Integration of Ground-Penetrating Radar and Synthetic Aperture Focusing Technology for Quantifying Rebar Dimensions

,
and
1
Department of Center for Continuing Education, National Tsing Hua University, Hsinchu 300044, Taiwan
2
Department of Civil Engineering, Chung Hua University, Hsinchu 300110, Taiwan
*
Author to whom correspondence should be addressed.

Abstract

The reinforced concrete structures of many bridges and buildings in Taiwan are over 30 years old. Seismic retrofitting of these structures requires an accurate assessment of reinforcement configuration and corrosion conditions to ensure structural safety and seismic performance. In this study, a 1 GHz ground-penetrating radar (GPR) antenna was used to scan reflected signals from single- and double-row reinforcing bars embedded in concrete. Based on established principles reported in previous studies, detailed analyses were conducted, including the use of the approximate circumference method to estimate reinforcing bar dimensions and the determination of spacing between double-row reinforcing bars (6–8 cm). The synthetic aperture focusing technique was first applied to process the original GPR data matrix. Subsequently, physical parameters related to interface diffraction, such as the perimeter S of the reinforcing bar, were extracted using the dielectric constant of the material interface, the calculated power reflection coefficient, and the First Fresnel Zone. These approaches enabled more accurate estimation of reinforcing bar dimensions (e.g., equivalent to #3 bar size) and improved resolution of spacing between double-row reinforcing bars to 3–6 cm. The results demonstrate that using the synthetic aperture focusing technique to process GPR data enhances the ability to determine reinforcing bar dimensions, interpret bar spacing, and improve imaging resolution, thereby providing a reliable reference for the safety assessment of reinforced concrete structures.

