Abstract
PocketQube picosatellites built from commercial off-the-shelf components are widely used in educational and demonstration missions, yet experimental data on their on-board systems under qualification loads, and lifetime estimates based on such data, are scarce. This study aims to verify the operation of the on-board system of the PocketSat picosatellite (PocketQube 1.5P) under simulated launch and space conditions and to estimate its remaining useful life from the test data. The experimental model underwent thermal cycling (25 cycles between −30 and +60 °C), thermal vacuum tests, and sine and random vibration at the test program levels (5.57 g RMS). The on-board system operated nominally throughout all tests. The thermal time constant in vacuum was 0.6–1.2 h; the MPU6050 accelerometer reading drifted by 4.0% at the cold level over 25 cycles; the first natural frequency exceeded 600 Hz and shifted by no more than 2.73%. Using an engineering end-of-life threshold based on the accelerometer datasheet tolerance, a health index model gives an estimated remaining useful life of the accelerometer channel of 0.7–2.0 years in a 500 km orbit after post-test calibration. This single-unit estimate depends on the assumed degradation law and model parameters and should be confirmed by further testing.