Abstract
To address the degradation of seepage-control linings and structural instability of water-conveyance channels under coupled wetting-drying-freeze-thaw conditions in cold regions, this study investigated rehabilitated channels founded on expansive mudstone in northern Xinjiang. A two-dimensional transient finite-element model with fully coupled seepage, thermal, and mechanical fields was established in COMSOL Multiphysics 6.0 (COMSOL AB, Stockholm, Sweden) and validated against field monitoring data from three canal sections to explore the interactions among seepage evolution, frost-heave deformation, and structural responses over the full operational cycle. Numerical results showed that within five months after impoundment, the groundwater table in the channel foundation rose by approximately 4 m, supplying moisture for winter frost heave. During the four-month freezing period, the maximum frost-heave displacement reached 8 cm, and cyclic tensile stress could trigger geomembrane fatigue cracking mainly within the horizontal zone of 3.5–4.5 m along the channel base. In the subsequent phase after channel shutdown, foundation soil deformation increased to 16 cm, double the magnitude of initial frost heave, and the slope safety factor dropped to 1.305, implying an elevated landslide-failure risk. As a risk-mitigation measure, an acrylic polymer-based coating was adopted for surface seepage-control with favorable water-facing impermeability. Reverse seepage occurred above a backwater pressure of 0.01 MPa for unreinforced coatings, while this threshold can be enhanced by applying reinforcing fabric and interfacial agents. This work quantitatively identifies the progressive failure chain of seepage accumulation, frost heave, geomembrane rupture and slope instability, and evaluates the applicability and limitations of the proposed anti-seepage coating. It further elucidates bypass-seepage and reverse seepage hazards arising at coated-uncoated boundaries under partial surface-sealing schemes. The findings offer theoretical support and practical references for implementing a prevention-oriented strategy integrating surface waterproofing and internal drainage for cold-region water-conveyance infrastructure.
1. Introduction
The seepage-control layer of water-conveyance channels is usually combined with non-woven geotextiles and other materials in forms such as “one fabric, one geomembrane” or “two fabrics, one geomembrane,” and is laid on the channel surface. Such geosynthetic materials are primarily made from polymeric materials. Besides providing seepage control, they also serve reinforcing functions and are an important component of channel slopes. The seepage-control layer, with geomembrane as the main component, experiences a reduction in its seepage-control performance due to long-term free-radical chain reactions [1]. However, the failure of the seepage-control layer in water-conveyance channels located in cold regions is influenced not only by factors such as material properties and construction techniques but also by boundary conditions and complex operating conditions [2,3]. In cold regions, water-conveyance channels often do not retain water during the winter, and there is significant water level fluctuation during the annual operation period of the channel. After entering winter, some channel cross-sections exhibit freeze–thaw sensitivity. A small amount of seepage water can cause frost-heave deformation in the channel, leading to significant damage to the seepage-control layer structure and further exacerbating seepage [4,5]. Each year, the seepage-control layer and the channel bed experience pronounced coupled wetting, drying, freezing, and thawing effects [6,7,8,9,10]. According to on-site project monitoring data (2021) from a main water-conveyance project in northern Xinjiang, a total of 503.4 m2 of lining consisting of prefabricated hexagonal blocks was repaired along the 133 km main channel due to damage caused by seepage and freeze-thaw-related deterioration.
In the analysis of channel slope stability affected by seepage, current studies mostly focus on moisture-induced deformation of the channel foundation or its freeze-thaw effect [11,12,13,14,15,16], while neglecting the failure process of the geomembrane material itself. On the other hand, numerical simulations of channel slope failure generally emphasize single-factor analyses [17,18,19,20], lacking a comprehensive consideration of coupled thermo-hydro-mechanical interactions. In most cases, the seepage-control layer is either assumed to be completely watertight or completely failed, representing two extremes. In practice, seepage may still occur even when the geomembrane’s impermeability remains intact [21,22]. In practical engineering settings, geomembrane seams and local defects such as small perforations lead to an overall permeability coefficient that differs from values obtained under laboratory conditions. Besides these inherent imperfections, cyclic frost-heave-induced tensile damage represents another critical failure mode for field-deployed geomembranes.
Over time, the mechanical behavior and failure timeline of seepage-control layers subjected to typical operational conditions remain critical concerns requiring thorough investigation. Accordingly, this study used a rehabilitated channel in northern Xinjiang as a case study. A coupled transient thermo-hydro-mechanical finite-element model was developed to simulate the full annual operational cycle, including water conveyance, drawdown, shutdown, freezing, and thawing. The main contributions are threefold: (i) the progressive tensile rupture of the geomembrane under cyclic frost-heave loading was identified, with a rupture zone located 3.5–4.5 m from the channel center; (ii) the seepage–frost-heave coupling mechanism was quantified, showing that geomembrane rupture doubles the maximum foundation deformation from ~8 cm to ~16 cm and reduces the slope safety factor to 1.305; and (iii) engineering countermeasures—including flexible polymer coating, optimized drainage, and fatigue-resistant geomembrane selection—were proposed based on the numerical findings. The remainder of this paper is organized as follows.
2. Establishment of the Channel Seepage Control Layer Model
2.1. Geometric Model and Channel Cross-Section
A fully excavated channel section undergoing reconstruction and expansion in northern Xinjiang was selected for detailed analysis (Figure 1). The channel base is composed of expansive mudstone, which exhibits strong frost-heave sensitivity, low water stability, and high volumetric expansion potential. The channel features a slope ratio of 1:2.5, with a structural composition that includes (from top to bottom) a 6 cm precast lining board, a 20 cm mortar cushion layer, a “one fabric, one geomembrane” seepage-control system, and the underlying mudstone foundation. The total channel height is 7 m, with a cross-sectional profile shaped as an arc-bottom trapezoid. Due to the geological characteristics of the site, shallow landslides have previously occurred within this segment, prompting the management unit to reapply the seepage-control layer along the slope for stabilization.
Figure 1.
Typical channel cross-section and impermeable-layer structure.
The model was solved using COMSOL Multiphysics, a multiphysics-coupling finite element analysis software [23,24]. A plane-strain assumption was adopted: soil properties and structural geometry were treated as invariant along the channel’s longitudinal direction. This simplification ignores longitudinal confinement effects, which are further discussed in Section 4.3. A two-dimensional symmetrical cross-section was used to construct the geometric model. This numerical model is derived from a representative field monitoring cross-section of the rehabilitated channel: the total channel height is 7 m, and the water depth used for simulation is 5 m. The operating conditions of the channel include four stages: (i) normal operation (5 m water depth), (ii) water-level drawdown and shutdown, (iii) winter freezing, and (iv) spring thawing.
A convective heat-transfer boundary was applied at the top of the model. During the water-conveyance period, the temperature below the water level was held constant at 15 °C; after shutdown, it followed the ambient temperature boundary, and above the water level, the ambient temperature boundary was used throughout. The ambient temperature was prescribed according to the monthly average temperature in the Altay region [25]. The bottom temperature boundary was set at a constant 2 °C, located 12 m below the channel bottom; the right side was an adiabatic boundary, and the left side a symmetrical boundary.
For seepage, the boundary below the water level was set as a dynamically changing pore-pressure boundary according to operating conditions, while above the water level, it was a free-outflow boundary. The left side was a symmetrical water-pressure boundary, the right side a no-flow boundary, and the bottom an infiltration boundary.
For structural mechanics, normal displacement constraints were applied at the bottom and right side, with symmetrical constraints on the left side. A water-pressure load was applied below the water level inside the channel, varying dynamically with water level.
The entire calculation was transient, with coupling of the seepage, heat-transfer, and deformation fields. The geometric model was discretized with quadrilateral elements; the finite element mesh, boundary settings, and time-varying environmental boundaries are shown in Figure 2.
Figure 2.
Geometric model and applied boundary conditions. The two-dimensional symmetric cross-section shows the finite-element mesh and layered strata; the red line on the slope crest denotes the ambient temperature boundary (boundary A), where a time-varying temperature is prescribed, and the blue line denotes the water-depth boundary (boundary B). (a) Temperature above and below the water surface (°C) over time (d); (b) water level (m) over time (d).
In the numerical model, the lining and geomembrane were treated as linear elastic materials, and seepage through these layers was described by Darcy’s law. In practice, the lining consists of precast concrete slabs jointed by mortar, which accommodates deformation through discontinuities at the joints; to reduce computational cost, the joint details and concrete plasticity were neglected, and the entire lining was represented as an equivalent continuous layer. The equivalent mechanical and hydraulic parameters assigned to this layer, and those of the underlying one-fabric, one-geomembrane layer, are given in Section 2.4.
2.2. Mathematical Formulation of the Coupled Thermo-Hydro-Mechanical Model
2.2.1. Variably Saturated Seepage Model
The seepage process in the channel foundation was described using the variably saturated seepage equation. The mass conservation equation of water is expressed as:
where θ is the volumetric water content, t is time, q is the Darcy seepage velocity, and Qw is the source or sink term.
The Darcy velocity is expressed as:
where K(h) is the unsaturated hydraulic conductivity, h is the pressure head, and z is the elevation head.
q = −K(h)∇(h + z)
The relationship among pressure head, saturation, and hydraulic conductivity was described using the van Genuchten model:
where Se is the effective saturation, θs is the saturated volumetric water content, θr is the residual volumetric water content, Ks is the saturated hydraulic conductivity, and α, n, m, and l are empirical parameters.
For the lining and geomembrane layers, seepage was simplified using Darcy’s law with equivalent permeability coefficients. This equivalent-permeability approach accounts for the combined effects of material-matrix permeability, construction seams and minor fabrication defects under field-scale conditions. The local damaged zone of the geomembrane was represented by an increased permeability coefficient, which reflects the reduction in seepage-control capacity after tensile damage.
2.2.2. Heat Transfer and Freezing–Thawing Model
The transient temperature field was governed by the heat conduction equation:
where T is temperature, ρ is density, Ceff is the effective heat capacity, λeff is the effective thermal conductivity, and QT is the heat source term.
To describe the freezing–thawing process of pore water, the latent heat effect was considered using the apparent heat capacity method:
where C0 is the heat capacity without phase change, Lf is the latent heat of fusion, and θi is the volumetric ice content. When the temperature decreases below the freezing point, part of the pore water freezes and contributes to frost-heave deformation.
2.2.3. Mechanical Deformation Model
The mechanical equilibrium equation of the lining, geomembrane, and foundation soil is written as:
where σ is the total stress tensor and g is gravitational acceleration.
The strain–displacement relationship is:
where ε is the strain tensor and u is the displacement vector.
The effective stress principle was introduced to describe the influence of pore water pressure on deformation and stability:
where σ′ is the effective stress tensor, p is pore water pressure, αB is Biot’s coefficient, and I is the identity tensor.
The lining and geomembrane were treated as linear elastic materials:
where D is the elastic stiffness matrix.
The foundation soil was described using an elastoplastic constitutive model with the Mohr–Coulomb failure criterion:
where τf is shear strength, c is cohesion, is effective normal stress, and φ is the internal friction angle.
2.2.4. Frost-Heave Strain and Geomembrane Damage Representation
The total strain of the freezing foundation soil was decomposed into elastic strain, plastic strain, and frost-heave strain:
where εe, εp, and εfh are the elastic strain, plastic strain, and frost-heave strain, respectively.
The frost-heave strain was expressed as:
where βf is the frost-heave coefficient and θi is the volumetric ice content. The frost-heave coefficient βf was set to 0.42 for the expansive mudstone foundation, which was derived from regional geotechnical laboratory tests on local seasonally frozen expansive mudstone in northern Xinjiang (unpublished project test data). This empirical coefficient links volumetric ice content to frost-heave strain under open-system moisture supply conditions.
The tensile response of the geomembrane was evaluated according to the calculated tensile force. The geomembrane tensile strength at break was taken as 43 kN/m (longitudinal), as specified by the manufacturer and verified by laboratory tests (GB/T 1040.3-2006) [26] A threshold-based damage criterion was adopted: once the tensile force reached or exceeded the tensile strength at break (43 kN/m), the zone was marked as fully ruptured. This represents the ultimate failure state. It is acknowledged that fatigue damage may initiate at lower stress levels under repeated freeze–thaw cycles [27,28]; however, the present study adopts the 43 kN/m threshold as an upper-bound (conservative) estimate of the damage state. Consequently, the predicted damage zone and subsequent permeability increase represent a worst-case scenario for the second operational year, rather than a prediction of the actual damage initiation time. This conservative simplification is justified for the purpose of assessing the maximum potential impact of geomembrane rupture on slope stability. More refined fatigue-based damage evolution models are recommended for future work.
For the fully ruptured zone defined above, the seepage-control capacity was reduced by increasing its local permeability coefficient from 1 × 10−10 m/s (intact) to 1 × 10−8 m/s (fully ruptured), representing a two-order-of-magnitude increase consistent with the formation of tensile cracks and seam openings. After completing the initial simulation described in Section 3.2 to locate the region of peak tensile force, the ruptured zone was set as a 1.0 m-wide strip centered on this high-tension horizontal band, which spans 3.5 m–4.5 m from the channel-bottom center. Partial damage was not considered; once the threshold was exceeded, the entire affected zone was assigned the fully ruptured permeability coefficient.
2.2.5. Slope Stability Analysis
The slope stability of the channel foundation was evaluated using the strength reduction method based on effective stress. The shear strength parameters were reduced as follows:
In the present analysis, shear-strength parameters (cohesion and internal-friction angle) were kept constant irrespective of soil saturation and ice-content conditions. The variation in shear strength with saturation is acknowledged as a study limitation and is recommended for future investigation. The two-dimensional plane-strain assumption may either overestimate or underestimate the safety factor relative to a full 3D analysis, as longitudinal confinement effects from the channel embankment are neglected. It should be noted that the calculated slope safety factor is susceptible to variations in shear-strength parameters, saturation threshold and drainage conditions. In particular, the internal-friction angle and drainage configuration exert prominent influences on stability outcomes. A comprehensive quantitative sensitivity assessment of these influencing factors is suggested for future research.
In this strength-reduction finite-element analysis, penetration of the plastic-strain zone across the potential slip surface was adopted as the critical failure criterion for judging the limit equilibrium state.
2.3. Initial and Boundary Conditions
The channel operation process was divided into four stages: normal water-conveyance, water-level drawdown and shutdown, low-temperature freezing, and temperature-rise thawing. During the normal water-conveyance period, the water depth was set to 5 m.
For the seepage field, the channel surface below the water level was assigned a time-dependent water pressure boundary:
where ρw is the density of water, g is gravitational acceleration, H(t) is the time-dependent water level, and y is the vertical coordinate.
p = ρwg[H(t) − y](y ≤ H(t))
Above the water level, a free-outflow boundary was adopted:
p = 0
The bottom boundary was set as an infiltration boundary with a prescribed flux of 5 × 10−8 m/s, estimated from field pumping tests at the site:
where n is the outward normal vector and qb is the prescribed infiltration flux.
−q ⋅ n = qb
The symmetry and no-flow boundaries were expressed as:
q ⋅ n = 0
For the thermal field, the exposed channel surface was assigned a convective heat-transfer boundary with a convective coefficient of 15 W/(m2·K), estimated from empirical correlations for atmospheric heat exchange over exposed concrete lining surfaces:
where hc is the convective heat-transfer coefficient and Tair(t) is the time-dependent ambient temperature.
−λ∇T ⋅ n = hc[Tair(t) − T]
During the water-conveyance period, the temperature below the water level was set to 15 °C:
T = 15 °C
The bottom temperature boundary was set to 2 °C at 12 m below the channel bottom:
T = 2 °C
The adiabatic boundary was expressed as:
−λ∇T ⋅ n = 0
For the mechanical field, normal displacement constraints were applied at the bottom and lateral boundaries:
u ⋅ n = 0
The water pressure acting on the lining surface below the water level was applied as an external load:
where t is the boundary traction.
t = −pn
The initial conditions were defined based on field measurements conducted before the channel was put into operation. The initial pore water pressure distribution corresponded to a hydrostatic condition with the groundwater table at 8 m below the channel bottom. The initial temperature field was set to a linear distribution from 15 °C at the surface to 2 °C at 12 m depth, consistent with pre-operation monitoring data:
where T0 and p0 are the initial temperature and pore water pressure distributions, respectively.
T(x,y,0) = T0(x,y)
p(x,y,0) = p0(x,y)
u(x,y,0) = 0
2.4. Material Parameters and Numerical Implementation
The material parameters used in the numerical model are summarized in Table 1 and Table 2. The basic geotechnical parameters of the foundation—density, elastic modulus, cohesion, internal friction angle, and saturated permeability—were obtained from laboratory tests following SL 237-1999 [29]. Poisson’s ratio and porosity were indirectly derived from these test data, while the van Genuchten parameters n and α were fitted from pressure-plate, soil-water-retention tests. The thermal conductivity, isobaric heat capacity, and Biot’s coefficient were assigned based on typical values for sedimentary mudstone [30,31]. The equivalent elastic modulus and permeability coefficient of the one-fabric, one-geomembrane layer were measured on specimens recovered from the rehabilitated channel. The variably saturated seepage behavior of the foundation soil was described using the Richards equation [32].
Table 1.
Physical and mechanical parameters of the channel bed.
Table 2.
Physical and mechanical parameters of geomembrane.
The governing equations described above were solved using the finite-element method in COMSOL Multiphysics. The seepage field, temperature field, and deformation field were solved under transient conditions using a segregated (staggered) coupling approach: at each time step, the seepage field was solved first, followed by the temperature field, and then the mechanical field. The coupling variables were transferred among different physical fields after each field solution within the same time step. The seepage field provided pore pressure and saturation to the mechanical field. The temperature field provided temperature and ice content for the frost-heave strain calculation. The mechanical field provided tensile stress and deformation information for identifying the potential geomembrane damage zone. After damage occurred, the local permeability coefficient of the geomembrane was increased to simulate the deterioration of its seepage-control capacity.
Quadrilateral elements were used for the two-dimensional cross-section model. The mesh consisted of approximately 8500 elements and 26,000 degrees of freedom. Mesh refinement was applied near the channel lining, geomembrane, mortar cushion layer, and foundation interface, where large hydraulic gradients, temperature gradients, and stress concentrations were expected. Mesh refinement aimed to capture sharp gradients and stress concentrations at material interfaces without excessive computational overhead. The minimum element size in the refined zones was 0.02 m, and the maximum element size in the far field was 0.5 m. A mesh convergence study was performed by comparing results from three mesh levels (coarse: ~4000 elements; medium: ~8500 elements; fine: ~16,000 elements); the maximum frost-heave displacement differed by less than 2% between the medium and fine meshes, confirming convergence. An adaptive time-stepping strategy was employed with an initial time step of 1 h, a minimum time step of 0.1 h, and a maximum time step of 24 h. The relative tolerance for all physics was set to 0.001, and the absolute tolerance was set to 0.0001. The entire simulation process corresponded to the annual cycle of water conveyance, water-level drawdown, shutdown, freezing, and thawing, with a total simulated duration of two annual cycles.
The numerical model was then employed to simulate the full annual operational cycle of the cold-region channel, including water conveyance, water-level drawdown, shutdown, freezing, and thawing phases. Model validation against field-monitoring datasets is provided in Section 3.3.
3. Simulation Results and Analysis
3.1. Seepage, Temperature, and Deformation Fields During the First Operational Cycle
First, changes in the seepage field during the initial operational period, when the seepage-control layer remained intact, were examined. The simulation covered four sequential operational phases: normal water conveyance (water depth 5 m), water-level drawdown and shutdown, low-temperature freezing, and spring thawing, representing a complete annual cycle of 365 days; Figure 3 presents the seepage field during water conveyance and shutdown (Figure 3a–c) and the temperature and deformation fields during freezing (Figure 3d); the contour plots are mirrored, with hydraulic head (m) as the indicator in Figure 3a–c. During the first month of operation (Figure 3a), the saturated zone was confined to the gravel cushion layer at the channel bottom, with only limited accumulation of seepage water. The groundwater level (dark blue area) underwent a slight rise, remaining within the depth range of −8 to −10 m, indicating controlled seepage without adversely compromising structural stability.
Figure 3.
Changes in seepage field during the first operation period of the channel. (a) Seepage field after one month of water flow; (b) Seepage field after five months of water flow; (c) Seepage field after water shutoff; (d) Temperature and deformation characteristics of the channel cross-section in winter. Red arrows in (a–c) indicate seepage velocity vectors; Red arrows in (d) indicate displacement vectors. Note: Saturation values exceed 1.0 due to volumetric ice content during freezing.
When the operational period extended to five months (Figure 3b), seepage water accumulated toward the underlying impermeable mudstone foundation, raising the groundwater level by 4 m. The saturated zone expanded beyond the gravel cushion, extending into the lining layer and across the entire channel bottom. Prolonged water retention at the interface between the lining and the foundation soil might weaken the bonding strength, creating potential hazards.
During the shutdown period (Figure 3c), although some seepage water overflowed, the remainder continued to infiltrate downward, maintaining a high groundwater level and storing moisture reserves for winter frost heave. The channel exhibited slight overall settlement; however, the geomembrane remained unstretched and intact, preserving the channel’s overall structural integrity.
When temperatures dropped below 0 °C after water withdrawal (Figure 3d), the channel foundation reached a maximum freezing depth of 2 m. As shown in the temperature and deformation fields (Figure 3d), over the four-month freezing period, the red zones in the deformation field indicated a maximum displacement of approximately 7 cm–8 cm, with the channel contracting inward. Due to dual constraints from the foundation soil and upper lining structure, the middle-lower part of the lining experienced the highest frost-heave pressure despite limited deformation magnitude, consistent with frost-heave characteristics of arc-bottom trapezoidal channels [38]. The temperature field exhibited a three-zone structure: a frozen layer extending from the channel surface to the maximum frost depth, a transition zone with temperatures fluctuating around 0 °C, and an unfrozen zone below where the groundwater remained unfrozen. As the frost depth increased, the frost-heave deformation gradually propagated downward, while the surface frost-heave stress and the tensile force on the geomembrane correspondingly decreased. This temperature distribution controlled the depth and magnitude of frost heave by governing the phase change in pore water into ice, which was the primary driver of volumetric expansion in the foundation soil.
The full cycle demonstrates a sequential mechanism: “seepage accumulation → saturation expansion → frost-heave activation → deformation intensification”. Seepage serves as the fundamental cause, low temperatures trigger frost heave, and structural constraints govern deformation distribution.
3.2. Frost-Heave-Induced Geomembrane Rupture and Post-Rupture Slope Instability
The geomembrane beneath the concrete lining was extracted for tensile analysis. The initial cyclic simulation for the intact channel structure showed that, after three months of freezing, the tensile force in the geomembrane approached its rupture strength of 43 kN/m (Table 2). The simulation revealed that the peak tensile stress occurred within a horizontal range of 3.5–4.5 m from the center of the channel base. As the frost front advanced downward, the surface frost-heave stress and the corresponding tensile force in the geomembrane both decreased. Throughout the freezing period, the geomembrane experienced repeated cycles of tensile loading and unloading. Such cyclic fluctuations, particularly in the region of maximum tension, can induce fatigue crack initiation and propagation [39,40], thereby preferentially damaging the geomembrane and ultimately exacerbating leakage during the subsequent water-stoppage phase.
Based on the high-tension zone identified in Section 2.2.4, the equivalent permeability approach described above was applied to simulate geomembrane rupture. A full annual cycle of the channel’s second-year operation—including water conveyance, water drawdown, and winter dewatering—was then computed to investigate the dynamic seepage, saturation, and deformation responses of the foundation induced by the damage, and to support slope-instability risk assessment (Figure 4).
Figure 4.
Seepage and deformation fields of the channel after geomembrane damage (red arrows in the left panels indicate displacement vectors). (a) One month after geomembrane damage; (b) Five months after geomembrane Damage; (c) During the water shutdown period after geomembrane damage.
Seepage field characteristics: In Figure 4a (one month after damage), the deformation field shows that the maximum displacement (red zone, ~12 cm) was concentrated at the slope crest, while the deep foundation remained in the low-deformation range (dark blue, <2 cm). The saturation field reveals that the channel bottom center was highly saturated (pink, saturation ≈ 0.9), whereas the slope surface remained at moderate saturation (green to yellow, 0.5–0.7) and the top platforms were relatively unsaturated (dark blue, <0.3). The red arrows indicate the direction and magnitude of seepage velocity (arrow length is proportional to flow velocity): a concentrated seepage pathway formed at the damaged section, where flow velocity increased markedly. Seepage propagated from the damaged zone into the deeper foundation and gradually extended toward the toes of both side slopes, establishing a hydraulic connection that facilitated the subsequent expansion of the saturation zone.
Evolution of saturation distribution: In Figure 4b (five months after damage), the deformation field shows that the maximum displacement increased to 16 cm (red zone at the slope crest), far exceeding the pure frost-heave limit of 8 cm; the high-deformation zone (yellow to red, >8 cm) had expanded downward to cover the entire upper and middle slope. Taking a saturation value of 0.9 as the threshold for high-water-content risk, the saturation field shows that the high-saturation zone (pink, ≥0.9)—initially confined to the channel bottom—had progressively expanded toward the mid-depth of the foundation and beneath both slope toes. This evolution directly reflects the migration and accumulation of moisture within the soil. The formation of saturated zones beneath the slope toes further weakened the soil strength and created preconditions for potential sliding.
Channel-foundation deformation and instability mechanism: In Figure 4c (during the water-shutdown period), the deformation field shows that the maximum displacement remained elevated at approximately 14 cm (red zone at the slope crest), with the high-deformation zone (yellow to red, >8 cm) concentrated on the upper and middle slope; the slope toe exhibited moderate deformation (green, 6–8 cm). The saturation field reveals that the channel bottom, both slope toes, and the deep foundation remained highly saturated (pink, ≥0.9) even after shutdown, indicating persistent moisture retention in the foundation. This indicates that the deformation mechanism had shifted from frost-heave dominance to a seepage-driven, high-saturation mode. The strength of the highly saturated soil was significantly reduced, intensifying plastic deformation. Even after channel shutdown, the foundation continued to deform inward, with particularly pronounced deformation at the slope toe, strongly correlated with the distribution of the saturation zone. Prolonged saturation and the consequent strength loss made the soil beneath the slope toe the weakest zone; under the persistent inward deformation trend, this area was highly prone to initiating overall slope failure.
Stability analysis: It should be noted that the displacement field (Figure 4) and the plastic strain field (Figure 5) exhibit distinct distributions: the maximum displacement occurred at the slope crest due to the free-surface boundary condition, whereas the maximum plastic strain was concentrated at the channel bottom center due to stress concentration. As shown in Figure 5, the plastic strain field (range: 1.0–2.4 × 10−3) reveals that the maximum plastic strain (dark red, 2.4 × 10−3) was concentrated at the channel bottom center, while high-plastic-strain zones (orange to red, 2.0–2.2 × 10−3) formed two arcuate bands initiating from above the slope toes and extending toward the channel bottom, defining a “steep-above, gentle-below” slip surface. The deep foundation and top platforms remained in the elastic range (dark blue, ~1.0 × 10−3). Mechanistically, the slope toe represented the weakest zone in terms of shear strength, owing to prolonged saturation and softening, and thus served as the initiation point of the slip surface, whereas the channel bottom center represented the zone of maximum irreversible deformation owing to stress concentration, corresponding to the deepest point of the slip surface. The formation of the slip surface was controlled by both seepage and unloading: water accumulation in the foundation softened the soil and reduced its shear strength, providing the mechanical conditions for slip-surface initiation; meanwhile, the unloading effect caused by internal water seepage during the withdrawal period disrupted the original stress balance, further promoting deep expansion of the slip surface and ultimately leading to inward slope failure. The strength-reduction analysis yielded a safety factor of F = 1.305, indicating that the channel foundation was in a critically stable state with limited anti-sliding capacity.
Figure 5.
Stability analysis results of the channel during the no-water period (safety factor F = 1.305). x: Horizontal distance (m); y: Elevation (m); z: Longitudinal direction (m).
3.3. Field Validation of Numerical Results
To validate the numerical model predictions, field monitoring data were collected from ten automated observation sections established along the Beijiang Water Supply Main channel. Among these, three representative sections were selected for detailed analysis: Section 48 with a full-section coating, Section 49 as the uncoated control, and Section 105 with partial coating. Each monitoring section was instrumented with vibrating-wire piezometers installed behind the geomembrane and at depths of 2 m, 4 m, and 5 m below the channel bed (sensor placement varied slightly by section according to the actual lining structure), and with integrated displacement sensors embedded beneath the geomembrane to measure slope-normal deformation. Data were recorded at 1 h intervals; the monitoring records presented herein cover the period from April 2021 to May 2022.
At Section 48, where full-section acrylic polymer coating was applied, the monitoring data showed that the pore water pressure behind the geomembrane decreased significantly after treatment: the peak pore water pressure behind the geomembrane remained consistently low throughout the monitoring period, with peak values not exceeding approximately 5 kPa–8 kPa and staying close to zero or slightly negative (Figure 6), although the deep-layer sensors (4 m below the channel bed) still recorded marked seasonal fluctuations of up to approximately 80 kPa (Figure 6). The channel surface displacement during shutdown remained small, with a maximum absolute value of approximately 1.8 mm (Figure 7). In contrast, at the uncoated comparison Section 49, the pore water pressure behind the geomembrane remained high during the water-conveyance period, with peak values reaching 30–35 kPa at the slope-arc positions (Figure 8). Significant surface displacement was observed during shutdown: the upper- and lower-mid slope positions accumulated inward displacements of 2.5–2.7 mm, while the embankment crest exhibited an upward heave of up to 3.5 mm (Figure 9). These field observations are consistent with the numerical prediction that full-section coating maintains a negative seepage pressure and an unsaturated state in the channel base layer.
Figure 6.
Pore water pressure at different monitoring points on the channel cross-section after anti-seepage coating treatment.
Figure 7.
Displacement at different monitoring points on the channel cross-section after anti-seepage coating treatment.
Figure 8.
Pore water pressure at different monitoring points on the channel cross-section without anti-seepage coating treatment.
Figure 9.
Displacement at different monitoring points on the channel cross-section without anti-seepage coating treatment.
At Section 105, where only partial surface coating was applied (the downstream section was coated while the upstream section remained uncoated), the monitoring data revealed distinct responses between the two subsections. In the coated subsection, the pressure head behind the geomembrane at the channel bed reached approximately 1.05 m during water conveyance, while the mid-slope and raised-section positions maintained negative pressure heads of about −0.2 m (Figure 10). In the uncoated subsection, the pressure head behind the geomembrane at the channel bed was substantially higher, reaching 4.3 m and remaining stable throughout the monitoring period (Figure 11), more than four times the value in the coated subsection—indicating persistent and intensifying seepage. This contrast is consistent with the numerical prediction of bypass seepage in partially coated sections. The 2022 water-level monitoring data for the coated subsection and the uncoated subsection of Section 105 are presented in Figure 10 and Figure 11, respectively. Furthermore, a field investigation at Section 105 confirmed the occurrence of reverse seepage: seepage water was observed at the slope toe behind the coated section, with a measured flow rate of approximately 0.5 L/s, and the water level at the seepage point was 4.7 m below the channel water surface. Drilling investigations confirmed that the saturated zone extended 2.7 m below the channel bed at the mid-slope and that bypass seepage had developed along the channel embankment from the uncoated upstream section. These field observations provide direct validation of the bypass seepage and reverse-seepage mechanisms identified in this study. A three-dimensional numerical analysis of these phenomena is further presented in Section 5.2.
Figure 10.
Water level variation with time at different monitoring points on the channel cross-section in the anti-seepage coated Section (2022 water-conveyance period).
Figure 11.
Water level variation with time at different monitoring points on the channel cross-section in the uncoated section (2022 water-conveyance period).
It should be emphasized that the large-magnitude displacement (8 cm frost heave, 16 cm post-shutdown deformation) and slope safety factor F = 1.305 presented in this paper are outputs from numerical simulation. Direct field measurements of such large foundation deformation and slope safety factor were not available for this canal segment. Field monitoring data mainly serve to validate the changing trend of pore-water pressure and the occurrence of bypass seepage under different coating schemes. The evidence supporting the main results of this study is summarized in Table 3.
Table 3.
Evidence-mapping table.
3.4. Summary of Failure Process
Based on this, the failure process of the seepage-control layer in cold-region, water- conveyance channels under the coupling effects of “wetting-drying-freezing-thawing” can be summarized as follows: (i) The permeability coefficients of the channel lining and seepage-control layer were relatively low, with the geomembrane having an even lower coefficient. However, after the operational period, some seepage occurred in the channel base, leaking downward through the mortar cushion layer, which raised the groundwater level in the channel base. This process provided a source of water for frost heave during winter, although the seepage-control layer remained intact at this stage. (ii) In winter, under low temperatures, the frost-heave deformation of the soil exerted frost-heave forces on the lining structure. The underlying geomembrane underwent tensile deformation, and once it exceeded its tensile strength of 43 kN/m, the geomembrane ruptured. (iii) In the subsequent operational period, a saturated region rapidly formed in the channel base at the location of geomembrane damage. After the water was stopped, the channel base deformed, resulting in greater deformation than frost heave.
A quantitative comparison of the key results reveals that geomembrane rupture triggers a twofold increase in maximum foundation deformation (from 8 cm to 16 cm) and a shift in the dominant deformation mechanism from frost-heave-driven to seepage-driven. The strength-reduction analysis yielded F = 1.305 under the post-rupture, no-water condition. This value barely exceeds the minimum required safety factor of 1.30 for a grade-1 (important) water-conveyance channel slope under normal operating conditions specified in SL 386-2007 [41], and remains below the more conservative threshold of 1.35 adopted for the same expansive-mudstone canal in northern Xinjiang [22]. The available margin is therefore limited against external disturbances such as rapid water-level drawdown or rainfall infiltration.
4. Discussion
4.1. Failure Mechanism and Engineering Countermeasures
The numerical results reveal a sequential failure mechanism comprising seepage accumulation, frost-heave activation, geomembrane tensile rupture, and slope instability. This chain of processes is initiated by the gradual rise in the groundwater table (approximately 4 m over five months of operation), which supplies moisture for winter frost heave. During the four-month freezing period, frost-heave deformation reaches approximately 7 cm–8 cm, and the resulting cyclic tensile stress causes fatigue cracking in the geomembrane within a horizontal range of 3.5–4.5 m from the channel bottom center. Once the geomembrane is damaged, seepage accelerates and the foundation soil becomes highly saturated, leading to a maximum deformation of 16 cm at five months after damage (approximately 14 cm during the subsequent shutdown period)—twice the pure frost-heave value—and a safety factor of 1.305. This mechanism indicates that the conventional assumption of a permanently intact geomembrane is unsafe for cold-region channels on expansive mudstone foundations, and that seepage control must address not only the initial impermeability but also the progressive degradation under coupled wetting-drying-freezing-thawing cycles. From an engineering perspective, three measures are recommended: (i) applying a full-section acrylic polymer coating to maintain negative pore water pressure behind the geomembrane, as validated by field monitoring at Section 48; (ii) optimizing the longitudinal and transverse drainage system to reduce internal water pressure during shutdown; and (iii) selecting geomembrane materials with improved fatigue resistance under cyclic tensile loading to extend the service life of the seepage-control layer.
4.2. Comparison with Previous Studies
The predicted frost-heave displacement of approximately 7–8 cm is consistent with values reported for seasonally frozen channels with expansive clay foundations. Teng et al. [42] reported a maximum frost-heave displacement of approximately 2.3 cm for a model-scale channel under controlled laboratory conditions; applying a geometric scale factor of approximately 1:3.5 (consistent with typical channel model-prototype ratios), this value scales to approximately 7–9 cm for a prototype channel of similar geometry, which brackets the present prediction. For channels incorporating sand-gravel replacement as a frost-heave mitigation measure, field monitoring in the Jingdian Irrigation District has reported reduced frost-heave displacements of 2–3 cm [43], confirming that replacement layers effectively limit frost heave by reducing the moisture availability and frost susceptibility of the foundation soil—a finding that supports the present conclusion that seepage accumulation is the primary driver of frost-heave deformation. The predicted groundwater level rise of 4 m over five months is also consistent with field observations from the Beijiang Water Supply Main channel, where site piezometer monitoring showed rises of 3–5 m during the initial operational period after channel repair. Unlike previous studies that focused on either seepage or frost heave as isolated factors, the present work demonstrates their coupled interaction and the resulting progressive degradation of the geomembrane, providing a more complete picture of the failure process in cold-region channels.
4.3. Limitations and Future Work
The present study adopts a two-dimensional (2D) plane-strain formulation, a widely used simplification in channel seepage and stability analysis [44,45,46]. Three limitations should be acknowledged. First, the plane-strain assumption neglects the longitudinal confinement of the channel embankment, which may affect the predicted stress distribution and safety factor; 3D analyses generally yield higher safety factors due to longitudinal arching [47]. Second, the predicted geomembrane damage zone (3.5–4.5 m across the section) may exhibit significant longitudinal variation due to non-uniform soil properties and construction defects, requiring 3D analysis to capture the spatial extent and connectivity of damage [48]. Third, the longitudinal drainage pipes and transverse connections were represented through equivalent boundary conditions, which may not fully capture 3D flow convergence toward drainage outlets. Despite these limitations, the 2D formulation is justified because the analyzed channel segment is relatively uniform longitudinally, the primary failure mechanisms are dominated by cross-sectional processes, and a fully coupled 3D transient thermo-hydro-mechanical analysis with damage evolution would be computationally prohibitive. Future work should employ 3D analysis to investigate the longitudinal variation in damage zones and the performance of localized coating systems.
In the present study, comprehensive quantitative parameter-sensitivity analyses for hydraulic conductivity, frost-heave coefficient, geomembrane stiffness, boundary temperature, as well as slope-safety-factor sensitivity with respect to cohesion, friction angle, saturation threshold and drainage condition were not performed. Such sensitivity assessments would help to quantify how uncertainties in soil and material parameters propagate to predicted frost-heave displacement, geomembrane tension, and slope safety factor, and should be prioritized in future investigations.
5. Measures for Improving Seepage Prevention Capability
To address the issue of channel leakage, current solutions adopted in large-scale water diversion and transfer projects primarily include “channel bed replacement and the installation of longitudinal and transverse drainage systems”. Although channel bed replacement can effectively reduce frost-heave deformation by removing frost-susceptible soil, it involves high construction costs and significant engineering disturbance, making it impractical for long-distance channel renovation. Among these, the installation of longitudinal and transverse drainage systems can effectively alleviate channel leakage, and this method has been applied in the Beijiang Water Supply Main channel [49,50]. However, this approach still has two potential drawbacks. First, the efficiency of leakage water extraction may be insufficient. In some sections, the leakage volume during operation is relatively large, and the limited power of the sump pumps causes the seepage inflow rate to exceed the pumping rate. Second, the drainage system faces operational challenges. As shown in Figure 12, the system comprises a collection sump equipped with electric pumps and longitudinal drainage pipes (Figure 12a), and the recharge rate increases nonlinearly with the water level difference between the collection well and the channel (Figure 12b). Field installations have been deployed at stations such as K23 + 500 (Figure 12c); however, seepage and piping phenomena have been observed at the channel bed (Figure 12d), indicating that drainage alone may be insufficient to control seepage in severe leakage sections. Such situations frequently occur in practice, posing significant risks to the stability and safety of the channel embankments, particularly during the water level decline phase in the water stoppage period.
Figure 12.
Drainage system for channel seepage control. (a) Schematic diagram of the drainage system, including the collection sump, electric pump, longitudinal drainage, control panel, and power cable; (b) relationship between flow rate and water level difference between the collection well and the channel (recharge rate); (c) photograph of the on-site drainage well at chainage K23 + 500; (d) photograph of the drainage outlet inside the collection sump.
To overcome the aforementioned limitations, this study adopts the principle of “combining seepage prevention and drainage”: drainage focuses on the seepage water that has already infiltrated the channel foundation, while seepage prevention aims to reduce infiltration at the source. Accordingly, a flexible surface coating material is proposed to enhance seepage control in channel sections with severe local leakage, thereby mitigating various instability problems induced by channel seepage.
