using the test-set composite score subject to the Top-3 constraint (Supplementary Methods (“Offline Screening Criteria for Detection and Localization Windows”)).
Table 2 summarizes the recommended windows selected by offline screening and their test-set performance. The online cascaded system used these recommended windows. Table 3 reports its alarm, localization, and model-call results under rolling monitoring and consecutive confirmation. Alarm confirmation rates exceeded 92% in all four networks. Median alarm delays were 10–40 min in the distribution-oriented networks and 75–145 min in the transmission-oriented networks. With the number of scenarios producing a first formal localization output as the denominator, Top-1 hit rates were 89.46–91.46% in the distribution-oriented networks and 48.52–54.50% in the transmission-oriented networks. The distribution-oriented networks had shorter alarm delays and higher Top-1 hit rates, whereas the transmission-oriented networks showed the opposite pattern. This difference is consistent with the better detection and localization performance achieved by the distribution-oriented networks at shorter windows in Figure 4 and Figure 5. The supplementary statistics included 3960, 2688, 3720, and 4224 leakage scenarios for L-town, Modena, Hanoi, and FOWM, respectively. With all leakage scenarios included in the statistics for each network as the denominator, the proportions of correctly detected and localized scenarios were 91.46%, 82.07%, 50.35%, and 42.16%, respectively, as reported in Table S2. The delay to the first formal localization output was calculated only for supplementary scenarios that produced a first formal localization output in each network. The median delays for L-town, Modena, Hanoi, and FOWM were 100, 70, 205, and 255 min, respectively, and their distributions are reported in Table S3.
Consecutive confirmation reduced the window-level FPR and scenario-level false-alarm proportion in all four networks. The values of FPRwin were 0.12%, 0.01%, 2.46%, and 3.23% for L-town, Modena, Hanoi, and FOWM, respectively; without consecutive confirmation, the corresponding values of FPR win ′ were 0.45%, 0.06%, 3.27%, and 4.56%. The values of Rfa were 4.03%, 0.67%, 21.56%, and 29.06% across the four networks, respectively, compared with values of R fa ′ of 8.14%, 5.23%, 43.69%, and 46.01% without consecutive confirmation. Consecutive confirmation reduced the scenario-level false-alarm proportions in Hanoi and FOWM by 50.65% and 36.84%, respectively, relative to the values without consecutive confirmation. In their multi-network CNN detection study, Jun and Jung [29] discussed the difficulty of distinguishing normal and leakage pressure responses in Hanoi and FOWM and noted that weak leak responses are susceptible to demand variations and measurement errors. Frequent false alarms may increase the workload for alarm verification and reduce operators’ trust in system alarms. Offline classification results at different probability thresholds are reported in Tables S4–S7 of the Supplementary Materials. False alarms, numbers of detected events, and alarm delays for different numbers of consecutive confirmations in the one-year L-town replay are reported in Tables S8 and S9.
Relative to the all-window reference count, localization-model calls included in the evaluation decreased by 41.88–62.33% across the four networks. Calculated per 5000 leakage scenarios, the localization-call counts were 982,294, 866,051, 591,434, and 599,335 for L-town, Modena, Hanoi, and FOWM, respectively. The corresponding all-window reference counts were 1,690,000, 1,690,000, 1,570,000, and 1,510,000. L-town and Modena used the same detection window, localization window, and all-window reference count. Their localization-call reduction rates were 41.88% and 48.75%, respectively, a difference of 6.88 percentage points. The reduction in localization calls depends on whether the consecutive-confirmation condition continues to be satisfied and whether a complete localization window is available after alarm confirmation. In the supplementary online simulations, the mean detection-stage and localization-stage processing times per operation were 140.7–304.9 ms and 137.6–317.5 ms, respectively, including input construction, model inference, and the corresponding processing operations. The system update interval is 5 min. Mean processing times per stage operation are reported in Table S11 of the Supplementary Materials. Cumulative localization processing time is obtained by multiplying the number of localization calls included in the evaluation by the mean localization-stage processing time per operation. The all-window localization reference processing time is obtained by multiplying the all-window localization reference count by the same mean processing time. The results are reported in Table S12. All detection windows, actual localization calls, and cumulative detection and localization processing times for leakage and no-leak scenarios are calculated per 5000 leakage scenarios and 5000 no-leak scenarios and reported in Table S18. Actual localization calls include calls triggered by false alarms. Cumulative processing times are calculated separately for the detection stage and actual localization stage in each scenario class and then summed. The number of parameters, forward-pass inference time for a single sample on a central processing unit (CPU), and peak process working set of the selected models are reported in Table S13. L-town and Modena achieved higher Top-1 and Top-3 hit rates than Hanoi and FOWM. The four networks differ in the ratio of reference leak flow to system base demand, localization level, topology, number of classes, windows, and alarm thresholds. These settings jointly affect cross-network performance comparisons. The ratios and leak-area conversions are provided in the Supplementary Materials.

