Abstract
Reinforced concrete (RC) frames with Autoclaved Aerated Concrete (AAC) infill are common in seismic regions, but the infill cracks at very small drifts and AAC-specific models are scarce. This paper presents a micro-to-macro modeling method based on experimentally validated micro-models and evaluates a dual strategy for reducing seismic vulnerability. A parametric study of 24 scaled frames (span, AAC thickness, and strength) provided calculation forms for the decoupled infill response; they define the AACF macro-model with Takeda column links and a central infill link with softening and cyclic degradation, consistent with the tested frame (peak +3.1%, error 6.8% of the peak). A five-storey frame was analyzed in OpenSees, base-fixed and isolated with sliding bearings and SF-ED devices, for one recorded and seven Eurocode 8 spectrum-compatible records scaled from 0.05 g to 0.80 g. The base-fixed frame reached the repairable infill drift (0.5%) at PGA = 0.17 g (recorded) and 0.24 g (spectrum-compatible), whereas with isolation the superstructure remained nearly elastic and the isolation displacement stayed within 160 mm up to about 0.55–0.7 g, depending on the device strength (6–12% of the weight) and the record. The planar analyses address one direction; the thresholds are specific to the example structure and input.
1. Introduction
Reinforced concrete (RC) frame buildings with masonry infill made of Autoclaved Aerated Concrete (AAC) elements are widely used in regions of moderate-to-high seismicity, particularly in South-East Europe and the Mediterranean. AAC is a lightweight cellular material characterized by low density, good thermal insulation, fire resistance, and ease of construction, making it suitable for enclosure and partition walls in framed buildings [1]. However, its mechanical behavior differs substantially from that of conventional fired-clay or concrete-block masonry. Experimental studies have shown that AAC generally exhibits relatively low compressive and tensile strength, reduced stiffness, and a brittle post-peak response [1,2]. Its physical and mechanical properties also depend on density, composition, and production technology, including the use of recycled AAC as a partial replacement material [3].
Although AAC infill walls are generally designed as non-structural components, they inevitably interact with the surrounding RC frame during earthquake loading. This interaction modifies the lateral stiffness, strength, energy dissipation, drift demand, and failure mechanism of the complete structural system. Post-earthquake observations have repeatedly demonstrated that masonry infills cannot be treated as inert mass. When panels are regularly distributed, they may reduce inter-storey drift and contribute positively to structural resistance. Conversely, irregular arrangements in plan or elevation may trigger soft-storey mechanisms, short-column effects, torsional response, and local shear failures [4,5]. The location of infill panels, the presence of openings, and the continuity of walls along the building height strongly influence the resulting seismic behavior [6].
Masonry infills are subjected to combined in-plane and out-of-plane demands. In-plane loading activates a diagonal compression mechanism, whereas out-of-plane loading may cause wall instability or expulsion. Damage accumulated during in-plane response can significantly reduce the remaining out-of-plane capacity, making the interaction between these two mechanisms particularly important for seismic safety [5,7]. These observations have motivated extensive research aimed at quantifying the contribution of masonry infills and developing reliable analytical models for structural assessment.
The analytical interpretation of infilled-frame behavior began with the work of Polyakov, who recognized that a laterally loaded panel separates from the surrounding frame near the tension corners and primarily resists loading through a diagonal compression field [8]. Holmes subsequently formalized this concept by replacing the panel with an equivalent diagonal strut [9]. Stafford Smith and Carter related the effective strut width to the relative stiffness of the frame and infill through a dimensionless interaction parameter [10,11], while Mainstone proposed empirical expressions that remain widely used in present-day assessment procedures [12]. These formulations established the foundation of macro-modeling approaches and continue to be attractive because of their simplicity and low computational demand.
The simplified equivalent-strut concept was extended to the inelastic range by Klingner and Bertero [13] and Saneinejad and Hobbs [14] and has gradually evolved to account for the highly nonlinear behavior observed during experimental testing. Panagiotakos and Fardis introduced multi-linear constitutive relationships capable of representing the cracking, peak-strength, and post-peak stages of masonry infills under seismic loading [15,16]. Their work demonstrated that the nonlinear response of infilled frames is strongly influenced by the degradation of stiffness and strength following the initiation of cracking. Subsequently, Dolšek and Fajfar incorporated these nonlinear characteristics into the seismic assessment of complete RC buildings and demonstrated that masonry infills significantly influence global lateral resistance, storey-drift distribution, and the development of soft-storey mechanisms [17].
Further improvements were achieved through the development of multi-strut macro-models. Crisafulli proposed a refined analytical formulation in which the masonry panel is represented by multiple interacting compression and shear components, allowing more realistic simulation of cyclic degradation and hysteretic behavior [18,19]. Other researchers introduced enhanced macro-models capable of considering frame–infill interaction, stiffness degradation, and different failure mechanisms while maintaining computational efficiency suitable for engineering applications [20,21]. Comprehensive reviews published by Asteris et al. [22] and Di Trapani et al. [23] clearly demonstrate that equivalent-strut models remain the most widely adopted approach for practical seismic assessment because they provide an appropriate balance between modeling simplicity and acceptable prediction accuracy. Their reliability has also been confirmed through comparisons with experimental results obtained from cyclic tests on masonry-infilled RC frames [24,25].
Recent research has increasingly focused on performance-based seismic assessment and fragility analysis of masonry-infilled RC buildings. Studies published in Buildings have investigated the influence of masonry infills on structural capacity, seismic vulnerability, and damage distribution using nonlinear numerical analyses and fragility methodologies [26,27,28]. These investigations confirmed that masonry infills substantially modify the seismic performance of RC buildings and should therefore be explicitly considered during structural assessment. Nevertheless, the majority of available macro-models have been developed and calibrated using conventional clay-brick or concrete-block masonry, while comparatively little attention has been devoted to AAC masonry systems.
At the opposite end of the modeling spectrum, detailed finite element micro-models explicitly represent masonry units, mortar joints, and frame–panel interfaces using nonlinear constitutive laws and interface elements [29,30,31]. Advances in computational mechanics have enabled the development of highly accurate three-dimensional finite element models capable of reproducing crack initiation, sliding, crushing, and interface debonding throughout the loading history [32,33,34,35]. Although these models accurately reproduce experimentally observed behavior, they require extensive material characterization, careful calibration of constitutive parameters, and considerable computational effort. Consequently, their practical application to complete multi-storey buildings remains limited, highlighting the need for simplified engineering models that preserve the essential nonlinear characteristics while maintaining computational efficiency.
Compared with conventional clay-brick masonry, the seismic behavior of Autoclaved Aerated Concrete (AAC) infill walls has received considerably less research attention despite the increasing use of AAC in modern energy-efficient buildings. The lower density, reduced elastic modulus, and lower compressive and tensile strengths of AAC significantly modify the interaction between the infill panel and the surrounding reinforced concrete frame. Consequently, modeling approaches and empirical parameters originally developed for conventional masonry cannot be directly transferred to AAC systems without appropriate experimental verification and recalibration [36,37,38].
Recent investigations have demonstrated that AAC infill walls exhibit different cracking mechanisms, stiffness degradation, and failure modes compared with traditional masonry. Experimental and numerical studies reported by Wang et al. [39], Li et al. [40], and Di Sarno and Albuhairi [41] confirmed that the nonlinear behavior of AAC panels is strongly influenced by material strength, panel thickness, and connection details, emphasizing the need for dedicated modeling approaches specifically developed for AAC masonry. The same need emerged from the authors’ own experimental and micro-modeling study of AAC-infilled RC frames, published in Civil Engineering Journal as the first part of this research [42].
Current seismic design standards acknowledge the influence of masonry infills but provide only limited guidance for explicitly modeling their structural contribution. Eurocode 8 considers the effects of masonry infills primarily through irregularity provisions, while Eurocode 6 focuses on the design of masonry elements without addressing their interaction with reinforced concrete frames [43,44]. Similarly, FEMA 306, FEMA 356, and ASCE/SEI 41 recommend equivalent-strut idealizations for seismic assessment but do not provide material-specific parameters for AAC masonry [45,46,47]. Consequently, practicing engineers frequently adopt parameters calibrated for conventional brick masonry, which may lead to inaccurate predictions of stiffness, strength, and deformation capacity when applied to AAC-infilled structures.
The vulnerability of AAC-infilled frames to strong earthquakes follows from the early cracking of the infill and the concentration of the deformation in the lowest storeys. In the tests and in the nonlinear analyses of the authors’ earlier work [42,48], the AAC panels cracked at drifts of a few tenths of one percent, far below the deformation capacity of the surrounding RC frame, and the five-storey frame analyzed with the macro-model developed in this paper developed a soft-storey mechanism in the first storey at a peak ground acceleration of 0.30 g. The bearing frame alone cannot prevent this damage in zones of high seismicity [48]. Three options for reducing the vulnerability can be distinguished: an adequate design of the RC frame, so that the interaction with the infill is safe; a local sliding or isolation interface between the frame and the infill; and base isolation of the whole building [48]. The first is attractive because it keeps the conventional structure, but it is effective only as long as the intensity of the earthquake is limited; the third changes the problem, because it removes most of the demand from the superstructure.
Seismic base isolation lengthens the fundamental period of the building and concentrates the displacement in a flexible layer between the foundation and the superstructure, which is then subjected to much smaller forces and drifts [49,50]. Sliding bearings with spherical surfaces carry the weight on a low-friction interface and provide a restoring force by the geometry of the surfaces [51,52], and they are used in buildings and bridges. However, in very strong earthquakes, their friction cannot by itself limit the displacement of the isolation level, which is bounded by the dimensions of the bearings and of the adjacent structure, and additional hysteretic dampers with a stable yielding mechanism are used for this purpose [53]. The choice of the strength of such dampers is a compromise: a large strength limits the displacement but transmits a larger force to the superstructure.
The authors’ group developed the multidirectional space-flange energy-dissipation (SF-ED) device, whose energy-dissipating components act in all horizontal directions, and an upgraded isolation system that combines it with double spherical sliding bearings and displacement-limiting buffers. The system was tested on shaking tables at large scale for bridges [54,55,56,57] and, at a scale of 1:4, for masonry and infilled-frame buildings [58,59]. These studies concern the performance of the isolation system itself; its combination with a nonlinear model of AAC infills, and the intensity of the earthquake from which isolation becomes necessary, have not been addressed. A model of the infilled frame that is simple enough for the dynamic analysis of complete buildings, and a quantitative delimitation of the ranges in which the design approach and isolation are appropriate, are therefore needed.
To address these needs, the present study proposes an integrated, experimentally validated micro-to-macro nonlinear modeling method for AAC-infilled RC frame buildings and uses it to evaluate a seismic vulnerability reduction strategy with two approaches, chosen according to the seismicity: (i) in zones of moderate seismicity, a design approach for the bearing RC frames that ensures a safe frame–infill interaction; (ii) in zones of high seismicity, seismic isolation that integrates base isolators with the novel SF-ED device, whose multidirectional behavior was established in previous tests and which is analyzed here in one horizontal direction. The proposed methodology combines experimentally validated nonlinear finite element models with a parametric investigation to derive practical macro-model parameters, and a five-storey frame is analyzed alternatively as base-fixed and as base-isolated, which makes it possible to delimit the ranges of application of the two approaches. Unlike the empirical formulations for conventional masonry, the proposed method establishes direct relationships between the characteristics of the AAC infill and the parameters of the model.
The principal scientific contributions of this study can be summarized as follows:
- Use of new, reliable and specifically targeted experimental data, recorded in the original tests on large-scale AAC-infilled RC frame models in the specially equipped ReSIN Laboratory [42] and in complex shaking-table tests on the original, novel isolated building model in the IZIIS Laboratory [58];
- Use of detailed nonlinear finite element models, validated against large-scale experimental tests [42], to conduct extensive numerical experiments in the integral parametric study;
- Comprehensive parametric investigation evaluating the influence of span length, wall thickness, and AAC compressive strength on structural response;
- Development of simplified interpolation equations for determining macro-model parameters of real-scale AAC-infilled RC frames within the investigated combinations;
- Proposal of a new AACF nonlinear macro-model, implemented using Takeda hysteretic links and a central nonlinear infill element within a conventional structural analysis platform [60,61];
- Verification of the proposed methodology through application to a multi-storey RC building, whose OpenSees implementation was verified against the SAP2000 analyses [48] and revised with P–Δ effects, softening and cyclic degradation of the infill and axial-load-corrected column links;
- Formulation of a dual seismic vulnerability reduction strategy: design rules for the bearing RC frames in zones of moderate seismicity and isolation with base isolators and SF-ED devices in zones of high seismicity;
- Nonlinear time-history analyses of the five-storey frame as base-fixed and base-isolated for 14 intensities of one recorded and seven spectrum-compatible accelerograms, with device parameters transferred from published tests, which quantify, for the example frame, the benefit of isolation, the role of the strength of the SF-ED devices and the ranges of application of the two approaches.
Relation to previous publications. The present paper builds on two earlier works of the authors, whose contents are separated as follows. (a) The test program on the 1:2 scale bare and AAC-infilled frames, the measured responses and the validation of the DIANA micro-models were published in Civil Engineering Journal [42]; they are only summarized here (Section 2). (b) The computed curves of the 24 parametric models, the decoupled infill parameters, the calculation forms, the AACF macro-model and the SAP2000 analyses of the base-fixed five-storey frame were developed in the doctoral dissertation [48], which is not a peer-reviewed journal publication; they are published here for the first time in a journal and are extended by the quantification of the uncertainty of the decoupling, an interpolation check and an explicit validity domain (Section 3.2, Appendix A), corrected parameter tables and a general step-by-step procedure (Section 3.3). (c) Entirely new are the infill link with softening and cyclic degradation (Section 3.3); the OpenSees implementation with P–Δ effects and axial-load-corrected column links, verified against SAP2000 and provided as scripts (Section 4.4, Supplementary Materials); the analyses of the base-isolated frame with SF-ED devices, the delimitation of the two approaches and the admissible range of the device strength (Section 5.8, Section 5.9, Section 5.10 and Section 5.11); and the analyses of the model refinements and of the record-to-record variability (Section 5.12 and Section 5.13). The properties of the isolation devices are taken from tests published by the authors’ group [54,55,56,57,58,59] and transferred to the building by similitude, so that the results on isolation are analytical and based on explicit assumptions (Section 4).
The remainder of this paper is organized as follows. Section 2 presents the test setup of the experimental basis with its analysis and the validated micro-models. Section 3 describes the parametric analyses, the uniform decoupling, the calculation forms, and the AACF macro-model with its application to a five-storey frame. Section 4 presents the seismic vulnerability reduction strategy, the isolation devices, and the OpenSees models, and Section 5 presents the results, from the verification of the models to the ranges of application of the two approaches. Section 6 discusses the findings and their limitations, and Section 7 summarizes the conclusions.
2. Materials and Methods
The study follows an integrated micro-to-macro method (Figure 1). In the first stage, nonlinear micro-models of the tested frames, validated against large-scale experiments [42], are used as “analytical experiments” in a parametric study. In the second stage, the results are decoupled into the response of the AAC infill, condensed into calculation forms for its governing parameters, implemented in a phenomenological macro-model (AACF), and applied to a five-storey frame. The third part uses this macro-model to evaluate a strategy for reducing the seismic vulnerability, with a design approach for zones of moderate seismicity and seismic isolation with SF-ED devices for zones of high seismicity (Section 4.1). The experiments and the micro-models (dashed boxes in Figure 1) were published in [42]; the parametric study, the decoupling, and the AACF model were developed in [48] and are extended here, and the analyses of Section 4 and Section 5 are new (see the end of Section 1). The experiments themselves are not repeated, but the test setup is described and analyzed (Section 2.1 and Section 2.2), because every numerical model has to reproduce its loading and boundary conditions. The micro-models were developed in DIANA FEA (DIANA FEA BV, Delft, The Netherlands), and the macro-models were analyzed in SAP2000 (Computers and Structures, Inc., Walnut Creek, CA, USA) and in OpenSees with its Python interface OpenSeesPy (Pacific Earthquake Engineering Research Center, University of California, Berkeley, CA, USA). The tests were carried out with the in-house testing system of the ReSIN Laboratory (Skopje, North Macedonia) described in [42].
Figure 1.
Workflow of the integrated method and strategy. Dashed boxes: stages reported previously [42,48]; the notes give the sections, figures, and tables of this paper in which each stage is described. The two approaches of the strategy are chosen according to the seismicity and are delimited by the analyses of Section 5.9.
2.1. Experimental Basis and Test Setup
The experimental basis is the test program on one-bay, one-storey RC frames at a scale of 1:2, carried out at the ReSIN Laboratory in Skopje and published in Civil Engineering Journal as the first part of this research [42] (see also [48]): two bare frames (M1-A, M1-B) and two frames filled with AAC blocks (M2-A, M2-B), each pair tested under cyclic (A) and monotonic (B) horizontal loading at a constant vertical load. As the frames are nominally identical, the difference between the bare and the infilled response is due to the infill alone. The monotonic envelopes serve as the reference for the micro-models (Section 2.3) and for the consistency check of the macro-model (Section 5.2); M1 and M2 denote the bare and the infilled specimens.
