Skip to Content
Applied SciencesApplied Sciences
  • Article
  • Open Access

27 November 2026

28 Pages

Greenhouse Gas Accounting and Mitigation Pathways for an A2O Wastewater Treatment Plant: Insights from Multi-Scale Field Monitoring

,
,
,
,
and
1
Key Laboratory of Intelligent Perception and Ecological Restoration of River and Lake Health, Ministry of Education, Hubei Key Laboratory of Environmental Geotechnology and River-Lake Ecological Restoration, College of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2
Gezhouba Group Ecological Environmental Protection Co., Ltd., Wuhan 430000, China
*
Author to whom correspondence should be addressed.

Abstract

Greenhouse gas (GHG) accounting for wastewater treatment plants (WWTPs) relies heavily on default emission factors of the Intergovernmental Panel on Climate Change (IPCC)and lacks support from localized measurements. This study investigated an Anaerobic–Anoxic–Oxic (A2O) municipal WWTP in Danjiangkou City (design capacity of 6.5 × 104 m3/d), located in the core water source area of the middle route of the South-to-North Water Diversion Project. Seventeen months of operational data (January 2024–May 2025) and 30 days of continuous online flux monitoring (May–June 2025) were integrated to construct a gate-to-gate GHG inventory. The results showed that the plant emitted an average of 562.44 t CO2-eq per month, corresponding to an emission intensity of 0.31 kg CO2-eq/m3, below the nationwide mean reported for Chinese WWTPs, while energy-related indirect emissions accounted for 45.54% of the total. The measured CH4 and N2O emission factors were only 44.4% and 4.3% of the IPCC defaults, respectively, with the anaerobic tank identified as the primary CH4-release unit and the aerobic tank as the largest N2O-release unit. Monte Carlo analysis indicated that the selection of emission factors was the leading source of accounting uncertainty, contributing 68% of the total. Across the observational before–after comparison, the share of energy-related emissions was 49.64% before and 39.67% after PV commissioning; the modelled combination of photovoltaic generation and refined aeration control indicates environmental and economic potential rather than a demonstrated causal reduction. Demonstrating both environmental and economic sustainability. These findings provide a basis for precise carbon accounting and low-carbon operation of WWTPs in water source protection zones. On this basis, localized emission factor databases are recommended for water source areas, in which default factors are known to overestimate emissions substantially.

1. Introduction

Global climate change has emerged as one of the most severe environmental challenges confronting human society. The rising atmospheric concentrations of greenhouse gases (GHGs)—primarily carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O)—driven by anthropogenic activities constitute the principal driver of this trend. To curb the deterioration of the global climate, the Paris Agreement established a global climate governance framework; in 2020, China further announced its “dual carbon” goals, namely carbon peaking and carbon neutrality, calling for the establishment of greenhouse gas (GHG) emission accounting and statistical systems covering key sectors [1,2,3]. Against this backdrop, the wastewater treatment sector, as a key area for precise carbon accounting and low-carbon transition, urgently requires a scientifically rigorous methodology for GHG quantification.
The wastewater treatment industry constitutes a major anthropogenic intervention node in the global carbon cycle, contributing approximately 1–2% of global GHG emissions [4,5,6,7,8,9]. Its carbon emissions are generally classified into two categories: direct emissions from biochemical reactions and indirect emissions associated with energy consumption and chemical use [10]. With the largest wastewater treatment capacity in the world, China achieved a treatment rate of 98.93% in 2024, underscoring the growing significance of the sector’s carbon emissions [11,12,13,14,15]. However, existing studies have largely focused on model-based accounting, with continuous in situ measurements targeting specific treatment units remaining scarce [16,17,18]. In addition, the direct adoption of IPCC default emission factors may introduce systematic bias owing to differences in water quality and process configurations [19,20].
Three gaps persist in the existing research: (1) full-scale field measurements of wastewater treatment plants (WWTPs) situated in national water source conservation zones—exemplified by the core water source area of the Middle Route of the South-to-North Water Diversion Project—remain scarce; such plants typically treat influent with low organic loading, are subject to the stringent Class IA discharge standard, and experience frequent hydraulic shocks during the rainy season, rendering the applicability of IPCC default parameters to these facilities uncertain; (2) measured emission factors for the A2O process in China exhibit pronounced scatter, with some values exceeding and others falling below the IPCC defaults, yet the mechanisms driving this divergence are poorly understood; and (3) research on photovoltaic (PV)-integrated WWTPs has largely been confined to simulation-based estimation, and empirical case studies that quantify emission reductions from long-term operational data of full-scale plants remain limited. To this end, a municipal wastewater treatment plant (WWTP) in Danjiangkou City, China, which employs the A2O process (design capacity: 6.5 × 104 m3/d) and is located in the core water source area of the Middle Route of the South-to-North Water Diversion Project within a national first-grade water source protection zone, was selected as the study site.
Accordingly, the three gaps identified above were translated into three testable objectives, each with an explicit evaluation criterion: (O1) to quantify the monthly operational GHG inventory and emission structure of a full-scale A2O plant in a water source protection zone using the IPCC inventory method, tested against the provincial mean emission intensity (Section 3.2); (O2) to determine site-specific CH4 and N2O emission factors for individual treatment units by in situ flux monitoring and to test their deviation from IPCC defaults, with the dominant uncertainty source identified by Monte Carlo simulation (Section 3.3, Section 3.4 and Section 3.5); and (O3) to compare the share of energy-related emissions and purchased grid electricity before and after PV commissioning, and to assess whether the observed difference is consistent with on-site PV generation (Section 3.2.3). Because the pre-PV period (January–October 2024) and the post-PV period (November 2024–May 2025) differ in seasonal composition and no concurrent control plant was available, O3 is an observational before–after comparison; the associated differences are reported as correlations, and no causal effect is claimed (Section 4.3.1). The monthly inventory was constructed entirely using IPCC default emission factors, whereas the measured emission factors were derived from a short-term monitoring campaign conducted in May–June 2025; the temporal boundaries and intended uses of the two datasets are defined in Section 2.4.
This study is complementary to the national-scale work of Song et al. [20] and Li et al. [21]: whereas those studies provided broad national-scale inventories, the present work delivers site-specific emission factors and actionable mitigation pathways for a representative plant within a single water source area. The findings contribute to the United Nations Sustainable Development Goals (SDGs) 6, 7, 12, and 13. The remainder of this paper is organized as follows. Section 2 describes the study site, data, and methods. Section 3 reports the results. Section 4 discusses the mitigation pathways and outlines the study limitations. Section 5 presents the conclusions.

2. Materials and Methods

2.1. Plant Overview and Process Description

The study plant is a WWTP located in Danjiangkou City, Hubei Province, China. It is an open-air, above-ground facility with a maximum design capacity of 6.5 × 104 m3/d, and its effluent must comply with the Class IA discharge limits of the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plants (GB 18918—2002) [22]. The treatment train is schematically shown in Figure 1, and the main process parameters are summarized in Table 1. The plant receives predominantly municipal domestic wastewater; infiltration and inflow from the sewer network are pronounced during the rainy season, and the influent substrate is generally low. Excess sludge is thickened, dewatered with belt filter presses, and thermally dried prior to off-site transport and disposal.
Figure 1. Schematic of the A2O process flow and the distribution of sampling points (S1–S3 denote static floating chamber sites). Note: The labels indicating emission units are based on the monitoring results of this study.
Table 1. Main process parameters of the wastewater treatment plant.

2.2. Data Sources

2.2.1. Long-Term Operation Data

This study integrated the long-term operational data of the WWTP from January 2024 to May 2025 (a total of 17 months), including the following. (1) Influent and effluent water quality. From January to March 2024, the outflow volume was abnormally higher than the inflow volume; following verification with the operator, it was confirmed that the outflow meter had malfunctioned, expressed as monthly mean concentrations of chemical oxygen demand (COD), total nitrogen (TN), ammonia nitrogen (NH3-N) and total phosphorus (TP). (2) Monthly cumulative influent volume (m3/month). (3) Monthly electricity consumption (kWh/month). (4) Chemical dosages, namely polyferric sulfate (kg/month), sodium acetate (kg/month), polyaluminum chloride (PAC) (kg/month), and sodium hypochlorite (kg/month). Among these, the period from January to October 2024 corresponds to the pre-PV-commissioning stage, whereas the period from November 2024 to May 2025 corresponds to the post-PV-commissioning stage.

