Skip to Content
Medical SciencesMedical Sciences
  • Article
  • Open Access

26 November 2026

15 Pages

Longitudinal Refractive and Visual Outcomes from 3 to 12 Months After Bilateral Implantation of Complementary Diffractive Multifocal IOL

,
,
,
,
,
and
1
Cathedral Eye Clinic, Belfast BT1 2LS, Northern Ireland, UK
2
Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, 25123 Brescia, Italy
3
School of Mathematics and Physics, Queen’s University Belfast, Belfast BT7 1NN, Northern Ireland, UK
4
Tianjin Medical University Eye Hospital, Tianjin 300070, China
Med. Sci.2026, 14(8), 820;https://doi.org/10.3390/medsci14080820 
(registering DOI)

Abstract

Purpose: To quantify refractive and distance visual changes between 3 and 12 months after bilateral Artis Symbiose multifocal intraocular lens (IOL) implantation. Methods: This retrospective study included 277 patients (554 eyes) undergoing cataract surgery or refractive lens exchange, selected for complete primary postoperative outcomes; indication-specific counts were unavailable. Postoperative-only mixed-effects models included participant and nested-eye random intercepts. Patient-cluster inference and paired patient-level analyses assessed sensitivity. Exploratory equivalence tests were performed using predefined margins, while changes were quantified separately for each eye. Results: Mean sphere increased by +0.114 D (95% CI +0.084 to +0.143) and spherical equivalent (SEQ) by +0.104 D (95% CI +0.078 to +0.131); both remained significant after Holm adjustment (p < 0.001). Cylinder changed by −0.019 D (95% CI −0.041 to +0.004; adjusted p = 0.190). Changes in uncorrected and corrected distance visual acuity were +0.0083 and +0.0055 logMAR, respectively, and were not significant after adjustment. Exploratory tests supported mean changes within ±0.25 D for SEQ and ±0.05 logMAR for uncorrected distance acuity. Absolute within-eye SEQ changes were ≤0.25, ≤0.50 and ≤1.00 D in 75.6%, 94.6% and 99.5% of eyes, respectively. Analyses restricted to 267 recorded complementary MID/Plus pairs yielded comparable conclusions. Conclusions: Small, statistically detectable hyperopic shifts occurred between the recorded postoperative visits. Mean changes remained within the exploratory equivalence bounds, but this does not establish stability in every eye or comprehensive functional stability of the lens system.

1. Introduction

Cataract surgery and refractive lens exchange increasingly aim to provide predictable refractive outcomes and reduce spectacle dependence. Advances in biometry, intraocular lens (IOL) calculation and presbyopia-correcting optics have improved refractive precision, making the durability of the achieved result an important component of outcome assessment. Longitudinal stability is particularly relevant to diffractive multifocal IOLs, for which residual defocus and astigmatism may compromise uncorrected performance across multiple viewing distances. Manifest refraction and high-contrast acuity nevertheless capture only part of visual performance; optical disturbances and subjective visual quality require separate evaluation.
Following uncomplicated phacoemulsification, postoperative refraction generally stabilises relatively early. Prospective studies have reported limited early changes in refraction, although corneal thickness, keratometry and anterior chamber depth may take longer to stabilise [1,2,3]. A systematic review and meta-analysis found no significant differences in sphere, cylinder or spherical equivalent (SEQ) between measurements at one or two weeks and four weeks after surgery, while identifying greater early cylindrical variability in a minority of eyes [4]. More recent evidence in myopic eyes also supports early refractive stabilisation [5]. These studies principally concern the immediate postoperative period rather than subsequent maintenance of the refractive result.
Longer-term assessment remains relevant because refraction may be influenced by the effective lens position, capsular bag behaviour, corneal characteristics and IOL design. Studies of multifocal IOLs have documented changes in the axial position and refraction during the early postoperative months [6], while comparisons of toric and non-toric lenses have examined refractive trajectories across successive visits [7]. Other multifocal IOL studies have reported favourable refractive and visual outcomes over 6–12 months [8,9,10,11]. Longitudinal change and refractive accuracy at a single endpoint therefore provide complementary information.
Visual acuity represents a related but distinct outcome. Uncorrected distance visual acuity (UDVA) reflects residual refractive error together with the optical performance of the eye, whereas corrected distance visual acuity (CDVA) describes distance acuity after refractive correction. Sustained distance acuity has been reported after multifocal IOL implantation [8,9,10,11], although changes in intermediate acuity, contrast sensitivity or other aspects of visual performance may follow a different course [10]. These distinctions limit the conclusions that can be drawn from distance acuity alone.
The Artis Symbiose system (Cristalens Industrie, Lannion, France) comprises complementary diffractive multifocal MID and Plus IOLs with continuous-phase optical profiles. The MID design preferentially supports intermediate vision and the Plus design near vision, while both provide distance vision. A previous evaluation reported favourable binocular visual performance at 3 and 12 months [12], and other studies have examined defocus characteristics, stereopsis and patient-reported outcomes [13,14]. Detailed characterisation of refractive change, including its distribution across individual eyes and its relationship to lens type, can complement these functional assessments. Some participants are likely to overlap with the earlier cohort [12], although the extent of overlap could not be established.
The present study quantified changes in manifest sphere, cylinder and SEQ, together with UDVA and CDVA, between the recorded 3- and 12-month visits after bilateral Artis Symbiose implantation. Secondary objectives were to characterise individual-eye refractive change, evaluate exploratory mean-equivalence bounds and investigate whether postoperative change differed by the recorded lens type, toricity or baseline demographic and biometric characteristics.