The tests were carried out in the self-contained testing system of the ReSIN Laboratory (Figure 2; components in Table 1), described in detail in [42]. Its reaction structure, a laboratory testing frame (LTF) of two parallel RC frames connected by a base beam, carries the specimen, whose RC footing is fixed to the base beam without a gap by threaded rods (MIS), so that the column bases are practically fully fixed, as assumed in the numerical models.
Figure 2.
Test setup at the ReSIN Laboratory, Skopje (schematic, dimensions in cm): (a) front view and (b) side view of the laboratory testing frame (LTF) with the AAC-infilled RC frame specimen, the vertical actuators applying the constant column loads N1 and the horizontal actuator applying the force F at the beam level; the numbered components are listed on the right (Table 1). Redrawn after [42,48].
Two vertical servo-hydraulic actuators (VHA, load control) apply the constant column loads N1 = 62.5 kN through hinges that do not restrain the horizontal displacement, and a horizontal actuator (HHA, displacement control, push–pull, ±300 kN, ±300 mm) imposes the displacement at the level of the top beam.
The specimens (Figure 3a,b, Table 2) have columns of 25 × 25 cm with a clear height of 130 cm and axes 200 cm apart, a T-section top beam, and a 265 × 55 × 40 cm footing. In the infilled specimen, the entire space between the columns, the beam, and the footing is filled with AAC blocks of 100 × 100 × 125 mm in thin-bed mortar, i.e., a 12.5 cm thick infill, which corresponds to 25 cm at full scale.
Figure 3.
Test specimen and test control: (a) geometry and reinforcement (the AAC infill is present only in specimen M2); (b) cross-sections of the beam, column (A–A) and footing (B–B); (c) control and measurement chain (TDIP, test data input port; LC, laboratory computer; EES, experiment execution system; VACS and HACS, vertical and horizontal actuator control systems; VASR and HASR, oil sources; VHA and HHA, hydraulic actuators; IS, instrumentation system; DAS, data acquisition system); (d) schematic loading history. Dimensions in cm.
Table 2.
Characteristics of the test specimens (scale 1:2); material properties are mean values of the tests reported in [42,48].
The test is executed fully automatically by a closed-loop control and data acquisition chain (Figure 3c; [42]); the forces and displacements are recorded at 10 Hz, so that the same loading history can be imposed in the numerical models.
The loading history (Figure 3d) has two phases. In the first phase, the vertical load is increased slowly and identically on both columns up to N1 = 62.5 kN, which is then kept constant. In the second phase, the horizontal displacement is imposed at the level of the top beam, quasi-statically: in one direction in the monotonic tests, and in successive positive and negative cycles of gradually increasing amplitude, with very small increments at the beginning in order to capture the initiation of cracking, in the cyclic tests. The horizontal force F is the load-cell force of the horizontal actuator, and the top displacement D is measured by the displacement transducers.
2.2. Analysis of the Test Setup
The setup was analyzed with three aims: to check that it loads and measures the specimen as assumed in the interpretation of the results (Table 3), to define how each of its features is reproduced in the numerical models (Table 4), and to define how the results of the scaled specimens are transferred to the prototype frames (Table 5).
Table 3.
Utilization and consistency checks of the test setup.
Table 4.
Correspondence between the features of the test setup and their representation in the numerical models.
Table 5.
Similarity relations between the scaled models (S = 1:2) and the prototype frames, with the values of the reference model M6-L1-G1-D1.
The horizontal actuator was loaded to only 27% of its force capacity (80.0 kN against ±300 kN) and to 7% of its stroke; even the largest force of the parametric models of Section 3.1 (about 121 kN) would use 40%, so that the setup does not limit the specimens of the study and stiffer or thicker infills could be tested with the same actuators. The vertical load of 62.5 kN per column corresponds to an axial load ratio of only 0.03, which is representative of the upper storeys of low- and mid-rise frames; by the similitude of Table 5 (forces × 4), it corresponds to 250 kN in the 50 × 50 cm prototype column, with the same axial load ratio, whereas the gravity loads of the columns of the five-storey frame are 112–560 kN; their effect on the column links is accounted for in Section 4.4. The largest imposed drift of 1.5% exceeds the displacement of the last point of the infill link of the single-storey macro-model (0.8% of the clear column height) and is of the order of the largest inter-storey drift of the five-storey frame (1.24%, Section 5.6). Because the actuator acts at the level of the top beam, the load-cell force equals the base shear of the frame, and the second-order effect of the vertical load path is at most about 3% of the peak force.
Every feature of the setup has a counterpart in the numerical models (Table 4): the rigid fixation of the footing by the MIS corresponds to fixed column bases, the two-phase loading history to two analysis phases (gravity load first, lateral loading afterwards), the displacement-controlled actuator to an imposed displacement at the beam level, so that the descending branch can be followed, and the force and the displacement recorded by the DAS to the reaction and the displacement of the control node. Only the frame–infill interaction cannot be reproduced one-to-one: it is represented by interface elements in the micro-models and by rigid diagonals and a single central link in the macro-model.
Because the specimens are scaled models, the results of the parametric analyses are transferred to the prototype frames through the similitude relations of Table 5. The scale is S = 1:2 with the same materials in the model and in the prototype, so that stresses are preserved: lengths and displacements are multiplied by 2, areas and forces by 4, the stiffness F/D by 2 and the energy, i.e., the area under the force–displacement curve, by 8. The spans of 200–300 cm and the infill thicknesses of 125–250 mm of the models therefore correspond to prototype spans of 400–600 cm and infill thicknesses of 250–500 mm, which is the practical range of the calculation forms of Section 3.2.
2.3. Nonlinear Finite Element Micro-Models
Nonlinear finite element micro-models of both specimens were developed in DIANA FEA [42]. Concrete and AAC masonry were discretized with eight-node plane-stress elements and described by the Total Strain Crack Model, the reinforcement as embedded bars with an elasto-plastic law and perfect bond, and the frame–infill interfaces and the thin-bed joints by zero-thickness interface elements based on the Lourenço–Rots multisurface model [62], which allow cracking, sliding, and separation. The analyses were displacement-controlled and monotonic, with a constant vertical load of 62.5 kN per column as in the tests (Table 4). Figure 4 compares the computed response of the infilled frame with the measured one up to the displacement of 8 mm reached in the test: both curves rise steeply and then follow a broad plateau around the maximum force; the computed peak force of 82 kN exceeds the measured 80.0 kN by about 2.5%, and after the peak the measured strength decreases faster than the computed one (about 50 kN measured against about 62 kN computed at 8 mm). Beyond the tested range, the micro-model (dashed line) continues to a displacement of 20 mm with a slowly decreasing strength of 55 to 43 kN. The micro-models thus reproduce the initial stiffness, the peak resistance and the onset of softening of the tested frame; the constitutive parameters, the calibration and the complete validation, including the bare frame and the crack patterns, are given in [42]. They were used as numerical experiments in the parametric analyses of Section 3.1.
Figure 4.
Comparison of the measured (specimen M2) and computed load–displacement response of the AAC-infilled RC frame. The shaded area is the displacement range reached in the test; the dashed line is the computed response beyond that range. Experimental and numerical results from [42].
3. Parametric Analyses and Development of the AACF Macro-Model
All parametric analyses were carried out on scaled RC frame models (S = 1:2) under the conditions of the tests: a constant vertical load of N1 = 62.5 kN per column and monotonic displacement-controlled horizontal loading at the beam level (Figure 2, Table 4). Three spans (L = 200, 250 and 300 cm), three infill thicknesses (D = 125, 200 and 250 mm) and three AAC strengths (G = 2.5, 3.75 and 5.0 MPa) were combined according to Table 6, which, together with the bare-frame cases, comprises twenty-four models. The bare frame of each span (type M5 = M0) is required for the decoupling of Section 3.2. The study had two objectives: to isolate the nonlinear contribution of the AAC infill from the response of the surrounding frame, and to express it by a small number of parameters that depend on L, D and G through simple calculation forms.
Table 6.
Matrix of the twenty-four representative RC frame models of the parametric study (scaled models and corresponding prototype values).
Forces F are given in kN and displacements in mm. In the model designation M-L-G-D, M is the model type (M1–M8; these are not the specimens M1 and M2 of Section 2.1), L the span, G the AAC compressive strength, and D the infill thickness. In the relations proposed here, an unsubscripted D is the thickness of the infill, whereas subscripted symbols denote displacements (DY, DM, DU, DL) and forces (FY, FM, FU, FL) at the characteristic points of an envelope: Y is the point of significant stiffness change, M (or U) the point of maximum strength, and L the last point. The scaled models are identified by their designation, and the prototype frames by their span (400–600 cm) and thickness (250–500 mm).
3.1. Computed Responses of the Parametric Models
Figure 5 shows the computed force–displacement responses of the scaled models, re-plotted from the results of the parametric analyses [48] (the values quoted below are read from the curves with an uncertainty of about ±2 kN; the effect of the span is shown in Figure 6). In every model, the infill raises the strength of the frame above that of the bare frame, which is practically independent of the span (Figure 6b), reaches about 62 kN at 3–4 mm and decreases to about 50 kN beyond 10 mm. The curves of the infilled frames rise steeply, reach their maximum at a top displacement of 3–9 mm (0.2–0.7% of the clear column height) and then decrease slowly.
Figure 5.
Computed force–displacement responses of the scaled AAC-infilled RC frames (re-plotted from the parametric analyses of [48]): (a–c) effect of the infill thickness D (G = 2.5 MPa) for the spans L = 200, 250 and 300 cm; (d–f) effect of the AAC strength G (D = 125 mm). Dotted line: bare frame; thin red line in (a): measured response of the tested specimen. Models M1–M3 and M6–M8 of Table 6.
Figure 6.
Effect of the frame span: (a) responses of the infilled frames with D = 125 mm and G = 2.5 MPa for the spans L = 200, 250 and 300 cm, compared with the response of the bare frame and with the experiment (L = 200 cm); (b) response of the bare RC frames (model M5 = M0) up to 20 mm, which is practically independent of the span in the studied range.
The thickness of the infill has the largest influence (Figure 5a–c). For L = 200 cm, the increase in D from 125 to 200 and 250 mm raises the peak force from 77 to 110 and 121 kN and shifts the peak from about 3 mm to about 6 mm; for L = 250 cm the peak force is 74, 80 and 111 kN, and for L = 300 cm it is 72, 81 and 111 kN, i.e., the intermediate thickness is much less effective in the longer frames. The strength of the AAC has a smaller, span-dependent effect (Figure 5d–f): at L = 200 cm the peak force increases from 78 to 83 and 90 kN when G is increased from 2.5 to 3.75 and 5.0 MPa, whereas at L = 250 and 300 cm it varies only between 75 and 80 kN and between 73 and 75 kN, which is within the reading uncertainty. With increasing span, the peak force of the reference infill decreases slightly (77, 74 and 72 kN for L = 200, 250 and 300 cm) and is reached at larger displacements (3.1, 4.1 and 6.7 mm), i.e., the initial stiffness decreases markedly. The model with L = 200 cm, D = 125 mm and G = 2.5 MPa reproduces the measured response of the tested frame; its computed peak of 77 kN is 3% below the measured peak of 80 kN.
3.2. Uniform Decoupling Methodology and Macro-Model Parameters
For every model, the nonlinear response of the AAC infill was decoupled by subtracting the computed response of the corresponding bare RC frame from that of the infilled frame at the same top displacement x (Equation (1)), where FIF and FBF are the horizontal forces of the infilled and of the bare frame, and FAAC is the apparent contribution of the infill. Because the column links of the AACF model are calibrated on the bare frame and act in parallel with the infill link under the same storey drift, Equation (1) defines exactly the force that the infill link has to carry for the model to reproduce the infilled frame. FAAC therefore contains the frame–infill interaction, i.e., the change in the column forces caused by the infill, and is not an intrinsic force–displacement law of the infill alone; it is valid for frames similar to the analyzed ones (same columns, reinforcement and axial load ratio of 0.03), and its transfer to frames with different stiffness, reinforcement or axial load has not been verified.
The decoupled envelope was idealized with the same procedure for all models (Figure 7, reference case L1 = 200 cm, D1 = 125 mm, G1 = 2.5 MPa; panel a places the decoupled response next to the responses of the infilled frame and of the bare frame, panel b shows the idealization). The governing point M is defined by the maximum force FM and its displacement DM. Below DM, the envelope is the second-order parabola of Equation (2), whose coefficients (Equation (3)) follow from the conditions that it passes through M and has a horizontal tangent there.
Figure 7.
Decoupling and idealization of the AAC infill response for the reference frame (L1 = 200 cm, D1 = 125 mm, G1 = 2.5 MPa): (a) responses of the experiment and of the micro-models with three infill thicknesses, with the bare-frame and decoupled infill-only responses; (b) idealization of the decoupled response by the parabola of Equation (2) up to point M and by the descending line of Equation (5) to point L (dashed line: tangent at the origin).
The initial stiffness K0 is the tangent of the parabola at the origin, i.e., the coefficient b. Point Y, marking a significant change in stiffness, is placed on the parabola at DY = 0.5 DM (Equation (4)), which gives FY = 0.75 FM. The ratios DY/DM = 0.5 and FY/FM = 0.75 are therefore not independent assumptions but properties of the parabola with a horizontal tangent at M.
Beyond DM, the envelope is the descending straight line of Equation (5), which ends at point L with DL = 2.5 DM and FL = 0 (Equation (6)). The ratio DL/DM = 2.5 corresponds to the displacement at which the decoupled contribution of the reference model vanishes, i.e., at which the infilled response approaches that of the bare frame (Figure 7a).
The entire nonlinear envelope of the infill is thus reconstructed from only two governing quantities, FM and DM; the ratios DY/DM = 0.5, FY/FM = 0.75 and DL/DM = 2.5 were fixed for all models, so that the shape of the envelope is the same for every combination of span, thickness and strength (the influence of these choices on the response of the five-storey frame is quantified in Section 5.12).
The idealization was applied to the eighteen infilled models of Table 6 (M1–M3 and M6–M8). Table 7 lists their governing parameters for the scaled models and, through the similitude of Table 5, for the prototype frames, and Figure 8 shows the idealized envelopes. For the scaled models, FM ranges from 10 to 58 kN and DM from 3.0 to 6.2 mm; the prototype values are FM = 40–232 kN and DM = 6.0–12.4 mm. In the thickness series (M1–M3), FM increases with the thickness at every span, whereas in the strength series (M6–M8), the effect of the strength decreases with increasing span; for the longest span, the models with G = 2.5 and 3.75 MPa (M8) were analyzed with identical parameters. The reference configuration is contained in both series, with FM = 21 kN in the thickness series (M1-L1-G1-D1) and 17 kN in the strength series (M6-L1-G1-D1), i.e., 19 kN ± 11%. The difference follows from the decoupling itself: FAAC is the difference in two forces of similar magnitude (about 77–80 kN for the infilled and 60 kN for the bare frame at DM ≈ 4 mm), so that a reading uncertainty of ±2 kN on each computed curve (Section 3.1) gives up to ±4 kN on FAAC, i.e., ±19–24% for the reference infill and up to about ±40% for the weakest infills (FM = 10–13 kN), but only ±7–10% for the thick ones (FM = 47–58 kN). A change in the frame contribution caused by the infill is transferred one-to-one to FAAC: a change of only 5% of the frame force (3 kN) changes FAAC of the reference infill by 14%. Form 1 at 400 cm uses the value of the strength series (68 kN in the prototype), so that Forms 1, 4 and 5 come from the same series, whereas the five-storey model uses 84 kN (4 × 21 kN), consistent with the infill link calibrated on the experiment (Section 3.3); the effect of this difference on the dynamic response is negligible (Section 5.12).
Figure 8.
Idealized decoupled responses of the AAC infill of the scaled models according to Equations (2)–(6), with the parameters of Table 7: (a–c) infill thickness D = 125, 200 and 250 mm for the spans L = 200, 250 and 300 cm; (d–f) AAC strength G = 2.5, 3.75 and 5.0 MPa for the same spans. Open circles: point M (maximum force); squares: point Y.
Table 7.
Governing macro-modeling parameters of the decoupled AAC infill for the eighteen infilled models: scaled models and prototype frames.
Figure 8 shows the idealized envelopes of the decoupled infill of all eighteen models, obtained with Equations (2)–(6) from the parameters of Table 7: in the thickness series (Figure 8a–c) the maximum force increases with the thickness at every span, and in the strength series (Figure 8d–f) the effect of the strength decreases with the span; for the longest span the two models with G = 2.5 and 3.75 MPa have identical parameters (FM = 10 kN, DM = 5.1 mm), so that their curves coincide in Figure 8f.