2.2.2. Continuous GHG Monitoring Data

From May to June 2025 (a continuous 30-day period), GHG online monitoring was conducted on Line 1 of the biological treatment stage at the WWTP. The sampling sites covered the three core units—the anaerobic, anoxic, and aerobic tanks (Figure 2). The monitoring apparatus was a high-precision GHG analyzer (model GW-2082) designed and developed by Wuhan Ganwei Technology Co., Ltd in China., which simultaneously measures the concentrations of CO2, N2O, CH4, and H2O based on cavity ring-down spectroscopy (CRDS) technology, with a measurement sensitivity at the parts-per-billion (ppb) level. The static floating chamber method was adopted for sampling: three replicate sampling points were established at each site, each sampling event lasted no less than 30 min, and measurements were taken synchronously and continuously for 24 h per day. Water quality parameters collected in parallel included TN, COD, NH3-N, DO, pH, and water temperature, whereas operational parameters included sludge retention time (SRT), aeration intensity, hydraulic retention time (HRT), and internal recirculation ratio. To ensure data quality, the analyzer was periodically calibrated for zero and span using standard gases during the campaign, and consistency checks were performed on parallel samples at each sampling site.
Figure 2. Schematic diagram of sampling points in the wastewater treatment plant.
The selection of the monitoring period (May–June 2025) was based on the following considerations. (1) Hydraulic load: the monthly average influent volume from January to May 2025 (1,847,466 m3) was essentially consistent with the annual monthly average for 2024 (1,838,991 m3); the water volume during the monitoring period fell within the normal annual fluctuation range, avoiding both the extreme high-flow conditions caused by the exceptional rainstorm in July 2024 and the low-flow conditions of the dry season. (2) Operating conditions: the biological system operated stably during the monitoring period, with key parameters such as SRT (15–18 d) and the internal recirculation ratio within their design operating ranges, and the precise DO control strategy remained in normal operation. (3) Water quality: May–June falls in the early rainy season locally, and the influent dilution level was comparable to that during the main rainfall period of the year (April–July), so the fluctuation characteristics of the influent quality were typical. Accordingly, the campaign is treated as a within-range case rather than a representative one: Table A1 compares May 2025 with the full 17-month record for influent COD, TN, NH3-N, TP, TN load, flow, power and chemical dosages, while temperature, DO, rainfall and aeration lack 17-month records. Seasonal extrapolation of the 30-day fluxes is therefore a major uncertainty (Section 2.3.5 and Section 4.5).

2.3. Greenhouse Gas (GHG) Emission Accounting Methodology

2.3.1. Accounting Boundary and Emission Source Classification

The accounting boundary was defined with reference to the 2019 Refinement to the IPCC Guidelines for National Greenhouse Gas Inventories and the Guideline for Formulating Provincial CO2 Peaking Action Plans [23,24], and comprised two parts: direct and indirect emissions. Direct emissions refer to GHG generated directly during the treatment process, including CH4 and N2O emissions from COD removal, TN removal, and sludge treatment. Indirect emissions refer to indirect GHG emissions associated with purchased energy or resources, including CO2 emissions from electricity consumption and chemical dosing. Given that CO2 derived from biochemical oxygen demand (BOD) during wastewater or sludge treatment is regarded as part of the natural carbon cycle [25], and most existing literature routinely excludes fossil-derived CO2 from the conventional assessment scope [26,27,28], this study excluded fossil-derived CO2 emissions from the accounting. This gate-to-gate boundary excludes construction, equipment manufacturing, and off-site sludge disposal.

2.3.2. Direct Emission Accounting

Greenhouse Gas emissions from COD removal
E1 = [(CODin — CODout) × Q × 10−3(g → kg) × EFCH4 — RCH4] × GWPCH4 × 10−3(kg → t)
where CODin is the influent COD concentration (mg/L); CODout is the effluent COD concentration (mg/L); Q is the monthly cumulative influent volume (m3); 10−3(g → kg) converts grams to kilograms (mg/L × m3 yields grams); EFCH4 is the CH4 emission factor, taken as 0.0081 kg CH4/kg COD removed [29]; RCH4 is the mass of CH4 recovered and utilised for energy (kg CH4/month), set to 0 for this plant because no anaerobic digestion or methane-recovery unit is installed (MCFAD = 0 in Equation (3)); it is subtracted before applying GWPCH4 so that both terms are in kg CH4; GWPCH4 is the global warming potential of CH4 over a 100-year time horizon, taken as 27.9 (IPCC Sixth Assessment Report (AR6), 2021) [30]. The second 10−3(kg → t) converts kg CO2-eq to t CO2-eq. Equation (1) yields the CH4-related emission in t CO2-eq/month.
Greenhouse Gas emissions from Total Nitrogen (TN) removal
E2 = (TNin — TNout) × Q × 10−3(g → kg) × EFN2O × GWPN2O × CN2O/N × 10−3(kg → t)
where TNin and TNout are the influent and effluent total nitrogen concentrations (mg/L as N), respectively; Q is the cumulative monthly influent flow (m3); 10−3(g → kg) is the unit conversion factor from grams to kilograms for mg/L·m3; EFN2O is the IPCC 2019 [24] Refinement Tier 1 global default emission factor, taken as 0.016 kg N2O-N/kg TN (expressed as N2O-N, i.e., 0.016 kg N2O-N is produced per kg of nitrogen removed), which is consistent with domestic measurement-based studies on wastewater N2O emissions; CN2O/N is the molecular-weight conversion coefficient between N2O and N2O-N (44/28); and GWPN2O is the 100-year global warming potential of N2O, taken as 273 (IPCC AR6, 2021) [30]. 10−3(kg → t) is the kilogram-to-tonne conversion. Equation (2) yields the N2O-related emission in t CO2-eq/month.
Total Greenhouse Gas Emissions from Sludge Treatment
E3 = SR × βS × MCFAD × F × CCH4/C × GWPCH4
where SR is the amount of sludge dry solids removed (t/month); βS is the organic matter content in the sludge dry solids, taken as 0.5 t/t; MCFAD is the anaerobic methane correction factor, taken as 0; F is the fraction of degradable organic carbon that can be converted to CH4, taken as 50%; and CCH4/C is the molecular-weight ratio of CH4 to C (16/12).

2.3.3. Indirect Emission Accounting

GHG emissions from energy consumption
E4 = ADelec × EFelec × 10−3
where ADelec is the total purchased electricity consumption of the WWTP (kWh/month); EFelec is the average emission factor of the regional power grid, taken as 0.58 kg CO2/kWh (China provincial grid emission factor, per the guidelines of the Ministry of Ecology and Environment); and 10−3 is the conversion factor from kilograms to tonnes.
GHG emissions from chemical consumption
E5 = ∑ (MC∗j × EFC∗j) × 10−3
where MC∗j is the dosage of the j-th chemical agent (kg/month); EFC∗j is the emission factor of the j-th chemical agent, specifically: polymeric ferric sulfate, EF = 0.40 kg CO2/kg of pure product; sodium acetate, EF = 0.623 kg CO2/kg; polyaluminum chloride (PAC), EF = 0.54 kg CO2/kg; and sodium hypochlorite, EF = 0.92 kg CO2/kg; and 10−3 is the conversion factor from kilograms to tonnes.

2.3.4. Total Emissions and Emission Intensity Calculation

In accordance with the IPCC accounting methodology and other relevant studies [25,30], the calculation methods for total greenhouse gas (GHG) emissions are as follows:
EZ = E1 + E2 + E3 + E4 + E5
where EZ is the total accounted GHG emission of the municipal WWTP (expressed as CO2-equivalent) (t/month); E1 is the accounted GHG emission from COD removal (t/month); E2 is the total accounted GHG emission from total nitrogen removal (t/month); E3 is the total accounted GHG emission from sludge treatment (t/month); E4 is the total accounted GHG emission from energy consumption (t/month); and E5 is the total accounted GHG emission from chemical consumption (t/month). All five terms in Equation (6) are in t CO2-eq/month and are summed directly; in Equation (7), the factor 103 converts tonnes to kilograms, so EZ/Q yields kg CO2-eq/m3.
The accounting formula for greenhouse gas (GHG) emission intensity is shown as follows:
Em = EZ × 103/Q
where Em is the accounted GHG emission intensity of the municipal WWTP (kg CO2-eq/m3); EZ is the total accounted GHG emission (t/month); and Q is the monthly cumulative influent volume (Q, m3/month), identical to Q in Equations (1) and (2).

2.3.5. Uncertainty Analysis—Monte Carlo Simulation

Uncertainty analysis was conducted using the Monte Carlo method, with 10,000 iterative sampling runs. The probability distributions of the parameters were specified as follows: (1) the emission factor parameters (EFCH4 and EFN2O) followed a triangular distribution, with the bounds informed by the IPCC-recommended ranges and domestic measured literature values; (2) the monthly average influent COD and TN concentrations followed a normal distribution, parameterized by the mean and standard deviation of the 17-month measured dataset; (3) the operating parameters, such as aeration intensity and recirculation ratio, followed a uniform distribution, with the range corresponding to the actual operating fluctuation intervals; and (4) regarding the uncertainty in monitoring-period representativeness, a prior distribution of the coefficient of variation (CV) of the annual emission factors was specified—accounting for seasonal variation in the emission factors—with CV = 30% under a triangular distribution, to quantify the representativeness risk of extrapolating the 30-day monitoring period to the full year. The distribution settings for each parameter were based on the uncertainty-analysis chapter of the IPCC 2019 Refinement [25] and domestic measured studies [31,32,33]. All parameters were sampled independently, with no correlation structure imposed. Full numerical bounds, means, standard deviations and their rationale are given in Table A2. The seasonal-representativeness term is a triangular multiplier on the emission factors with bounds of ±30% and mode 1.00 (0.70–1.30; mean 1.000, SD 0.122); the label “CV = 30%” denotes the assumed maximum seasonal deviation, not the sample CV of this triangular prior, and it enters only the uncertainty sampling, not the 17-month point estimates. Contributions to uncertainty were quantified by a group-wise conditional variance decomposition: each group of inputs was fixed at its central value in turn, the 10,000-run simulation was repeated, and the relative reduction in the variance of E_Z was reported as that group’s contribution (the same metric, applied to individual inputs, gives the single-parameter ranking).

