Systematic Evaluation of Brayton Battery Concepts for Multi-Purpose Energy Applications

Institute of Engineering Thermodynamics, German Aerospace Centre (DLR), 70569 Stuttgart, Germany
Appl. Sci.2026, 16(23), 11735;https://doi.org/10.3390/app162311735 
(registering DOI)

Abstract

Brayton batteries, a class of Carnot batteries based on the Joule–Brayton cycle, can provide electricity, heat, and cooling from a single storage system. This study re-evaluates a systematic structural analysis of more than 200,000 Brayton battery configurations, simulated in Ebsilon Professional®, using the coefficient of performance (COP) instead of the previously applied round-trip utilization as the key performance indicator. Applications considered are electricity-only generation and coupled generation of electricity with heat, cooling, or both, each with and without waste heat integration, at compressor outlet temperatures of 450 °C and 625 °C. For electricity-only applications, round-trip efficiencies range from 20% to 50%, with higher values at 625 °C. Coupled generation raises the COP—up to 88% for electricity and heat, and above 100% with waste heat integration—at the expense of electrical efficiency. No feasible solutions were found for the simultaneous generation of electricity, heat, and cooling within the analyzed parameter space. The identified lead configurations predominantly use air as the working fluid at relatively low pressures (<13 bar), with or without a recuperator in the charging line, and with heat exchange at different process stages. They will be investigated further using dynamic simulation, with a focus on thermal energy storage.

1. Introduction

The ongoing energy transition is driving the replacement of conventional thermal power plants with innovative energy storage solutions that enhance the efficient utilization of renewable energy sources. A promising technology in this domain is the Carnot battery, also known as Pumped Thermal Electricity Storage (PTES) or Pumped Heat Storage (PHES). These systems convert electrical energy into thermal energy, which is stored in cost-effective materials like molten salts or solid media. When required, the stored thermal energy is converted back into electricity.
The Brayton battery, a specific type of Carnot battery, operates based on the Joule–Brayton cycle with gaseous working fluids. This system comprises a compressor, turbine, and two thermal storage units operating at different temperature levels. During the charging phase, electrical energy powers the compressor, raising the temperature of the working fluid, which then transfers heat to the high-temperature thermal energy storage (HT-TES). The discharging phase reverses this process: the turbine generates electricity by extracting heat from the stored thermal energy.
Krüger [1] presented a comprehensive analysis of various Brayton battery concepts for combined power, heating, and cooling applications. A systematic structural analysis examined over 200,000 configurations, evaluating the efficiency and performance of different system designs. The study identified key configurations optimized for specific applications based on a key performance indicator (KPI), namely the round-trip utilization (RTU). However, due to its mathematical definition, RTU can introduce singularities, making it less suitable for all scenarios. To address this limitation, this study reevaluates the calculations from Krüger [1] using the coefficient of performance (COP) as an alternative KPI. The newly identified optimal configurations are currently being investigated through dynamic system simulations.
The state of the art and research developments on Brayton batteries were extensively covered by Krüger [1]. Therefore, only a brief summary is provided here, supplemented with recent publications.
Brayton batteries constitute a rapidly advancing research field, with increasing attention devoted to improving system efficiency, operational flexibility, and economic feasibility. Compared with electrochemical energy storage technologies such as lithium-ion batteries, Brayton battery concepts exhibit several inherent advantages. In particular, they are well suited for medium- to large-scale energy storage applications and enable multifunctional energy use by providing not only electrical power but also thermal energy for heating and cooling purposes. Moreover, their reliance on durable and widely available materials contributes to long service lifetimes and potentially lower long-term material costs.
Despite these benefits, significant technical and economic challenges remain. One of the primary limitations is the relatively low round-trip efficiency, which typically ranges between 20% and 50%, depending on the specific system configuration [2,3]. In addition, the design and operation of Brayton batteries require sophisticated thermal management strategies. Efficient integration of heat exchangers and waste heat recovery is essential to enhance overall system performance [2,4].
To address these challenges, several optimization strategies are currently under investigation. Recent studies increasingly focus on extending the functional scope of Brayton batteries beyond pure electricity generation toward the combined production of electricity, heat, and cooling [5,6]. Furthermore, alternative working fluids—such as air, carbon dioxide, or argon—are being explored to improve energy conversion efficiency and system performance [7,8]. The systematic utilization of waste heat represents another promising pathway to increase overall efficiency [6,7].
While thermodynamic analyses remain a central component of current research [9,10], economic considerations are gaining increasing importance. Capital cost optimization studies [11,12], as well as comprehensive techno-economic assessments [5,13], contribute to evaluating and improving the competitiveness of Brayton battery systems.
Particular attention has recently been directed toward CO2-based Brayton cycles, which are considered a promising approach for energy storage applications [14,15]. Their integration with renewable energy sources—especially solar thermal power plants—has been identified as a key opportunity to further expand their application potential [16,17].
Future research is expected to focus on novel materials and advanced system designs [18,19], as well as hybrid energy storage concepts that combine Brayton batteries with other storage technologies [20,21]. In addition, innovative concepts linking Brayton battery systems with chemical processes, such as hydrogen production or CO2 utilization, are increasingly being explored [14,22].
Despite the substantial progress achieved to date, further technological development is required for Brayton batteries to become commercially competitive with established energy storage technologies. Continued research efforts must therefore address both technical feasibility and economic viability to fully exploit the potential of this promising energy storage concept. As previously noted by Krüger [1], no publications directly comparable to the systematic structural analysis approach adopted in the present study have been identified, and this assessment remains valid.
Compared with [1], the present study makes four contributions. First, the RTU, whose denominator can approach zero for configurations with large thermal outputs during charging, is replaced by the COP, which is substantiated by its analogy to the total efficiency ratio of polyvalent heat pumps and to the overall efficiency of cogeneration plants. Second, the COP is decomposed into electrical, heating, and cooling shares, so that configurations with equal COP but different supply characteristics can be distinguished. Third, the complete set of feasible concepts from the systematic structural analysis is re-evaluated on this basis, and lead concepts for the coupled generation of electricity with heat or cooling, with and without waste heat integration, are identified and characterized. Fourth, the underlying physical mechanisms are discussed, and design-relevant conclusions are derived with regard to the working fluid, recuperation, compressor outlet temperature, and the position of heat extraction. In addition, the COP-based assessment is compared with the RTU-based assessment of [1], and a simplified exergetic efficiency is evaluated as a complementary indicator.