1. Introduction

According to the relevant literature, GPR and SAFT have been widely used in studies on internal material defects, localization, image processing, numerical simulation, and image interpretation. However, relatively few studies have quantitatively analyzed SAFT-processed data, and even fewer have investigated the dimensions of reinforcing steel bars of different grades in concrete. This study examines a three-dimensional synthetic aperture imaging technique for time-domain focusing of pulse-echo radar data. The imaging process, key data-processing issues, and compensation for planar variations in the medium are described. High-resolution volumetric image reconstruction results obtained from concrete test slabs are presented, demonstrating the ability to identify reinforcing steel bars in the images. Finally, the proposed imaging method is briefly compared with diffraction tomography techniques [1]. This study compares the performance of synthetic aperture imaging (SAI) and backpropagation imaging (BPI) algorithms for reconstructing scatterer signatures in time-domain ground-penetrating radar (GPR) data generated by a finite-difference time-domain (FDTD) forward solver. A homogeneous, lossless medium was assumed as the initial condition. The results show that, because the BPI algorithm accounts for wave diffraction, it produces clearer images with fewer artifacts than the SAI algorithm. The advantage of BPI is particularly evident at low frequencies, where the size of the scatterer is comparable to the wavelength of the incident field [2]. Using synthetic aperture radar (SAR) processing in stepped-frequency ground-penetrating radar operating in the 1–2 GHz band, the resolution cell size was approximately 5–15 cm. The results showed that, after SAR processing, small objects could be more easily distinguished from clutter. For example, a non-metallic object with a diameter of 24 cm remained clearly identifiable against clutter even when buried approximately 6 cm deep in dry sand [3]. A novel synthetic aperture radar processing method was proposed for landmine detection on uneven terrain in minefields, enabling clear detection of buried landmines. High-resolution subsurface images were obtained using the proposed synthetic aperture radar processing method, referred to as the ground-adaptive synthetic aperture radar algorithm. A mine-detection robot was developed and used in landmine detection experiments, and the experimental results verified the effectiveness of the system [4]. Moreover, the resolution of GPR is inherently limited by signal attenuation in concrete. The resolution of raw GPR data can be enhanced by applying a synthetic aperture radar (SAR) processing approach. This method produces well-focused GPR profiles with improved lateral resolution for both metallic and non-metallic subsurface features [5]. GPR radargrams of reinforced concrete structures can be processed using a series of digital image processing techniques to evaluate variations in power reflectivity as the antenna moves along the concrete surface. The radii of reinforcing steel bars embedded in the concrete can then be estimated based on the relationship between power reflectivity and the radius of the illuminated area (footprint). Consequently, GPR enables the reliable and accurate estimation of the radii of reinforcing steel bars within concrete structures [6]. Duplex stainless steel, for example, exhibits significant ultrasonic attenuation due to its microstructure. Therefore, the synthetic aperture focusing technique (SAFT) can reduce microstructural noise in the signal, thereby improving defect detectability. To determine the probability of detection (POD) of duplex stainless steel specimens in accordance with the MIL-HDBK-1823 standard [7], conventional methods were used for comparison. The results indicate that applying SAFT to ultrasonic data can significantly enhance defect detectability [8]. Over the past two decades, the focusing of GPR images has remained a challenging issue. Although numerous methods have been proposed, no single migration or focusing technique is universally applicable to all scenarios. Reviews of the principles and algorithmic procedures of the hyperbolic summation method, Kirchhoff migration, back-projection focusing, phase-shift migration, and ω–k migration have been conducted, along with simulation and experimental examples for performance comparison. In addition, several emerging migration approaches have been identified [9]. Studies have shown that SAFT can detect defects at various locations within concrete, including voids around reinforcing bars and elongated linear cracks. Horizontal cracks act as strong scatterers and appear as bright regions in the imaging results, simulating insufficient bonding between concrete and reinforcing steel, which may lead to a loss of structural integrity. However, SAFT is less effective in identifying cracks located very close to the surface. As crack depth increases, multiple reflections of compressional-wave components between the crack and the top surface can contribute to image formation. Therefore, SAFT can serve as an effective diagnostic tool for structural health monitoring [10]. Based on the analytical principles for a single row of reinforcing bars in concrete reported in the literature, further investigations were conducted on the reflected signals and electromagnetic behavior of double-row reinforcing bars. The results indicate that the diffraction characteristic length, denoted as L (i.e., the variation length of power reflectivity), is reduced to half of that observed in the single-row case. Accordingly, for double-row reinforcing bars arranged at the same depth, with identical bar size and a symmetric configuration, a threshold spacing of 14 cm was adopted for evaluation. When the spacing between reinforcing bars is less than 14 cm, the diffraction length at the bar interface is taken as 1/2L; when the spacing exceeds 14 cm, the diffraction length is taken as L. The diffraction length L of the power reflection coefficient at the reinforcing bar interface, together with the First Fresnel Zone, is used to define E, which represents the energy bandwidth of the incident material. Finally, the radius or diameter of the reinforcing bars is inversely estimated using a circular approximation based on these parameters [11]. GPR data were repeatedly collected along multiple lanes, where most of the buried objects were non-metallic. The signal scans acquired by the GPR antenna array were focused by applying multistatic synthetic aperture radar (SAR) imaging techniques, either separately or jointly. An image statistic was proposed based on the ratio of the buried-object energy in the foreground to the soil energy in the background [12]. A ground-penetrating radar (GPR) and synthetic aperture radar (SAR) technique was proposed to account for the effects of refraction at the soil surface and wave propagation in the subsurface. The SAR images of the GPR data were optimized using Fermat’s principle and the Sobel operator to estimate the soil dielectric constant. The effectiveness of the proposed technique was verified through sandbox experiments [13]. A novel method for anti-personnel landmine detection was developed by integrating an unmanned aerial vehicle (UAV) with ground-penetrating synthetic aperture radar (GPSAR). The GPR system consisted of a 1–4 GHz frequency-modulated continuous-wave (FMCW) radar, a radar/lidar altimeter, and a real-time kinematic global navigation satellite system (RTK GNSS). The radar identified suspicious targets for marking, and the Experimental Section presents synthetic aperture radar (SAR) measurement results [14,15]. A fully automated method for the visualization and analysis of GPR data has been proposed. This approach is based on background removal, depth correction, the synthetic aperture focusing technique (SAFT), and interpolation algorithms. First, reinforcing steel bars, as the strongest reflectors of electromagnetic energy, were the most clearly visible features in the images. Second, the reflection amplitudes of steel bars in corrosive environments (i.e., potentially corroded areas) were relatively lower. The method was validated using two concrete bridge decks and two asphalt-overlaid concrete bridge decks, demonstrating its ability to accurately identify corrosion-prone regions. The results were further confirmed by other evaluation methods, including electrical resistivity (ER), half-cell potential (HCP), chloride analysis of core samples, and visual inspection [16]. A SAFT-based algorithm has been proposed for the automated visualization of GPR data in reinforced concrete structures. Four GPR antennas with frequencies of 400 MHz, 900 MHz, 1600 MHz, and 2600 MHz were employed. The quality of the reconstructed images was found to depend on the size and depth of concrete defects and embedded objects, as well as the antenna frequency [17]. The embedded targets in the concrete slabs included reinforcing bars of sizes No. 3 to No. 8 at various depths, as well as artificial voids. By applying the synthetic aperture focusing technique to the GPR data, the results demonstrated that all four antennas were capable of detecting embedded objects within the concrete slabs and improving the quality of both two-dimensional and three-dimensional reconstructed images. Furthermore, higher antenna frequencies yielded better image quality and clarity [18]. This study investigates synthetic aperture radar (SAR) measurements of target scattering beneath a rough air–soil interface. The proposed model assumes: (i) first-order interactions between the target and the air–soil interface, (ii) target scattering below a flat air–soil interface, and (iii) a point-target representation. To test and validate these assumptions, two-dimensional scalar-wave direct scattering problems were simulated, and each data-modeling assumption was examined systematically. The results show that images generated from the modeled data are nearly identical to those produced using measured data simulated from the full direct scattering problem. This demonstrates that the proposed model provides a theoretical framework for subsurface imaging systems [19]. Therefore, the present study integrates GPR detection with the synthetic aperture focusing technique (SAFT) to determine the dimensions of reinforcing steel bars in reinforced concrete structures. First, a GPR system equipped with a 1 GHz antenna was used to acquire signals reflected from single- and double-row reinforcing steel bars embedded in concrete. Second, the ground-penetrating radar matrix data were processed using synthesis and focusing procedures, after which the dimensions of the reinforcing bars were estimated. Third, the diffraction length L of the power reflection coefficient at the steel–concrete interface was extracted from the SAFT-processed data. The energy bandwidth E at the corresponding depth was then calculated, followed by the estimation of the bar circumference S, from which the radius or diameter of the reinforcing bar was determined using the circumference equation. Finally, a quantitative analysis of the reinforcing bar dimensions was conducted. The results demonstrate that integrating GPR detection with SAFT enhances the resolution of GPR profiles for reinforced concrete structures, enabling accurate measurement and clear visualization of reinforcing bar dimensions.