To make the procedure directly usable in practice, FM and DM of the prototype frames were expressed as linear functions of the span L (Equation (7)) in two ranges, 400–500 cm and 500–600 cm, because the response does not vary linearly over the whole range, separately for each infill thickness and strength. The five resulting calculation forms are given in Table 8 and illustrated in Figure 9 for the prototype spans of 400, 500 and 600 cm (the corresponding characteristic points are tabulated in Table 9); Form 1 at 400, 500 and 600 cm reproduces the models M6-L1-G1-D1, M2-L2-G1-D1 and M3-L3-G1-D1. The accuracy of the linear interpolation was checked by a leave-one-out test (Appendix A, Table A1): a single linear relation over 400–600 cm would be in error by up to 58% (Form 2), and the response is strongly nonlinear in thickness, so that the two span segments are necessary; the interpolation error inside a segment may reach 10–20%, and no interpolation in thickness or strength is admissible.
Table 8.
Practical calculation forms for the governing macro-modeling parameters FM and DM of the decoupled AAC infill (prototype frames).
Figure 9.
Maximum force FM (a,b) and corresponding displacement DM (c,d) of the decoupled AAC infill for prototype spans of 400, 500 and 600 cm: (a,c) effect of the infill thickness D at G = 2.5 MPa; (b,d) effect of the AAC strength G at D = 250 mm (values of the forms of Table 8).
Table 9.
Macro-modeling parameters of the decoupled AAC infill computed from the forms of Table 8 for prototype spans of 400, 500 and 600 cm.
Table 9 lists FM, DM, and the derived characteristic points obtained from the forms at the three prototype spans. For a given span, FM varies by a factor of 3.4 to 4.3 between the thinnest and the thickest infill (L = 400 cm: 68 to 232 kN; L = 600 cm: 44 to 188 kN), whereas DM remains between 6.0 and 12.4 mm in all cases.
As a worked example, for a frame with L = 550 cm, D = 250 mm and G = 2.5 MPa, Form 1 for the range 500–600 cm gives FM = −0.08 × 550 + 92 = 48 kN and DM = 0.01 × 550 + 5 = 10.5 mm, and hence DY = 5.25 mm, FY = 36 kN, DL = 26.25 mm and K0 = 2 × 48/10.5 = 9.14 kN/mm (see Section 3.3). Unlike conventional equivalent-strut formulations, which provide empirical stiffness relationships for a limited range of masonry systems, the forms give the governing nonlinear parameters for AAC-infilled RC frames directly, so that repeated detailed finite element analyses are avoided, while consistency with the experimentally validated numerical models is maintained within the investigated parameter range.
3.3. The AACF Phenomenological Macro-Model
The parametric results provided the basis for a new phenomenological nonlinear macro-model of AAC-infilled RC frames, referred to as the AACF model (AAC frame), shown for one storey in Figure 10. The beams are assumed to be rigid, each column contains a nonlinear link element, and the AAC infill is idealized by a single central nonlinear link, connected to the surrounding frame through rigid diagonal members. The diagonals form two stiff triangular sub-assemblies, above and below the link, so that the in-plane forces are transferred to the link without artificial tensile resistance or additional deformation mechanisms: the storey displacement is imposed on the link as the relative displacement of its end nodes, and the link force is the force carried by the infill. In single- and multi-strut models [12,13,14,15,16,17,18,19], the infill is a compression-only diagonal whose axial law follows from an assumed strut width, inclination, and masonry modulus, and whose forces enter the beam–column joints. In the AACF model, the rigid diagonals impose the storey drift directly on one central shear link whose law is the decoupled lateral response of the AAC infill (Equation (1)), so that no strut width, angle, or compression-only rule is needed; in a shear-building idealization, both approaches give the same storey response for the same lateral backbone, and the difference lies in how the backbone is obtained. The relevance of an AAC-specific backbone is illustrated by the equivalent strut of ASCE/SEI 41 [47] (Mainstone width, Eme = 550 f′m) computed for the tested specimen (f′m = 2.64 MPa, t = 125 mm; indicative values): it gives a lateral stiffness of 15.9 kN/mm and a strut crushing capacity of 78 kN, against 10.5 kN/mm (K0) and 21 kN (FM) of the decoupled AAC infill, i.e., the generic strut, calibrated mainly on clay-brick and concrete-block masonry, overestimates the stiffness by about 50% and the strength by a factor of about 3.7. The AACF model is derived from experimentally validated micro-models through the decoupling of Section 3.2, and it requires far fewer parameters and much less computational effort than micro-modeling, which makes it suitable for nonlinear static and dynamic analyses of complete multi-storey buildings. It was developed and verified in SAP2000 [61], re-implemented in OpenSees for the analyses of Section 4.4, and can be implemented in any software that supports nonlinear link elements.
Figure 10.
Concept of the AACF macro-model for one storey: rigid beam, RC columns linked with the Takeda hysteretic model, and a single central nonlinear AAC infill link connected to the frame through rigid diagonals (two stiff triangular sub-assemblies).
The nonlinear behavior of the RC columns was represented with link elements governed by the Takeda hysteretic model [60], which reproduces the stiffness degradation and the energy dissipation of RC members under cyclic loading (its rules are summarized in Section 5.5). The AAC infill link was defined directly from the decoupled envelope. In the original model, used in SAP2000 [48] and for the verification of the OpenSees model (Section 5.7), the softening branch was omitted, and the force was kept constant at FM up to DL. In the revised OpenSees model, the infill link follows the complete envelope: the ascending branch to U, linear softening to a residual strength of 10% of FM, reached at DM + 0.9(DL − DM) (9.4 mm in the scaled model), and a constant residual branch. Its cyclic behavior is described by the Pinching4 law [63]: reloading is pinched towards a point at 40% of the largest previous deformation and 20% of the corresponding force, and the unloading stiffness, the reloading stiffness, and the strength degrade as functions of the dissipated hysteretic energy. The envelope comes from monotonic analyses, and the cyclic parameters, typical values for masonry infills, were not calibrated on cyclic test data; their influence is quantified in Section 5.12, and the cyclic response is compared with the cyclic test M2-A in Appendix B. The initial branch of the infill link is the secant to point Y, FY/DY = 0.75K0, which passes through the characteristic point Y; its effect compared with the tangent K0 is also quantified in Section 5.12. The characteristic points of both links are shown in Figure 11 and, for the single-frame model, listed in Table 10.
Figure 11.
Backbone curves of the nonlinear links of the verification model (Table 10): (a) RC column link (both columns together) with points Y, U and L; (b) AAC infill link with points Y, U and L (softening branch omitted).
Table 10.
Nonlinear link parameters of the AACF model calibrated for the tested single-frame model (scale 1:2).
The calibration of the AACF model for a given frame is summarized as a step-by-step procedure in Table 11, together with the values of the worked example (L = 550 cm, D = 250 mm, G = 2.5 MPa). Steps 1 to 5 are hand calculations that require only the span, the thickness, and the strength of the infill; steps 6 and 7 are the assembly and the analysis of the model in the structural analysis software.
Table 11.
Step-by-step procedure for defining the AACF macro-model of an AAC-infilled RC frame, with the values of the worked example.
3.4. Multi-Storey Application and Ground Motions
To demonstrate the practical applicability of the methodology, the AACF model was implemented in a representative five-storey RC building, idealized as a planar single-bay frame (Figure 12). The columns have a constant cross-section of 50 × 50 cm, the AAC infill is 250 mm thick at every storey, the storey height is 3.0 m, and the span between the column axes is 4.0 m. The beams were modeled as rigid because their flexural behavior is implicitly incorporated into the calibrated force–displacement relationships of the links. The gravity load of 224 kN per bay was applied as two concentrated loads of 112 kN at each storey level, which gives a total weight of about 1120 kN (114.2 t); the column bases are fixed, the gravity axial forces of the columns are 112, 224, 336, 448 and 560 kN in storeys 5 to 1 (axial load ratio up to about 0.07–0.09 at the base), whereas the test conditions (62.5 kN in the scaled column) correspond by similitude to 250 kN in the prototype column (Table 5); the column links calibrated under the test conditions are corrected for the actual axial loads in the revised model (Section 4.4). Geometric (P–Δ) nonlinearity was included in the SAP2000 analyses of [48] and in the revised OpenSees model.
Figure 12.
AACF model of the five-storey RC frame with AAC infill (left of the isolation layer, the base-fixed model): two RC column links, a central AAC infill link, rigid beams and rigid diagonals at each storey; the labels are the link identifiers of the SAP2000 model [48] and the parameters of the links are given in Table 12.
Each storey consists of two RC column links acting in parallel with one AAC infill link, so that the storey shear is the sum of the forces of the three links (Table 12). The column links have the same yield point at all storeys (DY = 3.6 mm, FY = 72 kN, K0 = 20 kN/mm) and a maximum strength FU that decreases from 110 kN at the first to 90 kN at the fifth storey; the infill links are identical at all storeys (K0 = 15.75 kN/mm, 28% of the initial stiffness of a storey). The deformation limits adopted for the links are Df = 30 mm for the RC columns and Df = 15 mm for the AAC infill; they are used in Section 5.5 and Section 5.6 to assess the damage. In terms of drift, three indicators are used in Section 5.9, Section 5.10, Section 5.11, Section 5.12 and Section 5.13: 0.13% (4 mm), the point Y of the decoupled AAC envelope at which its stiffness changes significantly, as the limit of practically undamaged infill; 0.5%, the damage-limitation drift of EN 1998-1, 4.4.3.2 [43] for buildings with brittle non-structural elements attached to the structure, as the limit of repairable infill damage (it also corresponds to Df = 15 mm of the infill link); and 1.0% (Df = 30 mm), between the maximum-strength point (0.67%) and the last point (1.32%) of the column links and of the order of the significant-damage drift of non-ductile RC frames in ASCE/SEI 41 [47], as an indicative limit of the columns. These limits serve to compare systems and are not acceptance criteria.
Table 12.
Parameters of the nonlinear links of the five-storey AACF model (values per link).
The seismic excitation was the horizontal component of the Ulcinj–Albatros earthquake record, amplitude-scaled to two peak ground acceleration (PGA) levels of 0.22 g and 0.30 g to evaluate the influence of the earthquake intensity on the nonlinear response (Figure 13). The scaling modified only the amplitude and preserved the frequency content and the duration; the strong-motion phase lasts from about 5 s to about 16 s. The nominal PGA refers, as in [48], to the largest positive acceleration; the largest absolute (negative) acceleration is 1.091 times larger (−0.24 g and −0.33 g), so that all intensities can be converted to the absolute PGA by this factor. The record was digitized from the plot of [48] at Δt = 0.01 s (30 s) and checked against the annotated peak values and their times; it is retained in this form because the SAP2000 analyses of [48] are the reference for the verification of the OpenSees model (Section 5.7), and it is provided as Supplementary Material S2. To assess the record-to-record variability, seven artificial accelerograms compatible with the elastic spectrum of EN 1998-1 [43] (Type 1, ground type B, 5% damping) were generated by iterative correction of the Fourier amplitudes of enveloped random-phase signals [64] (duration 25 s, strong phase 10 s; response spectra computed with the algorithm of [65]). Their mean spectrum lies between 91.5% and 97% of the target from 0.09 s (0.2 T1 of the base-fixed frame) to 5 s, beyond the effective periods of the isolated systems, which satisfies the 90% rule of EN 1998-1, 3.2.3.1.2 (Section 5.13); for these records, the PGA is the largest absolute acceleration.
Figure 13.
Horizontal acceleration time-history of the Ulcinj–Albatros earthquake scaled to (a) PGA = 0.22 g and (b) PGA = 0.30 g. The marked points are the largest positive and negative accelerations.
The SAP2000 analyses of [48] are the reference for the dynamic response of the five-storey frame (Section 5.3, Section 5.4, Section 5.5 and Section 5.6); their results are used here in the form in which they are reported (peak values, response plots and hysteresis loops). The same frame is analyzed with OpenSees in Section 4.4, after verifying that this model reproduces the SAP2000 results (Section 5.7), in order to include the isolation layer. The integration scheme, the time step, and the damping of the SAP2000 analyses are not given in [48]; the settings of the OpenSees analyses are given in Section 4.4.
4. Seismic Vulnerability Reduction Strategy
4.1. Concept: Two Approaches According to the Seismicity
The experimental and numerical results on AAC-infilled frames [42,48] show that the infill raises the stiffness and the strength of the frame, but that it cracks early (the yield deformation of the infill link is only 4 mm, 0.13% of the storey height) and that its deformation limit in the model is 15 mm (0.5%); its damage cannot be avoided in zones of high seismicity by the bearing frame alone [48]. The options for reducing it are an adequate design of the RC frame, local sliding or isolation between the frame and the infill, and base isolation of the whole building [48]. Two of them are developed here as a strategy with two approaches, chosen according to the seismicity (Figure 1): in zones of moderate seismicity the infill is kept and the bearing RC frame is designed so that the frame–infill interaction is safe (Section 4.2); in zones of high seismicity, where very strong earthquakes are expected, the building is seismically isolated by an isolation system that integrates base isolators with space-flange energy-dissipation (SF-ED) devices, whose multidirectional behavior was established in previous shaking-table tests [54,55,56,57,58] (Section 4.3), which keeps the superstructure, and thus the infill, nearly elastic. Both approaches are evaluated with the same AACF macro-model (Section 4.4), which makes it possible to delimit their ranges of application quantitatively (Section 5.9).
4.2. Design Approach for the Bearing RC Frames in Zones of Moderate Seismicity
In zones of moderate seismicity, repairable damage of the infill is acceptable, but its failure must not endanger the bearing frame. The approach has five rules, whose numerical values are those of the frame analyzed here (Section 3.4 and Section 5). (i) The infill is modeled explicitly with the AACF link and the calculation forms of Table 8, instead of a bare-frame model: it provides 28% of the initial storey stiffness and carries 27–34% of the storey shear in the SAP2000 analyses [48]. (ii) The storey drift is checked against three limits: the yield of the infill (4 mm, 0.13%), the end of its plateau (15 mm, 0.5%), and the deformation limit of the RC columns (30 mm, 1.0%); the first limit marks the onset of infill cracking, the second its repairable damage, and the third the safety of the frame. (iii) The columns are designed with capacity design for the state after the loss of the infill, with the shear and the ductility needed to carry the storey shear without the infill link, which is verified by a bounding analysis. (iv) The first storey, in which the deformation concentrates (Section 5.4), receives a strength and a stiffness that avoid a soft-storey mechanism. (v) The axial load of the columns is limited to about 20–25% of their axial capacity, so that the favorable contribution of the infill is used without reducing the ductility of the columns [48]. The range of application is given by the PGA at which the base-fixed frame reaches the limits of rule (ii) (Section 5.9); beyond it, the second approach is adopted. The five rules are formulated from the findings of [42,48] and of this paper.
4.3. Seismic Isolation with SF-ED Devices for High-Seismicity Zones
Seismic isolation lengthens the fundamental period and concentrates the displacement in a flexible layer, so that the superstructure is subjected to much smaller forces and drifts [49,50] (Eurocode 8, Part 1, Section 10 [43]). Sliding and rolling bearings with spherical surfaces carry the weight and provide a restoring force [51,52], but their friction cannot by itself limit the isolation displacement in very strong earthquakes, for which hysteretic dampers are added [53]. The authors’ group developed the SF-ED device, a steel device whose energy-dissipation (ED) components are arranged radially so that its response is the same in all horizontal directions, and combined it with double spherical sliding or rolling bearings into an upgraded isolation system, which was tested on shaking tables for bridges [54,55,56,57] and, at a scale of 1:4, for masonry and infilled-frame buildings [58]. The isolation system for buildings consists of sliding isolation, SF-ED devices, and displacement-limiting devices (rubber buffers) [58,59]. In the building tests, the isolation by the bearings alone reached 42.6 mm at the strongest record (Petrovac, 0.47 g), above the allowable displacement of the bearings of 40 mm, whereas with the SF-ED devices the peak displacement was 24.2 mm against 42.6 mm with the bearings alone) and, for all four records, at most 34.3 mm [58]. For the bridge model, bilinear models of the bearings and of the SF-ED devices reproduced the measured peak displacements within 8–11% [56]. The present analyses consider one horizontal direction only (Section 4.4); the multidirectional behavior of the device rests on these tests.
The tests were carried out on scaled models, so that the parameters of the devices (Table 13) are transferred to the five-storey frame by the similitude of the building model (scale factor λ = 4 [58]), Equation (8): lengths and displacements are multiplied by 4, forces by 16 and stiffness by 4, whereas the friction coefficient and the hardening ratio are unchanged (Figure 14b,c). The index t denotes the tested device. The bearings are represented by a bilinear friction law normalized by the vertical load N, and the SF-ED device by its bilinear kinematic-hardening law.
Table 13.
Parameters of the isolation devices: tested devices (published) and prototype devices adopted in the analyses of the five-storey frame.
Figure 14.
Model of the base-isolated five-storey frame: (a) AACF frame on a rigid base slab, with the isolation layer formed by the double spherical sliding bearings (DSSSB) and the SF-ED device; (b) force–displacement law of the bearings (normalized by the vertical load N), with the tested 1:4 model for comparison; (c) laws of the SF-ED devices (4C: reference; 8C: sensitivity analysis only), scaled by the similitude of Equation (8); (d) total force of the isolation level normalized by the weight W for the three systems analyzed, with the yield shear of the first storey and the allowable displacement Da (Table 13).