3.2. Spatial Localization Outputs

Offline localization ASD values at the recommended localization windows are reported in Table 2. In node-level tasks, each candidate class corresponded to one node. In regional tasks, nodes within the same region shared a class. Numerical differences between the two task types, therefore, reflected both localization level and the spatial scale used for evaluation. L-town used a 33-region mapping constructed from the 33 pressure-sensor locations in the BattLeDIM benchmark [24], with each demand node assigned a localization class according to its region. Both the controlled online evaluation and the one-year hydraulic replay used pressure inputs from all 782 demand nodes. Modena uses regional localization, and its leak-region construction was informed by the hydraulic-simulation and regional-partitioning approach of Zhang et al. [30]. In this study, 56 regions were constructed based on pressure-response similarity, region size, and topological connectivity, and the resulting region mapping was used to define the subsequent localization classes. The pressure-response matrix and the center nodes of the regions are defined in the Supplementary Methods. Selection of the number of regions is shown in Figure S1. The final layout is shown in Figure S2. In offline evaluation at the selected localization windows, the mean distances from the true leak node to the center node of the predicted region were 211.3 m for L-town and 197.9 m for Modena. The distance distributions and the total pipe length within the union of the Top-3 candidate regions in L-town are reported in Tables S14 and S15 of the Supplementary Materials, respectively. A demand node assigned to a region is classified as a regional boundary node if it is connected to at least one pipe crossing between regions. The remaining mapped demand nodes are classified as regional interior nodes. When the samples were grouped by the true leak location, the Top-1 hit rates for regional boundary and interior nodes in L-town were 64.38% and 89.27%, respectively, with corresponding mean distances of 256.7 m and 193.0 m. The Top-1 hit rates for the two groups in Modena were 99.08% and 99.25%, respectively. Detailed statistics are reported in Table S17. The controlled online regional-localization scenarios used regional center nodes as leak nodes, whereas the offline group-specific results reflect localization performance at different locations within regions.
Hanoi and FOWM use node-level localization with 31 and 44 candidate node classes, respectively, and both networks use pressure inputs from all demand nodes. Their online Top-1 hit rates are 54.50% and 48.52%, respectively, and their Top-3 hit rates are 83.01% and 70.63%. Jun et al. [11] noted that network structure and leak location affect the spatial distribution of pressure responses and that weak or nearly uniform responses make leak locations more difficult to distinguish. Jun and Jung [29] also discussed the difficulty of discriminating weak leak responses in Hanoi and FOWM. In the offline evaluation at the selected localization windows, the mean pipe-length-weighted shortest-path distances from the true node to the predicted node were 540.6 m for Hanoi and 692.5 m for FOWM. The distance distributions and numbers of classes with a Top-1 hit rate below 50% are reported in Supplementary Tables S14 and S16, respectively. Figure 6 shows the network layouts, localization classes, and examples of Top-3 outputs for both localization levels. Each panel marks the true leak node and lists the identifiers of the three highest-probability classes in descending order, together with their corresponding model output probabilities. For regional localization, colored candidate nodes indicate membership in the corresponding predicted region.
Figure 6. Top-3 localization outputs for (a) L-town and (b) Modena at the regional level, and (c) Hanoi and (d) FOWM at the node level. Percentages indicate model output probabilities.