5.1. Selection and Characteristics of the Coating Material
According to the numerical simulation results presented in Section 3, under the coupled wetting-drying-freezing-thawing cycles, the channel lining and underlying geomembrane are subjected to significant frost-heave force and seepage pressure. During the period of maximum frost depth, the pure frost-heave deformation of the channel foundation reaches approximately 7–8 cm. When considering the coupling effect of seepage-induced softening, the total deformation can increase to 16 cm. For a typical lining slab length of several meters, this deformation corresponds to a tensile strain far exceeding the ultimate tensile strain of the concrete lining (0.01–0.02%), which consequently triggers cracking of the lining slabs and tensile rupture of the geomembrane [51]. Under such service conditions, the acrylic polymer coating is required to possess sufficient deformation compatibility. When tensile cracks form in the concrete lining, the flexible coating can deform compatibly with the substrate through self-elongation, realizing crack-bridging performance and maintaining the continuity of the anti-seepage capacity [52,53].
Among various flexible anti-seepage materials, acrylic polymer coatings exhibit favorable compatibility with cement-based lining substrates. Benefiting from low cost (as demonstrated by the economic analysis in Section 5.3.3) and environmental friendliness, such materials are more suitable for large-scale engineering applications in cold-region channels [54,55]. This two-component material consists of a polymer acrylate emulsion (Component A) and solid cement-based powder (Component B). Component A is mainly composed of monomers, water, emulsifiers, initiators, dispersants and other additives. Its film-forming process follows the free-radical emulsion-polymerization mechanism: free radicals diffuse through the aqueous phase into micelles and trigger continuous nucleation and polymerization. With the increasing nucleation rate, the number of micelles in the system gradually decreases. Eventually, only stable latex particles remain without monomer droplets, forming a dense film adhered to the substrate [56]. Component B is a multi-component inorganic cement-based filler. Its mineral phases have been identified by X-ray diffraction (XRD) analysis (see Section 5.3.1 for details), and it mainly acts as a structural reinforcing filler. This material has been adopted for seepage remediation of the Northern Xinjiang Water Supply Main Channel, as illustrated in Figure 13.
Figure 13.
Field application of the two-component acrylic polymer coating on the rehabilitated channel lining.
This two-component material undergoes dual curing mechanisms: evaporation-induced curing and chemical reaction-based curing. After mixing polymer emulsion with cement powder, partial water evaporates from the emulsion, driving polymer particles to coalesce into a continuous elastic film. Meanwhile, the cement-based powder consumes residual water and undergoes hydration reactions, producing calcium hydroxide Ca(OH)2, ettringite, and calcium silicate hydrate (C-S-H) gels. Organic polymer chains and inorganic hydration products thereafter form an interpenetrating polymer network (IPN) via ionic bonding, as expressed by the following equation:
nP–COO− + Mn+ ⟹ (P − COO)nMe
The IPN structure integrates high flexibility and crack-bridging capacity from organic phases with high strength and anti-aging performance from inorganic phases, endowing the coating with unique stiffness-flexibility coupling properties [57]. The waterproofing mechanism of this coating belongs to the barrier-film type. Although the intermolecular gaps inside polymer solids are on the order of tens of nanometers, considerably larger than the diameter of a single water molecule (~0.4 nm), liquid water molecules assemble into large hydrogen-bonded molecular clusters that cannot readily penetrate these nanoscale voids [58]. Furthermore, active groups in polymers can cross-link with Ca2+ and Al3+ released during cement hydration to form chemical bridge-bonds, restraining microcrack initiation and further improving the compactness and waterproof performance of the coating [59].
5.2. Comparison and Validation of Waterproofing Performance
A numerical simulation of the seepage field, deformation field, and stability of the channel was conducted after the application of the impermeable coating. The calculation model was identical to that used in the preceding analysis, except that the permeability coefficient of the impermeable coating was set much lower than that of the lining, and the channel height was increased to 7 m.
Figure 14 presents the channel seepage field during the highest water level in the operational period, corresponding to the condition with the highest leakage risk. The results indicate that after the application of the surface coating, the leakage pathways caused by lining joints and geomembrane damage were effectively mitigated. The seepage pressure in the upper layer of the channel bed was negative (below atmospheric pressure), indicating an unsaturated state, and the seepage rate per unit width was negligible (less than 1 × 10−8 m2/s).
Figure 14.
Seepage field of the channel at the maximum operating water level (arrows indicate seepage velocity vectors).
During the maximum freeze-depth period (Figure 15), the channel’s frost-heave deformation field was examined. The primary deformation during the freeze period was concentrated at the slope top, with a maximum displacement of approximately 0.10–0.12 m. The soil near the channel lining remained unsaturated, and the ice volume in the pores was less than the total pore volume. Consequently, the deformation was dominated by thermally induced volume contraction rather than upward frost heave, resulting in primarily downward displacement of the channel. The lining structure and geomembrane were in compression without tensile stress, thereby protecting the geomembrane from further tensile damage.
Figure 15.
Deformation field of the channel during the maximum frost-depth period (arrows indicate displacement vectors).
This scenario represents the most ideal condition, in which surface acrylic polymer coatings are applied along the entire channel section. However, from an economic perspective, a full-section coating is not practical for engineering applications.
Furthermore, a three-dimensional numerical model was established to analyze channel leakage characteristics, as shown in Figure 16. The channel was unfolded along the water flow direction, with a focus on the adjacent sections with and without an impermeable spray coating (i.e., the upstream section without spray coating and the downstream section with spray coating). This scenario is more realistic. To reduce analysis and computational costs, only half of the channel was modeled using the xz plane as the symmetry plane, with the right bank model, where the right slope serves as the water-facing slope. The positive x-axis represents the channel flow direction, with the x = −50 m to 0 m range representing the section without an impermeable coating, and the x = 0 m to 100 m range representing the section with the impermeable coating applied on the lining surface. A drainage body with a thickness of 1.5 m and a width of 2 m was located 1 m below the channel bottom center (green section), and symmetrical modeling was also applied here. The left slope of the model was the back slope, extending leftward and downward (yellow section) to represent the original ground and foundation in accordance with actual topographic elevations. The calculation focuses on the impermeable boundary condition of the channel bed foundation. The permeability coefficient of the impermeable foundation was smaller than that of the channel embankment, simulating the presence of a mudstone barrier at the channel bottom. Additionally, factors such as longitudinal and transverse drainage pipes were included, with the drainage body configured to a smooth boundary condition.
Figure 16.
Three-dimensional numerical model of the channel (x: flow direction; y: cross-channel direction; z: elevation).
Seepage entering the drainage body from the upstream uncoated section (x = −50 to 0 m) raised the seepage pressure within the drainage body. As a result, seepage continued to propagate into the downstream coated section even without direct infiltration from the channel, elevating the phreatic surface within the downstream embankment and producing seepage discharge at low-lying areas near the downstream toe (Figure 17b, red arrow). As shown in Figure 17c, the seepage raised the phreatic surface within the channel embankment, so that leakage bypassed the downstream coated section by traveling along the embankment and emerged at low-lying areas behind it.
Figure 17.
Three-dimensional seepage field of the channel with partial impermeable coating. (a) Three-dimensional view of Darcy’s velocity field (red arrows) and pressure-head contours. The vertical axis is elevation z (m); the bottom horizontal axis is channel distance x (m); the transverse direction is y (m). (b) Cross-sectional (vertical) view of pressure-head contours and Darcy’s velocity vectors (red arrows). (c) Plan view of pressure-head contours.
Based on the above analysis, for channels where a surface spray coating is applied downstream but not upstream, leakage may bypass the downstream impermeable embankment section by traveling along the channel embankment, thereby inducing seepage in low-lying areas behind the impermeable section. Conversely, once bypass seepage occurs upstream, the water head in the downstream channel segment increases. Following a water withdrawal period, if the drainage body cannot rapidly drain accumulated water, a phenomenon of “internal water seeping outward” (reverse seepage) will occur at the junction between coated and uncoated sections. This implies that water pressure acts directly on the interface between the acrylic polymer coating and the lining. If the water level within the channel slope cannot be effectively lowered following water cessation, reverse seepage from the channel slope into the dry channel may occur, introducing uncertainty in the application of this material.
To provide a mechanical basis for segmented coating design, the stress distribution of the channel lining was analyzed using the coupled thermo-hydro-mechanical model for a prototype arc-bottom trapezoidal channel (height 7 m, slope ratio 1:2.5). The results showed that during the water-stoppage and thawing periods, the stress variation across the entire lining was relatively small. However, at the moments of maximum water level and maximum frost heave, the internal lining stress increased significantly, exhibiting an overall pattern of “tension at the lower part and compression at the upper part”: the range from the lower one-third of the lining slab to the channel bottom was in a tensile state, with a maximum tensile stress of approximately 0.3 MPa located at the channel bottom; the upper range was in a compressive state, with a maximum compressive stress of approximately 0.7 MPa located at the channel top. When the settlement difference between the slope top and slope bottom at the moment of maximum water level did not exceed 10 cm, the internal lining stress also exhibited the “tension at the lower part and compression at the upper part” distribution, with the maximum tensile stress not exceeding 0.3 MPa. Based on these stress characteristics, the selection of acrylic polymer coatings should follow the principle of “adopting a high-strength component mass ratio in the lower tensile zone and appropriately reducing the material grade in the upper compressive zone”. The lining stress distribution along the channel length is presented in Figure 18.
Figure 18.
Stress distribution of the channel lining along the length direction.
Based on the numerical and field findings, the following design recommendations are provided for the application of an acrylic polymer coating: (i) Full-section coating is recommended for channels with a high leakage risk, deep excavation, and high internal water pressure, where the economic cost can be justified by the safety benefits. Localized coating is appropriate for channels with moderate leakage and lower internal water pressure, where cost-effectiveness is the primary concern. (ii) The three-dimensional seepage analysis (Figure 17) indicates a significantly higher hydraulic gradient at the junction between coated and uncoated sections, posing a reverse seepage risk. A transition length of at least 50 m (corresponding to the uncoated segment length in the 3D model) is therefore recommended, but this value should be verified and adjusted based on field monitoring and site-specific foundation conditions. (iii) Drainage systems must be integrated with the coating system: longitudinal drainage pipes should be installed at the channel bottom and transverse drainage pipes should be spaced at intervals of 50–100 m, with drainage bodies configured to maintain smooth boundary conditions. The drainage capacity should be designed with adequate redundancy to handle the maximum expected seepage rate, particularly during rapid drawdown periods. (iv) The coating has inherent limitations that should be explicitly acknowledged. The reverse-seepage resistance depends strongly on whether reinforcing fabric is installed. For the coating alone (SS-25 test, no fabric), backwater-side breakthrough occurs at a water head as low as approximately 1 m (0.01 MPa). With the recommended reinforcing fabric and interfacial agent (HP-40 test), this threshold increases to approximately 0.15 MPa (about 15 m water head). Nevertheless, when the backwater pressure exceeds this enhanced threshold, reverse seepage may still occur, particularly at lining joints and in deeply excavated channels. Under such conditions, the coating must be used in conjunction with active drainage measures to prevent internal water pressure buildup.
5.3. Material Property Testing and Economic Analysis
5.3.1. Test Raw Materials
Based on the aforementioned engineering boundary conditions and economic applicability, the two-component acrylic polymer coating selected in this study was composed of an acrylic polymer emulsion (Component A, liquid) and a cement-based mineral powder (Component B, powder). The main crystalline phases of Component B include dolomite (CaMg(CO3)2), calcite (CaCO3), calcium oxide (CaO), dicalcium silicate (Ca2SiO4), and calcium-magnesium-aluminum oxide (Figure 19), which are mixtures of inorganic minerals derived from natural ores or calcination processes. The effects of different A/B mass ratios on the engineering applicability of this acrylic polymer coating were systematically evaluated.
Figure 19.
XRD pattern of Component B (cement-based mineral powder).
5.3.2. Test Methods and Performance Measurements
Tensile performance test: According to GB/T 16777-2008 [60], dumbbell-shaped specimens with a thickness of (2.0 ± 0.4) mm were adopted. After curing under standard conditions for 7 days, aging treatments were performed, including water immersion at (23 ± 2) °C for 7 days, heat treatment at (80 ± 2) °C for 200 h, low-temperature treatment at −45 °C for 200 h, and ultraviolet aging for 1500 h. A CMT4204 electronic universal testing machine was used to measure the tensile strength. For each mass ratio and aging condition, five replicate specimens were prepared and tested, and the results are reported as mean values.
Bond performance test: The conventional water-immersion bond performance was tested using figure-eight mold specimens in accordance with GB/T 16777-2008. For the bond performance test under high water head, concrete cylindrical specimens (300 mm in diameter and 100 mm in height, axially split into two semicylinders) were used to simulate the cast-in-place concrete lining of the channel. The two specimens were joined, and pervious mortar was poured between them to simulate the joint, with a joint width of 15 mm and a coating thickness of 5 mm (including reinforcing fabric), to replicate the lining structure in actual channel engineering. The specimen consisted of, from the surface to the substrate, the impermeable coating, reinforcing fabric, interfacial agent (Component A:water = 1:1), and concrete substrate. An HP-40 automatic pressurized concrete permeameter was used for the test. Each test condition was replicated with five specimens, and the results were averaged.
Permeability performance test: An SS-25 cement-soil permeameter was used to prepare hollow mortar specimens with a bottom diameter of 80 mm and a height of 30 mm. After curing for 72 h, the hollow specimens were filled with pervious concrete (stone:cement:water = 3.5:1:0.4) to simulate the interior of the channel foundation and the lining joints. After curing, a layer of filter paper was attached to the specimen surface, and the impermeable coating was applied according to the experimentally designed mass ratio to simulate two actual channel conditions: external water inward seepage on the water-facing surface and internal water outward seepage on the backwater surface. Stepwise loading was applied with an initial pressure of 0.01 MPa, increasing by 0.01 MPa at each level, with a stabilization time of 10 min per level, and the failure water pressure of the specimens was recorded.
Abrasion resistance test: The test was conducted with reference to the underwater steel ball method in DL/T 5150-2017 [61] (Test Code for Hydraulic Concrete). The coating was applied to the surface of cylindrical concrete substrate specimens (φ300 × 100 mm), with the coating thickness consistent with actual construction. An HKCM abrasion resistance tester was used at a rotational speed of 4000 r/min for a total abrasion test duration of 72 h, and the abrasion resistance strength was calculated.
Given that the channel water-conveyance period runs from April to October each year, the material performance under water-immersion conditions was the primary focus. The radar charts of tensile strength and water-immersion elongation changes in the two-component acrylic polymer materials with different mass ratios after aging by water immersion, low temperature, ultraviolet radiation, and heat treatment are shown in Figure 20.
Figure 20.
Radar chart of strength performance of two-component acrylic polymer materials with different mass ratios.
In the radar charts (Figure 20), each performance indicator increases gradually from the center outward. The 1:1 ratio achieved the highest tensile strength across all aging conditions—approximately 2.0 MPa after water immersion, 1.8 MPa after low-temperature treatment, 1.5 MPa after UV aging, and 1.6 MPa after heat treatment—but its water-immersed elongation was the lowest among the four groups at approximately 300%, exhibiting characteristics of high strength and limited deformation capacity. The 1:0.75 ratio yielded the highest elongation (~500%) and the best toughness, but its tensile strength dropped to 1.0–1.4 MPa across all aging conditions. The 1:0.5 ratio maintained intermediate tensile strength (1.1–1.6 MPa) with moderate elongation (~380%), providing a balanced combination of strength and ductility. Reducing the B content further to 1:0.25 caused overall deterioration: tensile strength fell to 0.9–1.4 MPa and elongation dropped to approximately 200%, indicating that the material loses both strength and deformation capacity when Component B is insufficient.
As shown in Figure 21, the seepage-pressure, bond-strength, and abrasion-resistance results exhibit a clear trade-off among the four A:B mass ratios. On the front-face (water-facing) side without reinforcing fabric (SS-25 test), the 1:0.25 ratio achieved the highest breakthrough pressure of 0.085 MPa, followed by the 1:0.5 ratio (~0.075 MPa), the 1:1 ratio (~0.07 MPa), and the 1:0.75 ratio (~0.06 MPa). On the backwater side without fabric, the ranking reversed: the 1:1 ratio achieved the highest breakthrough pressure of 0.018 MPa, while the 1:0.5 and 1:0.25 ratios dropped to approximately 0.006–0.009 MPa. This imbalance—higher front-face but lower backwater resistance at low B content—arises because excess polymer emulsion forms a more continuous film under unidirectional front-face pressure but lacks sufficient cement hydration products to resist reverse water pressure from the substrate side.
Figure 21.
Radar chart of permeability, bond, and abrasion resistance performance of two-component acrylic polymer materials with different mass ratios.
After incorporating reinforcing fabric and an interfacial agent (HP-40 test), both front- and backwater breakthrough pressures improved substantially. The front-face breakthrough pressure reached approximately 0.43–0.45 MPa across all ratios (0.45 MPa for the 1:0.75 ratio). The backwater-side threshold, however, remained strongly ratio-dependent: the recommended 1:1 ratio achieved the highest value of 0.150 MPa, approximately eight times that of the unreinforced 1:1 specimen (0.018 MPa). The 1:0.25 ratio yielded ~0.10 MPa, while the 1:0.5 and 1:0.75 ratios yielded approximately 0.075 MPa. This confirms that sufficient inorganic powder (Component B) is essential to transfer and distribute backwater tensile stress across the reinforcing fabric.
Bond strength followed a pattern consistent with the mechanical-property results. On a wet substrate, the 1:1 ratio achieved the highest bond strength of 0.542 MPa, decreasing progressively to ~0.40 MPa (1:0.5), ~0.30 MPa (1:0.75), and ~0.20 MPa (1:0.25). On an untreated (dry) substrate, the 1:0.75 ratio ranked highest at 0.600 MPa, while the 1:1 ratio remained above 0.50 MPa. Abrasion resistance was the most sensitive to the A:B ratio: the 1:1 ratio achieved 254 h/(kg·m2), the 1:0.75 ratio halved to 127 h/(kg·m2), and the 1:0.25 ratio deteriorated further.
The above test results indicate that the A:B component ratio has a significant regulatory effect on the mechanical and durability properties of the two-component acrylic polymer coating. Increasing the proportion of Component B can enhance the tensile strength and abrasion resistance under multi-environment conditions but weakens the deformation adaptability of the material. Moderately reducing the proportion of Component B can improve the material toughness, but an excessively low proportion of Component B leads to overall deterioration of environmental durability and mechanical strength. The 1:1 mass ratio emphasizes strength and durability; the 1:0.75 mass ratio is suitable for large-deformation conditions; the 1:0.5 mass ratio achieves a balanced coordination of strength and toughness; and the 1:0.25 mass ratio exhibits poor comprehensive performance and is not suitable for the main impermeable structure under multi-environment coupling conditions.
5.3.3. Economic Analysis of Material Application
This analysis presents a preliminary unit-cost comparison based on material and labor costs only; surface preparation, maintenance, and drainage upgrade costs are not included. The construction procedures of this acrylic polymer coating include: (i) diluting the Component A emulsion with water at a mass ratio of 1:1 and spraying it onto the lining surface as an interfacial agent; (ii) laying a geotextile on the surface as a reinforcing material after the initial setting of the interfacial agent; (iii) mixing Components A and B uniformly at a mass ratio of 1:1 and manually applying the mixture onto the geotextile surface. The total cost for the above procedures mainly includes the material cost of Component A, the material cost of Component B, the geotextile cost, the labor cost, and other costs, among which material and labor costs are the main expenditures. The itemized costs are shown in Table 4.
Table 4.
Itemized costs of the baseline product.
Taking the 1:1 mass ratio as the baseline, the total consumption of Component A per square meter was 2.25 kg (including 0.75 kg of Component A in the interfacial agent), and the consumption of Component B was 1.5 kg. Based on the unit prices in Table 4, the material cost of Component A was 6.34 USD/m2 and that of Component B was 1.69 USD/m2. The comprehensive unit costs after construction for different mass ratios are shown in Table 5.
Table 5.
Economic performance under different mass ratios.
Based on the stress distribution characteristics presented in Figure 18, three material selection schemes were proposed, as summarized in Table 6.
Table 6.
Comparison of material selection schemes.
Although Scheme 3 does not adopt the graded-strength principle, it offers the best cost-performance ratio. The 1:0.5 mass ratio still provides sufficient tensile strength (≥1.0 MPa) for the 0.3 MPa tension zone, with a safety margin exceeding three times.
The three schemes were compared according to their different emphases. Compared with Scheme 1, Scheme 2 could save an investment of 1600 USD per 100 m channel section on both sides, a reduction of 5.2%. Compared with Scheme 1, Scheme 3 could save an investment of 2200 USD per 100 m channel section on both sides, a reduction of 7.1%. If the total length of channel maintenance and reconstruction in spring were 1 km (including both side slopes), Schemes 2 and 3 would save investments of 16,000 USD and 22,000 USD, respectively.
6. Conclusions
This study took the channel renovation project in northern Xinjiang as a case study. A coupled thermo-hydro-mechanical numerical model was developed to simulate the seepage behavior of newly installed seepage-control layers and validated against field monitoring data from three canal sections. The failure mechanisms of these layers under cold-region conditions were investigated, and acrylic polymer-based coatings were evaluated as a surface seepage-control measure. Based on the above analysis, the following conclusions were drawn:
- (1)
- Two-dimensional THM simulations (trends validated by field monitoring, while deformation and safety-factor magnitudes are numerical predictions) show that seepage gradually accumulates beneath the lining during initial operation. After five months of impoundment, the groundwater table rises by approximately 4 m, providing moisture for winter frost heave. The maximum frost-heave displacement reaches 8 cm over the four-month freezing period. Cyclic tensile stress may trigger geomembrane rupture within the 3.5–4.5 m horizontal band from the channel-bottom center when tension exceeds 43 kN/m. In the subsequent operational year, saturated zones develop at rupture locations, and post-shutdown foundation deformation increases to 16 cm, twice the pure frost-heave magnitude. The slope safety factor drops to 1.305, indicating a critically stable condition with a limited anti-sliding margin.
- (2)
- A full-section acrylic polymer coating effectively blocks seepage pathways and keeps the lining-back soil unsaturated; field monitoring records pore water-pressure remaining below approximately 8 kPa after treatment. Freezing-period deformation changes from upward frost heave to thermal contraction, putting the geomembrane under compression. Partial coating brings two major risks at coated-uncoated junctions: embankment-driven bypass seepage and reverse seepage occurring above 0.01 MPa backwater pressure for an unreinforced coating. Reinforcing fabric plus interfacial agent can greatly improve the anti-reverse-seepage capacity. Long-transverse drainage systems are required to dissipate internal pore pressure after channel shutdown.
- (3)
- Laboratory tests reveal that the component A/B mass ratio strongly controls coating performance. The 1:1 ratio achieves optimal tensile strength and abrasion resistance; 1:0.75 yields the highest elongation; 1:0.5 provides balanced strength-ductility. The 1:0.25 ratio shows degraded comprehensive performance and is unsuitable for primary anti-seepage structures. Adding reinforcing fabric and an interfacial agent raises water-facing breakthrough pressure from 0.08 MPa to 0.45 MPa and the backwater threshold from 0.01 MPa to 0.15 MPa. A graded-strength, material-selection scheme can cut project costs by 5.2–7.1% (16,000–22,000 USD per km) without sacrificing safety.
- (4)
- Integrated surface waterproofing and internal longitudinal-transverse drainage are essential to mitigate reverse-seepage-induced instability, following a prevention-oriented principle for cold-region conveyance canals. This 2D plane-strain model neglects longitudinal embankment confinement and adopts a conservative upper-bound geomembrane rupture criterion instead of progressive fatigue damage. Future work should consider 3D modeling, parameter-sensitivity analysis and fatigue-based damage evolution.
Author Contributions
Y.W. (Yingjie Wu): Data curation, Formal analysis, Writing—original draft, Methodology. N.C.: Resources, Investigation, Validation, Writing—review and editing. C.Z.: Supervision, Project administration, Funding acquisition. Y.W. (Yi Wang): Software, Validation, Investigation. Z.G.: Investigation, Validation, Supervision. W.D.: Funding acquisition, Project administration. L.M.: Software, Conceptualization. G.Y.: Conceptualization, Data curation, Visualization, Methodology. Y.W. (Yingjie Wu) and N.C.: contributed equally to this work. All authors have read and agreed to the published version of the manuscript.
Funding
This research is supported by the Open Research Fund of Key Laboratory of Reservoir and Dam Safety Ministry of Water Resources (Grant No. YK324014), Xinjiang Uygur Autonomous Region Natural Science Foundation (Grant No. 2025D01A83), Xinjiang Uygur Autonomous Region Natural Science Foundation (Grant No. 2025D01B111), the Basic Scientific Research Operating Expenses of Autonomous Region Public Welfare Research Institutes (KY2025100) and the Jiangsu Province Natural Science Foundation (Grant No. BK20221193).
Data Availability Statement
Data will be made available on request.
Conflicts of Interest
Authors Wu Dong and Liping Ma were employed by the company Xinjiang Water Development Water Services Group Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
- Lavoie, F.L.; Kobelnik, M.; Valentin, C.A.; do Silva, J.L. Durability of HDPE geomembranes: An overview. Quim. Nova 2020, 43, 656–667. [Google Scholar] [CrossRef] [Scilit]
- Song, L.; Chen, R.K.; Ma, M.Y. Study on the Influence of Hydraulic Factors on the Internal Forces of Rigid Linings in Trapezoidal Channels during Winter Frost Heave. South-to-North Water Divers. Water Sci. Technol. 2018, 16, 158–163. [Google Scholar] [CrossRef]
- Zhang, S.Z.; Bian, H.B.; Dong, X.H. Experimental Study on Shear Strength of Frozen Contact Surface between Subsoil and Channel Concrete Lining. South-to-North Water Divers. Water Sci. Technol. 2017, 15, 164–169. [Google Scholar] [CrossRef]
- Wu, D.; Ma, D.; Wang, C.; Liu, H.; Liu, X. Frost heave deformation and mechanism of canal with high groundwater table in seasonally frozen region. Environ. Earth Sci. 2023, 82, 383. [Google Scholar] [CrossRef] [Scilit]
- Xu, J.; Wang, Q.; Ding, J.; Li, Y.; Wang, S.; Yang, Y. Frost heave of irrigation canals in seasonal frozen regions. Adv. Civ. Eng. 2019, 2367635. [Google Scholar] [CrossRef] [Scilit]
- Cai, Z.Y.; Zhang, C.; Zhu, X. Improvement Capacity and Safety Protection Technology for Long-Distance Water Delivery Projects in Cold Regions. Chin. J. Geotech. Eng. 2022, 44, 1239–1254. [Google Scholar] [CrossRef]
- Cai, Z.Y.; Zhu, X.; Huang, Y.H. Evolution Rules of Fissures in Expansive Soils under Coupled Wetting-Drying and Freeze-Thaw Cycles. Chin. J. Geotech. Eng. 2019, 41, 1381–1389. [Google Scholar] [CrossRef]
- Zhang, C.; Zhu, X.; Huang, Y.H. Directionality of Fissures in Expansive Soils under Coupled Wetting-Drying and Freeze-Thaw Cycles. Chin. J. Geotech. Eng. 2020, 42, 234–238. [Google Scholar] [CrossRef]
- Cai, Z.Y.; Zhu, R.; Huang, Y.H. Effect of Freeze-Thaw Processes on the Degradation Mode of Expansive Soil Channel Slopes. J. Hydraul. Eng. 2020, 51, 915–923. [Google Scholar] [CrossRef]
- Wang, Y.; Liu, J.C.; Liu, Q.H. Shape Optimization of Trapezoidal Channel Structures under Coupled Temperature-Water-Soil Conditions in Cold Regions. J. Tsinghua Univ. (Sci. Technol.) 2019, 59, 645–654. [Google Scholar] [CrossRef]
- Liu, Z.Q.; Zhao, X.; Su, Y.Y. Monitoring and Deformation Modeling of Rebound in Strong Expansive Rock Channel Foundation of the Middle Route of South-to-North Water Diversion Project. South North Water Divers. Water Sci. Technol. 2017, 15, 132–138. [Google Scholar] [CrossRef]
- Cui, H.J.; Xie, Q.Z.; Xiao, J.H. Cause Analysis on the Cracks in Concrete Plate of Channel Lining. Appl. Mech. Mater. 2013, 405–408, 2596–2599. [Google Scholar] [CrossRef] [Scilit]
- Chen, Y.; Huang, Y.H.; Wang, S. Effects of Freeze–Thaw Cycles on Mechanical Properties of Expansive Soils at Different Compaction Degrees. Chin. J. Rock Mech. Eng. 2023, 42, 4299–4309. [Google Scholar] [CrossRef]
- Liu, M.T.; Tian, Z.Z.; Qi, H.Q. Study on Seepage Monitoring Model for High Fill Channels in South-to-North Water Diversion Based on Kalman-BP Fusion. South-to-North Water Divers. Water Sci. Technol. 2018, 16, 179–185. [Google Scholar] [CrossRef]
- Chen, Y.; Huang, Y.H.; Cai, Z.Y. Failure Mechanism and Treatment Measures for Expansive Soil Channels in Cold Regions: A Case Study of the Xinjiang Water Conveyance Channel in China. Cold Reg. Sci. Technol. 2023, 216, 103991. [Google Scholar] [CrossRef] [Scilit]
- He, P.F.; Ma, W.; Mu, Y.H. Experimental Study on Effects of Freeze–Thaw Cycles on Adfreezing Strength at Frozen Soil–Concrete Interface. Chin. J. Geotech. Eng. 2020, 42, 299–307. [Google Scholar] [CrossRef]
- Dai, Z.J.; Guo, J.H.; Luo, H.M. Strength Characteristics and Slope Stability Analysis of Expansive Soil with Filled Fissures. Appl. Sci. 2020, 10, 4616. [Google Scholar] [CrossRef] [Scilit]
- Zhang, J.; Little, N.D.; Hariharan, N. Prediction of Climate-Specific Vertical Movement of Pavements with Expansive Soils Based on Long-Term 2D Numerical Simulation of Rainwater Infiltration. Comput. Geotech. 2019, 115, 103172. [Google Scholar] [CrossRef] [Scilit]
- Mo, T.F.; Lou, Z.K. Numerical Simulation of Frost Heave of Concrete Lining Trapezoidal Channel Under an Open System. Water 2020, 12, 335. [Google Scholar] [CrossRef] [Scilit]
- Khan, S.M.; Hossain, S.; Ahmed, A. Investigation of a Shallow Slope Failure on Expansive Clay in Texas. Eng. Geol. 2017, 219, 118–129. [Google Scholar] [CrossRef] [Scilit]
- Wang, Y.; Wang, Z.Z.; Liu, Q.H. Study on Double Membrane Frost Heave Prevention Layout Based on Elastic Thin Layer Contact Model. Trans. Chin. Soc. Agric. Eng. 2019, 35, 133–141. [Google Scholar] [CrossRef]
- Deng, M.J.; Cai, Z.Y.; Guo, W.L. Analysis of the Role of Vertical Drainage Wells in Stabilizing Expansive Soil Channels in Northern Xinjiang. Chin. J. Geotech. Eng. 2020, 42, 1–6. [Google Scholar] [CrossRef]
- Liu, Y.; Wang, Z.Z.; Wang, Y. Frost Heave Model of Channels Considering the Effects of Moisture Migration and Phase Change on the Temperature Field. Trans. Chin. Soc. Agric. Eng. 2016, 32, 83–88. [Google Scholar] [CrossRef]
- Wang, D.; Fang, P.B.; Han, Y.C. Simulation of Channel Slope Stability of Long-Distance Water Transfer Project. Yellow River 2023, 45, 152–157. [Google Scholar] [CrossRef]
- Zhang, C.; Chen, H.Y.; Wang, Y. Experimental Study on Heat Transfer Characteristics and Thermal Boundary Setting of Centrifugal Model Foundation in Cold Region Engineering. J. Hydraul. Eng. 2023, 54, 729–737. [Google Scholar] [CrossRef]
- GB/T 1040.3-2006; Plastics—Determination of Tensile Properties—Part 3: Test Conditions for Films and Sheets. Standards Press of China: Beijing, China, 2006.
- Rowe, R.K. Long-term performance of contaminant barrier systems. Geotechnique 2005, 55, 631–678. [Google Scholar] [CrossRef] [Scilit]
- Hsuan, Y.G. Data base of field incidents used to establish HDPE geomembrane stress crack resistance specifications. Geotext. Geomembr. 2000, 18, 1–22. [Google Scholar] [CrossRef] [Scilit]
- SL 237-1999; Specification of Soil Test. China Water & Power Press: Beijing, China, 1999.
- Li, X.; Liu, S.; Feng, C. Thermal properties of sedimentary rocks in the Tarim Basin, northwestern China. AAPG Bull. 2019, 103, 1547–1567. [Google Scholar] [CrossRef] [Scilit]
- Belmokhtar, M.; Delage, P.; Ghabezloo, S.; Tang, A.-M.; Menaceur, H.; Conil, N. Poroelasticity of the Callovo-Oxfordian claystone. Rock Mech. Rock Eng. 2017, 50, 871–889. [Google Scholar] [CrossRef] [Scilit]
- Zha, Y.; Yang, J.; Zeng, J. Review of numerical solution of Richardson–Richards equation for variably saturated flow in soils. WIREs Water 2019, 6, e1364. [Google Scholar] [CrossRef] [Scilit]
- GB/T 6672-2001; Plastics Film and Sheeting—Determination of Thickness by Mechanical Scanning. Standards Press of China: Beijing, China, 2001.
- GB/T 1033.1-2008; Plastics—Methods for Determining the Density of Non-Cellular Plastics—Part 1: Immersion Method, Liquid Pyknometer Method and Titration Method. Standards Press of China: Beijing, China, 2008.
- QB/T 1130-1991; Test Method for Right-Angle Tear Properties of Plastics. Standards Press of China: Beijing, China, 1991.
- GB/T 19978-2005; Geotextiles and Geotextile-Related Products—Determination of the Puncture Resistance. Standards Press of China: Beijing, China, 2005.
- GB/T 19979.2-2006; Geosynthetics—Penetration-Resist Property—Part 2: Determination of Penetration Coefficient. Standards Press of China: Beijing, China, 2006.
- Wang, Z.Z.; Sun, T.; Zheng, A.L. Structural Optimization Design of Curved-Bottom Trapezoidal Channels in Cold Regions under Coupled Water-Thermal-Mechanical Effects. J. Cent. South Univ. Technol. 2023, 54, 1916–1929. [Google Scholar] [CrossRef]
- Rowe, R.K.; Sangam, H.P. Durability of HDPE geomembranes. Geotext. Geomembr. 2002, 20, 77–95. [Google Scholar] [CrossRef] [Scilit]
- Ewais, A.; Rowe, R.K. Effect of aging on the stress crack resistance of an HDPE geomembrane. Polym. Degrad. Stab. 2014, 109, 194–208. [Google Scholar] [CrossRef] [Scilit]
- SL 386-2007; Specification for Design of Slope in Water Resources and Hydropower Project. China Water & Power Press: Beijing, China, 2007.
- Teng, R.J.; Gu, X.; Xia, X.Z.; Zhang, Q. Numerical Simulation of Frost Heave Deformation of Concrete-Lined Channel Considering Thermal-Hydro-Mechanical Coupling Effect. Water 2023, 15, 1412. [Google Scholar] [CrossRef] [Scilit]
- Fan, X.J.; Ye, F.; Qin, L.; Yan, Y.P.; Wang, L.R.; Wei, J.F. Frost Heave Characteristics of Lined Channels with Sand-Gravel Replacement in Seasonally Frozen Regions. Sustainability 2025, 17, 9432. [Google Scholar] [CrossRef] [Scilit]
- Fredlund, D.G. Unsaturated Soil Mechanics in Engineering Practice. J. Geotech. Geoenviron. Eng. 2006, 132, 286–321. [Google Scholar] [CrossRef] [Scilit]
- Li, S.Y.; Lai, Y.M.; Zhang, M.Y.; Pei, W.S.; Zhang, C.; Yu, F. Centrifuge and numerical modeling of the frost heave mechanism of a cold-region channel. Acta Geotech. 2019, 14, 1113–1128. [Google Scholar] [CrossRef] [Scilit]
- Griffiths, D.V.; Lane, P.A. Slope stability analysis by finite elements. Geotechnique 1999, 49, 387–403. [Google Scholar] [CrossRef] [Scilit]
- Griffiths, D.V.; Marquez, R.M. Three-dimensional slope stability analysis by elasto-plastic finite elements. Geotechnique 2007, 57, 537–546. [Google Scholar] [CrossRef] [Scilit]
- Han, X.; Wang, X.; Zhu, Y.; Huang, J. A fully coupled three-dimensional numerical model for estimating canal seepage with cracks and holes in canal lining damage. J. Hydrol. 2021, 596, 126094. [Google Scholar] [CrossRef] [Scilit]
- Wang, Z.Z.; Jiang, H.Y.; Wang, Y. Research Progress and Frontiers in Seepage Prevention and Frost Heave Resistance of Water Conveyance Channels in Arid Cold Regions. Trans. Chin. Soc. Agric. Eng. 2020, 36, 120–132. [Google Scholar] [CrossRef]
- Shi, Q.; Luo, W.L. Construction Method of Integrated Equipment for Upgrading Drainage Systems of Water Supply Project Channels in Northern Xinjiang. In Proceedings of the SPIE 12642, Advanced Sensor Systems and Applications; SPIE: Bellingham, WA, USA, 2023; p. 126420U. [Google Scholar] [CrossRef] [Scilit]
- Li, S.Y.; Zhang, M.Y.; Tian, Y.B.; Pei, W.S.; Zhong, H. Experimental and numerical investigations on frost damage mechanism of a channel in cold regions. Cold Reg. Sci. Technol. 2015, 116, 1–11. [Google Scholar] [CrossRef] [Scilit]
- Kim, B.S.; Oh, S.J.; Kim, J.H. Strain concentration ratio analysis of different waterproofing materials during concrete crack movement. Materials 2021, 14, 4495. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ohama, Y. Polymer-based admixtures. Cem. Concr. Compos. 1998, 20, 189–212. [Google Scholar] [CrossRef] [Scilit]
- Zhao, D.M. Application of LEAC acrylic polymer cement in seepage control of water supply channels in northern Xinjiang. Eng. Constr. Des. 2022, 12, 153–155. [Google Scholar] [CrossRef]
- Zhao, D.M. Application and discussion of acrylic cement acrylic polymer coating in leakage repair of main channel in northern Xinjiang. Jiangsu Constr. 2022, 2, 139–141. [Google Scholar] [CrossRef]
- Sakai, E.; Sugita, J. Composite mechanism of polymer modified cement. Cem. Concr. Res. 1995, 25, 127–135. [Google Scholar] [CrossRef] [Scilit]
- Huang, Z.; Xu, J.; Leng, B.; Ren, W.; Chang, S.; Wang, Z.; Xia, W. Study on the effects of powder-liquid ratio and cement ratio on mechanical properties and microscopic characteristics of polymer-cement composite. Adv. Civ. Eng. 2021, 2021, 3283680. [Google Scholar] [CrossRef] [Scilit]
- Mousavifard, S.M.; Unsworth, P.; Johnston, R.; Whittle, A.; Shluger, A. Water exchangeability between pore volumes: A key mechanism governing water diffusion in highly cross-linked polymer coatings. Prog. Org. Coat. 2025, 207, 109405. [Google Scholar] [CrossRef] [Scilit]
- Zhao, Z.G.; Qu, X.L.; Li, J.H. Application of polymer modified cementitious coatings (PCCs) for impermeability enhancement of concrete. Constr. Build. Mater. 2020, 249, 118769. [Google Scholar] [CrossRef] [Scilit]
- GB/T 16777-2008; Test Methods for Building Waterproof Coatings. Standards Press of China: Beijing, China, 2008.
- DL/T 5150-2017; Test Code for Hydraulic Concrete. China Electric Power Press: Beijing, China, 2017.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.




