2. Methods

The methodological approach is based on the systematic concept analysis of Brayton batteries described in Krüger [1]. The simulations were carried out with Ebsilon Professional®, analyzing a large number of configurations for feasibility and efficiency. The main assumptions and boundary conditions follow those of the previous study and are briefly summarized below. This study examines the following coupled generation applications:
  • Coupled generation of electricity and heat, CHP;
  • Coupled generation of electricity and heat with waste heat integration, CHP+WHI;
  • Coupled generation of electricity and cooling, CCP;
  • Coupled generation of electricity and cooling with waste heat integration, CCP+WHI;
  • Coupled generation of electricity, heat, and cooling, CCHP.

2.1. Modelling Assumptions and Simulation Approach

The following key assumptions were made to evaluate the systems:
  • Ideal gas behaviour of the working media;
  • Neglect of pressure and heat losses;
  • Isentropic efficiency of the turbomachinery of 0.9;
  • Mechanical and electrical efficiencies according to the state of the art (see Table 1);
  • Ambient conditions: 15 °C ambient temperature.
Table 1. Boundary conditions and fixed simulation parameters (according to [1]).
Two different compressor outlet temperatures (COTs) were analysed: 450 °C (current state of the art) and 625 °C (potential further development). The system concepts were analysed with regard to different working media (air, CO2, argon) and the integration of recuperators.

2.2. Efficiency Assessment

For systems that supply electricity only, the energy efficiency is expressed by the round-trip efficiency (RTE):
RTE = W Turb , d − W Comp , d W Comp , c − W Turb , c
W stands for work. The indices Turb and Comp stand for turbine and compressor, respectively, and c and d for charging and discharging, respectively.
For coupled generation, the RTE is a necessary but not a sufficient indicator, since the useful heating and cooling supplied are not included in the balance. In the previous study [1], the round-trip utilization (RTU) was therefore introduced, which strictly separates the charging and discharging phases:
RTU = W Turb , d − W Comp , d + Q H , d + Q C , d W Comp , c − W Turb , c − Q H , c − Q C , c
Q denotes heat; the indices H and C refer to the useful heat and the useful cooling supplied to consumers. In the denominator, the heating and cooling supplied during charging are subtracted from the net electrical input. For configurations that supply large thermal outputs while charging, the denominator can approach zero, and the RTU then becomes unbounded. The RTU is therefore not used in this study.
Instead, the coefficient of performance (COP) is adopted as the central indicator. It relates all useful outputs—the net electricity supplied during discharging and the useful heating and cooling supplied during both charging and discharging—to the net electrical input during charging:
COP = W Turb , d − W Comp , d + Q H , d + Q C , d + Q H , c + Q C , c W Comp , c − W Turb , c
The COP thus follows the definition of an efficiency as the ratio of benefit to expenditure rather than that of a storage parameter, i.e., the ratio of benefit during discharging to expenditure during charging. This is appropriate because the systems investigated can supply heat or cold in both operating phases. Comparable COP definitions have been applied to Carnot battery-based multi-energy systems by Zhao et al. [4] and Huang et al. [6].
Adding heating and cooling outputs that originate from the same thermodynamic cycle is established practice for heat pumps operating in simultaneous heating and cooling mode. Eurovent rates such polyvalent units by the total efficiency ratio (TER), defined as the sum of heating and cooling capacity divided by the total electrical power input; its seasonal counterpart, the STER, likewise adds the annual heating and cooling demands without weighting them by energy quality [23]. Byrne and Ghoubali [24] use the same summation for the COP of heat pumps in simultaneous operation and apply an exergetic efficiency only as a complementary measure. Similarly, the overall efficiency of cogeneration plants is defined as the annual sum of electricity and useful heat output divided by the fuel input, where useful heat explicitly includes heat produced to satisfy a demand for cooling [25]. In coupled operation, a Brayton battery is thermodynamically analogous to a polyvalent heat pump: the hot and cold streams are produced in the same cycle, but each constitutes a separate useful service delivered to a separate consumer. Consequently, no energy flow is counted twice.
Since the same COP can result from very different combinations of services, the COP is additionally decomposed into partial indicators with a common denominator:
COP = COP el + COP H + COP C
with
COP el = W Turb , d − W Comp , d W Comp , c − W Turb , c = RTE
COP H = Q H , c + Q H , d W Comp , c − W Turb , c
COP C = Q C , c + Q C , d W Comp , c − W Turb , c
Here, QH and QC denote the useful heating and the useful cooling supplied to consumers during charging (c) and discharging (d). The electrical share COPel is identical to the RTE in Equation (1). In each of the applications evaluated in Section 3, only one thermal service is provided—heating in CHP and cooling in CCP—while no feasible solutions exist for the simultaneous generation of electricity, heat, and cooling (Section 3.4). Consequently, the thermal share follows directly as COPH = COP − RTE or COPC = COP − RTE, and heating and cooling contributions are not added in any of the results presented. The decomposition for the lead concepts is summarized in Section 3.5.
Only useful heat flows that cross the system boundary to a consumer are included in the balance; this applies to heat supplied during both charging and discharging. Waste heat and ambient heat used as heat sources are not included in the denominator, in the same way as the source heat is not included in the COP of a conventional heat pump. COP values above unity are therefore possible for configurations with waste heat integration and do not violate energy conservation. Useful heat is supplied at 250 °C and cooling at 6 °C (see Table 1). As with the TER, COP values are only comparable at the same temperature levels.
The COP weights electricity, heating, and cooling equally, which is common practice in the evaluation of cogeneration systems, but it does not reflect differences in energy quality or economic value. An exergetic evaluation would rate the cooling, which is supplied close to ambient temperature, very low compared with its practical and economic value, whereas an indicator based on primary energy savings depends strongly on the choice of the reference systems. Both alternatives may lead to a different ranking of configurations. Therefore, the COP is retained as the primary indicator, and a simplified exergetic efficiency is evaluated for the lead concepts as a complementary indicator.
To account for the different energy qualities, the exergetic efficiency ψ relates the exergy of the useful outputs to the exergy input:
ψ = W Turb , d − W Comp , d + θ H Q H , c + Q H , d + θ C Q C , c + Q C , d W Comp , c − W Turb , c + θ WH Q WH
where θH = 1 − T0/TH and θC = T0/TC − 1 denote the Carnot factors of the useful heat and the useful cooling, and θWH = 1 − T0/TWH that of the externally supplied waste heat QWH. As a simplification, the thermal flows are assumed to be transferred at the constant supply temperatures TH = 250 °C, TC = 6 °C, and TWH = 90 °C, with an ambient temperature of T0 = 15 °C (Table 1), which yields θH = 0.449, θC = 0.032, and θWH = 0.207. For configurations with waste heat integration, the COP related to the total energy input, including the waste heat,
COP tot = COP 1 + Q WH W Comp , c − W Turb , c
additionally separates the contribution of the externally supplied waste heat from the performance attributable to the storage system. Both indicators are evaluated for the lead concepts in Section 3.5.