3.3. L-Town BattLeDIM Online Replay

The one-year replay used a hydraulic model to generate a continuous L-town pressure series according to the BattLeDIM event settings described in Section 2.4. The six leak locations were set according to the pipe locations of the corresponding events, and all differed from the center nodes of their respective regions. The trained detection and localization models were used, with their weights held fixed throughout the replay. The six events comprised four gradual leaks (RL1, RL2, RL4, and RL5) and two abrupt leaks (RL3 and RL6). Scenario parameters and replay results are reported in Table 4.
Temporal coverage is denoted by ηcov. This metric represents the proportion of the leak period detected by the system and is defined as
η cov = N det N total
The temporal coverage in Table 4 and the alarm periods shown in Figure 7 are based on the alarm sequence obtained after three consecutive confirmations. Only confirmed-alarm intervals containing at least three consecutive time steps are retained, with each time step lasting 5 min. Ndet is the number of time steps in these retained intervals that overlap with the true leak period. Ntotal is the total number of time steps in the true leak period. Annual false-alarm statistics and Tables S8 and S9 use the complete confirmed-alarm sequence.
Figure 7. Mean pressure response, ΔP, across the 782 demand nodes during the one-year L-town BattLeDIM replay. Panels (a–g) show successive time segments. The insets in panels (d,g) show RL3 and RL6, respectively. The horizontal axis counts 5-min time steps since the year began. The suffix k denotes 1000 time steps. The blue curve shows the mean pressure response. Green shading marks the true leak period. Pink shading marks confirmed-alarm periods that meet the condition specified in Section 3.3. Overlap between pink and green indicates detection during an actual leak. Pink shading outside the green period indicates alarms during leak-free periods. Red circles mark peak leak-rate times.
Figure 7 shows the pressure response averaged across the 782 demand nodes during the one-year L-town BattLeDIM replay. The true leak periods, system detections, and peak leak-rate times for the six reconstructed leakage scenarios are also shown.
All six scenarios produced confirmed alarms, yielding an alarm confirmation rate of 100%. The alarm delays were both 10 min for the abrupt leaks RL3 and RL6, whereas the gradual leaks had alarm delays of 35–170 min. RL5 had the longest delay, at 170 min. Temporal coverage was 95.61–98.97% across the scenarios. The first formal localization outputs for the six scenarios yielded a Top-1 hit rate of 83.33% and a Top-3 hit rate of 100%. The first formal localization output for RL3 predicted Region 12, while the true region, Region 13, was included in the Top-3 output. Effective leak-free observation time in the one-year L-town replay was 269.8056 d. In the complete confirmed-alarm sequence, 63 alarm intervals did not overlap with any true leak interval, giving a false-alarm frequency of 0.2335 events/d. Cumulative false-alarm duration during leak-free periods was 16.4167 h, including false-alarm intervals and alarm periods continuing after leak cessation. The methods for defining alarm intervals and calculating false-alarm duration are provided in the Supplementary Materials. With the same full-year pressure inputs, detection model, 1 h detection window, and probability threshold of 0.50, both one and two confirmations detected all six events, with alarm confirmation rates of 100%. Their median alarm delays were 30 and 35 min, respectively. The numbers of false-alarm intervals were 263 and 110, with corresponding false-alarm frequencies of 0.9748 and 0.4077 events/d. The median alarm delay with three consecutive confirmations was 40 min. Annual alarm statistics and event-specific alarm delays for different numbers of confirmations are reported in Tables S8 and S9 of the Supplementary Materials, respectively.
The online evaluations of the four networks in this study used ideally calibrated hydraulic models and pressure inputs from all demand nodes, while the one-year replay included six hydraulically reconstructed BattLeDIM events. In our previous study, Zhang et al. [12] evaluated PCLA binary detection using the 33 pressure-sensor locations in L-town and conducted a one-year simulated detection evaluation. Jun et al. [11] and Jun and Jung [29] used calibrated hydraulic models to generate leakage samples covering different leak locations and operating conditions. Field application requires synchronized demand, pressure, and operating records, together with calibration to ensure that the hydraulic model represents the actual system state. Demand information, measurement noise, and the leak-free reference are also important application conditions for pressure-response-based localization [13]. Future work will introduce differences in demand and roughness parameters between the reference model and the hydraulic model generating simulated observations to examine the effects of calibration error on detection and localization.