2. Materials and Methods

2.1. Study Design and Data Collection

This retrospective observational study included consecutive patients undergoing bilateral cataract surgery or refractive lens exchange with Artis Symbiose multifocal IOL implantation at a single tertiary ophthalmic centre between April 2021 and December 2025. The clinical protocol specified complementary MID/Plus implantation. Inclusion required complete primary visual and refractive outcomes at the recorded 3- and 12-month postoperative visits.
Exclusion criteria comprised coexisting ocular pathology, previous corneal surgery including corneal refractive surgery, corneal disease, amblyopia, ocular inflammation, a history of glaucoma or retinal detachment, neuro-ophthalmic disease, macular disease and postoperative complications. The cohort included both cataract surgery and refractive lens exchange patients; indication-specific counts and cataract severity grades were unavailable.
Demographic characteristics, ocular biometry, implanted IOL power, manifest sphere and cylinder, SEQ, UDVA and CDVA were extracted from clinical records. Distance visual acuity was measured using logarithmic acuity charts (Thomson Test Chart) at 6 m under standard test room lighting; illuminance was not measured in lux. Acuity was recorded directly in logMAR, without conversion from Snellen or decimal notation. The same acuity testing protocol was used at the 3- and 12-month postoperative visits. Manifest sphere and cylinder were extracted from clinical refraction records, and achieved SEQ was calculated as sphere plus half the cylinder. Detailed refraction endpoint criteria and repeatability measurements were unavailable. Baseline measurements were summarised descriptively, and the primary longitudinal comparison used the visits labelled 3 and 12 months.
The study was conducted in accordance with the Declaration of Helsinki and received ethical approval under reference CECREC26-11 from the Cathedral Eye Clinic Research and Ethic Committee (1 April 2021). Written informed consent was obtained. Study data were pseudonymised for analysis and securely stored.

2.2. Intraocular Lenses

The Artis Symbiose MID and Plus IOLs are complementary diffractive multifocal lenses with continuous-phase optical profiles designed for bilateral use. The MID IOL preferentially supports intermediate vision and the Plus IOL near vision, while both provide distance vision. The lenses incorporate anterior modulated diffractive profiles, an aspheric design with −0.23 μm spherical aberration, a 6.0 mm optic and four closed-loop haptics. Spherical powers range from +10.0 to +35.0 D in 0.50 D increments, with toric models available for correction of corneal astigmatism.

2.3. Surgical Technique

Surgery was performed by three experienced surgeons using clear-corneal phacoemulsification under sub-Tenon anaesthesia. A 5.5 mm capsulorhexis was created, and the foldable Artis Symbiose IOL was implanted in the capsular bag through a 2.4 mm clear-corneal incision, followed by insertion of a capsular tension ring. Routine ring implantation was intended to support capsular bag contour and IOL centration. As all eyes received a ring, its contribution to postoperative stability could not be evaluated separately. Biometry was performed using the IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany). IOL power was calculated using the Barrett Universal II, EVO 2.0 or Haigis formula, with the same formula used for both eyes of each patient. Manufacturer-recommended IOL constants were used; surgeon- or centre-specific optimisation was not performed. Emmetropia was the intended refractive target in both eyes. Toric alignment was guided using the ZEISS CALLISTO eye system (Carl Zeiss Meditec AG, Jena, Germany). Surgeon effects were not assessed in this study.
The routine allocation strategy assigned the MID IOL to the dominant eye and the Plus IOL to the nondominant eye. Ocular dominance was assessed using a pointing test, corroborated by the patient’s reported sighting preference when using a camera and/or rifle. The routine sequence was dominant-eye surgery first, followed by fellow-eye surgery one week later.
One patient underwent bilateral Nd:YAG posterior capsulotomy 7 months postoperatively, between the 3- and 12-month assessments. The reported analyses comprise 277 patients (554 eyes); exclusion of this patient has not been implemented in these analyses.