2.3. Variants and Analysis

The procedure for generating and simulating the concepts is identical to that described in Section 2.2 of [1] and is summarized here. All concepts are derived from a single universal Brayton battery model in Ebsilon Professional® (version 16). It comprises the mandatory turbomachinery and the two thermal energy storages of the base flow sheet, supplemented by optional heaters and coolers at each position between the main components, which are switched on or off via value inputs. A controller adjusts the compressor outlet pressure such that the specified COT is reached in the charging line.
The variants differ in the cycle type (closed or open), the working fluid (air, CO2, or argon, with open cycles operated with air only), the recuperator arrangement (for air: none, charging line only, or charging and discharging lines), the COT (450 °C or 625 °C), the application including waste heat integration, and the number and position of the activated heaters and coolers (combination patterns 1C∨1H, 2C∨2H, 1C∧1H, 1C∧2H, 2C∧1H, and 2C∧2H, where the numbers give the number of coolers C and heaters H, and ∨ and ∧ denote alternative and simultaneous use, respectively; e.g., 2C∧2H stands for two coolers and two heaters). Enumerating all combinations results in 202,814 distinct concepts. They were calculated automatically using the time-series function of Ebsilon Professional®, in which each row of the time series defines a different combination of activated heaters and coolers. All combinations were calculated, including those that are not physically operable, in order to identify the feasible concepts. Of the 202,814 concepts, 1132 (less than 1%) proved to be physically feasible under the fixed parameter set. A concept was classified as feasible if Ebsilon Professional® completed the calculation without errors and all resulting temperatures were physically meaningful. Ebsilon Professional® solves the mass and energy balances of all components simultaneously, and a result is only accepted if the solver converges according to its default convergence criteria. A breakdown of the infeasible concepts by cause is not available, since the time-series calculations only distinguish between successful and failed calculations; typical causes are heater or cooler positions at which the required supply temperatures cannot be reached and temperature crossings in heat exchangers. Only the feasible concepts are evaluated in Section 3; concepts with high compressor pressure ratios were retained and are shown in the full-range diagrams. The boundary conditions and fixed parameters are summarized in Table 1.
In the stationary simulation, the charging and discharging processes are calculated simultaneously with equal mass flow rates, which corresponds to equal charging and discharging durations. The thermal energy storages are modelled as heat exchangers between the charging and the discharging flow with a storage efficiency of 0.95 (Table 1), which accounts for their thermal losses; their operating temperature ranges result from the respective cycle states. Hence, apart from these losses, the heat charged into the HT-TES and the LT-TES equals the heat discharged, i.e., the energy balances of the storages are closed over one cycle by construction. All energy flows in Equations (1)–(9) therefore refer to the same mass flow and period, and RTE and COP describe a cyclically consistent operation. The storage capacity scales with the operating duration and does not affect these stationary indicators.
The results were checked for plausibility in two ways. First, energy conservation is satisfied: the COP of all feasible concepts without waste heat integration remains below 100% (maximum 87.6%), and for the lead concepts with waste heat integration, the COP related to the total energy input including waste heat lies between 82.8% and 89.9% (Section 3.5). Second, the RTE of the concepts for pure electricity generation (20–50%, maximum 50.6%) lies within the range reported for Brayton batteries in the literature [2,3]. A validation against experimental data is not possible, as none of the analysed configurations has been built (Section 4).

3. Results

3.1. Power Generation With or Without Waste Heat Integration

The results for pure power generation systems can be found in Krüger [1]. The values for round-trip efficiency (RTE) range between 20% and 50%. Concepts operating at a compressor outlet temperature (COT) of 450 °C exhibit lower RTE values compared to those operating at 625 °C. No clear trend is observed regarding the choice of working fluids, nor does the inclusion or exclusion of recuperators show a significant impact. The integration of additional waste heat does not lead to significantly higher efficiency values.