The number of SF-ED devices is expressed by the ratio ψ of their total yield force to the supported weight W (Equation (9)); the bridge test [56] used two devices with a yield force of 9 kN each. The parameters of Table 13 are those published for the tested devices, scaled by similitude; they are not the parameters of devices designed for the building, whose number is varied through ψ in Section 5.10.
4.4. Numerical Models of the Base-Fixed and the Base-Isolated Frame (OpenSees)
The five-storey AACF frame was re-implemented in OpenSees [66,67] as a planar model with one lateral degree of freedom per storey; the scripts are provided as Supplementary Material S1. The RC column links and the infill link of every storey are zero-length elements. Two versions are used. The original model reproduces the SAP2000 model of [48]: “Hysteretic” materials with the backbones of Table 12, a Takeda-type rule [60] for the column links (peak-oriented reloading, unloading stiffness degraded with an exponent of 0.2), a peak-oriented rule without degradation and without softening for the infill links, no P–Δ effects and Rayleigh damping of 8%; the exponent and the damping ratio were calibrated to reproduce the SAP2000 results (Section 5.7), whose Takeda parameters and damping are not given in [48]. The revised model, used for all results of Section 5.8, Section 5.9, Section 5.10, Section 5.11, Section 5.12 and Section 5.13 unless stated otherwise, differs in four respects (Section 5.12): (i) the infill links have the softening envelope and the Pinching4 cyclic law of Section 3.3; (ii) P–Δ effects are included by a geometric stiffness of −P/h in each storey, with the gravity load P carried by the storey; (iii) the yield and maximum forces of the column links are multiplied by factors that account for the actual gravity axial forces of the columns (112–560 kN), obtained from a fiber-section moment–curvature analysis of the prototype column (50 × 50 cm, 4Ø24 + 4Ø20, Concrete02 and Steel02 materials): relative to the 250 kN corresponding to the test conditions, the yield moment changes by factors of 0.935, 0.990, 1.044, 1.096 and 1.147 and the maximum moment by 0.955, 0.991, 1.023, 1.051 and 1.073 from storey 5 to storey 1; the variation in the axial forces caused by overturning changes the sum of the capacities of the two columns of a storey by only about 4%, because the gain of one column largely offsets the loss of the other, so that constant gravity factors are adequate for the planar model; (iv) the damping ratio of the superstructure is 5% (2% and 3% in the sensitivity analysis, Section 5.11). In both versions, the mass is 22.8 t per storey (224 kN) and the Rayleigh damping, proportional to the mass and to the initial stiffness and defined in modes 1 and 3 of the base-fixed frame, is applied to the superstructure only: the stiffness-proportional part acts on the links of the superstructure and the mass-proportional part through dashpots that connect the storey masses to the base node, so that the rigid-body motion of the isolated structure does not produce damping forces. The equations of motion are integrated with the Newmark average-acceleration method [68] with a time step of 0.0025 s and Newton–Raphson iterations. The fundamental period is 0.447 s for the original and 0.435 s for the revised model.
For the base-isolated variant, the isolation layer was placed between the foundation and a rigid base slab, with the bearings and the SF-ED devices as zero-length elements in parallel (bilinear kinematic-hardening material) and the laws of Table 13; at the displacement D, the force of the layer is the sum of the force of the bearings and of the devices (Equation (10)). The bearings carry the supported weight W = 1232 kN (frame 1120 kN plus the base slab, whose mass was adopted as 11.4 t, half of a storey mass). Three isolation systems were analyzed: bearings only (ψ = 0), bearings with one SF-ED device (reference, ψ = 11.7%, yield force 144 kN), with two devices (ψ = 23.4%), and, as an alternative, with devices of ψ = 6%. The laws continue with their post-yield stiffness beyond DU = 200 mm, and the displacement-limiting buffers [58,59] are not modeled; the allowable displacement is Da = 160 mm.
The force transmitted by the isolation level is limited by its strength, which is about 4.3% of W for the bearings (μu, Table 13) plus ψ W for the devices. For the superstructure to remain elastic this force should not exceed the yield shear of the first storey, Vy,1 = 2 × 72 + 63 × 3.6/4.0 = 200.7 kN for the original model, i.e., 16.3% of W (at the yield of the columns, 3.6 mm, the infill carries 56.7 kN), and Vy,1 = 2 × 72 × 1.147 + 56.7 = 221.9 kN (18.0% of W) for the revised model with the axial-load factors. Neglecting the post-yield stiffness of the devices, this gives the upper bound of the strength ratio in Equation (11); the lower bound follows from the allowable displacement Da and is determined numerically (Section 5.10). The effective period of the isolation level is obtained from the effective stiffness at the maximum displacement (Equation (12)), where g is the gravitational acceleration.
The Ulcinj record of Section 3.4 was scaled in amplitude to 14 intensities from PGA = 0.05 g to 0.80 g (nominal PGA, the record digitized from the plot of [48] for 0.22 g multiplied by PGA/0.22 g) and applied to the base-fixed frame and to the isolation systems; the seven artificial records were scaled to the same 14 values of their absolute PGA (Section 5.13). The sensitivity of the reference system to the assumptions was checked at 0.30 g and 0.60 g (Section 5.11). The measures of the response are the isolation displacement and its residual value, the storey drifts, the storey shear (sum of the link forces), the roof acceleration, the ductility of the links, and the dissipated energy. The model is two-dimensional, so the analyses demonstrate the performance of the isolation system in one horizontal direction only (in the plane of the frame); the multidirectional behavior of the SF-ED device is a property established by the previous shaking-table tests [54,55,56,57,58] and is not verified by the present analyses.
5. Results
5.1. Influence of Span, Thickness and Strength on the Infill Response
The influence of the three parameters on the decoupled AAC infill is quantified in Table 14, computed from the calculation forms of Table 8 (Figure 9). The frame span mainly governs the deformation characteristics: when it increases from 4.0 to 6.0 m, the maximum force FM of the infill decreases by 19–50% and the corresponding displacement DM increases by 27–107%, so that the initial stiffness K0 decreases by 51–71%, which is consistent with the progressive loss of effectiveness of the diagonal compression mechanism as the span-to-height ratio increases. The dependence is not monotonic in all cases (for D = 400 mm, FM increases from 80 to 84 kN between 500 and 600 cm), which is the reason for the two span ranges of the forms. The infill thickness has the strongest effect on strength and stiffness: for L = 400 cm and G = 2.5 MPa, increasing D from 250 to 500 mm raises FM from 68 to 232 kN (a factor of 3.4; 3.7 at 500 cm and 4.3 at 600 cm) and K0 from 17 to 77 kN/mm, whereas DM changes little and with a sign that depends on the span (−25% at 400 cm, +20% at 500 cm and +13% at 600 cm). The AAC strength raises FM by 36–65% when it is increased from 2.5 to 5.0 MPa (D = 250 mm: +65% at 400 cm, +54% at 500 cm and +36% at 600 cm) and K0 by 40–61%, with changes in DM of at most about 10%. Only three levels of each parameter were analyzed, so that no optimum value can be inferred, and because DL = 2.5 DM by definition, the idealized ductility of the infill is constant and no conclusion on ductility can be drawn from the forms.
Table 14.
Change in the governing parameters of the decoupled AAC infill with the span, the thickness and the strength.
5.2. Consistency Check of the AACF Macro-Model Against the Experiment
The AACF macro-model of the single-storey frame was compared with the measured response of the tested frame and with that of the detailed micro-model (Figure 15, Table 15). Because the same specimen was used to define the parameters of the links, the comparison is a consistency check of the idealization and not an independent validation of the predictive capability of the model; independent test data have not yet been used (Section 6). With the original infill link (no softening), the peak force is 82.5 kN at 4 mm, against 80.0 kN measured at about 4.4 mm (+3.1%), and the force between 1 and 6 mm is within −3% to +7% of the experiment (the value at 1 mm, 51.5 kN, corrects the value of 43 kN read from the plot in the original submission). Beyond the peak, the strength decays only slowly, to 74.8 kN at 8 mm, whereas the measured response drops to 48.7 kN, so that the resistance is overestimated by 24% at 7 mm and by 54% at 8 mm. With the revised infill link (Section 3.3), the response up to the peak is unchanged, and the post-peak branch follows the experiment more closely (60.8 kN at 8 mm, +25%). Over the seven experimental points, the root-mean-square error is 11.8 kN (14.7% of the measured peak force) for the original and 5.4 kN (6.8%) for the revised link, against 3.7 kN (4.6%) for the micro-model; before the peak (1–4 mm), both AACF versions give 3.0 kN, and after the peak (6–8 mm), 17.6 and 7.5 kN. The micro-model curve in Figure 15 is the one plotted in [48] (peak 77.3 kN), whereas Figure 4 shows the micro-model curve of [42] (peak 82 kN); the experimental peak is 80.0 kN in both sources.
Figure 15.
Consistency check of the AACF macro-model of the single-storey frame: (a) monotonic force–displacement responses of the experiment (specimen M2 [42]), of the DIANA micro-model [48] and of the AACF model with the original infill link (no softening) and with the revised link (softening); (b) cyclic response of the AACF model, two cycles at amplitudes of 0.5–10 mm, with the original and with the revised (softening + degradation) infill link; (c) peak-to-peak stiffness normalized by its value at 0.5 mm (solid lines, left axis) and energy dissipated per cycle (dashed lines, right axis).
Table 15.
Consistency check of the AACF macro-model: force of the experiment, of the micro-model, and of the AACF model with the original and with the revised infill link at selected displacements, peak force, area under the force–displacement curve, and root-mean-square errors.
The cyclic response of the macro-model, computed for two cycles at each of the amplitudes 0.5, 1, 2, 3, 4, 6, 8 and 10 mm, is shown in Figure 15b,c. With the original link, the strength at a given amplitude is practically the same in the two cycles. With the revised link, the strength drops by 14% between the first and the second cycle after the peak (75.4 → 64.6 kN at 6 mm and 64.6 → 55.5 kN at 8 mm), the peak-to-peak stiffness at 10 mm decreases to 7% of its value at 0.5 mm, and the energy dissipated in the first cycle at 10 mm is 23% smaller (1052 against 1359 kN·mm). These quantities illustrate the adopted cyclic law. The cyclic response was also compared with the cyclic test M2-A [42,48] under the displacement history of the test (Appendix B, Table A2, Figure A1): the revised link reproduces the strength loss after the peak (28% and 23% from the peak cycle to the last cycle at about 9 mm, against 31% and 28% measured, and only 10% and 8% with the original link) and the decrease in the peak-to-peak stiffness (6.1 against 6.8 kN/mm at 9 mm), whereas the root-mean-square error of the cycle peak forces is 11 kN, partly because the measured response is asymmetric. The test was not used to calibrate the cyclic parameters, but it belongs to the same test program, so that this comparison is again a consistency check and not an independent validation.
5.3. Dynamic Characteristics of the Five-Storey Model
The dynamic characteristics of the five-storey model are given in Table 16 (mode shapes in Figure 16). The fundamental vibration period is T1 = 0.334 s with a modal mass participation ratio of 0.88, so that the first mode governs the global response; the first three modes together mobilize 99% of the mass. The period ratios T1/T2 = 2.9 and T1/T3 = 4.6 are close to the values of 3 and 5 of a uniform shear beam, which indicates a stiff, shear-type response. The fundamental period is about 59% of the period of 0.57 s given by the approximate expression of Eurocode 8 for RC moment-resisting frames of 15 m height [43], which reflects the considerable lateral stiffness added by the AAC infill. As cracking progresses in the masonry panels, the effective stiffness decreases and the periods lengthen; once the infill has degraded, the lateral resistance of the storey is provided by the RC columns alone. As shown in Figure 16, the first mode is a global lateral sway mode in which the displacement increases almost linearly with height up to the fourth floor; the second mode has a single sign change in the modal displacement at about two-thirds of the building height, and the third mode, a higher-order lateral mode, has two sign changes.
Table 16.
Periods, frequencies and modal mass participation of the five-storey AAC-infilled RC frame.
Figure 16.
Mode shapes of the first three vibration modes of the five-storey AACF model, normalized to the maximum modal displacement; T is the period, and UX is the modal mass participation ratio.
5.4. Nonlinear Time-History Response of the Five-Storey Frame
Nonlinear time-history analyses were performed for the two earthquake intensity levels, PGA = 0.22 g and 0.30 g. Figure 17 shows the displacement, velocity, and acceleration histories of the first and fifth storeys (re-plotted from the response plots of the analyses [48]), and Table 17 lists their largest positive and negative values, taken from the analysis output.
Figure 17.
Time histories of the response of the five-storey AACF model at storeys 1 and 5 under the Ulcinj–Albatros record scaled to PGA = 0.22 g (a,c,e) and 0.30 g (b,d,f): (a,b) displacement, (c,d) velocity, (e,f) acceleration. The circles mark the largest positive and negative values (as given in the analysis output). Re-plotted from the response plots of [48].
Table 17.
Largest positive and negative values of the displacement, velocity and acceleration of the first and of the fifth storey of the five-storey frame at the two intensity levels.
At the lower intensity, the maximum lateral displacement reached 1.98 cm at the first storey and 3.70 cm at the roof, and the peak roof acceleration was 4.49 m/s2, i.e., 2.08 times the nominal PGA of 0.22 g. At PGA = 0.30 g, the corresponding values are 3.72 cm, 5.86 cm, and 6.38 m/s2 (2.17 times the PGA), and the peak roof velocity increases from 0.38 to 0.50 m/s. The dynamic amplification factor, defined as the largest absolute roof acceleration divided by the nominal PGA, is therefore practically the same at the two intensities and does not decrease with the increasing nonlinearity of the response. The displacement histories are strongly asymmetric: the largest displacements occur in the negative direction at about 8 s, near the strongest part of the record, and exceed the largest positive displacements by 37% at the first storey at PGA = 0.22 g (1.98 against 1.45 cm) and by 111% at PGA = 0.30 g (3.72 against 1.76 cm). While at 0.22 g the displacements return to practically zero at the end of the record, at 0.30 g the first storey retains a residual displacement of about 1.4 cm (0.5% of the storey height) and the roof of about 1.9 cm (values read from the plots), a further sign of the accumulation of the deformation in the first storey, which contributes 54% of the roof displacement at 0.22 g and 63% at 0.30 g (negative peaks).
5.5. Hysteretic Response of the Links
The hysteresis loops of the nonlinear links are the most direct indicator of the nonlinear behavior of the AACF model: they show how much each storey deforms, how the stiffness degrades, and how much force the RC columns and the AAC infill carry. Figure 18a shows the backbone of the RC column link of the first storey: an elastic branch with the stiffness K0 = FY/DY = 20 kN/mm up to the yield point Y (DY = 3.6 mm, FY = 72 kN), a second branch up to the point U of maximum strength (DU = 20.2 mm, FU = 110 kN) and a nearly horizontal branch up to the last point L (DL = 39.6 mm, FL = 112 kN), the same in the negative direction. The horizontal axis of all loops is the deformation of the link (the relative displacement of its end nodes, which for the links of the first storey equals the storey displacement) and the vertical axis is the force of one link; the storey shear is the sum of the forces of the two RC column links and of the infill link.
Figure 18.
How to read the hysteresis loops of the nonlinear links: (a) backbone (envelope) of the RC column link of storey 1 with the points Y, U, and L and the initial stiffness K0; (b) loop of the Takeda model (schematic, not to scale) with the numbered loading, unloading and reloading rules listed below the panels; (c,d) computed loops of the RC column link L1 and of the AAC infill link L32 of storey 1 for PGA = 0.22 g, with the backbone (dashed) and the largest positive and negative response points (circles).
The loops of the RC column links follow the rules of the Takeda model [60] (Figure 18b). The first loading follows the backbone (rule 1). On reversal, the link unloads with a stiffness that is smaller than K0 and decreases with the largest deformation reached (rule 2), reloads towards the yield point of the opposite side (rule 3), and continues on the backbone up to the largest deformation reached on that side (rule 4). A further reversal again produces unloading with degraded stiffness (rule 5), after which the link reloads towards the previous peak of the opposite side (rule 6); loading beyond that peak returns to the backbone (rule 7), and the following unloading is even softer because the peak is larger (rule 8). The area enclosed by a loop is the energy dissipated in the cycle, and the deformation at which the loop crosses the axis F = 0 is the residual deformation. The SAP2000 analyses of [48] do not report the parameters of the Takeda model (exponent of the unloading stiffness, reloading rule) or the hysteresis type of the infill link; the loops shown are those computed there.
Figure 18c,d show the computed loops of the RC column link L1 and of the AAC infill link L32 of the first storey at PGA = 0.22 g; the loops of all twenty links, for both intensities, are shown in Figure 19 and Figure 20 (computed in SAP2000 [48] and digitized from the published plots). Four simple rules suffice to interpret them: (i) a loop on the straight line of slope K0 is elastic, and any enclosed area or residual deformation shows yielding; (ii) the ratio |D|max/DY of the largest deformation to the yield deformation, given in every panel, is the displacement ductility demand of the link; (iii) the ratio of the largest deformation to the deformation limit Df shows whether the damage limit adopted for the link is exceeded; (iv) the largest forces are limited by the backbone, so that a flat top of the loops indicates that the strength of the link is exhausted.