2.4. Data Preprocessing

The baseline and two postoperative datasets were reshaped into an eye-level longitudinal structure retaining participant and eye identifiers. Outcome values were reconciled against the source data. The recorded lens type and toric status were retained without recoding discrepant bilateral configurations. Primary analyses included the complete supplied cohort; a sensitivity analysis was restricted to patients with one recorded MID and one recorded Plus lens.
Baseline covariates comprised age at the recorded eye-specific procedure date, sex, axial length, keratometry, anterior chamber depth and implanted IOL power. The mean keratometry was calculated as (K1 + K2) / 2 and the corneal astigmatism magnitude as |K2 − K1|. Continuous covariates were centred and scaled using their baseline eye-level mean and standard deviation (SD). Alternative covariate specifications used either axial length or IOL power to limit collinearity. Missing adjustment variables were handled by complete-case analysis with explicit denominators.

2.5. Statistical Analysis

Continuous variables are reported as mean ± SD, median, first and third quartiles (Q1–Q3), and range. Refractive outcomes are expressed in dioptres (D) and distance acuity in logMAR. Postoperative changes are reported in their original units.
Each primary outcome was analysed using a postoperative-only linear mixed-effects model fitted by restricted maximum likelihood, with visit and eye laterality as fixed effects and random intercepts for participant and eye nested within participant [15,16]. The 3-month visit was the reference, and the principal contrast was 12 months minus 3 months. Excluding baseline outcomes from these models prevented the substantially greater preoperative refractive variability from determining the residual variance of the postoperative comparison.
Model-based Wald inference was supplemented by a patient-cluster generalised least-squares sandwich covariance estimator with CR1 (Cluster-robust 1) finite-sample correction and a t-reference distribution with G − 1 degrees of freedom, where G is the number of contributing patients. The principal numerical interpretation uses these cluster-based intervals and p-values; model-based results are also reported. An independent paired analysis averaged fellow-eye changes within each patient. This retained the patient as the independent sampling unit and provided a separate check on the estimated mean change.
Exploratory two one-sided tests (TOST) assessed mean change against margins of ±0.25 and ±0.50 D for SEQ and ±0.05 logMAR for UDVA, using patient-averaged paired changes and 90% confidence intervals [17]. The ±0.25 D SEQ margin reflects the conventional quarter-dioptre refraction step, providing a stringent threshold for mean refractive change, while ±0.50 D offers a broader sensitivity bound. The ±0.05 logMAR UDVA margin corresponds to half a standard logMAR chart line, allowing assessment against a small mean visual change. These clinically interpretable margins were not defined prospectively; the analyses therefore remain exploratory and assess bounded mean change without establishing the confirmatory equivalence or stability of individual eyes.
Individual-eye refractive change was characterised by its distribution and the proportions with |ΔSEQ| ≤0.25, ≤0.50 and ≤1.00 D. Residual SEQ within ±0.50 and ±1.00 D of emmetropia was reported separately at each postoperative visit. These accuracy measures were not treated as formula prediction errors. Percentile 95% confidence intervals for proportions and paired proportion differences were obtained from 5000 bootstrap samples of whole patients, preserving fellow-eye observations. A fixed random seed was used to ensure reproducibility.
Refractive prediction error was calculated separately for each eye and visit as achieved SEQ minus the preoperative formula-predicted refraction. Positive errors denote a more hyperopic outcome than predicted. Prediction errors were summarised as mean ± SD, median absolute error and proportions with absolute error ≤0.25, ≤0.50 and ≤1.00 D. One eye lacked a predicted refraction and was omitted only from these summaries, leaving 553 eyes from 277 patients at each visit. These pooled estimates describe the recorded clinical calculation strategy rather than a comparison of individual formulae.
Secondary nested models included recorded lens type, toricity and their interactions with visit, together with laterality. Estimated group means were standardised to the cohort distribution of the other model factors. A within-patient MID-versus-Plus comparison was also performed in the recorded complementary-pair subgroup. Exploratory covariate models included visit interactions with age, sex, mean keratometry, corneal astigmatism, anterior chamber depth and either axial length or IOL power, with additional adjustment for lens type, toricity and laterality. Correlations and variance inflation factors assessed collinearity.
Patients with and without baseline UDVA were compared using descriptive statistics and standardised differences. Additional models assessed postoperative outcome levels and change according to baseline-UDVA missingness, and analyses restricted to patients with observed baseline UDVA were compared with the full cohort. These analyses describe observed differences and do not establish a missing-at-random mechanism.
Holm adjustment [18] was applied across the five principal postoperative contrasts separately for cluster-based and model-based inference; lens type and toricity interactions each formed a separate five-outcome family. The three TOST comparisons formed one Holm family. Missingness analyses used separate families of ten postoperative-level contrasts and five change interactions. The 60 demographic/biometric visit-interaction tests across both covariate specifications were controlled using the Benjamini–Hochberg false discovery rate procedure [19]. Other subgroup contrasts are explicitly labelled exploratory. Reported 95% intervals are pointwise, not simultaneous; adjusted p < 0.05 defined statistical significance.
Analyses used Python 3.12.14, NumPy 2.3.5, pandas 2.2.3, SciPy 1.17.0, statsmodels 0.14.6, Patsy 1.0.2, Matplotlib 3.10.8 and openpyxl 3.1.5. Convergence, likelihood finiteness, fixed-effect covariance estimates and residual plots were examined. Numerical results were checked against independent paired calculations and repeated analysis runs.

