Abstract
Green building material (GBM) certification is intended to reduce information asymmetry, but its price effect under mandatory-use rules is unclear. This exploratory multi-material case study examined whether Taiwan’s GBM label was associated with posted price differentials in the list prices and quotations of three purposively selected suppliers. Tiles (primary evidence): for recycled-label ceramic tiles counted toward the usage-rate requirement (206 stock-keeping units), 27 of 28 within-series matched pairs had identical list prices; the cross-sectional hedonic label premium was −0.95% (90% confidence interval: −4.02% to 2.26%), against quality-grade premiums of 11.0–60.3%, whereas a series fixed-effects model gave +2.75% (0.11% to 5.49%), consistent with selective certification of larger formats. Concrete (descriptive only): recycled-label low-carbon concrete, which is not counted toward the requirement, was priced identically to Portland cement concrete under a supplier-set promotional quotation. Coatings (exploratory): healthy-label coatings with recycled silica powder, also counted toward the requirement, were not priced higher. No substantial label premium was found in these suppliers’ listed prices and promotional quotations; this posted-price parity does not imply transaction-price or total procurement-cost parity and cannot be extrapolated to the Taiwan market. The design cannot distinguish a pooling equilibrium from low certification costs, input-cost savings, uniform pricing, or buyer indifference.
1. Introduction
The building sector accounts for more than one-third of global energy-related greenhouse gas emissions. As operational energy efficiency continues to improve, embodied carbon arising from the production, transport, and installation of construction materials represents a growing share of whole-life emissions and has become a central challenge for net-zero buildings [1]. Cement and concrete are the principal targets of material decarbonization because of their sheer production volume and the process emissions associated with clinker calcination; established measures, such as partial clinker substitution with pozzolans or ground granulated blast-furnace slag, can substantially reduce the carbon intensity of concrete without major changes to construction practice [2,3]. Taiwan’s 2050 net-zero pathway, published in 2022, identifies building-sector decarbonization and the promotion of low-carbon materials as key strategies [4], making the institutional design of instruments that accelerate the market uptake of low-carbon and healthy materials a shared concern of policymakers and industry.
The construction sector is also central to the United Nations 2030 Agenda for Sustainable Development [5]. Material choices directly affect Sustainable Development Goal (SDG) 12 on responsible consumption and production, including Target 12.5 on substantially reducing waste generation through recycling and reuse and Target 12.7 on promoting sustainable public procurement practices; on Target 9.4 on upgrading industries with clean and environmentally sound technologies; and on SDG 13 on climate action. Mandatory green-material requirements in public works are a direct application of Target 12.7, yet whether such requirements raise the prices of the materials they promote, and hence the fiscal burden of sustainable procurement, has rarely been examined using supplier price data.
Among the available policy instruments, GBM certification is intended to mitigate information asymmetry: buyers rarely observe the health, ecological, or carbon performance of a material at the point of purchase; therefore, third-party certification serves as a signal of quality [6,7,8]. Most jurisdictions incorporate the environmental performance of materials into voluntary green building rating systems, indirectly guiding material selection through credits. Taiwan, by contrast, has adopted a comparatively rare model of direct regulatory mandates. The Architecture and Building Research Institute (ABRI) began accepting applications for the Green Building Material Label in 2004 and had issued more than 4238 labels by 2025 [9]. The label comprises four categories—healthy, ecological, recycled, and high-performance GBMs—addressing the twin objectives of human health and global sustainability. Since 2006, Chapter 17 of the Building Technical Regulations has required buildings for public use (which may be privately owned) and other buildings designated by the Ministry of the Interior to achieve a minimum GBM usage rate for interior finishing materials, initially 5% and progressively raised to the current thresholds of 60% indoors and 20% outdoors [10]. Under this regime, the label is not merely a quality claim but a prerequisite for access to public works and green procurement markets.
This raises a policy-relevant question: Do products carrying the GBM label command different market prices from functionally equivalent non-labeled products? A price premium is consistent with the label being regarded as a credible quality signal and may facilitate cost recovery and provide an incentive for environmental improvement, although these inferences depend on additional assumptions about buyer behavior, cost structures, and competitive conditions. Conversely, price parity is consistent with several explanations, one of which is that the label has shifted from a quality signal to a compliance threshold, eroding its differentiating function. The latter outcome carries a dual implication for net-zero policy: the label would add no label-specific price markup, which facilitates compliance with the mandate; however, it also fails to discriminate between levels of environmental performance and therefore offers little impetus for further low-carbon innovation.
The price effects of green certification have been examined extensively, but predominantly at the building and real estate levels, for example, the capitalization of certification and energy labels into office rents and residential transaction prices [11,12,13,14,15,16]. Research at the material and component levels has focused mainly on cost premiums, adoption barriers, and consumers’ willingness to pay [17,18,19]; studies that test the relationship between material certification and selling prices using manufacturers’ actual pricing data remain scarce. Moreover, existing evidence derives largely from markets with voluntary certification, and whether a label retains its signalling function once certification is legally mandated has yet to be tested empirically.
To address these gaps, this study examines three material categories with distinctly different attributes: ceramic tiles, ready-mixed concrete, and coatings. Exploiting the fact that manufacturers sell labelled and non-labelled versions of otherwise identical products, we employ a matched-pair design within the same firm, series, specification, and grade to reduce confounding by brand, specification, and quality grade, and examine both the list-price differential associated with the label and any differentiated management along the pricing chain. The inferential scope is deliberately narrow: the data are the posted price schedules of three participating suppliers, one per category; therefore, the findings describe listed-price and quotation differentials within these firms rather than transaction prices or the Taiwan market as a whole. Therefore, the study is positioned as a multi-material case study rather than a market-wide test. The three categories also differ in label category and regulatory status: the tiles carry the recycled GBM label and count toward the usage-rate requirement; the coatings carry the healthy GBM label, incorporate recycled silica powder, and also count toward the requirement; and the ready-mixed concrete carries the recycled GBM label but, as a structural material, is not counted toward the usage rate. Because the certification criteria, objectives, and costs of the label categories differ, the results are reported by category and are not generalized across label categories. Within this scope, the study makes three contributions. First, it provides product-level evidence on posted list prices and quotations—rather than transaction prices—under a mandatory material-labelling regime and estimates the implicit price of the label within a hedonic framework, complementing the building-level literature. Because the labelled tiles and concrete carry the recycled GBM label and the certified coatings contain recycled silica powder, this evidence also indicates whether certification makes recycled-content materials more expensive, a question central to circular-economy policy. Second, it sets out signalling-based (pooling equilibrium) and non-signalling explanations of price parity in parallel and specifies the data needed to distinguish them. Third, by including low-carbon concrete, it links the GBM regime to net-zero material policy and derives policy hypotheses on carbon-performance grading for future evaluation.
The remainder of this paper is organized as follows. Section 2 reviews the literature and develops the hypotheses. Section 3 describes the institutional context, data, and methods. Section 4 presents the results for the three material categories. Section 5 discusses the theoretical and policy implications and the limitations of the study, and Section 6 concludes.
2. Literature Review and Hypotheses
2.1. Capitalisation of Green Certification: Building-Level Evidence
The effect of green building certification on property values is among the most consistently documented relationships in real estate economics, with most studies relying on hedonic pricing models [20]. Using a sample of US office buildings, Eichholtz et al. found that LEED- or ENERGY STAR-certified buildings command rents approximately 3% higher per square foot, effective rents approximately 6% higher, and transaction prices approximately 16% higher [11]. Fuerst and McAllister confirmed the coexistence of rental and sale-price premiums for certified buildings using comparable data [12]. Statistically significant positive price effects have also been reported for Green Mark-certified housing in Singapore [13], residential energy labels in the Netherlands [15], green-labelled homes in California [16], energy labels in the Dutch office market [21], and energy performance certificates in England [22].
Green premiums are nevertheless not uniform. Chegut et al. examined the London office market and showed that the premium for certified buildings declines as the local supply of certified space increases [14], indicating that the price effect of certification depends on its scarcity. This finding is directly relevant here: when a label becomes ubiquitous because of a regulatory requirement, its scarcity and discriminating power may diminish, and its price effect may disappear.
2.2. Certification Price Effects at the Product and Material Level
Evidence at the product level is fragmented. Ward et al. found a positive willingness to pay for appliances bearing the ENERGY STAR label [23], and For eco-labels, Teisl et al. showed that the dolphin-safe label influenced the market share of canned tuna in the United States (US) [24]. In the timber market, Kollert and Lagan compared the tender prices of certified and uncertified tropical logs in Sabah, Malaysia, and reported a certification premium that varied by species [25].
Existing research on construction materials has largely adopted a cost perspective, examining the incremental costs of green buildings and materials and the resulting barriers to adoption [17,18,19] or the development and limitations of environmental product declarations (EPDs) in the construction sector [26]. To the best of our knowledge, studies that use manufacturers’ price lists to compare the prices of labelled and non-labelled versions of the same product while controlling for brand, specification, and quality grade remain rare.
The cost side of certified materials also matters for interpreting price comparisons. For cement-based materials, the partial replacement of clinker with supplementary cementitious materials (SCMs), such as ground granulated blast-furnace slag or fly ash, reduces process emissions and, where these by-products are locally available, can lower binder costs relative to clinker [27,28]. In ceramic tile manufacturing, reintroducing fired and unfired tile scrap and other industrial wastes into tile bodies can reduce the consumption of virgin clays and fluxes, although the net cost effect depends on sorting, processing, and quality control requirements [29]. Where a certified product embodies such input savings, equal posted prices for certified and conventional versions do not imply equal unit costs; they may instead imply a larger margin on the certified version. Price parity in posted schedules is therefore a statement about prices, not about costs or margins. On the demand side, research on green and circular public procurement shows that procurement criteria shape which certified products suppliers offer and how they compete in tenders [30,31].