Figure 19.
Hysteresis loops of the RC column links (upper row) and of the AAC infill links (lower row) in storeys 1–5 for PGA = 0.22 g, computed in SAP2000 [48] and digitized from the published plots, so that small inner cycles are approximate (blue: loops; dashed gray: backbone of the link; circles: largest positive and negative response; dotted red lines: deformation limit Df = 30 mm for RC columns and 15 mm for AAC infill, where inside the plotted range). The label in each panel is the largest deformation divided by the yield deformation DY of the link (3.6 mm for the RC column links, 4.0 mm for the infill links). The deformation scale differs from panel to panel; the force scale is common to each row. The identifiers of the SAP2000 links are given in brackets. Re-plotted from the digitized curves of [48].
Figure 20.
Hysteresis loops of the RC column links (upper row) and of the AAC infill links (lower row) in storeys 1–5 for PGA = 0.30 g (SAP2000 [48], digitized from the published plots); blue: loops; dashed gray: backbone of the link; circles: largest positive and negative response; dotted red lines: deformation limits, as in Figure 19; the deformation scale differs from panel to panel, the force scale is common to each row.
At PGA = 0.22 g, the response is concentrated in the two lowest storeys. In the first storey, the RC column link L1 reaches deformations of +14.6 and −19.9 mm, i.e., 5.5 times the yield deformation, and forces of +97.2 and −109.4 kN, close to the maximum strength FU = 110 kN. The infill link L32 of the same storey is subjected to the same deformations (the limit Df = 15 mm is exceeded in the negative direction), and its force remains at 84.5 and 85.0 kN, i.e., on the force plateau after the point U. The loops of the second storey are narrower (+7.4 and −11.1 mm, ductility 3.1 for the column link and 2.8 for the infill link), and the deformation limits are not exceeded. In the third storey, the column link only just exceeds its yield deformation (ductility 1.1), and the infill link is at the yield point, and in the fourth and fifth storeys the links remain elastic: the loops degenerate to straight lines with the slope K0 (the largest forces of the column links in these storeys, 59.6 and 30.2 kN, correspond to deformations of 2.8 and 1.5 mm). The forces of the second-storey links are +79.6 and −87.0 kN in the column link and +81.0 and −84.3 kN in the infill link; the third-storey infill link reaches its yield force of 63 kN at the deformation of −4.1 mm.
At PGA = 0.30 g, the deformation of the first storey increases considerably, from 19.9 to 37.2 mm in the negative direction (+87%) and from 14.6 to 17.6 mm in the positive direction, which is 10.3 times the yield deformation of the column link and exceeds the limits of both the infill (Df = 15 mm) and the RC columns (Df = 30 mm). However, the force of the column link increases only from 109.4 to 111.8 kN, because the backbone is nearly horizontal beyond point U, so that the greater demand is absorbed almost entirely by deformation and the loops become flat on top. The loops of the second storey also grow (+8.2 and −14.1 mm, ductility 3.9, approaching the limit of the infill), the third storey is slightly beyond yielding (ductility 1.5), and the upper storeys remain elastic. The increase in intensity by 36% is thus absorbed mainly by the first storey, which is characteristic of a soft-storey mechanism.
Table 18 and Figure 21 summarize the extreme deformations and forces of all links, the ductility demand, the ratio Kpp/K0 of the peak-to-peak secant stiffness of the largest loop to the initial stiffness (equal to 1.0 for an elastic link), and the share of the infill link in the storey shear at the instants of the largest positive and negative deformation. Kpp/K0 of the column links is about 1.0 in storeys 4 and 5 and decreases to 0.30 in the first storey at PGA = 0.22 g and to 0.20 at PGA = 0.30 g, which quantifies the degradation of the stiffness of the first storey.
Table 18.
Extreme responses of the nonlinear links of the five-storey frame.
Figure 21.
Summary of the extreme responses of the links under the two intensities: (a) largest link deformation of each storey (the same for the RC column link and for the AAC infill link of a storey), with the yield deformation DY of the RC column link; (b) largest link forces; (c) maximum storey shear, obtained as the sum of the forces of the two RC column links and of the infill link at the instant of the largest deformation (derived quantity).
The deformation demand decreases rapidly with the height (Figure 21a): the largest deformation is 19.9, 11.1, 4.1, 2.8 and 1.7 mm in storeys 1 to 5 at PGA = 0.22 g and 37.2, 14.1, 5.5, 3.0 and 1.9 mm at PGA = 0.30 g, so that the increase in the intensity by 36% increases the deformation of the first storey by 87%, but that of the fifth storey by only 12%. In contrast, the largest forces (Figure 21b) are limited by the strengths of the links and depend only weakly on the intensity (+2% for both the column link and the infill link of the first storey). The maximum storey shear (Figure 21c) decreases from about 304 kN in the first storey to about 94 kN in the fifth storey at PGA = 0.22 g, and at PGA = 0.30 g from about 310 kN to about 105 kN; the maximum shear of the first storey at PGA = 0.30 g corresponds to 28% of the weight of the building of 1120 kN. In all storeys, the infill carries 27–34% of the storey shear, which is close to its 28% share of the initial stiffness; the AAC infill is therefore a major part of the lateral resistance of the building at both intensities, and its loss, which in the adopted idealization is not modeled beyond the deformation limit, would transfer the entire shear to the RC columns.
The capability of the AACF macro-model to reproduce the cumulative nonlinear storey response was evaluated by comparing the hysteretic response of the first storey (RC columns and AAC infill together) obtained from the time-history analysis with the cumulative envelope constructed from the positive and negative pushover analyses (Figure 22). The hysteretic response follows the pushover envelope, which means that the first-storey force–displacement behavior under cyclic seismic loading is consistent with the envelope used to define the links; this is the expected behavior of the adopted link formulation and a consistency check of the model rather than an independent validation. The cumulative first-storey force reached 279.0 kN at +14.6 mm and −303.8 kN at −19.9 mm; the latter corresponds to about 27% of the total weight of 1120 kN.
Figure 22.
Cumulative first-storey response (RC columns and AAC infill) under the earthquake excitation (PGA = 0.22 g) compared with the cumulative envelope obtained from the positive and negative pushover analyses (visible part).
5.6. Storey Displacements, Drifts and Damage Limits
The maximum storey displacements are presented in Figure 23a. At PGA = 0.22 g, the maximum displacement is 1.98 cm at the first storey and 3.70 cm at the roof, while the remaining storeys experience relatively small inter-storey deformations; at PGA = 0.30 g the first-storey displacement increases to 3.72 cm and the roof displacement to 5.86 cm. The inter-storey drift ratios (Figure 23b) make the concentration of the deformation in the first storey evident: the first-storey drift is 0.66% at PGA = 0.22 g and 1.24% at PGA = 0.30 g, whereas the mean drift of storeys 2–5 is only 0.14% and 0.18%, so that the first-storey drift is about 5 and 7 times the mean drift of the upper storeys (Table 19). An increase in the PGA by 36% increased the first-storey displacement by 88% but the roof displacement by only 58%. This behavior is typical of the soft-storey mechanisms observed after earthquakes in infilled RC buildings [4,5] and indicates the development of a soft-storey mechanism initiated by the progressive degradation of the first-storey AAC infill and of the RC columns.
Figure 23.
Maximum storey displacements of the five-storey frame at PGA = 0.22 g and 0.30 g: (a) displacement profiles in the positive and negative directions (the lines connect the values reported for the first and the fifth storey); (b) inter-storey drift ratio of the first storey and mean drift ratio of storeys 2–5.
Table 19.
Summary of the nonlinear time-history response of the five-storey frame at the two intensity levels.
Considering the deformation limits adopted for the nonlinear links (Df = 3.0 cm for the RC columns and Df = 1.5 cm for the AAC infill), derived from the parametric study and consistent with the performance criteria of Eurocode 8 and FEMA 356 [43,46], the first-storey displacement of 1.98 cm at PGA = 0.22 g exceeded the limit of the AAC infill by 32% but remained within that of the RC columns (66% of the limit); the infill of the second storey, with 1.11 cm (74% of its limit), also remained within it, so that the damage was mainly confined to the first-storey AAC infill, whereas the upper storeys remained close to the elastic range. At PGA = 0.30 g the first-storey displacement of 3.72 cm exceeded the deformation capacity of the RC column links by 24% and the limit of the AAC infill by a factor of 2.5, which in the adopted idealization corresponds to the loss of the load-carrying capacity of the first-storey infill and indicates the initiation of a soft-storey mechanism; the infill of the second storey, with 1.41 cm (94% of its limit), approached its limit, while the upper storeys remained largely elastic. Overall, the AACF macro-model made it possible to carry out nonlinear time-history analyses of the five-storey frame at a modest computational cost and to identify the first storey as the critical one; an independent validation of the multi-storey response against experimental or detailed numerical results remains to be done (Section 6).
5.7. Verification of the OpenSees Model Against the SAP2000 Analyses
The OpenSees model of the base-fixed frame was verified against the SAP2000 time-history analyses of [48] (Figure 24, Table 20) by comparing the first 15 s of the responses, the length of the plots in [48]. The displacement histories of the first storey and of the roof agree closely (correlation coefficients 0.94–0.97), and their largest absolute values are within 0.1–6.5% of the SAP2000 values; the largest first-storey drifts are 0.68% and 1.32% against 0.66% and 1.24%. The roof accelerations are reproduced less well: the correlation coefficients are only 0.52–0.60 and the largest absolute values differ by +10% and −13%, because the acceleration is dominated by the higher modes and by details of the damping and of the hysteresis rules that are not reported in [48]. The verification is therefore one of displacements and drifts; the accelerations of the OpenSees model are used for comparisons between systems analyzed with the same model, not as absolute values. The fundamental period of the OpenSees model, 0.447 s, is that of the shear building defined by the initial slopes of the link backbones (2 × 20 + 15.75 = 55.75 kN/mm per storey) and differs from the value of 0.334 s reported for the SAP2000 model (Table 16). The mass is the same in both models (22.8 t per storey); for a uniform shear building, the period ratio of 1.34 corresponds to a storey stiffness of about 100 kN/mm in SAP2000, which is practically the secant stiffness of the uncracked tested frame (52.9 kN at 1 mm, i.e., about 106 kN/mm in the prototype). The SAP2000 modal analysis therefore used the linear (uncracked) stiffness assigned to the link elements, whereas the nonlinear analyses in both programs follow the backbones; the OpenSees period is the one consistent with the nonlinear response, and the agreement of the displacement histories, in which the yielded stiffness of the links governs, confirms that the elastic period does not govern the response studied here. Because the damping ratio (8%) and the Takeda exponent of the original OpenSees model were calibrated to reproduce the SAP2000 displacements, the revised model uses a damping ratio of 5% and adds P–Δ effects, the softening and degradation of the infill, and the axial-load correction of the columns; the influence of each of these assumptions is quantified in Section 5.12, and the accelerations are given for damping ratios of 2–5% in Section 5.11.
Figure 24.
Verification of the OpenSees model of the base-fixed frame against the SAP2000 analyses [48] (time-history responses re-plotted from [48]): (a,d) first-storey displacement, (b,e) roof displacement, (c,f) roof acceleration, for PGA = 0.22 g (a–c) and 0.30 g (d–f); r is the correlation coefficient of the two histories over the first 15 s.
Table 20.
Comparison of the largest absolute responses of the base-fixed five-storey frame in the SAP2000 analyses [48] and in the OpenSees model (first 15 s of the record).
5.8. Response of the Base-Isolated Frame
Figure 25 and Table 21 compare the base-fixed frame with the isolated frame (revised model, 5% damping, Ulcinj record). At PGA = 0.30 g, the base-fixed frame has a first-storey drift of 1.60%, a first-storey shear of 250 kN, and 67 kN·m dissipated by its links, i.e., by damage; the deformation is concentrated in the first storey (drifts of the upper storeys ≤ 0.26%, Figure 25e). With the reference isolation system (bearings + one SF-ED device), the first-storey drift is 0.10% (−94%), the shear is 173 kN (−31%), and the peak absolute roof acceleration is 2.72 m/s2 (−40%); the drifts of all storeys are between 0.04% and 0.11% (Figure 25e) and the soft-storey mechanism disappears. The isolation level dissipates 59 kN·m (Figure 25a,f), 66% of it in the SF-ED device; its displacement is 91 mm and its effective period is 1.57 s (Equation (12)), against 0.435 s for the base-fixed frame. At PGA = 0.60 g, for which the base-fixed frame has a first-storey drift of 2.80%, the isolated frame has a first-storey drift of 0.12% (largest storey drift 0.14%, in the second storey), a shear of 208 kN (against 256 kN), a roof acceleration of 4.66 m/s2 (against 6.67 m/s2) and an isolation displacement of 143 mm, and its superstructure dissipates 1.5 kN·m, against 155 kN·m in the base-fixed frame.
Figure 25.
Response of the base-isolated frame (revised model, 5% damping; reference system: bearings + one SF-ED device, ψ = 11.7%): (a) force–displacement loops of the isolation level at PGA = 0.30 g and 0.60 g (dotted lines: allowable displacement); (b) displacement histories of the isolation level, including the system with the bearings only at 0.60 g; (c) first-storey shear against first-storey deformation of the base-fixed and of the isolated frame at 0.30 g (dotted lines: yield shear of 221.9 kN); (d) roof-acceleration histories at 0.30 g; (e) maximum inter-storey drift of each storey for the base-fixed and the isolated frame at 0.30 g, the isolated frame at 0.60 g and the system with two devices at 0.30 g (dotted lines: drift indicators of 0.13%, 0.5% and 1.0%); (f) energy dissipated by the links of the base-fixed frame and by the elements of the isolated system.
Table 21.
Response of the base-fixed and base-isolated five-storey frame at three intensities of the Ulcinj record (maximum values, revised model).
The SF-ED device has two effects. First, it limits the isolation displacement: the bearings alone reach 112 mm at 0.30 g and 248 mm at 0.60 g, which exceeds their displacement capacity of 200 mm, whereas with one device the displacements are 91 mm (−19%) and 143 mm (−42%). The bearings alone give the lowest shear (39 and 62 kN) and roof acceleration (0.87 and 1.41 m/s2). Second, the device gives the isolation level the strength that dissipates the energy, but this strength is transmitted to the superstructure: the shear rises from 39 kN (bearings only) to 173 kN at 0.30 g and to 208 kN at 0.60 g, close to the yield shear of the first storey (221.9 kN). With two devices, the isolation displacement is only 26 mm at 0.30 g, but the transmitted shear (252 kN) is that of the base-fixed frame, the first-storey drift is 1.45%, and the links dissipate 54 kN·m; the isolation level is too strong for the superstructure. With ψ = 6%, the shear is 105 and 121 kN, and the roof acceleration is 1.73 and 2.62 m/s2 at 0.30 and 0.60 g, with isolation displacements of 79 and 138 mm. The main drawback of the system is the residual displacement of the isolation level, 14 mm at 0.30 g and 25 mm at 0.60 g with one device and up to 48 mm with ψ = 6%: the restoring force of the bearings, i.e., the increase in their force beyond the yield point, is only 2.8% of the weight at the displacement of 200 mm, of the same order as their friction force (1.5%), so that the isolation level does not re-center completely; the residual displacement has to be removed after the earthquake or limited by the geometry of the bearings or by a re-centering element. The residual displacements depend on the sequence of the cycles and are indicative values.
5.9. Response as a Function of the Intensity and Delimitation of the Two Approaches
For the Ulcinj record the revised base-fixed frame reaches the yield of the infill (0.13% drift) at a nominal PGA of 0.056 g, the drift of 0.5% at 0.156 g and the drift of 1.0% at 0.191 g (Figure 26a, Table 22), i.e., at absolute PGAs of 0.061, 0.170 and 0.208 g; the original model gave 0.06, 0.19 and 0.26 g. Its first-storey shear exceeds the yield shear of 221.9 kN from 0.08 g and saturates at 250–263 kN from 0.10 g (Figure 26b). The infill thus cracks at a very low intensity, and the damage becomes severe at a moderate one. These values delimit the first approach for the frame, and the record studied: the design approach of Section 4.2 is adequate up to about 0.16 g (repairable damage of the infill) and, as a limit, 0.19 g (columns). The softening of the infill and the P–Δ effect lower the latter two thresholds by 17–26% compared with the original model (Section 5.12), whereas the seven spectrum-compatible records give considerably higher thresholds (Section 5.13); the values are therefore specific to the example structure and input and are not general limits.
Figure 26.
Response as a function of the intensity (nominal PGA of the Ulcinj record; revised model) for the base-fixed frame and the isolation systems: (a) first-storey drift (logarithmic axis; dotted lines: drift indicators); (b) first-storey shear (dotted line: yield shear of 221.9 kN); (c) roof acceleration; (d) isolation displacement (dotted line: Da = 160 mm); (e,f) isolation displacement and first-storey shear against the strength ratio ψ of the SF-ED devices at five intensities.
