Abstract
This study evaluated systematic wastewater monitoring for SARS-CoV-2 in Rivera, Uruguay, during 2021 to compare viral loads with reported COVID-19 cases at different population scales and determine community transmission detection thresholds. It also examined post-pandemic viral persistence in Canelones as clinical surveillance declined. Weekly composite influent samples were collected from wastewater treatment plants in Rivera and Canelones during 2021 and 2024–25 respectively. Samples were analyzed via RT-qPCR and matched in Rivera against anonymized, department-level epidemiological data. Three moving windows options were considered for the analysis. A moderate positive correlation between wastewater viral loads and active case rates was statistically significant in Rivera city, and Bisio and Mandubí neighborhoods. Threshold modeling showed 100% wastewater virus detection sensitivity when active prevalence exceeded 17.2 and 15.6 cases per 1000 inhabitants in Rivera and Mandubí respectively for the 21 days window. A positive likelihood ratio indicated that a positive wastewater signal was nearly three times more probable before or during an outbreak. During the post-pandemic period in the initial stage of the study in Canelones, non-detectable or positive but non-quantifiable results predominated, but in October 2024, the viral signal increased in parallel with an increase in clinical cases in the country. Using wastewater surveillance to complement traditional clinical surveillance in Uruguay, particularly at land borders, is both feasible and effective.
1. Introduction
Uruguay is a South American country spanning 176,215 km2, bordering Argentina and Brazil, with a population of approximately 3.5 million inhabitants [1]. Most of the population is urban and resides in small- to medium-sized cities, many of which have established sewerage systems.
The first cases of COVID-19 in Uruguay were identified on 13 March 2020. During the first year of the pandemic, the country implemented intensive clinical surveillance, including diagnostic testing, contact tracing, and quarantine of confirmed cases and contacts. However, widespread community transmission increased markedly during 2021, challenging the capacity of case-based surveillance to fully capture SARS-CoV-2 circulation [2,3].
Wastewater-based epidemiology (WBE) emerged during the COVID-19 pandemic as a complementary approach for monitoring SARS-CoV-2 circulation at the population level. SARS-CoV-2 RNA detection in wastewater has been implemented worldwide, and wastewater viral loads have been associated with trends in reported COVID-19 incidence [4,5]. Because wastewater monitoring captures viral shedding from both symptomatic and asymptomatic individuals independently of healthcare-seeking behavior and access to diagnostic testing, it can provide complementary information to clinical surveillance. In several settings, increases in wastewater viral loads preceded increases in reported cases, providing an early indication of changes in community transmission [5,6,7]. Consequently, wastewater surveillance was incorporated into COVID-19 monitoring frameworks in several countries, including Brazil [8,9,10,11,12,13].
In Uruguay, epidemiological surveillance during the pandemic relied primarily on clinical testing, contact tracing, and mandatory quarantine, while wastewater surveillance was developed by academic research groups as a complementary strategy. The Brazil–Uruguay border represented a particularly relevant setting in which to evaluate this approach. Although international borders were closed to tourists during part of the pandemic, residents of binational twin cities continued to move across the border, where mitigation and surveillance policies were not coordinated. Wastewater surveillance was therefore initiated in November 2020 in Rivera, a Uruguayan city located on the border with Brazil. Initial analysis at the Rivera wastewater treatment plant (WWTP) showed successive changes in SARS-CoV-2 variants that were consistent with clinical sequencing data. Mutations characteristic of the Gamma variant of concern (K417T, E484K, and N501Y) were detected in wastewater as early as December 2020, several weeks before their clinical confirmation [14,15]. These findings supported the potential value of wastewater surveillance for monitoring SARS-CoV-2 circulation in this epidemiologically complex setting.
Based on these initial observations, systematic wastewater monitoring was conducted in Rivera throughout 2021, during a period in which extensive clinical surveillance provided a unique opportunity to compare wastewater SARS-CoV-2 signals with reported COVID-19 cases. Monitoring at both the city WWTP and pumping stations serving individual neighborhoods also allowed the performance of wastewater surveillance to be examined at different population scales. Beyond assessing the association between viral loads and reported cases, these data provided an opportunity to explore the level of community transmission at which SARS-CoV-2 could be consistently detected in wastewater.
The epidemiological context changed substantially after the acute phase of the pandemic. As clinical testing and case reporting decreased, confirmed case counts became progressively less representative of the actual circulation of SARS-CoV-2. Under these conditions, wastewater surveillance may have a different but potentially important role: rather than functioning primarily as a complement to intensive case-based surveillance, it may provide evidence of continued viral circulation when individual testing is limited. To explore this post-pandemic scenario, wastewater surveillance was subsequently implemented in Canelones, a city near Montevideo, the capital city of the country, and maintained during 2024–2025.
Therefore, this study evaluated the usefulness of SARS-CoV-2 wastewater surveillance as a complementary epidemiological tool in Uruguay across pandemic and post-pandemic periods. The first aim of our study was to examine the relationship between wastewater viral loads and reported COVID-19 cases during intensive clinical surveillance in the border city of Rivera, including the capacity of wastewater detection to identify different levels of community transmission. The second aim was to characterize the persistence and temporal variation in SARS-CoV-2 in wastewater during the post-pandemic period in Canelones, when case-based surveillance had substantially decreased.
2. Materials and Methods
2.1. Sample Collection and Pretreatment Methods
Wastewater samples were collected from the Rivera WWTP (the whole city) and two pumping stations in Mandubí and Bisio neighborhoods within the city. Rivera was selected for this study due to its medium population size relative to Uruguay’s scale of 82,602 inhabitants according to the last census (69.295 inhabitants estimated for the study period), a sewerage coverage rate 59.8%, the availability of collaborative plant personnel, and its strategic location on the border with Brazil (Figure 1) [16]. The sampling point was located at the WWTP influent. Four samples were collected hourly between 8:00 and 11:00, once a week, from January to November 2021. Sampling was postponed if rainfall occurred on the collection day or within the preceding 48 h. All samples were refrigerated below 4 °C and transported to the Universidad de la República laboratory in Montevideo, Uruguay, to determine SARS-CoV-2 RNA load via reverse transcription–quantitative polymerase chain reaction (RT-qPCR). During sampling hours, the average flow rate was 340 m3/h, measured at the plant effluent. Flow-proportional composite samples were prepared and analyzed for SARS-CoV-2 RNA. The same protocol was used for sampling the pumping stations for Bisio and Mandubí. No flow was calculated for this sampling, but the number of samples was the same as for the WWTP.