3. Results

3.1. Study Population and Baseline Characteristics

The analysis included 277 participants (554 eyes), of whom 162 (58.5%) were female. Mean age at the recorded procedure date was 58.33 ± 7.05 years. Mean axial length, anterior chamber depth and implanted IOL power were 23.30 ± 1.21 mm, 3.16 ± 0.37 mm and 23.53 ± 3.92 D, respectively. Preoperative mean sphere, cylinder and SEQ were +1.61 ± 2.41 D, −0.60 ± 0.55 D and +1.31 ± 2.42 D; mean UDVA and CDVA were 0.42 ± 0.28 and −0.06 ± 0.09 logMAR (Table 1).
Table 1. Demographic characteristics, biometric parameters, and refractive and distance visual outcomes, including refractive prediction error.
Recorded configurations comprised 267 MID/Plus pairs, six MID/MID pairs and four Plus/Plus pairs, corresponding to 279 MID and 275 Plus eyes. Toric models were recorded in 109 eyes (19.7%); 445 eyes (80.3%) received non-toric models. The primary analysis included the 10 patients with the same IOL design in both eyes; sensitivity analyses were restricted to the 267 patients with complementary IOL pairs.
All five primary outcomes were available for all 554 eyes at both postoperative visits. Baseline UDVA was missing in both eyes of 38 patients, leaving 478 eyes from 239 patients with observed baseline measurements. The clinical reasons for missing baseline UDVA were not recorded. Eight eyes had missing adjustment variables, leaving 546 eyes from 276 patients and 1092 postoperative observations in each covariate model. These denominators describe the selected analytic cohort and cannot be interpreted as a 100% follow-up rate among all operated patients.
Patients without baseline UDVA differed from those with observed measurements: the patient-averaged baseline SEQ was −0.602 versus +1.615 D, mean keratometry 43.932 versus 43.161 D, and proportion male 23.7% versus 44.4%. Corresponding standardised differences were −0.624, +0.525 and −0.444. At 12 months, the group without baseline UDVA had a lower mean SEQ by 0.147 D (95% CI −0.247 to −0.048; Holm-adjusted p = 0.040). No missingness-by-visit interaction remained significant after adjustment. The primary postoperative analysis retained all 277 patients (Table S4).