2. Research Methods

2.1. Synthetic Aperture Focusing Technique

This study used the amplitudes and phases of GPR signals reflected from the concrete specimens to reconstruct the specimen images. Both amplitude and phase information were incorporated to improve the signal-to-noise ratio. The focusing position was adjusted to enhance the resolution of the GPR system, and the reconstructed images were used to determine the depths of different points. The cross-section of each tested specimen was divided into several elements at different depths and positions (m, n). The GPR system emitted high-frequency electromagnetic waves toward these elements, which then reflected the waves back to the antenna. Because the wave travel distance differed for each element, the corresponding travel time also varied. The travel time associated with a specific wave path length was calculated using the wave propagation speed in the concrete specimen, as shown in Figure 1.
Figure 1. Wave travel time and propagation distance in GPR.
The value I(m, n) of element (m, n) after superposition averaging is expressed as follows:
I = ( m , n ) = 1 N ∑ i = 1 N T i ( t i ( m , n ) )
where ti represents the time required for a wave to travel from the GPR system to a specific element and back to the GPR system, N represents the total number of data samples, Ti represents the GPR scanning signal, and E(m, n) represents element (m, n). The parameter ti is expressed as follows:
t i ( m , n ) = | S i E ( m , n ) | + | E ( m , n ) R i | V p
where Vp is the wave propagation speed inside the concrete test specimen, Si is the wave source point, and Ri is the point at which the GPR system receives the reflected wave. A SAFT-based program was implemented in a graphical user interface for radar signal processing, as shown in Figure 2.
Figure 2. The ground-penetrating radar data were converted into a data matrix using the SAFT program.
After processing the GPR data with SAFT, the analysis methods and reflection behavior of single steel bars described in reference [6] and double-row steel bars described in reference [11] were applied to the SAFT-processed ground-penetrating radar matrix data.