Physicochemical parameters, including Chemical Oxygen Demand (COD), Volatile Suspended Solids (VSS), Total Suspended Solids (TSS), Ammonium Nitrogen (N-NH4+), and pH, were determined from these composite samples following Standard Methods for the Examination of Water and Wastewater [17], in order to determine the general characteristics of wastewater.
After the pandemic, wastewater surveillance continued in the WWTP in Canelones. Canelones was selected due to its proximity to Montevideo, the country’s capital and one of the main urban centers (Figure 1), its population size (24,159 inhabitants), and a sewerage coverage rate of approximately 80.4% [16]. A sampling scheme was established for the period between April 2024 and March 2025, with a weekly frequency during the initial stage and a bi-weekly frequency starting in September 2024. Composite samples were collected to capture the temporal variability associated with the WWTP operation. The sampling point was located at the WWTP influent. Technical staff collected hourly subsamples between 06:00 and 11:00. A flow-weighted composite sample was prepared by combining volumes of each hourly subsample proportional to the corresponding recorded influent flow rate, thereby accounting for variations in wastewater flow during the sampling period.
2.2. COVID-19 Case Database
During the pandemic, the Rivera Departmental Health Division (under the Ministry of Public Health) provided anonymized data on daily confirmed COVID-19 cases. This dataset included whether cases were located in the Bisio or Mandubí neighborhoods or the rest of the city, and was updated, on average, once a month.
Post-pandemic, the low number of symptomatic cases reported in Canelones led to a shift: data from WWTP samples was compared bimonthly against reports from the Ministry of Health’s Division of Health Surveillance [18,19].
2.3. Concentration, Viral Extraction, Detection and Quantification
Viral concentration followed the PEG precipitation procedure previously applied by our group to wastewater from Rivera [14], which is itself a modification of the methods used by Wu et al. [20]. Briefly, 45 mL of each wastewater sample was centrifuged at 4750× g for 30 min. Subsequently, 40 mL of the supernatant was carefully collected without disturbing the pellet and mixed with PEG 8000 (0.1 g/mL) and NaCl (0.0225 g/mL). The mixture was shaken at room temperature for 15 min and then centrifuged at 12,000× g (Sigma 2-16KL, Osterode am Harz, Germany) for 2 h at 4 °C. After centrifugation, the supernatant was discarded, and samples were centrifuged again for 5 min at 12,000× g to remove any residual supernatant. The resulting pellets were resuspended in 140 μL RNase-free Phosphate-Buffered Saline (PBS).
Figure 1.
Regional and national location of sampled cities: Rivera, bordering Brazil, and Canelones in southern Uruguay [21].
Viral RNA was extracted from each concentrate with the QIAamp Viral RNA Mini Kit (Qiagen, Hilden, Germany), according to the manufacturer’s instructions. RNA yield was measured using a NanoDrop™ Lite Spectrophotometer (Thermo Scientific, Waltham, MA, USA).
Quantification of SARS-CoV-2 RNA was performed by one-step RT-qPCR. Samples from Rivera (WWTP and pumping stations) were analyzed with the COVID-19 RT-qPCR Real TM Ambiental (Cy5) kit (ATGen S.R.L., Montevideo, Uruguay), which targets the viral N gene. Amplification was performed in a 20 μL reaction mixture containing 10 μL of extracted RNA from each sample. Every run included the kit’s positive control, and nuclease-free water was used as a non-template control. RT-qPCR cycling conditions were 50 °C for 5 min for reverse transcription and activation at 95 °C for 20 s, followed by 40 cycles of denaturation at 95 °C for 15 s and 60 °C for 30 s. The reactions were run on a Rotor GeneQ (Qiagen, Hilden, Germany). For the Canelones wastewater samples, viral RNA was detected using the GoTaq® Enviro Wastewater SARS-CoV-2 System (AX9330 Promega, Madison, WI, USA), following the manufacturer’s instructions. The assay targeted the SARS-CoV-2 N gene, specifically the N1 region (FAM). Amplification was performed in a 10 µL reaction mixture containing 4 µL of extracted RNA from each sample. A positive control was provided with the kit, and nuclease-free water was used as the non-template control. The RT-qPCR cycling conditions consisted of reverse transcription at 45 °C for 15 min, RT inactivation and GoTaq® activation at 95 °C for 2 min, followed by 40 cycles of denaturation at 95 °C for 15 s and annealing/extension at 62 °C for 60 s. The reactions were performed using a Mic qPCR Cycler (Bio Molecular Systems, Queensland, Australia). Genome copies detected per reaction were scaled according to the concentration and extraction volumes used in the protocol to express SARS-CoV-2 concentrations as genome copies per mL of wastewater.
2.4. Statistical Analysis
The magnitude of the infection in the population was calculated as rates of active cases per 1000 inhabitants. Viral load in wastewater was reported in genomic copies per 100 mL of water sample. The relationship between the two was tested using Spearman correlation and reported as the correlation coefficient and 95% confidence interval in each basin and for each window.
2.4.1. Moving Windows—Active Cases in Pandemic Period
For each sampling event, the number of active cases was calculated as the sum of confirmed cases within three moving window options (21, 14, and 10 days) around the sampling day. For the 21-day window (Window 1), confirmed cases from the 14 days prior to sampling (considered active under the Ministry of Health’s definition) and those confirmed in the 7 days following sampling were included; for the 14-day window (Window 2), confirmed cases from the 7 days prior and 7 days following were included; and for the 10-day window (Window 3), confirmed cases from the 5 days prior and 5 days following were included.
To eliminate the effect of varying population sizes, active cases were expressed per 1000 inhabitants.
2.4.2. Threshold Definition and Optimization
The detection threshold was set as the minimum base-10 logarithm value of genomic copies per 100 mL at which the technique yields positive results. It was set at log10(325).
Since each moving window includes cases confirmed in the days following the sampling date (7 days for Windows 1 and 2; 5 days for Window 3), the resulting threshold reflects the concurrent relationship between wastewater viral load and case counts observed within that window, rather than a threshold validated using only information available at the time of sampling.
The minimum detectable number of active cases per 1000 inhabitants was optimized based on the obtained data; the value selected was the number of active cases within the moving window that maximized the positive likelihood ratio (LR+). This ratio is defined as the quotient of the probability of obtaining a positive result (greater than log10(325)) in PCR quantification when the number of active cases exceeds the threshold, divided by the probability of obtaining a positive result when the number of cases is equal to or less than the threshold.
where u* is the threshold value of the proportion of detectable active cases per 1000 inhabitants to be optimized, ca is the actual proportion of detectable active cases per 1000 inhabitants, log10cg is the base-10 logarithm of genomic copies detected per 100 mL, and log10(325) is the technique’s detection threshold. The optimization was performed within a range of 0 to 50 active cases per thousand inhabitants during the active window, using 100 bootstrapped samples of the observed viral loads.