Table 22.
Intensity (nominal PGA of the Ulcinj record, in g) at which each limit is reached by the base-fixed frame (original and revised model) and by the isolated systems (revised model; interpolated between the analyzed intensities).
The frame isolated by the bearings and one SF-ED device keeps the first-storey drift between 0.05% and 0.135% for all intensities up to 0.80 g (0.13% is reached only at 0.73 g), but the drift of the second storey reaches the yield drift of the infill from 0.54 g (0.18% at 0.80 g); the first-storey shear remains between 77 and 213 kN, below the yield shear of 221.9 kN. The isolation displacement increases with the intensity up to 183 mm at 0.80 g and exceeds the allowable displacement of 160 mm from 0.67 g (Figure 26d), whereas the bearings alone exceed it from 0.40 g and their capacity of 200 mm from 0.49 g. With ψ = 6%, all storey drifts remain below 0.09%, the shear is below 132 kN, and the displacement exceeds 160 mm at 0.72 g. The roof acceleration is lower in the isolated frame than in the base-fixed frame at all intensities (Figure 26c): the reduction is 20–52% with one device and 55–71% with ψ = 6% for PGA of 0.10–0.80 g, whereas with two devices it is only 0–30%, and the first-storey drift reaches 0.13% at 0.06 g, 0.5% at 0.12 g and 1.0% at 0.19 g, i.e., no later than in the base-fixed frame, so that two devices cannot be regarded as a protection of the infill. For the Ulcinj record, the range of application of the second approach is thus limited by the displacement of the isolation layer, at about 0.67–0.72 g, and, for the reference system, by the onset of infill cracking in the upper storeys from about 0.54 g (0.42 g with 2% damping, Section 5.11).
5.10. Strength of the SF-ED Devices and Admissible Range
The strength of the SF-ED devices is the main design parameter (Figure 26e,f, Table 23). The first-storey shear increases almost linearly with ψ (at 0.30 g from 39 kN without devices to 173 kN with ψ = 11.7% and 252 kN with ψ = 23.4%). The isolation displacement, in contrast, decreases only at small values of ψ and is not monotonic: at 0.30 g it falls from 112 mm without devices to 75 mm with ψ = 1%, fluctuates between 73 and 96 mm for ψ between 1% and 14% and decreases again, to 26 mm, only with ψ = 23.4%; at 0.60 g it falls from 248 mm to 149 mm with ψ = 3% and is then practically constant (137–147 mm for ψ between 4% and 17.5%). A plausible reason is that the larger stiffness of the isolation level shortens the effective period (from 3.8 s without devices to 0.65 s with ψ = 23.4% at 0.30 g) and increases the spectral demand, which offsets the energy dissipated by the devices; this explanation was not verified separately. The admissible range of ψ is therefore bounded from below by the allowable displacement of 160 mm and from above by the yield shear of the first storey (Equation (11)); Table 23 gives the range at five intensities.
Table 23.
Admissible range of the strength ratio ψ of the SF-ED devices (Diso ≤ 160 mm and storey-1 shear ≤ Vy,1 = 221.9 kN) and response with ψ = 6% and ψ = 11.7% (one device); revised model, Ulcinj record.
Up to 0.70 g a range of ψ exists, from 0.0 to 15.7% at 0.30 g to 5.3–8.8% at 0.70 g; up to 0.60 g the upper bound is set by the yield shear and agrees with the estimate of Equation (11) (ψ ≲ 13.7%), at 0.70 g it is set by the displacement, which increases again for ψ above about 10%, and the lower bound increases with the intensity. At 0.80 g no value of ψ meets both conditions, so that the isolation layer should be designed for a larger displacement, or complemented with displacement-limiting buffers [58,59]. Within the range, for the Ulcinj record, a value of ψ of about 6% is more favorable than the reference of 11.7%: at 0.60 g it gives a displacement of 138 mm instead of 143 mm, a shear of 121 kN instead of 208 kN (−42%) and a roof acceleration of 2.62 m/s2 instead of 4.66 m/s2 (−44%). However, under the seven spectrum-compatible records, ψ = 6% gives larger isolation displacements than ψ = 11.7% (Section 5.13), so that the favorable value depends on the input; a range of about 6–12% is indicated, with the lower values when the displacement capacity of the isolation level is large. The reference system of one device is admissible up to 0.67 g but is close to the upper bound, so that the superstructure is near its elastic limit at the largest intensities. These findings are obtained for the assumed devices and indicate the ranges in which the devices should be designed rather than an optimum.
5.11. Sensitivity to the Assumptions
The reference system was checked with devices at the tested size (λ = 1), base-slab masses of 0.25 and 1.0 of a storey mass, friction of the bearings × 0.7 and × 1.3, damping of the superstructure of 5% and 10%, the stiffness and hardening of the 8C device [58] (yield displacement 20 mm, at the same total yield force) and, to quantify the effect of the damping model, damping of the complete model (Table 24). For the seven variations in the assumptions other than the size of the devices and the damping model, the isolation displacement ranged from 82 to 90 mm at 0.30 g and from 137 to 149 mm at 0.60 g (−4% to +6% and −3% to +5% of the reference), the first-storey drift from 0.10 to 0.13% and the first-storey shear from 163 to 207 kN, i.e., up to and slightly above the corrected yield shear of the original model (200.7 kN; 203–207 kN with the larger base-slab mass, the larger friction, and the stiffness of the 8C device at 0.60 g). The friction of the bearings governs the residual displacement at 0.30 g (10 mm with the friction × 0.7 and 25 mm with × 1.3, against 16 mm for the reference), but not at 0.60 g (27–28 mm in all three cases); the residual displacements of all variations range from 6 to 31 mm. Two assumptions change the results substantially. Devices at the tested size, with the same ψ, are stiffer and yield at a displacement four times smaller: the isolation displacement decreases to 47 mm and 97 mm, but the roof acceleration increases to 4.81 and 6.62 m/s2 (+91% and +86%), and the shear at 0.60 g increases to 240 kN, so that the superstructure yields (ductility 2.0); the size of the devices, not only their total strength, must therefore be designed. Damping applied to the complete model, as is common in frame analyses, reduces the isolation displacement by −39% and −15% at the two intensities, but increases the roof acceleration by 47% and 42%, because the damping forces of the isolation mode are transmitted to the superstructure; it is not appropriate for an isolated structure and was not used. The rows of the revised model show that the isolation displacement is practically independent of the damping of the superstructure (140–143 mm at 0.60 g for 2–5%), whereas the roof acceleration increases by up to 12% (0.30 g) and 14% (0.60 g) when the damping is reduced from 5% to 2%, and the largest storey drift of the reference system at 0.60 g increases from 0.14% to 0.20%, so that the upper storeys reach the yield drift of the infill (0.13%) from 0.54 g with 5%, 0.46 g with 3% and 0.42 g with 2% damping. With ψ = 6%, the storey drifts remain below 0.11% up to 0.80 g, also with 2% damping.
Table 24.
Sensitivity of the response of the isolated frame to the assumptions, at PGA = 0.30 g and 0.60 g: original model (8% damping; reference system, one SF-ED device) and revised model with damping ratios of 2–5%.
5.12. Effect of the Model Refinements and Sensitivity to the Infill Envelope
To quantify the influence of the simplifications of the original model, the base-fixed frame was analyzed with the refinements of the revised model added one at a time (Table 25, Figure 27a): S0, the original model; S1, with P–Δ effects; S2, with the softening envelope of the infill; S3, with its cyclic degradation (Pinching4); S4, with the axial-load correction of the columns; and S5, with 5% instead of 8% damping, which is the revised model. S0 reproduces the original OpenSees results (Table 20, Table 21 and Table 22). The P–Δ effect alone lowers the PGA at the drifts of 0.5% and 1.0% by 3% and increases the first-storey drift at 0.30 g from 1.33% to 1.41%. The softening of the infill has the largest effect: it lowers the PGA at 1.0% drift from 0.250 to 0.212 g, increases the first-storey drift at 0.60 g from 2.09% to 2.37% and reduces the first-storey shear at 0.30 g from 311 to 248 kN, because the infill loses its strength beyond 8 mm instead of keeping 84–86 kN. The cyclic degradation and the reduction in the damping further increase the drifts, whereas the larger strength of the axial-load-corrected columns decreases them (thresholds +3–7%). Overall, the revised model reaches the drifts of 0.5% and 1.0% at 0.156 and 0.191 g, i.e., 17% and 26% earlier than the original model, and its first-storey drift is 1.60% at 0.30 g and 2.80% at 0.60 g (3.8% at 0.80 g, with drifts of the upper storeys ≤ 0.36%): the omission of the softening made the original assessment of the base-fixed frame unconservative at high intensities, and the soft-storey mechanism develops earlier. The yield of the infill (0.13%) is reached at 0.05–0.07 g in all versions.
Table 25.
Effect of the model refinements (S0–S5) and of the assumptions of the infill envelope on the response of the base-fixed five-storey frame (Ulcinj record, nominal PGA).
Figure 27.
Effect of the model refinements on the base-fixed frame: (a) first-storey drift against the nominal PGA of the Ulcinj record for the steps S0–S5 of Table 25 (dotted lines: drift indicators of Section 3.4); (b) PGA at which the first-storey drift reaches 0.13%, 0.5% and 1.0% for the revised model and for the variations in the infill envelope.
The sensitivity of the revised model to the assumptions of the infill envelope is also given in Table 25 and Figure 27b. The ratio DL/DM (2.0 or 3.0 instead of 2.5), the residual strength (0% or 20% instead of 10% of FM), the maximum force (68 kN of Form 1 instead of 84 kN, −19%, Section 3.2) and the initial stiffness (21 kN/mm, the tangent of the parabola, instead of the secant of 15.75 kN/mm, Section 3.3; first period 0.427 instead of 0.435 s) change the PGA at which the three drift limits are reached by at most 0.003 g, and the omission of the cyclic degradation by at most 0.011 g. The first-storey drift at 0.30 g varies between 1.43% and 1.69%. The thresholds are therefore robust with respect to the uncertainty of the decoupled infill parameters, because beyond the infill yield the response is governed by the columns and by the softened infill; the isolated systems, whose infill remains near its elastic range, are even less sensitive.
5.13. Record-to-Record Variability
The revised base-fixed frame, the reference isolation system (ψ = 11.7%) and the system with ψ = 6% were analyzed with the seven spectrum-compatible records of Section 3.4 at the 14 intensities (294 analyses; Table 26, Figure 28). For the base-fixed frame the drifts of 0.13%, 0.5% and 1.0% are reached at 0.091 ± 0.013, 0.237 ± 0.018 and 0.382 ± 0.040 g (mean ± standard deviation), whereas the Ulcinj record gives 0.061, 0.170 and 0.208 g in terms of the absolute PGA (Figure 28b): for the analyzed frame, whose first period of 0.435 s lies on the plateau of the EC8 spectrum, the Ulcinj record is considerably more damaging than the broadband spectrum-compatible records, and the first-storey drift at 0.30 g is 0.77 ± 0.08% against 1.60% (Ulcinj, nominal 0.30 g). At 0.60 g, the difference becomes small (2.53 ± 0.51% against 2.80%). The PGA thresholds of Section 5.9 and Section 5.12 are therefore specific to the example structure and the adopted input and must not be interpreted as general limits for AAC-infilled RC buildings.
Table 26.
Response of the revised model to the Ulcinj–Albatros record and to the seven spectrum-compatible records of EN 1998-1: mean ± standard deviation, with the range of the seven records in brackets.
Figure 28.
Record-to-record variability: (a) pseudo-acceleration spectra (5% damping) of the seven artificial records normalized by their PGA, their mean, the EN 1998-1 target (Type 1, ground type B) and 90% of the target (shaded: period ranges of the base-fixed and of the isolated frame); (b) first-storey drift of the revised base-fixed frame against the absolute PGA for the seven records (gray), their median and the Ulcinj record; (c) isolation displacement of the reference system (ψ = 11.7%) and of the system with ψ = 6% for the seven records (thin lines), their medians and the Ulcinj record (dashed).
With isolation, the superstructure remains practically elastic for all records: with the reference system the first-storey drift does not exceed 0.124%, and the largest storey drift 0.16%, the yield drift of the infill being exceeded in an upper storey only for two of the seven records (at 0.63 and 0.79 g); with ψ = 6% all storey drifts remain below 0.09%. The isolation displacement depends on the record (Figure 28c): with the reference system it is 74 ± 22 mm at 0.30 g and 141 ± 26 mm at 0.60 g and exceeds 160 mm at 0.62 ± 0.09 g for five records (not up to 0.80 g for the other two), whereas with ψ = 6% it is 82 ± 19 and 183 ± 32 mm and exceeds 160 mm at 0.55 ± 0.09 g for all records. Under these broadband records, the smaller device strength thus gives a smaller transmitted shear (104 ± 4 against 174 ± 4 kN at 0.30 g) and roof acceleration (1.55 against 2.90 m/s2) but a larger isolation displacement, contrary to the Ulcinj record, for which both systems had similar displacements. The choice of ψ is therefore a compromise that depends on the input and on the displacement capacity of the isolation level, and the results support a range of about 6–12% rather than a single optimum.
6. Discussion
The proposed method bridges detailed nonlinear finite element modeling and practical engineering analysis of AAC-infilled RC frames. The nonlinear behavior of the infill is represented by two governing parameters, FM and DM, obtained by subtracting the response of the bare frame from that of the infilled frame (uniform decoupling), which defines the apparent contribution of the infill, including its interaction with the frame, with an uncertainty of about ±4 kN in the scaled models (Section 3.2). In practical terms, the procedure requires only the span, the thickness and the strength of the infill: the characteristic points of the infill link follow from Equations (2)–(7) and Table 8 (procedure of Table 11) by hand calculation, and the link is added to a conventional frame model together with Takeda column links, which replaces a detailed finite element analysis of each infilled frame. Compared with equivalent-strut models, whose width and strength are obtained from empirical formulae developed mainly for clay-brick or concrete-block masonry [8,9,10,11,12,13,14], the AACF link is calibrated on validated models of AAC infills; an indicative comparison with the strut of ASCE/SEI 41 shows that generic formulas would overestimate the stiffness and the strength of the AAC infill considerably (Section 3.3), whereas a systematic comparison with strut models remains to be made. The macro-model is consistent with the tested frame (peak resistance +3.1%, root-mean-square error 6.8% of the peak with the revised infill link, Section 5.2), but this is a consistency check on the specimen that defined its parameters, not an independent validation.
Among the investigated parameters, the frame span was found to govern the deformation characteristics of the AAC infill, whereas the infill thickness had the strongest effect on its strength and stiffness. Increasing the span progressively reduced the initial lateral stiffness and maximum lateral resistance while increasing the deformation demand. This behavior reflects the gradual reduction in the effectiveness of the diagonal compression mechanism as the span-to-height ratio increases, resulting in a more pronounced contribution of the reinforced concrete frame to the overall structural response. In contrast, increasing the AAC infill thickness primarily enhanced the lateral stiffness and load-carrying capacity, whereas its influence on deformation capacity remained comparatively limited. A similar tendency was observed for the compressive strength of AAC masonry. Higher compressive strength increased the maximum restoring force and initial stiffness; however, its influence on the overall deformation characteristics of the structural system was less significant than that of the frame geometry. Overall, the results indicate that the frame span governs the deformation characteristics of AAC-infilled RC frames, whereas the infill thickness and, to a lesser extent, its compressive strength mainly control their stiffness and lateral resistance.
The hysteresis loops (Section 5.5) show that the inelastic response of the five-storey frame is concentrated in the lowest storeys: the increase in the intensity by 36% (from 0.22 g to 0.30 g) increased the deformation of the first storey by 87% but the force of its column link by only 2%, because the strength of the link was exhausted, and the infill carried 27–34% of the storey shear, a share close to its 28% share of the initial stiffness, so that neglecting the infill would misrepresent both the stiffness and the lateral resistance of the building. In these SAP2000 analyses the infill link has no softening branch, so that its force remains at about 86 kN at PGA = 0.30 g although its deformation of 37.2 mm is far beyond its limit of 15 mm; the revised OpenSees model with softening shows that this simplification overestimated the shear of the base-fixed frame (311 against 250 kN at 0.30 g) and underestimated the drift of its first storey (1.33% against 1.60%; Section 5.12). The dynamic amplification factor of the roof acceleration, 2.08 and 2.17 at the two intensities, did not decrease with the increasing nonlinearity of the response.
The analysis of the test setup (Section 2.2) showed that its loading and boundary conditions are reproduced in the numerical models and that the actuators were used at no more than 27% of their capacity. The vertical load of 62.5 kN per column (axial load ratio 0.03, i.e., 250 kN in the prototype) was kept constant in all tests and parametric analyses, whereas the gravity load of the columns of the five-storey building reaches 560 kN at the base and varies during the earthquake; in the revised model the column links were corrected for the gravity loads by a fiber-section analysis (Section 4.4), which increases the PGA thresholds by 3–7% (Section 5.12), but the dependence of the decoupled infill parameters on the axial load was not studied. Because the axial load influences the stiffness, the strength, and the ductility of RC columns, the links should be recalibrated for the actual axial load level, a point which is also the basis of the limit of 20–25% of the axial capacity in the design rules of Section 4.2.