2.4. In-Situ Flux Monitoring and Emission Factor Calculation

The temporal boundaries and intended uses of the two data systems are first defined. The IPCC monthly inventory accounting covers 17 months from January 2024 to May 2025 and adopts IPCC default emission factors exclusively (see Section 2.3). The in-situ continuous flux monitoring was conducted only in May–June 2025; the measured emission factors thereby obtained (Equations (9) and (10)) were used solely for comparison with the IPCC default values, Monte Carlo parameter calibration, and emission-reduction mechanism analysis, and were not fed back to re-estimate the 17-month monthly total emissions.

2.4.1. Sampling Method

Sampling was conducted using the static floating chamber method, with three replicate sampling points established in each of the anaerobic, anoxic, and aerobic tanks. The chambers were constructed of transparent acrylic (plexiglass), with the bottom sealed over the water surface, and gas samples were collected through a sampling port. At each site, the duration of each sampling event was no less than 30 min, and measurements were carried out as continuous, synchronous 24-h determinations per day. The monitoring period covered a total of 30 days from May to June 2025.

2.4.2. Flux Calculation

Flux = (dc/dt) ∗ (V/Vm) ∗ (1/A) ∗ (T1/T2)
where Flux is the gas flux (μmol/(m2·s)); dc/dt is the rate of change in gas concentration with time (ppm/s); V is the combined volume of the chamber, sampling tube, and optical cavity (0.007284 m3); Vm is the molar volume of an ideal gas at 273 K (22.4 × 10−3 m3/mol); A is the covered area of the chamber (0.031415 m2); and T1 is the standard temperature (273 K). In the equation, the ratio T1/T2 serves as a temperature correction factor that converts the gas volume at the actual chamber temperature (T2) to the standard state (273 K, T1); Vm is uniformly taken as the ideal-gas molar volume at 273 K, which ensures the comparability of flux results across batches measured at different temperatures.

2.4.3. Calculation of Emission Factors

EFCH4 = CH4E/CODR
EFN2O = N2OE/TNR
where EFCH4 is the measured CH4 emission factor (kg CH4/kg COD); CH4E is the CH4 emission during the accounting period (kg); CODR is the COD removal during the accounting period (kg); EFN2O is the measured N2O emission factor (kg N2O/kg TN); N2OE is the N2O emission during the accounting period (kg); and TNR is the TN removal during the accounting period (kg).

2.5. Data Analysis Methods

2.5.1. Descriptive Statistics

Descriptive statistical analysis was performed on the GHG emission fluxes, water-quality parameters, and operating parameters of each unit, comprising the mean, standard deviation, and 95% confidence interval, to characterize the basic distributional features of the parameters.

2.5.2. Correlation Analysis

Spearman’s rank correlation analysis (a non-parametric method appropriate for non-normally distributed data) was employed to assess the correlations between the N2O and CH4 emission fluxes in each unit and the operating parameters—including dissolved oxygen (DO), water temperature, COD loading, TN loading, hydraulic retention time (HRT), sludge retention time (SRT), and internal recirculation ratio—in order to identify the significant correlated factors (p < 0.05).

2.5.3. Scenario Analysis

The scenario comparison is model-based and distinct from the observational before–after comparison of operational records in Section 3.2.3. Two operating scenarios were defined for comparison: (1) the A2O baseline scenario, adopting the conventional A2O process combined with full grid-power supply; and (2) the A2O + PV scenario, in which the conventional A2O process was coupled with the plant’s distributed photovoltaic (PV) power generation system under a “self-consumption, surplus-to-grid” operation mode. By comparing the energy-related emissions and total carbon footprint between the two scenarios, the emission-reduction benefit of PV generation was quantified.

3. Results

3.1. Operational Characteristics of Wastewater Treatment Plants

3.1.1. Wastewater Flow Variation Characteristics

The monitoring data of influent and effluent water volumes of the Danjiangkou WWTP are presented in Figure 3. The total influent volume in 2024 was 22,067,890 m3, with a monthly average of 1,838,991 m3; the total influent volume from January to May 2025 was 9,237,329 m3, with a monthly average of 1,847,466 m3. Monthly influent volume ranged from 1.11 × 106 m3 (March 2024) to 2.36 × 106 m3 (December 2024), a 113% spread, and the April–July 2024 rise coincided with the local rainy season. Because the record spans only 17 months (1.4 annual cycles, with just five calendar months observed twice), these month-to-month variations are described without inferring seasonality. Meteorological records indicate that precipitation in the Danjiangkou area in 2024 was about 40% above the long-term normal. In July 2024, the urban area experienced an extreme rainstorm, with the maximum single-event precipitation reaching 337.4 mm—exceeding the historical extreme—and the abundant rainfall further corroborates the plausibility of the elevated influent during that period. In addition, the influent volume in December 2024 was markedly higher than in other months, attributable to increased discharges of domestic sewage and industrial wastewater that month. The seasonal fluctuation pattern of the plant’s influent volume is generally consistent with the widely observed influent-variation pattern of municipal WWTPs across China [34].
Figure 3. Monthly variation characteristics of influent and effluent flow in the wastewater treatment plant (January 2024–May 2025), Notes: Jan–Mar 2024 effluent volumes were estimated from the influent volume via water balance owing to an effluent flowmeter malfunction.

3.1.2. Water Quality and Pollutant Removal Efficiencies

Figure 4 presents the water-quality monitoring data. The influent COD and TN concentrations of the Danjiangkou WWTP fluctuated considerably, reaching their annual minima in July–August 2024, mainly owing to dilution of the sewer network by heavy summer precipitation [35]. In 2024, the average influent COD concentration was 148.48 mg/L, the average effluent concentration was 13.12 mg/L, and the average removal efficiency was 90.65%; the average influent TN concentration was 24.38 mg/L, the average effluent concentration was 8.68 mg/L, and the average removal efficiency was 63.75%. The average influent BOD5/TN ratio was 2.31, substantially below the 4–6 range indicative of sufficient carbon source for denitrification, revealing a pronounced carbon-source limitation in the system. The average influent BOD5/COD ratio was 0.29, further indicating a low content of readily biodegradable organic matter [36]. Following systematic process upgrading and retrofitting, the plant gradually reduced the dosage of the external carbon source sodium acetate and ceased routine dosing from 1 January 2024, with emergency dosing of only 4500 kg and 6000 kg applied in October 2024 and February 2025, respectively. From August to October 2024, the TN removal efficiency increased from 49.55% to 65.50%, demonstrating that optimized operation and management can partially mitigate the carbon-source limitation.
Figure 4. Monthly COD and TN concentrations in the inlet and outlet water of the wastewater treatment plant and the removal rates.

3.1.3. Energy and Chemical Consumption Characteristics

During the study period, the plant’s average monthly electricity consumption was approximately 437,000 kWh, and the average monthly chemical consumption (including polymeric ferric sulfate, sodium acetate, PAC, and sodium hypochlorite) was approximately 73.8 t. Energy-related emissions accounted for 45.54% of the average monthly total GHG emissions, making electricity consumption the largest single emission source. Regarding chemical dosing, polymeric ferric sulfate and PAC were mainly used for chemical phosphorus removal, sodium acetate served as the carbon source for denitrification (gradually phased down), and sodium hypochlorite was applied for effluent disinfection. Notably, the low influent COD concentration (average 148.48 mg/L, only 37–62% of the European average) substantially increased the electricity consumption per unit of pollutant removed; the baseline energy demand of units such as aeration, recirculation, and advanced treatment is difficult to reduce correspondingly, which further amplifies the carbon emission intensity of the energy-consumption stage [37].

3.2. Plant-Wide Greenhouse Gas Emission Characteristics

3.2.1. Total Emissions and Composition

As shown in Figure 5, the average monthly total GHG emission of the Danjiangkou WWTP was 562.44 t/month (95% confidence interval: 528.32–596.58 t/month), and the average monthly emission intensity was 0.31 kgCO2-eq/m3 (95% CI: 0.28–0.34 kg/m3), about 31% below the nationwide mean of 0.45 kg CO2-eq/m3 reported for 247 full-scale municipal WWTPs across China [38]. In terms of emission composition, energy-related emissions accounted for 45.54% (arithmetic mean of the 17 monthly shares) of the monthly average, COD-removal emissions about 10.75%, TN-removal emissions about 36.36%, and chemical-consumption emissions about 7.35% [39]. Figure 5 shows three consistent features. First, monthly total emissions and emission intensity do not vary in parallel: total emissions rise with influent volume during the April–July rainy season, whereas intensity declines slightly over the same period because COD and TN concentrations are diluted (Section 3.2.2). Second, the mean source structure is dominated by indirect emissions—electricity (45.54%) and chemicals (7.35%) together contribute 52.89%, exceeding the two direct terms (TN removal 36.36%; COD removal 10.75%)—so energy use is the largest single mitigation lever. Third, the energy share shifts after PV commissioning in November 2024 (49.64% → 39.67%; Section 3.2.3), reflecting both lower electricity emissions and higher non-electric emissions (absolute values in Table A3).
Figure 5. Monthly total greenhouse gas (GHG) emissions, emission intensity and proportion of each emission source in the plant.