Evidence from Taiwan is limited to the building level and studies of the GBM system itself. Hedonic analyses of residential transactions in New Taipei City found an average premium of approximately 7.5% for EEWH-certified buildings, which did not increase with certification level [32], and the incremental construction cost of upgrading from EEWH Silver to Gold was estimated to be roughly 1–3% [33]. Studies of the GBM system have examined the structure and management of the certified-materials industry [34] and the energy and greenhouse-gas implications of GBM promotion [35]. However, none has examined whether certified materials are priced differently from comparable uncertified products.
2.3. Signalling Theory and Alternative Explanations for Label Price Parity
Akerlof [6] demonstrated that when buyers cannot observe product quality, adverse selection prevents high-quality products from obtaining commensurate prices. Spence’s signalling theory shows that if high-quality sellers can send a signal at a cost that low-quality sellers find difficult to imitate, the market can reach a separating equilibrium in which signals map onto prices [7,36]. Conversely, if sellers of both high and low qualities can acquire the same signal at similar costs, the market falls into a pooling equilibrium in which the signal no longer conveys quality differences and cannot support price differentiation [37]. The effectiveness of certification as a signal also depends on the stringency of the standard and how well the market understands it; ambiguous or lenient thresholds may cause labels to confuse rather than inform buyers [8,38].
Applied to the Taiwanese context, once regulations require buildings for public use to use a minimum share of GBMs, certification becomes a prerequisite for market entry, and every supplier wishing to participate in public works has an incentive to obtain the label. If the certification threshold does not meaningfully discriminate relative to suppliers’ existing product quality, the label will become ubiquitous, lose its separating property, and the market may settle into a pooling equilibrium. Research on green public procurement similarly indicates that the design of procurement rules shapes suppliers’ certification behavior and market responses [30]. We treat this mechanism as an interpretive hypothesis: the present data can show whether the listed prices differ by label status, but not why.
Price parity between labelled and non-labeled products can also arise without any loss of signalling value. Certification costs may be too small to require recovery through prices; recycled inputs may lower unit costs; suppliers may price product lines uniformly; procurement rules that cap or benchmark unit prices may leave little room for a markup; and buyers may be unaware of or indifferent to the label. These explanations predict the same posted-price pattern as a pooling equilibrium and are therefore treated as competing interpretations (Section 5.1).
2.4. Hypotheses
Based on this, we formulate two levels of competing hypotheses (Figure 1). The first level tests whether the label generates a premium in published list prices, and the second tests whether manufacturers manage labelled items differently along the pricing chain (channel discounts and quantity-based price tiers). The same hypothesis structure is applied to all three material categories to permit cross-category comparison.
Figure 1.
Analytical framework. A mandatory usage rate can convert the GBM label from a quality signal into a market-entry threshold. The price effect was tested at the list-price level (H1) and the pricing-chain level (H2) using matched designs and hedonic models and interpreted in terms of competing explanations (pooling equilibrium, certification costs, input costs, pricing and procurement practices, and buyer awareness). “Counted” indicates that the product counts toward the GBM usage rate under Chapter 17 of the Building Technical Regulations; ready-mixed concrete, a structural material, is not counted. Tiles provide the primary matched test; coatings and concrete are reported descriptively.
H1a (premium).
The list price of a GBM-labeled product is significantly higher than that of a non-labeled product of the same series, specification, and grade.
H1b (no premium).
The list price of a GBM-labeled product does not differ materially from that of a non-labeled product of the same series, specification, and grade; H1b is supported when the 90% confidence interval of the implicit premium lies entirely within ±5%. This margin was set prospectively and lies below the smallest observed quality-grade premium (11.0%) and the cross-item dispersion of discount ratios (SD ≈ 10 pp); because no external benchmark for a commercially material label premium was available, ±2.5% and ±10% are reported as sensitivity margins (Section 3.6).
H2a (structural difference).
Discount ratios and small-order price ratios differ systematically between labelled and non-labelled products.
H2b (structural uniformity).
Discount ratios and small-order price ratios do not differ significantly between labelled and non-labelled products, indicating uniform management of the pricing chain.
Testing H2 requires multi-tier price data. Because the concrete and coating data contain only single-tier or partial pricing information, H2 was not tested for these categories. In addition, because the concrete quotations reflect a promotional period in which the supplier set the two products at identical prices, the concrete comparison is reported descriptively and is not used as a formal test of H1b. Moreover, the coating comparison is cross-series and cannot separate certification from differences in formulation and positioning; it is therefore treated as exploratory and is not used as a formal test of H1.
3. Materials and Methods
3.1. Characteristics of Taiwan’s Green Building Material Label
Taiwan’s Green Building Material Label, administered by the ABRI since July 2004, certifies the environmental and health performance of building materials throughout their life cycle [9]. The label comprises four categories that can be grouped into two dimensions according to their objectives: human health and global sustainability (Figure 2).
Figure 2.
The four categories and two dimensions of Taiwan’s Green Building Material Label. Healthy GBMs contribute to human health, whereas ecological, recycled, and high-performance GBMs contribute to global sustainability.
- (1)
- Healthy GBMs focus on indoor environmental quality and occupant health. The emission rates of formaldehyde and total volatile organic compounds (TVOCs) were assessed against benchmark limits for interior finishing materials, such as tiles, coatings, boards, flooring, and adhesives. The evaluation criteria specify maximum emission rates of 0.05 mg/m2·h for formaldehyde and 0.19 mg/m2·h for TVOC for the product categories analyzed here [9]. Emissions from building materials are a recognized source of indoor chemical pollutants, and low-emission materials are among the main control measures for limiting indoor formaldehyde and volatile organic compound exposure [39,40]. This category constitutes the human health dimensions.
- (2)
- Ecological GBMs are assessed based on whether raw materials are natural and renewable and involve low processing, energy consumption, and toxicity, with the aim of reducing the impact of material production on natural resources and ecosystems.
- (3)
- Recycled GBMs are assessed based on their recycled content under the 3R principle (reduce, reuse, recycle), which promotes the circular use of construction and industrial waste.
- (4)
- High-performance GBMs were assessed for acoustic insulation, water permeability, and energy-saving performance, reducing operational energy demand and improving environmental comfort by enhancing the physical performance of buildings.
The ecological, recycled, and high-performance categories correspond to resource conservation, resource circulation, and energy and carbon reduction, respectively, and together, they constitute a global sustainability dimension. Two features of this framework merit emphasis. First, a single label covers two qualitatively different objectives—indoor health and global environmental protection—so that it serves as both a health safeguard and an environmental policy instrument. Second, all four categories are assessed against single-attribute performance thresholds (e.g., maximum emission rates or minimum recycled content); thus, the label is a binary pass/fail certification rather than a graded rating [9]. This feature is relevant for interpreting our results: if a binary threshold is widely met and buyers observe no meaningful variation beyond compliance, the label’s capacity to differentiate products based on performance is likely to be limited [38].
3.2. Regulatory Mandate and International Comparison
The defining difference between Taiwan’s GBM regime and those of other jurisdictions is that the share of certified materials in buildings is mandated directly by regulation. Table 1 compares material certification schemes in Taiwan and selected other jurisdictions and their relationship with building regulations. Most jurisdictions operate environmental labels or product certification schemes for building materials, such as Japan’s Eco Mark, the Korea Eco-Label, China’s Green Building Material Product Certification, Singapore Green Building Product (SGBP) certification, and Germany’s Blauer Engel. However, the uptake of these certified products is encouraged indirectly through credits in green building rating systems, such as CASBEE in Japan, G-SEED in Korea, the Assessment Standard for Green Building (GB/T 50378-2019) in China, Green Mark in Singapore, DGNB in Germany, and LEED in the United States [41,42,43,44,45,46,47,48]. Under such systems, developers decide whether to use certified materials on a cost–benefit basis; certified materials constitute optional credits, and certification retains the scope to differentiate products. Even where certain jurisdictions require buildings above a specified size to obtain green building certification or a minimum rating (for example, Singapore and Korea), material-related items remain optional credits, and no minimum share of certified materials is prescribed. Some jurisdictions additionally use green public procurement to encourage or require certified materials [30,31]. China is a notable case. Building on pilot programmes launched in 2020, a notice issued on 31 December 2024 by the Ministry of Finance, the Ministry of Housing and Urban–Rural Development and the Ministry of Industry and Information Technology (Caiku [2024] No. 36) extended the policy, from 1 January 2025, to 101 cities and municipal districts [49]. In these cities, government-procured construction projects, including hospitals, schools, office buildings, exhibition and convention centers, gymnasiums, affordable housing, and urban-renewal projects, must procure and use certified green building materials for all product categories designated as mandatory in the procurement demand standards. The optional categories selected must cover at least 40% of the building material categories involved in the project [49]. Such procurement rules resemble Taiwan’s regime in making certification a condition of market access, but they apply to government-procured projects through procurement demand standards, whereas Taiwan’s requirement applies to buildings for public use through the building permit process and is expressed as a minimum usage rate. The two regimes also differ in scope and metric: China’s requirement applies to listed project types in designated cities and is defined by product category, whereas Taiwan’s applies throughout its jurisdiction to buildings for public use and is defined as a minimum share of the finished area.
Table 1.
Green building material certification and its relationship with building regulations: Taiwan (study context) and selected comparison schemes.
Taiwan, by contrast, incorporated the GBM usage rate directly into Chapter 17 of the Building Technical Regulations. Since 2006, buildings for public use and other designated buildings have been required to achieve a minimum GBM usage rate for interior finishing materials, initially 5% and progressively raised to 60% indoors and 20% outdoors [10]. The GBM label has thus shifted from a voluntary credit option to a statutory requirement in building permit reviews. Moreover, because the usage rate is calculated on the basis of whether a product holds the label, certification directly determines whether a product counts towards compliance, with material consequences for suppliers whose principal markets are public works and large-scale developments. This direct regulatory mandate is rare internationally and constitutes the institutional premise of the present analysis.