Once the threshold for detectable cases (u*) was calculated, the sensitivity (s) and false-positive rate (α) values were obtained:
To evaluate differences in behavior between windows, LR+ values (probability of observing a true positive to the probability of a false positive) were compared as a function of u*. These relationships between genomic copies/100 mL and the rate of active cases per 1000 inhabitants by basin and window were tested using a Spearman correlation.
Analysis of the post-pandemic period was done by displaying values of genomic copies detected in wastewater samples over time and comparing them with information on active cases in the city reported by the Ministry of Health during the study period.
2.5. Ethical Considerations
Although this study utilizes data derived from human subjects, all information was analyzed in an aggregated format, making individual identification impossible. No names or personal identifiers were collected or included in the analysis. Furthermore, all data provided by the Ministry of Public Health was fully anonymized prior to access.
3. Results
The results presented correspond to data from the pandemic period with samples obtained from the WWTP in Rivera city (the whole city) and two pumping stations in the neighborhoods of Mandubi and Bisio within the city. In the post-pandemic period, samples were obtained from the WWTP in Canelones City. Figure 1 shows the geographical location of Uruguay and both cities.
3.1. Results of the Analysis of Samples Obtained from the Pandemic Period
During the pandemic, there were 46 days of sampling. Positive COVID-19 cases reported by official data were 3063 for the study period: 250 in Bisio neighborhood, 462 in Mandubí and 2351 in the rest of the city. Populations living in the different areas estimated for the study period were: 3147 in Bisio, 6510 in Mandubí, and 59,638 in the rest of the city [16].
Composite samples from the Bisio and Mandubí sub-basins showed average COD, TSS, and VSS concentrations of 470, 170, and 140 mg/L, respectively, compared to 131, 83, and 65 mg/L at the WWTP inlet. Relative to typical municipal wastewater values, Bisio and Mandubí effluents represent a medium-strength concentration, whereas the WWTP influent is characteristic of weak wastewater [22]. Operating for over 20 years, the WWTP treats sewage from across the city, where the earliest collection networks were built in 1930, and coverage remained below 60% in 2023 [16,23]. High infiltration rates inherent to aging infrastructure likely explain the diluted parameters at the plant entrance.
3.1.1. Rates of Active Cases/1000 Inhabitants per Basin
We calculated rates of active cases for each area using the population obtained from the national census as a denominator [16]. Figure 2 shows active case rates per 1000 inhabitants by date and by basin according to the moving windows already defined.
Figure 2.
Active case rates per 1000 inhabitants by sampling date and basin (Bisio and Mandubi sub-basins and total WWTP) in Rivera, Uruguay. Active cases were calculated as the sum of confirmed cases within a moving window around each sampling date: (a) Window 1, 21 days (14 days before and 7 days after sampling); (b) Window 2, 14 days (7 days before and 7 days after sampling); (c) Window 3, 10 days (5 days before and 5 days after sampling). Each panel corresponds to one basin.
Between January and May 2021, there was indeed a sharp rise in COVID-19 cases in the department of Rivera (and across Uruguay), reaching historic peaks of active infections early in the year and coinciding with the country’s worst phase of the pandemic during April and May.
3.1.2. Relation Between Genomic Copies of SARS-CoV-2 and Active Cases Rates
The relationship between Log-10 of genomic copies/100 mL in wastewater and active case rate per 1000 inhabitants, by basin and window, is presented in Figure 3.
Figure 3.
Log-10 genomic copies/100 mL in wastewater samples by active case rate per 1000 inhabitants and basin (Bisio and Mandubi sub-basins and total WWTP) in Rivera, Uruguay, calculated using moving windows of (a) 21 days (−14/+7 days from sampling), (b) 14 days (±7 days) and (c) 10 days (±5 days).
The correlation coefficient of genomic copies and active cases, CI95% and p value for each basin and window are presented in Table 1.
Table 1.
Correlation between genomic copies/100 mL and the rate of active cases per 1000 inhabitants by basin and window (w).
Statistically significant positive correlations between wastewater viral load and active case rate during the study period were observed in the WWTP in the city of Rivera (Windows 1, 2, and 3), in Bisio (Windows 1, 2, and 3) and in the Mandubí neighborhood (Windows 1 and 2), but not for Window 3. This reflects a moderate positive correlation, where higher active case rates corresponded to elevated genomic copy counts, but the wide confidence intervals indicate uncertainty regarding the exact strength of this relationship.
3.1.3. Estimation of Thresholds of Detection of Active Cases in the Population Using Load of Genomic Copies in Wastewater
The strongest statistically significant correlation between wastewater viral load and active COVID-19 cases was observed in Window 1 in the Rivera city WWTP (rs = 0.419; 95% CI 0.121; 0.655), while Bisio and Mandubí showed weaker correlations. Threshold values were calculated for the three of them and are graphed in Figure 4, Figure 5 and Figure 6. These calculations were performed using the equations described in the Methods Section (Section 2.4).
Figure 4.
Graphic representation of the estimation of the threshold for Rivera city (WWTP) per window. (a) Window 1: 21 days (−14/+7 days from sampling); (b) Window 2: 14 days (±7 days); and (c) Window 3: 10 days (±5 days).
Figure 5.
Graphic representation of the estimation of the threshold for Bisio per window. (a) Window 1: 21 days (−14/+7 days from sampling); (b) Window 2: 14 days (±7 days); and (c) Window 3: 10 days (±5 days).
Figure 6.
Graphic representation of the estimation of the threshold for Mandubí per window. (a) Window 1: 21 days (−14/+7 days from sampling); (b) Window 2: 14 days (±7 days); and (c) Window 3: 10 days (±5 days).
Thresholds were 17.2, 7.0 and 4.4 in Rivera city, 5.8, 5.2 and 3.0 in Bisio and 15.6, 13 and 9.4 in Mandubí in Windows 1, 2 and 3 respectively. Sensitivity, specificity and likelihood positive ratio (LR+), which represents the accuracy of the test, were not the same for each window in all three sample sources (Table 2).
Table 2.