2.2. Methodology for Hyperbolic Rebar Signatures

In accordance with the approaches used in previous studies on the single rebar dimension analysis method, the power reflectivity in GPR was calculated along the concrete surface. Analysis of the power reflectivity values revealed the reflection paths (B→D) at different positions on the concrete surface, as shown in Figure 3. The variations in power reflectivity were then used to estimate the rebar radius. Figure 3 shows the variation in power reflectivity across different positions on a concrete specimen. The relationship between the rebar circumference (Scor) and the length over which the variation in power reflectivity is examined (L), and the GPR footprint E (i.e., the radius of the First Fresnel Zone) at depth H (i.e., the concrete cover depth) can be expressed as follows:
S c o r = L − E
In the above equation, E is given by E 2 = λ 4 + H ε r + 1 , where λ is the wavelength, εr is the relative permittivity, and H is the depth of the protective row. Therefore, the radius of a rebar (r) can be calculated as follows:
r = S c o r 2 π = L − E 2 π
Figure 3. Variations in power reflectivity (Pr) of a steel rebar in concrete.
In the double-row rebar dimension analysis method, the power reflectivity (Pr) is calculated from the GPR radargrams obtained as the antenna moves along the concrete surface. The signal characteristics of the steel reflector are recorded from the initial reflection to the final reflection. The reflection behavior between double rows of reinforcing bars is symmetrical when the spacing is within 14 cm, with the midpoint between the two bars serving as the boundary (point C in Figure 4). The nominal reflection path corresponds to point B (L/2) in the figure. However, the reflection path from A to S is influenced by the adjacent reinforcing bar, resulting in path deviation. These signal characteristics are used to determine the reflection paths (C–B) at different positions along the horizontal interface; a schematic of the model is shown in Figure 4. Based on variations in power reflectivity, the model enables estimation of the rebar radius.
Figure 4. Effect of power reflectivity (Pr) for buried double rebars in concrete.
The physical model for the radius of double rebars is described in Equation (5). The signals between the two steel bars exhibit superposition characteristics, and cover effects lead to a reduction in the reflection path. In addition, due to variations in the dielectric properties of materials, the reflected electromagnetic energy forms a zone in which the reflection behavior becomes symmetrical, resulting in signal migration; this phenomenon is referred to as multiple reflections. Therefore, the effective power reflection path is reduced to one-half of the original length (L/2), as shown in Figure 4. The corresponding equation is as follows:
r = S c o r 2 π = L 2 ∗ 2 − E 2 π
After SAFT processing, the reflection intensity between the two steel bars in the GPR data matrix becomes more concentrated, clearly highlighting the locations of the steel bars (e.g., point A and point E). The diffraction behavior at the steel bar interface is more pronounced in the upper half of the bars, and the reflected energy at the top forms a symmetrical inverted V-shaped pattern (e.g., point B and point D). A comparison before and after processing shows that the L/2 ratio remains fixed and symmetric. Therefore, the definition of the L/2 measurement position is refined after SAFT processing, as illustrated in Figure 5.
Figure 5. New effect of power reflectivity (Pr) for buried double rebars in concrete.
Figure 3 assumes that the electromagnetic wave diffracts around the steel–bar interface, and the steel bar is approximated as a circle (B–D); the radius is then calculated using the circumference. Figure 4 shows that electromagnetic wave diffraction from the double-row steel bars interacts with each other. Experimental results indicate that, for spacings of up to 14 cm, the trajectory C–B on the inner side of the steel–bar interface is taken as the center. Figure 5 shows that, after SAFT processing, the original electromagnetic wave reflections on both sides of the steel bar disappear, and only the reflection from the top interface of the steel bar is highlighted, as indicated by the inverted V-shaped curves on both sides of point B, as shown in Figure 6.
Figure 6. Evolution of the diffraction behavior of single- and double-row rebars. (a) Diffraction behavior at the reinforcement interface. (b) Diffraction behavior at the interface of double-row rebars. (c) Diffraction behavior at the interface of double-row rebars after SAFT processing.

2.3. Estimation of Rebar Radius by Using the SAFT

After SAFT processing of the GPR data matrix, the L value at the double-row rebar sampling position is corrected using a correction factor R, as shown in Figure 5. Comparison of the reflection behavior before and after SAFT processing revealed that the changes in La and Lb between the two rows of reinforcing bars were synchronous. The reflection path was regular, and the reflected energy was concentrated at the top of the reinforcing bars. Based on the experimental data for the spacing between the two rows of reinforcing bars (3–10 cm), a correction factor R was proposed. In particular, the L/2 position at the top of the rebar is shifted, enabling a more accurate estimation of the rebar radius. Experimental results indicate that the L value before SAFT processing is denoted as La, whereas after SAFT processing it is denoted as Lb. The sampling path for double-row rebar reflection signals after SAFT processing, primarily illustrated in Figure 5, replaces the conventional sampling method shown in Figure 4. The correction coefficient is then determined based on the signals before and after SAFT processing as follows:
R = L b L a
where L a and L b represent the L values obtained before and after SAFT processing, respectively. In this study, R is approximately 0.645. After SAFT processing, the rebar radius is calculated as follows:
r = S c o r 2 π = ( L R ) − E 2 π

3. Experimental

The concrete cover thickness for typical reinforced concrete structures, such as beams, columns, slabs, and walls, is designed to be 2.5–4 cm, and it is generally about 4–6 cm after plastering and ceramic coating. Therefore, this experiment was designed with two configurations: single-row steel bars of different sizes and double-row steel bars of different sizes, as described below:
In this study, a MALA GPR system equipped with a 1 GHz antenna was used to collect data from concrete test specimens. The experimental parameters were a time window of 40 ns and a signal spacing of 0.001 m. The specimens were fabricated in the laboratory and contained steel reinforcing bars with radii of 0.5 cm (Specimen 3), 1.0 cm (Specimen 6), and 1.6 cm (Specimen 10). Figure 7 illustrates the dimensions of the fabricated specimens, all of which have a concrete cover depth of 5.6 cm.
Figure 7. Test configuration for a single row of reinforcing bars, including different combinations of bar sizes.
Tests were conducted on double-row reinforced concrete specimens with steel rebar radii of 0.5, 1.0, and 1.6 cm, a concrete cover depth of 5.6 cm, and rebar spacings ranging from 3 to 10 cm (Figure 8).
Figure 8. Concrete specimens containing double-row steel rebars with spacings of 3–10 cm.

4. Results and Discussion

4.1. SAFT Processing Results for Rebars with Different Radii

First, the GPR matrix data for specimens with different numbers of steel bars were converted into SAFT-matrix data, as shown in Figure 9. The start and end points were extracted from the reflection signal path L of the single-row steel bar, as shown in Figure 4.
Figure 9. Original GPR profiles of different specimens and the corresponding SAFT-processed profiles. (a) The left image shows the GPR profile, and the right image shows the SAFT-processed profile within the red dotted box. The reinforcing bar radius is 1.6 cm. (b) The left image shows the GPR profile, and the right image shows the SAFT-processed profile within the red dotted box. The reinforcing bar radius is 1.0 cm. (c) The left image shows the GPR profile, and the right image shows the SAFT-processed profile within the red dotted box. The reinforcing bar radius is 0.5 cm.
This study calculated the power reflection coefficients of Specimens 10, 6, and 3, with rebar radii of 1.6, 1.0, and 0.5 cm, respectively, before and after SAFT processing. These coefficients were then used to determine the rebar radius of each specimen. After SAFT processing, the V-shaped curve in the GPR profile in Figure 9 disappears, demonstrating the effectiveness of SAFT processing while also highlighting the locations of the reinforcing bars and the concentration of reflected energy. Figure 10 shows the power reflection coefficients calculated for Specimens 3, 6, and 10 before and after SAFT processing.
Figure 10. Power reflection coefficients of different specimens before and after SAFT processing. (a) Rebar No. 10, radius = 1.6 cm. (b) Rebar No. 6, radius = 1.0 cm. (c) Rebar No. 3, radius = 0.5 cm.
The L values obtained from the calculated power reflection coefficients were used to determine the reflection energy coverage range. This calculation was based on the analysis principle for single-row reinforcing steel bars and the first Fresnel zone (E/2). Subsequently, the derived reflection coverage of 8.818 cm was used to determine the dimensions of the reinforcing steel bars, as shown in Table 1.
Table 1. Rebar radius obtained before and after SAFT processing.
The results of the aforementioned analysis are summarized as follows:
  • When the raw GPR profiles were not processed using SAFT, the average errors in the estimated rebar diameters for Specimens 3, 6, and 10 were 106%, 5%, and 6.9%, respectively. This indicates very poor accuracy for the specimen with the smallest rebar radius (0.5 cm).
  • When the raw GPR profiles were processed using SAFT, the average errors in the estimated rebar diameters for Specimens 3, 6, and 10 were 33%, 3%, and 6.3%, respectively. This shows that SAFT substantially improved the accuracy of rebar diameter estimation for Specimen 3 and slightly improved the estimation accuracy for Specimens 6 and 10.