3.2.2. Emission Temporal Variation Characteristics

Examining the monthly trend, the total GHG emissions were positively correlated with the influent water volume; during the rainy season (April–July), the surge in water volume drove an increase in total emissions. The emission intensity, by contrast, was governed by the dilution effect of influent concentration and decreased slightly in the rainy season owing to the reduced influent COD and TN concentrations. The Monte Carlo simulation results indicated that the choice of emission factors, fluctuations in influent water quality, and variations in operating parameters were the three principal factors influencing the accounting results, contributing 68%, 21%, and 11% of the output variance, respectively (group-wise variance decomposition; Section 2.3.5). Among individual parameters, the N2O emission factor exhibited the highest variance contribution (42%) under the same metric, followed by the CH4 emission factor (18%) and the fluctuation of influent TN concentration (15%).

3.2.3. Observational Before–After Comparison of Energy-Related Emissions Across PV Commissioning

This comparison is observational: the pre-PV period (January–October 2024) and the post-PV period (November 2024–May 2025) differ in seasonal composition, and no concurrent control plant was available; the differences reported below are therefore interpreted as associations rather than causal effects (Section 4.3.1). The plant commissioned a distributed photovoltaic (PV) power generation system in November 2024 (installed capacity ≈ 1200 kWp), operating under a “self-consumption, surplus-to-grid” mode, with PV panels mounted above the biological tanks, sedimentation tanks, and on the roofs of ancillary buildings. Comparing the periods before and after PV commissioning: from January to October 2024 (pre-PV), the monthly average share of energy-related emissions was 49.64%; from November 2024 to May 2025 (post-PV), this share was 39.67%, a relative difference of 20.08%, corresponding to a monthly saving of approximately 81,000 kWh in grid electricity consumption and an indirect CO2 emission reduction of about 47.0 t/month. PV output was concentrated 85% in the daytime window of 08:00–18:00, coinciding with the high-load operation period of the aeration system, yielding a load-matching degree of 79%. From the electricity-side evidence, the plant’s average monthly purchased electricity fell by approximately 81,000 kWh after PV commissioning, which corroborates the aforementioned decline in the emission share. In absolute terms, mean monthly emissions were 541.38 t CO2-eq (electricity 267.01 t) before and 592.54 t (electricity 234.04 t) after commissioning, while non-electric emissions rose from 274.37 to 358.50 t CO2-eq/month; the full component breakdown and the activity data are given in Table A3.

3.3. Comparison Between Site-Specific Emission Factors and IPCC Default Valuesn

Targeting the operational characteristics of the A2O process at the Danjiangkou WWTP, this study conducted continuous field monitoring in the biological treatment stage from May–June 2025, performing 24-h synchronous measurements of the CH4 and N2O emission fluxes from the three core units—anaerobic, anoxic, and aerobic. Compared with flux-monitoring studies of underground WWTPs [40], the subject of this study is an above-ground open-air plant, where the fluxes are more directly affected by meteorological conditions.
The measured results showed that the emission fluxes of the two greenhouse gases exhibited significant spatial differentiation across the different biochemical units (Figure 6): CH4 emissions were concentrated in the anaerobic tank, with a flux range of 1.91–3.32 g/m2·d, more than 10 times that of the anoxic tank (0.19–0.37 g/m2·d) and more than 8 times that of the aerobic tank (0.13–0.86 g/m2·d). N2O exhibited the opposite distribution pattern, with the aerobic tank being the largest emitting unit, reaching a flux range of 0.049–0.242 g/m2·d, which was 16 times that of the anoxic tank (0.0038–0.015 g/m2·d) and more than 20 times that of the anaerobic tank (0.0038–0.0082 g/m2·d).
Figure 6. CH4 and N2O emission flux ranges of each unit in the biochemical section (minimum–maximum values during the 30-day monitoring period).
It should be noted that this study adopted a multi-scale approach whereby the IPCC monthly inventory and the short-term measured factors corroborate one another: the GHG totals for the 17-month period were all calculated on the basis of IPCC default emission factors (see Section 2.3), whereas the site-specific emission factors obtained from 30 days of continuous monitoring were used only for comparison with the IPCC default values and for calibrating the parameters in the uncertainty analysis. During the monitoring period (May–June), the water temperature and influent loading were moderately high relative to the annual mean; the measured factors may therefore slightly overestimate winter emissions and underestimate the summer peak. Their seasonal applicability is discussed further in Section 4.3.1.

3.4. Spatial Distribution Characteristics of Emission Fluxes in the Biochemical Section

To further identify the key drivers of GHG emissions, this study employed Spearman’s rank correlation analysis to examine the correlations between the N2O and CH4 emission fluxes in each unit and operating parameters such as dissolved oxygen (DO), water temperature, COD loading, TN loading, hydraulic retention time (HRT), sludge retention time (SRT), and internal recirculation ratio (Table 2). The correlation analysis was based on 30 days of continuous monitoring data (n = 30); * indicates p < 0.05 and ** indicates p < 0.01 (Table 2).
Table 2. Spearman correlation analysis between GHG emission fluxes and operating parameters.
Table 2 shows a clear separation of drivers between the two gases. CH4 fluxes are associated mainly with organic loading and temperature: COD loading gives the strongest coefficients in all three tanks (r = 0.58**, 0.42**, 0.36*), water temperature is significant in the anaerobic and anoxic tanks (0.45**, 0.31*), and DO is negatively associated with anaerobic CH4 (−0.32*) but positively with aerobic CH4 (0.41**). In contrast, N2O fluxes respond primarily to operational settings: the aerobic-tank flux increases with DO (0.53**) and TN loading (0.48**) and decreases with SRT (−0.42**) and IRR (−0.45**), while the anoxic-tank flux follows TN loading (0.45**) and IRR (−0.36*). HRT, SRT and IRR are largely non-significant for CH4 (|r| ≤ 0.27, no asterisk), indicating that CH4 is governed mainly by substrate and temperature with DO as a sign-dependent secondary control, whereas N2O is more sensitive to aeration and recirculation. All coefficients are moderate (|r| ≤ 0.58) and, with n = 30, denote association rather than causation. A mechanistic interpretation is given in Section 4.2.

3.5. Comparison Between Site-Specific Emission Factors and IPCC Default Values

3.5.1. Field-Measured Emission Factor Results

Based on the pollutant removal data for the 17-month period and the continuous flux monitoring results, the measured emission factors for the biological treatment stage were determined as follows: the CH4 emission factor ranged from 0.00203 to 0.00558 kg CH4/kg COD, with a mean of 0.00333 kg CH4/kg COD; the N2O emission factor ranged from 0.000197 to 0.00118 kg N2O-N/kg TN, with a mean of 0.000687 kg N2O-N/kg TN.

3.5.2. Comparison with IPCC Default Values

Comparison of the measured values with the default values from the IPCC 2006 Guidelines for National Greenhouse Gas Inventories (2019 Refinement) showed that the mean measured CH4 emission factor was only 44.4% of the IPCC default (0.0075 kg CH4/kg COD), and the mean measured N2O emission factor was only 4.3% of the IPCC default (0.016 kg N2O-N/kg TN). All measured values fell within the IPCC parameter ranges (CH4: 0.00075–0.0225; N2O: 0.00016–0.045), indicating that the measured results are statistically plausible. The comparison is presented in Figure 7. The pattern in Figure 7 is therefore a systematic downward shift rather than a methodological discrepancy: both measured factors lie within the IPCC ranges yet near their lower bounds (44.4% and 4.3% of the defaults).
Figure 7. Comparison of IPCC default values and field-measured emission factors from this study (error bars represent the minimum–maximum ranges of field measurements).

3.5.3. Comparison with Domestic Comparable Studies

A further comparison with comparable domestic studies (Table 3) shows that the emission factors determined in this study lie at the lower end of the range of domestically measured data: Li et al. [31] summarized a mean N2O emission factor of 0.0032 kg N2O-N/kg TN across 27 A2O WWTPs nationwide, which is 4.66 times the value measured in this study; Wang et al. [32] reported a mean of 0.0027 kg N2O-N/kg TN for 11 A2O WWTPs in central China, 3.93 times the present value; and Zhang et al. [33] obtained a mean of 0.0019 kg N2O-N/kg TN for A2O plants treating low-carbon influent, 2.76 times the value measured here. Song et al. [20] pointed out that the IPCC emission factor database mixes observational data from different scales and processes and does not account for the positive effect of process optimization on emission reduction, resulting in a systematic overestimation of emissions for conventional biological nitrogen removal processes.
Table 3. Comparison of emission factors among this study, domestic comparable studies and IPCC default values.

