Abstract
Improper cooling of food is a significant cause of foodborne illness, making the rapid refrigeration of hot foods an important preventive measure. However, this practice can affect temperature stability inside domestic refrigerators and influence the thermal conditions of other stored products. This study investigates the impact of placing hot food in domestic no-frost refrigerators on the temperature distribution within the unit and its effect on previously refrigerated items. A controlled thermal disturbance of approximately 1.1 MJ was introduced using a hot load at 62 ± 1 °C. The analysis considers parameters such as the stockpot’s position inside the refrigerated compartment (top, middle, and bottom), whether it is covered or uncovered, and the shelf type (glass or wire). These configurations were evaluated based on their impact on the core temperature of a dairy product placed on the door shelf. Results indicate that placing an uncovered hot stockpot on the top shelf resulted in the highest temperature increase for the dairy product, with a recorded rise of 6.8 °C from its initial temperature. Conversely, placing the stockpot on the bottom shelf minimized the impact, limiting the temperature increase to approximately 2.2 °C. For the investigated refrigerator and monitored dairy-product location, the largest differences in thermal response were associated with the position of the hot load, while lid presence and shelf configuration also influenced the measured response. The concept of Thermal Exposure Index (TEI) is introduced, which may be interpreted as the cumulative thermal burden experienced by the refrigerated product. Unlike peak temperature measurements, this index incorporates both the intensity and duration of the temperature excursion. Findings highlight the importance of adequate placement and handling of hot foods inside refrigerators to reduce temperature excursions and improve domestic food storage practices, allowing a more comprehensive assessment of the impact of different storage configurations on food temperature stability.
1. Introduction
Historically, improper cooling has been recognized as one of the leading factors contributing to foodborne illnesses [1]. According to the European Food Safety Authority (EFSA), 4005 foodborne outbreaks were reported in the European Union in 2021 [2]. Foods that have just been cooked are initially at high temperatures and require adequate cooling procedures to ensure food safety. During the cooling process, food products may remain for a significant period within temperature ranges favourable to microbial growth; therefore, time–temperature control is essential for maintaining food quality and preventing foodborne illness [3].
To lower food temperature to safe levels, refrigeration is a standard practice and plays a key role in food safety [3,4]. There is, however, a prevalent belief among kitchen professionals and those familiar with household appliances that hot food should not be placed in the refrigerator [5]. Although rapidly cooling hot foods is not their primary function, refrigerators are designed to cool and preserve food, including items that have just been cooked. This ensures that users do not have to wait for food to reach ambient temperature before refrigerating it [6]. Conversely, several refrigerator user manuals state that hot food should not be placed inside, as it can affect the appliance’s operation [7]. This may be because it either places additional load on the low-pressure side of the refrigeration cycle—leading to higher-than-normal discharge pressures and temperatures—or it may compromise the safety of other stored food due to insufficient refrigeration capacity [8]. Placing hot food inside the cooler raises the internal cabinet temperature, forcing the compressor to work harder and longer; this may result in inadequate cooling efficiency [9]. This is caused by increased heat loads and heat transfer mechanisms, specifically convection and condensation [10]. The latter occurs due to the temperature differential between water vapour and the refrigerator walls, leading to droplets that must be removed by the evaporator. In fact, condensation adds moisture to the environment, which is detrimental to food preservation [11,12]. Despite these technical limitations, food safety regulations establish that leaving food out of the refrigerator allows bacteria to grow and cause spoilage [13]. Food should be kept at room temperature for a maximum of two hours after cooking [14]. After this period, bacteria may proliferate, potentially leading to food poisoning [15,16]. However, two hours may not be sufficient to cool items like recently boiled soup to an acceptable temperature [17]. Consequently, after two hours, food must be refrigerated immediately, even at a considerably higher temperature than the surrounding products.
Because high thermal loads are frequently found in the use of refrigerators, the refrigeration machine has to deal with this adverse operation condition and must be able to provide the refrigerator with the cooling capacity it needs in order to keep temperatures low enough for a safe period of time [18,19]. The potential variation in refrigerator efficiency also plays an important role [20]. The temperature distribution and its variation over time is particularly important for refrigerators and is detrimental for the maintenance of temperatures. It will not only affect the preservation of foods, but also affect the performance of the system. Manufacturers have enhanced the performance of refrigerators to comply with more demanding operating conditions like high energy efficiency and temperature distribution [3]. Ventilated refrigerators or changes in the design of the air duct from central direction to side direction are technologies that have proven to contribute to a more uniform temperature distribution, even in the worst-case scenario of hot foods being placed inside the cabinet [21]. Researchers have largely studied this issue. Research by [22] conducted an experimental study where temperature–time curves were drawn for the cooling of “chilli con carne”, a dish containing beans and ground meat, subjected to six different cooling methods including a walk-in refrigerator, a blast chiller and ice sticks. In this study the authors have also varied the size of the container the food was packaged in and found that cooling methods often found in schools were not sufficiently effective in cooling hot food according to the recommendations of the 2001 Food Code standards. Research found that the blast chiller is the equipment that complied with those regulations despite its higher cost.
Ref. [23] collected data from 50 restaurants regarding the temperature of food at the beginning and end of the cooling observation period. They used these two time points to estimate cooling rates. Results showed that approximately one-third of the restaurants had an estimated cooling rate slower than the Food Code guidelines. However, many observations revealed cooling rates that were only slightly below the recommended levels, suggesting that many establishments may only need to make minor adjustments to their cooling practices to achieve compliance.
In the study by [22], the effect of cooling was investigated using covered and uncovered containers across twelve different cooling methods. The experiments also varied the depth and material of the containers. Furthermore, covered containers—or “unventilated,” as the author labels them—took significantly longer to cool than ventilated (uncovered) methods.
