Reviewer 1 Report
Comments and Suggestions for AuthorsThis is an excellent scoping review of a very important subject.
I thinkthe key deficiency, which leaves readers wondering about the next steps is to provided a detailed critical report of what has been accomplished in hospitals (including operating theatres) and how that technology can be transferred to nursing homes. Secondly there is an emerging literature on robotic methods of videoing hospital cleaners and feeding back to them immediately if their cleaning is effective and following the rules. I would like these two areas to be reviewed critically in detail and the application to nursing homes set out in detail otherwise administrators and staff in nursing homes are left to their own devices.
There are two important systematic reviews and meta-analyses of hospital cleaning published in the Journal of Hospital Infection since 2022.
Lets make this a widely cited article!
Author Response
1.1 I think the key deficiency, which leaves readers wondering about the next steps is to provided a detailed critical report of what has been accomplished in hospitals (including operating theatres) and how that technology can be transferred to nursing homes.
We thank the reviewer for this insightful suggestion. In response, we have expanded the Discussion (section 4.8) to provide a more detailed critical review on environmental disinfection technologies adopted in hospitals and operating theatres. Critical discussion of the extent to which disinfection technologies from hospitals can be transferred to LTCFs has already been included in the original manuscript.
1.2 Secondly there is an emerging literature on robotic methods of videoing hospital cleaners and feeding back to them immediately if their cleaning is effective and following the rules. I would like these two areas to be reviewed critically in detail and the application to nursing homes set out in detail otherwise administrators and staff in nursing homes are left to their own devices.
We agree that monitoring and auditing environmental cleaning are highly relevant. We have therefore added a paragraph in the Discussion (section 4.1) summarising the hospital literature on automated and video-based cleaning feedback systems. We also discuss potential applications and limitations of such systems in LTCFs, including privacy concerns and resource constraints.
1.3 There are two important systematic reviews and meta-analyses of hospital cleaning published in the Journal of Hospital Infection since 2022.
We thank the reviewer for highlighting these important systematic reviews and meta-analyses. We believe you are referring to the following two papers on hospital environmental cleaning published in Journal of Hospital Infection.
- Thomas RE. “Cleaning and disinfecting surfaces in hospitals and long‑term care facilities for reducing hospital‑ and facility‑acquired bacterial and viral infections: a systematic review.” Journal of Hospital Infection 2022;122:9–26.
- Thomas RE, Thomas BC, Lorenzetti D, Conly J. “Hospital and long-term care facility environmental service workers' training, skills, activities and effectiveness in cleaning and disinfection: a systematic review”. J Hosp Infect. 2022 Jun;124:56-66.
We have revised the Discussion (section 4.8) to briefly summarise their main findings and to situate our LTCF-focused scoping review within this broader evidence base.
Reviewer 2 Report
Comments and Suggestions for AuthorsThe manuscript entitled “Environmental disinfection in long-term care facilities – A scoping review” was reviewed.
Authors offered rare applied new no-touch automated disinfection technologies on long-term care facility (LTCF) residents where these technologies represent supplements to standard infection prevention control clumps to decrease environmental contamination in LTCFs. They monitored 316 records satisfying inclusion parameters and exposed to diverse physical and chemical disinfection approaches. In study design, authors are guided by the Population-Concept-Context (PCC) framework to define the scope, including observational and experimental studies published between 2021/01/01 and 2026/01/01 on the effect of environmental disinfection, carried out in long-term care facilities or nursing homes and inclusion criteria by searching database of PubMed and Medline. This is a well-structured and informative review. Here are some minor suggestions/revisions that support the valuability of this manuscript.
My opinion regarding quality, originality, clearance, suitability of study design, and compatibility of the outputs with the aims of the study is marked in the journal reviewing platform.
Despite that Materials and Methods section is clear, I suggest, if possible, to present it as a flowchart added to the existing form.
Increase the number of keywords to 5.
Lines 68, 69, and 70: make “(MRSA)”, “(VRE)”, “spp.”, “and” in non-italic format.
Line 72: Revise ≥3-log10
Appendix format should follow the journal guidelines.
References list should follow the journal guidelines.
Author Response
Authors offered rare applied new no-touch automated disinfection technologies on long-term care facility (LTCF) residents where these technologies represent supplements to standard infection prevention control clumps to decrease environmental contamination in LTCFs. They monitored 316 records satisfying inclusion parameters and exposed to diverse physical and chemical disinfection approaches. In study design, authors are guided by the Population-Concept-Context (PCC) framework to define the scope, including observational and experimental studies published between 2021/01/01 and 2026/01/01 on the effect of environmental disinfection, carried out in long-term care facilities or nursing homes and inclusion criteria by searching database of PubMed and Medline. This is a well-structured and informative review. Here are some minor suggestions/revisions that support the valuability of this manuscript.
My opinion regarding quality, originality, clearance, suitability of study design, and compatibility of the outputs with the aims of the study is marked in the journal reviewing platform.
2.1 Despite that Materials and Methods section is clear, I suggest, if possible, to present it as a flowchart added to the existing form.
We appreciate this suggestion. A PRISMA flowchart has been supplemented in supplementary materials.
2.2 Increase the number of keywords to 5.
We appreciate this suggestion. We have increased the number of keywords to five.
2.3 Lines 68, 69, and 70: make “(MRSA)”, “(VRE)”, “spp.”, “and” in non-italic format.
Thank you for pointing this out. We have corrected the formatting.
2.4 Line 72: Revise ≥3-log10
We agree that the expression “≥3‑log10” may be unclear to some readers. We have revised the text to express these reductions in percentage terms (e.g. “≥99.9% reduction”) for greater clarity.
2.5 Appendix format should follow the journal guidelines.
We thank reviewer’s reminding. We have revised the format of supplementary materials based on the requirements of journal.
2.6 References list should follow the journal guidelines.
Thank you for pointing this out. The reference list has been revised as ASC style based on the journal guidelines.
Reviewer 3 Report
Comments and Suggestions for AuthorsThis manuscript reviews data focused on infection prevention in long-term healthcare facilities. Initially, a fairly large dataset was obtained, but specific focus on LTCF was limited to seven datasets. The authors acknowledge this limitation, but assert that there is no previous review of even this limited information. Their conclusions are expressed with an appropriate amount of reservation owing to the limited data and the variations within the datasets available. As such, the manuscript seems appropriate for publication.
There are a few points noted following that the Authors and Editor may wish to consider prior to publication. As a general comment, the English is fine.
Issues
· The authors us the terminology 2-log10 and 3-log10. This may be a common representation in this art, but it does not make mathematical sense. I expect the expression to be 2-log10x, with the value of x specified or ranged. I think expressing these values as percentage decreases would be clearer to most readers. (See lines 242ff)
· The use of the terms "terminal cleaning" (line 75) and "terminal disinfection" (line 87) is unclear. Do the authors mean complete disinfection? If they mean that the method is effective in reducing the contamination of various organisms to an undetectable level, I think it would be better to state that. I think the use of the term terminal in a hospital or LTCF facility has an unfortunate connotation.
· I don't think "HAI" is defined before it is used. This should be done even though the abbreviation will be obvious to most readers.
· I think that the statement "There was no language limitation in this review." I assume that the authors mean that data were not limited to publications in any particular language. I think the authors should indicate how translations were obtained if any was required. If no translation was required, this should be stated.
· Section 2.2. Was the term "long term HEALTHcare facilities" searched?
· Tables 1 and 2 should be included within the text at the places at which they are introduced.
· Were the two DHP studies conducted at the same vapor concentrations? (l 214) Is line 302 the answer?
· What exactly is a "quasi-experimental design" (l 358) Is it flawed or not well described or something else?
· Would it not be useful to briefly exemplify the "heterogeneous and surrogate endpoints" to better characterise their disqualification? (l 412)
· I think the phrase "leading to the truth" should be changed to "leading to the conclusion" (l 457)
Author Response
This manuscript reviews data focused on infection prevention in long-term healthcare facilities. Initially, a fairly large dataset was obtained, but specific focus on LTCF was limited to seven datasets. The authors acknowledge this limitation, but assert that there is no previous review of even this limited information. Their conclusions are expressed with an appropriate amount of reservation owing to the limited data and the variations within the datasets available. As such, the manuscript seems appropriate for publication.
There are a few points noted following that the Authors and Editor may wish to consider prior to publication. As a general comment, the English is fine.
3.1 The authors us the terminology 2-log10 and 3-log10. This may be a common representation in this art, but it does not make mathematical sense. I expect the expression to be 2-log10x, with the value of x specified or ranged. I think expressing these values as percentage decreases would be clearer to most readers. (See lines 242ff)
We agree that the expression “≥3‑log10” may be unclear to some readers. We have revised the text to express these reductions in percentage terms (e.g. “≥99.9% reduction”) for greater clarity.
3.2 The use of the terms "terminal cleaning" (line 75) and “terminal disinfection" (line 87) is unclear. Do the authors mean complete disinfection? If they mean that the method is effective in reducing the contamination of various organisms to an undetectable level, I think it would be better to state that. I think the use of the term terminal in a hospital or LTCF facility has an unfortunate connotation.
We thank the reviewer for highlighting the potential ambiguity of the term. In the revised manuscript, we have clarified that “terminal cleaning/disinfection” refers to whole‑room cleaning and disinfection performed after patient or resident discharge (or at the end of an occupancy period), with the aim of reducing environmental contamination to very low or undetectable levels prior to the next occupant.
3.3 I don't think "HAI" is defined before it is used. This should be done even though the abbreviation will be obvious to most readers.
We appreciate this suggestion. We have now defined the abbreviation “HAI” (healthcare‑associated infection) at its first occurrence in the text.
3.4 I think that the statement "There was no language limitation in this review." I assume that the authors mean that data were not limited to publications in any particular language. I think the authors should indicate how translations were obtained if any was required. If no translation was required, this should be stated.
We thank the reviewer for this helpful clarification. We have revised the Methods (section 2.1) to make our approach explicit.
3.5 Section 2.2. Was the term "long term HEALTHcare facilities" searched?
We thank the reviewer for this supplement. We have revised the Methods (section 2.1) to make our approach explicit. Additional searching terms have been applied including "long term HEALTHcare facilities".
3.6 Tables 1 and 2 should be included within the text at the places at which they are introduced.
We thank the reviewer for this practical suggestion. In the revised manuscript, we have repositioned Tables 1 and 2 so that Table 1 now appears immediately after it is first mentioned in section 3.1 (Study selection and characteristics), and Table 2 appears immediately after its first mention in section 4.2 (General overview of no‑touch environmental disinfection methods). This should make it easier for readers to interpret the tables alongside the corresponding text.
3.7 Were the two DHP studies conducted at the same vapor concentrations? (l 214) Is line 302 the answer?
In Cole 2023’s study, they didn’t reported the specific concentration of DHP applied, but mentioned “The DHP concentration generated by the units falls well below the 1 part per million (ppm) human exposure safety threshold”, while in 2025’s study, they reported an estimated equilibrium concentration of 2 parts per billion of DHP used, which is consistently lower the 1 part per million (ppm) they mentioned in the 2023’s study. We have also added this information in table 1 for supplement.
3.8 What exactly is a "quasi-experimental design" (l 358) Is it flawed or not well described or something else?
We agree that the term “quasi‑experimental design” can be interpreted in different ways. In this manuscript, we use it to describe non‑randomised intervention studies (e.g. before–after studies, interrupted time series, or controlled studies without random allocation) that implement an environmental disinfection intervention and compare outcomes over time or between groups, but do not use individual‑ or cluster‑level randomisation. We have added a brief clarifying sentence in the Methods/Discussion to make this definition explicit.
3.9 Would it not be useful to briefly exemplify the "heterogeneous and surrogate endpoints" to better characterise their disqualification? (l 412)
We thank the reviewer’s suggestion, we have provide examples in section of “4.7. Choice of Study Endpoints” to characterise the heterogeneous of such endpoints.
3.10 I think the phrase "leading to the truth" should be changed to "leading to the conclusion" (l 457)
We thank the reviewer for this phrasing suggestion. We have replaced “leading to the truth” with “leading to the conclusion” as recommended.
Reviewer 4 Report
Comments and Suggestions for AuthorsThe manuscript, titled "Environmental disinfection in long-term care facilities – A scoping review," addresses an important gap in the literature that warrants our attention.
The limited number of included studies is striking. Including only seven studies is a significant vulnerability that constrains the robustness of the conclusions. Although the scope of Long-Term Care Facilities (LTCFs) is indeed challenging, this low number suggests a possible flaw in the search strategy or excessively restrictive inclusion criteria.
Suggestion: Re-evaluate your search terms. The current search appears to have focused strictly on terms such as "nursing home" and "long-term care." Consider expanding to include synonyms or related terms, such as "assisted living," "skilled nursing," "residential aged care," or "geriatric care facilities." Furthermore, consider extending the search period or including grey literature (technical reports, government guidelines not published in peer-reviewed journals, but of epidemiological relevance) to broaden the evidence base.
The justification for exclusions needs more detailed explanation; the 75% exclusion rate (22/29) makes this quite apparent. This high rate indicates that the eligibility criteria may be too rigid or that the initial screening (title/abstract) was not sufficiently precise, resulting in noise in the final phase. I suggest that the PRISMA flow diagram detail the reasons for exclusion in a more granular way. If many articles were excluded for being "unrelated to environmental disinfection," verify whether there was an overly narrow interpretation of what constitutes "environmental disinfection" (e.g., interventions focusing on air vs. surfaces). Clearly justify why these articles, despite their similarities, do not fall within the study's scope.
Another point of concern is the "database limitation." Why did the authors limit themselves to only two databases? Since a scoping review aims to map knowledge, this limitation is a weakness when it should, in fact, be a strength of the review. Therefore, it is mandatory to include other databases such as EMBASE, CINAHL, Web of Science, or Scopus. Including these bases will significantly expand the number of results and mitigate the bias of a "Western-Centric" search, as mentioned in section 4.10.2 of the manuscript.
Suggestions for overall text improvement:
Standardization of Outcomes: The manuscript correctly points out that outcomes are heterogeneous. I recommend creating a more robust summary table (expanding Table 1) that explicitly relates the intervention used to the primary clinical outcome observed. This will help the reader better visualize the correlation, even if statistically weak, between disinfection and the reduction of infections.
Focus on "Implementation": As this is a scoping review intended to guide future studies, deepen the section on barriers. The difficulties of implementation in LTCFs (cost, training, homelike infrastructure) are as important as microbial efficacy.
Discussion: The discussion should more vigorously contrast findings in LTCFs versus hospitals. The manuscript already touches on this, but it could be more emphatic about how the already robust hospital literature can—or cannot—be adapted to the reality of the lower density and high heterogeneity of LTCFs.
Comments for author File:
Comments.pdf
Author Response
The manuscript, titled "Environmental disinfection in long-term care facilities – A scoping review," addresses an important gap in the literature that warrants our attention.
The limited number of included studies is striking. Including only seven studies is a significant vulnerability that constrains the robustness of the conclusions. Although the scope of Long-Term Care Facilities (LTCFs) is indeed challenging, this low number suggests a possible flaw in the search strategy or excessively restrictive inclusion criteria.
Suggestion:
4.1 Re-evaluate your search terms. The current search appears to have focused strictly on terms such as "nursing home" and "long-term care." Consider expanding to include synonyms or related terms, such as "assisted living," "skilled nursing," "residential aged care," or "geriatric care facilities." Furthermore, consider extending the search period or including grey literature (technical reports, government guidelines not published in peer-reviewed journals, but of epidemiological relevance) to broaden the evidence base.
We thank for reviewer’s suggestion. We have expanded our searching strategies terms and also expanded the search period from 2021/01/01 - 2026/01/01 to 2021/01/01 - 2026/05/02. Full text of searching strategies was added in supplementary materials.
4.2 The justification for exclusions needs more detailed explanation; the 75% exclusion rate (22/29) makes this quite apparent. This high rate indicates that the eligibility criteria may be too rigid or that the initial screening (title/abstract) was not sufficiently precise, resulting in noise in the final phase. I suggest that the PRISMA flow diagram detail the reasons for exclusion in a more granular way. If many articles were excluded for being "unrelated to environmental disinfection," verify whether there was an overly narrow interpretation of what constitutes "environmental disinfection" (e.g., interventions focusing on air vs. surfaces). Clearly justify why these articles, despite their similarities, do not fall within the study's scope.
We thank reviewer’s suggestion. The PRISMA flow chart with detailed exclusion reasons has been supplemented.
4.3 Another point of concern is the "database limitation." Why did the authors limit themselves to only two databases? Since a scoping review aims to map knowledge, this limitation is a weakness when it should, in fact, be a strength of the review. Therefore, it is mandatory to include other databases such as EMBASE, CINAHL, Web of Science, or Scopus. Including these bases will significantly expand the number of results and mitigate the bias of a "Western-Centric" search, as mentioned in section 4.10.2 of the manuscript.
Thanks for reviewer’s suggestion. We have searched above additional Embase, CINAHL and Scopus databases to identify more potential studies. Details have been added in the revised method section.
Suggestions for overall text improvement:
4.4 Standardization of Outcomes: The manuscript correctly points out that outcomes are heterogeneous. I recommend creating a more robust summary table (expanding Table 1) that explicitly relates the intervention used to the primary clinical outcome observed. This will help the reader better visualize the correlation, even if statistically weak, between disinfection and the reduction of infections.
We thank for reviewer’s suggestion. The expanded table 1 added with primary clinic outcomes have been incorporated in the manuscript. The Effect of such interventions on clinical infection were also listed in one column for a better understanding for reader.
4.5 Focus on "Implementation": As this is a scoping review intended to guide future studies, deepen the section on barriers. The difficulties of implementation in LTCFs (cost, training, homelike infrastructure) are as important as microbial efficacy.
We agree that implementation considerations are critical for LTCFs. In the revised Discussion (sections 4.9), we have expanded our description of barriers and facilitators, including practical issues such as capital and running costs, staff training and turnover, integration with existing cleaning workflows, infrastructural constraints (HVAC capacity, room layout), and the need to preserve a homelike environment for residents.
4.6 Discussion: The discussion should more vigorously contrast findings in LTCFs versus hospitals. The manuscript already touches on this, but it could be more emphatic about how the already robust hospital literature can—or cannot—be adapted to the reality of the lower density and high heterogeneity of LTCFs.
We thank the reviewer for this helpful suggestion. In the revised Discussion (section 4.8), we now more explicitly contrast environmental disinfection in LTCFs with the much larger hospital and operating‑theatre literature. We summarise key hospital evidence, including systematic reviews by Carling et al. and Chau et al. and studies of high‑efficiency ventilation, HEPA, UVGI, UV‑C and hydrogen peroxide vapour systems, which have demonstrated substantial reductions in environmental contamination and decreases in infections such as C. difficile, MRSA and VRE. We then clarify why these findings cannot be directly extrapolated to LTCFs, highlighting differences in infrastructure, staffing levels and turnover, financial resources, continuous occupancy of resident rooms, homelike layouts with extensive personal belongings, and the frailty and cognitive impairment of LTCF residents. These additions make clearer which elements of the hospital literature provide proof‑of‑concept and which require LTCF‑specific adaptation and evaluation.
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThis is an excellent and precise contribution to the literature. The authors have added text which responds to all my suggestions about assessing study designs, careful assessment of risk of bias and alternative methods of cleaning, robotic observation and coaching of cleaners.
Reviewer 4 Report
Comments and Suggestions for AuthorsThe authors have substantially improved the presentation of the work, but they have not resolved the study’s main scientific limitation. The manuscript is better written, methodologically more transparent, and formally addresses most of the reviewers’ comments. Nevertheless, the central issue remains: the available body of evidence is still extremely small and weak to support robust conclusions.
The literature search was expanded to include additional databases; however, only seven studies were ultimately included. Either the topic truly has very limited literature, or the search strategy remains excessively restrictive. Given that the authors identified 505 studies in PubMed, 242 in Embase, 198 in CINAHL, and 460 in Scopus (a total of 1,405 records), yet only seven met the eligibility criteria, it appears that the inclusion criteria may still be overly restrictive.
The authors have fully addressed the PRISMA flow diagram concerns. The detailed reporting of exclusion reasons, both in the text and in the flowchart, improves methodological transparency. Table 1 has been substantially improved, the implementation discussion is more useful from a practical perspective, and the comparison between LTCFs and hospitals is conceptually much more mature.
However, the manuscript’s primary limitation persists. Despite all revisions, only seven studies were included (one RCT), the vast majority are observational, and there is considerable heterogeneity in both interventions and outcomes. Consequently, there is little meaningful comparability among the included studies.
Furthermore, the stated focus of the manuscript is “environmental disinfection in LTCFs,” yet approximately half of the included studies evaluate HVAC systems, air purification technologies, or UVGI-based ventilation interventions. This creates a conceptual overlap between surface environmental disinfection and air quality control. While these areas are clearly related, they are not equivalent.
The following questions therefore remain insufficiently addressed:
-
What is the operational definition of “environmental disinfection” adopted in this review?
-
Why were air-based and surface-based interventions grouped together within the same analytical framework?
In addition, several studies included in Table 1 are methodologically weak:
-
Cole et al. (2025): three units, no randomization (essentially an observational outbreak report);
-
Urrutia et al. (2023): one LTCF, before-and-after design without a robust control group;
-
Cole et al. (2023): one LTCF, microbiological outcomes only, with no clinical infection endpoints.
If these three studies are excluded, only four studies remain. This is an extremely limited evidence base from which to draw any meaningful conclusions.
The legitimate interpretation is that there is currently very little high-quality scientific literature on this topic, and therefore the study functions primarily as a mapping of the current state of the literature. While this has value, it does not support strong conclusions regarding the effectiveness of environmental disinfection technologies in LTCFs.