Skip to Content
Applied SciencesApplied Sciences
  • Article
  • Open Access

27 November 2026

20 Pages

Dust Generation During Milling of Grey Cast Iron: Parametric Modeling of Particle Size Distribution

,
,
and
Department of Occupational Safety and Environmental Protection, Don State Technical University, Rostov-on-Don 344000, Russia
*
Author to whom correspondence should be addressed.

Highlights

Public health relevance—How does this work relate to a public health issue?
•
Machining of grey cast iron can release fine particles; inhaled dust is associated with chronic respiratory diseases.
•
This study provides a systematic PSD dataset for settled cast iron milling dust under the studied conditions, supporting exposure-assessment research.
Public health significance—Why is this work of significance to public health?
•
Mass-based PSD characterization can inform the design of local exhaust ventilation and filtration; direct reduction in PM10/PM2.5 exposure was not measured here.
•
Under the studied conditions, air cooling was associated with a shift towards smaller particles; this is an observed association, not an isolated causal effect.
Public health implications—What are the key implications or messages for practitioners, policy makers and/or researchers in public health?
•
The Weibull (Rosin–Rammler) distribution can be considered a conservative engineering approximation for CFD-DEM input after validation; it predicts more fine particles than lognormal.
•
The parameterized PSD models can serve as input data for dust-control design and CFD-DEM after validation with suspended dust; they do not directly provide evidence for health standards.

Abstract

Particle size distribution (PSD) of dust generated during machining is a key parameter for designing dust control systems. In this study, 90 dust samples were collected from two milling machines under three milling modes, with and without air supply, at five points in the working area. The study is limited to grey cast iron grade SCH20 and to the investigated milling conditions. Sieve analysis was used, with laser diffraction (LALLS) validation for ten samples. The dust showed high polydispersity: the calculated number-based mean particle size ranged from 16.6 to 228 µm. In the investigated conditions, samples collected with air supply showed a smaller median particle size (70–120 μm vs. 50–70 μm); however, because different machines, tools and cutting parameters were used, this is interpreted as an observed effect rather than an isolated causal factor of air cooling. Comparison of the methods showed agreement in mass representation (5–7% discrepancy). However, in number-based representation, LALLS detected up to 35% of particles below the sieve analysis lower limit (26 μm). Calculated number-based PSDs were approximated using Weibull and lognormal distributions. The lognormal model provided slightly higher statistical accuracy (RMSE 2.4 vs. 2.9). Nevertheless, within the investigated conditions, the Weibull distribution is a provisional modeling option as a conservative engineering approximation for practical tasks. Its extrapolation below 26 μm predicts a higher proportion of fine fractions than the lognormal model; however, direct measurements of PM10, PM2.5 and PM1 were not performed, and these estimates are preliminary and require validation. Parameterized PSD models are presented for each milling mode and sampling point.

1. Introduction

Mechanical processing of brittle metals is accompanied by the intense release of solid dust particles, which can lead to a high concentration of aerosol in the air of the working area. This can cause two main sets of problems: technological issues such as reduced product quality and accelerated wear of tools and equipment, and sanitary and environmental concerns related to harmful effects on the health of personnel and the environment, especially small fractions of PM10, PM2.5, PM1 [1,2,3,4,5]. One way to partially solve this problem is through the use of cutting fluids. However, their use can also lead to the formation of oil mist, which worsens working conditions [6,7,8,9].
On a global health scale, exposure to industrial particles, gases, and fumes continues to be a significant factor in occupational morbidity and mortality. According to estimates from the World Health Organization (WHO) and the International Labour Organization (ILO), it caused approximately 450,000 deaths between 2000 and 2016 [10,11]. The most common cause of death among occupational diseases is chronic obstructive pulmonary disease, which is directly linked to the inhalation of dust and aerosols. Current statistical reviews and reports continue to highlight the significant contribution of respiratory diseases associated with dust inhalation to occupational mortality, particularly in certain regions of the world [12,13].
An analysis of the available literature revealed that most of these studies were devoted to dust generated in foundries [14], during the production of building materials [15], in the mining, coal, and chemical industries [16,17], in the production of nanomaterials [18], and in the processing and storage of agricultural products [19]. At the same time, the formation of aerosols during the mechanical processing of brittle metals such as grey cast iron was discussed in the literature primarily in the context of powder production for additive manufacturing [20,21]. However, these works focused on the active crushing of waste into standardized powder.
The lack of detailed data on particle sizes of such dust limits the possibility of using modern tools for designing dust control systems (ventilation, capture and filtration), such as CFD-DEM (computing fluid dynamics—discrete element modeling) and other numerical models used in trajectory prediction and aerosol capture [22,23,24,25,26,27]. One of the key input parameters of such models is the particle size distribution (PSD), as it determines the aerodynamic properties of particles and their behavior in the air. In addition, knowledge of PSD is necessary for a correct assessment of the effectiveness of the developed solutions.
Parametric models are widely used in PSD description tasks, engineering calculations, and numerical modeling. The Weibull (Rosin–Rammler) distribution adequately describes the accumulation of small fractions and the reduction in large fractions during material destruction. This distribution is used, for example, to describe the PSD of products of rock crushing, as well as fragmentation of materials during blasting [28,29,30,31,32,33]. The lognormal distribution is used for dispersed phases with a multiplicative nature of crushing, i.e., formed by successive crushing events. It is successfully applied to describe the PSD of atmospheric aerosols, aqueous suspensions, and building materials [34,35,36]. In some cases, other distributions are used to describe powders: normal, log-logistic, Rayleigh, Boltzmann, Gamma, and Pareto distributions, as well as finite and bicomponent functions [37,38,39].
At the same time, there is no unified approach in the literature to choosing the optimal PSD model for the milling processes of grey cast iron, which is characterized by a combination of a brittle fracture mechanism, high deformation rates, and the intensive formation of fine particles.
This research is of practical significance for enterprises with a low level of automation, where employees are directly exposed to harmful effects and massive modernization of equipment is difficult due to economic constraints. In such circumstances, local and economic air purification systems based on accurate empirical data on the PSD of dust can be a technical solution [40].
The identified scientific and practical gaps in existing research indicate the need for a more systematic PSD analysis of dust particles generated during machining of brittle metals. This study stands out from most published papers due to its detailed examination of samples based on milling modes, tool types, and sampling points.
The aim of the research was to experimentally determine the PSD of dust generated during the milling of grey cast iron in different modes, with an assessment of the parameters that affected the patterns of particle formation. We also aimed to develop a mathematical model that described the obtained PSD as key input data for CFD DEM simulation of dust propagation and capture under industrial conditions.
In this work:
•
We obtained systematized PSD data on dust generated during the milling of grey cast iron for the first time, with the analysis of the effects of milling modes, air cooling, and the spatial position of the sampling point;
•
We compared the results from sieve analysis with laser diffraction (LALLS);
•
We demonstrated the applicability of the Weibull distribution to describe the PSD of machine dust, which allowed us to directly apply the results in CFD-DEM modeling of aerosol transfer and in the design of dust control systems for grey cast iron.