4.2. SAFT Processing Results for Double-Row Rebars with Different Radii

The second set of experiments involved SAFT-processed images of three rebar sizes (#3, #6, and #10) under different rebar spacing conditions ranging from 3 to 10 cm, as shown in Figure 11. When the rebar spacing is excessively small, it is impossible to analyze the double-row rebar images, for example, when the spacing of #6 is 3 cm and the spacing of #3 is 4 cm. This study also calculated the power reflection coefficients of Specimens 10, 6, and 3 for different rebar spacings (3–10 cm) before and after SAFT application. These power reflection coefficients were subsequently employed to determine the rebar radius of the specimens.
Figure 11. SAFT-processed profiles of concrete specimens containing double-row rebars with different spacings. (a) Double-row rebars No. 10 (spacing: 3–10 cm). (b) Double-row rebars No. 6 (spacing: 3–10 cm). (c) Double-row rebars No. 3 (spacing: 3–10 cm).
Figure 11 shows the spacing at which double-row steel bars of different sizes can be resolved or distinguished. Under identical processing conditions, spacings of 3 cm and 10 cm were selected to illustrate the power reflection coefficient distributions of La and Lb, as shown in Figure 12. As illustrated in Figure 12, the original double-row rebars cannot be distinguished when the rebar spacing is 3 cm. However, after SAFT processing, the #10 rebar can be resolved for dimensional analysis, which is the methodology used in this study. Following SAFT processing, rebars of different sizes can be distinguished, and their radii can be accurately analyzed.
Figure 12. Power reflection coefficients of different specimens with a rebar spacing of 3 cm and 10 cm before and after SAFT processing. (a) Rebar No. 10 (left image: spacing of 3 cm; right image: spacing of 10 cm). (b) Rebar No. 6 (left image: spacing of 3 cm; right image: spacing of 10 cm). (c) Rebar No. 3 (left image: spacing of 3 cm; right image: spacing of 10 cm).
Figure 12 illustrates the power reflection coefficients obtained for Specimens 3, 6, and 10 at double-row rebar spacings of 3 cm and 10 cm. The reflection energy coverage range was determined using the estimated La and Lb values to calculate the rebar radii. When the rebar spacing was smaller than these values, the reflection signals from the different rebars could not be distinguished due to mutual interference, preventing accurate rebar radius estimation. Consequently, without SAFT-based processing, the rebar radii for Specimens 10, 6, and 3 could only be calculated when the rebar spacing was greater than or equal to 6 cm, 7 cm, and 8 cm, respectively (Table 2).
Table 2. Radius analysis results for the double-row reinforcement method.
The results of the aforementioned analysis are summarized as follows:
  • When the raw GPR profiles were subjected to SAFT-based processing, the rebar radius for Specimens 10, 6, and 3 could be calculated when the rebar spacing was greater than or equal to 3 cm, 4 cm, and 6 cm, respectively. Consequently, the application of SAFT effectively expanded the rebar spacing range over which the rebar radius could be determined for all specimens, as shown in Table 3.
  • Before SAFT-based processing, the average estimation errors for the rebar diameters of Specimens 10, 6, and 3 were 3.2%, 6%, and 21%, respectively. After applying SAFT, these average errors changed to 3.4%, 4.3%, and 4.6%, respectively. Consequently, SAFT substantially improved the estimation accuracy for Specimen 3, which had the smallest diameter (0.5 cm). Furthermore, SAFT notably improved the accuracy for Specimen 6, although a slight decrease in accuracy was observed for Specimen 10. Overall, applying SAFT to raw GPR profiles significantly enhances the accuracy of rebar radius estimation for reinforced concrete structures with varying rebar spacings and sizes.
Table 3. Radius analysis results after SAFT processing for the double-row reinforcement method.

4.3. Case Analyses

In this study, the SAFT-processed power reflection coefficient diagram, which reflects the diffraction behavior at the rebar interface, was used to analyze rebar dimensions at two structural locations (the bridge bollard and the floor slab) using the circular method, as described below:
First, the SAFT-processed matrix data for the main reinforcement and stirrups within the bridge pier structure are shown in the profile view and the power reflection coefficient diagram in Figure 13.
Figure 13. Reinforcing bar locations and power reflection coefficient distribution in a bridge pier after SAFT processing. (a) SAFT profile of the main reinforcement. (b) Power reflection coefficient distribution of the main reinforcement. (c) SAFT profile of the stirrups. (d) Power reflection coefficient distribution of the stirrups.
Figure 13 shows the dimensions of three main reinforcing bars and five stirrups. The results of the rebar dimension extraction and analysis are presented in Table 4 and Table 5. The verification results after drilling are shown in Figure 14, indicating that the rebar dimensions are consistent and that the image localization is clear.
Table 4. Analysis results of main reinforcing bar dimensions in the bridge footing structure.
Table 5. Analysis results of stirrups reinforcing bar dimensions in the bridge footing structure.
Figure 14. Core-drilling verification of the bridge pier structure. (a) Core-drilling verification of the main reinforcing bars. (b) Core-drilling verification of the stirrups.
Table 5 shows that the error for the first stirrup is excessively high. This is attributed to the insufficient reflected energy of the power reflection coefficient observed in Figure 13d, which leads to incomplete diffraction behavior and prevents an effective evaluation of the stirrup size.
Second, the SAFT-processed matrix data for the reinforcement within the floor slab structure are presented in the profile view and the power reflection coefficient diagram in Figure 15.
Figure 15. Reinforcing bar locations and power reflection coefficient distribution in the floor slab after SAFT processing. (a) SAFT profile of the main reinforcement. (b) Power reflection coefficient distribution of the main reinforcement.
Figure 15 shows the locations of the eight steel bars. Based on the floor slab design specifications, the steel bar diameter ranges from 0.953 cm to 1.27 cm. The average reinforcement size of 1.11 cm is consistent with the SAFT analysis results. As shown in Table 6, the estimation error is within a reasonable range, and the image localization is clear. As shown in Table 6, although the estimated dimensions for the 5th and 6th reinforcing bars are slightly larger, they remain within the design range, indicating that the analysis results are reasonable.
Table 6. Analysis results of reinforcement dimensions for the floor slab structure.