3.2. Longitudinal Refractive Outcomes

The cylinder change was −0.019 D (95% CI −0.041 to +0.004; adjusted p = 0.190; Table 2). Postoperative-only estimated means for sphere were +0.261 D at 3 months and +0.375 D at 12 months; corresponding means were −0.366 and −0.385 D for cylinder and +0.078 and +0.182 D for SEQ (Figure 1; Table 3). Sphere increased by +0.114 D (95% CI +0.084 to +0.143) and SEQ by +0.104 D (95% CI +0.078 to +0.131); both changes remained significant after Holm adjustment (p < 0.001).
Table 2. Postoperative changes from 3 to 12 months with patient-cluster inference.
Figure 1. Refractive outcomes after bilateral Artis Symbiose implantation. Panels (A–C) show the observed distributions of sphere, cylinder and SEQ at baseline and the two postoperative visits. Violin widths depict density; boxes span Q1–Q3, central lines are medians, and whiskers extend to observations within 1.5 interquartile ranges. Panels (D–F) show postoperative-only estimated means, with error bars and shaded bands denoting pointwise patient-cluster 95% confidence intervals. The connecting lines illustrate the two recorded visits and do not estimate intervening measurements.
Table 3. Estimated postoperative marginal means with patient-cluster 95% confidence intervals.
Exploratory TOST analyses supported a mean SEQ change within both ±0.25 and ±0.50 D (90% CI +0.082 to +0.127 D; both adjusted p < 0.001; Table 4). The distribution of individual-eye changes was broader: 419/554 eyes (75.6%) had |ΔSEQ| ≤0.25 D, 524/554 (94.6%) had |ΔSEQ| ≤0.50 D, and 551/554 (99.5%) had |ΔSEQ| ≤1.00 D (Figure 2; Table 5). The median change was +0.125 D (Q1–Q3, 0.000 to +0.250 D). Thirty eyes (5.4%) changed by more than 0.50 D and three (0.5%) by more than 1.00 D.
Table 4. Exploratory equivalence tests of mean postoperative change.
Figure 2. Within-eye spherical-equivalent change from 3 to 12 months after bilateral Artis Symbiose implantation. Panel (A) shows the distribution of ΔSEQ in 554 eyes from 277 patients; the dashed line marks the mean change of +0.104 D and the solid grey line zero change. Panel (B) shows the cumulative proportions with |ΔSEQ| ≤0.25, ≤0.50 and ≤1.00 D. Counts and percentages are displayed above the bars; error bars are percentile 95% confidence intervals from 5000 patient-level bootstrap samples preserving fellow-eye observations.
Table 5. Individual-eye refractive change and residual refraction relative to emmetropia.
The proportion with residual SEQ within ±0.50 D of emmetropia decreased from 453/554 (81.8%) at 3 months to 428/554 (77.3%) at 12 months, a paired difference of −4.51 percentage points (bootstrap 95% CI −8.12 to −0.90). Corresponding proportions within ±1.00 D were 550/554 (99.3%) and 539/554 (97.3%), a difference of −1.99 percentage points (95% CI −3.61 to −0.54). These measures describe residual refraction relative to emmetropia (Table 5).
The mean refractive prediction error was +0.098 ± 0.423 D at 3 months and +0.202 ± 0.433 D at 12 months; median absolute errors were 0.290 and 0.315 D, respectively. At 3 months, the absolute prediction error was ≤0.25, ≤0.50 and ≤1.00 D in 240/553 (43.4%), 419/553 (75.8%) and 543/553 (98.2%) eyes, respectively. Corresponding values at 12 months were 227/553 (41.0%), 398/553 (72.0%) and 532/553 (96.2%). These estimates use each eye’s recorded predicted refraction, rather than emmetropia, as the reference (Table 1).
No visit-by-lens-type interaction remained significant after Holm adjustment (Table 6a). The estimated Plus-minus-MID difference in SEQ change was +0.003 D (95% CI −0.040 to +0.047; adjusted p = 1.000). Toric eyes showed a greater SEQ shift than non-toric eyes, with an adjusted difference in change of +0.116 D (95% CI +0.043 to +0.188; adjusted p = 0.010; Table 6b). The corresponding sphere interaction was +0.098 D but did not remain significant after adjustment (p = 0.076). These observational contrasts do not establish causal effects of lens design or toricity. No toric IOL required postoperative realignment during follow-up. Quantitative postoperative rotation measurements were unavailable.
Table 6. Postoperative outcomes and differences in change by recorded IOL design.

3.3. Longitudinal Visual Acuity Outcomes

The estimated mean UDVA was 0.0266 logMAR at 3 months and 0.0349 logMAR at 12 months (Figure 3; Table 3). The change was +0.0083 logMAR (95% CI −0.0003 to +0.0168; Holm-adjusted p = 0.173). Exploratory TOST supported a mean change within ±0.05 logMAR (90% CI +0.0011 to +0.0154; adjusted p < 0.001; Table 4).
Figure 3. Distance visual acuity after bilateral Artis Symbiose implantation. Panels (A,B) show observed UDVA and CDVA distributions. Violin widths depict density; boxes span Q1–Q3, central lines are medians, and whiskers extend to observations within 1.5 interquartile ranges. Baseline UDVA includes 478 eyes; other plotted primary measurements include 554 eyes. Panels (C,D) show postoperative-only estimated means with pointwise patient-cluster 95% confidence intervals, represented by both error bars and shaded bands. Lower logMAR values indicate better acuity.
The estimated mean CDVA was −0.0504 logMAR at 3 months and −0.0449 logMAR at 12 months. The change was +0.0055 logMAR (95% CI −0.0010 to +0.0119; Holm-adjusted p = 0.190). Model-based unadjusted p-values were 0.029 for UDVA and 0.034 for CDVA, but neither remained significant after correction across the five outcomes (both adjusted p = 0.086). Cluster-based unadjusted p-values were 0.058 and 0.095, respectively. Thus, inference concerning these small changes depended on the covariance estimator and multiplicity correction (Table S2).

3.4. Covariate-Adjusted Analyses

The correlation between K1 and K2 was 0.934, and that between axial length and IOL power was −0.850. Replacing K1 and K2 with mean keratometry and corneal astigmatism, and using the axial length or IOL power in separate models, reduced the maximum variance inflation factors to 2.38 and 1.78, respectively. None of the 60 demographic/biometric visit-interaction tests remained significant after false discovery rate adjustment (Table S3). These exploratory associations were not interpreted as validated predictors of postoperative outcome.
The independent patient-mean paired analysis estimated a SEQ change of +0.104 D (95% CI +0.078 to +0.131). Restriction to 267 recorded complementary pairs gave +0.104 D (95% CI +0.077 to +0.131; adjusted p < 0.001). Within those patients, the Plus-minus-MID difference in SEQ change was +0.016 D (95% CI −0.029 to +0.060; adjusted p = 1.000), consistent with the interaction model. Analyses restricted to patients with observed baseline UDVA yielded the same qualitative conclusions for the principal refractive shifts.
All 30 retained mixed models converged with finite likelihoods and valid fixed-effect covariance estimates. Some variance components were close to the parameter boundary, particularly the additional eye-level CDVA variance. Residual distributions showed discrete measurement patterns and departures in the tails. These findings support retaining the cluster-based and paired sensitivity analyses alongside the working mixed-model estimates; convergence alone does not establish exact distributional assumptions.