Ref. [24] compared the cooling rates of a household refrigerator and a blast chiller using pans previously heated to at least 71 °C. The study compared four types of food—soup, mashed potatoes, pasta, and peas—stored in containers of equal weight. Results showed that the household refrigerator’s capacity was unable to keep up with the additional heat load, as the air temperature remained in the “danger zone” for more than two hours. In contrast, the blast chiller was much more efficient, bringing the temperature down to below 3 °C within three hours. These findings raised concerns regarding the temperature rise of other products inside the refrigerator, a limitation that was not observed when using the blast chiller.
While previous studies have focused on the cooling rate of hot food [4,25,26], limited quantitative information is available regarding the transient thermal risk imposed on already refrigerated products located in different regions of domestic appliances. Understanding how the introduction of hot food influences the temperature distribution of other products is essential, as localized temperature increases can compromise the microbiological quality of perishable foods. Domestic no-frost refrigerators rely on forced air circulation to maintain uniform temperatures, but sudden high heat loads may create transient thermal gradients that exceed recommended storage limits. Therefore, this study aims to quantify the temperature changes in both the air and a small portion of food after hot items are placed in a domestic no-frost refrigerator. The measured temperature profiles are subsequently compared with the cold storage limits defined under EU Regulation (EC) No. 852/2004 [27], which provide a reference framework for safe chilled food storage in HACCP-based systems.
2. Experimental Analysis
2.1. Experimental Setup
Experimental tests were performed to evaluate the ability of a household refrigerator to maintain the temperature of a dairy product when a hot stockpot is placed inside the fresh food compartment. This refrigerator comprises two main compartments: a fresh food section and a freezer. The fresh food section is located at the bottom of the unit, whereas the freezer is at the top. Heat transfer between the air and the food occurs primarily through forced convection, as the airflow is generated by a fan located inside a plenum on the back wall of the fresh food compartment. The extraction openings are at the bottom of the cabinet, while the supply outlets are located at the top of the compartment, along with other small openings on the side of the plenum that also discharge cold air. The main technical specifications of the refrigerator used in the tests are shown in Table 1.
Table 1.
Main specifications of the refrigerator. Note: Dimensions are given by the inside of the cabinet.
2.2. Experimental Procedure
To test the cooling capacity of the refrigerator when hot food is introduced, ten different experiments were performed. The parameters varied in the tests were the position of the hot stockpot (top, middle, or bottom), whether the stockpot was covered or uncovered, and the type of shelf. Shelf construction varied by material and design, using either glass or wire. A cup containing 120 g of a dairy product (yogurt) was placed on the door shelf, and the effect of each test configuration on its core temperature was analyzed. The position of the smaller cup remained constant throughout all experiments. The refrigerator used in the tests allowed for interchangeable shelves—glass and wire types—to analyze the influence of these two configurations on maintaining the temperature of the dairy product when subjected to a sudden increase in heat load. Figure 1 shows the experimental setup. The heat load consisted of a stainless steel stockpot half-filled with water at 62 ± 1 °C. The heat load was placed at three different heights to study the efficiency of the cooling equipment in scenarios encountered during daily use. This occurs when a user places the stockpot on the top, middle, or bottom shelves, depending on the size of the pot or the available space. The tests also take into account whether the stockpot is kept inside the refrigerator with or without its lid.
Figure 1.
Positioning of the stockpot in the tests (except case 4) and location of the thermocouples T1 and T2 (for air temperature) and T3 (for food temperature).
The stockpot had a height of 150 mm and a diameter of 240 mm and was filled with water up to a height of 107 mm, resulting in an approximate water volume of 4.8 L and a mass of approximately 4.8 kg (Figure 2). The sensible thermal energy introduced into the refrigerator was estimated using [10]:
where m is the water mass, cp is the specific heat capacity of water (4.18 kJ kg−1 K−1), Ti is the initial water temperature (62 °C), and Tref represents the reference refrigerated temperature (5 °C). Based on these assumptions, the thermal disturbance imposed on the refrigerator was approximately 1.1 MJ. The thermal contribution of the stainless steel container was not considered in this estimation, since the water mass represented the dominant contribution to the imposed heat load.
Figure 2.
Dimensions of the stockpot (a) and the yogurt cup (b) used in tests (not to scale).
This emulates two situations occurring in many kitchens, as there is a general belief among cooks that a hot stockpot or soup may cool down faster if left uncovered inside a refrigerator, despite the risk of cross-contamination [28]. Conversely, covering a pot will slow the cooling rate of the hot product; however, the heat transfer rate to the compartment and other foods will also be mitigated, leading to more controlled internal temperatures over time. Table 2 presents the location of each thermocouple, the position of the stockpot and yogurt cup in each test configuration, and the placement of the shelves, according to the axes shown in Figure 2.
Table 2.
Locations of the instrumentation, the stockpot and the shelves in the tests.
Each experiment began when the hot stockpot was placed inside the refrigerator and the door was closed. The duration of each test was determined by the inflection point of the dairy product’s temperature—specifically, when the yogurt’s temperature ceased rising and began to stabilize. This stabilization occurs as the cooling air circulated by the fan reduces the internal temperature gradient. During the tests, no manual override was applied to the compressor, evaporator fan, or defrost system. Therefore, the appliance’s control unit was solely responsible for managing the cooling system to accommodate the increased heat load and maintain the setpoint temperature. The test conditions are summarized in Table 3.
Table 3.
Coding and characteristics of each test.
The first digit of the test case identifier refers to a covered stockpot (values 1 or 3) or an uncovered one (value 2). The second digit indicates the pot’s position: 1 for the top shelf, 2 for the middle shelf, and 3 for the bottom of the refrigerator. Case 4 represents a baseline experiment in which no heat load was used, serving as a control for comparison between tests. The refrigerator under study is equipped with sensors to measure key parameters, such as air and food temperatures. The instrumentation comprises three T-type thermocouples and a data logger (Datataker model DT 85). Two thermocouples, T1 and T2, were positioned at different heights inside the refrigerated compartment to characterize the spatial and temporal response of the cabinet air to the introduction of the hot load, while thermocouple T3 was immersed in the yogurt to measure the core temperature of a representative refrigerated food product. The yogurt was positioned on the door shelf to represent a common domestic storage location for dairy products, particularly milk containers. A dairy product was selected because of its perishable nature and sensitivity to refrigerated-storage temperature. Consequently, T1 and T2 were used to characterize the propagation of the thermal disturbance within the compartment, whereas T3 quantified the resulting thermal response of the selected refrigerated food. A single food sample at a fixed location was intentionally used as a common thermal-response reference across all configurations; consequently, T3 should not be interpreted as representing the temperature response of food products at all possible storage locations. The yoghurt was kept inside the refrigerator at all times. For that reason, its initial temperature can be approximately the same as the average temperature of the air inside the refrigerator at the beginning of the experiments.
The methodology for these calculations followed the procedures of the Guide for Calculation in Uncertainty Measurement [29]. The expanded uncertainty was estimated using a Type A methodology—i.e., using data from a set of tests performed by a certified laboratory.
Consequently, the measurement chain used in the experiments was calibrated, and the expanded uncertainty was estimated based on a 95% confidence interval, yielding Um = ±0.3 K.
The experiments were conducted in a laboratory under uncontrolled ambient conditions. However, the ambient air temperature during the tests was 24 ± 1 °C.
The combined uncertainty includes the effect of ambient temperature variation and heat load temperature variation and it can be estimated by uncertainty propagation.
The main variable in this study is the air temperature inside the refrigerator Y which is given by:
where:
Tm = measured temperature;
Tamb = ambient temperature;
Tload = heat load temperature.
Each previous variable has an associated standard uncertainty:
With the contribution of each variable ci depending on how much the output Y changes when the variable xi varies.
The combined uncertainty is given by
Each uncertainty can be estimated by multiplying its contribution by the respective standard uncertainty
According to [14], the contribution of the ambient temperature on the interior temperature of the refrigerated box is camb = 0.17 °C/°C. The sensitivity coefficient associated with the load temperature was taken as unity (cload = 1 C/°C). The load is located inside the refrigerated compartment and exchanges heat directly with the cavity air. Therefore, a variation of 1 °C in the load temperature corresponds to an equivalent 1 °C variation in the thermal condition imposed within the cavity. The resulting combined standard uncertainty was 0.61 °C, corresponding to an expanded uncertainty of 1.21 °C for k = 2.
During all hot-load experiments, the refrigerator compressor was continuously operating as confirmed by its clearly audible operation throughout the tests. Since the experiments were conducted while the refrigerator was actively cooling, no indication of a defrost phase was observed during the measurement periods. Therefore, the temperature responses reported for the hot-load tests are not expected to have been affected by defrost heating.
3. Discussion
3.1. Tests Performed
Temperatures measured by sensors T1, T2, and T3 are presented as temperature differences, ΔT1, ΔT2, and ΔT3. This representation was adopted to facilitate the comparison among the different scenarios. Another, practical reason, arises from the limitation of achieving identical initial temperatures for the air (T1 and T2) and the yogurt (T3) due to air stratification, varying compressor and fan operating states imposed by the control system, and the thermal inertia of refrigerator components, including walls and heat exchangers.
Expressing the results as temperature differentials rather than absolute values facilitates direct comparison between experimental runs. Each temperature difference, ΔTn, was calculated as follows:
where is the temperature of the sensor n at the instant t = 0 s. Figure 3 shows the evolution of temperature differences ΔT1, ΔT2 and ΔT3 over a period of time for cases 1.1, 1.2 and 1.3.
Figure 3.
Temperature difference ΔT1, ΔT2 and ΔT3 in cases 1.1, 1.2 and 1.3.
Figure 3 shows that the highest temperature difference measured by sensor T3 occurred in case 1.1. This is because the hot stockpot is very close to the yogurt when positioned at the highest position of the refrigerator. This observation may also be attributed to airflow blockage, since the stockpot obstructs the supply of cold air that allows efficient and complete cooling of the yogurt. On the other hand, it is observable in Figure 3 that the air temperature at location T1 presents a minimum ΔT1 of −7.5 °C which was reached at 48 min. However, this decrease in temperature is not reflected in ΔT3 inside the yogurt. This can be explained by the fact that temperature sensor T1 is located close to the cold air outlet in test 1.1 while sensor T3 is located at the door in front of the thermal load, immersed inside a liquid. As a consequence, temporary decreases in the measured local air temperature occur after the thermal load has been introduced, leading to negative ΔT1 and ΔT2 values at certain time intervals.
In contrast, the yogurt temperature (ΔT3) exhibits a more predictable behaviour when a hot load is placed inside the refrigerator cabinet. This is because yogurt is a dense and highly viscous fluid with considerable thermal inertia, its temperature responds more slowly to environmental fluctuations. The overall trend observed in ΔT3 is a temperature increase.
In case 1.2, the stockpot was placed in a central position inside the refrigerator. The results of this test indicate a significant increase in air temperature difference ΔT2. Maximum ΔT2 values of 8.1 °C were reached 16 min after the beginning of the test. After this moment, the cold system manages to reverse the upward trend in air temperature, and the curve follows a downward trajectory until reaching a minimum ΔT1 value of −4.2 °C. This behaviour is replicated in the evolution of the ΔT2 temperature difference. However, because the hot pan is placed on a different shelf where the sensor is located, the final value of these differences becomes positive when it was mostly negative in ΔT1. It should be noted that the cold air slots that deliver more air flow are placed in the compartment between the upper shelf and the ceiling of the refrigerator, so it makes sense that the ΔT1 temperatures are, for the most part of the test, negative. The refrigerator is equipped with cold air slots scattered by the console with varying areas and discharge directions. In the upper zone the air flow is blown in a direction pointing to the door, whereas in the middle of the cabinet the slots are intended to project the air to the sides, having less cooling capacity than the ones which are placed in the upper zone. This might explain the different results in tests 1.1 and 1.2. Regarding the temperature in the food (temperature sensor T3), there is an identical behaviour of this variable compared to what happened in case 1.1, i.e., an increase from the initial temperature to a maximum of 1.6 °C. However, this maximum value is lower than that observed in case 1.1.
In test 1.3, the hot load is placed at the floor of the refrigerator. Among cases 1.1, 1.2 and 1.3, this test reveals that the temperature of the yogurt was the least affected by the introduction of the hot load. The temperature difference ΔT3 is always negative since the test start, which indicates a more efficient cooling of the yogurt when a hot load is placed at the bottom of the refrigerator. This occurs due to the air impermeability of the glass shelves, which makes the impact thermal load difficult to be felt in different zones other than the where the thermal load is located. Therefore, in this situation, the refrigeration system can lower the ΔT3 temperature difference more efficiently when a hot pan is placed in the lowest area of the refrigerator. An increase in temperature differences ΔT1 and ΔT2 is also noticeable from 30 min onwards. Such an increase may indicate that, after this time, the heat released by the pan must have had time to heat the lower glass shelf and increase the heat transfer to the cabinet.
Figure 4 shows the temperature differences ΔT1, ΔT2 and ΔT3 in cases 2.1, 2.2 and 2.3. In test 2.1, a stockpot without the lid is placed inside the refrigerator in the upper position. The immediate consequence of this configuration is the increase in temperature in the T3 sensor as seen before with case 1.1. However, while in cases 1.1, 1.2 and 1.3, the temperature difference ΔT3 did not exceed 2.6 °C, in test 2.1, in particular, the ΔT3 temperature difference reached almost 7 °C. This is because both heat and mass are being transferred from the hot water to the compartment at a rate that exceeds the latent and sensible cooling capacity of the evaporator. Even so, after 50 min, the cooling and ventilation system manages to remove this additional thermal load, as seen in Figure 4. The amount of time needed for ΔT3 to stabilize is around 50 min in case 2.1. The ΔT1 air temperature values in Figure 4 reveal a sudden increase in air temperature that could be the cause of the increase in the temperature of ΔT3. Furthermore, values of ΔT1 of 4 °C and ΔT2 of 4.8 °C were verified against a maximum ΔT1 of 1 °C in case 1.1.
Figure 4.
Temperature differences ΔT1, ΔT2 and ΔT3 in cases 2.1, 2.2 and 2.3.
In test 2.2, the uncovered stockpot is placed in the central position inside the refrigerator. A maximum ΔT3 of 4.1 °C is observed, while in test 2.1 almost 7 °C was observed, as previously mentioned. Analysis of Figure 4 indicates a decrease in the temperature difference ΔT1 during the first 15 min of the test, reaching negative temperature differences, while in test 2.1 one may notice only positive differences throughout the test. In test 2.2 the hot load was moved to the shelf below and this transition appears to have less impact on the temperature rise in the area where the T1 probe is located. Test 2.3 presents similarities with test 2.2, particularly in what concerns ΔT1 and ΔT2 figures. Until approximately the 30-min mark, these variables show a strong correlation. From this moment on, there is an increase in the temperature difference ΔT1 in test 2.2. At the same time, it is verified that the magnitude of the temperature difference ΔT2 is greater in test 2.3 than in test 2.2. In test 2.3, a maximum ΔT2 difference of 6.2 °C is recorded while in test 2.2 a difference ΔT2 maximum was 5.5 °C. Figure 5 shows the temperature difference ΔT1, ΔT2 and ΔT3 in cases 3.1, 3.2 and 3.3.
Figure 5.
Temperature differences ΔT1, ΔT2 and ΔT3 in cases 3.1, 3.2 and 3.3.
In test 3.1, the glass shelves were replaced with wire shelves which have a much higher degree of air permeability. Regarding the differences in ΔT3 temperatures within the yogurt, these seem to replicate what happens in case 1.1. Temperature differences of 3.5 °C at most are observed in ΔT3 in test 3.1. It should be noted that the set of tests 3.1, 3.2, and 3.3 presents a common characteristic compared to the other sets (1.1, 1.2, 1.3, 2.1, 2.2 and 2.3) in the sense that it shows that the yogurt undergoes a greater temperature increase that is higher when the pan is placed in the upper position. On the other hand, the central and lower positions reveal smaller increases in temperature ΔT3. Regarding differences in air temperatures, ΔT1 has shown to be the most affected, reaching the highest magnitudes observed in this study. ΔT1 figures are even greater than in cases 2.1, 2.2 and 2.3 when the stockpot used in those tests was uncovered. Temperature differences of about 10 °C were reached at T1 about 25 min after the start of the test. However, the refrigerator mitigated this rise in temperature by reducing ΔT1 to 3.8 °C after around 50 min. Tests 3.2 and 3.3 exhibit similar patterns of variation, albeit with lower temperature magnitudes compared to 3.1, though. In test 3.2 it is even possible to verify an inflection point on the evolution of the temperature difference ΔT1 at the instant 47 min which coincides with the cutoff of the refrigerator compressor. In tests 3.2 and 3.3 the refrigerator manages to reach a temperature difference ΔT1 close to zero after 50 min of the test. Higher ΔT1 temperature differences are reported, though, compared to ΔT2 temperature differences, whatever the case (3.1, 3.2 and 3.3). This phenomenon was not observable in previous tests where glass shelves were used.
In case 4, the refrigerator is allowed to operate without any high-temperature load inside. In this case, the yogurt cup represents the only refrigerated product considered. As it can be seen from Figure 6, after almost 50 min, the yogurt decreased by 2.8 °C compared to its initial temperature. also highlights the disparity between the evolution of the temperature difference ΔT3 in test 4 and that in test 1.1. The differences observed in Figure 7 would be even greater when comparing test 4 with tests 2.1, 2.2 and 2.3. However, those comparisons are not presented here, as Figure 7 is intended solely to illustrate the impact of placing a hot stockpot inside the refrigerator versus an empty compartment.
Figure 6.
Temperature difference ΔT3 in cases 1.1, 1.2, and 1.3 and baseline condition (Case 4).
Figure 7.
Maximum positive temperature increase measured in the dairy product ΔT3,max for the different experimental configurations.
Table 4 summarizes the maximum temperature increase measured inside the dairy product for all experimental configurations. The results clearly demonstrate that the position of the hot load inside the refrigerator was the dominant parameter affecting the temperature stability of the stored product. The highest thermal disturbance was observed when the uncovered stockpot was positioned on the top shelf (Case 2.1), resulting in a maximum temperature increase of approximately 6.8 °C. Conversely, placing the hot load at the bottom of the refrigerator minimized the impact on the refrigerated product, independently of the shelf configuration or lid presence.
Table 4.
Summary of the maximum yogurt temperature variations under different experimental conditions.
Figure 7 summarizes the maximum temperature increase measured inside the dairy product under the different experimental configurations. Results show that the location of the hot load was the main parameter influencing the thermal disturbance imposed on the refrigerated product. The highest temperature increase was observed in Case 2.1, corresponding to an uncovered stockpot placed on the top shelf, resulting in a maximum ΔT3 of 6.8 °C. Conversely, placing the hot load at the bottom of the refrigerator substantially reduced the temperature increase, independently of the shelf configuration.
3.2. Influence of Operational Parameters on Food Temperature Stability
For the investigated refrigerator and monitored product location, the comparison of the experimental configurations suggests that the position of the hot load produced the largest differences in the measured thermal response. When the stockpot was placed on the upper shelf, the highest temperature increases were observed, reaching ΔT3,max values of 2.6 °C (Case 1.1), 6.8 °C (Case 2.1), and 3.7 °C (Case 3.1). This behaviour can be attributed to the interaction between the upward heat transfer from the hot load and the internal forced-air circulation pattern of the no-frost refrigerator, increasing the exposure of the dairy product to warmer air.
The presence of the stockpot lid also had a significant influence on the transient thermal response. Removing the lid increased the maximum dairy product temperature rise from 2.6 °C (Case 1.1) to 6.8 °C (Case 2.1) for the upper shelf configuration. This increase results from the combined effect of enhanced convective heat transfer and water evaporation from the uncovered hot load, which introduces additional latent heat and moisture into the refrigerated compartment.
The shelf configuration affected the distribution of the thermal disturbance inside the refrigerator. Wire shelves promote greater airflow circulation between compartments, whereas glass shelves partially restrict vertical air movement. However, the results indicate that the effect of shelf configuration was less relevant than the position of the heat source and the presence of the lid.
Overall, the results observed at the monitored location indicate that placing hot food containers on lower shelves and keeping them covered significantly reduces the temperature disturbance imposed on previously refrigerated products, contributing to improved domestic refrigeration practices and food safety management.
4. Heat Transfer Characterization of the Dairy Product
4.1. The Thermal Exposure Index
The thermal response of refrigerated food subjected to a transient heat disturbance depends on the intensity of heat exchange between the product and its surrounding environment [30]. This exchange is governed by a combination of heat transfer mechanisms, including convection with the circulating air, thermal radiation between surfaces, and indirect interactions associated with the presence of the hot load.
While the maximum product temperature provides useful information regarding the severity of a thermal disturbance, it does not account for the duration of the exposure. From a food preservation perspective, both temperature magnitude and exposure time contribute to the overall thermal burden imposed on the product. To address this limitation, a Thermal Exposure Index (TEI) was introduced as a cumulative indicator of thermal stress. The TEI quantifies the integrated deviation of the product temperature from a reference refrigerated storage temperature over the duration of the thermal event. Consequently, larger TEI values indicate a greater thermal load imposed on the product, resulting either from higher temperatures, longer exposure times, or a combination of both. The index therefore provides a useful measure of the thermal resilience of refrigerated food when subjected to transient heat disturbances and is calculated as follows:
or equivalently,
where T3 is the yogurt temperature, Tref the reference refrigerated temperature and tf the duration of the thermal event. From an engineering perspective, TEI may be interpreted as an integrated response variable linking refrigeration performance to food preservation. While traditional refrigeration analysis is based on instantaneous heat-transfer rates or cooling capacity, TEI incorporates both temperature magnitude and duration, providing a more representative measure of the actual thermal burden imposed on stored foods. Table 5 shows the results of the variables described in this section for each case tested.
Table 5.
Results of the Temperature Exposure Index (TEI) applied to the yoghurt in each case tested.
The TEI provide complementary information regarding the thermal response of the refrigerated product once it quantifies the cumulative thermal burden experienced by the product throughout the transient event.
For the covered stockpot configurations (Cases 1.1–1.3), a progressive reduction in TEI from 325.6 to 0 K·min. suggests that placing the hot load further away from the yogurt reduced the overall thermal disturbance.
The uncovered stockpot configurations (Cases 2.1–2.3) exhibited the highest thermal exposure, observed in Case 2.1 (TEI = 464.1 K·min), where the stockpot was placed on the upper shelf. The uncovered hot load released substantial sensible and latent heat into the refrigerated compartment, producing prolonged exposure of the yogurt to elevated temperatures. Cases 2.2 and 2.3 presented lower TEI values and suggest that the thermal disturbance reaching the yogurt was less severe.
A similar trend can be observed for the wire-shelf configurations (Cases 3.1–3.3 where a reduction in TEI from 330.4 to 255.4 K·min is found. However, the remaining uncovered configurations illustrate the additional information provided by TEI. Cases 2.2 and 2.3 produced TEI values of 316.2 and 336.1 K·min, respectively. Although the maximum yogurt temperature increase was greater in Case 2.2 than in Case 2.3, the slightly larger TEI in Case 2.3 indicates a greater cumulative positive temperature exposure over the analysed period. Thus, evaluation based exclusively on the maximum temperature increase would not fully describe the thermal history experienced by the refrigerated product.
4.2. Food Safety Assessment Based on Temperature Exposure Limits
Temperature control during refrigerated storage is one of the main factors affecting the microbiological stability and quality preservation of perishable food products. According to EU food hygiene regulations [27], food business operators must ensure that cold chain conditions are maintained and that temperature variations capable of compromising food safety are minimized. Although a single temperature threshold cannot directly define food safety, refrigerated storage temperatures around 5 °C are commonly adopted as a reference limit for highly perishable products.
To evaluate the potential impact of introducing a hot load into the refrigerator, the measured ΔT3 profiles were converted into absolute food temperatures considering three different initial dairy product temperatures: 3, 4, and 5 °C. These values represent typical operating conditions during a refrigerator control cycle, ranging from periods immediately after compressor operation to higher temperatures reached before the next cooling cycle begins. The calculated temperature evolutions are presented in Figure 8.
Figure 8.
Dairy product temperature evolution considering different initial storage conditions. The shaded region indicates temperatures above the recommended refrigerated storage limit of 5 °C.
The results show that the initial temperature of the refrigerated product strongly influences its ability to remain within the recommended storage temperature range after the introduction of a hot load. Products initially stored at lower temperatures presented greater thermal resilience, delaying or preventing excursions above the 5 °C reference temperature. Conversely, when the initial product temperature was close to 5 °C, the additional thermal load caused longer periods above the recommended refrigeration range.
The most critical condition was observed when the uncovered stockpot was placed on the upper shelf (Case 2.1), where the combination of sensible and latent heat transfer resulted in the highest temperature increase. Nevertheless, after approximately 50 min, the refrigerator was able to stabilize the product temperature, indicating that the cooling system was capable of recovering from the imposed transient thermal disturbance.
It should be noted that exceeding the 5 °C reference temperature does not directly indicate food spoilage or unsafe conditions, as microbial growth depends on several additional factors, including food type, exposure duration, initial contamination level, and storage history. However, minimizing both the magnitude and duration of temperature excursions contributes to improved food safety management.
5. Limitations and Future Work
Although this study provides relevant experimental insights into the transient thermal response of refrigerated products after the introduction of hot food, some limitations should be acknowledged. The experiments were performed using a single domestic no-frost refrigerator model; therefore, different refrigeration technologies, internal geometries, control strategies, and airflow distributions may result in different thermal responses.
Each experimental configuration was tested once; consequently, the present dataset does not allow a statistical evaluation of test-to-test repeatability. The results should therefore be interpreted as a comparative and exploratory characterization of the thermal responses observed in the investigated refrigerator rather than as statistically generalized performance values. In particular, the quantitative differences reported between configurations apply to the experimental conditions and monitored locations considered here. Repeated measurements of identical configurations are required in future experimental campaigns to quantify run-to-run variability and establish confidence intervals for the reported thermal-response parameters.
The dairy product and thermocouple T3 were intentionally maintained at the same position throughout the experimental campaign to provide a common response location while varying parameters associated with the hot load, namely its position, lid condition, and shelf configuration. Consequently, the present study does not characterize the spatial variability of food temperature within the door shelf or throughout the refrigerated compartment. Small changes in product position may alter its thermal response because of local differences in airflow, temperature, and proximity to the thermal load. The results obtained for T3 should therefore be interpreted as representative only of the monitored location. Future work should systematically vary the position of the refrigerated product, including small horizontal and vertical displacements, together with repeated measurements, to quantify both spatial variability and experimental repeatability.
The thermal load was simulated using water inside a stainless steel stockpot because of its reproducibility and well-defined thermophysical properties, allowing comparable thermal disturbances to be imposed across the different experimental configurations. However, real foods can differ from water in specific heat capacity, thermal conductivity, density, viscosity, water content, and evaporation characteristics. These properties influence not only the total sensible energy stored in the hot product but also the rate at which this energy is transferred to the surrounding refrigerated environment. In particular, internal natural convection is generally more effective in low-viscosity liquids, whereas viscous or heterogeneous foods, such as thick soups and stews, can develop larger internal temperature gradients and may release their thermal energy more slowly. Consequently, two products with a similar mass and initial temperature may impose different transient heat loads on the refrigerator even when their total sensible thermal energies are comparable.
The present results should therefore be interpreted as characterizing the response of the refrigerator to a controlled, water-rich thermal load rather than providing quantitative temperature predictions applicable to all hot foods. Extrapolation is expected to be more representative of high-moisture liquid foods with thermophysical properties relatively close to those of water, whereas caution is required for viscous, heterogeneous, high-fat, or low-moisture products. Nevertheless, the experimental approach remains suitable for comparing the relative effects of stockpot position, lid presence, and shelf configuration under a reproducible thermal disturbance. Future studies should extend the methodology to representative food matrices, such as soups and stews, to determine how food composition influence the magnitude and duration of the thermal disturbance imposed on other refrigerated products.
Additionally, this study focused exclusively on the transient temperature response of refrigerated products. Although temperature excursions above recommended storage conditions were analyzed, no microbiological assessment was performed. Therefore, future work should combine thermal monitoring with microbiological analysis to establish a more direct relationship between transient temperature variations and food safety implications.
The TEI proposed here should not be interpreted as a direct microbiological risk index. Its physical significance is the accumulated temperature exposure of the refrigerated product relative to the selected reference condition of 5 °C. Thus, it complements maximum-temperature measurements by accounting for the duration of a thermal excursion. The 5 °C reference provides a practical baseline for comparing the experimental configurations but does not represent a universal threshold below which microbial growth is absent.
Finally, the impact of introducing hot food on refrigerator energy consumption was not evaluated. Further research including compressor operation, electrical consumption monitoring, and energy efficiency assessment would provide a more comprehensive understanding of the overall effects of this common domestic practice.
6. Conclusions
This study experimentally evaluated the impact of introducing hot food into a domestic no-frost refrigerator, focusing on the transient thermal response of previously refrigerated products. A controlled thermal disturbance of approximately 1.1 MJ was imposed by introducing a hot water load at 62 ± 1 °C under different operating configurations, including stockpot position, lid presence, and shelf design.
The results demonstrated that, in the tested unit, the position of the hot load inside the refrigerator was the dominant factor affecting the thermal stability of the refrigerated product. From a practical perspective, hot containers should be positioned as far as practicable from temperature-sensitive and highly perishable refrigerated products. In the refrigerator investigated here, positioning the hot load in the lower part of the compartment resulted in the smallest thermal disturbance of the dairy product located on the door shelf. The most critical condition occurred when the uncovered stockpot was placed on the upper shelf, producing a maximum temperature increase of 6.8 °C.
Among all configurations, the largest TEI was obtained for Case 2.1 (466.1 K·min), corresponding to the uncovered stockpot placed in the upper position. This result is consistent with the maximum temperature analysis, for which Case 2.1 also produced the greatest increase in yogurt temperature. The combination of a large temperature increase and prolonged exposure therefore makes this configuration the most severe thermal disturbance investigated.
However, the remaining uncovered configurations illustrate the additional information provided by TEI. Cases 2.2 and 2.3 produced TEI values of 316.2 and 336.1 K·min, respectively. Although the maximum yogurt temperature increase was greater in Case 2.2 than in Case 2.3, the slightly larger TEI in Case 2.3 indicates a greater cumulative positive temperature exposure over the analysed period.
In the tested unit the presence of a lid considerably reduced the thermal impact on stored products by limiting convective and evaporative heat transfer from the hot load. In contrast, the influence of shelf configuration was less significant, although differences between glass and wire shelves affected the internal airflow distribution and heat transfer mechanisms inside the refrigerated compartment.
From a practical perspective, the experimental results support several simple recommendations for domestic refrigerator users. When a hot container must be introduced into the refrigerator, placing it in the lower part of the refrigerated compartment is preferable to positioning it on the upper shelf, since this configuration produced the smallest thermal disturbance of the previously refrigerated product under the conditions investigated. The container should also preferably be covered, as the presence of the lid reduced the transfer of sensible and latent heat to the refrigerator compartment and consequently limited the temperature increase of surrounding refrigerated products. In the most severe configuration evaluated, corresponding to an uncovered hot load positioned on the upper shelf, the refrigerated product experienced a maximum temperature increase of 6.8 °C, whereas substantially lower disturbances were generally observed when the hot load was positioned lower in the compartment.
The 50 min period required for stabilization of temperature inside the food product should, however, be interpreted as the thermal recovery time of the investigated refrigerator and not as a universally safe food-cooling time. Safe cooling duration depends on the type and quantity of food, container geometry, initial food temperature, refrigerator performance, and microbiological characteristics. Further experiments maintaining a constant distance between the hot load and the refrigerated product while varying their relative vertical positions would help distinguish these effects.
Author Contributions
Conceptualization, M.L.; methodology, M.L. and J.G. (João Garcia); experimental campaign, M.L.; formal analysis, M.L., J.G. (João Garcia) and J.G. (João Gomes); writing—original draft preparation, M.L. and J.G. (João Garcia); writing—review and editing, M.L., J.G. (João Garcia), J.G. (João Gomes) and L.G.; funding acquisition, J.G. (João Gomes). All authors have read and agreed to the published version of the manuscript.
Funding
This research has been partly funded by the project AIRCOLES, Eureka Eurostars. Grant ID: E!8069.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The raw data supporting the conclusions of this article will be made available by the authors on request.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Fleischman, G.J. Thermal analysis of a low-tech passive sensor for the assessment of food cooling rate in refrigerators and freezers. J. Food Process Eng. 2018, 42, e12940. [Google Scholar] [CrossRef] [Scilit]
- U.S. Food and Drug Administration (FDA). Food Code 2022: Recommendations of the United States Public Health Service Food and Drug Administration; U.S. Department of Health and Human Services: Silver Spring, MD, USA, 2022.