5. Conclusions

The conclusions of this study are outlined as follows:
  • In this study, GPR was combined with SAFT and power reflection coefficient calculations to enhance the accuracy of rebar radius estimation in reinforced concrete structures. This integrated method was applied to estimate the radii of rebars of various sizes in reinforced concrete specimens. High accuracy was achieved for specimens with rebar radii of 0.5 cm, 1.0 cm, and 1.6 cm (Specimens 3, 6, and 10, respectively), with average estimation errors of less than 4.1%. The proposed method also substantially improved the estimation accuracy for specimens with a rebar radius of 0.5 cm (Specimen 3), reducing the average estimation error from 21% (without SAFT) to 4.6%.
  • The proposed method was also used to estimate various rebar sizes and spacings. This approach enabled the accurate estimation of rebar radii for Specimens 10, 6, and 3 at minimum spacings of 3 cm, 4 cm, and 6 cm, respectively; in comparison, the required spacings without SAFT were 6 cm, 7 cm, and 8 cm. Using the proposed method, the estimation errors for the rebar radii of Specimens 10, 6, and 3 were 3.4%, 4.3%, and 4.6%, respectively, yielding an average error of 4.1%.
  • With concrete cover depths of 13–15 cm for bridge pier structures and 6 cm for floor slab structures, accurate rebar size assessments (errors within –1.4% to 3.6%) were achieved using the proposed SAFT processing and power reflection (Pr) diffraction analysis. The results of both laboratory experimental combinations (such as reference with [6,11]) and field structural experiments (bridge piers and floor slabs) demonstrate that the SAFT method proposed in this study effectively refines and enhances rebar image localization for dimensional analysis.

Author Contributions

Conceptualization, C.-H.L.; methodology, C.-H.L.; validation, C.-Y.C. and J.-C.L.; formal analysis, C.-H.L.; investigation, C.-Y.C. and J.-C.L.; resources, C.-H.L.; data curation, C.-Y.C. and J.-C.L.; writing-original draft preparation, C.-Y.C. and J.-C.L.; writing-review and editing, C.-H.L.; visualization, C.-Y.C. and J.-C.L.; supervision, C.-H.L.; project administration, C.-H.L.; funding acquisition, C.-H.L. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The authors have reviewed and edited the output and take full responsibility for the content of this publication. The raw data supporting the conclusions of this article will be made available by the authors on request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
GPRGround-penetrating radar
SAFTSynthetic aperture focusing technique
SARSynthetic aperture radar
SAISynthetic aperture imaging
BPIBackpropagation imaging
FDTDFinite-difference time-domain
PODProbability of detection
UAVUnmanned aerial vehicle
GPSARGround-penetrating synthetic aperture radar
FMCWFrequency-modulated continuous-wave
RTK GNSSReal-time kinematic global navigation satellite system
ERElectrical resistivity
HCPHalf-cell potential

