Abstract
Thrust bearings are critical load-bearing components in large vertical hydro-generators, and their operational stability directly affects unit reliability. Conventional thrust bearings face severe challenges including high friction loss, excessive pad temperature and oil-film rupture risk under heavy-load conditions. Electromagnetic load-reduction technology can share a large portion of the axial thrust load, but existing control schemes suffer from slow dynamic response, large thrust fluctuation and insufficient flux-leakage suppression under complex operating conditions. In this work, a 60 t-class vertical electromagnetic load-reduction thrust bearing test platform is designed, and a coordinated control method based on load–magnetic field–current three-loop excitation control and independent flux-leakage compensation is proposed, with oil-film monitoring and branch-output coordination implemented as auxiliary supporting modules whose independent effect was not separately validated. Experimental results show that the proposed method achieves a steady-state load regulation error below 3% over the 20–80% load-reduction range, responds smoothly to step-load changes, and suppresses the external flux leakage by over 60%; meanwhile, the measured oil-film thickness remains above the minimum safe threshold of 30 μm. This work provides experimental verification and engineering design guidance for the application of electromagnetic load-reduction technology in large hydro-generator thrust bearings.