Threshold of detection of SARS-CoV-2 in wastewater from WWTP, sensitivity, 1-specificity, and LR+ in Rivera city, Bisio and Mandubí per 1000 inhabitants.
To characterize the association between viral load and active case prevalence, viral copy limits were analyzed using the mentioned windows, incorporating case data from days before and after sampling.
At an active case prevalence exceeding 17.2 cases per 1000 inhabitants (Window 1), SARS-CoV-2 genomic RNA was detected in 100% of wastewater samples. This demonstrates high sensitivity (a low false-negative rate) for confirming active population-level infections, a feature particularly valuable following periods of undetectable viral loads. The false-positive rate (1-specificity) was below 40%. The positive likelihood ratio (LR+) was 2.64, indicating that a positive wastewater signal was nearly three times more likely to occur immediately prior to or during an outbreak than during non-outbreak periods. Although this confirms a positive association between the viral signal and imminent case surges, the LR+ remains below the benchmark of 10 required for strong rule-in diagnostic confidence. Diagnostic accuracy in Windows 2 and 3 for Rivera city was lower than in Window 1.
Bisio neighborhood showed lower thresholds for detection than Rivera WWTP for all three windows (5.8, 5.2, and 3.0 active cases per 1000 inhabitants for Windows 1, 2, and 3 respectively) but with a lower sensitivity (70% to 78%). These lower threshold values are associated with higher LR+ values, driven mainly by better specificity values (lower false-positive rates) (Table 2).
Regarding the performance of wastewater viral load in Mandubí, the detection thresholds were lower than those calculated for Rivera WWTP Window 1 (15.6, 13.0, and 9.4 cases per 1000 inhabitants for Windows 1, 2, and 3, respectively), but higher than those obtained for Bisio. This indicates that 100% viral detection at the pumping station was achievable at a lower prevalence threshold than in Rivera WWTP. The false-positive rate and the likelihood of signal detection during an outbreak in Mandubí were almost comparable to those observed in Rivera Window 1 (34.8% and LR+ = 2.87, respectively).
3.2. Results of the Analysis of Samples Obtained from the Post-Pandemic Period
A total of 51 wastewater samples were obtained—26 influent samples and 25 effluent samples—distributed between April 2024 and March 2025. During the first sampling stage (April to July 2024), samples were collected on a weekly basis. From September 2024 onwards, the sampling schedule shifted to a frequency of approximately every 15 days. No samples were obtained for August, as sampling could not be performed due to logistical issues associated with the WWTP.
The average physicochemical parameters at the Canelones wastewater treatment plant inlet were COD (Chemical Oxygen Demand) 460 mg/L, TS (Total Solids) 740 mg/L, TSS (Total Suspended Solids) 210 mg/L, VS (Volatile Solids) 320 mg/L and VSS (Volatile Suspended Solids) 150 mg/L. These are typical average values for wastewater treatment plants in Uruguay. The plant was designed to serve 20,000 inhabitants.
During the initial sampling stage, hourly influent flow rates at the WWTP were recorded between 06:00 and 11:00 h to characterize hydraulic variability during the collection window. The cumulative flow rate during this period showed considerable variation between dates, ranging from 303 to 863 m3/h; this variability confirms the appropriateness of preparing the influent samples using a flow-weighted composite method.
Detection and Quantification of SARS-CoV-2
SARS-CoV-2 genomic copies detected in wastewater samples showed a variable signal throughout the monitoring period. Quantifiable concentrations ranged from 9.3 to 84 gc/mL, with the highest values recorded in late November 2024 and early January 2025 (Table 3).
Table 3.
Cycle threshold and genomic copies by wastewater sampling date.
During the initial stage of the study, non-detectable or positive but non-quantifiable results predominated, with only sporadic low-level quantifiable concentrations. From October 2024 onward, the viral signal increased, as reflected by a higher frequency of quantifiable results in wastewater from the city of Canelones entering the WWTP.
4. Discussion
This study primarily aimed to investigate the concordance between SARS-CoV-2 concentrations in wastewater and clinically reported COVID-19 cases under an intensive surveillance framework in the border city of Rivera, Uruguay. A significant positive correlation was observed between wastewater viral loads and reported clinical cases across all three windows of analysis, both in samples of the Rivera WWTP and the Bisio pumping station, and for windows 1 and 2 for Mandubí pumping station. The strongest association was observed in the WWTP samples, using the 21-day moving window encompassing the 14 days preceding and 7 days following wastewater sampling. These findings support the potential of wastewater monitoring as a complementary indicator of SARS-CoV-2 transmission dynamics in the community.
The period from January to May 2021 was characterized by a distinct surge in COVID-19 incidence in Rivera, largely propelled by the introduction and rapid spread of the Gamma variant originating from Brazil [24]. Notably, by February 2021, the Gamma variant represented 80% of sequenced isolates in Rivera, contrasting sharply with its low prevalence in other Uruguayan regions. The parallel increase in viral genomic copy numbers detected at the WWTP (Figure 3) corroborated the rapid epidemiological shift occurring along the border. These wastewater dynamics reflected the transboundary epidemiological behavior typical of this region, where fluid binational interactions and daily cross-border movement between Rivera and Santana do Livramento enabled sustained viral transmission. Consequently, wastewater surveillance proved to be a useful tool for capturing real-time transmission dynamics in a highly connected frontier setting.
The correlation coefficient (rs = 0.419; 95% CI 0.121, 0.655) for Rivera city showed a moderate association between active cases in the population and viral loads in wastewater. Similar results were reported by other authors: Li et al. [25] reviewed 27 studies that correlated viral RNA load in wastewater and with COVID-19 clinically confirmed cases and found that correlation coefficients varied (samples were collected in WWTPs of big and small cities, hospitals, or university dorms). They found 133 correlation coefficient values ranging from −0.38 to 0.99 [25]. The correlation with new cases was stronger than that with active cases and cumulative cases, probably due to shedding dynamics with higher shedding loads from new patients [26,27]. In our study, the time window that best fit the correlation was a 21-day window, with the highest number of potentially infected people who contributed to the viral load of wastewater, regardless of whether they were symptomatic or not, new cases, or cumulative cases. This may partly explain the mild correlation observed.
Variability in SARS-CoV-2 RNA quantification within the same sample associated with the use of different primer and probe sets has been previously reported [28]. However, within the Rivera pandemic-period dataset used for correlation and threshold analyses, a similar RT-qPCR assay (both assays targeted the SARS-CoV-2 N gene), instrument, and analytical procedure were applied throughout the study, thereby minimizing analytical variability within that dataset.