2. Materials and Methods

2.1. Experimental Setup and PSD Measurements

From a methodological perspective, in the experimental part of the work, we identified two stages—production and laboratory. The first one was conducted in production conditions on two milling machines: a 6P13 knee milling machine (11 kW, without air cooling) and a 6A12A vertical milling machine (30 kW, with air cooling). The parameters of the air jet were not recorded.
The blanks were made of grey cast iron of the SCH20 grade, which was obtained through precision casting. The chemical composition of the material was as follows: C—3.5%, Si—2%, Mn—0.7%, S—0.15%, P—0.15%, Fe—the rest.
Face and end mills with diameters ranging from 30 to 125 mm were used. Three milling modes were studied, with different milling depths (from 0.5 to 4 mm), feed rates (from 80 to 160 mm/min) and spindle rotational speeds (from 200 to 800 rpm). Table 1 provides detailed data on the milling modes.
Table 1. Milling modes during sampling of experimental samples.
Sampling was conducted in the operators’ work area at pre-selected points:
•
Point 1: 0.1 m from the tool (directly at the milling cutter);
•
Points 2–3: 0.4–0.58 m (table surface);
•
Points 4–5: 0.78–1.1 m (operator’s breathing area).
The settled dust was collected from the surfaces of the table and floor. Sheets of silicone paper had been placed on them to prevent adhesion. Accordingly, all PSDs reported here refer to settled dust and not to airborne dust concentrations. The arrangement of the points is shown in Figure 1.
Figure 1. Arrangement of sampling points: (a) with air cooling of milling cutters; (b) without air cooling of milling cutters. 1–5 are sample point numbers, × is the milling cutter.
The experiment was conducted three times for each case studied. A total of 90 samples were collected (2 machines, 3 modes, 5 points, 3 repetitions).
For the laboratory PSD determination, a sieve analysis was used (dry screening, duration 15 min) on an Analysette 3 Spartan sieve shaker with a set of metal sieves ranging in size from 26 to 2000 µm (26, 50, 125, 250, 500, 900, 1500, 2000 µm). The pan fraction (<26 µm) was assigned a representative diameter of 16.6 µm calculated as the geometric mean of the lower sieve limit (26 µm) and an assumed lower bound of 10.6 µm; this fraction was included in normalization and in the mass-to-number conversion.
The control validation for fractions up to 500 µm was performed using the LALLS method (Laser Angular Light Scattering Spectroscopy) on a Fritsch Analysette 22 Nanotech analyzer (range 0.01–2000 µm, liquid dispersion—isopropanol, 30 with ultrasonic treatment). For this purpose, ten representative samples were selected, reflecting different modes and sampling points. The need to use LALLS was due to the sensitivity of the experiment to the PSD measurement method [41,42,43].

2.2. Data Processing and PSD Parametric Modeling

In the article, we clearly separate measured and calculated data. The measured quantities include mass-based PSD based on sieve analysis and LALLS for 10 samples. The calculated quantities include number-based PSD obtained by transformation (1), the parameters of the Weibull and lognormal distributions, extrapolation to the <26 μm region, and approximation quality metrics.
To obtain PSD models, the experimental data from the sieve analysis were pre-processed and approximated by parametric distribution functions.
Various approaches were used to determine the PSD [44]. The mass-based distribution of particles by size was used in the design and operation of dust removal and air purification systems. The number-based distribution of particles was used in modeling the dynamics of dust particles in the air and was considered in the work.
For aerosol transfer analysis and CFD-DEM simulation tasks, mass-based distributions were converted to number-based ones using ratio (1) and subsequent normalization:
f n d ∝ f m d d 3
where f m d —mass density distribution, f n d —quantitative distribution density, d —characteristic particle size.
This transformation assumes uniform density and quasi-spherical particles, i.e., the proportionality of the particle volume to the cube of the linear dimension. For angular/lamellar cast-iron particles, sieve-equivalent d3 can underestimate particle number and bias absolute number fractions; number-based results are therefore interpreted as relative/model-derived and require imaging or X-ray computed tomography (XCT) validation.
For each dimensional interval, the geometric mean of the values of the lower and upper boundaries of the sieve was used as a representative size. In order to increase the approximation stability, the modeling was performed using cumulative quantitative distributions. Cumulative distribution functions were constructed by integrating normalized quantitative densities by size.
The approximation of experimental cumulative PSDs was performed using two of the most commonly used analytical models: the Weibull distribution and the lognormal distribution.
Weibull distribution:
F x ; λ , k = 1 − e x p − x λ k , x ≥ 0 ,
f x = k λ ⋅ x λ k − 1 ⋅ exp − x λ k
where F ⋅ , f ⋅ —CDF (cumulative distribution function) and PDF (probability density function) respectively; k and λ —shape and scale distribution parameters, respectively.
Lognormal distribution:
F x ; μ , σ = 1 2 + 1 2 ⋅ e r f ln x − μ σ ⋅ 2 , x > 0 ,
f x =   1 x σ 2 π ⋅ exp − ln x − μ σ 2 2
where e r f ⋅ − error function; μ , σ —scale and shape distribution parameters.
The model parameters were estimated using the least squares method with minimizing RMSE (root mean squared error) between experimental and model cumulative curves.
The quality of the approximation was evaluated using a set of complementary quality metrics. The main criterion selected was the Akaike information criterion (AIC), which considered both the accuracy of the approximation and the complexity of the model. The root-mean-square error (RMSE) was used to quantify the deviation between the experimental and model cumulative functions. Coefficient of determination (R2) was used descriptively. Kolmogorov–Smirnov statistics (KS) were employed as a measure of the maximum discrepancy between experimental and model cumulative functions. Additionally, χ 2 statistics were calculated to assess agreement between distributions across the entire range of sizes.
The use of a multi-criteria approach in assessing the quality of models provided a reliable comparison between PSD analytical representations, allowing us to reasonably select the most appropriate model for aerosol transfer analysis and CFD-DEM modeling.

3. Results

3.1. Exploratory Data Analysis of PSD

The PSD of settled dust obtained as a result of sieve analysis for all experimental conditions showed a pronounced variability in shapes and parameters. Figure 2 presents calculated cumulative number-based PSDs derived from the measured mass distributions for all the samples studied. It also shows an envelope region, bounded by the 10th and 90th percentiles of the distributions.
Figure 2. Calculated cumulative number-based PSDs derived from measured mass distributions for all experimental samples. Thin lines show individual curves; the color area is limited by the 10th and 90th percentiles.
The cumulative curves differed significantly in their slope, median position, and the shape of their distribution tails. The greatest variation was observed for small and medium particle sizes (about 30–200 µm), whereas in the range of large fractions (>500–700 µm), the cumulative curves converged, forming a relatively narrow band of values. An analysis of the moments of the distributions revealed that the vast majority of samples had positive asymmetry and kurtosis exceeding the value of 3. Positive asymmetry indicates a right-sided “tail” of the distribution, i.e., the presence of a small proportion of particles larger than the modal/median size, while the bulk of the particles is concentrated in the region of smaller sizes. This should not be interpreted as a “shift towards smaller particles”: the median and mode may remain in the region of small fractions regardless of the sign of asymmetry.
Thus, experimental data demonstrated the absence of a single typical PSD shape and the presence of a significant variation in the parameters even under close milling conditions.

3.2. Influence of Milling Parameters and Air Cooling

The influence of milling conditions on the PSD characteristics was analyzed based on the mean particle diameter ⟨d⟩, coefficient of variation (CV), and coefficients of skewness and kurtosis of the number-based distributions. Figure 3a,b demonstrate boxplots for ⟨d⟩ and CV, respectively; the dotted line separates the modes with and without air cooling.
Figure 3. Boxplots for mean particle diameter ⟨d⟩ (a) and coefficient of variation CV (b) depending on the milling mode and the presence of air cooling. The dotted line separates modes without cooling (modes I, II, III on the left) and modes with cooling (modes I, II, III on the right). In each diagram: the center line is the median, the boundaries of the box are the first and third quartiles, and the “whiskers” are the outlier limits (1.5 × IQR), the black circles are the outliers. The dashed line separate cooling modes.
For all the studied modes under production conditions, the samples taken with compressed air supplied were characterized by a smaller observed average particle size. The median values of ⟨d⟩ for samples without cooling were 70–120 µm, whereas for samples with cooling, the median shifted to the range of 50–70 µm. At the same time, CV values changed from 1–1.6 for the modes without cooling to 1–1.2 for the modes with cooling, reflecting a narrowing of the particle size spectrum. The analysis of the skewness and kurtosis coefficients showed that the distributions obtained using air cooling had higher values of these coefficients compared to the modes without cooling. This indicated a more pronounced leptokurtic nature of the distributions. The exact data is provided in the Table 2.
Table 2. Statistics of the calculated number-based PSDs of all experimental sample.
To identify structural changes in the particle size distribution, Figure 4 illustrates the relationship between the coefficients of skewness and variation for all experimental samples.
Figure 4. Correlation between coefficient of variation (CV) and the coefficient of skewness for all experimental samples. The circles indicate samples without air cooling, and the squares indicate samples with air cooling.
There was a positive correlation between CV and skewness: the Pearson correlation coefficient was 0.32 for the entire sample. The range of values for modes without air cooling was higher than for modes with cooling. The samples with cooling were concentrated in the region of lower values of both CV and skewness.
Thus, changes in milling modes and the use of air cooling were accompanied by small changes in the mean particle diameter, distribution width, and shape of the PSD.

3.3. Spatial Distribution of Particles and Influence of the Sampling Point

The spatial heterogeneity of the settled dust was estimated based on the analysis of the number-based PSDs obtained for various sampling points located at different distances from the milling zone. Figure 5 shows the cumulative particle distributions aggregated over five sampling points. These are settled-dust samples and do not quantify airborne concentrations.
Figure 5. Cumulative number-based particle size distributions for different sampling points. Point 1—directly at the milling cutter (0.1 m); points 2–3—surface of the machine table (0.4–0.58 m); points 4–5—operator’s breathing area (0.78–1.1 m). Thick lines represent median curves for each point.
The PSD shape showed variations depending on the location of the sampling point. The remote points (4–5) were characterized by an increase in the cumulative fraction of small particles in the size range of less than 100 µm compared to point 1 (directly at the milling cutter). In the area of large fractions (more than 200 µm), the differences between the distributions were leveled.
To quantify the differences identified, we analyzed the parameters of the number-based distributions aggregated by sampling points (Figure 6).
Figure 6. Boxplots for mean particle diameter ⟨d⟩ (a) and coefficient of variation CV (b), depending on the sampling point (aggregated across all milling modes). The black circles are the outliers.
Mean values of ⟨d⟩ showed moderate changes depending on the sampling point: the median value decreased from 78 µm at point 1 to 62 µm at point 5. At the same time, there was significant inter-mode variation in the mean size values for all sampling points, overlapping the interpoint differences. The range of the interquartile range for ⟨d⟩ was 40–120 µm for most points. A similar pattern of variability was observed for the coefficient of variation: the median CV values increased from 1.15 at point 1 to 1.35 at point 5, but the interquartile ranges for all points were in the comparable range 0.9–1.4.
To quantify the significance of the differences, a fixed-effects one-way ANOVA was used. The factor was the grinding mode (k = 3 levels). The experimental unit was one milling series; the three repeated samples at five points were averaged within a series, yielding n = 10 independent series per mode (n = 30); the degrees of freedom are d f b e t w e e n = k − 1 = 2 , d f w i t h i n = N − k = 27 . The assumption check (normality of residuals according to Shapiro–Wilk, homogeneity of variances according to Levene’s test, p > 0.05) did not reveal any significant violations. For ⟨d⟩, the inter-mode differences are significant: F(2, 27) = 12.4, p < 0.001; for CV: F(2,27) = 9.8, p < 0.001.
Thus, the spatial heterogeneity of dust aerosol was mainly manifested in a change in the shape of the PSD and the relative proportion of fine fractions, while the integral parameters of the distributions were characterized by dominant inter-mode variability.

3.4. Comparison of Sieve Analysis and LALLS

The comparison of the PSDs obtained using sieve analysis and LALLS methods was performed on representative samples to assess the consistency of the experimental data and to identify methodological limitations of each method.
Figure 7a demonstrates the cumulative particle size distributions in a mass-based representation obtained by sieve analysis and laser diffraction for the same sample. Figure 7b shows the number-based distributions for the same sample.
Figure 7. Comparison of particle size distributions obtained by sieve analysis (blue lines) and LALLS laser diffraction (orange lines) for representative samples: (a)—mass-based CDF; (b)—number-based CDF.
In the mass-based representation, for particle sizes ranging from 50 to 1000 µm, the proximity of the medians of the distributions and the general slope of the curves obtained using the two methods was observed. The discrepancies between the methods for medium and large fractions did not exceed 5–7% and were within the experimental error characteristic of sieve analysis. This confirmed the applicability of sieve analysis for obtaining reliable mass distributions used in engineering calculations for dust collection and filtration systems.
In the number-based representation, the distributions obtained by the LALLS method were systematically shifted to a region of smaller equivalent sizes compared to the sieve analysis data. The most notable differences were observed for particles less than 50 µm in size, which was below the lower limit of resolution of the sieve analysis (26 µm). For fractions <26 µm that were not detected by the sieve method, LALLS detected up to 35% of all particles, depending on the milling mode. Analysis of the parameters of the number-based distributions (Table 3) revealed that the mean size values obtained by the LALLS method were systematically lower by 30–50%, while the coefficients of variation, skewness, and kurtosis were higher than for the corresponding distributions obtained by the sieve method. This quantitatively confirmed that LALLS revealed a more detailed structure of the finely dispersed part of the distribution.
Table 3. Comparison of statistical characteristics of the number-based distributions obtained by sieve analysis and LALLS methods (mean ± standard deviation for 10 representative samples).
Thus, both methods demonstrated consistency in the mass-based representation for medium and large fractions, while LALLS revealed a more detailed structure of the finely dispersed part of the distribution in the number-based representation.

3.5. Results of Parametric PSD Modeling

The approximation of calculated number-based PSDs derived from measured mass distributions was performed using two models: the Weibull distribution and the lognormal distribution.
The parameters of the Weibull distribution (shape parameter k and scale parameter λ) varied depending on the milling conditions. Shape parameter k ranged from 0.31 to 22.04, with most samples (87%), having values between 0.6 and 2.5. Scale parameter λ ranged from 0.7 to 145.3. The modes with air cooling were characterized by lower values of shape parameter k (mean values 1.2–1.9) compared with the modes without cooling (mean values 3.9–7.8). Scale parameter λ also showed a downward trend with cooling. The mean values were 36.9–41.2 for the cooling modes compared to 50.6–54.8 for the modes without cooling.
The parameters of the lognormal distribution (shape parameter σ and scale parameter μ) were also related to the milling conditions (Table 4). Shape parameter σ varied from 0.08 to 2.30, scale parameter μ (in exponential terms—the median of the distribution) ranged from 0.64 to 111.3. The modes with cooling were characterized by higher values of form parameter σ (mean values 0.97–1.12) compared to the modes without cooling (0.68–0.80). The median values of scale parameter μ were lower for the modes with cooling (27.9–31.5), compared to those without cooling (40.1–42.3).
Table 4. Statistical characteristics of the parameters of the model distributions for various milling conditions: mean ± standard deviation.
Both models showed good agreement with the experimental data for the given tasks (Table 5). However, there were some systematic differences in the accuracy of the descriptions of different distribution sites.
Table 5. Quality metrics of the calculated number-based PSD approximation for Weibull and lognormal distributions (mean ± standard deviation).
The mean RMSE values for the lognormal distribution were slightly lower (2.38 compared to 2.87), as were the average AIC values (–70.5 compared to –68.3), indicating some advantage of this model when averaging over the entire sample. The mean KS statistic values were 0.054 for the lognormal distribution and 0.063 for the Weibull distribution. For 64% of the samples, the lognormal distribution provided the best approximation according to the AIC, while for 36%, the Weibull distribution was better.
The analysis of the individual values of the quality metrics revealed a significant variability in the accuracy of the approximation depending on the milling conditions. The highest RMSE values (up to 7.65 for the Weibull distribution and up to 6.49 for the lognormal distribution) were observed for samples with a high content of large fractions.
For samples corresponding to modes without air cooling, the lognormal distribution provided the best approximation in 81% of cases. For modes with air cooling, the models were distributed more evenly, with 52% of samples better approximated by the lognormal distribution and 48% by the Weibull distribution. The Kolmogorov–Smirnov (KS) statistic for the Weibull distribution did not exceed 0.12 in 83% of samples, while the KS statistic for the lognormal distribution did not exceed the specified value in 89% of samples. Quantitative analysis of the approximation quality is shown at the figure Figure 8.
Figure 8. Comparison of the approximation quality of the Weibull and lognormal distributions: (a)—correlation of AIC values for the two models (dashed line is shown for clarity); (b)—distribution of samples according to the preferred approximation model.

4. Discussion

4.1. Nature of PSD Variability and Its Significance

The experimental data obtained demonstrated a high degree of variability in particle size distributions even within identical milling modes (Figure 3, Table 2). The envelope-region of cumulative curves, limited by the 10th and 90th percentiles, covered a significant area within the size range of 30–200 µm, indicating that there was no single “typical” PSD shape for the milling of grey cast iron.
The observed variation could not be explained solely by experimental error. It reflected the actual physical variability of the material fracture mechanism in the milling zone. The fragmentation process during the milling of brittle materials had a stochastic nature: local stress fluctuations, heterogeneity of the material structure (inclusions of graphite, grain boundaries), and the random nature of cracks and chips propagation led to the formation of different PSDs even under nominally identical milling conditions.
The greatest variability was observed precisely in the range of small and medium particle sizes (30–200 µm), while large fractions (>500–700 µm) showed a significantly lower spread. This indicated that the mechanism responsible for the formation of large particles (probably related to the geometry of the cutting tool and macroscopic chip removal) was more deterministic, whereas the formation of fine particles was sensitive to a variety of factors that were difficult to control.
For practical applications, it is impossible to use a single “average” distribution when designing aspiration systems or modeling aerosol transfer. Instead, a parametric approach is needed that takes into account both the technological conditions of the milling process and the probabilistic nature of dust formation.

4.2. Influence of Technological Parameters on PSD Formation

Under the studied production conditions, samples with air supply were characterized by an observed decrease in the average particle size (Figure 3), which may be due to the combined effect of various physical mechanisms. First, air flow may intensify heat removal and lower the contact temperature; for grey cast iron this could promote additional embrittlement and smaller fragments. Second, the airflow may selectively entrain already formed particles, enriching distant samples in fines. Because machines, tools and cutting parameters differed, these mechanisms are hypotheses and the air-cooling effect is not isolated.
Changes in CV, skewness and excess kurtosis during cooling (Table 2, Figure 3) indicated a qualitative change in PSD shape. The distributions became more “blurred” (CV growth) with a simultaneous increase in the fine tail (increased skewness) and the concentration of a significant proportion of particles in a relatively narrow size range (increased excess kurtosis). Such PSD transformation could not be described only by shifting the mean value and required an analysis of the higher moments of the distributions.
The observed positive correlation between the coefficient of variation and skewness (Figure 4) indicated that the expansion of the particle size spectrum was systematically accompanied by an increase in the fine tail. This meant that processes that led to greater polydispersity of dust (for example, increased crushing at high milling speeds or cooling) simultaneously generated additional amounts of fine particles, rather than simply “stretching” the distribution symmetrically in both directions. This fact was consistent with the concepts of brittle fracture mechanisms, where the formation of small fragments was a consequence of the secondary crushing of large fragments during their interaction.

4.3. Spatial Heterogeneity as a Result of Aerodynamic Classification

The revealed PSD differences depending on the sampling point (Figure 5 and Figure 6) indicated the presence of a natural aerodynamic classification of particles in the working area of the machine. The “machine tool—billet—air flow” system functioned as a distributed separator, where particles were separated based on their size under the influence of gravitational and inertial forces.
Larger particles with greater mass and inertia quickly deposited near the source of generation (point 1, directly at the milling cutter). In contrast, fine particles may remain suspended longer and be transported toward the operator’s breathing zone; this is consistent with the fine enrichment in settled-dust samples at points 4–5. These data do not quantify airborne concentrations (points 4–5). This explained the observed increase in the cumulative fraction of fine particles (less than 100 µm) at remote sampling points.
A fundamental result was the predominance of inter-mode variability over spatial variability: PSD differences caused by changing the milling mode or switching on cooling significantly exceeded the differences between the sampling points within the same mode. This meant that the primary distribution formed directly in the milling area was crucial for all subsequent aerosol behavior. Spatial redistribution only modified this primary PSD, mainly by removing large fractions, but did not generate new small particles and did not fundamentally change the shape of the distribution.
This conclusion was of great practical importance for CFD-DEM modeling. It was sufficient to use the PSD obtained near the source (point 1) as input data, and the spatial distribution could be modeled by setting the appropriate deposition rates for particles of different sizes.

4.4. Methodological Aspects: Sieve Analysis vs. Laser Diffraction

A comparison of the results of sieve analysis and laser diffraction (Figure 7) revealed systematic discrepancies due to fundamental differences in the physical principles of measurement. In the mass-based view, both methods demonstrated good qualitative agreement in the size range from 50 to 1000 µm, which confirmed the applicability of sieve analysis for engineering calculations where it was the mass characteristic of dust that was important (for example, when calculating the load on filters).
In the number-based representation, the discrepancies became significant: LALLS systematically shifted the distribution to a smaller-size area and registered a significant proportion of particles (up to 35%) in the range of less than 26 µm, which was impossible for sieve analysis. There were several reasons for this:
•
Difference in the physical principle of measurement. Sieve analysis defined size as the minimum geometric size that allowed a particle to pass through a sieve cell. LALLS measured the diffraction pattern and interpreted the result as an equivalent spherical diameter.
•
Influence of particle shape. The machine dust of grey cast iron had an angular, lamellar and fragmented shape, which was confirmed by microscopic studies. The assumption of sphericity, embedded in the LALLS algorithms, led to a systematic underestimation of the characteristic sizes for non-spherical particles.
•
Sensitivity to fine fractions. Laser diffraction had a significantly higher sensitivity to fine fractions, whereas sieve analysis in the small size range was limited by the mesh of sieves and material losses.
•
Effects of deagglomeration. When preparing samples for LALLS (liquid dispersion), particle agglomerates could be destroyed, which also led to a shift in distribution towards smaller sizes.
For practical applications, this meant that the choice of a method should be determined by a specific task. When designing aspiration systems and selecting dust collecting equipment, where mass loading was important, sieve analysis was sufficient. For CFD-DEM modeling of particle transport in air and assessment of respirable fractions (PM10, PM2.5, PM1), number-based distributions are fundamentally important, since it is the fine particles that determine the aerodynamic behavior of dust and its residence time in the air. In this study, number-based PSDs were obtained by converting mass-based distributions, and data on fractions below the limit of sieve analysis (<26 μm) are extrapolated from the model. Therefore, for the quantitative assessment of PM10, PM2.5, and PM1, it is recommended to use number-based distributions obtained using the laser diffraction (LALLS) method or more accurate methods, such as XCT. In further studies, it is planned to calibrate the extrapolated “tail” of the Weibull distribution by numerically comparing the PM10, PM2.5, and PM1 fractions predicted by the model with LALLS data, as well as with direct measurements of the concentrations of these fractions in the air of the work area.

4.5. Comparison of PSD Models and Selection for Practical Applications

Quantitative analysis of the approximation quality (Table 5, Figure 8) showed that the lognormal model demonstrated formally higher accuracy: the average RMSE values were lower (2.38 vs. 2.87), the AIC was lower (–70.5 vs. –68.3), and the KS statistics did not exceed the critical value for a larger number of samples (89% vs. 83%). These results were consistent with the literature data, where the lognormal distribution was often preferable for describing dispersed systems formed as a result of multiple fragmentation acts.
However, when choosing a model for practical engineering applications such as aspiration system design, occupational risk assessment, and CFD–DEM modeling, the extrapolation properties of models in the area of dimensions impossible to direct measurement (less than 26 µm) were of critical importance given that only settled dust is being considered, not all dust suspended in the air. Considering that only settled dust was collected, not all dust present in the air. The most hazardous fractions for health (PM10, PM2.5, and PM1) were in this range. The analysis of the extrapolation behavior of the models revealed a fundamental difference. The lognormal model predicts a decrease in the quantitative fraction of particles as their size decreases below a certain threshold.
The physical validity of the Weibull model for describing brittle fracture products was confirmed by numerous studies [28,29,30,31,32,33]. The mechanism of dust generation during the milling of grey cast iron included: brittle fracture with the formation of sharp fragments, abrasion and micro-cutting, secondary crushing of particles during their interaction. The Weibull model does not force the number fraction to vanish as size decreases: for k < 1 the density increases toward zero size, while for k > 1 it predicts a less sharp decrease than lognormal. This behaviour is not a universal monotonic increase.
Thus, despite the formally better global fit of the lognormal model over the measured range, Weibull is presented as a provisional conservative option for extrapolation below 26 µm and for CFD-DEM input. Weibull is not claimed as a validated preferred model.

4.6. Practical Engineering Applications

The applications below should be considered potential. They relate to settled dust collected under the studied conditions and require validation on suspended dust, and for PM fractions—direct measurements. We clearly distinguish between the experimentally confirmed results (parameterized PSD of settled dust, SCH20) and the proposed applications (CFD-DEM, equipment selection, risk assessment, respiratory protection), which have not been validated in this work.
The parameterized PSD models presented in Table 4 (especially the recommended Weibull model) can be directly used in engineering practice:
•
CFD-DEM modeling. When numerically modeling the aerodynamics of dust and air flows in the working area and designing ventilation systems, it is necessary to correctly set the input PSD as input data after checking for suspended dust. By using the Weibull model with parameters corresponding to a specific milling mode, we may enhance the realism of particle trajectories and assess the effectiveness of various aspiration schemes after validating the input PSD. Spatial aerodynamic sorting must be taken into account in the following cases: when PM fractions predominate; when the working area is large in extent; when ventilation is weak or unorganized.
•
Selection of dust collecting equipment. The efficiency of cyclones, fabric filters, and other cleaning devices significantly depends on the PSD of the captured dust. A model that predicts a significant proportion of small fractions, allows you to choose a device with the appropriate efficiency margin, or to provide multi-stage cleaning for mass load; direct measurements are required for PM fractions.
•
Occupational risk assessment. Predicting the share of respiratory fractions in the PSD of settled dust in the operator’s breathing area based on the Weibull model may provide a more conservative (cautious) risk assessment, which is consistent with the principles of preventive occupational safety.
•
Justification of the requirements for protective equipment. Particle PSD models can be one of the input parameters for establishing the requirements for the performance class of personal respiratory protective equipment after direct measurements of PM10/PM2.5/PM1 in the breathing zone; such measurements were not carried out in this study.
The model parameters, differentiated by milling modes and cooling availability, make it possible to take into account the actual technological conditions at a particular workplace. This improves the accuracy of engineering calculations and ensures the effectiveness of protective measures.

4.7. Research Limitations and Prospects

When interpreting the results, it was necessary to take into account some limitations.
The lower measurement limit for the sieve analysis was 26 µm, which prevented a direct assessment of the submicron fractions. Although the extrapolation of models to this area was physically justified, it required validation by laser diffraction or electron microscopy. Additionally, when converting mass distributions into quantitative ones, the assumption of a spherical particle shape and constant density was made. Real machine dust particles had a complex shape, which could introduce errors in the number-based distribution.
Furthermore, the study was conducted for one grade of gray cast iron (CH20). Other cast irons have different fracture toughness and microstructure, so extending the obtained models to other materials requires additional experimental studies, which could be a direction for future work. Sampling was carried out discretely, which does not allow assessing the dynamics of dust generation over time and possible fluctuations in PSD during the milling process.
Due to differences in machine tools, tools, and milling modes, the reduction in the average particle size should be considered an observed effect rather than an isolated causal factor. This is a limitation and sets the task for conducting a factorial experiment in the future. Let us note once again that the study selected settled dust, not all the dust that is generated. Therefore, the observed reduction in size may be due to the fact that the airflow selectively removes large particles, while the enriched fine fraction remains in the samples. Therefore, in this study, only the PSD of settled dust is considered, which clearly indicates a limitation and the need for further work.
The assertion that inter-mode variability exceeds spatial variability is based on a comparison of F-ratios in separate ANOVAs and is qualitative; a quantitative comparison of the variance components is a task for further work.
Statements regarding the applicability to ventilation design, impact assessment, and respiratory protection should be considered preliminary. The study did not determine the mass concentration of dust or the intensity of dust generation under various conditions; only the PSD of the settled dust was examined. The presence of individual anomalous samples is associated with local physical factors (tool chips, inclusions in the material, changes in cutting conditions) that were not controlled in this series.
Prospects for further research include:
•
CFD-DEM modeling of dust propagation in a working area using parameterized PSD as input data;
•
Development of an engineering methodology for designing dust control systems based on the predicted PSD of all the dust that is generated and suspended in the air;
•
Investigation of the influence of the geometry of the cutting tool and the structure of the processed material on the generation of large PSD fractions;
The implementation of these measures will make it possible to create a comprehensive system for predicting and managing dust levels at metalworking facilities, thereby reducing occupational risks and improving occupational safety.

5. Conclusions

As a result of the experimental and analytical study of the PSD of settled dust generated during the milling of grey cast iron, the following main conclusions can be formulated.
1. Experimental base and PSD variability. For the first time, a representative data sample on the dispersed composition of machine dust of grey cast iron SCH20 has been obtained and systematized, including 90 samples taken under three milling modes, with and without air cooling, at five spatial points within the working area. The results showed that the dust had a high degree of polydispersity: the average particle size varied from 16.6 to 227.7 µm, the coefficient of variation was from 0.55 to 2.53. The positive values of skewness (1.2–24.7) and kurtosis (>3) indicate an asymmetric shape and a right-skewed “tail” of the distribution. This variability, even within identical conditions, indicated the stochastic nature of the brittle fracture process and justified the need for a parametric approach to the description of PSD.
2. Influence of technological parameters. Under the studied production conditions, samples with air supply were characterized by an observed reduction in the average particle size (median values decreased from 70–120 µm to 50–70 µm) and a change in the shape of the distributions: the coefficients of variation, skewness and kurtosis increased. A weak positive correlation was found between the coefficients of variation and the skewness, indicating that the expansion of the size spectrum was accompanied by an increase in the fine tail of the distribution. Milling and cooling modes were found to have a dominant influence on the PSD compared to spatial redistribution of particles. The causal interpretation of the conclusion is limited by the current experimental design.
3. Spatial heterogeneity. It was found that as the distance from the milling zone increased (from point 1 near the milling cutter to point 5 in the operator’s breathing area), the median particle size decreased from 78 to 62 µm, and the coefficient of variation increased from 1.15 to 1.35. This indicated a natural aerodynamic classification of particles: large fractions were mainly deposited near the source, while settled-dust samples at locations corresponding to the operator’s breathing zone were enriched in fine particles; airborne concentrations were not measured. At the same time, in this dataset, between-mode differences in median d were larger than between-point differences (70–120 µm vs. 62–78 µm); no formal variance-component comparison was performed. This allows CFD-DEM modeling to use distributions obtained near the source as input data. The simplification is applicable to aspiration at the source and mass load, but it does not replace the consideration of spatial sorting when assessing exposure and PM fractions.
4. Comparison of analysis methods. Sieve analysis and LALLS results were compared. Both methods demonstrated good agreement within the range of 50–1000 µm in the mass representation (differences of 5–7%). This confirmed the applicability of sieve analysis for engineering calculations of aspiration systems. In the number-based representation, LALLS revealed a significantly higher content of fine particles. Up to 35% of the total particles were recorded for a fraction <26 µm, which was inaccessible to sieve analysis. Therefore, PSD models are sensitive to the estimated average size of the smallest fraction. The average particle size was 30–50% lower according to LALLS data, and the coefficients of variation, skewness, and kurtosis were higher compared to sieve analysis. These discrepancies were attributed to differences in physical principles of measurement, particle shape, and disaggregation effects.
5. Parametric modeling. The calculated number-based PSDs derived from measured mass distributions were approximated using Weibull and lognormal distributions. Model parameters were obtained for all modes and sampling points studied (Table 4). It was found that the modes with air cooling were characterized by lower values of Weibull shape parameter k (1.2–1.9 versus 3.9–7.8) and higher values of shape parameter of the lognormal distribution σ (0.97–1.12 versus 0.68–0.80). A comparison of quality metrics (RMSE, AIC, KS statistics) demonstrated that the lognormal model formally provided a slightly higher accuracy in approximating the experimental data (RMSE 2.38 versus 2.87, AIC –70.5 versus –68.3).
6. Selection of a model for practical applications. Despite the formal advantage of the lognormal model in terms of accuracy criteria within the measured range (>26 µm), the Weibull distribution can be considered a provisional conservative approximation for practical engineering tasks such as the design of aspiration systems, occupational risk assessment, and CFD-DEM modeling. Its use for designing aspiration systems, assessing occupational risk, and conducting CFD-DEM modeling requires validation using suspended dust and direct measurements of PM fractions. This choice is justified by the physical adequacy of the model to the mechanisms of brittle fracture (a less sharp decrease in the predicted number fraction toward smaller sizes and an increase in density for k < 1), which is consistent with the literature data and the results of laser diffraction, which record a significant particle content <26 µm.
7. Practical significance. The presented parameterized PSD models (Table 4) can be considered as input data after validation with suspended dust and PM measurements in the following areas:
- numerical modeling of aerodynamics in dust-air flows by CFD-DEM methods;
- designing and selecting dust collection equipment (cyclones, fabric filters);
- assessment of occupational risk and justification of requirements for personal respiratory protective equipment.
Differentiation of model parameters by milling modes and cooling allows taking into account the actual technological conditions at a particular workplace.
8. Limitations and prospects. The main limitations of this study include: the low limit of the sieve analysis measurement (26 µm), the assumption of spherical particle shape when converting mass distributions into quantitative ones, and the fact that the experiments were conducted on only one grade of grey cast iron (SCH20). Future research could include: validation of the obtained models using laser diffraction, electron microscopy (SEM), and XCT over the entire size range; CFD-DEM modeling of dust propagation with parameterized PSDs; investigation of dust generation during the processing of other structural materials; development of an engineering methodology for selecting aspiration system parameters based on the predicted dust PSD; accounting for microcracks and surface oxidation of particles in CFD-DEM modeling using the potentials of a reactive neural network (reactive NNP).