References

  1. Johansson, E.M.; Mast, J.E. Three-dimensional ground-penetrating radar imaging using synthetic aperture time-domain focusing. In Advanced Microwave and Millimeter-Wave Detectors; SPIE: Bellingham, WA, USA, 1994; Volume 2275. [Google Scholar] [CrossRef] [Scilit]
  2. Kagalenko, M.B.; Weedon, W.H. Comparison of backpropagation and synthetic aperture imaging algorithms for processing GPR data. In IEEE Antennas and Propagation Society, AP-S International Symposium (Digest); IEEE: New York, NY, USA, 1996; Volume 3, pp. 2179–2182. [Google Scholar]
  3. Stickley, G.F.; Longstaff, I.D.; Radcliffe, M.J. Synthetic aperture radar for the detection of shallow buried objects. In EUREL International Conference the Detection of Abandoned Land Mines: A Humanitarian Imperative Seeking a Technical Solution; The Institution of Engineering and Technology: Hertfordshire, UK, 1996. [Google Scholar]
  4. Yabushita, H.; Kanehama, M.; Hirata, Y.; Kosuge, K. 3D ground adaptive synthetic aperture radar for landmine detection. In 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS; IEEE: New York, NY, USA, 2005; pp. 2620–2625. [Google Scholar]
  5. Yigit, E.; Demirci, S.; Ozdemir, C.; Kavak, A. A synthetic aperture radar- based focusing algorithm for B-scan ground pene-trating radar imagery. Microw. Opt. Technol. Lett. 2007, 9, 2534–2540. [Google Scholar] [CrossRef] [Scilit]
  6. Chang, C.W.; Lin, C.H.; Lien, H.S. Measurement radius of reinforcing steel bar in concrete using digital image GPR. Constr. Build. Mater. 2009, 23, 1057–1063. [Google Scholar] [CrossRef] [Scilit]
  7. MIL-HDBK-1823; U. S. Department of Defense Handbook—Nondestructive Evaluation (NDE) System Reliability Assessment. U.S. Department of Defense: Arlington County, VA, USA, 1999.
  8. Spies, M.; Rieder, H. Synthetic aperture focusing of ultrasonic inspection data to enhance the probability of detection of defects in strongly attenuating materials. NDT E Int. 2010, 43, 425–431. [Google Scholar] [CrossRef] [Scilit]
  9. Ganguli, A.; Rappaport, C.M.; Abramo, D.; Wadia-Fascetti, S. Synthetic aperture imaging for flaw detection in a concrete medium. NDT E Int. 2012, 45, 79–90. [Google Scholar] [CrossRef] [Scilit]
  10. Özdemir, C.; Sevket, D.; Yiğit, E.; Yilmaz, B. A review on the migration methods in b-scan ground penetrating radar imaging. Math. Probl. Eng. 2014, 280738. [Google Scholar] [CrossRef] [Scilit]
  11. Chang, C.W.; Lin, C.; Lee, S.L.; Chen, P.H.; Jen, C.; Chen, H.L. Non-destructive evaluation of reinforcing rebar radius by digital image GPR technique. Appl. Mechan. Mater. 2014, 501–504, 847–851. [Google Scholar] [CrossRef] [Scilit]
  12. Paglieroni, D.W.; Chambers, D.H.; Mast, J.E.; Bond, S.W.; Beer, N.R. Imaging modes for ground penetrating radar and their relation to detection performance. IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens. 2015, 8, 1132–1144. [Google Scholar] [CrossRef] [Scilit]
  13. Baer, C.; Gutierrez, S.; Jebramcik, J.; Barowski, J.; Vega, F.; Rolfes, I. Ground penetrating synthetic aperture radar imaging providing soil permittivity estimation. In 2017 IEEE MTT-S International Microwave Symposium (IMS); IEEE: New York, NY, USA, 2017; pp. 1367–1370. [Google Scholar]
  14. Schartel, M.; Burr, R.; Mayer, W.; Docci, N.; Waldschmidt, C. UAV-Based Ground Penetrating Synthetic Aperture Radar. In 2018 IEEE MTT-S International Conference on Microwaves for Intelligent Mobility (ICMIM); IEEE: New York, NY, USA, 2018. [Google Scholar]
  15. Fernández, M.G.; López, Y.Á.; Arboleya, A.A.; Valdés, B.G.; Vaqueiro, Y.R.; Andrés, F.L.-H. Synthetic Aperture Radar Imaging System for Landmine Detection Using a Ground Penetrating Radar on Board a Unmanned Aerial Vehicle. IEEE Access 2018, 6, 45100–45112. [Google Scholar] [CrossRef] [Scilit]
  16. Dinh, K.; Gucunski, N.; Zayed, T. Automated visualization of concrete bridge deck condition from GPR data. NDT E Int. 2019, 102, 120–128. [Google Scholar] [CrossRef] [Scilit]
  17. Dinh, K.; Pham, T.T.; Nguyen, T.T.; Vu, H.H. Application of synthetic aperture focusing technique to visualize GPR data from reinforced concrete structures. In IOP Conference Series: Materials Science and Engineering; IOP Publishing: Philadelphia, PA, USA, 2020; Volume 869, p. 052072. [Google Scholar]
  18. Zatar, W.; Nguyen, H.D.; Nghiem, H.M. Influence of frequencies of ground-penetrating radar antennas on detectability of defects and image reconstructability of concrete structures. Forensic Eng. 2022. [Google Scholar] [CrossRef] [Scilit]
  19. Kim, A.; Tsogka, C. Modeling measurements for quantitative imaging subsurface targets. arXiv 2025, arXiv:2501.02696. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.