- Muneeshwaran, M.; Yang, C.-M.; Nawaz, K.; Wang, C.C. Understanding airflow pattern and temperature distribution in domestic refrigerators—A review analyzing recent developments and bridging knowledge gaps. Sustain. Energy Technol. Assess. 2023, 57, 103171. [Google Scholar] [CrossRef] [Scilit]
- Van der Vossen-Wijmenga, W.P.; den Besten, H.M.W.; Zwietering, M.H. Temperature status of domestic refrigerators and its effect on the risk of listeriosis from ready-to-eat (RTE) cooked meat products. Int. J. Food Microbiol. 2024, 413, 110516. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Marshall, M. The refrigerator as a problem and solution: Food storage practices as part of sustainable food culture. Food Foodways 2022, 30, 261–286. [Google Scholar] [CrossRef] [Scilit]
- Rinkinen, J.; Shove, E.; Marsden, G. Conceptualising Demand: A Distinctive Approach to Consumption and Practice; Routledge, Taylor & Francis Group: Abingdon, UK, 2021. [Google Scholar]
- Sahakian, M. ‘More, bigger, Better’ household appliances: Contesting normativity in practices through emotions. J. Consum. Cult. 2019, 22, 21–39. [Google Scholar] [CrossRef] [Scilit]
- Harrington, L.; Aye, L.; Fuller, B. Impact of room temperature on energy consumption of household refrigerators: Lessons from analysis of Field and laboratory data. Appl. Energy 2018, 211, 346–357. [Google Scholar] [CrossRef] [Scilit]
- Harrington, L.; Aye, L.; Fuller, R.J. Opening the door on refrigerator energy consumption: Quantifying the key drivers in the home. Energy Effic. 2018, 11, 1519–1539. [Google Scholar] [CrossRef] [Scilit]
- Bari, M.A. Impact of air flow, temperature distribution, and heat transmission in a refrigerator compartment with and without shelves: A numerical approach. J. Therm. Eng. 2024, 10, 1590–1606. [Google Scholar] [CrossRef] [Scilit]
- He, G.; Liu, G.; Zhao, T.; Li, Y.; Yan, G.; Su, Z. Research progress on moisture transfer process and humidity control in small-scale food storage refrigeration devices. Energy 2025, 339, 138990. [Google Scholar] [CrossRef] [Scilit]
- Hoffmann, T.G.; de Souza, C.K.; Sonawane, A.D.; Praeger, U.; Büchele, F.; Neuwald, D.A.; Jedermann, R.; Linke, M.; Sturm, B.; Mahajan, P.V. Challenges and future perspectives in postharvest cold storage: Technological Review on sustainable and efficient cold storage of fresh produce. Food Res. Int. 2025, 221, 117406. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Andritsos, N.D.; Stasinou, V.; Tserolas, D.; Giaouris, E. Temperature distribution and hygienic status of domestic refrigerators in Lemnos Island, Greece. Food Control 2021, 127, 108121. [Google Scholar] [CrossRef] [Scilit]
- Belman-Flores, J.M.; Pardo-Cely, D.; Gómez-Martínez, M.A.; Hernández-Pérez, I.; Rodríguez-Valderrama, D.A.; Heredia-Aricapa, Y. Thermal and energy evaluation of a domestic refrigerator under the influence of the thermal load. Energies 2019, 12, 400. [Google Scholar] [CrossRef] [Scilit]
- Juneja, V.K.; Osoria, M.; Kapoor, H.K.; Gupta, P.; Salazar, J.K.; Shrestha, S.; Bag, S.K.; Mishra, A. A predictive growth model of Staphylococcus aureus during temperature abuse conditions. Food Res. Int. 2025, 206, 116032. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Martinez-Rios, V.; Idrizi, R.; Dalgaard, P.; Truelstrup Hansen, L.; Hansen, T.B. Modeling and predicting growth and growth boundary of bacillus cereus S.L. from Phylogroups II, IV, V, and VI in starchy foods at or below 12 °C. Front. Microbiol. 2025, 16, 1531014. [Google Scholar] [CrossRef] [Scilit]
- James, C.; Onarinde, B.A.; James, S.J. The use and performance of household refrigerators: A Review. Compr. Rev. Food Sci. Food Saf. 2016, 16, 160–179. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rinkinen, J.; Shove, E.; Smits, M. Cold Chains in Hanoi and Bangkok: Changing Systems of provision and practice. J. Consum. Cult. 2017, 19, 379–397. [Google Scholar] [CrossRef] [Scilit]
- Jofré, A.; Latorre-Moratalla, M.L.; Garriga, M.; Bover-Cid, S. Domestic refrigerator temperatures in Spain: Assessment of its impact on the safety and shelf-life of cooked meat products. Food Res. Int. 2019, 126, 108578. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ricardo Costa, N.; Garcia, J. Applying design of experiments to a compression refrigeration cycle. Cogent Eng. 2015, 2, 992216. [Google Scholar] [CrossRef] [Scilit]
- Salonen, A.S. Ordinary overflow: Food waste and the ethics of the refrigerator. Food Foodways 2022, 30, 145–164. [Google Scholar] [CrossRef] [Scilit]
- Olds, D.; Sneed, J. Cooling Rates of Chili Using Refrigerator, Blast Chiller, and Chill Stick Cooling Methods. J. Child. Nutr. Manag. 2005, 29. [Google Scholar]
- Schaffner, D.W.; Brown, L.G.; Ripley, D.; Reimann, D.; Koktavy, N.; Blade, H.; Nicholas, D. Quantitative Data Analysis To Determine Best Food Cooling Practices in U.S. Restaurants. J. Food Prot. 2015, 78, 778–783. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Litchforg, M.D. HACCP validation vs. Monitoring: Case Study in Cooling Hot Food. J. Am. Diet. Assoc. 1999, 99, A30. [Google Scholar] [CrossRef] [Scilit]
- Ovca, A.; Škufca, T.; Jevšnik, M. Temperatures and storage conditions in domestic refrigerators—Slovenian scenario. Food Control 2021, 123, 107715. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Stefanou, C.-R.; Szosland-Fałtyn, A.; Bartodziejska, B. Survey of domestic refrigerator storage temperatures in Poland for use as a QMRA tool for exposure assessment. Int. J. Environ. Res. Public Health 2023, 20, 2924. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- European Parliament; Council of the European Union. “On the hygiene of foodstuffs.” Regulation (EC) No. 852/2004 and No 853/2004 of the European Parliament and of the Council of 29 April 2004 on the hygiene of foodstuffs. Off. J. Eur. Union 2004, 139, 1–54. Available online: http://data.europa.eu/eli/reg/2004/852/oj (accessed on 6 August 2026).
- Iulietto, M.F.; Evers, E.G. Modelling and magnitude estimation of cross-contamination in the kitchen for quantitative microbiological risk assessment (QMRA). EFSA J. 2020, 18, e181106. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- JCGM 100:2008; Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement. Joint Committee for Guides in Metrology: Sèvres, France, 2008.
- Lança, M.; Garcia, J.; Gomes, J. Heat Transfer Mechanisms in Refrigerated Spaces: A Comparative Study of Experiments, CFD Predictions and Heat Load Software Accuracy. Energies 2025, 18, 6280. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.