3.3. Study Materials and Data Sources
Ceramic tiles, ready-mixed concrete, and coatings were selected for two reasons. First, they are among the product categories most commonly certified under the GBM label. Tiles and coatings are major interior surface materials that are routinely specified to meet the indoor GBM usage rate, whereas ready-mixed concrete is the structural material used in the greatest volume and a focal point of embodied carbon reduction [2,3,50], so the results relate directly to the promotion of low-carbon concrete. Tiles and coatings count toward the usage rate, whereas ready-mixed concrete, as a structural material, does not. The three categories therefore represent three distinct situations: (a) a mandate-eligible finish carrying the recycled GBM label (tiles); (b) a mandate-eligible finish carrying the healthy GBM label that incorporates recycled silica powder (coatings); and (c) a structural material carrying the recycled GBM label that is not counted toward the requirement and was quoted under temporary promotional pricing (concrete). Focusing on these widely certified categories allows the analysis to address the market segments most likely to be affected by the usage-rate requirement. Second, the three categories span indoor and outdoor applications as well as surface and non-surface materials, and differ in pricing units, specification hierarchies, and transaction modes (Table 2), allowing us to examine whether the price effect of the label varies with material attributes.
Table 2.
Basic attributes of the three material categories analyzed and characteristics of the supplier data.
Price data were obtained from price lists or quotations provided by three local GBM-certified suppliers (hereafter Firms A, B, and C). (1) Firm A, a large local tile manufacturer, provided its complete price list covering 206 SKUs (excluding accessories) in six product categories: polished porcelain, stone effect, marble effect, thick porcelain pavers, large-format porcelain slabs, and exterior wall tiles. (2) Firm B, a local ready-mixed concrete producer, provided quotations covering six supply regions (Northern, Taoyuan, Hsinchu, Central, Tainan, and Kaohsiung). (3) Firm C, a coatings manufacturer, provided its complete price list, which comprised five main-coat series, each offered in several colors at the same price, and its GBM label certificates. The edition dates, validity, value-added tax (VAT) treatment, and price tiers of the three datasets are described below and summarized in Table 2 (Panel B).
Three suppliers were identified through industry interviews conducted for the ABRI-commissioned research project. Rather than sampling suppliers at random, we purposively selected, for each material category, the firm judged most representative on the basis of three criteria: market position, breadth of its GBM-certified product range, and availability of both labelled and non-labelled products or series. Each selected firm was invited to provide its complete price schedule under a confidentiality agreement. Firm A is among the largest ceramic tile manufacturers in Taiwan by market share and holds GBM labels for multiple recycled and high-performance products; the labelled tiles analyzed here carry the recycled GBM label. Firm B is one of the three largest ready-mixed concrete producers in Taiwan and holds recycled GBM labels for several of its mixes. Firm C is a leading producer of stone-texture architectural coatings and holds healthy GBM labels for its certified series, which also contain recycled silica powder. The outcomes are posted list prices (tiles and coatings) and quotations (concrete); realized transaction prices, negotiated discounts, rebates, delivery conditions, and other contract terms were not observed.
The characteristics of the three datasets that bear on their interpretation are as follows. Firm A’s price list was effective from 1 August 2025 (updated 20 January 2026) and reported three tiers: the suggested list price (VAT included), the site (contract) price, and the unit price for small site orders at the minimum lot size of 300 ping (992 m2) (both VAT excluded). Firm B’s quotation was issued in July 2026, applied during a promotional period valid through August 2026, and reported a single tier of base unit prices and surcharges (VAT included). Firm C’s price list (valid through August 2026) reported a list, wholesale (5-gallon), and retail (1- and 5-gallon) prices (VAT included).
Scope of inference. Because the three suppliers were purposively selected as large, established firms, the results describe their price schedules rather than the Taiwan market as a whole. Each category is represented by a single supplier; therefore, supplier fixed effects and between-firm heterogeneity cannot be estimated. Large suppliers may favor price parity because certification costs are small relative to their sales, their certified product lines are broad, and their public-works channels are well established; small and medium-sized suppliers, for which certification costs weigh more heavily, may price labelled products differently.
The certification and product characteristics of the analysed products are as follows. The certification and product characteristics of the analyzed products are as follows: The labelled tiles are certified as recycled GBMs with a recycled content of 25% by mass (the recycled GBM criterion for ceramic tiles requires at least 15%), consisting of fired tile scrap, recycled process sludge, and dust-collector ash; all analyzed tiles are Class Ia (water absorption ≤ 0.5%) under CNS 9737/ISO 13006, except the exterior wall tiles, which are Class Ib (0.5% < water absorption ≤ 3%). C1 replaces at least 20% of the cement by mass with supplementary cementitious materials—ground granulated blast-furnace slag (GGBFS), fly ash, and silica fume—whereas C2 contains no supplementary cementitious materials. The supplier did not provide mix designs (water-to-binder ratios) or certified embodied carbon values for C1 and C2. Because the analysis compares posted prices rather than material performance, these omissions do not affect the price comparison, but they prevent us from relating the cement-replacement ratio to production cost or carbon intensity (Section 5.3). The certified coating series meet the healthy GBM emission limits given in Section 3.1 and contain 40% recycled silica powder by mass, although they are certified under the healthy rather than the recycled category.
To protect commercially sensitive information, product names are not disclosed, and all products are identified by codes: tile series are coded T01–T21; for ready-mixed concrete, C1 denotes low-carbon concrete with the GBM label and C2 denotes non-labelled Portland cement concrete; and coating series are coded P1–P5.
Data collection followed three principles: (1) temporal consistency—prices within a matched pair were taken from the same edition of a price list to avoid interference from price fluctuations; (2) verifiable label status—the certification status of each product was confirmed against the official label registry or certificates, and the label category, certificate number, and validity period were recorded; and (3) traceability—the source document, edition, and date of acquisition were recorded for each observation. When the price schedules were obtained, one sales representative from each firm explained, in their professional capacity, the general principles underlying the firm’s pricing and certification strategy. These explanations were not structured interviews; they were recorded as notes, were not used to define matches or outcomes, and were cited only as supplier-reported context for interpreting the quantitative results.
3.4. Matched-Pair Design
Direct matched-pair comparison is the primary analytical approach. Within the same firm and product series, labelled and non-labelled items that are identical in all recorded attributes other than label status are paired. Within-firm matching reduces confounding by brand, specification, and quality grade and strengthens comparability, so that remaining price differences can be more plausibly associated with label status; however, as with any matching design, it cannot rule out unobserved product differences [51]. The within-firm matched comparison therefore constitutes a quasi-experimental design whose credibility rests on the completeness of the recorded matching variables, and the hedonic models in Section 3.7 provide a complementary check by progressively tightening the controls. For tiles, the matching rule was applied programmatically to the attribute fields of the price list (series, size, quality grade, made-to-order status, surface form, edge treatment, anti-slip, and brushed finish) without reference to prices; because matching was rule-based rather than judgement-based, the resulting pair list is fully reproducible from these fields. Because the procedure involves no coder discretion, an inter-coder agreement statistic does not apply; to allow verification, all 28 pairs and their matching attributes are reported in Section 4.1, and the matching script and attribute data are available from the corresponding author on request. One borderline match (series T17), in which the non-labelled item belongs to a different product line without its own model number, is retained in the main analysis but flagged and excluded in sensitivity analyses. The matching variables and potential limitations for each category are summarized in Table 3.
Table 3.
Matching variables and potential limitations by material category.
3.5. Price Indicators
Four indicators were used to measure the price effect of the label, the structure of the pricing chain, and the relative influence of pricing factors (Table 4). For matched pair i, the label premium is defined as
where PG,i and PN,i are the list prices (quoted prices for concrete; per-kilogram list prices for coatings) of the labelled and unlabeled versions, respectively. The structure of the pricing chain is measured by the discount ratio and the small-order price ratio:
where Plist, Psite, and Plot denote the suggested list price (VAT included), site (contract) price (VAT excluded), and unit price of tiles for small site orders at the minimum lot size of 992 m2 (VAT excluded), respectively; dividing Plist by 1.05 removes Taiwan’s 5% VAT so that the discount ratio is computed on a net-of-VAT basis. Because Plot exceeds the site price, Sj > 1 measures a surcharge for small project orders rather than a downstream markup; it is used to test whether labelled and non-labeled items follow the same price-tier structure.
PRi = (PG,i − PN,i)/PN,i × 100%
Dj = Psite,j/(Plist,j/1.05)
Sj = Plot,j/Psite,j
Table 4.
Definitions of price indicators.
3.6. Statistical Tests
Paired price differences were tested using the paired-sample t-test or Wilcoxon signed-rank test, depending on the sample size and distribution of differences. Because many differences were exactly zero, the sign test was used as a supplement, and the proportion of zero-premium pairs was reported directly. Since the absence of a significant difference does not establish equivalence, we additionally report two one-sided test (TOST) intervals [52,53] with a ±5% margin of practical significance. Because 27 of the 28 tile pair differences were exactly zero, the paired distribution has a point mass at zero, which violates the distributional assumptions of t-based intervals. The TOST results are therefore reported only as descriptive summaries, not as a formal demonstration of equivalence, and inference for the matched pairs relies on the count of identical pairs, exact sign and randomization tests, and bias-corrected and accelerated (BCa) bootstrap intervals [54]. β ±5% margin was set in the analysis plan of the commissioned project before the price data were compiled. It lies below the implicit premium for the smallest quality-grade upgrade in the tile data (11.0%; Section 4.4) and below the cross-item dispersion of channel discount ratios (standard deviation of approximately ten percentage points). Because no external benchmark for a commercially material label premium, such as certification costs or tender price margins, was available for these product markets, the margin was treated as a stated assumption, and all equivalence conclusions were reported for ±2.5%, ±5%, and ±10% margins (Section 4.4). Because almost all paired differences are exactly zero, the number of price-discordant pairs is reported as the effective sample for paired inference, and exact sign and randomization (sign-flip) tests are reported alongside asymptotic tests. Between-group comparisons of pricing structure indicators used Welch’s independent-samples t-test, with 95% confidence intervals for the mean difference and Cohen’s d (with an approximate 95% confidence interval) as the effect size (Section 4.1). Because the coating sample comprised only three versus two series, the exact Mann–Whitney U test was used as a supplement, and the comparison was primarily descriptive. The significance level was set at α = 0.05, and all analyses were performed using Python3.13 (SciPy 1.18.1 and Statsmodels 0.15.0).