4. Discussions

4.1. Attribution Analysis of Low Emission Factors and Interpretation of Differences from Domestic Literature

The low measured values in this study can be attributed to three main factors. (1) The plant employs a precise DO control strategy, maintaining DO in the aerobic stage at 2.0–3.0 mg/L, which safeguards nitrification efficiency while suppressing excessive N2O formation; (2) although the influent carbon-to-nitrogen ratio was relatively low (BOD5/TN = 2.31), optimization of the internal recirculation ratio (IRR) achieved efficient nitrification–denitrification synergy and reduced the accumulation of intermediates; and (3) the SRT was maintained in the appropriate range of 15–18 d, enhancing the capacity of denitrifiers to reduce N2O. These operational strategies are highly consistent with N2O mitigation measures reported for full-scale WWTPs [41,42].
Combined with the correlation results (Section 3.5), the underlying mechanisms can be further explained from a microbiological perspective. (1) Completeness of denitrification: although the influent BOD5/TN of 2.31 is far below the level at which carbon is sufficient for denitrification, the correlation analysis showed that N2O flux in the anoxic tank was significantly negatively correlated with the IRR (r = −0.36, p < 0.05), indicating that a higher IRR promoted the complete reduction of N2O as an intermediate in the anoxic stage, thus preventing its accumulation and emission. (2) SRT within the balanced microbial window: an SRT of 15–18 d accommodates both the enrichment requirements of slow-growing nitrifiers and the activity of denitrifiers; the significantly negative correlation between N2O flux in the aerobic tank and SRT (r = −0.42, p < 0.01) confirms the effectiveness of this balance point. (3) Alleviation of DO-mediated inhibition: N2O flux in the aerobic tank was significantly positively correlated with DO (r = 0.53, p < 0.01); by maintaining DO stably at 2.0–3.0 mg/L, the plant avoided the N2O accumulation caused by suppressed N2O reductase activity at high DO (>3.5 mg/L). The combined effect of these three mechanisms places the N2O emission factor of this plant at the lowest end of the range of domestically measured values.
From a microbiological standpoint, these operating conditions may have shaped a microbial community structure favorable to low N2O emissions: an appropriate SRT ensured the stable enrichment of nitrifiers such as ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB), while a sufficiently reducing anoxic environment and carbon allocation maintained high N2O reductase activity in denitrifiers, allowing N2O to be reduced to N2 at the terminal step of denitrification rather than being released [5,6]. Future work combining high-throughput sequencing with functional gene abundance analysis (e.g., nirS/nirK, nosZ) would help verify these mechanistic hypotheses. The ammonia oxidation process itself, including pathways mediated by ammonia-oxidizing archaea, is an important source of N2O [43], which further supports the above mechanistic inference centered on nitrification–denitrification regulation.
In terms of the spatial distribution mechanism, the concentration of CH4 in the anaerobic tank is fully consistent with the biochemical mechanism of methanogenesis via anaerobic fermentation of organic matter under anaerobic conditions. N2O was enriched in the aerobic tank, mainly because ammonia oxidation in this stage generates substantial N2O as an intermediate, and excessively high DO inhibits the further reduction of N2O by denitrification. These spatial patterns are highly consistent with the field measurements reported by Deng et al. [44] for domestic A2O WWTPs, validating the reliability of the present monitoring data. Studies reporting systematic underestimation of CH4 emissions from US WWTPs [45] likewise indicate that direct measurement of CH4 fluxes in anaerobic units is an indispensable element in inventory accuracy.
It should be noted that the aforementioned national-scale studies reveal systematic overestimation on the basis of multi-plant averages, whereas the present study provides site-specific factors for a single representative plant in a water source area; the two are therefore complementary rather than mutually confirmatory. The divergence between domestic A2O measurements—some exceeding the IPCC default—and the significantly lower values reported here may arise from the combined effects of influent substrate (BOD5/TN of only 2.31, under which denitrification reduces N2O more completely), DO control strategy (stable at 2.0–3.0 mg/L), sludge age (15–18 d), and hydraulic loading (rainy-season dilution). In addition, the present measurements were obtained under the relatively high water temperatures of May–June; microbial metabolic rates decline at low temperatures, so the emission factors may shift, and winter measurements remain to be supplemented.

4.2. Analysis of GHG Emission Driving Factors

As shown by the correlation analysis in Table 2, the following relationships were identified.
(1)
Drivers of CH4 emissions: CH4 flux in the anaerobic tank was significantly positively correlated with COD loading (r = 0.58, p < 0.01) and significantly negatively correlated with DO (r = −0.32, p < 0.05), indicating that organic loading is the primary driver of CH4 production, whereas anaerobic conditions are a prerequisite for CH4 release. Water temperature also exerted a positive influence on CH4 flux (r = 0.45, p < 0.01), consistent with the biochemical principle that microbial metabolic rates increase with temperature.
(2)
Drivers of N2O emissions: N2O flux in the aerobic tank was significantly positively correlated with DO (r = 0.53, p < 0.01) and significantly negatively correlated with both SRT (r = −0.42, p < 0.01) and the IRR (r = −0.45, p < 0.01). This indicates that although a high DO favors nitrification, it promotes N2O accumulation and inhibits its further reduction; longer SRT and a higher IRR favor the reduction of N2O by denitrifying bacteria, thereby lowering N2O emissions. N2O flux in the anoxic tank was significantly correlated with TN loading (r = 0.45, p < 0.01) and with the IRR (r = −0.36, p < 0.05), suggesting that increasing the IRR can partly alleviate N2O accumulation when carbon is insufficient [42]. (3) Observed DO window: within the 30-day record, aerobic N2O flux was positively correlated with DO (Spearman r = 0.53, p < 0.01; Table 2), and the plant’s design set point of 2.0–3.0 mg/L coincided with nitrification efficiency above 90%. This is an observed, plant-specific operating window, not an optimum: no controlled DO trial, no threshold comparison at 3.5 mg/L, and no multi-objective optimisation of effluent quality, energy use and GHG flux were performed.

4.3. Assessment of Synergistic Pathways for Pollutant Reduction and Carbon Abatement

4.3.1. Indirect GHG Emission Reduction Benefits of Distributed Photovoltaic (PV) Power Generation

Field measurements and operational data indicate that the accounting system based on the IPCC default methodology may significantly overestimate the actual emission levels of CH4 and N2O when applied to wastewater treatment plants (WWTPs) with low-strength wastewater in China. This deviation provides untapped optimization potential for the implementation of precise pollutant reduction and carbon abatement strategies [20,46]. In terms of indirect emission reduction, the distributed photovoltaic (PV) power generation system (with an installed capacity of approximately 1200 kWp) commissioned at the plant in November 2024 has demonstrated stable benefits. 85% of PV power output is concentrated during daytime hours from 8:00 to 18:00, which matches the high-load operation period of the aeration system (with a load matching rate of 79%), resulting in high on-site utilization efficiency of green electricity. If an intelligent control system is further adopted to prioritize the allocation of PV power to adjustable loads such as aeration and mixing, there is still room for improvement in the environmental benefits of PV power. The GHG emission reduction potential of WWTPs coupled with renewable energy has been validated by international case studies [47,48].
From the perspective of economic sustainability, the PV system can replace approximately 81,000 kWh of grid electricity per month. Based on a rough estimate of the general industrial and commercial electricity price in Hubei Province, it can save more than 500,000 RMB in electricity bills annually. With reference to the domestic construction cost of distributed PV (approximately 3.5–4.0 RMB per Wp) and the plant’s installed scale (1200 kWp), the static investment payback period is about 7–9 years. Positive net economic benefits can be achieved within the 25-year operation cycle, giving it engineering promotion value. Meanwhile, it is necessary to objectively view the environmental trade-offs of PV power generation: there are embodied carbon emissions in the manufacturing, transportation, and end-of-life disposal of PV modules, and module cleaning also consumes a certain amount of water resources. However, compared with the cumulative total emission reductions over decades of system operation, the aforementioned upfront environmental loads account for a relatively small proportion and do not alter the net emission reduction conclusion of the PV pathway. Overall, the “PV power generation + refined operational control” pathway is sustainable in both environmental and economic dimensions.
It should be noted that the above observational before–after comparison has certain limitations for causal inference: the pre-PV period (January–October) spans the high-flow summer season, whereas the post-PV period (November–May of the following year) spans the low-flow winter season; the seasonal composition of the two periods differs, and the seasonal variations in influent flow, water temperature, and pollutant loading may be confounded with the PV effect. The present study partly mitigates the principal confounders by means of two lines of evidence: (1) the comparison uses the share of energy-related emissions rather than the absolute quantity, which removes the scale effect of flow but not the differences in pollutant loading and chemical dosing documented in Table A3; and (2) the effluent quality continuously met the Class1A discharge standard throughout the study period, and no major adjustment was made to the operational strategy, so that systematic effects of changes in operation and management on energy consumption can be excluded. Nevertheless, in the absence of a concurrent control plant, the 20.08% difference should still be interpreted as a significant correlation between PV generation and the decline in energy-related emissions rather than as a strict causal effect. A more rigorous difference-in-differences or interrupted time-series analysis is warranted in future research.
The practical constraints of the “PV + WWTP” model should also be acknowledged. PV generation is intermittent, with no output at night, whereas WWTPs must operate continuously; PV alone cannot achieve electricity self-sufficiency, and energy storage or intelligent energy scheduling systems are required. Water source protection zones impose strict limits on land use, landscape, and ecological disturbance within the plant, restricting the space available for PV panel installation. The temporal matching between PV output and aeration load also depends on fine-grained control. These constraints mean that PV is better suited to serving as an incremental mitigation measure, working together with refined operational control and localized factor correction to form an integrated decarbonization strategy for WWTPs in water source areas.

4.3.2. Direct GHG Emission Reduction Pathways of Refined Operational Control

Direct emission reduction should focus on N2O, the gas with the high global warming potential. Combining the results of the driver analysis in Section 4.2, this study proposes the following operational control pathways [49]: (1) DO control: maintaining DO at the plant’s existing set point of 2.0–3.0 mg/L was associated with a lower aerobic N2O flux (Section 4.2) and nitrification efficiency above 90%; excessive aeration should be avoided, although no controlled trial was conducted and the associated energy saving was not quantified. (2) SRT and internal recirculation: keeping SRT at 15–18 d and the IRR within 100–200% (Table 1) was associated with lower N2O flux (Table 2) and stable nitrification. Raising the IRR improves nitrate return and TN removal but increases recirculation pumping energy, DO carry-over into the anoxic zone and the loss of anoxic residence time; shortening the SRT risks nitrifier washout at low temperature, whereas lengthening it raises aeration and sludge-handling demand. These trade-offs were not quantified. (3) Influent carbon source management: in response to the carbon limitation indicated by the low influent BOD5/TN (2.31), reducing the dosage of external carbon sources through operational optimization (the plant ceased routine sodium acetate dosing from January 2024) can simultaneously lower drug-related emissions and sludge production. Based on the measured emission factors, the above refined control measures can achieve source-level reductions in direct emissions without additional capital investment.

4.3.3. Managerial GHG Emission Reduction Benefits of Localized Emission Factor Calibration

At the managerial level, localized calibration of the accounting methodology is itself an important “soft” emission-reduction measure. The measured emission factors in this study are markedly lower than the IPCC default values (44.4% for CH4 and only 4.3% for N2O). If regional carbon accounting directly applies the generic IPCC default values, the emission levels of this plant and of similar WWTPs would be overestimated by a factor of 2–10, leading to distorted attribution of mitigation responsibility and misinformed low-carbon investment decisions. It is recommended that localized emission factor databases be established preferentially in the South-to-North Water Diversion water source areas and in similar low-strength regions, and that these databases be incorporated into the dynamic annual update of inventories, so as to improve the accuracy of GHG statistics and accounting and to provide a reliable benchmark for mitigation performance assessment.
Compared with international experience, some European Union member states have already incorporated measured emission factors from WWTPs into the annual update mechanism of their national inventories, while some water source protection zones in the United States require WWTPs to adopt site-specific parameters in carbon assessment [8,11]. China’s South-to-North Water Diversion water source areas still lack a comparable institutional arrangement for factor localization, and the present study can provide a methodological and data basis for establishing such a system. Whole-plant carbon–energy coupling models and in situ tracer-based measurements are also effective tools for improving accounting accuracy [50,51], and can provide methodological support for the dynamic updating of localized inventories.

4.4. Comprehensive Sustainability Assessment

Integrating the results of this study, the sustainability significance of the aforementioned mitigation pathways can be evaluated from three dimensions: environmental, economic, and social. Environmental dimension: the localized emission factors correct an overestimation of 2–10-fold, bringing carbon accounting back to the true emission level; PV generation and refined control further reduce the actual emission intensity, contributing directly to Sustainable Development Goal (SDG) 13 (Climate Action) and SDG 6 (Clean Water and Sanitation). Economic dimension: the PV system has a simple payback period of approximately 7–9 years and can deliver a “decarbonization–cost reduction” win-win outcome over long-term operation; refined control requires no additional capital investment and satisfies the resource-efficiency requirements of SDG 12 (Responsible Consumption and Production). Social dimension: as the Danjiangkou Reservoir region is an important water source for hundreds of millions of people in the Beijing–Tianjin–Hebei–Henan region, low-carbon and stable operation of its WWTP reduces the risk of environmental pollution at the water source, carrying significant ecological security and social stability value. The synergy of the three dimensions indicates that precise accounting coupled with renewable energy is a feasible pathway toward sustainable development of the wastewater treatment sector. Systematic assessment of energy-self-sufficient WWTPs likewise shows that the synergy between operational optimization and energy recovery can simultaneously improve environmental and economic performance [52].

4.5. Research Limitations and Future Prospects

The present study has the following limitations. (1) Field flux monitoring was conducted only in May–June 2025, without continuous observation across all four seasons; the measured emission factors therefore cannot be taken as directly representative of annual operation, particularly as the low-temperature winter conditions were not covered. Seasonal extrapolation is therefore a major uncertainty (CV = 30% prior; Section 2.3.5). (2) This study examines a single WWTP in a water source protection zone, whose influent is predominantly domestic sewage and is low in strength; extrapolating the conclusions to other types of WWTPs across China is thus limited. (3) GHG emissions from the sludge handling and disposal stage were accounted for solely on the basis of IPCC modeling, lacking in situ measurements for the sludge unit. (4) The 17-month monthly GHG totals still rely on IPCC default factors and were not corrected using the short-term measured factors; the PV mitigation benefit was estimated from theoretical generation output without accounting for extreme weather and nighttime operating conditions. (5) The DO window and the SRT/IRR settings are single-plant observations without a controlled operational trial or a multi-objective optimisation of effluent quality, energy use and GHG flux; their generalizability requires validation under different water quality and temperature conditions. These caveats are structural rather than minor: the chamber-to-tank upscaling of fluxes, possible temporal autocorrelation in the 30-day series, uncertain chemical emission factors, the assumed zero sludge methane correction factor (MCF), and the observational before–after attribution of the PV benefit may each shift both the absolute inventory and the ranking of mitigation measures; the reported totals and that ranking should therefore be interpreted as conditional, and as indicative rather than definitive. The Monte Carlo 95% CI consequently represents a conditional lower bound on total uncertainty.
Future research directions include: constructing a localized emission factor database that encompasses seasonal variation and process fluctuation scenarios; conducting systematic comparative studies across different process types and water quality conditions; and developing machine-learning-based real-time prediction models for GHG emissions to support refined operational control. For policymakers, it is recommended that localized emission factors be incorporated into regional carbon accounting guidelines and that the “PV + refined control” model be promoted with priority in water source protection zones. For WWTP operators, the observed DO (2.0–3.0 mg/L) and SRT (15–18 d) settings may serve as a plant-specific reference pending site-specific validation, and a monthly carbon emission ledger is recommended for routine carbon management.
It should be specifically noted that the conclusions of this study apply only to municipal WWTPs that adopt the A2O process, receive influent with COD concentrations below 300 mg/L, and discharge effluent meeting the Grade 1A standard of GB 18918–2002. If the generic IPCC default values were applied directly, the emission levels of similar WWTPs in this region could be overestimated by a factor of 2–23. This constitutes the most important policy implication of the present study: priority should be given to locally measured emission factors when correcting accounting results, thereby improving the accuracy of GHG inventories. Because inputs were sampled independently and the attribution uses a one-group-at-a-time conditional variance decomposition rather than a full Sobol’ total-effect index, the reported 68% is a first-order, conditional contribution.

5. Conclusions

(1)
Based on 17 months of operational data and the IPCC inventory method, a gate-to-gate GHG inventory was constructed for the A2O wastewater treatment plant serving the Danjiangkou water source area: the average monthly emission was 562.44 t CO2-eq and the emission intensity was 0.31 kg CO2-eq/m3, about 31% below the nationwide mean of 0.45 kg CO2-eq/m3 reported for 247 full-scale WWTPs across China; energy-related indirect emissions accounted for 45.54% of the total and constituted the largest single emission source.
(2)
In situ continuous monitoring in May–June 2025 yielded site-specific emission factors: a mean CH4 factor of 0.00333 kg CH4/kg COD (44.4% of the IPCC default) and a mean N2O factor of 0.000687 kg N2O-N/kg TN (4.3% of the IPCC default). The anaerobic tank was the main CH4-release unit (1.91–3.32 g/m2·d), whereas the aerobic tank was the largest N2O-release unit (0.049–0.242 g/m2·d). Monte Carlo uncertainty analysis showed that the selection of emission factors (contributing 68%) is the primary source of uncertainty in the accounting results.
(3)
Spearman correlation analysis identified the key drivers of GHG emissions: CH4 emissions are governed mainly by COD loading and DO, whereas N2O emissions are regulated mainly by DO, SRT, and the internal recirculation ratio. At this plant, DO maintained at 2.0–3.0 mg/L was associated with lower N2O flux while nitrification efficiency remained above 90%.
(4)
The share of energy-related emissions was lower after PV commissioning (49.64% before vs. 39.67% after), and average monthly purchased grid electricity decreased by approximately 81,000 kWh; because the two periods differ seasonally and no concurrent control plant was available, this observational before–after comparison provides correlational rather than causal evidence (Section 4.3.1).
(5)
The above conclusions apply principally to A2O-process municipal WWTPs in water source protection zones characterized by low-strength, predominantly domestic influent and compliance with the Class 1A discharge standard; extrapolation to other process types and water quality conditions should be undertaken with caution.

Author Contributions

Z.Y.: Investigation, Writing—original draft preparation. M.L.: Conceptualization, Methodology, Writing—review and editing. J.G.: Methodology, Writing—review and editing, Project administration and Funding acquisition. W.Z.: Data curation, Formal analysis. L.W.: Resources, Supervision. F.G.: Resources, Writing—review and editing. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Science and Technology Project of Hubei Province (grant no. 2026CSA043); the National Natural Science Foundation of China (grant no. 51579092); and the Major Science and Technology Project of China Energy Engineering Corporation (grant no. CEEC2023-ZDYF-09).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

The authors thank the Danjiangkou Municipal Wastewater Treatment Plant for providing long-term operational data and supporting the field monitoring, and thank Wuhan Ganwei Technology Co., Ltd. for their assistance with the operation and maintenance of the online monitoring equipment.

Conflicts of Interest

The authors declare no conflicts of interest. Authors Lei Wu and Feng Guo was employed by Gezhouba Group Ecological Environmental Protection Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The authors declare that this study received funding from China Energy Engineering Corporation Limited (Project No. CEEC2023-ZDYF-09). The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.

Abbreviations

The following abbreviations are used in this manuscript:
AbbreviationDefinition
A2O/AAOAnaerobic–Anoxic–Oxic
AOBAmmonia-oxidizing bacteria
AR6Sixth Assessment Report (IPCC)
BOD55-day biochemical oxygen demand
CIConfidence interval
CODChemical oxygen demand
CRDSCavity ring-down spectroscopy
CVCoefficient of variation
DODissolved oxygen
EFEmission factor
GBChinese national standard (Guobiao; GB 18918—2002)
GHGGreenhouse gas
GWPGlobal warming potential
HRTHydraulic retention time
IPCCIntergovernmental Panel on Climate Change
IRRInternal recirculation ratio
MCFMethane correction factor
MCF_ADMCF for anaerobic sludge digestion
NOBNitrite-oxidizing bacteria
N2O-NNitrous oxide expressed as nitrogen
PACPolyaluminum chloride
ppbParts per billion
PVPhotovoltaic
RMBRenminbi (Chinese yuan)
SDGSustainable Development Goal
SRTSludge retention time
TNTotal nitrogen
TPTotal phosphorus
WTWater temperature
WWTPWastewater treatment plant

Appendix A

Table A1. Comparison of key water-quality and operating variables between the monitoring period and the full 17-month operational record.
Table A2. Distributions, numerical parameters and rationale for the inputs of the Monte Carlo uncertainty analysis.
Table A3. Absolute monthly greenhouse gas emissions and activity data before and after photovoltaic commissioning.
Table A4. Daily CH4 and N2O emission fluxes and descriptive statistics from the in-situ chamber campaign (1–31 May 2025).
Spatial heterogeneity and episodic emissions: three replicate chamber positions were set in each tank and averaged into one daily unit mean (Section 2.4.1), so within-tank between-position variability is not resolved by the daily series; the chamber footprint (0.031415 m2) is small relative to the tank surface, and chamber-to-tank upscaling remains a limitation. Continuous synchronous 24-h records were retained on every campaign day, so short-lived release events appear as daily peaks: 5 of the six series contain one or two days exceeding mean + 2 SD (Panel A, last column) and day-to-day CVs span 10–43%.
Temporal profile: Panel B gives the complete daily series; early-/mid-/late-campaign means (days 1–10/11–20/21–31) were 3.097/2.996/2.720 for anaerobic CH4 and 0.098/0.104/0.148 for aerobic N2O, with no monotonic trend common to all six series. These statistics describe the campaign window only and are not annual estimates: winter conditions were not covered (Section 4.5), and the 17-month totals were computed exclusively with IPCC default factors (Section 2.4), so no annual extrapolation is implied. Abbreviations: SD, standard deviation; CI, confidence interval; CV, coefficient of variation.

References

  1. Kim, K.; Chang, M.; Lee, J. Estimation of greenhouse gas emissions from a hybrid wastewater treatment plant. J. Clean. Prod. 2015, 95, 117–123. [Google Scholar] [CrossRef] [Scilit]
  2. Sanchez, R.L.; Mazzotti, D.L. Assessment of carbon dioxide removal potential via BECCS in a carbon-neutral Europe. Energy Environ. Sci. 2021, 14, 3086–3097. [Google Scholar] [CrossRef] [Scilit]
  3. McNicol, G.; Jeliazovski, J.; François, J.J.; Kramer, S.; Ryals, R. Climate change mitigation potential in sanitation via off-site composting of human waste. Nat. Clim. Change 2020, 10, 545–549. [Google Scholar] [CrossRef] [Scilit]
  4. Liu, J. Research progress on greenhouse gas emissions from urban wastewater treatment plants in China. Acta Sci. Circumst. 2006, 26, 405–411. [Google Scholar]
  5. Kampschreur, M.J.; Temmink, H.; Kleerebezem, R.; Jetten, M.S.; van Loosdrecht, M.C. Nitrous oxide emission during wastewater treatment. Water Res. 2009, 43, 4093–4103. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Mannina, G.; Ekama, G.A.; Capodici, M.; Cosenza, A.; Di Trapani, D.; Ødegaard, H.; van Loosdrecht, M.M. Influence of carbon to nitrogen ratio on nitrous oxide emission in an IFAS MBR plant. J. Clean. Prod. 2018, 176, 1078–1090. [Google Scholar] [CrossRef] [Scilit]
  7. Zhao, X.; Jin, X.K.; Guo, W.; Zhang, C.; Shan, Y.L.; Du, M.X.; Tillotson, M.R.; Yang, H.; Liao, X.W.; Li, Y.P. China’s urban methane emissions from municipal wastewater treatment plants. Earth’s Future 2019, 7, 480–490. [Google Scholar] [CrossRef] [Scilit]
  8. Lam, K.L.; van der Hoek, J.P. Low-carbon urban water systems: Opportunities beyond water and wastewater utilities? Environ. Sci. Technol. 2020, 54, 14854–14861. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Wang, D.; Ye, W.; Wu, G.; Li, R.; Guan, Y.; Zhang, W.; Wang, J.; Shan, Y.; Hubacek, K. Greenhouse gas emissions from municipal wastewater treatment facilities in China from 2006 to 2019. Sci. Data 2022, 9, 317. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Tao, X.; Wang, C.W. Assessment of greenhouse gas emissions from wastewater treatment plants. J. Tsinghua Univ. (Nat. Sci.) 2012, 52, 5. [Google Scholar]
  11. Delanka-Pedige, H.M.K.; Munasinghe-Arachchige, S.P.; Abeysiriwardana-Arachchige, I.S.A.; Nirmalakhandan, N. Wastewater infrastructure for sustainable cities. Int. J. Sustain. Dev. World Ecol. 2021, 28, 203–209. [Google Scholar] [CrossRef] [Scilit]
  12. Ma, J.; Ni, X.; Cai, C.; Da, Y.; Hu, K.; Guo, R.; Liu, J.; Peng, K.; Liu, E.; Huang, X. Insights into greenhouse gas emissions from a wastewater treatment plant in vulnerable water areas of China. Sci. Total Environ. 2023, 902, 166017. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Zhu, L.; Wang, C.; Huang, N.; Fu, Y.; Yan, Z. Developing an indicator system to monitor city’s sustainability integrated local governance: A case study in Zhangjiakou. Sustainability 2022, 14, 5047. [Google Scholar] [CrossRef] [Scilit]
  14. Tian, Y.; Liu, S.; Guo, Z.; Wu, N.; Liang, J.; Zhao, R.; Hao, L.; Zeng, M. Insight into greenhouse gases emissions and energy consumption of different full-scale wastewater treatment plants via ECAM tool. Int. J. Environ. Res. Public Health 2022, 19, 13387. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Ministry of Housing and Urban-Rural Development of the PRC. 2024 Statistical Yearbook of Urban Construction; Ministry of Housing and Urban-Rural Development of the PRC: Beijing, China, 2025.
  16. Gustavsson, D.J.I.; Tumlin, S. Carbon footprints of Scandinavian wastewater treatment plants. Water Sci. Technol. 2013, 68, 887. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Liu, B.; Wei, Q.; Zhang, B.; Bi, J. Life cycle GHG emissions of sewage sludge treatment and disposal options in Tai Lake Watershed, China. Sci. Total Environ. 2013, 447, 361. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Yoshida, H.; Mønster, J.; Scheutz, C. Plant-integrated measurement of greenhouse gas emissions from a municipal wastewater treatment plant. Water Res. 2014, 61, 108. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Ma, X.-W.; Weng, H.-X.; Su, M.-H.; Pan, L. Drying sewage sludge using flue gas from power plants in China. Environ. Earth Sci. 2012, 65, 1841–1850. [Google Scholar] [CrossRef] [Scilit]
  20. Song, C.; Zhu, J.-J.; Wang, J.-L.; Moore, D.P.; Zondlo, M.A.; Ren, Z.J. Oversimplification and overestimation of nitrous oxide emissions from wastewater treatment plants. Nat. Sustain. 2024, 7, 1348–1358. [Google Scholar] [CrossRef] [Scilit]
  21. Li, H.-Y.; You, L.-F.; Du, H.; Yu, B.; Lu, L.; Zheng, B.; Zhang, Q.; He, K.; Ren, N. Methane and nitrous oxide emissions from municipal wastewater treatment plants in China. Environ. Sci. Ecotechnol. 2024, 20, 100345. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. GB 18918-2002; State Environmental Protection Administration of China. Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant. China Environmental Science Press: Beijing, China, 2002.
  23. Ministry of Ecology and Environment of the People’s Republic of China. Guidelines for the Development of Provincial Action Plans to Reach the Peak in Carbon Dioxide Emissions; Ministry of Ecology and Environment: Beijing, China, 2021.
  24. IPCC. 2019 Refinement to the 2006 IPCC Guidelines for National Greenhouse Gas Inventories; Volume 2 Energy; Calvo Buendia, E., Tanabe, K., Kranjc, A., Baasansuren, J., Fukuda, M., Ngarize, S., Osako, A., Pyrozhenko, Y., Shermanau, P., Federici, S., Eds.; IPCC: Geneva, Switzerland, 2019. [Google Scholar]
  25. IPCC. Refinements to the 2006 IPCC Guidelines for National Greenhouse Gas Inventories; IPCC: Geneva, Switzerland, 2019. [Google Scholar]
  26. Goliopoulos, N.; Mamais, D.; Noutsopoulos, C.; Dimopoulou, A.; Kounadis, C. Energy consumption and carbon footprint of Greek wastewater treatment plants. Water 2022, 14, 320. [Google Scholar] [CrossRef] [Scilit]
  27. IIqbal, A.; Zan, F.; Siddiqui, M.A.; Nizamuddin, S.; Chen, G. Integrated treatment of food waste with wastewater and sewage sludge: Energy and carbon footprint analysis with economic implications. Sci. Total Environ. 2022, 825, 154052. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Marinelli, E.; Radini, S.; Foglia, A.; Lancioni, N.; Piasentin, A.; Eusebi, A.L.; Fatone, F. Validation of an evidence-based methodology to support regional carbon footprint assessment and decarbonisation of wastewater treatment service in Italy. Water Res. 2021, 207, 117831. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Jin, W.-Y.; Bai, X.; Shi, Y.; Chen, D.; Gu, Y. Identification of greenhouse gas emission trends and driving factors in urban wastewater treatment plants in China. Res. Environ. Sci. 2024, 37, 650–660. [Google Scholar]
  30. IPCC. Climate Change 2021: The Physical Science Basis. Contribution of Working Group I to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change; Cambridge University Press: Cambridge, UK, 2021. [Google Scholar]
  31. Li, H.-Y.; You, L.-F.; Du, H. N2O emission characteristics and factor correction of 27 full-scale AAO wastewater treatment plants in China. China Environ. Sci. 2024, 44, 3665–3674. [Google Scholar]
  32. Wang, S.-Y.; Yang, Y.; Li, R. N2O emission measurement and influencing factors in AAO wastewater treatment plants in central China. Environ. Eng. 2024, 42, 287–293, 300. [Google Scholar]
  33. Zhang, C.-X.; Guo, W.; Shan, Y.-L. N2O emission characteristics and reduction control of low C/N ratio AAO process. Water Treat. Technol. 2024, 50, 112–117. [Google Scholar]
  34. Xu, A.; Wu, Y.-H.; Chen, Z.; Hao, S.-R.; Hu, H.-Y. Analysis on the Construction and Operation Status of Urban Sewage Treatment Plants in the Yellow River Basin. Water Wastewater Eng. 2022, 58, 27–36. [Google Scholar]
  35. Cao, Y.-S.; Tang, J.-G.; Henze, M.; Yang, X.P.; Gan, Y.P.; Li, J.; Kroiss, H.; Van Loosdrecht, M.C.M.; Zhang, Y.; Daigger, G.T. The Leakage of Sewer Systems and the Impact on the ‘Black and Odorous Water Bodies’ and WWTPs in China. Water Sci. Technol. 2019, 79, 334–341. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Sun, Y.; Chen, Z.; Wu, G.-X.; Wu, Q.; Zhang, F.; Niu, Z.; Hu, H.Y. Characteristics of Water Quality of Municipal Wastewater Treatment Plants in China: Implications for Resources Utilization and Management. J. Clean Prod. 2016, 131, 1–9. [Google Scholar] [CrossRef] [Scilit]
  37. Wang, H.-T.; Yang, Y.; Keller, A.A.; Li, X.; Feng, S.; Dong, Y.-N.; Li, F. Comparative analysis of energy intensity and carbon emissions in wastewater treatment in USA, Germany, China and South Africa. Appl. Energy 2016, 184, 873–881. [Google Scholar] [CrossRef] [Scilit]
  38. Chen, J.; Ao, Z.; Chen, H.; Wang, Y.; Jiang, M.; Qi, L.; Liu, G.; Wang, H. Analyzing greenhouse gas emissions and influencing factors of 247 actual wastewater treatment plants in China using emission factor and operational data integrated methods (ODIM). Environ. Sci. Pollut. Res. 2024, 31, 37387–37403. [Google Scholar] [CrossRef] [Scilit]
  39. Liao, X.-W.; Tian, Y.-J.; Gan, Y.-W.; Ji, J.-P. Quantifying Urban Wastewater Treatment Sector’s Greenhouse Gas Emissions Using a Hybrid Life Cycle Analysis Method—An Application on Shenzhen City in China. Sci. Total Environ. 2020, 745, 141176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Pan, T.-Y. Study on the Greenhouse Gas Emission Characteristics and Influencing Factors of Underground Wastewater Treatment Systems. Master’s Thesis, Harbin Institute of Technology, Harbin, China, 2023. [Google Scholar]
  41. Zaborowska, E.; Lu, X.; Makinia, J. Strategies for mitigating nitrous oxide production and decreasing the carbon footprint of a full-scale combined nitrogen and phosphorus removal activated sludge system. Water Res. 2019, 162, 53–63. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  42. Yan, X.; Han, Y.-P.; Li, Q.-L.; Sun, J.-H.; Su, X.-F. Impact of Internal Recycle Ratio on Nitrous Oxide Generation from Anaerobic/Anoxic/Oxic Biological Nitrogen Removal Process. Biochem. Eng. J. 2016, 106, 11–18. [Google Scholar] [CrossRef] [Scilit]
  43. Wu, L.; Chen, X.-M.; Wei, W.; Liu, Y.; Wang, D.-B.; Ni, B.-J. A Critical Review on Nitrous Oxide Production by Ammonia-Oxidizing Archaea. Environ. Sci. Technol. 2020, 54, 9175–9190. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  44. Zheng, X.-Y.; Hu, T.-X.; Deng, X.-C.; Tao, J.-Q.; Gong, Y.-P.; Yao, X.-Y.; Fan, Y.; Lin, T.; Chen, W.; Wang, D.-W. Carbon Emission Accounting, Influencing Factors, and Carbon Reduction Pathways in Typical A2/O Process Municipal Wastewater Treatment Plants. Environ. Eng. 2026, 44, 177–188. [Google Scholar]
  45. Moore, D.P.; Li, N.P.; Wendt, L.P.; Castañeda, S.R.; Falinski, M.M.; Zhu, J.-J.; Song, C.; Ren, Z.J.; Zondlo, M.A. Underestimation of Sector-Wide Methane Emissions from United States Wastewater Treatment. Environ. Sci. Technol. 2023, 57, 4082–4090. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  46. Sun, C.; Liu, Y.; Ciais, P.; Broquet, G.; Zheng, B.; Wang, H.; Chen, H. Measurement-based assessment reveals key drivers and mitigation potential of methane emissions from China’s wastewater treatment. Sci. Adv. 2026, 12, eadc0536. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  47. Chen, X.; Zhou, W. Economic and ecological assessment of photovoltaic systems for wastewater treatment plants in China. Renew. Energy 2022, 191, 852–867. [Google Scholar] [CrossRef] [Scilit]
  48. Alrbai, M.; Al-Dahidi, S.; Al-Ghussain, L.; Alahmer, A.; Hayajneh, H. Minimizing grid energy consumption in wastewater treatment plants: Towards green energy solutions, water sustainability, and cleaner environment. Sci. Total Environ. 2024, 926, 172139. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Wang, J.; Zhang, Z.; Li, H.; Liu, C.; Wang, Z.; Jia, Y.; Qi, F.; Li, Q. Synergistic benefit assessment of reductions in pollution and in CO2 emission and green low-carbon operation strategies for urban recycled water plant with A2O process. J. Beijing Norm. Univ. (Nat. Sci.) 2026, 62, 389–401. [Google Scholar]
  50. Du, H.; Yu, B.; Chen, J.; Ren, N.; Lu, L. More applicable quantification of non-CO2 greenhouse gas emissions from wastewater treatment plants by on-site plant-integrated measurements. Sci. Total Environ. 2024, 929, 172598. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  51. Manheim, D.C.; Karimi, S.; Delkash, M.; Imhoff, P.; Yazdani, R. Multi-scale UAV, flux-chamber, and point-source measurement framework for facility-wide greenhouse gas and air pollutant emissions assessment from wastewater treatment operations. Water Res. 2026, 300, 125950. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  52. Callahan, J.L.; Douthwaite, T.; Esqueda, D.; Newhart, K.; Pfluger, A.R. Technoeconomic Analysis of Energy-Producing Small-Scale Wastewater Resource Recovery Facility Using Anaerobic Codigestion and Renewable Energy Technologies. ACS EST Eng. 2026, 6, 222–234. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.