Other explanations for the moderate/mild correlation could include the characteristics of the sewer network and the WWTP in the city of Rivera. It is an old system, in which the first networks are 96 years old, so high infiltration rates can be expected, which dilute the wastewater concentration. The average physicochemical parameters showed highly diluted wastewater at the WWTP influent. Other authors have reported that diluted wastewater may contribute to low detection or non-detection of genomic loads in wastewater samples, and this may have been the case here [29]. The WWTP serves a population of approximately 50,000 inhabitants. Detection rates in wastewater are strongly and positively associated with the population size of wastewater treatment plant catchments (>100,000 people) for the majority of samples [30].
Sampling characteristics in the WWTP are a strong determinant of the probability of detecting SARS-CoV-2 in wastewater. In our study, composite samples were prepared from grab samples collected hourly between 08:00 and 11:00 am. Sampling was done by the same staff member of the WWTP during the whole period, and the composite sample was prepared by a single operator; therefore, very low variability in the process is to be expected. However, the once-weekly sampling frequency may have been insufficient according to Feng et al. [28]. to capture short-term fluctuations. These authors analyzed 12 wastewater treatment plants from August 2020 to January 2021. Analysis of daily sampling demonstrated that a minimum of two samples collected per week were needed to maintain accuracy in trend analysis [28]. According to the Centers for Disease Control and Prevention, the ideal sampling frequency for active surveillance (early indication of infection trends mainly useful during a pandemic) is two or three times weekly. This sampling frequency provides the optimal balance for establishing timely epidemiological trends, detecting early surges, and calculating multi-sample moving averages [31].
Delays between symptom onset, testing, and the reporting of test results have been suggested as possible sources of variability in the correlation between wastewater SARS-CoV-2 concentrations and reported clinical cases due to a lower number of active cases being detected and reported [32]. However, this factor may have had a limited impact in our study, since testing was universally available for the population at that time, and there was a high level of public awareness regarding the clinical manifestations of COVID-19.
Finally, extreme variations in temperature are a factor cited as contributing to the variability of the virus in WWTP samples, because elevated ambient and water temperatures accelerate RNA decay and protein denaturation via increased extracellular enzymatic activity [33]. Although wastewater temperature was not monitored during sampling, Uruguay has a temperate climate, and wastewater flowing through underground sewer networks may be buffered against short-term fluctuations in ambient temperature. This is consistent with wastewater temperature modeling studies that account for the thermal influence of surrounding soil, including estimates for cities at comparable southern latitudes, such as Melbourne, Australia [34].
Regarding the results from the Mandubí pumping station, a significant correlation coefficient was observed between the SARS-CoV-2 genomic load and active cases across analysis windows 1 and 2, accompanied by high sensitivity, though only moderate LR+ for the thresholds calculated. In Bisio, thresholds were lower but with a lower sensitivity compared to Mandubi and the WWTPw1 (sensitivity 100%). Results reported by other authors remain heterogeneous. For instance, Pasha et al. evaluated a neighborhood pumping station servicing approximately 1000 households, a scale similar to Mandubí, where new COVID-19 cases were reported weekly throughout the 35-week sampling period; despite this, SARS-CoV-2 RNA was detected in only 12% of the corresponding wastewater samples [35].
Schmiege et al. applied wastewater epidemiology to small-scale areas, for example neighborhoods, to approach wastewater-based SARS-CoV-2 monitoring. They performed whole-genome sequencing on three wastewater samples from sub-sewer sheds to investigate the potential of small-scale detection of SARS-CoV-2 variants within a German metropolitan wastewater system. In the majority (11/18) of the samples collected during six weeks, they detected Ct values between 27.1 and 37.56, which are very similar to our numbers. In their analysis, they also included the identification of single nucleotide variants, which corresponded well with the variants present at the time of the study in Germany [36]. The authors suggest that the small-scale approach may prove particularly useful for the detection and description of spatially confined emerging or existing virus variants circulating in populations. In our study, we did not identify virus variants, but we did use this kind of approach in a previous publication [14].
The second aim of our study was to assess the persistence and temporal variation in SARS-CoV-2 in wastewater during the post-pandemic period, when case-based surveillance had substantially declined. Wastewater surveillance at the Canelones WWTP could be sustained using the same methodological approach applied during the pandemic period, supporting its operational feasibility as a surveillance strategy when clinical data become limited. However, correlations with clinical cases or epidemiological thresholds could not be established because changes in the surveillance strategy implemented by the Ministry of Health meant that case data were no longer available at the city or departmental level. Nevertheless, the detection of SARS-CoV-2 RNA in wastewater provides evidence of continued viral circulation in the population served by the Canelones WWTP. SARS-CoV-2 levels in wastewater showed an increase in late 2024 and early 2025, coinciding with an increase in clinical cases reported at the national level during epidemiological weeks 1 through 3, followed by a decline reflected in subsequent indeterminate results [37]. Although a direct comparison cannot be established because of the different spatial scales of the wastewater and clinical surveillance data, the temporal agreement between both signals supports the potential value of wastewater monitoring for tracking SARS-CoV-2 circulation when local case-based surveillance is limited. Similar findings have been reported in other post-pandemic settings in Latin America. In San Luis Potosí, Mexico, wastewater surveillance conducted across three WWTPs over a one-year post-pandemic period identified an association between viral load detected in wastewater and severe COVID-19 cases that required hospitalization one week after sampling [38].
Our study has limitations and strengths that should be considered.
Official COVID-19 case counts published by the Uruguayan Ministry of Public Health were based on laboratory-confirmed cases recorded in the national surveillance system (SG-DEVISA). However, the interpretation and comparability of these counts changed over time because case ascertainment depended on the testing strategy in place. During the pandemic period, testing was broadly available and included symptomatic individuals, contacts, and people investigated in the context of outbreaks. Subsequently, testing criteria became progressively more selective, focusing mainly on patients requiring hospitalization and, among individuals with mild respiratory illness, on those at higher risk of complications [39,40]. Therefore, reported cases increasingly represented a selected subset of infections and were likely to underestimate community transmission, particularly mild and asymptomatic infections. In this context, the detection of SARS-CoV-2 RNA in wastewater despite low numbers of reported cases should not necessarily be interpreted as a discrepancy between surveillance systems. Rather, it highlights the value of wastewater surveillance as a complementary indicator of community circulation that is less affected by changes in access to and indications for clinical testing.
Low sampling frequency and the characteristics of the wastewater are also limitations to consider.
Surveillance in the post-pandemic period was compared with general national reports. However, an analysis of severe cases of COVID-19 (data from hospital discharges) could be more appropriate for correlations with viral loads in wastewater during non-pandemic periods [38,41]. In these periods, testing strategies were limited, but severe COVID-19 cases requiring hospitalization were accurately captured in hospital discharge databases. Ulloa-Medina et al. observed that although SARS-CoV-2 detection in wastewater during 2023 and 2024 did not correlate significantly with same-week hospitalizations, an increased viral load in wastewater treatment plants preceded increases in pediatric hospital admissions by 11 weeks. Even though the authors acknowledge that this result might be spurious, driven by shared seasonality and multiple testing, they emphasize that environmental monitoring holds potential as an early warning tool in middle-income countries [38].
Furthermore, variations in wastewater flow, dilution, and matrix characteristics, together with differences in sampling and analytical recovery, may contribute to variability in measured SARS-CoV-2 RNA concentrations between sampling events [28]. Wastewater temperature may also influence viral particle stability and viral RNA persistence. Although samples were maintained below 4 °C following collection and during transportation to the laboratory, wastewater temperature at the sampling point was not systematically recorded, representing an additional limitation of this study.
Different RT-qPCR systems were used for Rivera and Canelones; therefore, absolute viral concentrations between the pandemic and post-pandemic study periods should not be interpreted as directly analytically equivalent. The Canelones data were consequently used primarily to describe temporal patterns of SARS-CoV-2 detection during the post-pandemic period rather than for direct quantitative comparison with Rivera.
The greatest strength of this study is the demonstration of the feasibility of conducting COVID-19 surveillance, both during and after the pandemic, by leveraging the existing infrastructure and personnel of the government agency responsible for water management and treatment plants across most of the country, with the participation of academia. While this required a significant coordination effort, it proved feasible at no additional cost. This is a pragmatic study that allows for replicability, if the specific, previously discussed modifications are taken into account.
Another strength is the use of an interdisciplinary and transdisciplinary approach (academia and the government agency responsible for management of water) to test the use of wastewater-based surveillance as an additional monitoring tool, particularly at the land border, a potential entry point for emerging infectious diseases.
The main challenges for the future are addressing the previously described limitations and integrating the information generated by this surveillance method into the existing national information system in the Department of Health Surveillance in the Ministry of Health, so that both types of data (case-based and wastewater-based) can inform public health decision-making and the system can become established as an early warning mechanism, particularly at the border.
5. Conclusions
Using wastewater surveillance to complement traditional clinical surveillance, particularly at land borders, which often serve as primary points of entry for emerging epidemics, is both feasible and effective. Involving government agencies responsible for water management (operating outside the traditional health authority framework) represents a major operational strength that should be leveraged and sustained in future public health strategies.
Author Contributions
Conceptualization, A.A., M.B., C.R., E.G., J.L. and L.B.; methodology, A.A., J.L., E.G., S.C., M.B., C.R., J.R., B.A. and G.B.N.; validation, S.C. and J.R.; formal analysis, G.B.N., P.A. and V.C.; investigation, A.A., M.B., C.R., E.G., J.L. and L.B.; resources, A.A., J.L. and M.A.; data curation, G.B.N., V.C. and P.A.; writing—original draft preparation, A.A.; writing—review and editing, A.A., M.B., C.R., E.G., J.L., L.B., S.C., M.A. and P.A.; visualization, A.A., M.B., S.C., C.R., E.G., J.L. and L.B.; supervision, M.B., C.R. and E.G.; project administration, J.L.; funding acquisition, J.L., M.B. and C.R. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by Espacio Interdisciplinario de la Universidad de la República del Uruguay: “Núcleo Interdisciplinario NIVEAR”, and Obras Sanitarias del Estado de Uruguay (OSE).
Data Availability Statement
The wastewater samples collected and analyzed from the WWTPs are currently under evaluation for separate publications and cannot be made publicly available. Additionally, aggregated COVID-19 case data for the city of Rivera were provided specifically for this study by the Departmental Health Directorate and remain confidential.
Acknowledgments
We would like to acknowledge the a administrative and technical support provided by the Espacio Interdisciplinario and Foundation Ricaldoni and the authorities of Obras Sanitarias del Estado de Uruguay for allowing permanent staff to participate in sample collection at the Canelones and Rivera wastewater treatment plants. During the preparation of this manuscript, the authors used Google Gemini 3.5. https://gemini.google.com/ for the purposes of editing and grammatical and orthographic correction of the text. The authors have reviewed and edited the output and take full responsibility for the content of this publication.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| WWTP | Wastewater Treatment Plant |
| WBE | Wastewater-Based Epidemiology |
| SARS-CoV-2 | Severe Acute Respiratory Syndrome Coronavirus 2 |
| COD | Chemical Oxygen Demand |
| VSS | Volatile Suspended Solids |
| TSS | Total Suspended Solids |
| N-NH4+ | Ammonium Nitrogen |
| RT-qPCR | Reverse Transcription–Quantitative Polymerase Chain Reaction |
| LR+ | Positive Likelihood Ratio |
References
- Ministerio de Asuntos Exteriores, Unión Europea y Cooperación. Uruguay: Ficha País; Oficina de Información Diplomática: Madrid, Spain, 2026. Available online: https://www.exteriores.gob.es/Documents/FichasPais/URUGUAY_FICHA%20PAIS.pdf (accessed on 31 August 2026).
- Ministerio de Salud Pública. COVID-19 en Uruguay del 13 de Marzo al 13 de Setiembre; Ministerio de Salud Pública: Montevideo, Uruguay, 2020. Available online: https://www.gub.uy/ministerio-salud-publica/comunicacion/noticias/covid-19-uruguay-del-13-marzo-13-setiembre (accessed on 31 August 2026).
- Sistema Nacional de Emergencias. Visualizador de Casos Coronavirus COVID-19 en Uruguay; Presidencia de la República: Montevideo, Uruguay, 2020; Available online: https://www.gub.uy/sistema-nacional-emergencias/pagina-embebida/visualizador-casos-coronavirus-covid-19-uruguay (accessed on 31 August 2026).
- World Health Organization. Status of Environmental Surveillance for SARS-CoV-2 Virus: Scientific Brief, 5 August 2020; WHO: Geneva, Switzerland, 2020; Available online: https://apps.who.int/iris/handle/10665/333670 (accessed on 20 August 2026).
- Medema, G.; Been, F.; Heijnen, L.; Petterson, S. Implementation of environmental surveillance for SARS-CoV-2 virus to support public health decisions: Opportunities and challenges. Curr. Opin. Environ. Sci. Health 2020, 17, 49–71. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kumar, M.; Joshi, M.; Patel, A.K.; Joshi, C.G. Unravelling the early warning capability of wastewater surveillance for COVID-19: A temporal study on SARS-CoV-2 RNA detection and need for the escalation. Environ. Res. 2021, 196, 110946. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shah, S.; Gwee, S.X.W.; Ng, J.Q.X.; Lau, N.; Koh, J.; Pang, J. Wastewater surveillance to infer COVID-19 transmission: A systematic review. Sci. Total Environ. 2022, 804, 150060. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Takeda, T.; Kitajima, M.; Huong, N.T.T.; Setiyawan, A.S.; Setiadi, T.; Hung, D.T.; Haramoto, E. Institutionalising wastewater surveillance systems to minimise the impact of COVID-19: Cases of Indonesia, Japan and Viet Nam. Water Sci. Technol. 2021, 83, 251–256. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- de Freitas Bueno, R.; Claro, I.C.M.; Augusto, M.R.; Duran, A.F.A.; Camillo, L.M.B.; Cabral, A.D.; Sodré, F.F.; Brandão, C.C.S.; Viz-zotto, C.S.; Silveira, R.; et al. Wastewater-based epidemiology: A Brazilian SARS-COV-2 surveillance experience. J. Environ. Chem. Eng. 2022, 10, 108298. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Aguayo-Acosta, A.; Oyervides-Muñoz, M.A.; Rodriguez-Aguillón, K.O.; Ovalle-Carcaño, A.; Romero-Castillo, K.D.; Robles-Zamora, A.; Johnson, M.; Parra-Saldívar, R.; Sosa-Hernández, J.E. Omicron and Delta variant prevalence detection and identification during the fourth COVID-19 wave in Mexico using wastewater-based epidemiology. IJID Reg. 2023, 10, 44–51. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Secretaria Estadual de Saúde do Rio Grande do Sul. Centro Estadual de Vigilância em Saúde. Monitoramento Ambiental de SARS-CoV-2; Boletim de Acompanhamento Nº 2. CEVS: Porto Alegre, RS, Brazil, 2020. Available online: https://cevs.rs.gov.br/upload/arquivos/202009/21115806-boletim-informativo-n-2-final.pdf (accessed on 31 August 2026).
- Secretaria Municipal de Saúde de Niterói. Acompanhamento dos Casos de Coronavírus (COVID-19) Niterói—Painel de Análise Evolução COVID-19; Prefeitura Municipal de Niterói: Niterói, RJ, Brazil, 2020; Available online: https://www.arcgis.com/apps/dashboards/391948b197d94f4191aac9d3e560503a# (accessed on 20 August 2026).
- Prado, A.; Fumian, T.M.; Mannarino, C.F.; Maranhão, A.G.; Siqueira, M.M.; Miagostovich, M.P. Preliminary results of SARS-CoV-2 detection in sewerage system in Niterói municipality, Rio de Janeiro, Brazil. Mem. Inst. Oswaldo Cruz 2020, 115, e200196. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cancela, F.; Ramos, N.; Smyth, D.S.; Etchebehere, C.; Berois, M.; Rodríguez, J.; Rufo, C.; Alemán, A.; Borzacconi, L.; López, J.; et al. Wastewater surveillance of SARS-CoV-2 genomic populations on a country-wide scale through targeted sequencing. PLoS ONE 2023, 18, e0284483. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mir, D.; Rego, N.; Resende, P.; Tort, F.; Fernández-Calero, T.; Noya, V.; Brandes-Lamas, M.; Possi, T.; Arleo-Capovilla, M.; Reyes, N.; et al. Recurrent dissemination of SARS-CoV-2 through the Uruguayan–Brazilian border. Front. Microbiol. 2021, 12, 653986. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Instituto Nacional de Estadística. Microdatos Censo 2023 Ponderados; INE: Montevideo, Uruguay, 2023; Available online: https://www.gub.uy/instituto-nacional-estadistica/politicas-y-gestion/microdatos-censo-2023-ponderados (accessed on 20 August 2026).
- Lipps, W.C.; Baxter, T.E.; Braun-Howland, E.B. (Eds.) Standard Methods for the Examination of Water and Wastewater, 24th ed.; American Public Health Association (APHA), American Water Works Association (AWWA), Water Environment Federation (WEF): Washington, DC, USA, 2023. [Google Scholar]
- Ministerio de Salud Pública. Informe Epidemiológico COVID-19: Serie de Informes Actualizados, 2020–2023; MSP: Montevideo, Uruguay, 2021. Available online: https://www.gub.uy/ministerio-salud-publica/comunicacion/noticias/informe-epidemiologico-covid-19-actualizado-18-enero-2021 (accessed on 20 August 2026).
- Ministerio de Salud Pública. Reporte Quincenal de Casos de COVID-19: Semana Epidemiológica 17 (24/04/22 al 30/04/22); MSP: Montevideo, Uruguay, 2022. Available online: https://www.gub.uy/ministerio-salud-publica/comunicacion/publicaciones/semana-epidemiologica-17-del-240422-300422-casos-covid19-0 (accessed on 20 August 2026).
- Wu, F.; Zhang, J.; Xiao, A.; Gu, X.; Lee, W.L.; Armas, F.; Kauffman, K.; Hanage, W.; Matus, M.; Ghaeli, N.; et al. SARS-CoV-2 Titers in Wastewater Are Higher than Expected from Clinically Confirmed Cases. mSystems 2020, 5, e00614-20. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wikipedia, The Free Encyclopedia. Wikimedia Foundation, 2026. Available online: https://es.wikipedia.org/wiki/Uruguay (accessed on 20 August 2026).
- Tchobanoglous, G.; Burton, F.L.; Stensel, H.D.; Tsuchihashi, R.; Metcalf & Eddy, Inc. Wastewater Engineering: Treatment and Resource Recovery, 5th ed.; McGraw-Hill: New York, NY, USA, 2014. [Google Scholar]
- Alonso, J.; Fierro, E.; Ascúe, J.; Gigena, S. Evaluación del Desempeño de Plantas de Tratamiento Secundario de Aguas Residuales de OSE. In Proceedings of the VI Congreso Nacional de AIDIS, Montevideo, Uruguay, 8–9 May 2008. [Google Scholar]
- Giovanetti, M.; Slavov, S.N.; Fonseca, V.; Wilkinson, E.; Tegally, H.; San, J.E.; Alcantara, L.C.J. Genomic epidemiology of the SARS-CoV-2 epidemic in Brazil. Nat. Microbiol. 2022, 7, 1490–1500. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, X.; Zhang, S.; Sherchan, S.; Orive, G.; Lertxundi, U.; Haramoto, E.; Honda, R.; Kumar, M.; Arora, S.; Kitajima, M.; et al. Correlation between SARS-CoV-2 RNA concentration in wastewater and COVID-19 cases in community: A systematic review and meta-analysis. J. Hazard. Mater. 2023, 441, 129848. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Crank, K.; Chen, W.; Bivins, A.; Lowry, S.; Bibby, K. Contribution of SARS-CoV-2 RNA shedding routes to RNA loads in wastewater. Sci. Total Environ. 2022, 806, 150376. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, X.; Kulandaivelu, J.; Guo, Y.; Zhang, S.; Shi, J.; O’Brien, J.; Arora, S.; Kumar, M.; Sherchan, S.P.; Honda, R.; et al. SARS-CoV-2 shedding sources in wastewater and implications for wastewater-based epidemiology. J. Hazard. Mater. 2022, 432, 128667. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Feng, S.; Roguet, A.; McClary-Gutierrez, J.S.; Newton, R.J.; Kloczko, N.; Meiman, J.G.; McLellan, S.L. Evaluation of Sampling, Analysis, and Normalization Methods for SARS-CoV-2 Concentrations in Wastewater to Assess COVID-19 Burdens in Wisconsin Communities. ACS EST Water 2021, 1, 1955–1965. [Google Scholar] [CrossRef] [Scilit]
- Wu, F.; Xiao, A.; Zhang, J.; Moniz, K.; Endo, N.; Armas, F.; Bushman, M.; Chai, P.R.; Duvallet, C.; Erickson, T.B.; et al. Wastewater surveillance of SARS-CoV-2 across 40 U.S. states. Water Res. 2021, 202, 117400. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wu, F.; Xiao, A.; Zhang, J.; Moniz, K.; Endo, N.; Armas, F.; Bonneau, R.; Brown, M.A.; Bushman, M.; Chai, P.R.; et al. SARS-CoV-2 RNA concentrations in wastewater foreshadow dynamics and clinical presentation of new COVID-19 cases. Sci. Total Environ. 2022, 805, 150121. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Center for Disease Control and Prevention. Developing a Wastewater Surveillance Sampling Strategy. Last Reviewed: June 26, 2024. Available online: https://archive.cdc.gov/www_cdc_gov/nwss/sampling.html#:~:text=No%20interventions%20or%20public%20health%20actions%20should,changing%20scientific%20knowledge%20and%20public%20health%20needs (accessed on 10 October 2026).
- Mackey, K.; Ayers, C.K.; Kondo, K.K.; Saha, S.; Advani, S.M.; Young, S.; Spencer, H.; Rusek, M.; Anderson, J.; Veazie, S.; et al. Racial and Ethnic Disparities in COVID-19-Related Infections, Hospitalizations, and Deaths: A Systematic Review. Ann. Intern. Med. 2021, 174, 362–373. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schussman, M.K.; McLellan, S.L. Effect of Time and Temperature on SARS-CoV-2 in Municipal Wastewater Conveyance Systems. Water 2022, 14, 1373. [Google Scholar] [CrossRef] [Scilit]
- Hart, O.E.; Halden, R.U. Modeling wastewater temperature and attenuation of sewage-borne biomarkers globally. Water Res. 2020, 172, 115473. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pasha, A.B.T.; Kotlarz, N.; Holcomb, D.; Reckling, S.; Kays, J.; Bailey, E.; Guidry, V.; Christensen, A.; Berkowitz, S.; Engel, L.S.; et al. Monitoring SARS-CoV-2 RNA in Wastewater from a Shared Septic System and Sub-sewershed Sites to Expand COVID-19 Disease Surveillance. J. Water Health 2024, 22, 978–992. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schmiege, D.; Kraiselburd, I.; Haselhoff, T.; Thomas, A.; Doerr, A.; Gosch, J.; Schoth, J.; Teichgräber, B.; Moebus, S.; Meyer, F. Analyzing Community Wastewater in Sub-Sewersheds for the Small-Scale Detection of SARS-CoV-2 Variants in a German Metropolitan Area. Sci. Total Environ. 2023, 898, 165458. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ministerio de Salud Pública. Boletín Epidemiológico: Semana Epidemiológica 19 (04/05/2025 al 10/05/2025); Área de Epidemiología, MSP: Montevideo, Uruguay, 2025. Available online: https://www.gub.uy/ministerio-salud-publica/comunicacion/publicaciones/boletin-epidemiologico-2025 (accessed on 20 May 2026).
- Ulloa-Medina, O.U.; Hernández-Sánchez, P.G.; Mata-Moreno, G.; Jaime-Rocha, L.R.; Alatorre-Camacho, S.D.C.; Lara-Hernández, I.; Comas-García, M.; Muñoz-Escalante, J.C.; González-Ortiz, A.M.; Torres-González, P.; et al. Wastewater-Based Surveillance of Respiratory Viruses in the SARS-CoV-2 Post-Pandemic Period in Mexico. Viruses 2026, 18, 254. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ministerio de Salud Pública. Resolución N° 512/022: Actualización de Criterios para el Testeo, Vigilancia y Control de COVID-19; MSP: Montevideo, Uruguay, 2022. Available online: https://www.gub.uy/ministerio-salud-publica/institucional/normativa/resolucion-n-512022-actualizacion-criterios-para-testeo-vigilancia-control (accessed on 31 August 2026).
- Ministerio de Salud Pública. Decreto N° 436/023: Actualización de Recomendaciones de Testeo, Método de Financiamiento y Medidas de Control para COVID-19; MSP: Montevideo, Uruguay, 2023. Available online: https://www.gub.uy/ministerio-salud-publica/institucional/normativa/decreto-436023-actualizacion-recomendaciones-testeo-metodo-financiamiento (accessed on 31 August 2026).
- Mustapha, M.M.; Choi, L.E.; Bergroth, T.; Volkman, H.R.; Devlin, K.; Yang, J.; Yehoshua, A.; Khan, F.L.; McLaughlin, J.M.; Nguyen, J.L. Association between SARS-CoV-2 in wastewater and COVID-19 hospitalizations in three countries, 2022–2024. Front. Public Health 2025, 13, 1679596. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.