3.7. Hedonic Pricing Models
Hedonic price theory treats the price of a product as the sum of the implicit prices of its attributes of a premium larger than about 5% in the cross-sectional. Within this framework, the GBM label can be regarded as a product attribute, whose implicit price is the premium. A general cross-sectional hedonic model can be written as
where Gi is a label dummy (1 if labelled), Xik are observable attributes such as specification, grade, and region, and the implicit label premium is 100 × (eβ − 1)%. Following Kennedy [55], reported implicit premiums apply the small-sample correction 100 × [exp( − 0.5·Var()) − 1]%, where Var() is the estimated sampling variance of .
ln Pi = α + β Gi + Σk γk Xik + εi
The hedonic framework is well suited to estimating the label premium, but the direct estimation of Equation (4) on cross-sectional data is vulnerable to omitted-variable bias. Price lists typically report only a few specifications, such as size and grade, whereas attributes such as pattern, surface texture, and market positioning are difficult to quantify; if these unobserved attributes are correlated with certification (for instance, if suppliers preferentially certify their flagship series), β will be biased. Therefore, we estimate three tile models with progressively stricter controls. Before estimation, all tile prices were converted to US dollars per square meter: per-ping prices were divided by 3.306 m2, the per-piece prices of exterior wall tiles by the face area of each piece, and all prices by the exchange rate given in the note to Table 2. Because the exchange rate is a constant and the face area is absorbed by the size fixed effects, these conversions do not affect the label coefficients. Model 1 (M1) is a full cross-sectional hedonic model in which Xik includes fixed effects for product category, size, and quality grade, together with dummies for made-to-order, ridged surface, unbevelled edge, anti-slip, brushed finish, and featured items. Model 2 (M2) adds series fixed effects to M1 to absorb differences in pattern and positioning across series. Model 3 (M3) uses fixed effects for item cells comprising items with identical attributes (same series, size, grade, and identical attribute dummies):
where μc is the fixed effect of item cell c, which absorbs all attributes shared within the cell, observed or unobserved, so that β is identified solely from within-cell variation in label status. This logic parallels the repeat-sales approach in real estate research and represents the matched-pair comparison within the hedonic framework; in other words, matched-pair comparison and hedonic modelling are not alternatives but estimates of the same model under different degrees of control. Because M3 is identified only by item cells containing both labelled and non-labelled items, it is estimated on 56 observations in the 28 such cells; the 150 singleton observations, whose prices are absorbed entirely by their cell effects, are excluded, and standard errors are clustered by item cell [56]. M3 is thus the regression counterpart of the matched-pair comparison rather than an independent confirmation of it, and its interval is complemented by the exact and bootstrap procedures described in Section 3.6.
ln Pic = μc + β Gic + εic
For ready-mixed concrete, C1 and C2 were quoted at identical prices in every strength–region cell; therefore, the within-cell label difference had no variance, and any label coefficient would be mechanically zero. Therefore, a no-label model was not estimated for concrete; instead, a two-way analysis of variance (ANOVA) of the log base prices of the 36 strength–region cells (N = 36, without a label term) describes the contributions of the strength class and supply region to price variation. Heteroscedasticity-robust (HC1) standard errors were used for the M1 and M2 models. Because the coating sample contained only five series, there were insufficient degrees of freedom to estimate the attribute coefficients, and the coatings were compared descriptively. The label effect was deemed negligible when the 90% confidence interval of the implicit premium lay entirely within the ±5% equivalence margin (with ±2.5% and ±10% as sensitivity margins), consistent with the logic of the TOST procedure [53]; 95% confidence intervals are also reported.
Two further analyses used existing tile data. First, to examine whether the supplier selectively certified particular items, a logit model of certification status (GBM = 1) on quality grade, the logarithm of nominal tile area, application environment, and made-to-order status was estimated; odds ratios and average marginal effects are reported with 95% confidence intervals. Second, because Chapter 17of the Building Technical Regulations sets a higher usage rate for indoor (60%) than for outdoor (20%) applications, interactions between the label and application environment—indoor (polished porcelain, marble-effect, and large-format slabs; n = 61), mixed indoor/outdoor (stone-effect; n = 73), and outdoor (thick pavers and exterior wall tiles; n = 72) product categories—were added to M1, M2, and the pricing-tier regressions as an exploratory test of whether the label was priced differently across the two mandate tiers. Because the usage rate is calculated from where a product is installed rather than from a product attribute, this classification is only a coarse proxy for regulatory exposure.
4. Results
4.1. Ceramic Tiles
Firm A frequently offers labelled versions (distinguished by a model-number suffix) and non-labelled versions within the same series, providing the closest available approximation to a quasi-experimental comparison. The analytical sample derived from the complete price list comprised 206 SKUs, of which 75 were labelled and distributed across 64 product series. The distribution of the product categories is presented in Table 5.
Table 5.
Distribution of the tile sample by product category.
Applying the rule ‘same series, size, and quality grade, with identical made-to-order status, surface form (flat or ridged), edge treatment, anti-slip, and brushed attributes’ systematically across all items identified 28 pairs in which both labelled and non-labelled versions exist (Table 6). In 27 pairs (96.4%), the list prices (including VAT) are identical, as are the site and small-order prices. Only one pair (series T17, 90 × 180 cm, Standard A) differs, with the labelled version 1.61% cheaper; the non-labelled item in this pair belongs to a different product line without its own model number, so the match is comparatively weak. Quality grades follow the supplier’s designations: Standard B (lowest), Standard A, Premium B, and Premium A (highest).
Table 6.
Matched-pair comparison of list prices for labelled and unlabeled tiles of the same series, specification, and grade (USD/m2, VAT included).
The descriptive evidence is the primary result. Of the 28 pairs, 27 (96.4%) have identical list prices (pairwise difference exactly 0.00%), and the remaining pair differs by −1.61%; the mean premium is −0.06% (SD = 0.30%; median = 0.00%). The effective number of informative, price-discordant pairs is therefore one, which limits inference beyond this descriptive pattern: the exact sign test and the exact randomization (sign-flip) test both yield p = 1.00. Excluding the weakly matched T17 pair, all 27 remaining pairs have identical list, site, and small-order prices, so the premium is exactly zero. Because the paired distribution has a 96.4% point mass at zero, t-based intervals are not appropriate; the BCa bootstrap interval for the mean premium is [−0.23%, 0.00%] at 90% and [−0.29%, 0.00%] at 95%. These intervals are narrow because only one pair differs, not because equivalence has been demonstrated with high precision; the parametric TOST interval ([−0.16%, 0.04%]) is reported only as a descriptive summary. The primary result is the observed pattern: 27 of 28 pairs have identical prices, and the 28th differs by −1.61%. None of these intervals adds inferential power beyond the descriptive count, and we do not interpret them as proof of equivalence. Figure 3 plots the matched prices on logarithmic scales; all observations lie on or within ±5% of the zero-premium line. These results are consistent with H1b for the observed price schedule.
Figure 3.
List prices of labelled versus non-labeled versions in 28 matched tile pairs (logarithmic scales). The dashed line denotes zero premium (y = x), and the gray band denotes the ±5% reference margin; triangles denote exterior wall tiles priced per piece, and the diamond the single pair with a price difference.
To examine the supplier’s pricing logic further, we calculated the discount ratio (site price ÷ net-of-VAT list price) and the small-order price ratio (992-m2 minimum-lot unit price ÷ site price) for all 206 SKUs (Table 7 and Figure 4). Because the list price includes Taiwan’s 5% VAT, whereas the site price does not, the list price was divided by 1.05 before the discount ratio was computed. In the full sample, the mean discount ratio of labelled items (60.80%) is lower than that of non-labelled items (66.30%; difference −5.51 pp, 95% CI [−8.75, −2.26]; d = −0.48), and the small-order price ratio is also slightly lower (1.2095 vs. 1.2310; d = −0.41); both differences are significant (p = 0.001). However, these differences stem from product composition: exterior wall tiles, which are priced per piece, have markedly higher discount ratios (approximately 81% on average), and only four of them are labelled. Excluding wall tiles, neither the discount ratio (59.58% vs. 61.26%, p = 0.27; d = −0.18, 95% CI [−0.49, 0.13]) nor the small-order price ratio (1.2038 vs. 1.2039, p = 0.86; d = −0.03) differs significantly. After controlling for product category, size, quality grade, and made-to-order status in a regression, the label has no significant effect on either the discount ratio (β = 0.006, p = 0.10) or the small-order price ratio (β = 0.005, p = 0.10), and 27 of the 28 matched pairs have identical site and small-order prices. Adding label × application–environment interactions (Section 3.7) shows no difference between indoor and outdoor product categories (discount ratio: p = 0.70; small-order price ratio: p = 0.60). Overall, the results support H2b for this price schedule, indicating that Firm A manages labelled and non-labelled items through a uniform pricing chain, and that the full-sample differences reflect product composition rather than the label itself.
Table 7.
Pricing structure of labelled and non-labelled tiles.
Figure 4.
Pricing structure indicators of labelled and non-labelled tiles: (a) discount ratio (site price ÷ net-of-VAT list price); (b) small-order price ratio. The markers denote the mean, and the error bars denote ±1 standard deviation. The left and right groups show the full sample and the sample excluding the exterior wall tiles, respectively.
Relative to the label, the quality grade is the core basis of Firm A’s price differentiation. Table 8 lists the list prices of different quality grades within the same series. The ratio of the highest- to the lowest-grade price ranges from 1.08 to 1.71, whereas the median price multiplier of the label across matched pairs is 1.00 (Figure 5). In other words, the supplier is willing to differentiate prices by up to 70% according to grade but charges nothing for the labels. The hedonic models in Section 4.4 further quantify the implicit prices of these characteristics.
Table 8.
Examples of list-price multipliers across quality grades within the same series (USD/m2).
Figure 5.
Price multipliers across tile-quality grades compared with the price multiplier of the recycled GBM label. Grey bars indicate the ratio of the highest- to the lowest-grade list price within each series (Table 8); the green dot indicates the median price multiplier of the GBM label across the 28 matched pairs (labelled ÷ non-labelled). The dashed line (1.00×) indicates no price difference.
4.2. Ready-Mixed Concrete
Firm B’s quotations compare low-carbon concrete holding the recycled GBM label (C1) with non-labelled Portland cement concrete (C2). The quotations cover six supply regions, each listing base unit prices for six strength classes from 2000 P to 7000 P (the supplier’s designation of nominal 28-day compressive strength in psi; for example, 3000 P ≈ 210 kgf/cm2 ≈ 20.7 MPa), along with surcharges for four performance options: slump of 20 cm or more, fine aggregate, high-fluidity concrete (HFC), and self-compacting concrete (SCC). According to the supplier, C1 was sold at the same price as C2 during a promotional period; therefore, the data reflect promotional prices rather than standard list prices. Thus, the concrete result is mechanically determined by the supplier’s promotional parity and is treated as a case study of promotional pricing, not as evidence of stable market parity. Moreover, structural concrete is not counted toward the GBM usage rate, which applies to interior finishing and exterior surface materials. Therefore, the concrete case does not test the mandate mechanism directly but illustrates how a certified low-carbon product is priced relative to its conventional counterpart. Matching the supply region and strength class yields 36 main product pairs, and the four surcharges provide 24 additional pairs, which are reported descriptively. Because the quotations contain only a single price tier and the C1–C2 parity was set by the supplier’s promotional policy, H2 is not examined, and H1 is examined descriptively only.
The premium was 0.00% in all 36 main-product pairs, and all 24 surcharge pairs were likewise identical (Table 9 and Figure 6). Because every paired difference was zero and therefore had no variance, the results are reported descriptively without formal hypothesis testing. In other words, during the promotional period C1 carried no quoted premium; because this parity was set by the supplier’s promotional policy, it is not used as a formal test of H1b. Moreover, identical prices do not imply identical costs. Low-carbon ready-mixed concrete typically lowers its carbon intensity by partially replacing cement with industrial by-products, which can be cheaper than clinker where locally available [27,28]. C1 uses a blend of GGBFS, fly ash, and silica fume; slag and fly ash are usually cheaper than clinker, whereas silica fume is usually more costly; therefore, the net effect on binder cost depends on the blend proportions; if C1 is cheaper to produce, the supplier earns a larger margin on it at the same price. Without cost data, these margin implications cannot be quantified.
Table 9.
Prices of C1 and C2 by supply region (USD/m3).
Figure 6.
Ready-mixed concrete prices by strength class and supply region. C1 and C2 were priced identically during the promotional period; therefore, their curves overlapped.
In contrast to the label, strength, region, and workability, all generate substantial price differentials. Within a supply region, each step from 2000 P to 6000 P adds USD 3.2–9.6/m3, and the cumulative increase from 2000 P to 6000 P is approximately 19–29%. However, the step from 6000 P to 7000 P jumps to USD 31.9–47.8/m3, a discontinuity consistent with a distinct high-strength product tier; higher strength classes generally require higher binder contents [50], but confirming the compositional or production basis of this step would require mix-design data that are not provided in the quotations. The 7000 P/2000 P price multiplier ranged from 1.47–1.76. Within a strength class, the Northern region is the most expensive, and Hsinchu is the least expensive in every class. The regional multiplier ranges from 1.16 to 1.30, and the largest regional difference (USD 23.6–26.8/m3) exceeds the surcharge for moving from 2000 P to 5000 P within a region (USD 12.8–15.9/m3), indicating that location influences prices at least as much as strength specifications. The quotations do not identify the underlying causes, which may include haul distance, aggregate sources, and regional supply–demand conditions, among others. Among the four performance options, SCC incurs the highest surcharge (USD 12.8–14.4/m3, or 10.7–15.0% of the 3000 P base price), applied equally to C1 and C2. The price multipliers for the pricing factors are listed in Table 10.
Table 10.
Price multipliers of pricing factors for ready-mixed concrete.
4.3. Coatings
Coating labels are issued per series, and all color variants of a series are covered by the same certificate; therefore, matched pairs of labelled and non-labeled versions within a series cannot be formed. The supplier’s sales representative explained three features of coating pricing: (1) prices were determined mainly by the type and proportion of resins, aggregates, pigments, and additives; (2) products within a series differ mainly in color and share the same principal composition; and (3) the category for which certification was sought reflected the product being promoted at the time of application, and holding the label had become an entry requirement for building projects in which their products were specified.
Accordingly, a within-category cross-series comparison was adopted, restricted to main coat finishes with the same function and application. Cross-checking Firm C’s price list against its certificates shows that series P1, P2, and P3 are certified, whereas P4 and P5 are not, forming a natural comparison of three and two series (Table 11). Firm C’s price list comprises only these five series, each offered in several colors at the same price. Table 11 presents the complete price list. To remove the effects of package size and spreading rate, list prices were converted into a price per kilogram (list price ÷ package weight) and a price per square meter (list price ÷ mid-point of coverage), together with the range implied by the minimum and maximum stated coverage (Table 11). The pricing-chain structure was measured using the wholesale discount ratio (wholesale price ÷ list price) and the retail discount ratio (5-gallon retail price ÷ list price). Because the labelled and non-labelled series differ in formulation, positioning, and likely performance, this comparison cannot identify a label effect and is reported as exploratory and descriptive.
Table 11.
Unit prices and pricing structure of main-coat finishes.
Figure 7.
Unit prices of labelled and non-labelled main-coat finishes: (a) list price per kilogram; (b) material cost per square meter. The labelled series average USD 8.93/kg and USD 10.02/m2, the and non-labelled series average USD 14.48/kg and USD 14.29/m2.
Regarding the pricing chain, labelled series have higher average wholesale and retail ratios (i.e., smaller discounts); however, this difference is driven by series P3 (wholesale ratio 88.1%). Excluding P3, the wholesale ratios of P1 and P2 are approximately 73%, similar to that of P5 (70.6%). Series P4 has the largest discount (63.2%), which more plausibly reflects the practice of leaving wider channel margins on high-priced products than any label effect does. Because cross-series comparison cannot rule out confounding by formulation, the pricing-chain results for coatings are reported descriptively.
4.4. Hedonic Estimates for Tiles
Table 12 reports the hedonic estimates for tiles, with prices expressed in USD/m2 and implicit premiums corrected following Kennedy [55]. The full cross-sectional model M1 explains 98.7% of the variation in log prices; the label coefficient is −0.0093 (robust SE = 0.0192, p = 0.63), corresponding to an implicit premium of −0.95% with a 90% confidence interval of [−4.02%, 2.26%] (95% CI: [−4.60%, 2.88%]), within the ±5% margin. In the same model, the implicit prices of quality grades are clearly identified: relative to Standard B, the implicit premiums for Standard A, Premium B, and Premium A are 11.0%, 25.8%, and 60.3%, respectively (Figure 8). In this price schedule, the quality grade is priced explicitly, whereas the label is not.
Figure 8.
Implicit premiums from the tile hedonic models (Kennedy-corrected; prices in USD/m2). Green markers denote the recycled GBM label coefficients in M1 (cross-sectional), M2 (series fixed effects), and M3 (item-cell fixed effects, 56 observations); thick and thin bars show 90% and 95% confidence intervals. Grey markers denote the implicit premiums of quality grades relative to Standard B in M1. The grey band indicates the ±5% reference margin, and the dashed line zero premium. M2 is annotated because its 90% CI exceeds +5%; the M3 interval is narrower than the marker and is descriptive (Table 12, note d). Grade premiums are shown as point estimates.
In M2, which adds series fixed effects, the label coefficient is 0.0273 (robust SE = 0.0159, p = 0.09), an implicit premium of 2.75% with a 90% confidence interval of [0.11%, 5.49%] (95% CI: [−0.39%, 6.02%]). Because the upper bound of the 90% interval exceeds +5%, M2 does not support equivalence at the ±5% margin, and its point estimate is positive. The logit model of certification status explains this. Holding grade and application environment constant, the supplier is more likely to certify larger-format items (odds ratio per unit increase in log nominal area 1.99, 95% CI [1.53, 2.59]; average marginal effect 0.13 [0.09, 0.17]) and items in outdoor (OR 6.55 [2.62, 16.40]) and mixed-use categories (OR 4.11 [1.81, 9.33]), and less likely to certify made-to-order items (OR 0.08 [0.02, 0.32]), whereas quality grade is not associated with certification (Standard A OR 0.74 [0.35, 1.55]; Premium B 0.74 [0.29, 1.93]; Premium A 0.48 [0.14, 1.65]; McFadden pseudo-R2 = 0.17). Therefore, within series, labelled items are disproportionately larger formats, for which the assumption in M2 that size differentials are common across series extrapolates poorly; leave-one-series-out estimates range from 1.5% to 3.3%. The positive M2 estimate is more plausibly attributed to selective certification of larger formats than to a label premium, but a small premium for such items cannot be ruled out.
When the estimation is restricted to the 28 item cells (56 observations) that contain both labelled and non-labelled items, with standard errors clustered by item cell (M3), the label coefficient is −0.0006 (p = 0.48), an implicit premium of −0.06% (cluster-robust 90% CI [−0.19%, 0.08%]; BCa bootstrap 90% CI [−0.23%, 0.00%]). Because only one of the 28 cells (T17) contains a price difference, these intervals summarize a single discordant pair; excluding T17, the label coefficient is zero. The conclusions of all models remain unchanged when the site price is used as the dependent variable (M1 −0.38%, M2 2.89%) or when the 90 × 180 cm slabs are excluded from the analysis. Excluding the T17 items changes M1 (−0.95%; 90% CI [−4.03%, 2.28%]) and M2 (2.82%; [0.12%, 5.63%]) negligibly, and excluding the 11 observations with a Cook’s distance above 4/n yields an M1 premium of −0.89% ([−3.54%, 1.87%]).