The two approaches of the strategy follow from these results. For the analyzed frame and the Ulcinj record, the revised model reaches the yield of the infill (0.13%) at a nominal PGA of 0.056 g, the drift of 0.5% at 0.156 g and the drift of 1.0% at 0.191 g (Section 5.9), so that the design approach for the bearing frame (Section 4.2) is adequate only for low and moderate intensities, in which a repairable damage of the infill is acceptable. With the seven spectrum-compatible records, the same limits are reached at 0.091, 0.237 and 0.382 g (Section 5.13). These values are those of the example frame and of the adopted input and give an order of magnitude rather than a general limit: they depend on the strength of the columns, on the thickness, strength and post-peak behavior of the infill and on the frequency content of the ground motion. Above this range, the damage is not repairable, and the first storey becomes a soft storey, as in the SAP2000 analyses at 0.30 g [48].
Isolation changes the nature of the problem. The strength of the isolation level, about 4.3% of the weight for the bearings plus 11.7% for one SF-ED device, limits the shear transmitted to the superstructure to 173 kN at 0.30 g, against 250 kN for the base-fixed frame; the first-storey drift is 0.10% against 1.60%, and the energy dissipated by damage of the superstructure at 0.60 g is 1.5 kN·m against 155 kN·m. However, the superstructure is not completely protected at the largest intensities: with 5% damping, the drift of the second storey reaches the yield drift of the infill from 0.54 g (from 0.42 g with 2% damping), and for two of the seven spectrum-compatible records from 0.63 and 0.79 g. The price of isolation is the displacement of the isolation level, which exceeds the allowable 160 mm with one SF-ED device from 0.67 g for the Ulcinj record and from 0.62 ± 0.09 g for five of the seven spectrum-compatible records, and with the bearings alone from 0.40 g, and the residual displacement (up to 25 mm with one device and up to 48 mm with ψ = 6%), which shows that the bearings must be complemented by a re-centering mechanism or that the residual displacement must be removed after the earthquake.
The SF-ED device limits the isolation displacement: with one device it is 19% smaller than that of the bearings alone at 0.30 g and 42% smaller at 0.60 g, a reduction in the same order as in the shaking-table tests of the 1:4 building model (−43% at the strongest record, 24.2 mm against 42.6 mm [58]). The two results cannot be compared in detail, because the tests used different records and a different structure, but they indicate that the device acts in the analyses as in the tests. However, the device is a compromise, and the ratio ψ of its yield force to the supported weight is the main design parameter (Section 5.10). It is bounded from below by the allowable displacement and from above by the yield shear of the first storey (Equation (11), ψ ≲ 13.7% for the revised model) and, at the highest intensity, by the displacement, which increases again for larger values; the numerical range is 0.0–15.7% at 0.30 g and 5.3–8.8% at 0.70 g, and it does not exist at 0.80 g. Within it, a smaller ψ (about 6%) transmits a much smaller shear and acceleration to the superstructure; for the Ulcinj record, its displacement is similar to that of the reference system, but for the broadband spectrum-compatible records it is larger (Section 5.13), so that the favorable strength ratio depends on the input and on the displacement capacity, and a range of about 6–12% is indicated. With two devices (ψ = 23.4%), the shear transmitted at 0.30 g (252 kN) is that of the base-fixed frame, the infill yields at 0.06 g, and the first storey reaches 1.0% drift at 0.19 g, as in the base-fixed frame, so that this system does not protect the infill, although it keeps the isolation displacement small (26 mm at 0.30 g).
The findings are subject to several limitations. First, the macro-model was checked only against the specimen that also defined its parameters, so that no independent test data have yet been used, and the cyclic parameters of the infill link were not calibrated on cyclic tests; the comparison with the cyclic test M2-A (Appendix B) covers the cycle peak forces and the stiffness degradation, but not the dissipated energy, which cannot be quantified from the plotted loops (Section 3.3 and Section 5.2). Second, the parametric matrix has only three levels of each parameter, monotonic loading, solid infills in full contact with the frame and one frame type with an axial load ratio of 0.03; the calculation forms are valid only for the analyzed combinations within the prototype range (spans 4.0–6.0 m; D = 250, 400 or 500 mm at G = 2.5 MPa, or G = 2.5–5.0 MPa at D = 250 mm), the interpolation error inside a span segment may reach 10–20% (Appendix A), and the decoupled parameters include the frame–infill interaction of this frame type, so that their transfer to frames with different stiffness, reinforcement or axial load has not been verified. Third, the frame analyses use a planar single-bay shear-building model, in which the local shear introduced by the infill at the column ends, three-dimensional effects, openings, and out-of-plane behavior are not represented; one digitized record and seven artificial records were used, and the thresholds depend on the record (Section 5.13). Fourth, the isolation devices are those published for tested scaled models, transferred by similitude (λ = 4), and not designed prototypes; the mass of the base slab was assumed, and the displacement-limiting buffers, the vertical response, and the dependence of friction on velocity and pressure are not modeled. The sensitivity analysis (Section 5.11) shows that the size of the devices and the damping model change the results substantially. The analysis is two-dimensional, so it demonstrates the performance of the isolation in one horizontal direction only; the multidirectional response of the SF-ED device rests on the cited tests [54,55,56,57,58] and is not verified here. Finally, the five design rules of Section 4.2 were formulated from the findings of [42,48] and of this paper and were not applied to a design example.
Although the proposed methodology has been developed and verified for AAC masonry infills within the investigated range of geometrical and mechanical parameters, the underlying micro-to-macro modeling framework is sufficiently general to be extended to other masonry infill systems following appropriate experimental validation and numerical calibration. Future research should therefore investigate its applicability to different masonry materials, alternative infill configurations and more complex three-dimensional structural systems. Cyclic tests of AAC-infilled frames with varied frame properties and axial loads for independent validation, shaking-table tests of an isolated AAC-infilled frame, bidirectional three-dimensional analyses with sets of recorded ground motions, and the design of the devices and of a re-centering solution for a real building are the natural next steps towards performance-based seismic design of masonry-infilled reinforced concrete buildings.
7. Conclusions
This study presented a micro-to-macro nonlinear modeling method for RC frame buildings with AAC masonry infill, based on experimentally validated micro-models, and evaluated a dual strategy for reducing their seismic vulnerability. The experiments and the validation of the micro-models were published in [42]; the parametric study, the decoupling, and the AACF model were developed in [48] and are extended and published here, together with the new OpenSees analyses of the base-fixed and the isolated frame. The following results are directly supported by the present analyses.
The parametric study of 24 scaled models showed that the span governs the deformation characteristics of the infill (for spans from 4.0 to 6.0 m, FM decreases by 19–50%, DM increases by 27–107% and K0 decreases by 51–71%), whereas the thickness has the strongest effect on strength and stiffness (FM increases by a factor of 3.4–4.3 when the thickness is doubled from 250 to 500 mm, from 68 to 232 kN at a span of 4.0 m); increasing the compressive strength from 2.5 to 5.0 MPa raised FM by 36–65%, with a change in DM of at most about 10%.
The uniform decoupling gives the apparent contribution of the AAC infill, including its interaction with the frame, with an uncertainty of about ±4 kN in the scaled models (±11% for the reference configuration). The calculation forms define the parameters of the infill link for the analyzed combinations of span, thickness and strength without further finite element analyses; a leave-one-out check showed that the two span segments are necessary and that no interpolation in thickness or strength is admissible.
The AACF macro-model is consistent with the tested frame: its peak force is 3.1% above the measured one, and with the revised infill link (softening and cyclic degradation) the root-mean-square error over the measured response is 6.8% of the peak force, against 14.7% without softening; this is a consistency check, not an independent validation. The OpenSees implementation reproduced the displacements of the SAP2000 analyses within 6.5%.
For the analyzed five-storey frame and the Ulcinj record, the revised model (infill softening and degradation, P–Δ effects, axial-load-corrected columns, 5% damping) reached the drifts of 0.13%, 0.5% and 1.0% at nominal PGAs of 0.056, 0.156 and 0.191 g; the omission of the softening in the original model had delayed the latter two limits by 17–26%. For the seven spectrum-compatible records, the same limits were reached at 0.091, 0.237 and 0.382 g, so that the thresholds are specific to the structure and the input. Isolation with bearings and one SF-ED device (ψ = 11.7%) reduced the first-storey drift at 0.30 g from 1.60% to 0.10%, kept all storey drifts below 0.13% up to about 0.54 g (Ulcinj, 5% damping) and the isolation displacement within 160 mm up to 0.67 g (Ulcinj) or 0.62 ± 0.09 g (five of seven spectrum-compatible records); the bearings alone exceeded 160 mm from 0.40 g.
The strength ratio ψ of the SF-ED devices is the main design parameter of the isolation. The transmitted shear increases almost linearly with ψ, whereas the isolation displacement decreases only at small values; for the Ulcinj record, the admissible range is 0.0–15.7% at 0.30 g and 5.3–8.8% at 0.70 g and does not exist at 0.80 g. ψ = 6% kept all storey drifts below 0.09% for all records but gave larger isolation displacements than ψ = 11.7% under the spectrum-compatible records, so that a range of about 6–12%, chosen according to the displacement capacity, is indicated. Two devices (ψ = 23.4%) did not protect the infill. The residual displacement at the isolation level (up to 25–48 mm) requires a re-centering solution.
Broader implications that require further validation are the applicability of the calculation forms outside the investigated combinations and to frames with different stiffness, reinforcement or axial load; the predictive capability of the macro-model, in particular of its cyclic law, which should be validated against independent cyclic tests of AAC-infilled frames; the three-dimensional and bidirectional response of the isolated building, for which the multidirectional behavior of the SF-ED device is established only by previous tests; and the design of prototype devices and of a re-centering solution. They should be addressed by cyclic and shaking-table tests and by bidirectional analyses with sets of recorded ground motions.
The micro-to-macro concept itself is general and may be extended to other masonry infill systems after appropriate experimental validation and numerical calibration.
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/buildings16234708/s1: S1: OpenSeesPy scripts of the single-storey and five-storey AACF models (base-fixed and isolated), of the fiber-section analysis and of the generation of the artificial records; S2: the Ulcinj–Albatros record as used (0.22 g, Δt = 0.01 s) and the seven artificial records; S3: numerical results of all analyses and the digitized experimental and micro-model envelopes of Table 15.
Author Contributions
Conceptualization, D.R., V.V., L.M., and J.R.; methodology, V.V. and J.R.; software, V.V. and L.M.; validation, V.V., J.R., and D.R.; formal analysis, V.V., L.M., and D.R.; investigation, V.V.; resources, L.M. and D.R.; data curation, V.V.; writing—original draft preparation, V.V.; writing—review and editing, L.M., J.R., and D.R.; visualization, V.V.; supervision, J.R. and D.R. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
The OpenSees scripts, the accelerograms, and the numerical results of this study are provided as Supplementary Materials S1–S3. The raw data of the tests belong to the experimental program of [42] and are available from the corresponding author on reasonable request.
Acknowledgments
The authors would like to acknowledge the ReSIN Laboratory of Industrial Sciences and Technologies, Skopje, for providing the laboratory facilities, technical support and resources for the realization of the specific joint experimental investigations. The results of the experimental program, together with the calibration and validation of the detailed nonlinear finite element models, constitute the experimental and analytical foundation of the Ph.D. dissertation of V.V., upon which the present study is based. During the preparation of this manuscript, the authors used ChatGPT (OpenAI, GPT-5.5) and Claude (Anthropic) to assist with language editing, grammar refinement, and improvement of scientific writing. All AI-assisted outputs were carefully reviewed, verified, and edited by the authors, who take full responsibility for the scientific content, analyses, and conclusions presented in this manuscript.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations and Symbols
The following abbreviations and symbols are used in this manuscript: AAC, autoclaved aerated concrete; AACF, AAC frame macro-model; CHHA and CVHA, connecting supports of the horizontal and the vertical hydraulic actuators; DAF, dynamic amplification factor; DSSSB, double spherical sliding bearing; HHA and VHA, horizontal and vertical hydraulic actuators; LTF, laboratory testing frame; MIS, model installation system; PGA, peak ground acceleration; RC, reinforced concrete; SF-ED, space-flange energy-dissipation device; L, frame span; D, infill thickness; G, AAC compressive strength; FM and DM, maximum force of the decoupled infill and the corresponding displacement; FY and DY, force and displacement at the point of significant stiffness change; FU and DU, force and displacement at the point of maximum strength of a link; FL and DL, force and displacement at the last point of the envelope; Df, deformation limit of a link; K0, initial stiffness; N1, vertical load per column; Da, allowable displacement of the isolation level; Diso, isolation displacement; Teff, effective period of the isolation level; W, weight supported by the isolation level; Vy,1, yield shear of the first storey; ψ = ΣFY/W, ratio of the total yield force of the SF-ED devices to W; λ, scale factor of the device model; RMSE, root-mean-square error; ζ, damping ratio of the superstructure.
Appendix A. Check of the Interpolation of the Calculation Forms
No micro-model results exist at intermediate values of the parameters, so the linear interpolation of the forms of Table 8 was checked by a leave-one-out test: the value at the middle node was predicted by linear interpolation between the outer nodes and compared with the computed value (Table A1). In the span, a single linear relation between 400 and 600 cm would be in error by −4% to +9% for four forms but by +58% for Form 2, and by −5% to −23% for DM; in the thickness (scaled models, D = 200 mm between 125 and 250 mm), FM is predicted within 3% at L = 200 cm but overestimated by 70% and 55% at 250 and 300 cm. The two span segments of Table 8 are therefore necessary; the interpolation error inside a segment cannot be quantified with the available data and may reach 10–20%, and no interpolation in thickness or strength is admissible.
Table A1.
Leave-one-out check of the linear interpolation of the calculation forms: values at L = 500 cm predicted from the values at 400 and 600 cm (prototype) and computed values (Table 9).
Appendix B. Comparison of the AACF Model with the Cyclic Test M2-A
The single-storey AACF model was subjected to the displacement history of the cyclic test M2-A of [42,48] (one cycle at each amplitude, peaks read from the recorded loops; Table A2, Figure A1). The measured envelope has the characteristic points Y (1.1 mm, 60 kN), U (5.6 mm, 85 kN) and L (12 mm, 33 kN) in both directions, i.e., a peak resistance close to that of the monotonic test M2-B (80 kN). With the original infill link, the strength after the peak hardly decreases (by 10% and 8% from the peak cycle to the last cycle at about 9 mm in the positive and negative directions), whereas the test shows 31% and 28%; the revised link with softening and degradation gives 28% and 23%. The peak-to-peak stiffness decreases in the test from 26.2 kN/mm at 2.6 mm to 6.8 kN/mm at 8.9 mm, and in the revised model from 27.2 to 6.1 kN/mm (original: 28.4 to 8.2 kN/mm). The root-mean-square error of the ten-cycle peak forces is 9.8 kN for the original and 11.4 kN for the revised link; it is dominated by the asymmetry of the test (the negative peaks at 5.5 and 7.5 mm are 7% and 24% larger than the positive ones) and by the first small cycle, whose peak is uncertain. In the positive direction, after the first cycle, the revised link is within −9% to +7% of the measured peaks, and the original one is within −2% to +28%. The energy dissipated in the test could not be quantified from the plotted loops. Because the test belongs to the same program as the monotonic test used to derive the model, the comparison is a consistency check of the cyclic law and not an independent validation.
Table A2.
Peak forces of the cycles and peak-to-peak secant stiffness Kpp of the cyclic test M2-A and of the AACF model with the original and with the revised infill link (single-storey model, displacement history of the test).
Figure A1.
Comparison with the cyclic test M2-A: (a) hysteresis loops of the AACF model with the original and with the revised infill link under the displacement history of the test, with the measured cycle peaks and the envelope of the test [48]; (b) peak forces of the cycles in the positive (dark) and negative (light) direction; (c) peak-to-peak secant stiffness of the cycles.