3.2. Coupled Generation of Electricity and Heat With or Without Waste Heat Integration

In Figure 1, the coefficient of performance (COP) is compared with the round-trip efficiency (RTE) to assess the simultaneous production of electricity and heat without incorporating waste heat recovery. Each point represents a viable system configuration. Colour and marker shape identify the working fluid and the recuperator arrangement (air with a recuperator in the charge cycle, air with an additional recuperator in the discharge cycle, air without a recuperator, air in an open cycle, CO2, and argon), while open markers denote a COT of 450 °C and filled markers a COT of 625 °C. The solid line marks COP = RTE, and the dashed lines indicate constant heating shares COPH = COP − RTE according to Equation (6); the vertical distance of a point from the solid line therefore directly gives its heating share. The lead concepts are labelled in all figures.
Figure 1. Coupled generation of electricity and heat without waste heat integration: COP over RTE.
Values for COP reach up to 88%, though this comes at the cost of RTE, which remains consistently below 25%. For open-cycle configurations, only a small number of physically viable concepts exist, and these exhibit particularly low values for both COP and RTE. No clear trends emerge regarding the choice of working fluids in closed systems. However, the integration of a recuperator in the charge cycle enables configurations with a COT of 450 °C, whereas systems lacking a recuperator require higher compressor outlet temperatures to be feasible.
The following figures illustrate how COP varies with the compressor’s pressure ratio (Π) during the charging cycle: Figure 2 provides an overview of the entire pressure ratio range, while Figure 3 focuses on values between 1 and 10.
Figure 2. Coupled generation of electricity and heat without waste heat integration: COP over Π for the entire pressure ratio range.
Figure 3. Coupled generation of electricity and heat without waste heat integration: COP over Π for pressure ratios between 1 and 10.
Most system designs exhibit pressure ratios up to 10 or slightly higher, with the exception of open-cycle configurations, which require significantly elevated pressures. As previously noted, these open concepts achieve only modest COP values. Among closed-cycle configurations, it is evident that argon as a working fluid allows for lower pressure ratios.
For the selection of representative concepts in the combined generation of electricity and heat without waste heat integration, designs with the highest COP at COT = 450 °C and COT = 625 °C were chosen, prioritizing simplicity where possible. In cases where multiple concepts exhibited similar COP values, the least complex system was preferred. The selected lead concepts are illustrated in Figure 1 and Figure 2:
  • CHP1: Utilizes air as the working fluid. Heat extraction occurs after the compressor in the charge line. A recuperator is incorporated into the charge cycle. COT = 450 °C; COP = 87.6%; RTE = 13.1%; Π = 10.6. Flow scheme: Figure 4.
  • CHP2: Also employs air as the working fluid, with process heat extracted downstream of the compressor in the discharge line. COT = 625 °C; COP = 81.2%; RTE = 19.0%; Π = 2.0. Flow scheme: Figure 5.
Figure 4. Lead concept CHP1 for coupled generation of electricity and heat without waste heat integration.
Figure 5. Lead concept CHP2 for coupled generation of electricity and heat without waste heat integration.
Figure 6, Figure 7 and Figure 8 illustrate the performance of system designs incorporating additional waste heat integration, using the same marker scheme as Figure 1, Figure 2 and Figure 3. Square markers indicate configurations that include a recuperator in both the charge and discharge cycles, highlighting the impact of recuperation on overall system efficiency.
Figure 6. Coupled generation of electricity and heat with waste heat integration: COP over RTE.
Figure 7. Coupled generation of electricity and heat with waste heat integration: COP over Π for the entire pressure ratio range.
Figure 8. Coupled generation of electricity and heat with waste heat integration: COP over Π for pressure ratios between 1 and 10.
The inclusion of waste heat recovery significantly enhances the COP, with some configurations achieving values approaching or even exceeding 100%. To identify the most effective setups for combined electricity and heat generation with waste heat integration, the following key concepts were selected, as illustrated in Figure 6:
  • CHP+WHI1: Utilizes air as the working fluid. Heat is extracted before the turbine in the discharge cycle, while waste heat is integrated before the turbine in the charge cycle. A recuperator is implemented in the charge line. COT = 625 °C; COP = 103.1%; RTE = 0.9%; Π = 12.3. Flow scheme: Figure 9.
  • CHP+WHI2: Uses air as the working fluid. Heat extraction takes place after the compressor in the charge cycle, and waste heat is integrated following the low-temperature thermal energy storage (LT-TES). A recuperator is present in the charge line. COT = 450 °C; COP = 98.5%; RTE = 1.4%; Π = 6.6. Flow scheme: Figure 10.
  • CHP+WHI3: Air is the working fluid. Heat extraction occurs at two points: after the high-temperature thermal energy storage (HT-TES) in the charge cycle and after the turbine in the discharge cycle. Waste heat is recovered post-turbine in the charge line. The charge cycle includes a recuperator. COT = 625 °C; COP = 88.8%; RTE = 16.4%; Π = 6.1. Flow scheme: Figure 11.
Figure 9. Lead concept CHP+WHI1 for coupled generation of electricity and heat with waste heat integration.
Figure 10. Lead concept CHP+WHI2 for coupled generation of electricity and heat with waste heat integration.
Figure 11. Lead concept CHP+WHI3 for coupled generation of electricity and heat with waste heat integration.
These three configurations were selected because CHP+WHI1 and CHP+WHI2 achieve particularly high COP values, although their RTE remains low. CHP+WHI3, in contrast, offers a more balanced performance with a relatively high COP and a notable RTE. However, the increased complexity of this system—due to multiple heat extraction points—along with small temperature gradients at the recuperator, may introduce challenges in quasi-stationary system simulations.

3.3. Coupled Generation of Electricity and Cooling With or Without Waste Heat Integration

In Figure 12, the coefficient of performance (COP) is plotted against the round-trip efficiency (RTE) for various feasible configurations of electricity and cooling generation without waste heat integration. Each data point represents a physically viable system design. The marker scheme corresponds to that of Figure 1; here, the dashed lines indicate constant cooling shares, COPC = COP − RTE, according to Equation (7).
Figure 12. Coupled generation of electricity and cooling without waste heat integration: COP over RTE.
The calculated COP values range from 27% to 63%, which are lower than those observed for the combined generation of electricity and heat. However, the RTE reaches up to 45%, representing a significant increase in efficiency within this application. A dominant share of the feasible configurations includes a recuperator in the charging line, and many utilize Argon as the working fluid. Nonetheless, a limited number of viable concepts operate with air and without a recuperator. Notably, designs incorporating two recuperators exhibit markedly lower performance compared to the other configurations.
The following figures illustrate the relationship between COP and the compressor pressure ratio (Π) in the charging cycle: Figure 13 presents the full range of compressor pressure ratios, while Figure 14 focuses on a restricted range from 1 to 10.
Figure 13. Coupled generation of electricity and cooling without waste heat integration: COP over Π for the full range of compressor pressure ratios.
Figure 14. Coupled generation of electricity and cooling without waste heat integration: COP over Π for pressure ratios between 1 and 10.
A closer examination reveals that the previously mentioned dominance is only apparent, as many markers were directly overlapping. In reality, there are approximately as many feasible solutions utilizing air as the working fluid, even without a recuperator. Additionally, while concepts incorporating a recuperator tend to exhibit higher compressor pressure ratios, they do not necessarily achieve better efficiencies.
For future in-depth studies, the lead concepts for the coupled generation of power and cooling without heat integration are selected based on their compressor outlet temperatures (COT) of 450 °C and 625 °C. These configurations represent the best trade-off between high COP and high RTE while maintaining a simple system design. When multiple concepts achieve comparable COP and RTE values, the structurally simpler system is preferred, as illustrated in Figure 13 and Figure 14:
  • CCP1: Working fluid: Air. A cooler is placed before the turbine in the charge path, with cooling provision occurring after the turbine in the charge path. Additionally, a cooler is positioned before the compressor in the discharge path. COT = 625 °C; COP = 62.6%; RTE = 42.4%; Π = 2.8. Flow scheme: Figure 15.
  • CCP2: Identical to CCP1 but with a maximum temperature of 450 °C, yielding the following performance metrics: COP = 60.1%; RTE = 35.5%; Π = 2.5. Flow scheme: Figure 16.
Figure 15. Lead concept CCP1 for coupled generation of electricity and cooling without waste heat integration.
Figure 16. Lead concept CCP2 for coupled generation of electricity and cooling without waste heat integration.
In Figure 17 and Figure 18, the outcomes for concepts involving the combined generation of electricity and cooling under the assumption of waste heat integration are illustrated.
Figure 17. Coupled generation of electricity and cooling with waste heat integration: COP over RTE.
Figure 18. Coupled generation of electricity and cooling with waste heat integration: COP over Π.
The additional integration of waste heat results in a greater number of physically feasible solutions compared to scenarios without heat input. However, it becomes evident that this does not lead to significant improvements in COP and RTE values. Consequently, a detailed discussion of these results is not warranted. As a result, no concepts incorporating waste heat integration will be considered for future in-depth investigations into the coupled generation of electricity and cooling.

3.4. Coupled Generation of Electricity, Heat, and Cooling

Under the defined conditions, no physically feasible solutions exist for the simultaneous coupled generation of electricity, heat, and cooling. However, potential solutions could arise by deviating from the predefined temperature levels for heat or cooling provision or by allowing different or variable compressor outlet temperatures. Since this was beyond the scope of the present study, such scenarios were not further investigated. The main constraint is that the analysed concepts would have to provide heat above approximately 260 °C and cooling below approximately −4 °C (including the temperature difference of 10 K) within one cycle with a fixed COT. Extracting process heat lowers the temperature level in the hot part of the cycle, whereas cooling requires a sufficiently low temperature after expansion; with the fixed COT, no combination of heater and cooler positions satisfied both requirements simultaneously.

3.5. Overview of the Lead Concepts

Table 2 summarizes the lead concepts selected in Section 3.2 and Section 3.3, and Figure 19 shows the decomposition of their COP into the electrical, heating, and cooling shares according to Equations (4)–(7). In the concepts for the coupled generation of electricity and heat, the COP is dominated by the heating share: the electrical share ranges from below 2% for CHP+WHI1 and CHP+WHI2 to 19% for CHP2. In contrast, electricity accounts for the larger part of the COP in both CCP concepts, with 68% for CCP1 and 59% for CCP2. Concepts with similar COP can therefore have very different supply characteristics. For example, CHP+WHI2 and CHP+WHI3 achieve COP values of 98.5% and 88.8%, respectively, while their RTE differs by an order of magnitude (1.4% and 16.4%). The COP should therefore always be interpreted together with its decomposition.
Table 2. Lead concepts and decomposition of the COP into electrical, heating, and cooling shares according to Equations (4)–(7). All lead concepts use air as the working fluid.
Figure 19. Decomposition of the COP of the lead concepts into the electrical share (COPel = RTE), the heating share (COPH), and the cooling share (COPC).
The selection of the lead concepts reflects the trade-off between thermal output (COP) and electrical efficiency (RTE). Within the feasible configurations of the respective application and COT, all lead concepts except CHP2 lie on the Pareto front of COP and RTE, with CCP1 within 0.1 percentage points. CHP2 is dominated by configurations that achieve at most 1.0 percentage point higher COP and 3.6 percentage points higher RTE, most of which require a recuperator or a working fluid other than air; within this small margin, the structurally simpler configuration was preferred. In general, the configuration with the highest or nearly the highest COP was selected from the Pareto set; CHP+WHI3 was added deliberately as a configuration with a considerably higher RTE at a moderately lower COP.
Table 3 lists the complementary indicators of the lead concepts according to Equations (8) and (9). Related to the total energy input, including the waste heat, the COP of the concepts with waste heat integration decreases from 103.1%, 98.5%, and 88.8% to 89.9%, 87.1%, and 82.8%, respectively, i.e., to values comparable to those of the concepts without waste heat integration (81.2–87.6%). The COP values above 100% are thus attributable to the externally supplied waste heat, which amounts to 7–15% of the charging work, whereas the storage system itself performs similarly with and without waste heat integration. The exergetic efficiencies of the lead concepts lie within a narrow range of 36–48%. In contrast to the COP, they rate CHP1 and CHP2 as practically equivalent (46.6% and 46.9%), and CHP+WHI3, which has the lowest COP of the concepts with waste heat integration, achieves the highest exergetic efficiency (48.2%) owing to its higher electrical share. The cooling share contributes less than 1 percentage point to the exergetic efficiency of the CCP concepts, which illustrates why an exergetic indicator is not suitable as the primary criterion for applications with cooling demand (Section 2.2).
Table 3. Complementary indicators of the lead concepts: waste heat related to the charging work, COP, COP related to the total energy input (Equation (9)), and exergetic efficiency (Equation (8)).
Figure 20 and Figure 21 summarize the maximum RTE and COP values of all applications for both compressor outlet temperatures.
Figure 20. Summary of results—maximum values for RTE and COP of the different applications at COT = 450 °C (state of the art). E: electricity only. Maximum RTE and maximum COP of an application may result from different configurations.
Figure 21. Summary of results—maximum values for RTE and COP of the different applications at COT = 625 °C (under development). E: electricity only. Maximum RTE and maximum COP of an application may result from different configurations.

3.6. Comparison with the RTU-Based Assessment

To show how the revised indicator changes the interpretation of the results compared with [1], the feasible configurations were ranked by RTU and by COP. The rank correlation between both indicators is weak, with Spearman coefficients of 0.28 for CHP, 0.08 for CHP+WHI, 0.42 for CCP, and 0.44 for CCP+WHI. Consequently, the selection of the best configurations changes considerably: in all groups with more than ten feasible configurations, only four to seven of the ten best configurations coincide. For example, CHP+WHI2, which achieves the highest COP at COT = 450 °C with waste heat integration, ranks last of eight configurations in terms of RTU, and CCP2 ranks eighth of twenty. The RTU favours configurations that supply a large part of their thermal output during charging, as these outputs reduce its denominator (Equation (2)). As a result, the RTU-optimal configurations for electricity and cooling achieve RTE values of only 24% and 31% at COT = 450 °C and 625 °C, respectively, compared with 36% and 43% for the COP-optimal ones. The COP thus leads to lead concepts with considerably higher electrical efficiency for comparable thermal output.

4. Discussion

The results reveal a pronounced trade-off between COP and RTE, which can be explained by the temperature levels at which the thermal services are provided. Process heat at 250 °C can only be extracted where the working fluid is hotter than 260 °C, for example, after the compressor in the charge line (CHP1) or downstream of the compressor in the discharge line (CHP2). This heat competes directly with the high-temperature energy required for charging the HT-TES and for power generation, so that a high heating share inevitably reduces the RTE (Figure 19). Cooling at 6 °C, in contrast, is provided at the cold end of the cycle, e.g., after the turbine in the charge path in CCP1 and CCP2, where low temperatures arise from the expansion anyway. Cooling therefore hardly competes with power generation, which explains why the CCP concepts retain RTE values of up to 45%, close to those of pure electricity generation, whereas their COP remains moderate.
Waste heat integration acts differently in the two applications. In the coupled generation of electricity and heat, waste heat at 90 °C is supplied on the low-temperature side of the cycle and, in the same way as the source heat of a heat pump, does not enter the denominator of the COP. Part of it is upgraded to process heat, which explains COP values above 100%. With RTE values of about 1%, CHP+WHI1 and CHP+WHI2 operate essentially as high-temperature heat pumps with integrated storage, and they should therefore be assessed against such systems rather than against electricity storage. In the coupled generation of electricity and cooling, additional heat at 90 °C has no useful sink: it does not contribute to the cooling at 6 °C and has to be rejected again. This is consistent with the observation that waste heat integration increases the number of feasible solutions but does not improve COP or RTE in this application. The waste heat amounts to 7–15% of the charging work of the lead concepts (Table 3). A reduced or intermittent availability therefore lowers the COP accordingly, whereas a lower waste heat temperature can render the integration infeasible if the required temperature differences in the heat exchangers can no longer be maintained. The effects of variable waste heat availability and temperature will be investigated in the dynamic simulations.
The influence of the working fluid on the pressure ratio follows from the isentropic relation T2/T1 = Π(κ−1)/κ. Owing to its higher isentropic exponent (κ ≈ 1.67 compared with 1.4 for air), argon reaches the same temperature lift with a considerably lower pressure ratio, which explains the lower pressure ratios of the argon concepts. Open cycles, in contrast, draw air at ambient temperature, so that the entire temperature lift to the COT has to be generated by compression. With the assumed isentropic efficiency, this requires pressure ratios of about 22 for a COT of 450 °C and about 48 for 625 °C (simulated: 25.0 and 53.5; feasible open-cycle concepts at 450 °C only exist for pure electricity generation, whereas the open-cycle concepts for the coupled generation of electricity and heat in Figure 2 are only feasible at 625 °C), whereas closed cycles start compression from an elevated temperature level. This explains both the high pressure ratios and the low performance of the open-cycle concepts. Similarly, a recuperator in the charge line raises the compressor inlet temperature, so that the required temperature levels for charging the HT-TES and for providing process heat at 250 °C can also be reached with a COT of 450 °C; without a recuperator, feasible concepts for this application only exist at 625 °C.
For the design of Brayton batteries for multi-purpose applications, these findings imply that the choice of concept should be based on the ratio of electricity to thermal demand rather than on the COP alone. Where electricity is the main product, the CCP concepts or CHP2 and CHP+WHI3 are favourable, as they combine a relevant thermal output with a noticeable RTE. Where heat is the main product and waste heat is available, CHP+WHI1 and CHP+WHI2 achieve the highest COP but provide almost no electricity. In all cases, air in a closed cycle at moderate pressure ratios proved sufficient, which favours robust and cost-effective designs. It should be noted that the absolute values are based on idealized assumptions, in particular, the neglect of pressure and heat losses (Table 1); the dynamic system simulations of the lead concepts currently under way will quantify these effects.
Over the past years, the development of Carnot battery technology has steadily progressed. Research initiatives identified at the start of this project have advanced further. For instance, the National Facility for Pumped Heat Energy Storage (Newcastle University, UK) showcased a 150 kW system at grid scale, originating from the technology of Isentropic Ltd. [26]. Meanwhile, the CHESTER project (EU Horizon 2020) successfully developed a 10 kWe laboratory-scale prototype [27], and Malta Inc. (Cambridge, USA) worked on a 100 MW grid-scale solution [28]. Novotny et al. [29] provide an overview of commercial activities in this field.
Beyond prototype and demonstration projects, a growing number of publications have explored specific system configurations and their distinct aspects. However, apart from the previous study [1], on which the present work builds, no studies with a comparable systematic conceptual approach have been identified. Table 4 compares the present work with [1] and the most closely related studies.
Table 4. Comparison of the present work with the previous study [1] and the most closely related studies.
A direct comparison with existing simulation studies in the literature is not feasible due to the lack of directly equivalent concepts. Differences in boundary conditions, assumptions, and system topologies make such comparisons challenging. Additionally, the positioning of heat exchangers varies significantly among the concepts discussed in the literature.
The results are subject to the simplifying assumptions of the stationary model (Table 1). First, ideal-gas behaviour was assumed. For air, the compressibility factor deviates from unity by less than 1% in the relevant range up to 13 bar, so that the lead concepts, which all use air, are not affected. For CO2, the deviation is about 2% at 3.4 bar and 6–12% at 11–19 bar near ambient temperature, and it becomes large above approximately 60 bar, with compressibility factors of 0.14–0.30 at 15 °C, calculated with CoolProp [30]. The results of CO2 configurations with high pressure ratios, which occur only in pure electricity generation and in the coupled generation of electricity and cooling with waste heat integration, should therefore be regarded as qualitative; none of them were selected as a lead concept. Second, pressure and heat losses outside the thermal energy storages were neglected. Pressure losses reduce the expansion ratio of the turbines; for an ideal-gas expansion of air, a total relative pressure loss of 1% reduces the specific turbine work by about 1.0% at Π = 2.5, but only by about 0.3% at Π = 10.6. Since the net work is the difference between turbine and compressor work, the relative effect on the RTE is larger, particularly for concepts with low pressure ratios such as CCP1 and CCP2. The reported RTE values in particular should therefore be regarded as upper limits. Third, a validation against experimental or pilot-scale data is not possible, as none of the analysed configurations have been built, and the existing demonstrators [26,27,28] use different topologies and boundary conditions. These effects will be quantified in the dynamic simulations of the lead concepts.

5. Conclusions

Building on the systematic structural analysis of more than 200,000 Brayton battery configurations in [1], this study re-evaluated the feasible configurations using the COP and its decomposition into electrical, heating, and cooling shares. These configurations covered a range of applications, from pure electricity generation to various forms of coupled electricity, heat, and cooling generation, with and without waste heat integration.
In pure electricity generation, round-trip efficiencies (RTEs) ranged between 20% and 50%, with systems operating at a compressor outlet temperature (COT) of 625 °C achieving higher efficiencies than those at 450 °C. No distinct trends emerged concerning the choice of working fluids or the presence of recuperators. Furthermore, incorporating waste heat did not lead to significant efficiency improvements.
When electricity was coupled with heat or cooling generation, overall efficiency improved, as reflected in higher coefficient of performance (COP) values. However, this came at the expense of RTE. The integration of waste heat enhanced COP for heat-providing concepts but had no comparable effect on cooling-focused configurations. While concepts with a COT of 450 °C generally exhibited lower RTE values than those with 625 °C, their COP values did not necessarily follow the same pattern. Open-cycle concepts yielded only a few feasible solutions, typically with lower efficiency. Including a recuperator in the charging line allowed for viable configurations in electricity and heat cogeneration at 450 °C. However, no physically viable solutions were identified for the simultaneous generation of electricity, heat, and cooling. The maximum achievable efficiencies for different applications are summarized in Figure 20 and Figure 21 (Section 3.5).
If a concept met the feasibility criteria, two to three leading configurations per application type were selected. These lead concepts consistently operated with air as the working fluid at relatively low pressures (<13 bar), with or without a recuperator in the charging line, and featured heat input and removal at various process stages. They were designed for operation at either 450 °C or 625 °C. These lead configurations will undergo further investigation through dynamic system simulations, focusing on component design and thermal energy storage. Additionally, future work will explore configurations capable of providing not only electricity but also heat and cooling, either concurrently or with a time delay.
The complementary indicators confirm these findings. Related to the total energy input, including the waste heat, the COP of the lead concepts with waste heat integration decreases to 83–90%, and the exergetic efficiencies of all lead concepts lie between 36% and 48%. Compared with the RTU used in [1], the COP leads to a considerably different ranking of the configurations and favours concepts with higher electrical efficiency.
Apart from the previous study [1], no directly comparable systematic simulation studies were found in the literature (Table 4), which highlights the distinctive contribution of the systematic structural analysis. The methodology enables the identification of highly efficient concepts optimized for specific parameter sets, often outperforming configurations from existing studies, which may not represent the best solutions for these conditions. This advantage is particularly evident in systems for coupled electricity and heat generation, as well as electricity and cooling, areas where published research remains limited.

Funding

This research was funded by the German Federal Ministry for Economic Affairs and Climate Action, grant number 03EI3045.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data presented in this study are available upon request from the author.

Acknowledgments

During the preparation of this manuscript, the author used Claude Opus 5.5 (Anthropic) for the purposes of adapting the manuscript to the journal template, drafting and revising text passages (in particular Section 2.2 and Section 2.3, and 3.5), checking and completing the bibliographic data of the references, designing the diagrams, and preparing the revision in response to the reviewers’ comments, including the additional evaluations of the existing simulation data. The author has reviewed and edited the output and takes full responsibility for the content of this publication.

Conflicts of Interest

The author declares no conflicts of interest.

Abbreviations and Nomenclature

The following abbreviations are used in this manuscript:
CCHPCoupled generation of electricity, heat, and cooling
CCPCoupled generation of electricity and cooling
CHPCoupled generation of electricity and heat (combined heat and power)
COPCoefficient of performance
COTCompressor outlet temperature
HT-TESHigh-temperature thermal energy storage
KPIKey performance indicator
LT-TESLow-temperature thermal energy storage
PHESPumped heat energy storage
PTESPumped thermal electricity storage
RTERound-trip efficiency
RTURound-trip utilization
STERSeasonal total efficiency ratio
TERTotal efficiency ratio
WHIWaste heat integration
The following symbols are used in this manuscript:
SymbolDescription
COPCoefficient of performance (%)
COPel, COPH, COPCElectrical, heating, and cooling share of the COP (%)
COPtotCOP related to the total energy input, including waste heat (%)
QHeat
QH, QCUseful heat and useful cooling supplied to consumers
QWHExternally supplied waste heat
TTemperature (K)
WWork
ZCompressibility factor (–)
ηEfficiency (–)
θCarnot factor (–)
κIsentropic exponent (–)
ΠCompressor pressure ratio (–)
ψExergetic efficiency (%)
Subscripts
0Ambient
c, dCharging, discharging
C, HCooling, heating
Comp, TurbCompressor, turbine
elElectrical
WHWaste heat

References

  1. Krüger, M. Systematic Concept Study of Brayton Batteries for Coupled Generation of Electricity, Heat, and Cooling. Appl. Sci. 2024, 14, 6073. [Google Scholar] [CrossRef] [Scilit]
  2. Vandersickel, A.; Ludwig, K. Carnot Battery Development—State of the Art & Prospects. In Proceedings of the 4th International Workshop on Carnot Batteries, Stuttgart, Germany, 23–25 September 2024. [Google Scholar]
  3. Tang, J.; Li, Q.; Werle, S.; Wang, S.; Yu, H. Development and comprehensive thermo-economic analysis of a novel compressed CO2 energy storage system integrated with high-temperature thermal energy storage. Energy 2024, 303, 131941. [Google Scholar] [CrossRef] [Scilit]
  4. Zhao, Y.; Huang, J.; Song, J.; Ding, Y. Thermodynamic investigation of a Carnot battery based multi-energy system with cascaded latent thermal (heat and cold) energy stores. Energy 2024, 296, 131148. [Google Scholar] [CrossRef] [Scilit]
  5. Neises, T.; McTigue, J. Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power. J. Eng. Gas. Turbines Power 2025, 147, 021008. [Google Scholar] [CrossRef] [Scilit]
  6. Huang, J.; Zhao, Y.; Song, J.; Wang, K.; Zhu, P.; Liu, B.; Sun, P. Thermodynamic investigation of a Joule-Brayton cycle Carnot battery multi-energy system integrated with external thermal (heat and cold) sources. Appl. Energy 2025, 377, 124652. [Google Scholar] [CrossRef] [Scilit]
  7. Shamsi, S.S.M.; Barberis, S.; Maccarini, S.; Traverso, A. Thermo-economic performance evaluation of thermally integrated Carnot battery (TI-PTES) for freely available heat sources. J. Energy Storage 2024, 97, 112979. [Google Scholar] [CrossRef] [Scilit]
  8. Lu, M.; Du, Y.; Yang, C.; Zhang, Z.; Wang, H.; Sun, S. Performance analysis and multi-objective optimization of a combined system of Brayton cycle and compression energy storage based on supercritical carbon dioxide. Appl. Therm. Eng. 2024, 236, 121837. [Google Scholar] [CrossRef] [Scilit]
  9. Wang, K.; Shi, X.; He, Q. Thermodynamic analysis of novel carbon dioxide pumped-thermal energy storage system. Appl. Therm. Eng. 2024, 255, 123969. [Google Scholar] [CrossRef] [Scilit]
  10. Wang, F.; He, Q. Thermodynamic analysis of pump thermal energy storage system with different working fluid coupled biomass power plant. Energy 2025, 318, 134758. [Google Scholar] [CrossRef] [Scilit]
  11. Benvenuti, M.; Frate, G.F.; Ferrari, L. Capital cost reduction in thermomechanical energy storage: An analysis of similitude-based reversible Brayton systems. Energy Convers. Manag. 2024, 321, 119050. [Google Scholar] [CrossRef] [Scilit]
  12. Alsagri, A.S.; Rahbari, H.R.; Wang, L.; Arabkoohsar, A. Thermo-economic optimization of an innovative integration of thermal energy storage and supercritical CO2 cycle using artificial intelligence techniques. Process Saf. Environ. Prot. 2024, 186, 1373–1386. [Google Scholar] [CrossRef] [Scilit]
  13. Guccione, S.; Guedez, R. Techno-economic analysis of power-to-heat-to-power plants: Mapping optimal combinations of thermal energy storage and power cycles. Energy 2024, 312, 133500. [Google Scholar] [CrossRef] [Scilit]
  14. Shamsi, S.S.M.; Barberis, S.; Maccarini, S.; Traverso, A. Large scale energy storage systems based on carbon dioxide thermal cycles: A critical review. Renew. Sustain. Energy Rev. 2024, 192, 114245. [Google Scholar] [CrossRef] [Scilit]
  15. Liu, Z.; Zheng, K.; Bai, C.; Yan, X.; Zhang, Y. Feasibility of transcritical pumped thermal energy storage system bottoming at ambient temperature. Appl. Therm. Eng. 2025, 268, 126000. [Google Scholar] [CrossRef] [Scilit]
  16. Linares, J.I.; Arenas, E.; Montes, M.J.; Cantizano, A.; Pérez-Domínguez, J.R.; Porras, J. Direct coupling of pressurized gas receiver to a Brayton supercritical CO2 power cycle in solar thermal power plants. Case Stud. Therm. Eng. 2024, 61, 105021. [Google Scholar] [CrossRef] [Scilit]
  17. Liu, Z.; Guan, H.; Shao, J.; Jin, X.; Su, W.; Zhang, H.; Li, H.; Sun, D.; Wei, T. Thermodynamic and advanced exergy analysis of a trans-critical CO2 energy storage system integrated with heat supply and solar energy. Energy 2024, 302, 131507. [Google Scholar] [CrossRef] [Scilit]
  18. McTigue, J.; Hirschey, J.; Ma, Z. Advancing pumped thermal energy storage performance and cost using silica storage media. Appl. Energy 2025, 387, 125567. [Google Scholar] [CrossRef] [Scilit]
  19. Wang, Z.; Liu, H.; Jiang, C.; Ji, Y.; Han, F. Assessment and optimization of a novel combined heat and power system through an energy nexus approach: Enhancing energy storage and sustainability. Energy 2025, 322, 135575. [Google Scholar] [CrossRef] [Scilit]
  20. Ayadi, B.; Jasim, D.J.; Anqi, A.E.; Aich, W.; Rajhi, W.; Marefati, M. Multi-criteria/comparative analysis and multi-objective optimization of a hybrid solar/geothermal source system integrated with a Carnot battery. Case Stud. Therm. Eng. 2024, 54, 104031. [Google Scholar] [CrossRef] [Scilit]
  21. Sharma, A.; Shukla, A.K.; Singh, O.; Sharma, M. Exergoeconomic, thermodynamic and working fluid selection analysis of a novel combined Brayton cycle-regenerative organic Rankine cycle for solar application. Int. J. Thermofluids 2025, 26, 101127. [Google Scholar] [CrossRef] [Scilit]
  22. Guan, J.; Han, W.; Liu, Q.; Jiao, F.; Ma, W. Proposal and analysis of an energy storage system integrated hydrogen energy storage and Carnot battery. Energy Convers. Manag. 2025, 332, 119734. [Google Scholar] [CrossRef] [Scilit]
  23. Eurovent. Seasonal Efficiency Index STER for Polyvalent Units; Eurovent Recommendation 18/1; Eurovent: Brussels, Belgium, 2023. [Google Scholar]
  24. Byrne, P.; Ghoubali, R. Exergy analysis of heat pumps for simultaneous heating and cooling. Appl. Therm. Eng. 2019, 149, 414–424. [Google Scholar] [CrossRef] [Scilit]
  25. European Union. Directive 2012/27/EU of the European Parliament and of the Council of 25 October 2012 on Energy Efficiency, Article 2(32) and 2(35). Off. J. Eur. Union 2012, L315, 1–56. [Google Scholar]
  26. Ameen, M.T.; Ma, Z.; Smallbone, A.; Norman, R.; Roskilly, A.P. Demonstration system of pumped heat energy storage (PHES) and its round-trip efficiency. Appl. Energy 2023, 333, 120580. [Google Scholar] [CrossRef] [Scilit]
  27. Theologou, K.; Johnson, M.; Tombrink, J.; Ciganda, J.L.C.; Trebilcock, F.T.; Couvreur, K.; Tassenoy, R.; Lecompte, S. CHESTER: Experimental prototype of a pumped thermal energy storage and management system with thermal integration. Energy Convers. Manag. 2024, 311, 118519. [Google Scholar] [CrossRef] [Scilit]
  28. Malta Inc. High Temperature Heat Pumps for Industry. Available online: https://www.maltainc.com/ (accessed on 9 November 2026).
  29. Novotny, V.; Basta, V.; Smola, P.; Spale, J. Review of Carnot Battery Technology Commercial Development. Energies 2022, 15, 647. [Google Scholar] [CrossRef] [Scilit]
  30. Bell, I.H.; Wronski, J.; Quoilin, S.; Lemort, V. Pure and Pseudo-pure Fluid Thermophysical Property Evaluation and the Open-Source Thermophysical Property Library CoolProp. Ind. Eng. Chem. Res. 2014, 53, 2498–2508. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.