4. Discussion

This analysis identifies small but statistically detectable hyperopic shifts between the recorded 3- and 12-month visits after bilateral Artis Symbiose implantation. The mean SEQ increase of approximately +0.10 D was supported by postoperative-only nested models, patient-cluster inference and an independent paired analysis. Cylinder and distance-acuity changes were smaller and were not significant after multiplicity adjustment. The revised findings therefore support a qualified account of postoperative stability: limited average change coexisted with a detectable refractive shift and appreciable variation between individual eyes.

4.1. Longitudinal Stability of Refractive Outcomes

Early postoperative stabilisation after uncomplicated cataract surgery [1,2,3,4,5] does not imply that subsequent mean change must be exactly zero. Our postoperative-only analysis separates the much greater preoperative refractive variability from the variance relevant to the principal follow-up contrast. This distinction materially narrows the confidence intervals and changes the interpretation of the sphere and SEQ findings. Effective lens position, capsular bag behaviour and corneal changes are plausible mechanisms discussed in prior studies [6,7], but the present dataset contains no serial anatomical measurements with which to distinguish them.
The mean SEQ shift fell within the ±0.25 D margin, and exploratory TOST supported mean changes within both SEQ margins. These tests answer a different question from testing a zero mean difference and cannot retroactively confer a prospectively specified equivalence design [17]. Individual-eye change remains essential to interpretation: approximately one-quarter of eyes exceeded 0.25 D, and 5.4% exceeded 0.50 D. The accompanying reduction in the proportion within ±0.50 D of emmetropia further illustrates why a small mean shift should not be equated with unchanged refractive accuracy in every eye. Comparisons with previous 6–12-month multifocal IOL studies [8,9,10,11,20] should account for their populations, endpoints and covariance assumptions. A mean shift below a conventional 0.25 D refraction step can arise through averaging changes across eyes; statistical detection does not establish that an individual eye’s change exceeds measurement variability. In addition, SEQ combines sphere and half the cylinder, so quarter-dioptre-component increments can produce 0.125 D SEQ increments. The absence of repeatability measurements limits separation of small true changes from measurement variability.

4.2. Visual Acuity Stability and Performance of Complementary IOLs

The estimated UDVA change was less than 0.01 logMAR, and its confidence interval remained within the exploratory ±0.05 logMAR margin. CDVA was already high before surgery, limiting the scope for further improvement and making ceiling effects relevant to the interpretation of small subsequent changes. The inclusion of refractive lens exchange also limits comparison with cohorts defined by visually significant cataracts. The observed outcomes should therefore be interpreted within this selected population rather than as evidence that the same results apply across cataract severities.
Complementary multifocal systems are intended to support binocular function across distances, as reflected in prior Artis Symbiose evaluations [12,13,14] and broader binocular strategy research [21]. Our principal conclusions concern refraction and high-contrast distance acuity. Contrast sensitivity, dysphotopsia, defocus performance, posterior capsule opacity and patient satisfaction may change independently of these measures. Experimental work on Nd:YAG-induced pitting in two monofocal IOL models demonstrated changes in light distribution and optical quality [22]; it provides mechanistic context but does not establish clinical deterioration or device-specific susceptibility in Artis Symbiose recipients. On the other hand, the measured endpoints are insufficient to characterise overall optical performance or patients’ perceived quality of vision.

4.3. Covariate-Adjusted Longitudinal Outcomes

The analysis uses visit-by-covariate interactions to assess heterogeneity in postoperative change, without treating unchanged contrasts after adjustment as independent evidence of robustness. In balanced repeated-measures data, additive time-invariant covariates are not expected to materially alter the common within-eye visit contrast. No demographic/biometric interaction survived false discovery rate control, although the analyses do not exclude smaller associations. The greater SEQ shift in toric eyes does not establish a causal effect of toricity, as toric IOL allocation was not randomised. Similarly, a non-significant MID-versus-Plus interaction does not establish equivalence or interchangeability of the two optical designs. Although no toric IOL required realignment, this does not establish rotational stability: quantitative rotation data were unavailable, and the larger SEQ shift cannot be attributed to rotation.

4.4. Study Context and Limitations

The retrospective single-centre design and requirement for complete primary postoperative data restrict generalisability. Incomplete information on the eligible surgical population, exclusions and exact follow-up dates precluded estimation of population follow-up rates and assessment of adherence to scheduled visit windows. Eligibility restrictions concerning ocular comorbidity and postoperative complications limit generalisability. One patient underwent bilateral Nd:YAG capsulotomy between visits and remains represented in the reported analyses; the effect of excluding this patient has not been assessed. Baseline UDVA was missing at the patient level and was associated with observable demographic and biometric differences; a missing-at-random assumption is therefore unsupported. The primary postoperative analysis retains these patients but remains vulnerable to selection bias from requiring complete postoperative follow-up.
Indication-specific counts were unavailable, preventing separate assessment of cataract surgery and refractive lens exchange. Surgeon effects were not assessed; consequently, the extent to which individual surgeons may have influenced the observed outcome warrants future investigation. The absence of quantitative toric rotation measurements precluded assessment of rotational stability or its relationship to refractive change. Prediction error summaries were available for 553 eyes, but formula-specific comparisons were not undertaken. The manufacturer-recommended IOL constants were used, and no surgeon- or centre-specific optimisation of these constants was performed. Unmeasured illuminance and incomplete documentation of refraction endpoint criteria further limit interpretation of small changes.
Defocus curves, contrast sensitivity, dysphotopsia and patient-reported satisfaction were not evaluated in this longitudinal analysis. Some participants are likely to overlap with the earlier cohort reported in [12]; the extent of overlap could not be established. The earlier study recruited patients between April 2021 and May 2022 [12], within the April 2021–December 2025 surgical period of the present study. The present study should therefore not be regarded as independent validation of that cohort. Its additional contribution is the explicit modelling of postoperative change, fellow-eye clustering, individual-eye thresholds and recorded lens/toricity interactions. Follow-up beyond the recorded 12-month assessment remains necessary to characterise longer-term outcomes.

5. Conclusions

Among selected patients with complete postoperative data, bilateral Artis Symbiose implantation was followed by small, statistically detectable hyperopic shifts in sphere and SEQ between the recorded 3- and 12-month visits. Mean changes in SEQ and UDVA fell within the margins used for exploratory equivalence testing, although changes varied more widely across individual eyes. These findings support limited average refractive and distance-acuity change over the observed interval; they do not establish stability in every eye, equivalence between lens designs or comprehensive functional stability. Prospective studies with complete documentation of follow-up timing and more comprehensive assessments of visual function are warranted.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/medsci14080820/s1: Table S1. Fixed-effect estimates from the postoperative-only primary models; Table S2. Sensitivity of the postoperative contrasts to the inferential method and cohort; Table S3a. Visit-by-covariate interactions in the axial length specification: refraction; Table S3b. Visit-by-covariate interactions in the axial length specification: distance visual acuity; Table S3c. Visit-by-covariate interactions in the IOL power specification: refraction; Table S3d. Visit-by-covariate interactions in the IOL power specification: distance visual acuity; Table S4. Baseline characteristics by availability of preoperative UDVA.

Author Contributions

Conceptualisation, S.M., R.N.M. and J.E.M.; methodology, S.M. and J.E.M.; formal analysis, R.N.M., S.M., B.C., R.C., S.S. and N.M.; data curation, R.N.M. and S.M.; writing—original draft preparation, R.N.M., S.M., B.C., R.C. and S.S.; writing—review and editing, R.N.M., S.M., B.C., R.C., S.S., N.M. and J.E.M.; funding acquisition, S.M. and J.E.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Academy of Medical Sciences through the Cross-Sector Experience Awards [CSEA002/1021] and the Engineering and Physical Sciences Research Council through the Health Technologies Connectivity Awards [APP51965].

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and received ethical approval under reference CECREC26-11 from the Cathedral Eye Clinic Research and Ethic Committee (1 April 2021).

Data Availability Statement

The anonymised data supporting the findings of this study are available from the corresponding author upon reasonable request, subject to applicable ethical and data protection requirements.

Acknowledgments

The authors gratefully acknowledge the support of the funders.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. de Juan, V.; Herreras, J.M.; Pérez, I.; Morejón, Á.; Río-Cristóbal, A.; Martín, R.; Fernández, I.; Rodríguez, G. Refractive stabilization and corneal swelling after cataract surgery. Optom. Vis. Sci. 2013, 90, 31–36, Erratum in: Optom. Vis. Sci. 2013, 90, e134. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Caglar, C.; Batur, M.; Eser, E.; Demir, H.; Yaşar, T. The stabilization time of ocular measurements after cataract surgery. Semin Ophthalmol. 2017, 32, 412–417. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Ostri, C.; Holfort, S.K.; Fich, M.S.; Riise, P. Automated refraction is stable 1 week after uncomplicated cataract surgery. Acta Ophthalmol. 2018, 96, 149–153. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Charlesworth, E.; Alderson, A.J.; de Juan, V.; Elliott, D.B. When is refraction stable following routine cataract surgery? A systematic review and meta-analysis. Ophthalmic Physiol. Opt. 2020, 40, 531–539. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Feng, R.; Wang, M.; Tao, S.; Liang, F.; Liu, X.; He, C.; Fan, S. Refractive stability and timing of spectacle prescription following cataract surgery in myopic eyes. Ophthalmic Physiol. Opt. 2024, 44, 576–583. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Schmickler, S. Postoperative changes in refraction and anterior chamber depth in different multifocal intraocular lenses. J. Refract Surg. 2008, 24, 306–308. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Jeon, J.H.; Tyler, R.H.T.; Seo, K.Y.; Kim, E.K.; Kim, T.I. Comparison of refractive stability after non-toric versus toric intraocular lens implantation during cataract surgery. Am. J. Ophthalmol. 2014, 157, 658–665.e1. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Lubiński, W.; Gronkowska-Serafin, J.; Podborączyńska-Jodko, K.; Karczewicz, D. Cataract surgery with bilateral multifocal ReZoom intraocular lens implantation—Comparison of 3- and 12-months follow-up. Klin. Ocz. 2009, 111, 327–331. [Google Scholar]
  9. Cezón Prieto, J.; Bautista, M.J. Visual outcomes after implantation of a refractive multifocal intraocular lens with a +3.00 D addition. J. Cataract Refract Surg. 2010, 36, 1508–1516. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Baykara, M.; Akova, Y.A.; Arslan, O.S.; Cinhuseyinoglu, N.; Takmaz, T.; Gucukoglu, A.; Usta, Y.B. Visual outcomes at 12 months in patients following implantation of a diffractive multifocal intraocular lens. Ophthalmol. Ther. 2015, 4, 21–32. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Bianchi, G.R. Spectacle independence after cataract surgery: A prospective study with a multifocal intraocular lens. Med. Hypothesis Discov. Innov. Ophthalmol. 2020, 9, 38–46. [Google Scholar] [PubMed]
  12. McNeely, R.N.; Stewart, S.A.; Moore, J.E. Visual performance and subjective experience 3 months and 12 months after combined implantation of 2 new complementary continuous phase multifocal intraocular lenses. J. Cataract Refract Surg. 2023, 49, 921–928. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Lajara-Blesa, J.; Rodríguez-Izquierdo, M.A.; Vallés-San-Leandro, L.; Jutley, G.; Ortega-García, M.D.R.; Zapata-Díaz, J.F. Standard clinical outcomes, light distortion, stereopsis, and a quality-of-life assessment of a new binocular system of complementary IOLs. J. Refract Surg. 2023, 39, 654–661. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Le Dinahet, J.; Benyoussef, A.-A.; Cochener-Lamard, B. Visual outcomes after implantation of a presbyopia-correcting IOL that combines extended depth-of-focus and progressive phase complementarity optics. J. Fr. Ophtalmol. 2026, 49, 104770. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Laird, N.M.; Ware, J.H. Random-effects models for longitudinal data. Biometrics 1982, 38, 963–974. [Google Scholar] [CrossRef] [Scilit]
  16. Lindstrom, M.J.; Bates, D.M. Newton–Raphson and EM algorithms for linear mixed-effects models for repeated-measures data. J. Am. Stat. Assoc. 1988, 83, 1014–1022. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Lakens, D. Equivalence tests: A practical primer for t tests, correlations, and meta-analyses. Soc. Psychol. Personal. Sci. 2017, 8, 355–362. [Google Scholar] [PubMed]
  18. Holm, S. A simple sequentially rejective multiple test procedure. Scand. J. Stat. 1979, 6, 65–70. [Google Scholar]
  19. Benjamini, Y.; Hochberg, Y. Controlling the false discovery rate: A practical and powerful approach to multiple testing. J. R Stat. Soc. Ser. B Stat. Methodol. 1995, 57, 289–300. [Google Scholar] [CrossRef] [Scilit]
  20. McNeely, R.N.; Pazo, E.; Spence, A.; Richoz, O.; Nesbit, M.A.; Moore, T.C.B.; Moore, J.E. Visual outcomes and patient satisfaction 3 and 12 months after implantation of a refractive rotationally asymmetric multifocal intraocular lens. J. Cataract Refract Surg. 2017, 43, 633–638. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Naujokaitis, T.; Łabuz, G.; Khoramnia, R.; Auffarth, G.U. Review of Mix-and-Match Approach and Binocular Intraocular Lens Systems. J. Clin. Med. 2025, 14, 4263. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. De Luca, L.; Menna, F.; Lupo, S.; Ruello, E.; Testagrossa, B.; Acri, G.; Carlà, M.M.; Baldascino, A.; Vingolo, E.M.; Aragona, P.; et al. Optical quality degradation following Nd:YAG laser-induced intraocular lens pitting: A multimodal experimental study. Vision 2026, 10, 54. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.