References
- RILEM Recommended Practice. Autoclaved Aerated Concrete: Properties, Testing and Design; RILEM Technical Committees 78-MCA and 51-ALC; E & FN Spon: London, UK, 1993. [Google Scholar]
- Raj, A.; Borsaikia, A.C.; Dixit, U.S. Evaluation of Mechanical Properties of Autoclaved Aerated Concrete (AAC) Block and Its Masonry. J. Inst. Eng. India Ser. A 2020, 101, 315–325. [Google Scholar] [CrossRef] [Scilit]
- Rafiza, A.R.; Fazlizan, A.; Thongtha, A.; Asim, N.; Noorashikin, M.S. The Physical and Mechanical Properties of Autoclaved Aerated Concrete (AAC) with Recycled AAC as a Partial Replacement for Sand. Buildings 2022, 12, 60. [Google Scholar] [CrossRef] [Scilit]
- Vicente, R.; Rodrigues, H.; Varum, H.; Costa, A.; Mendes da Silva, J.A.R. Performance of Masonry Enclosure Walls: Lessons Learned from Recent Earthquakes. Earthq. Eng. Eng. Vib. 2012, 11, 23–34. [Google Scholar] [CrossRef] [Scilit]
- Murty, C.V.R.; Brzev, S.; Faison, H.; Comartin, C.D.; Irfanoglu, A. At Risk: The Seismic Performance of Reinforced Concrete Frame Buildings with Masonry Infill Walls; EERI Publication WHE-2006-03; Earthquake Engineering Research Institute: Oakland, CA, USA, 2006. [Google Scholar]
- Messaoudi, A.; Chebili, R.; Mohamed, H.; Rodrigues, H. Influence of Masonry Infill Wall Position and Openings in the Seismic Response of Reinforced Concrete Frames. Appl. Sci. 2022, 12, 9477. [Google Scholar] [CrossRef] [Scilit]
- Furtado, A.; Rodrigues, H.; Arede, A.; Varum, H. Simplified Macro-Model for Infill Masonry Walls Considering the Out-of-Plane Behaviour. Earthq. Eng. Struct. Dyn. 2016, 45, 507–524. [Google Scholar] [CrossRef] [Scilit]
- Polyakov, S.V. On the Interaction between Masonry Filler Walls and Enclosing Frame When Loaded in the Plane of the Wall. In Translations in Earthquake Engineering; EERI: Oakland, CA, USA, 1960; pp. 36–42. [Google Scholar]
- Holmes, M. Steel Frames with Brickwork and Concrete Infilling. Proc. Inst. Civ. Eng. 1961, 19, 473–478. [Google Scholar] [CrossRef] [Scilit]
- Stafford Smith, B. Lateral Stiffness of Infilled Frames. J. Struct. Div. ASCE 1962, 88, 183–199. [Google Scholar] [CrossRef] [Scilit]
- Stafford Smith, B.; Carter, C. A Method of Analysis for Infilled Frames. Proc. Inst. Civ. Eng. 1969, 44, 31–48. [Google Scholar] [CrossRef] [Scilit]
- Mainstone, R.J. On the Stiffness and Strengths of Infilled Frames. Proc. Inst. Civ. Eng. 1971, 49, 57–90. [Google Scholar] [CrossRef] [Scilit]
- Klingner, R.E.; Bertero, V.V. Earthquake Resistance of Infilled Frames. J. Struct. Div. ASCE 1978, 104, 973–989. [Google Scholar] [CrossRef] [Scilit]
- Saneinejad, A.; Hobbs, B. Inelastic Design of Infilled Frames. J. Struct. Eng. ASCE 1995, 121, 634–650. [Google Scholar] [CrossRef] [Scilit]
- Panagiotakos, T.B.; Fardis, M.N. Seismic Response of Infilled RC Frame Structures. In Proceedings of the 11th World Conference on Earthquake Engineering, Acapulco, Mexico, 23–28 June 1996. Paper No. 225. [Google Scholar]
- Fardis, M.N.; Panagiotakos, T.B. Seismic Design and Response of Bare and Masonry-Infilled Reinforced Concrete Buildings. Part II: Infilled Structures. J. Earthq. Eng. 1997, 1, 475–503. [Google Scholar] [CrossRef] [Scilit]
- Dolsek, M.; Fajfar, P. The Effect of Masonry Infills on the Seismic Response of a Four-Storey Reinforced Concrete Frame—A Deterministic Assessment. Eng. Struct. 2008, 30, 1991–2001. [Google Scholar] [CrossRef] [Scilit]
- Crisafulli, F.J. Seismic Behaviour of Reinforced Concrete Structures with Masonry Infills. Ph.D. Thesis, University of Canterbury, Christchurch, New Zealand, 1997. [Google Scholar]
- Crisafulli, F.J.; Carr, A.J. Proposed Macro-Model for the Analysis of Infilled Frame Structures. Bull. N. Z. Soc. Earthq. Eng. 2007, 40, 69–77. [Google Scholar] [CrossRef] [Scilit]
- Cavaleri, L.; Di Trapani, F. Cyclic Response of Masonry Infilled RC Frames: Experimental Results and Simplified Modeling. Soil Dyn. Earthq. Eng. 2014, 65, 224–242. [Google Scholar] [CrossRef] [Scilit]
- Uva, G.; Raffaele, D.; Porco, F.; Fiore, A. On the Role of Equivalent Strut Models in the Seismic Assessment of Infilled RC Buildings. Eng. Struct. 2012, 42, 83–94. [Google Scholar] [CrossRef] [Scilit]
- Asteris, P.G.; Antoniou, S.T.; Sophianopoulos, D.S.; Chrysostomou, C.Z. Mathematical Macromodeling of Infilled Frames: State of the Art. J. Struct. Eng. ASCE 2011, 137, 1508–1517. [Google Scholar] [CrossRef] [Scilit]
- Di Trapani, F.; Macaluso, G.; Cavaleri, L.; Papia, M. Masonry Infills and RC Frames Interaction: Literature Overview and State of the Art of Macromodeling Approach. Eur. J. Environ. Civ. Eng. 2015, 19, 1059–1095. [Google Scholar] [CrossRef] [Scilit]
- Skafida, S.; Koutas, L.; Bousias, S.N. Analytical Modeling of Masonry Infilled RC Frames and Verification with Experimental Data. J. Struct. 2014, 2014, 216549. [Google Scholar] [CrossRef] [Scilit]
- Chrysostomou, C.Z.; Asteris, P.G. On the In-Plane Properties and Capacities of Infilled Frames. Eng. Struct. 2012, 41, 385–402. [Google Scholar] [CrossRef] [Scilit]
- Dias-Oliveira, J.; Rodrigues, H.; Asteris, P.G.; Varum, H. On the Seismic Behavior of Masonry Infilled Frame Structures. Buildings 2022, 12, 1146. [Google Scholar] [CrossRef] [Scilit]
- Liu, C.; Liu, B.; Wang, X.; Kong, J.; Gao, Y. Seismic Performance Target and Fragility of Masonry Infilled RC Frames under In-Plane Loading. Buildings 2022, 12, 1175. [Google Scholar] [CrossRef] [Scilit]
- Gaetani d’Aragona, M.; Polese, M.; Di Ludovico, M.; Prota, A. Seismic Vulnerability for RC Infilled Frames: Simplified Evaluation for As-Built and Retrofitted Building Typologies. Buildings 2018, 8, 137. [Google Scholar] [CrossRef] [Scilit]
- Asteris, P.G.; Cotsovos, D.M.; Chrysostomou, C.Z.; Mohebkhah, A.; Al-Chaar, G.K. Mathematical Micromodeling of Infilled Frames: State of the Art. Eng. Struct. 2013, 56, 1905–1921. [Google Scholar] [CrossRef] [Scilit]
- Mehrabi, A.B.; Shing, P.B.; Schuller, M.P.; Noland, J.L. Experimental Evaluation of Masonry-Infilled RC Frames. J. Struct. Eng. ASCE 1996, 122, 228–237. [Google Scholar] [CrossRef] [Scilit]
- Lourenço, P.B. Computational Strategies for Masonry Structures. Ph.D. Thesis, Delft University of Technology, Delft, The Netherlands, 1996. [Google Scholar]
- Nasiri, E.; Liu, Y. Development of a Detailed 3D FE Model for Analysis of the In-Plane Behaviour of Masonry Infilled Concrete Frames. Eng. Struct. 2017, 143, 603–616. [Google Scholar] [CrossRef] [Scilit]
- Mucedero, G.; Perrone, D.; Brunesi, E.; Monteiro, R. Numerical Modelling and Validation of the Response of Masonry Infilled RC Frames Using Experimental Testing Results. Buildings 2020, 10, 182. [Google Scholar] [CrossRef] [Scilit]
- Mohebkhah, A.; Tasnimi, A.A.; Moghadam, H.A. Nonlinear Analysis of Masonry-Infilled Steel Frames with Openings Using Discrete Element Method. J. Constr. Steel Res. 2008, 64, 1463–1472. [Google Scholar] [CrossRef] [Scilit]
- Kaushik, H.B.; Rai, D.C.; Jain, S.K. Stress-Strain Characteristics of Clay Brick Masonry under Uniaxial Compression. J. Mater. Civ. Eng. ASCE 2007, 19, 728–739. [Google Scholar] [CrossRef] [Scilit]
- Binici, B.; Canbay, E.; Aldemir, A.; Demirel, I.O.; Uzgan, U.; Eryurtlu, Z.; Bulbul, K.; Yakut, A. Seismic Behavior and Improvement of Autoclaved Aerated Concrete Infill Walls. Eng. Struct. 2019, 193, 68–81. [Google Scholar] [CrossRef] [Scilit]
- Giulivo, M.; Borretti, G.; Prota, A.; Menna, C. Out-of-Plane Behavior of Innovative Infill Walls Made of Autoclaved Aerated Concrete (AAC) Subjected to Shake Table Tests. Front. Built Environ. 2023, 9, 1168241. [Google Scholar] [CrossRef] [Scilit]
- Tanner, J.E.; Varela, J.L.; Klingner, R.E.; Brightman, M.J.; Cancino, U. Seismic Testing of Autoclaved Aerated Concrete Shear Walls: A Comprehensive Review. ACI Struct. J. 2005, 102, 374–382. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, X.; Xiong, L.; Wang, Z. Simplified Model Study of Autoclaved Aerated Concrete Masonry Flexible Connection Infilled Frames with Basalt Fiber Grating Strips. Buildings 2024, 14, 1033. [Google Scholar] [CrossRef] [Scilit]
- Li, X.; Ma, D.; Zhang, Q.; Zhang, Z.; Bao, H.; Yao, Y. Seismic Performance of Full-Scale Autoclaved Aerated Concrete Panel-Assembled Walls: Experimental Study and Numerical Modeling. Buildings 2024, 14, 1333. [Google Scholar] [CrossRef] [Scilit]
- Di Sarno, L.; Albuhairi, D. Reinforced Autoclaved Aerated Concrete: Structural Assessment and Retrofitting. Buildings 2024, 14, 2570. [Google Scholar] [CrossRef] [Scilit]
- Veseli, V.; Misini, L.; Ristic, J.; Churilov, S.; Ristic, D. Upgraded Seismic Protection Strategy for AAC-Infilled RC Frames: Experimental Testing and Micro-Modelling. Civ. Eng. J. 2026, 12, 3842–3866. [Google Scholar] [CrossRef] [Scilit]
- EN 1998-1; Eurocode 8: Design of Structures for Earthquake Resistance—Part 1: General Rules, Seismic Actions and Rules for Buildings. European Committee for Standardization (CEN): Brussels, Belgium, 2004.
- EN 1996-1-1; Eurocode 6: Design of Masonry Structures—Part 1-1: General Rules for Reinforced and Unreinforced Masonry Structures. European Committee for Standardization (CEN): Brussels, Belgium, 2005.
- Applied Technology Council. Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings—Basic Procedures Manual; FEMA 306; ATC/FEMA: Washington, DC, USA, 1998. [Google Scholar]
- Federal Emergency Management Agency. Prestandard and Commentary for the Seismic Rehabilitation of Buildings; FEMA 356; FEMA: Washington, DC, USA, 2000.
- ASCE/SEI 41-17; Seismic Evaluation and Retrofit of Existing Buildings. American Society of Civil Engineers: Reston, VA, USA, 2017.
- Veseli, V. Development of Seismically Safe Reinforced Concrete Framed Building Systems with Autoclaved Aerated Concrete (AAC) Infill Based on Nonlinear Experimental and Analytical Investigation. Ph.D. Thesis, Ss. Cyril and Methodius University in Skopje, Faculty of Civil Engineering, Skopje, North Macedonia, 2026. [Google Scholar]
- Kelly, J.M. Aseismic Base Isolation: Review and Bibliography. Soil Dyn. Earthq. Eng. 1986, 5, 202–216. [Google Scholar] [CrossRef] [Scilit]
- Naeim, F.; Kelly, J.M. Design of Seismic Isolated Structures: From Theory to Practice; John Wiley & Sons: New York, NY, USA, 1999. [Google Scholar]
- Zayas, V.A.; Low, S.S.; Mahin, S.A. A Simple Pendulum Technique for Achieving Seismic Isolation. Earthq. Spectra 1990, 6, 317–333. [Google Scholar] [CrossRef] [Scilit]
- Mokha, A.; Constantinou, M.; Reinhorn, A. Teflon Bearings in Base Isolation I: Testing. J. Struct. Eng. 1990, 116, 438–454. [Google Scholar] [CrossRef] [Scilit]
- Skinner, R.I.; Kelly, J.M.; Heine, A.J. Hysteretic Dampers for Earthquake-Resistant Structures. Earthq. Eng. Struct. Dyn. 1974, 3, 287–296. [Google Scholar] [CrossRef] [Scilit]
- Ristic, J. Modern Technology for Seismic Protection of Bridge Structures Applying Advanced System for Modification of Earthquake Response. Ph.D. Thesis, Institute of Earthquake Engineering and Engineering Seismology (IZIIS), Ss. Cyril and Methodius University, Skopje, North Macedonia, 2016. [Google Scholar]
- Guri, Z.; Ristić, D.; Misini, M.; Ristić, J.; Pllana, N. Seismic Upgrading of Bridges Isolated with SF-ED Devices: Large-Scale Model Testing on Shaking Table. Građevinar 2018, 70, 463–485. [Google Scholar] [CrossRef] [Scilit]
- Misini, M.; Ristic, J.; Ristic, D.; Guri, Z.; Pllana, N. Seismic Upgrading of Isolated Bridges with SF-ED Devices: Analytical Study Validated by Shaking Table Testing. Građevinar 2019, 71, 255–272. [Google Scholar] [CrossRef] [Scilit]
- Ristic, J.; Brujic, Z.; Ristic, D.; Folic, R.; Boskovic, M. Upgrading of Isolated Bridges with Space-Bar Energy-Dissipation Devices: Shaking Table Test. Adv. Struct. Eng. 2021, 24, 2948–2965. [Google Scholar] [CrossRef] [Scilit]
- Ristic, J.; Veseli, V.; Misini, L.; Ristic, D. Seismic Protection of Masonry and Infilled Frame Buildings Using Upgraded Sliding Isolation System with SF Devices. In Proceedings of the 2nd Croatian Conference on Earthquake Engineering—2CroCEE, Zagreb, Croatia, 22–24 March 2023. [Google Scholar] [CrossRef] [Scilit]
- Ristic, J.; Hajdari, V.; Misini, L.; Ristic, D. Combined Protection of Bridges Exposed to Earthquake and Flood Disasters with New RB-Upgraded Isolation System. In Proceedings of the 2nd Croatian Conference on Earthquake Engineering—2CroCEE, Zagreb, Croatia, 22–24 March 2023. [Google Scholar] [CrossRef] [Scilit]
- Takeda, T.; Sozen, M.A.; Nielsen, N.N. Reinforced Concrete Response to Simulated Earthquakes. J. Struct. Div. ASCE 1970, 96, 2557–2573. [Google Scholar] [CrossRef] [Scilit]
- Computers and Structures, Inc. (CSI). SAP2000: Integrated Software for Structural Analysis and Design; CSI: Berkeley, CA, USA, 2021. [Google Scholar]
- Lourenço, P.B.; Rots, J.G. Multisurface Interface Model for Analysis of Masonry Structures. J. Eng. Mech. 1997, 123, 660–668. [Google Scholar] [CrossRef] [Scilit]
- Lowes, L.N.; Mitra, N.; Altoontash, A. A Beam-Column Joint Model for Simulating the Earthquake Response of Reinforced Concrete Frames; PEER Report 2003/10; Pacific Earthquake Engineering Research Center: Berkeley, CA, USA, 2004; Available online: https://peer.berkeley.edu/publications/2003-10 (accessed on 4 November 2026).
- Gasparini, D.A.; Vanmarcke, E.H. Simulated Earthquake Motions Compatible with Prescribed Response Spectra; Report R76-4; Massachusetts Institute of Technology: Cambridge, MA, USA, 1976; Available online: http://nisee.berkeley.edu/elibrary/Text/61000173 (accessed on 4 November 2026).
- Nigam, N.C.; Jennings, P.C. Calculation of Response Spectra from Strong-Motion Earthquake Records. Bull. Seismol. Soc. Am. 1969, 59, 909–922. [Google Scholar] [CrossRef] [Scilit]
- McKenna, F. OpenSees: A Framework for Earthquake Engineering Simulation. Comput. Sci. Eng. 2011, 13, 58–66. [Google Scholar] [CrossRef] [Scilit]
- Zhu, M.; McKenna, F.; Scott, M.H. OpenSeesPy: Python Library for the OpenSees Finite Element Framework. SoftwareX 2018, 7, 6–11. [Google Scholar] [CrossRef] [Scilit]
- Newmark, N.M. A Method of Computation for Structural Dynamics. J. Eng. Mech. Div. 1959, 85, 67–94. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |