Abstract
Recent studies have highlighted the effectiveness of semi-active control strategies in optimizing the energy components of the seismic response of plan-asymmetric structures. However, this effectiveness is generally demonstrated through response quantities averaged over broad record sets, which obscures its dependence on site conditions and on the frequency and impulsive content of the excitation. This study presents a closed-form, energy-driven control framework for viscoelastic semi-active devices in one-way asymmetric systems and performs a disaggregated parametric analysis of the elastic- and kinetic-energy minimization algorithms. Using 85 far-field and near-fault records, seismic performance is examined as a function of translational period and structural eccentricity, and then broken down by EC8 soil class and record character. In addition to conventional peak and mean measures, the median reduction, its interquartile dispersion and coefficient of variation are introduced, together with correlations between energy reduction and signal indicators, namely the PGA/PGV ratio and the specific energy density. The kinetic-energy algorithm proves strongly governed by the frequency content of the excitation, whereas the elastic-energy algorithm is uncorrelated with either indicator; both algorithms are less effective on soft-soil and near-fault records. The results are organized into algorithm-selection maps supporting design choices for a given site and expected demand.
1. Introduction
Theoretical and experimental studies have shown that high-intensity seismic events produce markedly more severe effects in structural systems with a non-uniform in-plan distribution of mass and stiffness. Such plan-asymmetric structures develop a coupling between lateral and torsional motion that concentrates the seismic demand on the flexible edges of the deck and, in general, renders these systems more vulnerable than their nominally regular counterparts [1,2]. The lesson has been reiterated by subsequent earthquakes: a detailed survey of the damage caused by the 1985 Mexico City earthquake showed that a large fraction of the collapsed buildings exhibited significant irregularities in the distribution of strength and stiffness, both in elevation and in plan [3], while during the 1999 Kocaeli earthquake several structures were severely damaged because partial retrofits, carried out to repair earlier minor damage, had inadvertently increased their stiffness asymmetry [4]. More recently, the 2023 Türkiye–Syria earthquake sequence again produced substantial damage in buildings whose reinforcement operations had been conceived without adequately accounting for their effect on the stiffness distribution and the consequent activation of large torsional moments [5]. Even base-isolated buildings, often regarded as intrinsically robust, prove more vulnerable when a marked asymmetry is present, as shown by dynamic analyses of an L-shaped isolated structure subjected to the 2011 Tohoku earthquake [6].
Despite decades of research, the dynamic response of plan-asymmetric systems continues to pose open problems, which may be summarized, although not exhaustively, as the difficulty of identifying and measuring the level of irregularity induced by asymmetry, and the difficulty of selecting analysis and design methods, in both the linear and the nonlinear range, capable of delivering a reliable estimate of the seismic demand [7].
For many years these systems have been investigated with the aim of mitigating the lateral–torsional response through appropriate design strategies [8,9,10]. Two research directions have subsequently developed: the study of the seismic response through nonlinear static procedures and the assessment of their reliability [11,12,13,14,15,16,17], and the use of control devices to rebalance the seismic demand among the different components of the structural system. The latter direction has advanced rapidly, yielding promising results in terms of practical application, both due to the high performance levels attainable and the increasingly mature technology available.
Against this background, a broad range of supplemental energy-dissipation devices has been developed: viscous, viscoelastic, frictional, and metallic (X-plate) dampers, together with tuned mass and tuned liquid dampers in their various and combined forms [18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38]. These passive solutions are effective but share an intrinsic limitation: their properties are fixed at the design stage and cannot adapt to the actual demand, which is particularly restrictive for asymmetric systems, where the optimal balance between lateral and torsional control varies with the characteristics of the excitation. This motivates the shift toward semi-active devices, whose stiffness and damping can be tuned in real time at negligible power cost while retaining the fail-safe reliability of passive systems. Among them, magnetorheological (MR) devices occupy a prominent position: their fluid changes viscosity in response to an applied magnetic field, allowing a rapid and controllable variation of the damping level, and they revert gracefully to a passive device in the event of power loss [39,40,41,42,43,44]. Semi-active tuned mass dampers, whose damping and frequency are adapted on-line, have likewise been shown to outperform their optimal passive counterparts and to remain effective when integrated within base-isolated or health-monitored structures [45,46,47,48].
Despite the numerous technological solutions currently available, the control of plan-asymmetric structures remains an incompletely resolved problem: most studies on semi-active systems address primarily the translational response, devoting considerably less attention to the coupled torsional response, a serious limitation, since real structures often exhibit strong interaction between lateral and torsional motion, which amplifies the demand and increases vulnerability. Beyond the hardware, however, the effectiveness of any semi-active device ultimately rests on the algorithm that drives it in real time, and it is here that the theoretical and practical questions remain most open, since the control action must arbitrate between lateral and torsional demands.
Among the earliest such algorithms, those proposed by McClamroch and Gavin for electrorheological devices derived, through a Lyapunov-based synthesis, a bang-bang control law that minimizes the seismic energy transmitted to the structure [49]. Dyke et al. subsequently proposed a clipped-optimal strategy, based on acceleration feedback, for the control of MR dampers, showing that the semi-active system can approach and even surpass the performance of a linear active controller while requiring only a fraction of its power [50]. Sadek and Mohraz compared three algorithms: a linear quadratic regulator, a generalized quadratic regulator with acceleration penalization, and a displacement–acceleration domain algorithm, for the semi-active mitigation of plan-asymmetric systems [51]. Li and Gu reproduced the optimal action of a linear quadratic Riccati controller through passive viscous devices by means of a minimum-norm method [52]. Pnevmatikos and Hatzigeorgiou introduced a pole-placement algorithm, applicable to both active and semi-active devices, built on a fictitious symmetric structure to which suitable poles are assigned [53]. Sever et al. presented an optimal controller based on linear matrix inequalities, demonstrating effective vibration reduction and guaranteed stability of the asymmetric system in both the frequency and the time domain [54].
These algorithms are effective in reducing the translational response, but they are not specifically tailored to the torsional effects that characterize asymmetric buildings and, more importantly for the present discussion, they generally lack a transparent physical interpretation, a shortcoming that hinders a full understanding of their effectiveness and of their robustness. A useful interpretation is provided by the concept of energy and of the energy balance, introduced by Goel in the context of the seismic response of asymmetric systems [55] and, more generally, by Yanik et al. in the field of structural control [56].
Algorithms that act on energy itself, instead of using it only to read a response, are few, and they differ in ways that bear directly on the present study. The Lyapunov-based law recalled above [49] pursues one global quantity, the energy transmitted to the structure, through a bang-bang action; the scheme of Zelleke and Matsagar [57] also works on an energy measure, but it is predictive in nature and is formulated for a tuned mass damper, not for devices distributed in plan. The framework recently proposed by some of the present authors [58,59] departs from both along three lines. It offers a family of alternative laws, each driving a single term of the energy balance (the dissipated, elastic, kinetic or input energy) in the desired direction at every instant; it modulates stiffness as well as damping, device by device; and the switching condition of each device is a closed-form function of the instantaneous kinematics at its own position, so that the lateral–torsional coupling enters every decision without any model, or any prediction, of the excitation. That framework, which generalizes to semi-active devices an earlier energy-based approach formulated for viscous devices, was validated through an extensive parametric campaign spanning a wide range of structural parameters and a suite of 85 far-field and near-fault records [60], and it was benchmarked against passive control and against well-established semi-active laws such as the Kamagata & Kobori [61,62] and sky-hook algorithms [63,64,65]. Its principal appeal is the explicit, interpretable link between the control action and the mechanical quantity being optimized.
The effectiveness of that framework, however, was reported chiefly in aggregate form, as peak and mean energy demands averaged over the full record suite, and the same is true of most of the studies recalled above, which document performance on selected records or as an average over a suite; to the authors’ knowledge, how the performance of these algorithms changes with the site and with the impulsive character of the input has not been examined systematically. For plan-asymmetric systems an average is more than a coarse summary; it is poorly suited to the problem. The lateral–torsional coupling concentrates the demand on the flexible edge according to the instantaneous phase between translation and rotation, and that phase is in turn set by the frequency content and by the impulsiveness of the input. An average over records therefore pools cases in which the coupling is excited in different ways, and returns an intermediate level that may describe none of them. Averaged descriptors remain indispensable for establishing overall effectiveness, but they cannot show how the performance of each control law depends on the characteristics of the site and of the excitation. This dependence matters in engineering practice, since the frequency content of the ground motion, quantified for instance by the ratio of peak ground acceleration to peak ground velocity, its impulsive or non-impulsive nature, its energy severity, and the stiffness of the recording site, codified in the EC8 soil classification, are known to govern the seismic demand on asymmetric systems [59,60,66], and there is no a priori reason to expect a single control law to be uniformly effective across all of these conditions. An assessment that resolves effectiveness along these axes, rather than averaging over them, can therefore indicate which strategy is preferable for a given site and expected demand, and quantify the scatter of the reduction provided by each strategy in addition to its average value.
Motivated by these considerations, the present study translates the effectiveness of the energy-based control laws for one-way plan-asymmetric systems into analytical terms. To this end, the peak energy demands obtained from the validated model are disaggregated along three engineering-relevant axes: the EC8 soil class of the recording site; the far-field or near-fault character of the excitation, which encodes the presence of an impulsive velocity pulse; and two continuous signal descriptors, the PGA/PGV ratio and the specific energy density, taken as proxies for the frequency content and the energy severity of the record, respectively. In addition to conventional peak and mean measures, robustness-oriented metrics, the percentage reduction relative to the uncontrolled case, its median and interquartile dispersion, and its coefficient of variation, are introduced, together with rank correlations between the achieved reduction and the signal descriptors. This analysis shows dependencies that are not visible in aggregate results and partly refines the findings of the base study, in particular regarding the relative effectiveness of the strategies on near-fault as opposed to far-field excitations.
The novelty of the present contribution lies in the site- and signal-resolved characterization of controller effectiveness and in the associated robustness metrics. The remainder of the manuscript is organized as follows. Section 2 recalls, to the extent needed to render the analysis self-contained, the one-way asymmetric model, its energy balance, the closed-form control laws, and the record set. Section 3 describes the ground-motion records and the structural cases considered in the study, while Section 4 introduces the disaggregation variables and the robustness metrics that form the methodological core of the work. The results are then presented and discussed in Section 5, with particular emphasis on the effectiveness across soil classes, the comparison between far-field and near-fault records, the correlations with the signal descriptors, and the dispersion of the achieved reduction. Building on these findings, Section 6 synthesizes the results into algorithm-selection maps, identifying, for each record group, translational period, and amount of supplemental stiffness and damping, the control law associated with the lowest median peak edge displacement, and probes how far that ranking is affected by a finite response time of the devices. Finally, Section 7 summarizes the main conclusions and discusses the limitations of the study, while outlining the directions for future developments.
2. General Numerical Framework and Energetic Semiactive Control Algorithms
A single-storey system is considered and represented in Figure 1, whose in-plan response is described in a reference frame centred at the centre of mass OM, with the x-axis directed along the line joining the centre of mass (OM) to the centre of stiffness (OK). The system is one-way: the supplemental stiffness and damping resources are arranged along the y direction only, so that they mitigate the torsional response without introducing an additional component of eccentricity. Two degrees of freedom are retained: the translation y of the centre of mass and the deck rotation θ about a vertical axis through OM. The displacement of the centre of mass due to the seismic action is denoted by ug, and the absolute displacement is consequently indicated as Y = y + ug.
Figure 1.
Asymmetrical plan-wise system equipped with viscoelastic semi-active devices [59].
For clarity, the symbols appearing in the model and in the energy equations below are defined as follows:
- •
- l: characteristic length of the system in the x direction;
- •
- ekx, eKx, eCx: structural, extra-structural stiffness and damping eccentricities;
- •
- ρM, ρk, ρK, ρC: mass, structural stiffness, extra-structural stiffness and damping radius of gyration;
- •
- ky, Ky: overall structural and extra-structural lateral stiffness in the y direction;
- •
- Cy: overall extra-structural damping;
- •
- rK = Ky/ky stiffness ratio;
- •
- translational natural frequency;
- •
- ξy = Cy/(2Mωy) equivalent extra-structural damping coefficient;
- •
- εkx = ekx/l, εKx = eKx/l, εCx = eCx/l dimensionless eccentricities of the structural stiffness, of the extra-structural stiffness and of the extra-structural damping;
- •
- : mass, structural stiffness, extra-structural stiffness and damping non-dimensional radius of gyration;
The equations of motion governing the dynamics of the system subject to a seismic input signal , in which the two degrees of freedom represent the displacement of the centre of mass along the y direction and the rotation of the deck around a vertical axis passing through the centre of mass, θ, can be written in dimensionally homogeneous form, considering a 2% Rayleigh damping introduced by means of the coefficients α and β, as follows [59]:
Collecting the relative-displacement components in the vector , the equations of motion (1) and (2) can be compactly rewritten in matrix form as follows:
where
- •
- relative displacement vector;
- •
- mass matrix;
- •
- structural stiffness matrix;
- •
- extra-structural stiffness matrix;
- •
- extra-structural damping matrix;
- •
- influence vector.
The model is completed by the following kinematic assumptions and initial conditions. The deck behaves as a rigid body in its own plane and is supported by lateral resisting elements and by supplemental devices that act in the y direction only, as stated above for the one-way configuration; every element is fixed at its base to the ground, which moves rigidly along y under the input , so that neither soil–structure interaction nor base flexibility is modelled. Motion along x and out-of-plane is restrained, which leaves y and θ as the only free coordinates, and no external torsional restraint is applied beyond the restoring and damping actions of K, Kd and Cd. Equation (3) is integrated from rest, U(t = tin) = 0 and , where tin is the onset of the recorded motion, up to the end of the record.
Premultiplying the terms of Equation (3) by the row vector and integrating with respect to time between the beginning, tin, and the end, tfin, of the incoming seismic excitation, yields Equation (4), which expresses the dynamic balance in terms of energetic rates:
where
EK + Eξ,y + Eξ,yθ + Eξ,θ + Eel = Ein
- •
- kinetic energy;
- •
- translational component of the dissipated energy;
- •
- torsional component of the dissipated energy;
- •
- rotational component of the dissipated energy;
- •
- elastic energy;
- •
- input energy.
Imposing that the instantaneous variation of a chosen energy term be driven in the desired direction leads, in closed form, to the semi-active control laws of the framework. Their derivation is not reproduced here; only the three laws examined in this study are stated, in dimensionless form, with Cyi and Kyi denoting the extra-structural damping and stiffness, respectively, of the i-th of N devices, and εCi = xCi/l and εKi = xKi/l, denoting the corresponding dimensionless positions. The complete derivation and the graphical activation domains are given in [59]. In each law the rule is the same: a device is assigned, at every instant, to the bound of stiffness or damping that makes the rate of the targeted energy term as favourable as possible, and since the contribution of a device to that rate depends only on its own stiffness and damping, the decision is taken device by device, with no coordination among the N devices.
The devices just introduced are viscoelastic: stiffness and damping act in parallel in each of them, and each of the two can be switched independently between an upper bound (superscript max) and a lower bound (superscript min). The choice follows from the control laws themselves. Since the laws modulate stiffness as well as damping, a device that offers both resources is required, whereas a purely viscous element would confine the framework to its damping laws. Two-state switching is adopted because the laws are sign-based, so that every device is assigned at each instant to one of its two bounds; in this study the lower bounds are set to zero, so that a device at its lower bound transmits no force to the deck. The idealization is representative of magnetorheological dampers, whose force–velocity characteristic is varied by an applied magnetic field [39,40,41,42,43,44], and of variable-stiffness devices built on the same principle, and it retains the property that motivates semi-active technology in the first place: in the event of a loss of power or control signal, the device reverts to a passive element. The study is not tied to a specific device technology, or to a particular force–velocity law beyond the two-state idealization; the features of real devices that this idealization leaves out are discussed in Section 6 and Section 7.
- -
- Maximization of Dissipated Energy:
This is the simplest law of the framework, because maximizing the dissipated energy requires no knowledge of the response: the power dissipated by device i is Cyi times the square of its own velocity, which cannot be negative, so it can only grow with Cyi, whatever the state of the system. Equation (5) therefore keeps every damping device at its maximum at all times, needs no on-line measurement, and coincides with the fully activated passive configuration, which makes it the natural benchmark for the other two laws.
- -
- Minimization of Elastic Energy:
In this law the damping of every device is held at its maximum, Equation (7), and only the stiffness is modulated. Equation (6) follows from the rate of change of the elastic energy stored in device i, which is , with ui = y + θ∙xKi and the displacement and the velocity of the device relative to the ground. Expanding the factors of Equation (6) returns exactly the product , multiplied by a positive factor that does not affect the sign, so that the condition reads . When displacement and velocity of the device have opposite signs, the device is moving back towards its undeformed position and its elastic energy is being released, and the maximum stiffness is selected to make the release as fast as possible; when they have the same sign, the elastic energy is growing, and the minimum stiffness limits the growth. Translation contributes to ui and in the same way at every device, whereas the rotational contribution is weighted by the position xKi and changes sign across the centre of the deck. Devices placed at different points of the deck therefore see different combinations of the two components and switch at different instants during the same response: this is how the law follows the lateral–torsional coupling of the system.
- -
- Minimization of Kinetic Energy:
The kinetic-energy law acts on the absolute velocity of the deck. Equations (8) and (9) reduce to the sign of the product between a local device quantity and the absolute velocity at the device location. When the product is non-negative, the device force opposes the absolute motion and removes kinetic energy, so the maximum stiffness or damping is selected; otherwise, the minimum value is used, so that no energy is transmitted to the deck.
A fourth law, aimed at minimizing the input energy, completes the framework [59] but is not considered in the present study.
3. Ground Motion Records and Structural Cases
For the numerical investigation, a total of 85 natural seismic records were selected, with their primary properties summarized in Table 1 and Table 2. These events were chosen for their high variability and can be categorized into two main groups [66]: 45 far-field (FF) and 40 near-fault (NF) seismic inputs. Each record is assigned a unique numerical label, from 1 to 85, for consistent reference throughout the study.
Table 1.
Considered far-field seismic records.
Table 2.
Considered near-fault seismic records.
Specifically, the far-field recordings are subdivided into three subsets based on their PGA/PGV ratio [66]: high ratio (HR, labels 1–15), medium ratio (MR, labels 16–30), and low ratio (LR, labels 31–45). In contrast, the near-fault records (labels 46–85) exhibit a markedly higher specific energy density (SED), with energy concentrated in the low-frequency range. This reflects the high energy content and the impulsive, pulse-type features characteristic of near-source ground motions [67,68]. These indices carry significant physical meaning: the PGA/PGV ratio is an effective parameter for characterizing the frequency content and duration of ground motions [69,70], while the SED captures the impulsive nature and energy concentration of seismic events, providing the most substantial information regarding structural response according to the Shannon entropy metric [71,72]. In addition to these signal descriptors, each record carries the EC8 soil classification of its recording site, distinguishing stiff (A), intermediate (B) and soft (C) soils; across the suite, 24 records fall on class A, 43 on class B and 18 on class C. Together, the far-field/near-fault character, the PGA/PGV ratio, the specific energy density and the soil class constitute the metadata along which controller effectiveness is disaggregated in the present study.
The records, drawn from a global strong-motion database, span the moment magnitudes and source-to-site distances representative of moderate-to-strong seismicity. Since the disaggregated assessment adopted here is based on the percentage reduction of each energy quantity relative to the uncontrolled response of the same structural case, defined in Section 4, instead of on absolute response levels, the analysis is intrinsically normalized on a record-by-record basis: every reduction is referred to the demand that the same record imposes on the same uncontrolled system, so that records of widely varying intensity become directly comparable without the need for a common spectral scaling. The records are therefore employed at their natural intensity, preserving the relative frequency content and energy severity that the disaggregation is designed to resolve.
Table 3 reports the joint distribution of the suite across the two categorical axes. It reveals a strong association between site class and record character: the class-A records are exclusively far-field and the class-C records exclusively near-fault, while only the intermediate class B spans both categories in comparable proportions. This association reflects geological and database factors rather than a causal link: active faults often bound sedimentary basins, so near-fault stations tend to lie on soft deposits, which also lengthen the period of the directivity pulses [73]. As a consequence, the two axes are partially confounded, and the disaggregated results must be read accordingly: differences between the stiff (A) and soft (C) groups reflect the combined influence of site conditions and impulsive character, whereas the class-B subset, which contains both far-field and near-fault records, allows the two effects to be partly separated.
Table 3.
Joint distribution of the 85-record suite by EC8 soil class and far-field/near-fault character.
The practical consequence is a limit on what the comparisons of Section 5 can claim. Contrasts between the stiff and soft groups, and between far-field and near-fault records over the whole suite, describe the signature of conditions that co-occur in this database; they do not establish what would persist if site or source were varied independently. The separation offered by class B rests on 21 far-field and 22 near-fault records, so any conclusion drawn from it carries the uncertainty of subsets of that size. The associations with the continuous descriptors, PGA/PGV and SED, are evaluated over the whole suite and are less exposed to the confounding, although a monotonic trend may still partly reflect the correlation of a descriptor with record type. Combinations absent from the suite, such as stiff-soil sites subjected to near-fault motion, lie outside what the present results support.
Unless otherwise stated, all results refer to the following reference case (RC), whose parameters are kept constant throughout the analyses. The deck is a single-storey system of rectangular plan with aspect ratio 2:1 and uniformly distributed mass, whose dimensionless mass radius of gyration is and structural stiffness radius of gyration λk = 1/2 − εkx, i.e., λk = 0.40 for εkx = 0.10, which corresponds to an uncoupled torsional-to-translational frequency ratio Ωθ = λk/λM ≅ 1.24, typical of torsionally stiff systems. The supplemental damping is provided by N = 5 identical devices located at x/l = −1/2, −1/4, 0, +1/4, +1/2, i.e., uniformly distributed over the plan, so that no additional eccentricity is introduced and the observed effects depend on the switching logic instead of on the device layout. The maximum supplemental stiffness and damping are defined by rK = 0.2 and ξy = 0.10, respectively, representing moderate supplemental resources. Switching is assumed instantaneous, and the intrinsic damping is 2% Rayleigh, calibrated on the first two natural frequencies of the uncontrolled system. The translational period is Ty = 1.0 s when a single value is required, and is varied between 0.1 and 2.0 s in steps of 0.1 s otherwise. When rK and ξy are varied, all other parameters remain those of the reference case.
4. Disaggregation Variables and Robustness Metrics
Solving the equations of motion of Section 2 for each structural case and each ground motion of the suite yields the time histories of the energy quantities entering the balance of Equation (4). From each history the peak value over the duration of the excitation is extracted, and it is on these peak energy demands that the present study operates. Rather than averaging them over the record suite, as is customary, the peaks are organized so as to expose how the effectiveness of each control law depends on the characteristics of the site and of the excitation. This section defines the effectiveness metric, the variables along which it is disaggregated, and the statistical descriptors used to quantify both its central level and its dispersion.
For a given structural case, control law and record j, let Ecrtl,j denote the peak over time of the elastic, Eel, kinetic, EK, or dissipated energy, Eξ, each evaluated under the control law targeting the same energy quantity, and let ENC,j denote the same peak evaluated for the uncontrolled system subjected to the same record. The effectiveness of the control law on record j is measured by the percentage variation of the peak energy demand relative to the uncontrolled case according to the specific algorithm objective:
A positive Rj indicates that, with respect to the uncontrolled configuration, the control law lowers the peak of the targeted quantity in the case of elastic and kinetic energy, and increases it in the case of dissipated energy, so that a positive value always denotes a beneficial effect. The variation is evaluated record by record, so that its distribution over the suite, and not merely its average, becomes accessible to analysis. Because Rj is a dimensionless ratio referred to the uncontrolled response of the same case, it is directly comparable across periods, eccentricities and records, which is what makes the subsequent disaggregation meaningful.
The record-wise variation Rj are grouped along three engineering-relevant axes, chosen because they are known to govern the seismic demand on asymmetric systems and are available as metadata for every record of the suite:
- -
- Site class: EC8 soil class of the recording site, stiff (A), intermediate (B) or soft (C);
- -
- Record character: Far-field or near-fault;
- -
- Signal descriptors: PGA/PGV ratio and specific energy density (SED). The two signal descriptors serve as proxies for the dominant frequency content and the energy severity of the record, respectively; being continuous, they allow a correlation analysis that does not require binning.
The first two axes partition the 85-record suite as summarized in Table 1 and Table 2, whereas the third treats the descriptors as continuous variables. Together they resolve the effectiveness of each control law along the dimensions that aggregate, suite-averaged reporting necessarily conceals.
Within each group, the effectiveness of a control law is described not by a single number but by the distribution of the reductions Rj across the records of the group. A strategy that lowers the demand strongly on average but erratically across records is, for design purposes, less desirable than one that lowers it consistently: the dispersion of the reduction is therefore treated as a quantity of interest in its own right, on the same footing as its central level. For a group containing n records, the following descriptors are reported:
- -
- Central level: The median reduction, , is adopted as the measure of central tendency in preference to the mean, being robust to the occasional outlying record that the near-fault subset in particular can produce:
- -
- Dispersion: The spread of the reductions is quantified by the interquartile range, delimited by the 25th and 75th percentiles (R25, R75), and by the coefficient of variation, defined as the ratio of the standard deviation, σR, to the mean of the reductions, μR:
IQR = R75 − R25
COV = σR/μR
The interquartile range measures the spread in the same units as the reduction (percentage points) and is insensitive to the tails of the distribution, whereas the coefficient of variation provides a scale-free measure of relative dispersion that allows the robustness of different strategies, or of the same strategy on different groups, to be compared directly.
- -
- Signal dependence: The association between the achieved reduction and each continuous signal descriptor is quantified by the Spearman rank correlation coefficient ρ, computed across the records at a fixed structural case
These descriptors are applied uniformly to the elastic-, kinetic- and dissipated-energy laws in the following sections. Together, the reduction of Equation (10), its distribution summarized through Equations (11)–(13) and the rank correlations of Equation (14) constitute the methodological core of the analysis: they turn the raw energy demands of the framework into a site- and signal-resolved, robustness-aware characterization of controller effectiveness.
5. Results and Discussion
The disaggregated assessment defined in Section 4 is now applied to the elastic-, kinetic- and dissipated-energy control laws. Unless otherwise stated, the results refer to the reference case defined in Section 3, characterized by a strongly coupled lateral–torsional behaviour (εkx = 0.10). For brevity, the detailed disaggregated results are reported for the elastic-energy law only, which, as shown in Section 6, is the strategy selected over most of the examined parameter space and therefore the reference case for the assessment. The kinetic- and dissipated-energy laws are characterized through the rank correlation of their reduction with the PGA/PGV ratio and with the specific energy density, which is sufficient to identify their distinct sensitivity to the signal characteristics.
All results reported below are the end product of a time-history analysis, which constitutes the first step of the procedure and is common to every case examined. For each structural configuration and each record of the suite, the coupled equations of motion, Equation (3), are integrated under the recorded ground motion, both for the uncontrolled system and for the system governed by each control law, yielding the complete histories of the two degrees of freedom, of the edge displacements derived from them, and of the five energy quantities of the balance, Equation (4). From each history the peak value of the targeted energy quantity is extracted and converted into the percentage reduction of Equation (10), the elastic-energy reduction under the elastic-energy law, the kinetic-energy reduction under the kinetic-energy law, and so forth, so that every strategy is judged on the energy quantity it is designed to control. The aggregate and disaggregated descriptors of the following subsections are computed on these record-wise peaks; the time-history stage is therefore performed 85 times for each structural configuration. Two records are selected to represent this first analytical step and to span the two extremes of the suite: a severe far-field event on stiff soil (record no. 8, San Fernando–Pacoima Dam, EC8 class A) and a high-demand near-fault event on soft soil (record no. 64, Northridge–Sylmar Converter Station, EC8 class C). Their controlled and uncontrolled responses are examined in the time domain in Figure 2, Figure 3, Figure 4 and Figure 5, which document that the reductions quantified statistically in the remainder of the section rest on a physically consistent instantaneous behaviour and expose the different manner in which the control laws operate under broadband and impulsive demand.
Figure 2.
Elastic energy time histories, no-control vs. elastic-energy law, records n.8 (a) and n.64 (b).
Figure 3.
Dissipated energy time histories, no-control vs. elastic-energy law, records n.8 (a) and n.64 (b).
Figure 4.
Kinetic energy time histories, no-control vs. elastic-energy law, records n.8 (a) and n.64 (b).
Figure 5.
Flexible-edge displacement time histories, no-control vs. elastic-energy law, records n.8 (a) and n.64 (b).
Figure 2, Figure 3 and Figure 4 report the time histories of the three energy quantities of the balance in Equation (4): elastic, dissipated and kinetic, respectively, for the uncontrolled system and for the system governed by the elastic-energy law, on the two representative records introduced above. A single strategy, the elastic-energy law, is active in all of them: together, the figures show not only how the targeted elastic energy is lowered, but also the concurrent effect that the same law exerts on the kinetic and dissipated components, which it does not directly control. The comparison of the controlled and uncontrolled histories shows that the reduction of the elastic energy is sustained throughout the response, and not confined to its peak, while the contrast between the far-field and near-fault panels illustrates the concentrated, pulse-driven build-up of demand characteristic of the near-source input.
Since in the reference case (RC) the normalized stiffness eccentricity εkx = 0.10 places the centre of stiffness on the positive side of the centre of mass, the flexible edge lies at x = −l/2. Figure 5 shows the corresponding time histories of its displacement:
for the uncontrolled and controlled systems. The flexible edge is chosen because it experiences the largest demand in a plan-asymmetric system; the reduction of its peak and of its sustained amplitude is the displacement-level counterpart of the energy reductions quantified statistically in the remainder of the section.
The responses of Figure 2, Figure 3, Figure 4 and Figure 5 are the outcome of a switching activity that can be read directly from the devices. Figure 6 reports, for the same two records, the stiffness state of the central device (x/l = 0) under the elastic- and kinetic-energy laws, reconstructed from the computed time histories through the closed-form conditions of Equations (6) and (8).
Figure 6.
Stiffness-switching activity of the central device (x/l = 0) in the reference case: (a,b) flexible-edge displacement under the elastic-energy and the kinetic-energy laws; (c,d) stiffness state of the device under the elastic-energy law; (e,f) stiffness state under the kinetic-energy law.
Under the elastic-energy law, the device commutes about 3.5 times per second on the far-field record no. 8, against 1.8 times per second on the near-fault record no. 64, a reduction of nearly one half, while it spends about half of the response at maximum stiffness in both cases. The kinetic-energy law commutes its stiffness 2.0 and 1.8 times per second on the two records, so that the contrast between far-field and near-fault input is much weaker than for the elastic law. Its damping, Equation (9), is a different matter: it stays at its maximum for more than 95% of the response on both records, and the rate of its commutations, measured at the device at x/l = 1/2, rises from 0.84 to 1.15 per second on passing to the near-fault record. Read together with Table 4, these figures suggest a mechanical reason for the lower relative effectiveness of the elastic-energy law under impulsive input. The stiffness decision is renewed each time the product changes sign, that is, at the displacement peaks and at the zero crossings of the device. A velocity pulse gathers the input energy in one or two large excursions of the deck, and the demand is built up before many such reversals have occurred; the law has few occasions to intervene while the relevant energy is accumulating. On a broadband far-field record, the same accumulation is spread over many cycles, each of which offers a further opportunity of correction. The data of Figure 6 are consistent with this reading, which is put forward as an interpretation of the observed behaviour and not as a demonstrated mechanism.
Table 4.
Elastic-energy reduction–robustness statistics at the reference case (εkx = 0.10, Ty = 1.0 s, rK = 0.2).
Beyond the illustrative time-history response, the disaggregated statistics attribute the achieved reduction to its determinants, beginning with the dependence on site conditions. Because the reduction Rj depends on the structural case, its median is in general a function of the translational period Ty for any fixed eccentricity, damping and stiffness ratio, Figure 7 reports this function, together with the mean, shown for comparison, for the elastic energy under the elastic-energy law, disaggregated by EC8 soil class. The corresponding robustness statistics at the reference period are collected in Table 4.
Figure 7.
Spectrum of the elastic energy reduction coefficient for different soil types.
The effectiveness is comparable on stiff (A) and intermediate (B) sites and appreciably lower on soft (C) sites: the median reduction is 62.3% on class A and 61.4% on class B, but falls to 50.4% on class C. The degradation on soft soils is consistent with their low-frequency amplification, which shifts the demand toward the spectral region where a stiffness-based control law has least leverage. This dependence is invisible to a suite-averaged descriptor, which would report an intermediate effectiveness that no single site actually experiences and would, in particular, overstate the protection available on the soft-soil sites often most critical for asymmetric buildings.
This reading must, however, be qualified by the confounding documented in Table 3: in the present suite the class-A records are exclusively far-field and the class-C records exclusively near-fault. The contrast between the stiff and soft groups therefore reflects the combined variation of site conditions and impulsive character, and cannot be attributed to soil class alone. Only the intermediate class B, which contains both far-field and near-fault records in comparable proportions, permits the two effects to be examined in partial isolation; the far-field/near-fault comparison of the next subsection addresses this directly.
As a consequence, the lower reduction recorded on class C in Table 4 cannot, on the evidence of this suite, be apportioned between a soil contribution and a record-type contribution: it is to be read as the combined signature of soft-soil and near-fault conditions. Within class B, where the two record types coexist, the median reduction of the elastic-energy law is 68.8% on the 21 far-field records and 53.0% on the 22 near-fault records (Mann–Whitney p = 0.14). The gap of about 16 points is of the same size as the one found over the whole suite (65.1% against 51.7%, Table 4), which indicates that most of the difference is associated with the record type and not with the soil. For the kinetic-energy law, the same comparison gives 49.0% against −27.6% (p = 0.001). With 21 and 22 records, the comparison remains indicative and not conclusive.
Figure 8 contrasts the reduction achieved on the far-field and near-fault subsets for the elastic- (a) and kinetic-energy (b) laws. Both strategies are less effective under near-fault excitation: for the elastic-energy law the median reduction falls from 65.1% on far-field records to 51.7% on near-fault records (Table 4).
The finding refines, and in part tempers, the picture offered by the base study, whose aggregate reporting emphasized the benefit of the proposed laws under high-demand near-fault events. When effectiveness is measured as reduction relative to the uncontrolled demand and examined within the near-fault group, the impulsive records emerge as the more adverse scenario for these stiffness-based strategies: the velocity pulse imposes a concentrated demand that the instantaneous switching law, tuned to the ongoing kinematic state, cannot anticipate, as the lower switching rate recorded on the near-fault record in Figure 6 suggests. The two statements are not contradictory: the controlled near-fault response can still be lower in absolute terms than the far-field one, but the relative protection afforded is smaller, which is the quantity of interest when sizing a control system to a target performance.
A further insight into the dependence of the control laws on ground-motion characteristics is obtained by examining their correlation with continuous signal descriptors, rather than with the discrete classifications already considered. The dependence of each control law on the ground-motion characteristics is quantified in Table 5 through the Spearman rank correlation, Equation (14), between the record-wise reduction and the two continuous signal descriptors, PGA/PGV and specific energy density, evaluated at the reference case.
The three laws display distinct behaviours. The kinetic-energy law is strongly and positively correlated with PGA/PGV: its effectiveness increases with the high-frequency content of the excitation, and it declines markedly on the energetically severe records. The dissipated-energy law follows the same trend as the kinetic-energy law, in a much weaker form: a mild positive correlation with PGA/PGV (ρ = 0.32) and a mild negative correlation with SED (ρ = −0.34), so that the gain in dissipated energy it provides is somewhat larger on high-frequency records and somewhat smaller on the energetically severe ones. The elastic-energy law, by contrast, is essentially uncorrelated with either descriptor (|ρ| ≤ 0.03): its effectiveness does not vary monotonically with the frequency content or the energy severity of the record. This does not make it independent of the excitation, since its median reduction is lower on near-fault and soft-soil records (Table 4); the residual dependence is therefore associated with the impulsive character of the input rather than with the scalar indicators considered here. Figure 9 displays the underlying scatter of the record-wise reductions against the two descriptors.
Figure 8.
Median reduction far-field vs. near-fault records: (a) elastic energy, (b) kinetic energy (εkx = 0.10, rK = 0.2).
Figure 9.
Scatter of record-wise reduction [%] vs. PGA/PGV (a) and SED (b) at Ty = 1.0 s—Far field vs. Near Fault.
Table 5.
Spearman rank correlations between the record-wise reduction and the signal descriptors, at the reference case.
The contrast between the three rows of Table 5 provides a significant design insight. It demonstrates that the selection of a control law is not a matter of identifying a universally superior strategy, but rather of tailoring the law to the expected ground motion. Specifically, the kinetic-energy law is the one whose effectiveness is most closely tied to the frequency content, and it is preferable when the anticipated seismic demand is characterized by high-frequency, moderate-energy motions. The dissipated-energy law shows the same tendency in a much weaker form, so that Table 5 gives no ground for preferring it on energetically severe inputs. In this context, the elastic-energy law serves a distinct purpose, providing a reduction that is stable with respect to PGA/PGV and SED, its level being mainly determined by the supplemental stiffness available.
The dispersion statistics in Table 4 show that the reduction, though substantial, is far from uniform across records. Coefficients of variation of the order of 0.45, and of 0.48 for the near-fault subset, indicate that the reduction obtained on an individual record may depart materially from the group median, so that the median overstates the protection that can be relied upon on the less favourable records. The interquartile ranges tell the same story in absolute terms: spanning roughly thirty to forty percentage points, they are widest for the near-fault group, indicating that, for impulsive excitations, the reduction is lower on average and also more variable. Figure 10 displays these distributions as box plots by group. For design, this dispersion is itself the primary quantity: a control system sized to a target reduction should be verified against the lower quartile of the relevant group rather than against its median, particularly for near-fault-dominated sites.
Figure 10.
Distribution of the elastic-energy reduction by group (soil class and record type) at Ty = 1.0 s. The symbol * indicates outliers.
6. Algorithm Selection Maps
The statistics of Section 5 describe how effectively each law lowers the energy it is designed to control. A designer, however, does not select a controller through an energy budget but through the response it delivers, and must do so before the ground motion is known, on the basis of the site, the expected type of excitation and the semi-active resources that can be installed. This section condenses the disaggregated analysis into algorithm-selection maps that answer that question directly: for a given site condition, translational period and amount of supplemental stiffness and damping, which of the three laws leaves the lowest edge displacement. The maps are conceived as a design tool, to be read as a first indication of the strategy to adopt, and their physical consistency is examined before their use is discussed.
The energy reductions of Equation (10) cannot be used to rank the three laws against one another. The elastic- and kinetic-energy laws minimize the quantity they target whereas the dissipated-energy law maximizes it, so the three targets are in any case not commensurable. The ranking is therefore based on a quantity that is the common objective of all strategies, the peak edge displacement:
that is, the largest displacement attained over the response by either edge of the deck.
For every combination of the structural characteristics, namely the translational period Ty and the eccentricity εkx, and of the semi-active resources made available by the controller, namely the stiffness ratio rK and the equivalent damping ratio ξy, and for every record, ymax is computed through time-history analyses under the three control laws. Within each group of records (soil classes A, B and C, far-field and near-fault), the median and the coefficient of variation CoV(ymax) are computed, and each cell of a map is assigned to the law with the lowest median.
Figure 11 reports ymax for the individual records at Ty = 1.0 s, separately for the three soil classes. The data reveals a clear progression of demand from stiff to soft sites, scaling from 0.2 m (class A) to 0.4 m (class B) and 0.5 m (class C), while the distinction between far-field (below 0.1 m) and near-fault (0.37 m) records in class B highlights the dominance of impulsive input over soil classification. This is complemented by a strongly skewed distribution in class A, where nearly all records except numbers 8 and 10 present maximum edge displacement under 0.05 m. Additionally, the dissipated-energy law produces the highest displacements in almost all cases, exemplified by records 8 and 59. Although the elastic and kinetic laws are mostly similar, they exhibit discrepancies of 15–40% in specific instances, with the kinetic law being lower on records 57, 59, and 66 (class B) and the elastic law being lower on records 24 (class A) and 67 (class C).
Figure 11.
Peak edge displacement ymax of the individual records at Ty = 1.0 s: (a) soil A, (b) soil B, (c) soil C—reference case.
Figure 12 reports the median as a function of Ty. For all classes the median grows almost linearly with the period, from a few millimetres to about 0.04–0.06 m (A), 0.09–0.11 m (B) and 0.27–0.37 m (C), and the ordering A < B < C holds at every period. The dissipated-energy law is the upper envelope of the three curves, and at Ty = 1.0 sec it exceeds the elastic law by roughly 25–30% on all classes. The elastic and kinetic curves are hardly distinguishable up to such a period value; beyond that, the kinetic law is lower on classes A and C, by up to about 10%, whereas on class B the elastic law is marginally better at the longest periods.
Figure 12.
Median peak edge displacement vs. structural period for the reference structure: (a) soil A, (b) soil B, (c) soil C.
The dispersion of ymax, shown in Figure 13 in terms of CoV, is of order one on classes A and B, and much lower on class C. This quantity measures the heterogeneity of the demand within a group, since the records are employed at their natural intensity, rather than the quality of the controller: class C is the most homogeneous group, being entirely near-fault, whereas classes A and B mix records whose energy content differs by orders of magnitude (Table 1 and Table 2), and the large values in class A are driven by the two outliers seen in Figure 10. It differs, therefore, from the CoV of the reduction used in Table 4, and it is meaningful mainly as a comparison between strategies inside the same group. In that comparison the differences are small; the kinetic law has the lowest dispersion on class B over most of the range 1.0–1.6 s, but the highest on class C at Ty = 1.2 − 1.8 s. On the soft, impulsive sites, the modest gain in median displacement of the kinetic law is thus accompanied by a slightly less predictable outcome.
Figure 13.
Coefficient of variation CoV(ymax) vs. structural period for the reference structure: (a) soil A, (b) soil B, (c) soil C.
The numerical analyses conducted enable the most suitable algorithm among those considered to be identified as a function of the mechanical characteristics of the system to be protected. Figure 14 illustrates this result for the reference structure, identifying, for each record group and translational period, the law associated with the lowest median edge displacement at the reference resources.
Figure 14.
Algorithm-selection map for the—reference case.
The dissipated-energy law is never selected, in agreement with Figure 12, whereas at short and intermediate periods, the map is fragmented, with cells alternating between the elastic and kinetic laws. This reflects their near-equivalence rather than a sensitivity of the physical response: since the medians differ by only a few percent, small changes in the record set are enough to reverse their ranking, and isolated cells should be read as ties. The pattern becomes systematic in two situations. On soft soil (class C), the elastic law is selected for Ty ≤ 0.3 s and the kinetic law for the remaining periods; in the case of near-fault records, the kinetic law is selected for every Ty ≥ 0.5 s, with the sole exception of Ty = 0.7 s. The two rows are, in effect, two readings of the same finding, since class C is entirely near-fault and the near-fault row is dominated by class B and C records (Table 3). The kinetic law also prevails at the longest periods on class A and on far-field records, while on class B, where both record types coexist, the elastic law reappears from Ty = 1.6 s.
A physical reading is that the kinetic law acts on the absolute velocity, which is dominated by the velocity pulse of near-fault records, and a pulse period of the order of one to a few seconds [67,68] is close to the period of the flexible systems for which the kinetic law prevails.
The proximity can be given a measurable form with the frequency-content descriptor already used in Section 3. Since PGA/PGV has the dimension of an inverse time, T* = 2π/(PGA/PGV) provides an estimate of the dominant period of a record. Set against Figure 14, the ordering is consistent: ranking the five groups by their median T*, the translational period from which the kinetic law prevails decreases monotonically, from 1.7 s on class A (T* = 0.57 s) and 1.6 s on far-field records (T* = 0.62 s) to 0.9 s on class B (T* = 0.94 s), 0.5 s on near-fault records (T* = 1.34 s) and 0.4 s on class C (T* = 1.40 s). The kinetic region therefore opens at the shortest translational periods for the groups whose input is richest in long periods. The relation is one of ordering and not of coincidence: the onset is close to T* only on class B, it lies well below it on class C and on near-fault records (Ty/T* ≅ 0.3–0.4) and above it on class A and on far-field records (Ty/T* ≅ 3). Since T* is a coarse descriptor of a record that contains a broad band of periods, and the five groups share records, the result should be read as an association and not as a threshold.
At short periods, by contrast, the structure follows the ground motion almost quasi-statically and the switching action has little leverage, so that the two laws are practically equivalent. This does not contradict Table 5, where the kinetic law is found to be less effective in terms of kinetic-energy reduction on the energetic records: it refers to the percentage reduction of the law’s own energy with respect to the uncontrolled system, whereas the maps rank the laws against each other on displacement.
Figure 15 shows how the map changes when the resources are varied with respect to the reference values: (a) rK = 0.1 and ξy = 0.3, (b) rK = 0.1 and ξy = 0.5, (c) rK = 0.2 and ξy = 0.2, (d) rK = 0.3 and ξy = 0.3. These combinations span different balances between the two resources, from damping-dominated configurations with low additional stiffness, (a) and (b), to configurations in which stiffness and damping are increased together, (c) and (d).
Figure 15.
Algorithm-selection maps for different supplemental resources: (a) rK = 0.1 and ξy = 0.3, (b) rK = 0.1 and ξy = 0.5, (c) rK = 0.2 and ξy = 0.2, (d) rK = 0.3 and ξy = 0.3. Colours as in the legend of Figure 14.
The main effect is that of the damping: doubling ξy from 0.1 to 0.2 at the reference rK removes almost all the kinetic regions (panel c, where only class C at Ty = 0.8 s and the near-fault row at Ty = 1.4–1.8 s remain), and for ξy ≥ 0.3 (panels a, b, d), the kinetic law is never selected. In the four panels the elastic law is selected in over 90% of the cells. The few cells assigned to the dissipated-energy law occur at Ty = 0.1 s, where the displacements are millimetric and the three laws are indistinguishable, or, in panel (b), as scattered isolated cells. In that panel the supplemental stiffness is small with respect to the damping, so that the elastic law, which keeps the damping at its maximum, has little stiffness authority and approaches the damping-only solution; that is, the green cells are ties and do not indicate a preference for the dissipated-energy law.
The results clearly show that the selection of the optimal algorithm depends on the stiffness and damping resources available to the semi-active control system. This dependence motivates a further parametric analysis in which three representative values of Ty are considered, namely 0.3, 1.0 and 2.0 s, and, for each soil class, the optimal algorithm is investigated as a function of the available stiffness and damping resources, represented by rK and ξy, respectively. Figure 16, Figure 17 and Figure 18 present the results of such analysis, with the semi-active resources used as the axes: each panel spans rK and ξy from 0.05 to 0.50 for one soil class. All nine panels share a common structure: the elastic law occupies the upper part, the kinetic law a band along the bottom (low ξy) whose thickness depends on rK, Ty and soil, and the dissipated-energy law only a few isolated regions.
Figure 16.
Best-algorithm maps in the (rK, ξy) plane—Ty = 1.0 s, εkx = 0.1—(a) Soil A; (b) Soil B; (c) Soil C.
Figure 17.
Best-algorithm maps in the (rK, ξy) plane—Ty = 0.3 s, εkx = 0.1—(a) Soil A; (b) Soil B; (c) Soil C. Colours as in the legend of Figure 16.
Figure 18.
Best-algorithm maps in the (rK, ξy) plane—Ty = 2.0 s, εkx = 0.1—(a) Soil A; (b) Soil B; (c) Soil C. Colours as in the legend of Figure 16.
At Ty = 1.0 s (Figure 16), the kinetic band is thinnest in class A, extending up to ξy = 0.05 for rK ≤ 0.20, to 0.10 for rK = 0.25 − 0.40 and to 0.15 for rK ≥ 0.45, it is slightly thicker on class B, and thickest on class C. At Ty = 2.0 s (Figure 18), the band on class C is flat, with an upper limit near ξy = 0.10–0.12 independent of rK, and on class A it stays within ξy = 0.10–0.15. The only region in which the dissipated-energy law is selected over a compact area appears on class C at Ty = 0.3 s (Figure 17c), for large stiffness and damping ratios, smaller regions occur on class B at Ty = 0.3 s and 1.0 s at the corners of the plane, and a single cell in class A at Ty = 1.0 s.
The relative behaviour of the three control laws reveals further features of interest. The dissipated-energy law produces displacements that are about 25–30% larger than those of the elastic law at the reference resources. Since the two laws maintain the same maximum damping, according to Equations (5) and (7), their difference is primarily associated with the stiffness modulation introduced by the elastic-energy formulation in Equation (6). The results thus indicate that stiffness switching has a non-negligible influence on the response. The kinetic law shows a different dependence on ξy. In this case, the damping is switched between its maximum and minimum values, as described by Equation (9), so that increasing the available damping also increases the amount of dissipation lost when the damping is reduced. This behaviour is reflected in the progressive reduction of the kinetic region as ξy increases, until it disappears for ξy ≥ 0.2–0.3 in Figure 15, Figure 16, Figure 17 and Figure 18. The widening of the kinetic band with increasing rK in Figure 16 and Figure 17 points in the same direction, highlighting the increasing role of stiffness modulation as more stiffness becomes available.
Some features of the maps, however, should be regarded as interpretations rather than as established mechanisms. In particular, the preference for the dissipated-energy law at Ty = 0.3 s on class C for large resource levels, as well as the observed dependence on rK, would benefit from a more direct analysis of the switching activity at those periods, since the analysis of Figure 6 refers to Ty = 1.0 s. One possible interpretation of the short-period behaviour is that, in a stiff system with large rK, abrupt stiffness changes at non-zero displacement may introduce additional energy into the response, partly offsetting the benefit associated with stiffness modulation. This interpretation remains to be verified through an examination of the actual switching sequences.
The maps assume devices that react without delay, and the question is how much of the ranking of the laws survives a realistic response time. To quantify it, the equations of motion were integrated again with a delay τ applied to the switching decisions of every device, for τ = 10, 25 and 50 ms, over the whole range of translational periods, for the two representative records of Section 5 and at the reference resources. This scheme reproduces the peak edge displacement of the main model within about 10% of the reference case, and every change below is expressed relative to the same scheme without delay. Figure 19 shows the increase in the peak edge displacement caused by τ = 50 ms. The effect is concentrated at short translational periods and on the elastic-energy law: on the far-field record no. 8 the peak displacement grows by 15% at Ty = 0.2 s, 7% at 0.4 s and 11% at 0.6 s, and on the near-fault record no. 64 by 13% at 0.2 s and 8% at 0.4 s. From Ty = 0.8 s upwards, the increase does not exceed 4% on either record, in agreement with the faster switching of stiffer systems. The kinetic-energy law is hardly penalised: its peak displacement changes between −9% and +2% on record no. 8 and between −4% and +2% on record no. 64, the reductions being a consequence of the particular phasing between delayed switching and response and not of any systematic benefit. Delays of 10 and 25 ms produce smaller changes. Since the medians of the two laws differ by a few percent over a large part of the maps, a delay of this size could exchange the ranking in cells that are already ties, whereas the regions in which one law prevails by about 10% would be expected to stand, with the exception of the elastic-energy law at the shortest periods, where a delay of 50 ms may remove its advantage.
Figure 19.
Increase of the peak edge displacement caused by an actuation delay as a function of the translational period: (a) elastic-energy law; (b) kinetic-energy law.
A practical question remains, namely, how the maps translate into a guide for selecting the control law for a given structural configuration and expected seismic demand. The maps can be used as a screening tool by first identifying the group of records that best represents the expected seismic demand, based on the soil class and, where relevant, on the far-field or near-fault character of the input, together with the translational period of the structure. The available supplemental resources can then be located in terms of rK and ξy, and the corresponding region of the maps can be used to identify the control law associated with those resources. Viewed in this way, the maps provide some practical indications on the different roles of the three laws. The elastic-energy law is selected, or is essentially tied with another law, over a large portion of the parameter space. Its main feature is that it maintains the damping at its maximum value throughout the response, while its relative effectiveness is uncorrelated with PGA/PGV and SED (Table 5). This makes it a particularly straightforward option when the control law has to be selected before the earthquake and the characteristics of the actual input are uncertain. The kinetic-energy law becomes more competitive for flexible systems subjected to soft-site or impulsive motions, particularly for class C and near-fault records, with Ty ≥ 0.4–0.8 s, modest supplemental damping, ξy ≤ 0.10–0.15, and a substantial available stiffness resource. In these conditions, the reduction in median displacement relative to the elastic law remains limited, reaching about 10% at most, and is accompanied by a somewhat larger dispersion on class C. Its potential benefit therefore has to be considered together with the additional complexity associated with switching both stiffness and damping. The dissipated-energy relative advantage is confined to the isolated regimes discussed above, where the difference is small, while it can still be regarded as a useful benchmark for a damping-only solution, for example when semi-active stiffness control is not available.
The damping axis also highlights a broader trend. Once ξy exceeds approximately 0.2, the selection becomes much less sensitive to both site class and period. In this range, sufficiently large supplemental damping tends to reduce the dependence of the preferred law on the characteristics of the expected ground motion.
7. Conclusions
The present study has evaluated the effectiveness of a closed-form, energy-driven semi-active control framework for viscoelastic devices in one-way plan-asymmetric systems, shifting the focus from aggregate performance metrics to a disaggregated, site- and signal-resolved assessment. Using a suite of 85 far-field and near-fault ground-motion records, the elastic-energy, kinetic-energy and dissipated-energy algorithms were evaluated across a wide range of translational periods and structural eccentricities. Effectiveness was quantified not only through conventional peak and mean energy demands, but also through robustness-oriented metrics and rank correlations with two signal descriptors. The resulting evidence was finally condensed into algorithm-selection maps that identify, for each combination of translational period, soil class and available supplemental resources, the control law that yields the lowest median peak edge displacement. The main conclusions can be summarized as follows:
- •
- The three energy-based laws exhibit markedly different sensitivities to the characteristics of the excitation. The kinetic-energy algorithm is strongly governed by the frequency content of the ground motion: its effectiveness increases systematically with the PGA/PGV ratio and declines on energetically severe records. In contrast, the elastic-energy algorithm is essentially uncorrelated with both PGA/PGV and specific energy density; its performance is controlled primarily by the structural properties and by the amount of supplemental stiffness that can be mobilized. The dissipated-energy law occupies an intermediate position, with the same signs as the kinetic-energy law but weaker correlations: mildly positive with PGA/PGV and mildly negative with the specific energy density. These distinct behaviours demonstrate that no single control law is universally superior: the kinetic- and elastic-energy laws, in particular, suit different classes of expected demand.
- •
- Both the elastic- and kinetic-energy strategies are appreciably less effective, in relative terms, on soft-soil (EC8 class C) and near-fault records. Median reductions fall by roughly ten to thirteen percentage points when moving from stiff or intermediate sites to soft soils, and from far-field to near-fault excitation. This reduction cannot be detected from suite-averaged results and is relevant in practice, since soft-soil and near-fault conditions impose the largest absolute demand on plan-asymmetric systems. The finding refines earlier aggregate results by showing that, while the controlled response may still be lower in absolute terms under impulsive or soft-soil input, the relative protection afforded by the control laws is reduced.
- •
- The reduction achieved by any of the strategies is far from uniform across records. Coefficients of variation of the order of 0.45–0.48, together with interquartile ranges spanning thirty to forty percentage points, indicate that the median overstates the protection that can be relied upon on the less favourable records. For design purposes, therefore, a control system sized to a target reduction should be verified against the lower quartile of the relevant record group rather than against its median, particularly for sites expected to experience near-fault or soft-soil ground motions.
- •
- The algorithm-selection maps translate the foregoing analytical evidence into a practical decision tool. Across most of the examined parameter space, the elastic-energy law is either preferred or essentially equivalent to the alternatives. Its stability with respect to the scalar signal indicators and the fact that it maintains damping at its maximum value throughout the response make it a robust default choice when the characteristics of the incoming motion are uncertain. The kinetic-energy law becomes competitive for flexible systems subjected to soft-site or impulsive demand, provided that supplemental damping remains modest and a substantial stiffness resource is available. Once the equivalent damping ratio exceeds approximately 0.2, the selection becomes largely insensitive to both soil class and period, indicating that sufficiently large supplemental damping reduces the dependence of the preferred law on the expected ground motion. The dissipated-energy law is rarely selected and serves mainly as a useful benchmark for a damping-only solution.
These conclusions are subject to the limitations of the underlying model. The investigation is confined to a single-storey, one-way asymmetric system, and the records are employed at their natural intensity. All class-A records are far-field and all class-C records are near-fault, so that conclusions on soil class alone rest on the class-B records only (Section 3 and Section 5); the findings on the signal descriptors are less exposed to this limitation.
Two idealizations also limit the reach of the maps. Switching is taken as instantaneous; the test of Section 6 shows that a delay of 50 ms alters the peak edge displacement appreciably only for the elastic-energy law on short-period systems, on both far-field and near-fault input, and little elsewhere, whereas force saturation and hysteresis of real devices, left out of the model, call for dedicated modelling and experimental validation. The structure, in turn, is assumed to respond linearly: Equation (3) keeps stiffness and damping constant, which rules out yielding of the lateral resisting members and second-order effects. The switching conditions of Equations (6), (8) and (9) are written in kinematic quantities only and remain formally applicable to a yielding structure, but their energetic meaning does not carry over unchanged. Once members yield, the energy balance of Equation (4) acquires a hysteretic dissipation term, the elastic energy is only the recoverable part of what is stored, and the stiffness the devices are meant to complement is no longer constant, so that the period on which the maps are indexed and the ratio rK drift during the response. The reductions reported here should therefore not be carried into the nonlinear range without further analysis.
The two idealizations just discussed define the first directions for further work. The transition to the nonlinear range comes first, so that the algorithms can be assessed under large deformations and damage accumulation, together with the incorporation of realistic device dynamics, namely hysteresis and force saturation in addition to the finite response time examined here, ideally supported by experimental validation of magnetorheological or variable-stiffness devices on reduced-scale specimens. The scope of the study can then be widened to multi-storey and two-way asymmetric configurations, which bring higher-mode effects and more complex edge-demand patterns. Beyond these, multi-objective formulations of the control laws (simultaneously targeting drifts, accelerations and residual displacements), optimized device placement, and larger or probabilistically stratified record suites, able to reduce the residual confounding and to refine the selection maps, offer further opportunities.
Until these extensions are available, the selection maps already serve as a working guide at the preliminary design stage: given the site class and the impulsive character of the expected input, they indicate which energy-based law to adopt, and what spread of reduction to expect from it.
Author Contributions
M.D.I.: conceptualization, methodology, software, validation, formal analysis, investigation, data curation, writing—original draft preparation, writing—review and editing, visualization. D.G.: methodology, investigation, formal analysis, writing—review and editing. E.M.: software, formal analysis, investigation, data curation, writing—review and editing. P.C.: supervision. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
The data supporting the findings of this study are available from the corresponding author upon reasonable and justified request.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Mansoori, M.R.; Moghadam, A.S. Using Viscous Damper Distribution to Reduce Multiple Seismic Responses of Asymmetric Structures. J. Constr. Steel Res. 2009, 65, 2176–2185. [Google Scholar] [CrossRef] [Scilit]
- Alam, Z.; Sun, L.; Zhang, C.; Su, Z.; Samali, B. Experimental and Numerical Investigation on the Complex Behaviour of the Localised Seismic Response in a Multi-Storey Plan-Asymmetric Structure. Struct. Infrastruct. Eng. 2021, 17, 86–102. [Google Scholar] [CrossRef] [Scilit]
- Esteva, L. Earthquake Engineering Research and Practice in Mexico after the 1985 Earthquakes. Bull. N. Z. Soc. Earthq. Eng. 1987, 20, 159–200. [Google Scholar] [CrossRef] [Scilit]
- Yoshida, O.; Dyke, S.J. Response Control of Full-Scale Irregular Buildings Using Magnetorheological Dampers. J. Struct. Eng. 2005, 131, 734–742. [Google Scholar] [CrossRef] [Scilit]
- Ozturk, M.; Arslan, M.H.; Korkmaz, H.H. Effect on RC Buildings of 6 February 2023 Turkey Earthquake Doublets and New Doctrines for Seismic Design. Eng. Fail. Anal. 2023, 153, 107521. [Google Scholar] [CrossRef] [Scilit]
- Siringoringo, D.M.; Fujino, Y. Seismic Response Analyses of an Asymmetric Base-Isolated Building during the 2011 Great East Japan (Tohoku) Earthquake. Struct. Control Health Monit. 2015, 22, 71–90. [Google Scholar] [CrossRef] [Scilit]
- Zhang, C.; Alam, Z.; Sun, L.; Samali, B. Seismic Performance of Asymmetric Building Structures; CRC Press: Boca Raton, FL, USA, 2020. [Google Scholar] [CrossRef] [Scilit]
- Chopra, A.K.; Goel, R.K. Evaluation of Torsional Provisions in Seismic Codes. J. Struct. Eng. 1991, 117, 3762–3782. [Google Scholar] [CrossRef] [Scilit]
- Ghersi, A.; Rossi, P.P. Influence of Bi-Directional Ground Motions on the Inelastic Response of One-Storey In-Plan Irregular Systems. Eng. Struct. 2001, 23, 579–591. [Google Scholar] [CrossRef] [Scilit]
- Paulay, T. Some Design Principles Relevant to Torsional Phenomena in Ductile Buildings. J. Earthq. Eng. 2001, 5, 273–308. [Google Scholar] [CrossRef] [Scilit]
- Kosmopoulos, A.J.; Fardis, M.N. Simple Models for Inelastic Seismic Analysis of Asymmetric Multistory RC Buildings. J. Earthq. Eng. 2008, 12, 704–727. [Google Scholar] [CrossRef] [Scilit]
- Lucchini, A.; Monti, G.; Kunnath, S. Nonlinear Response of Two-Way Asymmetric Single-Story Building under Biaxial Excitation. J. Struct. Eng. 2011, 137, 34–40. [Google Scholar] [CrossRef] [Scilit]
- Tabatabaei, R.; Saffari, H. Evaluation of the Torsional Response of Multistory Buildings Using Equivalent Static Eccentricity. J. Struct. Eng. 2011, 137, 862–868. [Google Scholar] [CrossRef] [Scilit]
- Basu, D.; Constantinou, M.C.; Whittaker, A.S. An Equivalent Accidental Eccentricity to Account for the Effects of Torsional Ground Motion on Structures. Eng. Struct. 2014, 69, 1–11. [Google Scholar] [CrossRef] [Scilit]
- Abdel Raheem, S.E.; Ahmed, M.M.; Ahmed, M.M.; Abdel-Shafy, A.G. Evaluation of Plan Configuration Irregularity Effects on Seismic Response Demands of L-Shaped MRF Buildings. Bull. Earthq. Eng. 2018, 16, 3845–3869. [Google Scholar] [CrossRef] [Scilit]
- Stathi, C.G.; Bakas, N.P.; Lagaros, N.D.; Papadrakakis, M. Ratio of Torsion (ROT): An Index for Assessing the Global Induced Torsion in Plan Irregular Buildings. Earthq. Struct. 2015, 9, 145–171. [Google Scholar] [CrossRef] [Scilit]
- Yaghoubi, E.; Emami, A.R.; Birzhandi, M.S. IDA-Based Collapse Safety Assessment of Torsional-Irregular Buildings, Considering Ductility and Damage. Int. J. Struct. Stab. Dyn. 2023, 23, 23502000. [Google Scholar] [CrossRef] [Scilit]
- Garcia, M.; de la Llera, J.C.; Almazán, J.L. Torsional Balance of Plan Asymmetric Structures with Viscoelastic Dampers. Eng. Struct. 2007, 29, 914–932. [Google Scholar] [CrossRef] [Scilit]
- Petti, L.; De Iuliis, M. Torsional Seismic Response Control of Asymmetric-Plan Systems by Using Viscous Dampers. Eng. Struct. 2008, 30, 3377–3388. [Google Scholar] [CrossRef] [Scilit]
- Castaldo, P.; De Iuliis, M. Optimal Integrated Seismic Design of Structural and Viscoelastic Bracing-Damper Systems. Earthq. Eng. Struct. Dyn. 2014, 43, 1809–1827. [Google Scholar] [CrossRef] [Scilit]
- Alam, Z.; Zhang, C.; Samali, B. The Role of Viscoelastic Damping on Retrofitting Seismic Performance of Asymmetric Reinforced Concrete Structures. Earthq. Eng. Eng. Vib. 2020, 19, 223–237. [Google Scholar] [CrossRef] [Scilit]
- Milanchian, R.; Hosseini, M. Torsional Response Reduction of Plan-Asymmetric Vertical Seismic Isolation by Appropriate Distribution of Viscous and Viscoelastic Dampers. Structures 2020, 27, 962–974. [Google Scholar] [CrossRef] [Scilit]
- Lin, J.L.; Liu, T.H.; Tsai, K.C. Real-Valued Modal Response History Analysis for Asymmetric-Plan Buildings with Nonlinear Viscous Dampers. Soil Dyn. Earthq. Eng. 2015, 77, 97–110. [Google Scholar] [CrossRef] [Scilit]
- Vial, I.J.; de la Llera, J.C.; Almazán, J.L.; Ceballos, V. Torsional balance of plan-asymmetric structures with frictional dampers: Experimental results. Earthq. Eng. Struct. Dyn. 2006, 35, 1875–1898. [Google Scholar] [CrossRef] [Scilit]
- Kim, J.; Jeong, J. Seismic Retrofit of Asymmetric Structures Using Steel Plate Slit Dampers. J. Constr. Steel Res. 2016, 120, 232–244. [Google Scholar] [CrossRef] [Scilit]
- Bakre, S.V.; Jangid, R.S.; Reddy, G.R. Optimum X-Plate Dampers for Seismic Response Control of Piping Systems. Int. J. Press. Vessel. Pip. 2006, 83, 672–685. [Google Scholar] [CrossRef] [Scilit]
- Sawai, G.; Dongawar, S. Seismic Performance of RC Building with X-Plate and Accordion Metallic Dampers. Int. J. Sci. Res. Eng. Manag. 2022, 6, 1–12. Available online: https://ijsrem.com/download/seismic-performance-of-rc-building-with-x-plate-and-accordion-metallic-dampers/fulltext.pdf (accessed on 20 November 2026).
- De Iuliis, M.; Petti, L.; Palazzo, B. Combined control strategy base isolation and tuned mass damper: An effectiveness analysis of its application to non-linear benchmark base isolated structure. In Proceedings of the 14th World Conference on Earthquake Engineering, Beijing, China, 12–17 October 2008. [Google Scholar]
- Petti, L.; De Iuliis, M. Robust design of a single tuned mass damper for controlling torsional response of asymmetric-plan systems. J. Earthq. Eng. 2008, 13, 108–128. [Google Scholar] [CrossRef] [Scilit]
- Espinoza, G.; Casanova, E.; Benedetti, F.; Mena, R.; Almazán, J.L. Optimal TMD Design for Torsional Balance of Asymmetrical 3D Structures Considering Soil–Structure Interaction. Struct. Control Health Monit. 2022, 29, e2858. [Google Scholar] [CrossRef] [Scilit]
- Espinoza, G.; Almazán, J.L.; Benedetti, F.; Jara, C. Torsional Balance of Nonlinear Asymmetrical Structures by Means of a Tuned Mass Damper. Struct. Control Health Monit. 2019, 26, e2442. [Google Scholar] [CrossRef] [Scilit]
- Desu, N.B.; Deb, S.K.; Dutta, A. Coupled Tuned Mass Dampers for Control of Coupled Vibrations in Asymmetric Buildings. Struct. Control Health Monit. 2006, 13, 897–916. [Google Scholar] [CrossRef] [Scilit]
- Huo, L.; Li, H. Torsionally Coupled Response Control of Structures. In Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, BC, Canada, 1–6 August 2004. Paper n.31. [Google Scholar]
- Fu, C. Transforming Method of TLCD-Structure to TMD-Structure for Vibration Control. KSCE J. Civ. Eng. 2018, 22, 1384–1393. [Google Scholar] [CrossRef] [Scilit]
- Wang, L.; Zhou, Y.; Nagarajaiah, S.; Shi, W. Bi-Directional Semi-Active Tuned Mass Damper for Torsional Asymmetric Structural Seismic Response Control. Eng. Struct. 2023, 294, 116744. [Google Scholar] [CrossRef] [Scilit]
- Pisal, A.Y.; Jangid, R.S. Dynamic Response of Structure with Tuned Mass Friction Damper. Int. J. Adv. Struct. Eng. 2016, 8, 363–377. [Google Scholar] [CrossRef] [Scilit]
- Sano, T.; Shirai, K.; Yoshida, O.; Nishikage, T. Assessment of a Seismic Tuned Mass Damper with Friction Fail-Safe Mechanism for the Vibration Control of High-Rise Buildings. Struct. Control Health Monit. 2021, 28, e2831. [Google Scholar] [CrossRef] [Scilit]
- Etedali, S.; Akbari, M.; Seifi, M. Friction Tuned Mass Dampers in Seismic-Excited High-Rise Buildings with SSI Effects: A Reliability Assessment. J. Earthq. Tsunami 2023, 17, 2250022. [Google Scholar] [CrossRef] [Scilit]
- Li, H.N.; Li, X.L. Experiment and Analysis of Torsional Seismic Responses for Asymmetric Structures with Semi-Active Control by MR Dampers. Smart Mater. Struct. 2009, 18, 075007. [Google Scholar] [CrossRef] [Scilit]
- Braz-César, M.; Barros, R. Optimal Control of a Plan Asymmetric Structure Using Magnetorheological Dampers. Arch. Appl. Mech. 2017, 87, 893–904. [Google Scholar] [CrossRef] [Scilit]
- Braz-César, M.T.; Folhento, P.L.; Barros, R.C. Numerical Simulation of Torsional Response Control of a Plan-Eccentric Mass Distribution Building by Using Magnetorheological Dampers. In 2018 13th APCA International Conference on Automatic Control and Soft Computing; IEEE: Piscataway, NJ, USA, 2018; pp. 358–363. [Google Scholar] [CrossRef] [Scilit]
- Zahrai, S.M.; Salehi, H. Semi-Active Seismic Control of Mid-Rise Structures Using Magneto-Rheological Dampers and Two Proposed Improving Mechanisms. Iran. J. Sci. Technol. Trans. Civ. Eng. 2014, 38, 21–36. Available online: https://journals.shirazu.ac.ir/article_1841_4b941151f1a70e762b59c337efa2735d.pdf (accessed on 20 November 2026).
- Panchanan, S.; Kumar, P.; Basu, S.; Jangid, R.S. Seismic Response of Asymmetric Structure with Soil–Structure Interaction Using Semi-Active MR Damper. In Recent Advances in Computational Mechanics and Simulations; Springer: Berlin/Heidelberg, Germany, 2021; pp. 457–468. [Google Scholar] [CrossRef] [Scilit]
- Bahar, A.; Pozo, F.; Meybodi, M.R.; Karami, S. Magnetorheological Fluid Dampers: A Close Look at Efficient Parametric Models. Struct. Control Health Monit. 2024, 2024, 6860185. [Google Scholar] [CrossRef] [Scilit]
- Sun, C.; Nagarajaiah, S. Study on Semi-Active Tuned Mass Damper with Variable Damping and Stiffness under Seismic Excitations. Struct. Control Health Monit. 2014, 21, 890–906. [Google Scholar] [CrossRef] [Scilit]
- Wang, L.; Shi, W.; Li, X.; Zhang, Q.; Zhou, Y. An Adaptive-Passive Retuning Device for a Pendulum Tuned Mass Damper Considering Mass Uncertainty and Optimum Frequency. Struct. Control Health Monit. 2019, 26, e2377. [Google Scholar] [CrossRef] [Scilit]
- Wang, L.; Nagarajaiah, S.; Shi, W.; Zhou, Y. Seismic Performance Improvement of Base-Isolated Structures Using a Semi-Active Tuned Mass Damper. Eng. Struct. 2022, 271, 114963. [Google Scholar] [CrossRef] [Scilit]
- Karami, K.; Ahmadi, H. Torsional Control of Asymmetric Buildings Using Online 3-D Damage Detection and Adaptive Stiffness Devices. Struct. Control Health Monit. 2021, 28, e2804. [Google Scholar] [CrossRef] [Scilit]
- McClamroch, N.H.; Gavin, H.P. Closed Loop Structural Control Using Electrorheological Dampers. In Proceedings of the 1995 American Control Conference; IEEE: Piscataway, NJ, USA, 1995; pp. 4173–4177. [Google Scholar] [CrossRef] [Scilit]
- Dyke, S.J.; Spencer, B.F.; Sain, M.K.; Carlson, J.D. Modeling and Control of Magnetorheological Dampers for Seismic Response Reduction. Smart Mater. Struct. 1996, 5, 565–575. [Google Scholar] [CrossRef] [Scilit]
- Sadek, F.; Mohraz, B. Semiactive Control Algorithms for Structures with Variable Dampers. J. Eng. Mech. 1998, 124, 981–990. [Google Scholar] [CrossRef] [Scilit]
- Li, C.; Gu, X. Design of Fluid Viscous Dampers for Single-Story Asymmetric-Plan Buildings Based on LQR Theory. In 2010 Second International Conference on Computer Modeling and Simulation 1; IEEE Computer Society: Washington, DC, USA, 2010; pp. 49–53. [Google Scholar]
- Pnevmatikos, N.G.; Hatzigeorgiou, G.D. Seismic Response of Active or Semi-Active Control for Irregular Buildings Based on Eigenvalues Modification. Earthq. Struct. 2014, 6, 647–664. [Google Scholar] [CrossRef] [Scilit]
- Sever, M.; Yazici, H.; Goktas, G.; Kucukdemiral, I.B. Disturbance Attenuation of Asymmetric Structure by LMI-Based Optimal State Feedback Controller with Saturated Actuators. In 2015 6th International Conference on Modeling, Simulation, and Applied Optimization; IEEE: Piscataway, NJ, USA, 2015; pp. 1–6. [Google Scholar] [CrossRef] [Scilit]
- Goel, R.K. Seismic Response of Asymmetric Systems: Energy-Based Approach. J. Struct. Eng. 1997, 123, 1444–1453. [Google Scholar] [CrossRef] [Scilit]
- Yanik, A.; Aldemir, U.; Bakioglu, M. Energy-Based Evaluation of Seismic Response of Structures with Passive and Active Systems. Earthq. Resist. Eng. Struct. 2011, 8, 67–78. [Google Scholar] [CrossRef] [Scilit]
- Zelleke, D.H.; Matsagar, V.A. Semi-Active Algorithm for Energy-Based Predictive Structural Control Using Tuned Mass Dampers. Comput.-Aided Civ. Infrastruct. Eng. 2019, 34, 1010–1025. [Google Scholar] [CrossRef] [Scilit]
- De Iuliis, M.; Castaldo, P. An Energy-Based Approach to the Seismic Control of One-Way Asymmetrical Structural Systems Using Semi-Active Devices. Ing. Sismica 2012, 29, 31–50. [Google Scholar]
- De Iuliis, M.; Miceli, E.; Castaldo, P. An Energy Framework to Control Viscoelastic Semi-Active Devices in Plan-Wise One-Way Asymmetric Systems. Struct. Control Health Monit. 2025, 2025, 7091316. [Google Scholar] [CrossRef] [Scilit]
- De Iuliis, M.; Miceli, E.; Castaldo, P. Machine Learning Modelling of Structural Response for Different Seismic Signal Characteristics: A Parametric Analysis. Appl. Soft Comput. 2024, 164, 112026. [Google Scholar] [CrossRef] [Scilit]
- Kobori, T. Active variable stiffness system-active seismic response control. In Proc. US-Italy-Japan Workshop/Symposium on Structural Control and Intelligent Systems; Elsevier Science: New York, NY, USA, 1992; pp. 140–153. [Google Scholar]
- Kamagata, S. Autonomous adaptive control of active variable stiffness system for seismic ground motion. In Proceedings of the First World Conference on Structural Control; IASC: Los Angeles, CA, USA, 1994; Volume 2, p. TA4-33. [Google Scholar]
- Karnopp, D.; Crosby, M.J.; Harwood, R.A. Vibration control using semi-active force generators. J. Eng. Ind. 1974, 96, 619–626. [Google Scholar] [CrossRef] [Scilit]
- Karnopp, D. Design principles for vibration control systems using semi-active dampers. J. Dyn. Syst. Meas. Control 1990, 112, 448–454. [Google Scholar] [CrossRef] [Scilit]
- Ahamadian, M. On the isolation properties of semiactive dampers. J. Vib. Control 1999, 5, 217–232. [Google Scholar] [CrossRef] [Scilit]
- Castaldo, P.; Miceli, E. Optimal Single Concave Sliding Device Properties for Isolated Multi-Span Continuous Deck Bridges Depending on the Ground Motion Characteristics. Soil Dyn. Earthq. Eng. 2023, 173, 108128. [Google Scholar] [CrossRef] [Scilit]
- Mavroeidis, G.P.; Papageorgiou, A.S. A mathematical representation of near-fault ground motions. Bull. Seismol. Soc. Am. 2003, 93, 1099–1131. [Google Scholar] [CrossRef] [Scilit]
- Somerville, P.G. Engineering characterization of near fault ground motions. In Proceedings of the 2005 NZSEE Conference; New Zealand Society for Earthquake Engineering: Christchurch, New Zealand, 2005. [Google Scholar]
- Zhu, T.J.; Tso, W.K.; Heidebrecht, A.C. Effect of peak ground a/v ratio on structural damage. J. Struct. Eng. 1998, 114, 1019–1037. [Google Scholar] [CrossRef] [Scilit]
- Tso, W.K.; Zhu, T.J.; Heidebrecht, A.C. Engineering implication of ground motion A/V ratio. Soil Dyn. Earthq. Eng. 1992, 11, 133–144. [Google Scholar] [CrossRef] [Scilit]
- De Iuliis, M.; Miceli, E.; Castaldo, P. Information theory-guided machine learning to estimate seismic response of non-linear SDOF structures. Eng. Struct. 2025, 336, 120448. [Google Scholar] [CrossRef] [Scilit]
- De Iuliis, M.; Miceli, E.; Castaldo, P. Energy-based semiactive algorithms for nonlinear frame structures using the force analogy method. Struct. Control Health Monit. 2026, 2026, 8260623. [Google Scholar] [CrossRef] [Scilit]
- Bray, J.D.; Rodriguez-Marek, A. Characterization of Forward-Directivity Ground Motions in the Near-Fault Region. Soil Dyn. Earthq. Eng. 2004, 24, 815–828. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.

![Pgv [s 1] and sed [m2.s 1]. blue dots are far field, red are near fault Pgv [s 1] and sed [m2.s 1]. blue dots are far field, red are near fault](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g009.png)

![Kg]. plot (a) is pacoima dam earthquake record #8 far field soil a. plot (b) is sylmar earthquake record #64 near fault soil c. both show no control and elastic energy minimization algorithm lines Kg]. plot (a) is pacoima dam earthquake record #8 far field soil a. plot (b) is sylmar earthquake record #64 near fault soil c. both show no control and elastic energy minimization algorithm lines](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g002.png)
![Kg] versus time t [sec] for no control and elastic energy minimization algorithm. plot a shows pacoima dam earthquake record #8 far field soil a. plot b shows sylmar earthquake record #64 near fault soil c Kg] versus time t [sec] for no control and elastic energy minimization algorithm. plot a shows pacoima dam earthquake record #8 far field soil a. plot b shows sylmar earthquake record #64 near fault soil c](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g003.png)

![Plot showing displacement waveforms for no control and elastic energy minimization algorithm. axes: y fl [m] versus t [sec]. (a) pacoima dam earthquake record #8, far field soil a, y fl 0.15 to 0.15 m. (b) sylmar earthquake record #64, near fault soil c, y fl 0.3 to 0.3 m Plot showing displacement waveforms for no control and elastic energy minimization algorithm. axes: y fl [m] versus t [sec]. (a) pacoima dam earthquake record #8, far field soil a, y fl 0.15 to 0.15 m. (b) sylmar earthquake record #64, near fault soil c, y fl 0.3 to 0.3 m](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g005.png)


![Multi panel plot showing stiffness switching activity. panel a and b: displacement (y fl [m]) vs time (t [s]) comparing elastic energy and kinetic energy laws for pacoima dam earthquake record 8 and sylmar earthquake record 64 respectively. panel c and d: stiffness state under elastic law with k max=0.2k y and k min=0. panel e and f: stiffness state under kinetic law with k max=0.2k y and k min=0 Multi panel plot showing stiffness switching activity. panel a and b: displacement (y fl [m]) vs time (t [s]) comparing elastic energy and kinetic energy laws for pacoima dam earthquake record 8 and sylmar earthquake record 64 respectively. panel c and d: stiffness state under elastic law with k max=0.2k y and k min=0. panel e and f: stiffness state under kinetic law with k max=0.2k y and k min=0](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g006b.png)
![Line chart showing the spectrum of the elastic energy reduction coefficient for different soil types. three subplots display data for soil a (24 events), soil b (43 events), and soil c (18 events). the vertical axis is labeled r~(ty), ranging from 30 to 75, and the horizontal axis is ty [sec], ranging from 0 to 2. a legend indicates dashed lines represent the median and solid lines represent the mean Line chart showing the spectrum of the elastic energy reduction coefficient for different soil types. three subplots display data for soil a (24 events), soil b (43 events), and soil c (18 events). the vertical axis is labeled r~(ty), ranging from 30 to 75, and the horizontal axis is ty [sec], ranging from 0 to 2. a legend indicates dashed lines represent the median and solid lines represent the mean](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g007.png)

![Scatter plots of peak edge displacement y max [m] vs record index for soil a (24 events), soil b (43 events), and soil c (18 events). each plot distinguishes elastic energy, kinetic energy, and dissipated energy control algorithms Scatter plots of peak edge displacement y max [m] vs record index for soil a (24 events), soil b (43 events), and soil c (18 events). each plot distinguishes elastic energy, kinetic energy, and dissipated energy control algorithms](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g011.png)



![Relational diagram showing algorithm selection maps for different supplemental resources across four subplots (a d). the y axis categorizes resource types: soil a, soil b, soil c, far field, near fault. the x axis represents ty [sec] from 0.1 to 2.0. highlighted rectangular regions indicate specific algorithm selections within this parameter space for each resource category Relational diagram showing algorithm selection maps for different supplemental resources across four subplots (a d). the y axis categorizes resource types: soil a, soil b, soil c, far field, near fault. the x axis represents ty [sec] from 0.1 to 2.0. highlighted rectangular regions indicate specific algorithm selections within this parameter space for each resource category](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g015.png)



![Relational diagram of two line graphs. graph (a) labeled elastic energy law tau=50 ms plots increase in y max [%] versus ty [s] for record #8 (ff) and record #64 (nf). graph (b) labeled kinetic energy law tau=50 ms plots the same y axis against the same x axis Relational diagram of two line graphs. graph (a) labeled elastic energy law tau=50 ms plots increase in y max [%] versus ty [s] for record #8 (ff) and record #64 (nf). graph (b) labeled kinetic energy law tau=50 ms plots the same y axis against the same x axis](https://mdpi-res.com/buildings/buildings-16-04704/article_deploy/html/images/buildings-16-04704-g019.png)