4. Conclusions

This study developed an online cascaded system for leak detection and localization based on pressure responses. Consecutive alarm confirmation, window configuration, and localization-call control were integrated into a single rolling-monitoring workflow.
Controlled online evaluations across four networks showed that consecutive confirmation reduced both the window-level FPR and the scenario-level false-alarm proportion. Alarm confirmation rates exceeded 92% in all four networks. The localization model was called only when the confirmation condition was met and a complete localization window was available. Localization-model calls included in the evaluation decreased by 41.88–62.33% relative to the all-window reference count.
In the replay of six reconstructed L-town BattLeDIM scenarios, all scenarios produced confirmed alarms. The first formal localization output included the true region in its Top-3 for every scenario. The controlled evaluations and reconstructed-scenario replay together show that the system can provide confirmed alarms and candidate locations during continuous pressure monitoring. These outputs can support targeted field investigations of unreported leaks.
The online evaluation also showed higher window-level FPR values and lower node-level localization hit rates in transmission-oriented networks. False-alarm control and node-level localization, therefore, remain priorities for improvement.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/app162311852/s1. Supplementary Methods include data splitting and training settings, offline screening criteria for detection and localization windows, construction of leak regions in Modena [30], and leak-area conversion and reference leak-to-demand ratios based on the M36 reference flow [23] and system base demands reported by Zhang et al. [12]. Figure S1. Selection of the number of leak regions in Modena. (a) Silhouette coefficients for different numbers of regions; (b) Inertia (within-cluster sum of squares) for different numbers of regions. Figure S2. The 56 leak regions in Modena. Red stars indicate the center node of each region. Red squares denote reservoirs. Table S1. Parameters for leak-area conversion in the four evaluation networks. Table S2. Proportion of correctly detected and localized scenarios and 95% confidence intervals in the supplementary simulations. Table S3. Distribution of delays to the first formal localization output in the supplementary simulations. Table S4. Offline detection results at different probability thresholds in L-town. Table S5. Offline detection results at different probability thresholds in Modena. Table S6. Offline detection results at different probability thresholds in Hanoi. Table S7. Offline detection results at different probability thresholds in FOWM. Table S8. Annual alarm statistics for different numbers of consecutive confirmations in L-town. Table S9. Alarm delays for individual leak events with different numbers of consecutive confirmations in L-town. Table S10. Window-screening sensitivity results. Table S11. Mean processing time per stage operation in the supplementary simulations. Table S12. Localization-call counts and cumulative localization processing time. Table S13. Number of model parameters, CPU forward-pass inference time, and peak process working set. Table S14. Offline localization distance statistics. Table S15. Total pipe length within the Top-3 candidate regions in L-town. Table S16. Node-level offline localization statistics. Table S17. Offline localization results for regional boundary and interior nodes. Table S18. Detection-window counts, localization calls, and cumulative processing time for leakage and no-leak scenarios.

Author Contributions

Conceptualization, Z.Z.; methodology, Z.Z. and Z.L.; validation, Z.Z.; formal analysis, W.L.; investigation, Z.L.; resources, Z.L.; data curation, Z.Z.; Writing—original draft preparation, Z.Z.; writing—review and editing, Z.L.; visualization, Z.Z. and W.L.; supervision, Z.L.; project administration, Z.L.; funding acquisition, Z.L. All authors have read and agreed to the published version of the manuscript.

Funding

The authors acknowledge the support of the Shandong Province Science and Technology Small and Medium-sized Enterprise Innovation Capability Enhancement Project (Grant No. 2024TSGC0559). The support of the Weifang City Science and Technology Small and Medium-sized Enterprise Innovation Capability Enhancement Project (Grant No. 2024TS1044) is also acknowledged.

Data Availability Statement

The original contributions presented in this study are included in the article/Supplementary Material. Further inquiries can be directed to the corresponding author.

Acknowledgments

The figures were assembled and edited by the authors using Microsoft Visio (version 16.0; Microsoft Corporation, Redmond, WA, USA; https://www.microsoft.com/en-us/microsoft-365/visio/flowchart-software, accessed on 28 November 2026). AI tools were used in a limited capacity during manuscript preparation. Specifically, ChatGPT (client version 26.1120.50957, powered by Codex & OWL; OpenAI, San Francisco, CA, USA) was used for Chinese-to-English translation, language polishing, and grammar checking to improve the clarity and readability of the English text. ChatGPT was not used to generate research ideas, analyze data, interpret results, or create the core technical content of the manuscript. The research methodology, experimental design, data collection, analysis, conclusions, and scientific contributions are the original work of the authors. The authors take full responsibility for the manuscript content. All AI-assisted text has been reviewed and verified by the authors.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Kanakoudis, V.; Tsitsifli, S.; Cerk, M.; Banovec, P.; Samaras, P.; Zouboulis, A.I. Basic principles of a DSS tool developed to prioritize NRW reduction measures in water pipe networks. Water Qual. Expo. Health 2015, 7, 39–51. [Google Scholar] [CrossRef] [Scilit]
  2. Liemberger, R.; Wyatt, A. Quantifying the global non-revenue water problem. Water Supply 2019, 19, 831–837. [Google Scholar] [CrossRef] [Scilit]
  3. Islam, M.R.; Azam, S.; Shanmugam, B.; Mathur, D. A review on current technologies and future direction of water leakage detection in water distribution network. IEEE Access 2022, 10, 107177–107201. [Google Scholar] [CrossRef] [Scilit]
  4. Wan, X.; Kuhanestani, P.K.; Farmani, R.; Keedwell, E. Literature review of data analytics for leak detection in water distribution networks: A focus on pressure and flow smart sensors. J. Water Resour. Plan. Manag. 2022, 148, 03122002. [Google Scholar] [CrossRef] [Scilit]
  5. Romero-Ben, L.; Alves, D.; Blesa, J.; Cembrano, G.; Puig, V.; Duviella, E. Leak detection and localization in water distribution networks: Review and perspective. Annu. Rev. Control 2023, 55, 392–419. [Google Scholar] [CrossRef] [Scilit]
  6. Xu, X.; Karney, B. An overview of transient fault detection techniques. In Modeling and Monitoring of Pipelines and Networks; Verde, C., Torres, L., Eds.; Springer: Cham, Switzerland, 2017; pp. 13–37. [Google Scholar] [CrossRef] [Scilit]
  7. Brunone, B.; Maietta, F.; Capponi, C.; Keramat, A.; Meniconi, S. A review of physical experiments for leak detection in water pipes through transient tests for addressing future research. J. Hydraul. Res. 2022, 60, 894–906. [Google Scholar] [CrossRef] [Scilit]
  8. Ulhaq, A.; Khan, A.; Robinson, R. Evaluating Faster-RCNN and YOLOv3 for target detection in multi-sensor data. In Statistics for Data Science and Policy Analysis; Springer: Singapore, 2020; pp. 185–193. [Google Scholar] [CrossRef] [Scilit]
  9. Siddique, M.F.; Wisal, M.; Umar, M.; Ali, S.; Janjua, M.M.; Khalid, H.; Haneef, Z.; Akhtar, N. A physics-guided statistical framework for bearing fault diagnosis under unit variability and rotational speed uncertainty. Machines 2026, 14, 1140. [Google Scholar] [CrossRef] [Scilit]
  10. Jun, S.; Lansey, K.E. Convolutional neural network for burst detection in smart water distribution systems. Water Resour. Manag. 2023, 37, 3729–3743. [Google Scholar] [CrossRef] [Scilit]
  11. Jun, S.; Jung, D.; Lansey, K. Three-dimensional convolutional neural network for leak detection and localization in smart water distribution systems. Water Res. X 2024, 25, 100264. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Zhang, Z.; Liu, Z.; Li, Y.; Li, W.; Cai, H. Small-scale leakage detection in water distribution networks based on parallel CNN–LSTM and cross-modal attention mechanism. J. Water Resour. Plan. Manag. 2026, 152, 04026056. [Google Scholar] [CrossRef] [Scilit]
  13. La Cognata, R.; Piazza, S.; Freni, G. Bridging the gap between model assumptions and realities in leak localization for water networks. Water 2025, 17, 3502. [Google Scholar] [CrossRef] [Scilit]
  14. Mohammed, E.G.; Zeleke, E.B.; Abebe, S.L. Water leakage detection and localization using hydraulic modeling and classification. J. Hydroinform. 2021, 23, 782–794. [Google Scholar] [CrossRef] [Scilit]
  15. Soldevila, A.; Boracchi, G.; Roveri, M.; Tornil-Sin, S.; Puig, V. Leak detection and localization in water distribution networks by combining expert knowledge and data-driven models. Neural Comput. Appl. 2022, 34, 4759–4779. [Google Scholar] [CrossRef] [Scilit]
  16. Daniel, I.; Pesantez, J.; Letzgus, S.; Khaksar Fasaee, M.A.; Alghamdi, F.; Berglund, E.; Mahinthakumar, G.; Cominola, A. A sequential pressure-based algorithm for data-driven leakage identification and model-based localization in water distribution networks. J. Water Resour. Plan. Manag. 2022, 148, 04022025. [Google Scholar] [CrossRef] [Scilit]
  17. Tyagi, V.; Pandey, P.; Jain, S.; Ramachandran, P. A two-stage model for data-driven leakage detection and localization in water distribution networks. Water 2023, 15, 2710. [Google Scholar] [CrossRef] [Scilit]
  18. Min, K.W.; Kim, T.; Lee, S.; Choi, Y.H.; Kim, J.H. Detecting and localizing leakages in water distribution systems using a two-phase model. J. Water Resour. Plan. Manag. 2022, 148, 04022051. [Google Scholar] [CrossRef] [Scilit]
  19. Adraoui, M.; Azmi, R.; Chenal, J.; Diop, E.B.; Ebnou Abdem, S.A.; Serbouti, I.; Hlal, M.; Bounabi, M. A two-phase approach for leak detection and localization in water distribution systems using wavelet decomposition and machine learning. Comput. Ind. Eng. 2024, 197, 110534. [Google Scholar] [CrossRef] [Scilit]
  20. Capelo, M.; Brentan, B.; Monteiro, L.; Covas, D. Near-real time burst location and sizing in water distribution systems using artificial neural networks. Water 2021, 13, 1841. [Google Scholar] [CrossRef] [Scilit]
  21. Travaš, V.; Gal, E.; Lučin, I.; Žic, E. Digital twin for a real-time leakage detection and localization in pressurized piping systems. J. Hydroinform. 2025, 27, 755–770. [Google Scholar] [CrossRef] [Scilit]
  22. Liu, H.; Jiang, J.; Zhang, X.; Ding, Y.; Yang, L.; Yang, S.-H. Leak detection and localization in water distribution networks via online change-point detection and leak sensitivity modeling. In Proceedings of the 2024 IEEE International Conference on Systems, Man, and Cybernetics (SMC), Kuching, Malaysia, 6–10 October 2024; IEEE: New York, NY, USA, 2024; pp. 2975–2980. [Google Scholar] [CrossRef] [Scilit]
  23. Kunkel, G.A., Jr. Water Audits and Loss Control Programs, 4th ed.; AWWA Manual M36; American Water Works Association: Denver, CO, USA, 2016; ISBN 978-1-62576-100-2 (print); eISBN 978-1-61300-339-8 (electronic). [Google Scholar] [CrossRef] [Scilit]
  24. Vrachimis, S.G.; Eliades, D.G.; Taormina, R.; Kapelan, Z.; Ostfeld, A.; Liu, S.; Kyriakou, M.; Pavlou, P.; Qiu, M.; Polycarpou, M.M. Battle of the leakage detection and isolation methods. J. Water Resour. Plan. Manag. 2022, 148, 04022068. [Google Scholar] [CrossRef] [Scilit]
  25. Ormsbee, L.; Hoagland, S.; Hernandez, E.; Hall, A.; Ostfeld, A. Hydraulic model database for applied water distribution systems research. J. Water Resour. Plan. Manag. 2022, 148, 04022037. [Google Scholar] [CrossRef] [Scilit]
  26. Rossman, L.A.; Woo, H.; Tryby, M.; Shang, F.; Janke, R.; Haxton, T. EPANET 2.2 User Manual; EPA/600/R-20/133; U.S. Environmental Protection Agency: Washington, DC, USA, 2020. [Google Scholar]
  27. Klise, K.; Hart, D.; Bynum, M.; Hogge, J.; Haxton, T.; Murray, R.; Burkhardt, J. Water Network Tool for Resilience (WNTR) User Manual, Version 1.0; EPA/600/B-23/098; U.S. Environmental Protection Agency: Washington, DC, USA, 2023. [Google Scholar]
  28. Rajabi, M.M.; Komeilian, P.; Wan, X.; Farmani, R. Leak detection and localization in water distribution networks using conditional deep convolutional generative adversarial networks. Water Res. 2023, 238, 120012. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Jun, S.; Jung, D. Exploration of deep learning leak detection model across multiple smart water distribution systems: Detectable leak sizes with AMI meters. Water Res. X 2025, 29, 100332. [Google Scholar] [CrossRef] [Scilit]
  30. Zhang, Q.; Wu, Z.Y.; Zhao, M.; Qi, J.; Huang, Y.; Zhao, H. Leakage zone identification in large-scale water distribution systems using multiclass support vector machines. J. Water Resour. Plan. Manag. 2016, 142, 04016042. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.