Author Contributions

Conceptualization, Y.I.B.; methodology, A.S.G.; software, A.S.G.; validation, A.S.G.; formal analysis, A.S.G.; investigation, D.A.D.; resources, B.C.M.; data curation, A.S.G.; writing—original draft preparation, D.A.D. and Y.I.B.; writing—review and editing, B.C.M., D.A.D. and Y.I.B.; visualization, D.A.D.; supervision, B.C.M. and Y.I.B.; project administration, B.C.M.; funding acquisition, B.C.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
AICAkaike information criterion
ANOVAAnalysis of variance
CFD-DEMComputing fluid dynamics—discrete element modeling
CVCoefficient of variation
ILOInternational Labour Organization
KSKolmogorov–Smirnov
LALLSLaser Angular Light Scattering Spectroscopy
PSDParticle size distribution
RMSERoot-mean-square error
WHOWorld Health Organization
XCTX-ray computer tomography

References

  1. Kondej, D.; Gawęda, E. Metals in Dust Fractions Emitted at Mechanical Workstations. Int. J. Occup. Saf. Ergon. 2012, 18, 453–460. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Khettabi, R.; Fatmi, L.; Masounave, J.; Songmene, V. On the micro and nanoparticle emission during machining of titanium and aluminum alloys. CIRP J. Manuf. Sci. Technol. 2013, 6, 175–180. [Google Scholar] [CrossRef] [Scilit]
  3. Kroisová, D.; Dvořáčková, Š.; Knap, A.; Knápek, T. Destruction of Carbon and Glass Fibers during Chip Machining of Composite Systems. Polymers 2023, 15, 2888. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Haddad, M.; Zitoune, R.; Eyma, F.; Castanie, B. Study of the surface defects and dust generated during trimming of CFRP: Influence of tool geometry, machining parameters and cutting speed range. Compos. Part A Appl. Sci. Manuf. 2014, 66, 142–154. [Google Scholar] [CrossRef] [Scilit]
  5. Dvořáčková, Š.; Kroisová, D.; Knápek, T.; Váňa, M. Effect of Cutting Conditions on the Size of Dust Particles Generated during Milling of Carbon Fibre-Reinforced Composite Materials. Polymers 2024, 16, 2559. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Andani, A.M.; Golbabaei, F.; Shahtaheri, S.J.; Foroushani, A.R. Evaluating Workers’ Exposure to Metalworking Fluids and Effective Factors in Their Dispersion in a Car Manufacturing Factory. Int. J. Occup. Saf. Ergon. 2014, 20, 273–280. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Iwasaki, M.; Hirai, K.; Fukumori, K.; Higashi, H.; Inomata, Y.; Seto, T. Characterization of Submicron Oil Mist Particles Generated by Metal Machining Processes. Aerosol Air Qual. Res. 2020, 20, 1469–1479. [Google Scholar] [CrossRef] [Scilit]
  8. Elsheikh, A.; Ali, A.B.M.; Saba, A.; Faqeha, H.; Alsaati, A.A.; Maghfuri, A.M.; Abd-Elaziem, W.; El Ashmawy, A.A.; Ma, N. A review on sustainable machining: Technological advancements, health and safety considerations, and related environmental impacts. Results Eng. 2024, 24, 103042. [Google Scholar] [CrossRef] [Scilit]
  9. Sultana, M.N.; Dhar, N.R.; Zaman, P.B. A Review on Different Cooling/Lubrication Techniques in Metal Cutting. Am. J. Mech. Appl. 2019, 7, 71. [Google Scholar] [CrossRef] [Scilit]
  10. World Health Organization; International Labour Organization. WHO/ILO Joint Estimates of the Work-Related Burden of Disease and Injury, 2000–2016: Global Monitoring Report; World Health Organization: Geneva, Switzerland, 2021; Available online: https://www.who.int/publications/i/item/9789240034945 (accessed on 14 June 2026).
  11. International Labour Organization. A Call for Safer and Healthier Working Environments; International Labour Organization: Geneva, Switzerland, 2023; Available online: https://researchrepository.ilo.org/esploro/outputs/report/A-call-for-safer-and-healthier/995343988202676 (accessed on 14 June 2026).
  12. Health and Safety Executive. Occupational Lung Disease Summary 2024; Health and Safety Executive: London, UK, 2024. Available online: https://www.hse.gov.uk/statistics/ (accessed on 14 June 2026).
  13. Health and Safety Executive. Work-Related Chronic Obstructive Pulmonary Disease (COPD) Statistics in Great Britain, 2024; Health and Safety Executive: London, UK, 2024. Available online: https://www.hse.gov.uk/statistics/ (accessed on 14 June 2026).
  14. Gong, X.; Xiao, X.; Zhao, J.; Liu, X.; Jiang, W.; Fan, Z. Influence of particle size on the separation performance and flotation kinetics of foundry dust. Process Saf. Environ. Prot. 2024, 183, 178–187. [Google Scholar] [CrossRef] [Scilit]
  15. Gharpure, A.; Heim, J.W., II; Vander Wal, R.L. Characterization and Hazard Identification of Respirable Cement and Concrete Dust from Construction Activities. Int. J. Environ. Res. Public Health 2021, 18, 10126. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Pan, L.; Golden, S.; Assemi, S.; Sime, M.F.; Wang, X.; Gao, Y.; Miller, J. Characterization of Particle Size and Composition of Respirable Coal Mine Dust. Minerals 2021, 11, 276. [Google Scholar] [CrossRef] [Scilit]
  17. Trechera, P.; Querol, X.; Lah, R.; Johnson, D.; Wrana, A.; Williamson, B.; Moreno, T. Chemistry and particle size distribution of respirable coal dust in underground mines in Central Eastern Europe. Int. J. Coal Sci. Technol. 2022, 9, 3. [Google Scholar] [CrossRef] [Scilit]
  18. Bocca, B.; Battistini, B.; Leso, V.; Fontana, L.; Caimi, S.; Fedele, M.; Iavicoli, I. Occupational Exposure to Metal Engineered Nanoparticles: A Human Biomonitoring Pilot Study Involving Italian Nanomaterial Workers. Toxics 2023, 11, 120. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Boac, J.M.; Maghirang, R.G.; Casada, M.E.; Wilson, J.D.; Jung, Y.S. Size Distribution and Rate of Dust Generated during Grain Elevator Handling. Appl. Eng. Agric. 2009, 25, 533–541. [Google Scholar] [CrossRef] [Scilit]
  20. Emadi Shaibani, M.; Ghambari, M. Characterization and comparison of gray cast iron powder produced by target jet milling and high energy ball milling of machining scraps. Powder Technol. 2011, 212, 278–283. [Google Scholar] [CrossRef] [Scilit]
  21. Fullenwider, B.; Kiani, P.; Schoenung, J.M.; Ma, K. Two-stage ball milling of recycled machining chips to create an alternative feedstock powder for metal additive manufacturing. Powder Technol. 2019, 342, 562–571. [Google Scholar] [CrossRef] [Scilit]
  22. Hengster, Y.; Lellep, M.; Weigel, J.; Bross, M.; Bosbach, J.; Schanz, D.; Schröder, A.; Huhn, F.; Novara, M.; Paz, D.G.; et al. Effects of anisotropy on the geometry of tracer particle trajectories in turbulent flows. Eur. J. Mech. B Fluids 2024, 103, 284–298. [Google Scholar] [CrossRef] [Scilit]
  23. Prasad, S.; Schweizer, C.; Bagaria, P.; Kulatilaka, W.D.; Mashuga, C.V. Effect of particle morphology on dust cloud dynamics. Powder Technol. 2021, 379, 89–95. [Google Scholar] [CrossRef] [Scilit]
  24. Garboczi, E.J.; Hrabe, N. Particle shape and size analysis for metal powders used for additive manufacturing: Technique description and application to two gas-atomized and plasma-atomized Ti64 powders. Addit. Manuf. 2020, 31, 100965. [Google Scholar] [CrossRef] [Scilit]
  25. Tan, L.; Ren, T. Coupled CFD-DEM modelling of mine dust dispersion in underground roadway. In Mining Goes Digital; CRC Press: London, UK, 2019; pp. 612–619. [Google Scholar] [CrossRef] [Scilit]
  26. Qian, J.; Wang, J.; Liu, H.; Xu, H. CFD Modeling of Ventilation and Dust Flow Behavior in Polishing and the Design of an Innovative Wet Dust Removal System. Int. J. Environ. Res. Public Health 2020, 17, 6006. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Azimova, N.N.; Ladosha, E.N.; Kholodova, S.N.; Tsymbalov, D.S.; Yatsenko, O.V. Statistical analysis of sizing features of dust generated under the mechanical metal-working. Vestn. Don State Tech. Univ. 2020, 20, 68–78. [Google Scholar] [CrossRef] [Scilit]
  28. Zhang, G.; Fan, Y.; Yang, R.; Li, S. Application of the Rosin-Rammler function to describe quartz sandstone particle size distribution produced by high-pressure gas rapid unloading at different infiltration pressure. Powder Technol. 2022, 412, 117982. [Google Scholar] [CrossRef] [Scilit]
  29. Guo, W.; Han, Y.; Gao, P.; Tang, Z. Effect of operating conditions on the particle size distribution and specific energy input of fine grinding in a stirred mill: Modeling cumulative undersize distribution. Miner. Eng. 2022, 176, 107347. [Google Scholar] [CrossRef] [Scilit]
  30. Fowler, A.C.; Scheu, B. A theoretical explanation of grain size distributions in explosive rock fragmentation. Proc. R. Soc. A Math. Phys. Eng. Sci. 2016, 472, 20150843. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Abousrafa, A.; Olewski, T.; Véchot, L. Use of a two-parameter Weibull distribution for the description of the particle size effect on dust minimum explosible concentration. J. Loss Prev. Process Ind. 2024, 88, 105269. [Google Scholar] [CrossRef] [Scilit]
  32. Stoyan, D.; Zhang, Z.-X. A stochastic model leading to various particle mass distributions including the RRSB distribution. Granul. Matter 2023, 25, 67. [Google Scholar] [CrossRef] [Scilit]
  33. Colorado-Arango, L.; Menéndez-Aguado, J.M.; Osorio-Correa, A. Particle Size Distribution Models for Metallurgical Coke Grinding Products. Metals 2021, 11, 1288. [Google Scholar] [CrossRef] [Scilit]
  34. Shi, Y.; Liu, W.; Dong, Y.; Zhao, X.; Xiang, Y.; Zhang, T.; Lv, L. Atmospheric aerosol particle size distribution from Lidar data based on the lognormal distribution mode. Heliyon 2022, 8, e09975. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Bao, W.; Zhu, S.; Guo, S.; Wang, L.; Huang, S.; Fu, J.; Ye, Z. Particle size distribution mathematical models and properties of suspended solids in a typical freshwater pond. Environ. Pollut. 2018, 241, 164–171. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Gao, P.; Zhang, T.S.; Wei, J.X.; Yu, Q.J. Evaluation of RRSB distribution and lognormal distribution for describing the particle size distribution of graded cementitious materials. Powder Technol. 2018, 331, 137–145. [Google Scholar] [CrossRef] [Scilit]
  37. Sinkhonde, D. Particle size distribution-based models for predicting particle sizes of ground clay bricks: Theories that account for changes in milling times. Clean. Waste Syst. 2023, 5, 100099. [Google Scholar] [CrossRef] [Scilit]
  38. Ord, A.; Blenkinsop, T.; Hobbs, B. Fragment size distributions in brittle deformed rocks. J. Struct. Geol. 2022, 154, 104496. [Google Scholar] [CrossRef] [Scilit]
  39. Sanchidrián, J.A.; Ouchterlony, F.; Segarra, P.; Moser, P. Size distribution functions for rock fragments. Int. J. Rock Mech. Min. Sci. 2014, 71, 381–394. [Google Scholar] [CrossRef] [Scilit]
  40. Grimani, A.; Bergström, G.; Casallas, M.I.R.; Aboagye, E.; Jensen, I.; Lohela-Karlsson, M. Economic Evaluation of Occupational Safety and Health Interventions From the Employer Perspective. J. Occup. Environ. Med. 2018, 60, 147–166. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  41. Krawczykowski, D. Unification of particle size analysis results, part 1—Comparison of particle size distribution functions obtained by various measurement methods. Measurement 2024, 238, 115403. [Google Scholar] [CrossRef] [Scilit]
  42. ISO 3310-1:2016; Test Sieves—Technical Requirements and Testing—Part 1: Test Sieves of Metal Wire Cloth. International Organization for Standardization (ISO): Geneva, Switzerland, 2016. Available online: https://www.iso.org/standard/62410.html (accessed on 14 June 2026).
  43. DIN 66165; Particle Size Analysis—Sieving Analysis. Deutsches Institut für Normung: Berlin, Germany; Beuth Verlag: Berlin, Germany, 2016. [Google Scholar] [CrossRef] [Scilit]
  44. Matsuyama, T. Parametric and non-parametric evaluation of conversion of number-based particle size distribution to mass-based distribution. Adv. Powder Technol. 2024, 35, 104594. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.