Adding interactions between the label and application environment provides no evidence that the label is priced differently across the two mandate tiers. In M1, the label × outdoor interaction is −0.3% (95% CI [−11.1%, 11.8%]) and the label × mixed-use interaction 5.5% ([−2.5%, 14.3%]); the two are jointly insignificant (χ2(2) = 2.16, p = 0.34). In M2, the corresponding interactions are 0.3% ([−8.2%, 9.6%]) and 0.9% ([−6.3%, 8.7%]) (joint p = 0.97). The intervals are wide, so these results do not exclude moderate differences between mandate tiers, and because the application environment is only a coarse proxy for regulatory exposure, they do not identify a mandate effect.
For ready-mixed concrete, no label coefficient is estimated because C1 and C2 prices are identical in every cell (Section 3.7). A two-way ANOVA of the 36 log base prices shows that strength class and supply region together explain 98.7% of the variation—strength class 83.1% and supply region 15.7%, with a residual of 1.3%. In the additive two-way model underlying the ANOVA (without a label term), the premium of 7000 P over 2000 P is 61.8%, and that of the Northern over the Central region is 18.8%.
Table 12 also reports the equivalence conclusions under ±2.5%, ±5%, and ±10% margins, based on 90% confidence intervals. M1 lies within ±5% and ±10%, but not ±2.5%. M2 lies within ±10% only: its 90% interval [0.11%, 5.49%] excludes zero and exceeds +5%, so M2 does not support equivalence at the main margin. M3 lies within all three margins, but because its interval reflects a single discordant pair, this is a descriptive rather than an inferential result. Hence, the tile price schedule supports the absence of a premium larger than about 5% in the cross-sectional specification, whereas the series fixed-effects specification leaves open a small positive premium for selectively certified items.
Table 12.
Hedonic estimates for tiles (dependent variable: log of the list price in USD/m2).
4.5. Cross-Category Synthesis
Table 13 summarizes the evidence for the three categories, and Figure 9 compares the price multipliers of the pricing factors in the two regions. The evidence differs in strength: tiles provide matched within-series evidence, concrete reflects a promotional quotation period, and coatings provide only an exploratory cross-series comparison of the evidence. Across these price schedules, the price multiplier of the label is 1.00 in the tile-matched pairs (27 of 28 pairs) and under the supplier’s promotional pricing in the concrete quotations (descriptive only) and below 1 for coatings (exploratory), whereas specification and geographic factors—quality grade, design strength, supply region, and workability—are associated with multipliers of 1.08 to 1.76. In these suppliers’ schedules, prices are differentiated by product specifications, workability, and geography rather than by the GBM label. Because the three categories also represent different label categories and regulatory situations (Section 3.3), the results are not pooled into a single conclusion regarding the GBM label.
Table 13.
Summary of the evidence for the three material categories by evidentiary strength.
Figure 9.
Price multipliers of pricing factors across the three material categories. Grey bars show the range of multipliers across specification, grade, region, and workability factors (highest ÷ lowest price within the stated comparison). The filled green circle denotes the label multiplier based on matched within-series evidence (tiles; median of 28 pairs); open green diamonds denote label multipliers that are descriptive only (concrete, promotional quotation) or exploratory (coatings, cross-series comparison in USD/kg, confounded by formulation). The dashed line indicates 1.00× (no price difference). Sources: Table 6, Table 8, Table 10 and Table 11.
5. Discussion
5.1. Interpreting Listed-Price Parity: Competing Explanations
The absence of a substantial listed-price premium in these three price schedules admits several explanations, and the present design, which contains at most proxy-level variation in regulatory exposure, cannot distinguish among them. We therefore set them out in parallel rather than prioritizing any one. (i) Pooling equilibrium: once the Building Technical Regulations require a minimum usage rate, certification becomes a prerequisite for supplying buildings subject to the requirement, suppliers of differing environmental quality all have an incentive to obtain the label, and the label may lose its separating property [7,37]. (ii) Low certification costs: if certification costs are small relative to product prices, or are absorbed rather than passed through, there is little to recover through a premium [8]. (iii) Input-cost savings: recycled raw materials and supplementary cementitious materials can reduce unit costs [27,28,29]; the labelled tiles contain 25% recycled material and C1 replaces at least 20% of the cement with GGBFS, fly ash, and silica fume (Section 3.3); equal prices would then imply a larger margin on certified items rather than a zero-cost premium. (iv) Uniform pricing and procurement constraints: suppliers may price product lines uniformly for reasons unrelated to the label, procurement that emphasizes minimum compliance and price competition, or procurement rules that cap or benchmark unit prices, may leave little scope for a label-specific markup [57]. (v) Buyer indifference: buyers may be unaware of, or indifferent to, the label. In addition, posted prices may not capture label-related differences in negotiated discounts, rebates, tender eligibility, or bid success. The exploratory interaction analysis (Section 4.4) found no difference in the label’s price effect between indoor and outdoor product categories, but its wide intervals and coarse proxy for regulatory exposure mean that it cannot discriminate among these explanations. The coating supplier’s sales representative described the label as an entry requirement; this anecdotal account does not discriminate among these explanations. Distinguishing them would require cost data (for ii and iii), transaction or tender data (for iv), buyer surveys (for v), and genuine variation in regulatory exposure, for example, comparisons between projects subject and not subject to the usage-rate requirement, before and after changes in the mandated rates, or with comparable voluntary regimes (for i).
These results stand in clear contrast to the building-level literature, which generally finds rental and sale-price premiums for green certification [11,12,13,15], although Chegut et al. also show that the premium declines as the supply of certified buildings increases [14]. Under explanation (i), the present findings would represent a limiting case of this scarcity mechanism, in which regulation makes a label ubiquitous and its price effect approaches zero; under the other explanations, the contrast reflects differences in cost structures, pricing practices, or buyer behavior rather than in signalling value. Explanation (i) also accords with the theoretical prediction that certification standards that fail to discriminate clearly between quality levels weaken the informational value of labels [38].
5.2. Policy Hypotheses for Net-Zero Materials
These findings have dual implications for net-zero material policies. On the positive side, in the observed list-price and quotation data, no substantial price premium corresponding to the label was found in the listed prices and promotional quotations of the three suppliers observed, suggesting that, for these suppliers, the usage-rate requirement does not raise posted material prices through label-specific markups. However, procurement, installation, and transaction costs were not observed. For this supplier’s promotional quotations, labelled low-carbon concrete likewise carried no list-price premium over Portland cement concrete, indicating that this supplier was able to offer a lower-carbon mix at price parity during the promotion; whether parity persists under standard pricing and at scale remains untested [2,3]. However, if the label does not differentiate between levels of environmental performance, it is likely to provide little market incentive for suppliers to invest in lower-carbon formulations or processes. For net-zero objectives, the question is no longer whether green materials are used, but how low-carbon those materials are.
The results also bear on circular economy policy. In all three categories, the labelled products contain recycled materials: the tiles (25% recycled content) and the low-carbon concrete (at least 20% cement replacement with industrial by-products) carry the recycled GBM label, and the certified coatings, although certified under the healthy rather than the recycled category, contain 40% recycled silica powder. That these products were listed or quoted at parity with their non-labelled counterparts indicates that, at least in the posted prices of these suppliers, certification did not make recycled-content materials more expensive in posted prices (for concrete, under promotional pricing). Price parity also has a distributional reading. Where recycled inputs lower unit costs—for example, through the 25% recycled content of the labelled tiles or, depending on the blend proportions, the cement replacement in C1 (Section 2.2 and Section 4.2)—parity implies that these savings accrue to suppliers as a larger margin rather than being passed on to buyers as lower prices. Suppliers would then have a private incentive to certify and increase recycled content, even without a price premium, but public buyers would not share in the cost savings. Whether this is the case cannot be determined without cost data (Section 5.3). For these suppliers, the market-entry barrier for recycled materials therefore does not appear to lie in posted prices, although posted-price parity does not imply parity in transaction prices or total procurement costs. Policy efforts to expand their use may be better directed at non-price barriers commonly reported for green and recycled construction materials, such as perceived performance risk, conservative specification practices, supply reliability, and the cost and complexity of testing and certification for suppliers [17,18,19]. Because procurement, negotiation, and installation costs were not observed, this inference is limited to posted prices.
In terms of the SDGs, the findings speak directly to Target 12.7 [5]. Taiwan’s usage-rate requirement is, in effect, a sustainable public procurement rule embedded in building regulations. In the observed price schedules, the requirement could be met without a label-specific price premium, suggesting that this form of sustainable procurement need not raise the posted material prices faced by projects subject to the requirement. Because certification, administration, and other compliance costs were not measured, this finding concerns material prices only and is not evidence of the overall cost or fiscal burden of the policy. Within this scope, the absence of a material-price premium is consistent with the uptake of recycled-content materials under Target 12.5 without an added material-price barrier. However, a procurement rule that rewards the presence of a label rather than the level of environmental performance advances Target 12.7 more in form than in substance: it secures adoption but offers little incentive to reduce embodied carbon further, which limits its contribution to Target 9.4 and SDG 13. Linking the label and procurement criteria to measured performance, as proposed below, would allow the same instrument to contribute to these goals more fully.
These findings motivate three policy hypotheses that the present price data do not evaluate. First, if the observed parity reflects a pooling equilibrium, developing the binary GBM label into a graded scheme based on carbon footprints or EPDs may restore its discriminating power and the conditions for a separating equilibrium [26,50]; if it instead reflects low certification costs or input-cost savings, grading would serve mainly to differentiate environmental performance rather than prices. Assessing this would require price and certification data before and after a grading reform. Second, introducing embodied-carbon performance criteria into public works procurement, for example, strength-class-specific carbon limits or scoring bands for concrete, may allow low-carbon performance to translate into a competitive advantage in tendering [30,31,57]. EPD-based procurement frameworks that set global-warming-potential limits for concrete, such as the requirements adopted by the US General Services Administration and the framework proposed for Canadian government projects, provide templates [58,59]; their effects in Taiwan could be evaluated using bidder-level responses and carbon-intensity data linked to procurement outcomes. Third, the method of calculating the GBM usage rate could be reviewed to incorporate non-surface materials, such as concrete, which account for a large share of embodied carbon [1]; evaluating this option would require data on the carbon intensity of the materials specified under the revised rule.
5.3. Limitations and Future Research
This study has several limitations. First, each category is represented by a single, purposively selected supplier; therefore, the findings describe the participating firms’ price schedules and cannot be extrapolated to the Taiwan market as a whole; supplier fixed effects and between-firm heterogeneity could not be assessed. In addition, although the matched design controls for recorded attributes, it cannot exclude unobserved product differences. Second, the analysis relies mainly on list prices or quotations and does not observe actual transaction prices after project-level negotiation; any effect of the label at the negotiation stage would not be reflected in list prices. Third, the concrete data reflect promotional pricing, and whether price parity persists under standard pricing remains to be verified. Fourth, the cross-series comparison for coatings cannot fully exclude confounding by formulation. Fifth, the study does not cover private-sector markets without usage-rate requirements; whether the label carries a greater signal value in such markets would provide a useful counterfactual for distinguishing among the explanations in Section 5.1. Sixth, because the tile data derive from a single supplier’s price list, the hedonic estimates capture within-firm rather than market-wide implicit prices. Seventh, explanations provided by a single sales representative per firm, such as the role of composition in coating prices and the label as an entry requirement, reflect that representative’s perspective and could not be verified independently. Eighth, the design contains at most proxy-level variation in regulatory exposure (indoor versus outdoor product categories) and therefore cannot identify whether the mandate causes the observed price parity. Ninth, no cost or margin data were available, so equal prices cannot be interpreted as equal costs or margins, and the concrete supplier did not provide mix designs or embodied-carbon values, so the cement-replacement ratio cannot be related to production cost or carbon intensity; and because the analyzed products carry recycled or healthy labels, the results cannot be generalized to the ecological and high-performance label categories. Tenth, certification fees, the administrative costs of usage-rate calculation and permit review, and other compliance costs borne by suppliers, designers, and building authorities were not measured, so the findings bear on material prices only and not on the overall cost of the requirement. Future research could extend the analysis to metal roofing and façade systems and calcium silicate boards, collect multi-supplier, full-range price data and invoice-level or project-quotation data (including order quantity, buyer type, delivery distance, and negotiated discounts) to estimate cross-sectional or panel hedonic models of the implicit label price and its heterogeneity across suppliers and markets, and quantify certification and administrative compliance costs to assess the overall cost of the requirement, and compare Taiwan with jurisdictions operating voluntary regimes to strengthen causal inference.
6. Conclusions
Focusing on Taiwan’s Green Building Material Label, this multi-material case study combined within-supplier matched-pair comparisons with hedonic pricing models to examine posted price differentials associated with the label in the price schedules of three purposively selected suppliers. The evidence differs by category. (1) For recycled-label ceramic tiles that count toward the usage-rate requirement (206 SKUs), 27 of 28 matched pairs have identical list prices, and the only discordant pair is weakly matched; the cross-sectional hedonic estimate of the implicit label premium is −0.95% (90% CI: −4.02% to 2.26%), whereas the series fixed-effects estimate (+2.75%; 90% CI: 0.11% to 5.49%) does not support equivalence at ±5% and appears to reflect selective certification of larger formats; the price-tier structure does not differ once product composition is controlled for. (2) For recycled-label low-carbon concrete, which is not counted toward the usage rate, the promotional quotation priced it identically to Portland cement concrete in all region–strength cells; this parity was set by the supplier and is reported descriptively, not as a test of H1b. (3) For healthy-label coatings, which contain recycled silica powder and count toward the usage rate, an exploratory cross-series comparison provides no evidence that certified series are priced higher. (4) Quality grade, design strength, supply region, and workability are associated with price multipliers of 1.08–1.76, far exceeding any label differential. Overall, no substantial price premium corresponding to the label is found in the listed prices and promotional quotations of the three suppliers observed in this paper. This posted-price parity is not equivalent to transaction-price parity or total procurement-cost parity, and it cannot be extrapolated to the Taiwan market as a whole or to other label categories. The design cannot distinguish among competing explanations: a pooling equilibrium in which the mandated label functions as a market-entry threshold, low certification costs, input-cost savings from recycled content, uniform pricing, and procurement constraints, and buyer indifference. Carbon-graded labelling and embodied-carbon criteria in public procurement are proposed as policy hypotheses to be evaluated with transaction-level, multi-supplier, and before-and-after data. In terms of the SDGs, the usage-rate requirement did not raise these suppliers’ posted material prices through a label premium (Target 12.7), although certification, administration, and other compliance costs were not measured; its contribution to climate goals depends on linking the label to measured carbon performance.
Author Contributions
Methodology, Y.-L.T. and S.-K.L.; investigation, Y.-L.T.; data curation, Y.-L.T.; writing—original draft preparation, T.-c.S.; writing—review and editing, S.-K.L.; supervision, S.-K.L.; project administration, S.-K.L.; funding acquisition, T.-c.S. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Architecture and Building Research Institute, Ministry of Interior, Taiwan (grant number 11515B4001).
Institutional Review Board Statement
This study did not involve minors, prisoners, Indigenous peoples, pregnant women, persons with disabilities or mental illness, or other individuals who may be subject to undue coercion or unable to make decisions voluntarily. Accordingly, this study met the criteria for exemption from ethics review under Article 5, Paragraph 1 of the Human Subjects Research Act applicable in Taiwan, as specified in the announcement on the scope of human subjects research exempt from ethics review (Announcement No. 1010265075, issued by the former Department of Health, now the Ministry of Health and Welfare, on 5 July 2012).
Informed Consent Statement
Not applicable.
Data Availability Statement
The price data used in this study were provided by cooperating suppliers under commercial confidentiality agreements and cannot be made publicly available due to restrictions. Aggregated data are available from the corresponding author upon reasonable request and with the suppliers’ consent.
Acknowledgments
The authors wish to express their sincere appreciation for the project funding provided by the Architecture and Building Research Institute, Ministry of Interior, Taiwan (project number: 11515B4001). The authors also thank the suppliers for providing price lists and explanations of their pricing practices so that the project could be carried out smoothly.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Röck, M.; Saade, M.R.M.; Balouktsi, M.; Rasmussen, F.N.; Birgisdottir, H.; Frischknecht, R.; Habert, G.; Lützkendorf, T.; Passer, A. Embodied GHG Emissions of Buildings—The Hidden Challenge for Effective Climate Change Mitigation. Appl. Energy 2020, 258, 114107. [Google Scholar] [CrossRef] [Scilit]
- Habert, G.; Miller, S.A.; John, V.M.; Provis, J.L.; Favier, A.; Horvath, A.; Scrivener, K.L. Environmental Impacts and Decarbonization Strategies in the Cement and Concrete Industries. Nat. Rev. Earth Environ. 2020, 1, 559–573. [Google Scholar] [CrossRef] [Scilit]
- Miller, S.A.; Horvath, A.; Monteiro, P.J.M. Readily Implementable Techniques Can Cut Annual CO2 Emissions from the Production of Concrete by over 20%. Environ. Res. Lett. 2016, 11, 074029. [Google Scholar] [CrossRef] [Scilit]
- National Development Council. Taiwan’s Pathway to Net-Zero Emissions in 2050; National Development Council: Taipei, Taiwan, 2022. Available online: https://www.ndc.gov.tw/en/ (accessed on 1 October 2026).
- United Nations General Assembly. Transforming Our World: The 2030 Agenda for Sustainable Development; Resolution A/RES/70/1; United Nations: New York, NY, USA, 2015; Available online: https://sdgs.un.org/2030agenda (accessed on 9 October 2026).
- Akerlof, G.A. The Market for “Lemons”: Quality Uncertainty and the Market Mechanism. Q. J. Econ. 1970, 84, 488–500. [Google Scholar] [CrossRef] [Scilit]
- Spence, M. Job Market Signaling. Q. J. Econ. 1973, 87, 355–374. [Google Scholar] [CrossRef] [Scilit]
- Dranove, D.; Jin, G.Z. Quality Disclosure and Certification: Theory and Practice. J. Econ. Lit. 2010, 48, 935–963. [Google Scholar] [CrossRef] [Scilit]
- Architecture and Building Research Institute (ABRI), Ministry of the Interior. Green Building Material Labeling System. Available online: https://www.abri.gov.tw/ (accessed on 1 October 2026).
- Ministry of the Interior. Building Technical Regulations, Chapter 17 Green Building Standards (Article 321); Laws & Regulations Database. Available online: https://law.moj.gov.tw/ (accessed on 1 October 2026).
- Eichholtz, P.; Kok, N.; Quigley, J.M. Doing Well by Doing Good? Green Office Buildings. Am. Econ. Rev. 2010, 100, 2492–2509. [Google Scholar] [CrossRef] [Scilit]
- Fuerst, F.; McAllister, P. Green Noise or Green Value? Measuring the Effects of Environmental Certification on Office Values. Real Estate Econ. 2011, 39, 45–69. [Google Scholar] [CrossRef] [Scilit]
- Deng, Y.; Li, Z.; Quigley, J.M. Economic Returns to Energy-Efficient Investments in the Housing Market: Evidence from Singapore. Reg. Sci. Urban Econ. 2012, 42, 506–515. [Google Scholar] [CrossRef] [Scilit]
- Chegut, A.; Eichholtz, P.; Kok, N. Supply, Demand and the Value of Green Buildings. Urban Stud. 2014, 51, 22–43. [Google Scholar] [CrossRef] [Scilit]
- Brounen, D.; Kok, N. On the Economics of Energy Labels in the Housing Market. J. Environ. Econ. Manag. 2011, 62, 166–179. [Google Scholar] [CrossRef] [Scilit]
- Kahn, M.E.; Kok, N. The Capitalization of Green Labels in the California Housing Market. Reg. Sci. Urban Econ. 2014, 47, 25–34. [Google Scholar] [CrossRef] [Scilit]
- Tatari, O.; Kucukvar, M. Cost Premium Prediction of Certified Green Buildings: A Neural Network Approach. Build. Environ. 2011, 46, 1081–1086. [Google Scholar] [CrossRef] [Scilit]
- Dwaikat, L.N.; Ali, K.N. Green Buildings Cost Premium: A Review of Empirical Evidence. Energy Build. 2016, 110, 396–403. [Google Scholar] [CrossRef] [Scilit]
- Darko, A.; Chan, A.P.C. Review of Barriers to Green Building Adoption. Sustain. Dev. 2017, 25, 167–179. [Google Scholar] [CrossRef] [Scilit]
- Rosen, S. Hedonic Prices and Implicit Markets: Product Differentiation in Pure Competition. J. Political Econ. 1974, 82, 34–55. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kok, N.; Jennen, M. The Impact of Energy Labels and Accessibility on Office Rents. Energy Policy 2012, 46, 489–497. [Google Scholar] [CrossRef] [Scilit]
- Fuerst, F.; McAllister, P.; Nanda, A.; Wyatt, P. Does Energy Efficiency Matter to Home-Buyers? An Investigation of EPC Ratings and Transaction Prices in England. Energy Econ. 2015, 48, 145–156. [Google Scholar] [CrossRef] [Scilit]
- Ward, D.O.; Clark, C.D.; Jensen, K.L.; Yen, S.T.; Russell, C.S. Factors Influencing Willingness-to-Pay for the ENERGY STAR Label. Energy Policy 2011, 39, 1450–1458. [Google Scholar] [CrossRef] [Scilit]
- Teisl, M.F.; Roe, B.; Hicks, R.L. Can Eco-Labels Tune a Market? Evidence from Dolphin-Safe Labeling. J. Environ. Econ. Manag. 2002, 43, 339–359. [Google Scholar] [CrossRef] [Scilit]
- Kollert, W.; Lagan, P. Do Certified Tropical Logs Fetch a Market Premium? A Comparative Price Analysis from Sabah, Malaysia. For. Policy Econ. 2007, 9, 862–868. [Google Scholar] [CrossRef] [Scilit]
- Passer, A.; Lasvaux, S.; Allacker, K.; De Lathauwer, D.; Spirinckx, C.; Wittstock, B.; Kellenberger, D.; Gschösser, F.; Wall, J.; Wallbaum, H. Environmental Product Declarations Entering the Building Sector: Critical Reflections Based on 5 to 10 Years Experience in Different European Countries. Int. J. Life Cycle Assess. 2015, 20, 1199–1212. [Google Scholar] [CrossRef] [Scilit]
- Scrivener, K.L.; John, V.M.; Gartner, E.M. Eco-Efficient Cements: Potential Economically Viable Solutions for a Low-CO2 Cement-Based Materials Industry. Cem. Concr. Res. 2018, 114, 2–26. [Google Scholar] [CrossRef] [Scilit]
- Juenger, M.C.G.; Siddique, R. Recent Advances in Understanding the Role of Supplementary Cementitious Materials in Concrete. Cem. Concr. Res. 2015, 78, 71–80. [Google Scholar] [CrossRef] [Scilit]
- Zanelli, C.; Conte, S.; Molinari, C.; Soldati, R.; Dondi, M. Waste Recycling in Ceramic Tiles: A Technological Outlook. Resour. Conserv. Recycl. 2021, 168, 105289. [Google Scholar] [CrossRef] [Scilit]
- Testa, F.; Iraldo, F.; Frey, M.; Daddi, T. What Factors Influence the Uptake of GPP (Green Public Procurement) Practices? New Evidence from an Italian Survey. Ecol. Econ. 2012, 82, 88–96. [Google Scholar] [CrossRef] [Scilit]
- Sönnichsen, S.D.; Clement, J. Review of Green and Sustainable Public Procurement: Towards Circular Public Procurement. J. Clean. Prod. 2020, 245, 118901. [Google Scholar] [CrossRef] [Scilit]
- Chen, F.-Y.; Liang, J.-H. The Price Premium of Green Building Certification—A Case Study of New Taipei City Residential Building. J. Taiwan Land Res. 2018, 21, 61–85. (In Chinese) [Google Scholar] [CrossRef]
- Chen, Y.-A.; Su, F.-I.; Sun, C.-Y. Cost and Incentive Analysis of Green Building Label Upgrades in Taiwan’s Residential Sector: A Case Study of Silver to Gold EEWH Certification. Buildings 2025, 15, 2956. [Google Scholar] [CrossRef] [Scilit]
- Yau, J.-T.; Hsiao, L.-H. Industry Analysis and Management Strategy for Green Building Materials. J. Archit. 2008, 66, 35–46. (In Chinese) [Google Scholar]
- Tsai, W.-T. Interactive Analysis of Green Building Materials Promotion with Relevance to Energy Consumption and Greenhouse Gas Emissions from Taiwan’s Building Sector. Energy Build. 2022, 261, 111959. [Google Scholar] [CrossRef] [Scilit]
- Connelly, B.L.; Certo, S.T.; Ireland, R.D.; Reutzel, C.R. Signaling Theory: A Review and Assessment. J. Manag. 2011, 37, 39–67. [Google Scholar] [CrossRef] [Scilit]
- Cho, I.-K.; Kreps, D.M. Signaling Games and Stable Equilibria. Q. J. Econ. 1987, 102, 179–221. [Google Scholar] [CrossRef] [Scilit]
- Harbaugh, R.; Maxwell, J.W.; Roussillon, B. Label Confusion: The Groucho Effect of Uncertain Standards. Manag. Sci. 2011, 57, 1512–1527. [Google Scholar] [CrossRef] [Scilit]
- World Health Organization (WHO). WHO Guidelines for Indoor Air Quality: Selected Pollutants; WHO Regional Office for Europe: Copenhagen, Denmark, 2010. [Google Scholar]
- Farouk, A.M.; Omer, M.M.; Gadallah, A.G.; Farouk, M. An Integrated Framework for Indoor Air Quality in Saudi Arabia: A Systematic Literature Review. Phys. Chem. Earth 2027, 145, 104850. [Google Scholar] [CrossRef] [Scilit]
- Doan, D.T.; Ghaffarianhoseini, A.; Naismith, N.; Zhang, T.; Ghaffarianhoseini, A.; Tookey, J. A Critical Comparison of Green Building Rating Systems. Build. Environ. 2017, 123, 243–260. [Google Scholar] [CrossRef] [Scilit]
- Shan, M.; Hwang, B.-G. Green Building Rating Systems: Global Reviews of Practices and Research Efforts. Sustain. Cities Soc. 2018, 39, 172–180. [Google Scholar] [CrossRef] [Scilit]
- Institute for Building Environment and Energy Conservation (IBEC). CASBEE for Building (New Construction): Technical Manual, 2014 ed.; IBEC: Tokyo, Japan, 2014; Available online: https://www.ibec.or.jp/CASBEE/ (accessed on 1 October 2026).
- Ministry of Land, Infrastructure and Transport; Ministry of Environment. Green Standard for Energy and Environmental Design (G-SEED); Republic of Korea. Available online: http://www.gseed.or.kr/ (accessed on 1 October 2026).
- GB/T 50378-2019; Assessment Standard for Green Building; Ministry of Housing and Urban-Rural Development of the People’s Republic of China. China Architecture & Building Press: Beijing, China, 2019.
- Building and Construction Authority (BCA). Green Mark 2021; BCA: Singapore, 2021. Available online: https://www1.bca.gov.sg/ (accessed on 1 October 2026).
- German Sustainable Building Council (DGNB). DGNB System—Criteria Set New Construction, Buildings, Version 2023; DGNB: Stuttgart, Germany, 2023. [Google Scholar]
- U.S. Green Building Council (USGBC). LEED v4.1 Building Design and Construction; USGBC: Washington, DC, USA, 2019. [Google Scholar]
- Ministry of Finance; Ministry of Housing and Urban–Rural Development; Ministry of Industry and Information Technology of the People’s Republic of China. Notice on Further Expanding the Scope of Implementation of the Policy of Government Procurement Supporting Green Building Materials to Promote the Improvement of Building Quality (Caiku [2024] No. 36); Beijing, China, 31 December 2024. Available online: https://www.gov.cn/zhengce/zhengceku/202501/content_6997931.htm(In Chinese). (accessed on 8 November 2026).
- Anderson, J.; Moncaster, A. Embodied Carbon of Concrete in Buildings, Part 1: Analysis of Published EPD. Build. Cities 2020, 1, 198–217. [Google Scholar] [CrossRef] [Scilit]
- Stuart, E.A. Matching Methods for Causal Inference: A Review and a Look Forward. Stat. Sci. 2010, 25, 1–21. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schuirmann, D.J. A Comparison of the Two One-Sided Tests Procedure and the Power Approach for Assessing the Equivalence of Average Bioavailability. J. Pharmacokinet. Biopharm. 1987, 15, 657–680. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lakens, D. Equivalence Tests: A Practical Primer for t Tests, Correlations, and Meta-Analyses. Soc. Psychol. Personal. Sci. 2017, 8, 355–362. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Efron, B. Better Bootstrap Confidence Intervals. J. Am. Stat. Assoc. 1987, 82, 171–185. [Google Scholar] [CrossRef]
- Kennedy, P.E. Estimation with Correctly Interpreted Dummy Variables in Semilogarithmic Equations. Am. Econ. Rev. 1981, 71, 801. [Google Scholar]
- Cameron, A.C.; Miller, D.L. A Practitioner’s Guide to Cluster-Robust Inference. J. Hum. Resour. 2015, 50, 317–372. [Google Scholar] [CrossRef] [Scilit]
- Lundberg, S.; Marklund, P.-O.; Strömbäck, E.; Sundström, D. Using Public Procurement to Implement Environmental Policy: An Empirical Analysis. Environ. Econ. Policy Stud. 2015, 17, 487–520. [Google Scholar] [CrossRef] [Scilit]
- Jalaei, F.; Masoudi, R.; Guest, G. A Framework for Specifying Low-Carbon Construction Materials in Government Procurement: A Case Study for Concrete in a New Building Investment. J. Clean. Prod. 2022, 345, 131056. [Google Scholar] [CrossRef] [Scilit]
- U.S. General Services Administration (GSA). Inflation Reduction Act Low Embodied Carbon Concrete Requirements; GSA: Washington, DC, USA, 2023. Available online: https://www.gsa.gov/ (accessed on 1 October 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |