Cradle-to-Gate Embodied Carbon of Building Facade and Enclosure Systems: A Systematic Review

,
,
,
and
1
Environmental Dynamics Ph.D. Program, Graduate School and International Education, University of Arkansas, Fayetteville, AR 72701, USA
2
Fay Jones School of Architecture and Design, University of Arkansas, Fayetteville, AR 72701, USA
3
Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA
*
Author to whom correspondence should be addressed.

Abstract

Published life cycle assessment (LCA) results for building facades and enclosures are difficult to compare because of differences in system scope, methods, and reporting. This systematic review synthesizes cradle-to-gate embodied carbon results by system type and assesses their comparability. Following PRISMA 2020, searches of five databases, supplementary searches, and citation tracking (2010 to January 2026) identified 146 studies with 800 options in 13 system types. The primary dataset contained 597 options with strict A1–A3 results per square meter of facade or enclosure. Their median global warming potential (GWP) ranged from 9.1 kg CO2e/m2 for insulation components to 207 kg CO2e/m2 for building-integrated photovoltaic (BIPV) modules. Opaque walls, the largest category (231 options, 52 studies), had a median of 48 kg CO2e/m2. Using one value per study changed medians by less than 4 kg CO2e/m2 in the four largest categories and up to 72 kg CO2e/m2 in smaller ones. Therefore, small-category results are descriptive only. Comparison was limited because one-quarter of options were not reported per facade area or the reporting included stages beyond A1–A3. In addition, for 48% of options containing bio-based materials, studies did not state whether stored carbon was credited. In studies that reported both versions, the credit alone turned 15 of 26 results negative. Values should therefore be compared only within a category and at equivalent performance, boundary, and biogenic carbon treatment. To address these gaps, this review proposes a minimum reporting checklist for consistent and comparable facade LCA results.

1. Introduction

A building’s facade does two jobs at once; it is the surface the building presents, and it is the environmental separator that keeps weather out, admits daylight while limiting glare, carries its own weight and sometimes the floors, and manages moisture. These functions require different materials and layers with different service lives and replacement needs. As operational energy use decreases, the embodied carbon of facade materials becomes a larger part of the building’s total environmental impact and a more important factor in design decisions. This is especially relevant for material-intensive systems such as curtain walls, glazing units, multilayer opaque walls, cladding systems, insulation assemblies, and active facade modules.
Life cycle assessment (LCA) is the standard method for quantifying the embodied carbon of building materials and systems. Facade LCA studies compare material choices, system configurations, and retrofit strategies. They also consider embodied carbon alongside building performance because options with a lower production-stage global warming potential (GWP) may differ in material quantity, thermal performance, or operational carbon [1,2,3]. However, even well-conducted facade LCA studies can produce results that cannot be compared directly. The facade is often studied not as a distinct system but as one contribution within a whole building assessment, where its carbon is not isolated. The boundary also shifts from study to study, from cradle-to-gate in one, cradle-to-grave in another, and cradle-to-cradle or whole-life carbon in a third [4,5,6,7]. The functional unit varies as well. Whole building assessments often express results per square meter of gross floor area rather than of facade or wall area, so even values given per square meter may not be directly comparable [8]. Results also depend on the life cycle inventory database, the method used to calculate GWP from greenhouse gas emissions, the life cycle stages included, and the assumed service life [9,10,11,12,13].
Each facade and enclosure system type raises its own comparability questions. Window and glazing studies fall into three groups. The first assesses the glazing itself, such as aerogel, electrochromic, and curtain wall glazing, and asks whether the higher carbon of producing advanced glazing is worth its better thermal or optical performance [2,14,15]. The second assesses the complete window, comparing frame materials, evaluating wooden windows with Environmental Product Declaration (EPD) data, comparing fixed and operable windows, and assessing a new hidden-frame window design [13,16,17,18,19]. The third focuses on window retrofit decisions. Some studies compare maintaining versus replacing existing windows or assess glazing upgrades in existing buildings. These studies evaluate whether an intervention provides environmental benefits. The carbon benefit of a window retrofit depends on the climate and building type because heating and cooling demand vary, as studies in subarctic Sweden and Iran have shown [20,21]. The groups also differ in how results are reported. Glazing studies usually report results per square meter of glazing, whereas window studies report them per square meter of window including the frame, per window unit, or per floor area; so, the two cannot be compared directly.
Curtain walls and double-skin facades are studied at the system level. Some curtain wall studies examine ways to reduce the environmental impact of aluminum framing, for example by replacing it with wood-based or bio-composite profiles, and one study also compares end of life options [1,22,23]. Double-skin facade studies usually assess the complete assembly, including fiber-reinforced or lightweight concrete systems with air gaps. Their results are often evaluated under the specific climate conditions for which the systems were designed [3,24,25].
Opaque walls are the largest and most varied stream. They span light frame, cross-laminated timber, and glued laminated timber wall assemblies [26], and concrete and massive stone walls built to the same structural and thermal brief [27]. They also include earthen and natural assemblies such as cob, straw clay, and rammed earth [28], and circular bio-based panels designed for disassembly, reuse, and recycling at end of life [29]. Earthen walls have also been compared with conventional walls of similar thermal performance [30,31], which provides a more consistent basis for comparing their embodied carbon.
What makes this stream hard to pool is not the range of materials but the range of yardsticks. Opaque wall studies use different reference areas. Most use wall area and some use floor area, while others report only a total for the assembly or the whole building that cannot be reliably converted to a value per square meter. For example, Quinn et al. [32] assessed 17 residential wall assemblies using three LCA datasets, with values ranging from 9 to 44.6 kg CO2e/m2. All values were cradle-to-gate (A1–A3) and are expressed per 1 m2 of wall, excluding windows and doors. Idrissi Kaitouni et al. [8], in contrast, report whole building embodied carbon values of 3.41 and 6.3 kg CO2e/m2·y. Their paper gives no separate result for the facade or enclosure, and an envelope value can only be obtained by adding up the envelope materials in its inventory. In that study, the square meter refers to gross floor area, and the values are annualized over a 50-year reference study period. Although both studies use area-normalized carbon values, their system scope, denominator, unit, and time basis are different. Their results are therefore not directly comparable (Figure 1). This figure illustrates this point with two simplified examples based on these studies.
Figure 1. Why two area-based facade carbon results may not be comparable. Example A reports the A1–A3 total of one wall assembly per m2 of net wall area as a one-time value. Example B adds up the envelope materials of a whole building inventory and expresses the total per m2 of gross floor area per year of the study period. The boundary is the same, but system scope, denominator, unit, and time basis differ.
Insulation and render studies are difficult to compare because they use different functional units and assess different parts of the facade. Many examine individual materials or coating systems rather than complete wall assemblies. Pargana et al. [33] examined the environmental impacts of producing conventional insulation materials, while Sierra-Pérez et al. [34] evaluated agglomerated cork insulation boards using a cradle-to-gate LCA. Pedroso et al. [35] assessed aerogel-based insulating renders and the multilayer coating systems containing them. Zhilyaev et al. [36] used a volume-based unit, 1 m3 of a cement-based foam containing phase change materials. Some studies compare insulation materials using a specified thermal target. Zabek et al. [37] used a thermal resistance of 1 m2K/W, adjusting each material’s thickness to meet this target and reporting GWP per square meter. Other studies have used a target U-value of 0.20 W/m2K [38], assessed vacuum insulation panels with a U-value of 0.27 W/m2K [39], or select insulation thickness to meet building code requirements [40]. Results reported per kilogram can be converted to kg CO2e/m2 if the mass per square meter is known; results reported per cubic meter can be converted if the layer thickness is known. However, using the same unit does not mean the results cover the same components, because insulation and coating results exclude the other parts of a complete facade. This review therefore reports insulation components and render layers as separate categories (Section 2.5).
Studies of cladding and facade panels assess the building’s outer skin on its own, and because cladding can be unbolted and replaced, end-of-life and reuse questions are relevant here. One study compared ceramic panels with metal, stone, and glass alternatives per square meter [41]. Another study looked at metal cladding after demolition and counted the emissions saved by recycling it instead of sending it to landfill [42]. A closed-cavity double-skin facade was assessed across reuse, component recovery, and recycling scenarios over a hundred-year study period [43]. Even for timber cladding, which has low carbon itself, the result depends strongly on surface treatment and maintenance over its service life [44]. Recycling credits and end-of-life assumptions can thus substantially reduce the net carbon of cladding and change which end-of-life route performs best.
Three smaller groups of studies, on building-integrated photovoltaic (BIPV) facades, 3D-printed walls, and living walls, are treated separately because these systems work differently from conventional facades. BIPV facades fold power generation into the envelope, so that their assessments can include inverter replacement and module end of life that a passive wall never incurs [45]. Their results are often reported per module, per kilowatt-peak (kWp), or per kilowatt-hour (kWh) of generated electricity rather than per square meter of facade [46,47,48,49]. Three-dimensional printed walls are built by depositing material in one continuous process instead of assembling separate layers. Studies of these report their results in different units. One reports per square meter of wall [50], and another assesses a complete 3 m × 3 m × 0.22 m printed wall element [51]. Living and green facades add vegetation, substrate, and irrigation that conventional walls do not have [52,53]. None of these is functionally equivalent to a conventional wall; a facade reference range has to keep them in separate categories.
This variety is why a single pooled facade embodied carbon value would be misleading and why synthesis has to proceed system type by system type. The problem is not a shortage of LCA studies but a shortage of comparability. As well as differing in boundary and functional unit, some studies give layer quantities and others only aggregated totals. Some credit the biogenic carbon stored in timber and plant-based materials, others exclude it, and others leave it unstated. Hotspots are also located at different levels, such as the material, process, component, or life cycle module. These differences change the magnitude of the reported GWP and can affect which systems appear low-carbon. Therefore, results from different studies should be compared only after checking their system scope, area basis, life cycle boundary, biogenic carbon treatment, and time basis.
Existing reviews do not close this gap. Reviews of building embodied carbon synthesize whole building totals per m2 of floor area or mitigation strategies in which the envelope is one contributor among many [54,55]. Reviews of building envelope sustainability are largely qualitative or technology focused. Kumar et al. [56] organized 260 studies of envelope design around energy, comfort, economic, and environmental performance criteria but did not extract or compare embodied carbon values. Kitsopoulou et al. [57] mapped passive envelope technologies by energy savings and investment cost rather than embodied GWP. Attia et al. [58] classified adaptive facade concepts through expert interviews. Vilches et al. [59] reviewed LCA studies of building refurbishment and found the same inconsistent boundaries and functional units. However, their review focused on classifying methods rather than extracting, normalizing, or comparing the reported LCA values. We are not aware of any review that has assembled per square meter cradle-to-gate reference ranges by facade and enclosure system type, tested their stability against data quality and study dominance, or quantified how far functional unit and biogenic carbon choices move the reported values. Research in this area is growing quickly, and future studies may address this gap.
This review asks what ranges of cradle-to-gate embodied carbon are reported across facade and enclosure system types and which design and modeling choices drive the differences. It follows PRISMA 2020 and the PRISMA-S search reporting extension [60,61]. Across the 800 options from 146 studies, much of the variation in reported GWP appears to reflect reporting and accounting methods as well as the facade systems themselves. Only 75% of the options (597 of 800) could be expressed as strict A1–A3 results on a common per square meter basis, and biogenic carbon treatment was unclear or not reported for 48% of the comparable options that contain bio-based material. In response, the review provides system specific A1–A3 GWP reference ranges per square meter and tests their stability against outliers, data quality, boundary mappability, biogenic carbon treatment, and single-paper dominance. It also proposes a minimum reporting checklist for facade LCA studies, based on the problems found.

2. Methods

2.1. Review Design and Reporting Framework

The review was designed and executed following the PRISMA 2020 framework and covers peer-reviewed studies that report cradle-to-gate embodied carbon for building facade and enclosure systems. PRISMA was chosen to structure the identification, screening, and eligibility assessment of studies [60]. The eligibility criteria and the extraction template were defined before screening began. The search covered English-language studies published from 2010 to 12 January 2026, the date of the first database search. The window opened in 2010, shortly before EN 15804 was first published in 2012, which introduced the A1–A3 product stage used in this review [62]. Studies were identified in two stages. The database search in January 2026 included 105 studies. Supplementary searches and citation tracking in October 2026 added 41 studies, giving 146 included studies in total (Section 2.2).
The review focused on A1–A3 GWP, which was the most consistently reported stage boundary across facade and enclosure LCA studies. GWP was the only environmental impact category that the studies reported consistently, so it was the only one included in the quantitative synthesis. Trade-offs with other impact categories are discussed in Section 4.1 and Section 5. The primary analysis includes only options whose reported boundary strictly matches A1–A3. Sixty-five options from 15 papers did not fully match A1–A3, mostly because they included transport to the construction site (A4), and in some cases installation (A5), which could not be separated from A1–A3. These options were flagged as partial and kept only for the boundary sensitivity analysis and the A1–A3 mappability comparison (Section 2.7). A4 was recorded when reported but not analyzed as a separate stage, because few studies reported it separately. The review did not analyze stages after A3, such as the use stage and the end-of-life stage. These stages are reported less consistently and depend strongly on assumptions such as service life, climate, and end-of-life modeling.

2.2. Information Sources and Search Strategy

The database search was conducted on 12 January 2026 across five sources, namely, Web of Science Core Collection, ScienceDirect, GreenFILE, Art and Architecture Source, and Avery Index to Architectural Periodicals. Language and document type filters were applied where available. The search strings combined terms related to LCA, embodied carbon, facades, and enclosures, with some also specifying materials or system boundaries.
The search strategy was designed to capture complete assemblies as well as separable facade components, because many studies compare cladding, insulation, glazing, or retrofit layers while holding other parts of the enclosure constant. The complete Boolean search string for each database is given below, and the record counts at each filtering step are summarized in Table 1.
Table 1. Search strategy and record counts (time window 2010 to January 2026).
Web of ScienceCore Collection (Clarivate, advanced search): TS = ((“life cycle assessment” OR LCA OR “embodied carbon” OR “global warming potential” OR GWP OR “cradle to gate” OR “cradle-to-gate” OR “EN 15804” OR “A1–A3” OR “A1 to A3”) AND (facade* OR façade* OR envelope* OR “building enclosure” OR “wall assembly” OR cladding OR glazing OR “curtain wall” OR storefront OR “cavity wall” OR mullion*) AND (timber OR wood OR “mass timber” OR CLT OR “cross laminated timber” OR “cross-laminated timber” OR aluminum OR masonry OR brick OR concrete OR steel)).
ScienceDirect (Elsevier): (“embodied carbon” OR “life cycle assessment”) AND (facade OR “building envelope”) AND (“A1–A3” OR “EN 15804” OR EPD OR “cradle-to-gate”).
GreenFILE (EBSCOhost): TX ((“life cycle assessment” OR LCA OR “embodied carbon” OR “global warming potential” OR GWP OR “cradle to gate” OR “cradle-to-gate” OR “EN 15804” OR “A1–A3” OR “A1 to A3”) AND (facade* OR façade* OR envelope* OR “building enclosure” OR “wall assembly” OR cladding OR glazing OR “curtain wall” OR storefront OR “cavity wall” OR mullion*) AND (timber OR wood OR “mass timber” OR CLT OR “cross laminated timber” OR “cross-laminated timber” OR aluminum OR masonry OR brick OR concrete OR steel)).
Art and Architecture Source (EBSCOhost): TX ((“life cycle assessment” OR LCA OR “embodied carbon” OR “global warming potential” OR GWP OR “cradle to gate” OR “cradle-to-gate” OR “EN 15804” OR “A1–A3”) AND (facade* OR façade* OR envelope* OR “building enclosure” OR “wall assembly” OR cladding OR glazing OR “curtain wall” OR storefront OR “cavity wall” OR mullion*)).
Avery Index to Architectural Periodicals (EBSCOhost): (“embodied carbon” OR “life cycle assessment” OR LCA OR “global warming potential” OR GWP) AND (facade OR façade OR envelope OR cladding OR “curtain wall” OR “building enclosure”).
The ScienceDirect string is narrower than the Web of Science string because the platform limits advanced queries to eight Boolean connectors. Scopus was not searched, because the authors’ institution does not subscribe to it. Instead, the review relied on Web of Science Core Collection, which covers many of the same journals, and added Lens.org in the supplementary searches to include records across publishers. Other limitations of search coverage are discussed in Section 5.
To check whether the January search had missed relevant studies, each of the 105 included studies was traced back to the databases that had retrieved it (Supplementary Materials, Table S1). The Web of Science and GreenFILE strings required a structural material term and did not include component terms such as insulation, cork, or aerogel. As a result, they retrieved only 1 of the 14 included insulation studies, and similar component studies could have been missed. The search was therefore extended in October 2026, limited to records first available online on or before 12 January 2026 so that the time window of the review did not change. Web of Science and GreenFILE were searched again with component and material terms instead of structural material terms. Records already found by the January search were excluded. Lens.org was searched to include records across publishers. In addition, articles published from 2010 onward that were cited by at least two of the 105 studies were screened (backward citation tracking). The new records were screened with the same eligibility criteria as in January. The supplementary search strings were as follows.
Web of Science Core Collection (supplementary search, 6 October 2026): TS = ((“life cycle assessment” OR LCA OR “embodied carbon” OR “global warming potential” OR GWP OR “cradle to gate” OR “cradle-to-gate” OR “EN 15804” OR “A1–A3” OR “A1 to A3”) AND (facade* OR façade* OR envelope* OR “building enclosure” OR “wall assembly” OR cladding OR glazing OR “curtain wall” OR storefront OR “cavity wall” OR mullion*) AND (insulation OR insulat* OR cork OR aerogel OR hemp* OR straw OR “rammed earth” OR adobe OR earthen OR “mineral wool” OR “glass wool” OR “rock wool” OR “stone wool” OR cellulose OR “wood fib*” OR “wood fibre” OR “vacuum insulation” OR polystyrene OR EPS OR XPS OR polyurethane OR PIR OR phenolic OR render* OR mortar OR plaster* OR “green wall” OR “living wall” OR “green facade” OR “vertical greenery” OR photovoltaic OR BIPV OR “3D print*” OR “3D-print*” OR “additive manufactur*” OR “shading device” OR louver* OR louvre* OR “double skin” OR “double-skin”)) NOT TS = (timber OR wood OR “mass timber” OR CLT OR “cross laminated timber” OR “cross-laminated timber” OR aluminum OR masonry OR brick OR concrete OR steel).
GreenFILE (EBSCOhost, supplementary search, 6 October 2026): TX ((“life cycle assessment” OR LCA OR “embodied carbon” OR “global warming potential” OR GWP OR “cradle to gate” OR “cradle-to-gate” OR “EN 15804” OR “A1–A3” OR “A1 to A3”) AND (facade* OR façade* OR envelope* OR “building enclosure” OR “wall assembly” OR cladding OR glazing OR “curtain wall” OR storefront OR “cavity wall” OR mullion*) AND (insulation OR insulat* OR cork OR aerogel OR hemp* OR straw OR “rammed earth” OR adobe OR earthen OR “mineral wool” OR “glass wool” OR “rock wool” OR “stone wool” OR cellulose OR “wood fib*” OR “vacuum insulation” OR polystyrene OR EPS OR XPS OR polyurethane OR PIR OR phenolic OR render* OR mortar OR plaster* OR “green wall” OR “living wall” OR “green facade” OR photovoltaic OR BIPV OR “3D print*” OR “additive manufactur*” OR “shading device” OR louver* OR “double skin”)) NOT TX (timber OR wood OR “mass timber” OR CLT OR “cross laminated timber” OR aluminum OR masonry OR brick OR concrete OR steel).
Lens.org (title, abstract, keyword, and field of study, journal articles, 6 October 2026): (“embodied carbon” OR “life cycle assessment” OR “cradle to gate” OR “cradle-to-gate”) AND (facade OR façade OR “building envelope” OR cladding OR “curtain wall” OR “wall assembly”) AND (“A1–A3” OR “EN 15804” OR “product stage” OR “embodied carbon” OR “cradle to gate” OR “cradle-to-gate”).
These searches added 41 studies [30,31,38,39,40,46,47,48,49,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79,80,81,82,83,84,85,86,87,88,89,90,91,92,93,94], 23 from Web of Science, 17 from citation tracking, and 1 from Lens.org, giving 146 included studies in total (Table 1; Section 3.1). Overall, 11 of the 23 Web of Science studies were insulation, render, glazing, or living wall studies, which confirms that the gap was real. Section 3.3 reports how these 41 studies changed the results.

2.3. Eligibility Criteria and Screening

All records were exported to Rayyan(https://www.rayyan.ai/, accessed on 19 October 2026), a screening platform. The reviewers screened titles and abstracts independently in blind mode and reconciled discrepancies afterward.
Studies were included when they assessed a building facade or enclosure system, either a complete assembly or a separable component, with LCA or another quantified embodied carbon method. They also had to report A1–A3 GWP, or enough data to map the result to A1–A3 and give a separable facade or enclosure result in a unit that was clear or could be normalized. Studies that did not meet these criteria were excluded at full text under six codes. The codes were operational only (E1), no quantified LCA results (E2), whole building only (E3), boundary not mappable to A1–A3 (E4), unit not interpretable (E5), and outside the facade or enclosure scope (E6).
For borderline cases, values were included only when they were reported in tables or clearly labeled figures or could be derived with one transparent arithmetic step. Values were excluded when A1–A3 required reconstruction from unlabeled stacked bar segments, back calculation from aggregated totals, mixed-unit conversion, or multiple compounding reviewer assumptions.

2.4. Data Extraction

A structured template captured bibliographic data, building context, functional or declared unit, boundary and modules, standards, software, life cycle inventory sources, impact method, biogenic carbon handling, facade option and system type, key layers, thermal target, service life, A1–A3 GWP, A4 where reported, normalization method, hotspots, sensitivity analysis, and quality flags.
Each facade option was entered as a separate row. All reported versions of each option with A1–A3 results were extracted, including different production methods, sensitivity scenarios, and service life assumptions, with two exceptions. First, when a paper reported the same options using several LCA tools (for example Athena, Tally, and One Click LCA) or background databases, only the results used in the authors’ main comparison were extracted. Second, when a paper reported the same option with and without a biogenic carbon credit, we kept the paper’s own main A1–A3 result and did not add or subtract the credit ourselves. The other value, where it could be determined, was recorded as a paired observation; it is used only to compare the same option with and without the credit (Section 3.5).
When a study reported an average, that value was used. When it reported a range, both endpoints were recorded and the midpoint was used in the analysis. Each option contributed one value to the analysis. Because some papers reported many options, a paper-level check gives each paper one value (the median of its options) to test whether these papers dominate the results (Section 2.7). All included studies are listed in the Supplementary Materials.

2.5. Data Cleaning and Harmonization

Raw extracted values were kept unchanged, and cleaned values were added in adjacent columns. Numeric fields were split into value, minimum, and maximum. Each GWP value was normalized per m2 and labeled Yes (accepted point value), Range (accepted interval, represented by its midpoint, with both bounds kept), Not possible (no defensible per m2 value), or Blank (no result).
The extracted system type field contained more than 100 unique free-text descriptions, which made any comparison by system family impossible without harmonization. We therefore assigned every row to one of 13 mutually exclusive categories: opaque wall assembly, insulation component, window or door, roof enclosure, cladding system, 3D-printed wall assembly, render or mortar layer, curtain wall system, glazing or shading device, floor or ground enclosure, whole envelope bundle, BIPV or active facade module, and living wall or green facade. The category set was derived from the data rather than fixed in advance.
Each row was classified according to the facade system assessed in the study, using the reported system type, facade option name, and layer description together. The paper title alone was not used for classification. When a row fitted more than one category, the more specific one was chosen. For example, a 3D-printed wall was classified as a 3D-printed wall assembly rather than an opaque wall. System scope was also considered. A result for cladding only was classified as a cladding system, a complete wall that included cladding as an opaque wall assembly, and a result combining walls, windows, and roof as a whole envelope bundle.
Systems were grouped by function and construction technology. Those serving the same function but differing only in material were placed in the same category. Curtain walls, 3D-printed walls, BIPV modules, living walls, and renders were classified separately because of their distinct functions or construction methods. Curtain walls are framed, mostly glazed, non-load bearing systems; 3D-printed walls use a distinct production process; BIPV modules generate electricity; living walls support vegetation; and renders are surface layers applied at a specified thickness. Timber, masonry, concrete, earth, and hybrid walls were grouped as opaque walls. Results by material are presented in Section 3.3 and Supplementary Materials, Table S2f. The window or door category includes eight rows covering doors or combined window-and-door results from three papers that did not provide separate values. Frameless glazing units and glazing-integrated shading were grouped in the glazing or shading device category, separately from framed windows. Each category is supported by at least three papers.
Each option was also given a label that shows whether its result covers a whole wall (or roof or floor), a single product, or only part of a wall. A complete assembly is the full build-up of a wall, roof, floor, curtain wall, or 3D-printed wall. A component product is a complete single product, such as an insulation board, a render, a cladding system, a window, a glazing unit, a BIPV module, or a living wall module. A partial element is a result for an assembly, such as a wall, roof, or floor, that does not include all its layers, for example only the structural layer or the assembly without its finishes. A retrofit add-on covers only the new layers added to an existing wall or roof. Labels in the assembly categories were checked against the source paper (Supplementary Materials, Extraction Data, column BL).
Four quality flags (unit clarity, boundary clarity, separability of the facade result, and data transparency) define a high confidence subset in which all four are affirmative. The flags describe how clearly each result is reported and how comparable it is, not whether the study is unbiased or of high quality, and no formal risk-of-bias assessment was made. However, study quality was assessed separately with a six-check appraisal (Section 2.7).

2.6. Statistical Synthesis

Because the included studies differed widely in boundary, functional unit, geographic context, system scope, data source, impact method, service life, and performance equivalence, we used descriptive statistics rather than a single meta-analytic estimate. For each system category, we calculated the number of rows and unique papers, the minimum, first quartile, median, mean, third quartile, maximum, and interquartile range (IQR). Medians and IQRs are used throughout, because the distributions are right-skewed and include some negative values from biogenic carbon credits.
Of the 800 facade and enclosure options, 597 rows from 111 papers reported a strict A1–A3 result comparable per m2 and form the primary dataset. The others were not comparable per m2 (138 rows) or had a boundary wider than A1–A3 (65 rows). These 203 options were not spread evenly across system types. They included all whole envelope bundles (reported per m2 of floor area), most render or mortar layers (reported per m3 of mortar), and many roofs and floors, but few glazing or shading and 3D-printed wall options and no curtain walls or living walls (Supplementary Materials, Table S2g). The primary dataset therefore under-represents renders and whole envelope results. In total, 45 papers had at least one option excluded, and 35 papers had no option in the primary dataset, which therefore comprised 111 of the 146 papers. Statistics were calculated in Microsoft Excel (version 16), and figures were created in R (version 4.5.1) with ggplot2 (version 4.0.0).

2.7. Sensitivity and Subgroup Analyses

Five sensitivity analyses tested whether the reference values changed under different inclusion or weighting rules, and two subgroup comparisons tested whether results differed between methodological groups.
First, two unusually high GWP values were verified against the source paper and kept in the primary dataset of 597 rows; a sensitivity analysis excluded these two values, resulting in a subset of 595 rows. Second, a high confidence subset kept only rows that passed all four quality flags (Section 2.5). Third, two tests examined whether a single paper with many options dominated the results. One used the median of each paper’s options within each category, giving every paper equal weight. The other recalculated each category median after removing one paper at a time. This leave-one-study-out test measured how much each paper affected the category median. Fourth, to test whether the strict A1–A3 rule changed the results, the 61 Partial rows with a per m2 value were combined with the primary dataset and the category medians were recalculated. Fifth, each of the 146 papers was assessed using six yes-or-no quality checks based on the extracted information (Supplementary Materials, Table S4a). No validated risk-of-bias tool exists for LCA studies, so the checks were based on ISO 14044 reporting requirements. The checks asked whether the paper (1) named an LCA standard, (2) identified the background data source, (3) stated the GWP characterization method, (4) reported cut-off or allocation rules, (5) included a sensitivity or uncertainty analysis of the carbon results, and (6) was independent of the producer of the assessed product, meaning that no producer or trade association funded the study or employed an author. Each “yes” received one point, giving a total score from 0 to 6. No paper was excluded based on its score. Category medians were recalculated separately for papers scoring at least 4 and those scoring at least 5. These medians were compared with the main results to determine whether excluding lower-scoring papers changed the findings (Section 3.4; Supplementary Materials, Table S4c).
The first subgroup comparison grouped rows by how biogenic carbon was treated. Options without bio-based materials were classified as not applicable. The remaining options were labeled as credited when the reported GWP included a deduction for stored biogenic carbon, not credited when no deduction was applied, and not reported or unclear when the paper did not clearly state how biogenic carbon was treated. An initial label was assigned using a simple rule based on negative GWP values or words such as “sequestration”, “storage”, or “biogenic” in the extraction notes. Each row was then checked manually against the notes and, where necessary, the source paper. A row was labeled as not reported or unclear only after reviewing the paper’s methods, inventory tables, and supplementary files. The final not reported or unclear group contained 133 rows from 35 papers, representing 48% of the rows containing bio-based materials. The second subgroup comparison divided options into three groups based on how their results related to the A1–A3 boundary. These were A1–A3 values reported directly, values calculated in one step from the paper’s data and values whose boundary did not fully match A1–A3. Reported GWP was compared across these groups to examine whether differences in boundary reporting were associated with differences in GWP.

3. Results

3.1. Study Selection and Evidence Base

The first search identified 1508 records across five databases. Rayyan flagged 232 as potential duplicates. Of these, 124 were confirmed as duplicates and removed, leaving 1384 records for title and abstract screening. Full text assessment was conducted for 419 records, and 105 papers met the inclusion criteria. These 105 papers provided 621 facade option rows. Initially, 501 rows had values per m2. Verification against the original papers led to the exclusion of nine rows. In seven rows from two studies, values per m2 had been calculated during extraction by dividing a reported carbon total by a reported area. These rows were excluded because it could not be confirmed that the total and area covered the same part of the building. The other two rows covered whole envelopes, and their values were derived per m2 of gross floor area per year, rather than per m2 of facade or enclosure area (see Figure 1). A further 26 rows had values per m2 but included stages beyond A1–A3 and were excluded from the primary dataset (Section 2.1). The first database searches therefore contributed 466 rows from 78 papers covering A1–A3 only. The supplementary searches added 41 studies. Thirty-three of these contributed 131 rows to the primary dataset, and the other eight had no option that met the per m2 and strict A1–A3 criteria. Together, these formed the primary dataset of 597 rows from 111 papers.
Table 2 and Table 3 give the PRISMA flow counts and the full text exclusion reasons. Of the 532 records assessed in full text, 386 were excluded. Most were excluded because the LCA boundary could not be mapped to A1–A3 (190) or because only whole building totals were reported, without a separable facade or enclosure result (96). In total, 223 of the 386 exclusions (190 boundary cases and 33 with a unit that could not be interpreted) were caused by how results were reported rather than by the topic. Figure 2 shows the selection flow.
Table 2. PRISMA 2020 flow counts.
Table 3. Full text exclusion reasons.
Figure 2. PRISMA 2020 flow diagram for study selection. The database search and the supplementary searches identified 2263 records. Of these, 146 studies met the inclusion criteria and provided 800 facade option rows.

3.2. Publication Volume and Recency of the Evidence Base

The evidence base is young. From the 146 included studies, 96 (roughly 66%) were published between 2020 and 2026, while 2010 returned no eligible studies (Figure 3). The reference ranges therefore reflect the studies available today and may change as new studies are published.
Figure 3. Publication volume of included studies by year (n = 146). The 2026 bar is partial because the searches cover publications up to 12 January 2026.
The high numbers of options for 2022, 2024, and 2025 are partly due to a few studies that reported many scenarios or product variants (Table 4). Publication year is used only to show the growth of the field, not trends in GWP, because each year covers different facade systems and technologies.
Table 4. Publication volume summary.

3.3. Normalized A1–A3 GWP by Facade and Enclosure System Type

Comparability on a per m2 basis was the main obstacle to synthesis. From the 800 extracted options, 138 could not be normalized per m2. Table 5 reports the descriptive statistics for the 597 primary rows, and Figure 4 plots these. Both also show the paper-level median of each category (one value per paper, Section 3.6), so that categories driven by a single study can be recognized. Median normalized GWP ranged from 9.1 kg CO2e/m2 for insulation components to 207 kg CO2e/m2 for BIPV or active facade modules. The whole envelope bundle category had no comparable results. Its only candidate combined the walls with a roof that was assumed to use the same construction as the walls, so it was reclassified as an opaque wall assembly.
Table 5. Descriptive statistics of normalized A1–A3 GWP by system type, primary dataset. Papers can contribute to more than one category. The paper-level median gives each paper one value.
Figure 4. Normalized A1–A3 GWP by system type (n = number of rows). The 27 negative values are included in the statistics but cannot be shown on the log scale (minima in Table 5).
The three highest medians come from only a few papers. BIPV or active facade modules had a median of 207 kg CO2e/m2 from six papers, 3D-printed wall assemblies 193.7 kg CO2e/m2 from three papers, and floor or ground enclosures 164 kg CO2e/m2 from three papers. Opaque wall assemblies have the largest evidence base, with 231 rows from 52 papers. Five categories are single-paper dominant, meaning that one paper contributes at least half of their rows. These are BIPV or active facade modules, 3D-printed wall assemblies, floor or ground enclosures, render or mortar layers, and roof enclosures. Their medians are based on only a few studies and should not be read as representative of the whole literature.
Adding the 41 studies from the supplementary searches (Section 2.2) changed some category medians. The median of curtain wall systems fell from 190.3 to 136.3 kg CO2e/m2, and opaque wall assemblies rose from 37.9 to 48 because most added walls were masonry and concrete. All other categories except living walls changed by less than 5 kg CO2e/m2, so the order of the categories stayed almost the same.
Excluding the 61 rows with a per m2 value and a boundary wider than A1–A3 changed category medians by less than 2.5 kg CO2e/m2, except in two categories (Supplementary Materials, Table S3f). The BIPV median rose from 147.7 to 207 kg CO2e/m2 because three A1–A4 options from one paper were removed, and the 3D-printed wall median rose from 160.8 to 193.7 after four options were removed. These two reference ranges therefore depend on the boundary definition.
Table 5 also gives the number and median of the rows that cover a complete assembly or component product. The opaque wall assembly category includes 231 rows. Of these, 164 represent complete walls and 29 represent partial elements that exclude finishes or other wall layers. For example, the concrete layer reported by Park et al. [95] was classified as a partial element because the result did not include insulation or finishes. The remaining 38 rows represent retrofit add-ons and cover only the new layers added to existing walls. The complete-wall median (50 kg CO2e/m2) is close to the all-row median (48 kg CO2e/m2). In roof enclosures, half of the 34 rows (17) are retrofit add-ons from one paper [96]. The median of all 34 roof rows is 20.9 kg CO2e/m2. The median of the 17 complete roofs is higher, at 36.5 kg CO2e/m2.
From the 164 complete walls, 125 reported a U-value or R-value. These were grouped into four insulation bands. The median GWP was 36.8 kg CO2e/m2 for walls with a U-value at or below 0.20 W/m2K and 48.8 kg CO2e/m2 for walls between 0.20 and 0.35 W/m2K. It was 46.3 kg CO2e/m2 for walls between 0.35 and 0.60 W/m2K and 76.2 kg CO2e/m2 for walls above 0.60 W/m2K. GWP still varied widely within most bands (Supplementary Materials, Table S2d,e). Therefore, the insulation level alone did not explain the differences in GWP.
The same 164 complete walls were also grouped by their dominant material (Supplementary Materials, Table S2f). Light timber frame and timber structural insulated panel walls had a median of 14.4 kg CO2e/m2, and earth, hemp, or straw walls 25.8 kg CO2e/m2. Steel frame or metal-faced sandwich panels had a median of 58.8 kg CO2e/m2, masonry walls 72.4 kg CO2e/m2, and reinforced or precast concrete walls 86.5 kg CO2e/m2. Mass timber walls, described in only four papers, had a negative median of −68.2 kg CO2e/m2. This reflects the biogenic carbon credits applied in most of these studies, not lower fossil emissions (Section 3.5). The GWP of opaque wall assemblies should therefore be interpreted by material group, because the overall median does not represent every wall type.

3.4. Robustness to High Tail Values and Quality Stratification

The two highest values in the primary dataset came from Liu et al. [2], both for aerogel glazing (4690 and 1350 kg CO2e/m2). They were checked against the source paper and retained in the primary dataset. Without them, only the glazing or shading device median changed, from 49 to 42.5 kg CO2e/m2.
Keeping only the high confidence rows, which passed all four quality flags (Section 2.5), left 503 of the 597 rows (Table 6). In ten of the twelve categories, the median changed by 5 kg CO2e/m2 or less. The two exceptions were small categories, curtain wall systems (136.3 to 171.7 kg CO2e/m2) and living walls or green facades (64.8 to 91.1 kg CO2e/m2). Figure 5 shows the same flags for each paper. Most papers reported units, system boundaries, and separable facade results clearly, but few reported a sensitivity analysis. The high percentages in Figure 5 partly reflect the eligibility criteria, because studies with unclear units or boundaries had already been excluded at full text screening.
Table 6. Quality stratified robustness check.
Figure 5. Reporting clarity indicators of the 146 included papers. A paper meets an indicator when at least one of its options does.
Each paper was scored on six yes/no quality checks (Section 2.7). The median score was 4 out of 6, and scores ranged from 1 to 6. Almost all papers named their data source (142 of the 146 papers), and most named an LCA standard (119) and were independent of the producer of the assessed product (135). Fewer papers stated the GWP characterization method (84), a sensitivity or uncertainty analysis (57), or cut-off and allocation rules (47). Therefore, low scores mainly reflect incomplete methodological reporting rather than demonstrated bias.
To test whether study quality affected the results, the category medians were recalculated using only the papers that scored 4 or more. This kept 324 of the 597 rows, from 69 papers. Five categories changed by less than 5 kg CO2e/m2. Changes were below 2 kg CO2e/m2 for insulation, roofs, glazing, and BIPV, and below 5 kg CO2e/m2 for windows or doors. However, the median GWP for opaque walls increased from 48 to 58.8 kg CO2e/m2. Excluding papers with low-quality scores removed most low values and raised the median. In the other categories, only one to four papers remained, so their medians simply followed those papers. With a minimum score of 5, only 37 papers remained and most categories had three papers or fewer. These changes therefore show which papers remained, not a real effect of study quality. The appraisal subsets are a robustness check, not more accurate estimates.

3.5. Biogenic Carbon Handling and A1–A3 Mappability

Twenty-seven rows in the primary dataset, from 12 papers, had negative A1–A3 values, and all of them included a credit for carbon stored in bio-based materials. They were kept because a negative value is a valid result of biogenic carbon accounting, not a data error.
More than half of the 597 rows (319; 53%) contained no bio-based material, so that biogenic carbon treatment did not apply to them. The remaining 278 rows contained bio-based material; among these, 65 (23%) credited the stored carbon, 80 (29%) did not, and 133 (48%) did not report it clearly (Table 7; Figure 6). The median GWP was 9.8 kg CO2e/m2 for credited rows, 23.7 kg CO2e/m2 for not credited rows, and 55 kg CO2e/m2 for unclear rows. The median of 53.4 kg CO2e/m2 for rows without bio-based material reflects mineral and metal systems, not an accounting choice.
Table 7. Selected methodological subgroup results.
Figure 6. Biogenic carbon treatment by system type (n = number of rows). Bars show the share of rows per treatment group (not applicable, credited, not credited, not reported or unclear). Numbers inside bars are row counts.
Because these groups differ in study, material, and assembly, the gaps between their medians show an association between accounting treatment and GWP, not the effect of the credit itself. The effect of the credit can be seen only when the same option is reported both with and without it.
Such paired results were available for 27 options from 14 papers (Section 2.4; Supplementary Materials, sheet Paired Observations). One of these, a cork board, was reported only per m3; therefore, 26 options could be compared per m2. For these 26 options, the credit lowered the A1–A3 value by a median of 30.1 kg CO2e/m2 (range 1.9 to 138.4). The size of the reduction depended on how much bio-based material the option contained, because the credit equals the carbon stored in that material. It was smallest for a steel double-skin cladding system with wood fiber insulation of Gervásio et al. [97] (1.9 kg CO2e/m2) and largest for the hemp-lime wall of Rai et al. [98] (138.4 kg CO2e/m2). In 15 of the 26 options, the stored carbon was larger than the manufacturing emissions, so that the credit turned a positive value into a negative one.
Table 7 labels results reported directly as A1–A3 as “Yes, direct”, values obtained from the reported data by a simple calculation as “Yes”, and results whose boundary did not fully match A1–A3 as “Partial”. The 61 Partial rows with a per m2 value, which were not part of the primary dataset, had a higher overall median than the Yes rows, but not in every category. Most of this difference came from a few high Partial values in opaque wall assemblies, such as the stone-clad concrete walls reported by Ioannidou et al. [27], whose boundaries extended to the construction site. In BIPV or active facade modules, the Partial rows had the lower median. Being Partial therefore does not by itself explain a higher GWP.

3.6. Paper-Level Sensitivity

Some studies reported many options for the same system type, so their rows can dominate the row-level median. Each paper was therefore given one value per system type, the median of its options (Section 2.7).
Eight of the twelve categories, including the four with the most papers, changed by 5 kg CO2e/m2 or less (Table 8). Roof enclosures (+9.4) and render or mortar layers (−12.7) changed moderately, and curtain wall systems (−24.8) and 3D-printed wall assemblies (−72.2) changed most. Each of these four categories had eight papers or fewer.
Table 8. Paper-level sensitivity analysis.
The leave-one-study-out check showed the same pattern (Supplementary Materials, Paper-Level Sensitivity, Section S3). In this check, each category median was recalculated several times, each time leaving out one paper. The ranges below show the lowest and highest of these recalculated medians. In the four categories with the most papers, removing any one paper moved the median by less than 12 kg CO2e/m2. In the smaller categories, the result often depended on a single paper. The median ranged from 82 to 211.6 kg CO2e/m2 for 3D-printed walls, from 111.5 to 171.7 for curtain walls, from 26 to 84.5 for glazing or shading devices, and from 13.1 to 46.1 for render or mortar layers. BIPV or active facade modules were the exception. One paper contributed six of the eleven rows, but the other five papers reported similar values, so the median stayed between 206.5 and 208.5. The medians of the smaller categories therefore describe the few available studies rather than the literature as a whole, and they should be interpreted alongside the paper-level medians (Table 5 and Table 8; Figure 4).

4. Discussion

4.1. Principal Findings and Contribution

The embodied carbon of facades varied widely, both by system type and by how studies defined and reported their results; thus, it cannot be represented by a single value. This review makes two contributions. First, it provides facade GWP reference ranges by system type. Whole building benchmarks cannot provide these ranges because they merge facade impacts with those of other components. Second, it offers a framework for judging how reliable each comparison is. The framework considers six factors: system type, full or partial facade coverage, data quality, biogenic carbon treatment, A1–A3 boundary matching, and single-paper dominance.
The studies also show where the field is heading. Bio-based options appear in 43 of the 59 papers published from 2023 onward. They appear in only 28 of the 50 papers published between 2011 and 2019. Recent examples include hemp-lime walls, hempcrete for 3D printing, and retrofit panels made of straw, cellulose, or timber [99,100,101,102,103,104]. All six studies of 3D-printed wall elements were published between 2020 and 2025 [7,50,51,81,100,105]. Other recent studies examined kinetic facade panels, a concrete facade with integrated supercapacitors, and BIPV in deep renovation [106,107,108].
Retrofit has also become more common. Fourteen of the 59 recent papers assess retrofit or renovation, compared with 4 of the 50 earlier papers. Examples include EnerPHit retrofit scenarios in China, a deep prefabricated retrofit pilot in Canada, and advanced glazing for university building retrofits [21,102,109]. Another study compares seven over-cladding and re-cladding scenarios for university building facades in South Korea [76]. Reporting practices have changed as well. EPD data are used at least in part in 22 recent papers and 10 earlier ones. EN 15804 is cited in 25 recent papers and 18 earlier ones. Sensitivity analysis, however, remains uncommon. It is reported in 24 of the 59 recent papers and in 15 of the 50 earlier ones. These trends continue beyond our search period. A study published after the cut-off, and therefore not included in this review, compared conventional and emerging facade systems for embodied carbon and circularity [110].
Bio-based materials are not automatically low carbon. Agglomerated cork insulation was worse than common insulation materials in most impact categories, because its manufacturing used large amounts of electricity and diesel [34]. A wood fiber insulation scenario had the highest GWP of the compared renovation options [111]. In an early circular bio-based wall panel, producing and transporting materials such as straw board outweighed the sequestration benefit [29]. Emerging bio-based insulation shows the same pattern. A mycelium-bamboo composite assessed at laboratory scale had a higher wall GWP than straw, cotton stalk, cork, or kenaf insulation. It fell below them only when renewable electricity was assumed [66].
Biogenic carbon treatment can also strongly affect reported GWP. A bio-based exterior insulation panel had a 100-year GWP of 98.7 kg CO2e/m2 without carbon uptake and 7.2 kg CO2e/m2 with it [104]. In another study, dynamic modeling gave a climate impact 45% lower or 21% higher than static modeling, depending on the accounting approach [112]. Methodological studies confirm that the choice between static and dynamic accounting can strongly change the result for a bio-based product. This choice must therefore be stated for results to be comparable [113,114]. Wood fiber insulation had higher emissions than mineral wool insulation in one study because its biogenic carbon was counted as emitted in stage A1 [23]. In another study, it had the lowest embodied carbon even without sequestration [115]. These examples and the 27 paired observations in Section 3.5 show how the accounting choice changes the results for the same design.
Several studies weigh embodied carbon against other criteria, such as cost, thermal performance, operational energy, or circularity [13,15,37,116,117]. Some show clear trade-offs. A double-skin facade reduced operational carbon by 14 to 17% but increased embodied carbon by 23 to 47% [25]. In contrast, a lightweight concrete facade with multiple air gaps reduced both embodied carbon and energy use [3]. The balance depends on the energy context. In a Swedish wooden house supplied mostly by low-carbon electricity, operational energy accounted for 21% of emissions. Material production, installation, maintenance, and replacement together accounted for 67% [118]. As operational energy falls, the embodied share rises. In school buildings, embodied energy and carbon exceeded 80% of the life cycle total at the nearly zero-energy level but stayed below 15% at the cost-optimal level [5]. In UK passive houses, upfront embodied carbon was estimated to rise from about 27% to about 57% of whole-life carbon once on-site photovoltaics, battery storage, and a cleaner future grid were included [119]. Carbon payback times have also been reported for wall insulation, aerogel renders, and photovoltaic modules [35,38,48,70,120]. However, these depend on climate and operational assumptions and cannot be compared across studies.
Data sources and methodological choices can also change results and rankings. Quinn et al. [32] found that the Athena dataset gave lower results than Tally and One Click LCA for all 17 wall assemblies. Loli et al. [121] found EPD-based values about 15% lower than generic database values, except for photovoltaic products. Densley Tingley et al. and Proietti et al. [115,122] compared insulation at equal thermal performance, and Densley Tingley et al. showed that a per kilogram comparison would change the ranking. Beyond A1–A3, recycling and reuse assumptions also change the results [42,123,124].
Moreover, low GWP does not always mean low impact in other categories. Moura et al. [125] found that a cork-core concrete sandwich panel showed net carbon capture when biogenic uptake was counted, but it performed worst in six other impact categories. Similarly, Iuorio et al. [11] found that a lightweight steel wall had 63% lower GWP than a conventional masonry wall but a higher eutrophication impact.

4.2. Interpreting System Type Reference Ranges

The scope of each category matters. The low median for insulation components does not mean that a complete insulated wall has low embodied carbon, because many studies measured only the insulation layer [33,34,115,120,126]. Some rows in the assembly categories also cover only a single wall layer or the layers added in a retrofit; their effect on the medians (Table 5) is small for opaque walls but large for roofs, where half of the rows are retrofit add-ons. Therefore, a reference value should be compared only with results of similar completeness.
A GWP value per m2 also does not establish functional equivalence. Two systems with the same area can differ in thermal resistance, airtightness, structural role, service life, and durability. For example, insulation components are single layers, opaque walls vary widely in U-value, glazing and shading devices differ in light transmission and solar control, and BIPV modules, double-skin facades, and living walls provide extra functions. The medians in Table 5 do not account for these differences; they are descriptive reference ranges, not performance rankings. Several studies avoid this problem by comparing options at equal thermal performance [31,38,39]. Authors should therefore report the U-value or R-value, airtightness intent, service life, and durability assumptions next to the GWP result.
Opaque wall assemblies are included in the most observations and papers, but the category spans timber, masonry, concrete, stabilized earth, insulated composite, bio-based, and stud walls [29,32,127,128,129,130]. Its median is therefore a general reference, not a value for a specific material. The material groups in Section 3.3 show that material composition, not the opaque wall label, drives the reference value.
The curtain wall median of 136.3 kg CO2e/m2 (IQR 99.5 to 272.9 kg CO2e/m2) also depends on which studies are included. One study [25] contributes five high values, for four double-skin facades and one single-skin glazed facade. Without these, the median falls to 113.1 kg CO2e/m2 (Supplementary Materials, Paper-Level Sensitivity). The curtain wall reference range therefore covers conventional curtain walls as well as single-skin and double-skin glazed facades.
The reference ranges are most useful for early-stage screening, in which a proposed facade is compared with published results of similar system type, scope, and boundary, and the median and IQR show where the design falls. Because the ranges describe production-stage climate impacts only, operational performance, replacement, end of life effects, and other environmental impacts must be evaluated separately (Section 4.1).

4.3. Functional Unit and Boundary Comparability

The functional unit is a main barrier to comparison. Studies reported results per product, kilogram, cubic meter, module, kWp or kWh of generated electricity, building, or floor area, whereas our preferred basis was kg CO2e/m2 of facade, wall, glazing, or enclosure area. When a paper reports neither the facade area nor a clear declared unit, its result cannot be converted to per m2 without assumptions. This, together with the strict A1–A3 boundary rule, explains why the primary dataset contains only 597 of the 800 extracted options.
Boundary comparability matters just as much. Some papers combine A1–A3 with transport, installation, or later life cycle stages; their results therefore cannot be compared with cradle-to-gate values. In lime-based walls, the carbon dioxide that the binder re-absorbs during use (carbonation, module B1) was reported separately in some studies [84,99,131] but included in the product-stage result in others [64,66,100], which were therefore treated as Partial (Section 2.1).

4.4. Hotspot Interpretation

The category medians show how much embodied carbon each system type carries, but not where it comes from. The studies identified hotspots at different levels, such as material, process, component, or life cycle module; these are therefore discussed by type rather than counted.
Material-level hotspots were the main mass or finish of the system. Aluminum framing and glass dominated the impacts of aluminum curtain walls [22]. Alternatives to aluminum performed better. A wood-based curtain wall had a lower production-stage GWP than an aluminum-framed one [1], and ceramic cladding panels had lower impacts than aluminum panels [132]. Among seven facade finishes, a ventilated render facade on aluminum profiles ranked highest in life cycle GWP [131]. In concrete sandwich panels, Portland cement accounted for more than half of the concrete mix impacts [125]. Concrete for 3D printing requires more cement, so that 3D-printed walls had higher emissions than a conventional reinforced concrete wall [51]. Foam insulation was another material hotspot, mainly because of raw material production [33]. The main mass is not always the visible material. In stone-clad walls, for example, the concrete substructure dominated GWP, not the stone panel [27].
A component with little mass can also carry much of the embodied carbon. Polyurethane, for example, made up 1.86% of material mass but 13.33% of embodied carbon [6], and copper wiring accounted for 32% of the GWP of a kinetic facade prototype [106]. At the process level, energy-intensive production steps were the main hotspots. In ceramic panels, for example, the natural gas burned for drying and firing was the largest contributor to GWP [41]. Manufacturing energy was also a hotspot for new products. In one scenario of the source study, replacing the Portuguese electricity grid with the Norwegian grid cut the product-stage GWP of a composite sandwich panel from 169 to 66 kg CO2e/m2 [133]. For aerogel glazing, the drying process was the hotspot, and its size depended strongly on production scale. The glazing investigated by Liu et al. [2] gave 4690 kg CO2e/m2 with bench-scale supercritical drying but 83 kg CO2e/m2 in commercial production, a more than fifty-fold difference (Section 3.4). At the component level, one component or group of components was often the largest contributor in active and multifunctional facades. Examples include photovoltaic (PV) cells in a photovoltaic-thermal module [134] and the supercapacitor components in an energy-storing concrete facade [107]. At the life cycle module level, raw material supply (A1) was the largest contributor in all three prefabricated facade systems reported by Morganti et al. [23], because they contained many complex components. The authors also noted that their transport impacts (A2 and A4) were probably higher than in a typical supply chain, because the suppliers were spread across Europe.
These hotspot types call for different design responses, such as less or lower-carbon material, cleaner manufacturing energy, redesign of a single component, or local sourcing. Future studies should therefore report hotspots within one hierarchy, from the life cycle module (A1, A2, A3) to the component, the process, and the material, and studies of prototypes and emerging products should state which scale their values represent.

4.5. Implications for Future Facade LCA Reporting

Table 9 turns these comparability problems into a reporting checklist of facade-specific information that LCA studies often omit, namely facade area, layer-by-layer composition, module separation, system scope, performance equivalence, biogenic treatment, data sources, and the level at which hotspots are reported.
Table 9. Minimum reporting checklist for comparable facade and enclosure LCA studies.
The checklist can guide authors and practitioners when they report LCA results, and it can help reviewers and journal editors check whether a study reports the information needed for comparison. Two results can be compared only if they match in unit, boundary, scope, layer composition, and performance (Table 9). Otherwise, they must first be adjusted or not compared at all. The same applies to the reference ranges in Table 5, which should be compared only with results that have the same unit, boundary, and scope.
To make such checks possible, every study should report at least four items. These are the original functional unit together with the normalized kg CO2e/m2 value and the area used for it; a statement of system completeness (complete assembly or partial component); the treatment of biogenic carbon, including not applicable; and at least one sensitivity analysis. In this review, results that lacked these items had to be excluded or reported with caveats. For example, 138 of the 800 options (17%) had no comparable per m2 value, biogenic treatment was unclear for 48% of the options with bio-based material, and 61% of the included papers reported no sensitivity or uncertainty analysis (Section 3.4). Each issue corresponds to an item in Table 9; the checklist therefore rests on problems found here rather than on general advice.

5. Limitations

Because Scopus was not available, Web of Science, Lens.org, and backward citation tracking were used to widen the search. However, studies indexed only in Scopus and not cited by any included study could still have been missed. ScienceDirect provided 76% of the records from the January search because it searches the full text of articles. This did not limit the review to Elsevier publications, because 58 of the 146 included studies, including 30 of the 41 added studies, came from other publishers. Citation tracking followed DOIs backward only; references without a DOI therefore could not be traced, and no forward citation search was done. Only English-language studies were eligible, and the supplementary searches were limited to publications up to 12 January 2026.
The evidence is uneven across system types. The reference ranges should be judged by how many studies support them and how evenly the options are spread across those studies, not by the number of extracted options. Five categories are dominated by a single study. In the paper-level analysis, the medians of 3D-printed walls and curtain walls decreased by 72 and 25 kg CO2e/m2, compared with changes of less than 4 kg CO2e/m2 in categories with ten or more studies. For categories with few studies, the median describes the available studies rather than the literature as a whole. It should therefore be read together with the paper-level median (Table 5) and the leave-one-study-out range (Section 3.6).
The included studies differ in system scope, data source, software, standard, location, and reporting; therefore, no meta-analysis was attempted. The descriptive medians and ranges are also not adjusted for thermal performance, structural role, or service life (Section 4.2). Even within the same U-value band, the GWP of complete opaque walls still varied widely (Section 3.3). Differences within a category may therefore reflect different performance requirements rather than differences in carbon efficiency.
The strict A1–A3 rule excluded 65 options from 15 studies (61 with a per m2 value) whose results could not be separated into A1–A3. These were used only in the boundary sensitivity analysis and the A1–A3 mappability comparison. Adding them back changed most category medians by less than 2.5 kg CO2e/m2, with two exceptions. The BIPV median fell from 207 to 147.7 kg CO2e/m2 because of three A1–A4 options from one study, and the 3D-printed wall median fell from 193.7 to 160.8 kg CO2e/m2 because of four A1–A4 or carbonation-inclusive options from two studies. These two reference ranges are therefore particularly sensitive to the boundary definition.
Biogenic carbon treatment had to be assigned by judgment when a study described it only indirectly, and 133 of the 278 bio-relevant options could only be classified as “not reported or unclear” because the studies gave no information. Only the 27 paired observations compare the same option with and without the credit, and these are too few to separate the effect of the accounting method from the effect of material differences across the whole dataset.
The high confidence flags measure only reporting clarity, and their high pass rates (Figure 5) partly reflect the screening criteria (Section 3.4). The six-check appraisal goes further, but it remains semi-formal because no validated risk-of-bias tool exists for LCA studies. The authors chose the checks and weighted them equally. The checks record whether a method element was stated and whether the study was independent of the producer, but not whether the result is correct. The certainty of the evidence was also not graded.
Hotspots were described through examples rather than counted, because studies reported them at different levels (Section 4.4). A hotspot summary for each option is given in the Supplementary Materials. Finally, the review covers only one impact category, GWP, because this was the only one reported consistently across the studies (Section 4.1).

6. Conclusions

This review considered 800 facade and enclosure options from 146 studies and compared the 597 options from 111 studies that report strict A1–A3 results per square meter. Median GWP ranged from 9.1 kg CO2e/m2 for insulation components to 207 kg CO2e/m2 for BIPV or active facade modules. Opaque wall assemblies formed the largest evidence base, with 231 options from 52 studies and a median of 48 kg CO2e/m2. Their GWP differed more between dominant materials than between insulation levels. Two thirds of the studies were published from 2020 onward; so, the ranges will change as the field grows.
The main result of the sensitivity analyses is that a reference range can be trusted according to how many studies support it and how evenly its options are spread across those studies, not according to how many options it contains. When each study was given one value, the medians of the four categories with the most studies changed by less than 4 kg CO2e/m2. When each study was left out in turn, a single study could shift the median of small categories, such as 3D-printed walls, curtain walls, glazing, and render, by up to 112 kg CO2e/m2. Excluding the two extreme values or keeping only high confidence rows changed most medians by only a few kg CO2e/m2. Adding back the options with a wider boundary changed most medians by less than 2.5 kg CO2e/m2, but the BIPV and 3D-printed wall medians fell by about 59 and 33 kg CO2e/m2; these two values depended on the boundary rule. Keeping only the higher-scoring studies changed some medians, but mainly because few studies remained in the small categories, not because of a clear effect of study quality. Overall, the large categories remained broadly consistent across these tests and can serve as descriptive reference ranges. The smaller categories describe only the few available studies, so their values should always be cited together with the number of studies behind them.
Reporting, rather than any facade technology, was the main reason options could not be compared. One-quarter of the extracted options could not be expressed per square meter with a strict A1–A3 boundary, and the biogenic carbon treatment was unclear or unreported for 48% of the options with bio-based material. Options that credited biogenic carbon had a lower median than those that did not. Because the two groups also differed in materials and designs, this difference is an association rather than the effect of the accounting choice. However, the 27 paired observations show that the credit alone can turn a positive result into a negative one.
Across the studies, aluminum, glass, cement-based materials, and foam insulation were the recurring material hotspots, and manufacturing energy was a further one. Low-mass components can matter more than their mass suggests, and bio-based options are not automatically low-carbon. Accounting choices for biogenic carbon, electricity, service life, and end of life can also change both values and rankings. Recent studies more often assess bio-based, retrofit, and 3D-printed systems and more often use EPD data, yet 61% of all included studies still report no sensitivity or uncertainty analysis of the carbon result.
The reference ranges can support early design screening, but they are not fixed targets. A high value should therefore lead designers to examine the facade’s materials and components, not to conclude that one facade type is better than another. Such comparisons are only meaningful when results are reported in the same way, and Table 9 sets out what this requires. For each result, authors should report the original unit, the normalized value, and the area used for normalization. They should also state what the result covers (system scope, layer composition, and life cycle modules) and how it was calculated (data sources, performance assumptions, and biogenic carbon treatment, including “not applicable”), and they should include at least one sensitivity analysis. Consistent reporting of these items would make facade LCA results easier to compare and more useful for design decisions.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/buildings16214219/s1, File S1: Supplementary Material workbook with the worksheets Read Me, Data Dictionary, Controlled Vocabulary, Search Strategy (Table S1: all searches of the review and the recall test), Extraction Data, Papers Summary, Study Appraisal (Table S4a: semi-formal appraisal of the 146 included papers, Table S4b: distribution of appraisal scores and frequency of each check, Table S4c: category medians by appraisal score), Paired Observations, Descriptive Statistics (Table S2a: descriptive statistics by system type, Table S2b: single-paper dominance diagnostic, Table S2c: high-confidence subset vs. primary subset, Table S2d: scope completeness by system type, Table S2e: complete opaque walls by U-value band, Table S2f: complete opaque walls by dominant material class, Table S2g: options outside the primary dataset by system type and reason), Methodological Subgroups (Table S3a: normalized GWP by biogenic carbon treatment, Table S3b: biogenic carbon treatment within bio-relevant system types, Table S3c: biogenic carbon treatment by system type, Table S3d: normalized GWP by A1–A3 mappability, Table S3e: A1–A3 mappability by system type, Table S3f: boundary sensitivity), and Paper-Level Sensitivity; File S2: PRISMA 2020 checklist. References [95,96,98,137,138,139,140,141,142,143,144,145,146,147,148,149,150,151,152,153,154,155,156,157,158,159,160,161,162,163,164,165,166,167,168] are cited in the Supplementary Materials.

Author Contributions

Conceptualization, S.M. and T.M.; methodology, S.M. and T.M.; software, S.M. and A.M.S.; validation, S.M., A.M.S., M.H. (Mahboobeh Hemmati) and M.H. (Moein Hemmati); formal analysis, S.M. and A.M.S.; investigation, S.M., A.M.S., M.H. (Mahboobeh Hemmati) and M.H. (Moein Hemmati); resources, S.M.; data curation, S.M. and A.M.S.; writing—original draft preparation, S.M.; writing—review and editing, S.M., T.M., A.M.S., M.H. (Mahboobeh Hemmati) and M.H. (Moein Hemmati); visualization, S.M.; supervision, T.M.; project administration, S.M. and T.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding. The APC was funded in part by the Open Access Publishing Fund administered through the University of Arkansas Libraries.

Data Availability Statement

The original contributions presented in this study are included in the article/Supplementary Materials. The R code used to create the figures is available from the corresponding author on request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

BIPVBuilding-integrated photovoltaic
EPDEnvironmental Product Declaration
GWPGlobal warming potential
IQRInterquartile range
LCALife cycle assessment
PRISMAPreferred Reporting Items for Systematic Reviews and Meta-Analyses
PVPhotovoltaic

References

  1. Volf, M.; Lupíšek, A.; Bureš, M.; Nováček, J.; Hejtmánek, P.; Tywoniak, J. Application of Building Design Strategies to Create an Environmentally Friendly Building Envelope for Nearly Zero-Energy Buildings in the Central European Climate. Energy Build. 2018, 165, 35–46. [Google Scholar] [CrossRef] [Scilit]
  2. Liu, Y.; Yan, J.; Hu, Z.; Chen, Y.; Lv, L. Evaluation the Life Cycle Carbon Emissions of the Aerogel Glazing under Different Weather Conditions. J. Clean. Prod. 2024, 437, 140651. [Google Scholar] [CrossRef] [Scilit]
  3. Shao, Y.; Parks, A.; Ostertag, C.P. Lightweight Concrete Façade with Multiple Air Gaps for Sustainable and Energy-Efficient Buildings in Singapore. Build. Environ. 2022, 223, 109463. [Google Scholar] [CrossRef] [Scilit]
  4. Meneghelli, A. Whole-Building Embodied Carbon of a North American LEED-Certified Library: Sensitivity Analysis of the Environmental Impact of Buildings Materials. Build. Environ. 2018, 134, 230–241. [Google Scholar] [CrossRef] [Scilit]
  5. Moazzen, N.; Karagüler, M.E.; Ashrafian, T. Comprehensive Parameters for the Definition of Nearly Zero Energy and Cost Optimal Levels Considering the Life Cycle Energy and Thermal Comfort of School Buildings. Energy Build. 2021, 253, 111487. [Google Scholar] [CrossRef] [Scilit]
  6. Rodríguez, L.; Martínez, L.; Panameño, R.; París, O.; Muros, A.; Rodríguez, R.; Javier, R.; González, C. LCA of the NZEB El Salvador Building, a Model to Estimate the Carbon Footprint in a Tropical Country. J. Clean. Prod. 2023, 408, 137137. [Google Scholar] [CrossRef] [Scilit]
  7. Taylor, C.; Roy, K.; Dani, A.A.; Lim, J.B.P.; De Silva, K.; Jones, M. Delivering Sustainable Housing through Material Choice. Sustainability 2023, 15, 3331. [Google Scholar] [CrossRef] [Scilit]
  8. Idrissi Kaitouni, S.; Gargab, F.-Z.; Tabit, A.; Mabrouki, M.; Lamdouar, N.; Jamil, A.; Ahachad, M. A Life Cycle Carbon Dioxide Equivalent Emissions Assessment of Zero Carbon Building in Hot Semi-Arid Climate Region: Case Study. Results Eng. 2024, 23, 102589. [Google Scholar] [CrossRef] [Scilit]
  9. Božiček, D.; Kunič, R.; Košir, M. Interpreting Environmental Impacts in Building Design: Application of a Comparative Assertion Method in the Context of the EPD Scheme for Building Products. J. Clean. Prod. 2021, 279, 123399. [Google Scholar] [CrossRef] [Scilit]
  10. Fufa, S.M.; Skaar, C.; Gradeci, K.; Labonnote, N. Assessment of Greenhouse Gas Emissions of Ventilated Timber Wall Constructions Based on Parametric LCA. J. Clean. Prod. 2018, 197, 34–46. [Google Scholar] [CrossRef] [Scilit]
  11. Iuorio, O.; Napolano, L.; Fiorino, L.; Landolfo, R. The Environmental Impacts of an Innovative Modular Lightweight Steel System: The Elissa Case. J. Clean. Prod. 2019, 238, 117905. [Google Scholar] [CrossRef] [Scilit]
  12. Leskovar, V.Ž.; Žigart, M.; Premrov, M.; Lukman, R.K. Comparative Assessment of Shape Related Cross-Laminated Timber Building Typologies Focusing on Environmental Performance. J. Clean. Prod. 2019, 216, 482–494. [Google Scholar] [CrossRef] [Scilit]
  13. Tushar, Q.; Bhuiyan, M.A.; Zhang, G. Energy Simulation and Modeling for Window System: A Comparative Study of Life Cycle Assessment and Life Cycle Costing. J. Clean. Prod. 2022, 330, 129936. [Google Scholar] [CrossRef] [Scilit]
  14. Baldassarri, C.; Shehabi, A.; Asdrubali, F.; Masanet, E. Energy and Emissions Analysis of next Generation Electrochromic Devices. Sol. Energy Mater. Sol. Cells 2016, 156, 170–181. [Google Scholar] [CrossRef] [Scilit]
  15. Taghizade, K.; Heidari, A.; Noorzai, E. Environmental Impact Profiles for Glazing Systems: Strategies for Early Design Process. J. Archit. Eng. 2019, 25, 04019005. [Google Scholar] [CrossRef] [Scilit]
  16. Búryová, D.; Vaňová, R.; Gregor, M.; Uhrín, R.; Sedlák, P. Life Cycle Perspectives of Fixed and Operable Wooden Windows. Buildings 2025, 15, 4490. [Google Scholar] [CrossRef] [Scilit]
  17. Kowalczyk, Z.; Twardowski, S.; Malinowski, M.; Kuboń, M. Life Cycle Assessment (LCA) and Energy Assessment of the Production and Use of Windows in Residential Buildings. Sci. Rep. 2023, 13, 19752. [Google Scholar] [CrossRef] [Scilit]
  18. Marinello Jorba, V.; Palumbo, E.; Del Rosario, P.; Traverso, M. Interpreting Environmental Impacts of Wooden Windows Based on Existing EPDs: An Application in Italy. Energy Build. 2025, 326, 114987. [Google Scholar] [CrossRef] [Scilit]
  19. Agliata, R.; Di Giuseppe, E.; Favi, C.; Munafò, P. Technical and Environmental Analysis of an Innovative Window Concept Based on a Hidden Frame: Insights from a Life Cycle Perspective. J. Clean. Prod. 2024, 485, 144424. [Google Scholar] [CrossRef] [Scilit]
  20. Sällström Eriksson, L.; Lidelöw, S. A Comparative Life Cycle Study of Window Interventions: Impact of Building Characteristics and Local Context. J. Build. Eng. 2025, 111, 113019. [Google Scholar] [CrossRef] [Scilit]
  21. Karimian, S.; Azmoodeh, M.; Dokhanian, F.; Mohajerani, M. Advanced Glazing Systems for Retrofitting Educational Buildings: A Comprehensive Visual Comfort, Life Cycle Energy, and Environmental Impact. Build. Environ. 2026, 287, 113785. [Google Scholar] [CrossRef] [Scilit]
  22. Cheong, C.Y.; Brambilla, A.; Gasparri, E.; Kuru, A.; Sangiorgio, A. Life Cycle Assessment of Curtain Wall Facades: A Screening Study on End-of-Life Scenarios. J. Build. Eng. 2024, 84, 108600. [Google Scholar] [CrossRef] [Scilit]
  23. Morganti, L.; Vandi, L.; Astudillo Larraz, J.; García-Jaca, J.; Navarro Muedra, A.; Pracucci, A. A1–A5 Embodied Carbon Assessment to Evaluate Bio-Based Components in Façade System Modules. Sustainability 2024, 16, 1190. [Google Scholar] [CrossRef] [Scilit]
  24. Hay, R.; Ostertag, C.P. Life Cycle Assessment (LCA) of Double-Skin Façade (DSF) System with Fiber-Reinforced Concrete for Sustainable and Energy-Efficient Buildings in the Tropics. Build. Environ. 2018, 142, 327–341. [Google Scholar] [CrossRef] [Scilit]
  25. Zomorodian, Z.S.; Tahsildoost, M. Energy and Carbon Analysis of Double Skin Façades in the Hot and Dry Climate. J. Clean. Prod. 2018, 197, 85–96. [Google Scholar] [CrossRef] [Scilit]
  26. Larivière-Lajoie, R.; Blanchet, P.; Amor, B. Evaluating the Importance of the Embodied Impacts of Wall Assemblies in the Context of a Low Environmental Impact Energy Mix. Build. Environ. 2021, 207, 108534. [Google Scholar] [CrossRef] [Scilit]
  27. Ioannidou, D.; Zerbi, S.; Habert, G. When More Is Better—Comparative LCA of Wall Systems with Stone. Build. Environ. 2014, 82, 628–639. [Google Scholar] [CrossRef] [Scilit]
  28. Ben-Alon, L.; Loftness, V.; Harries, K.A.; Cochran Hameen, E. Life Cycle Assessment (LCA) of Natural vs Conventional Building Assemblies. Renew. Sustain. Energy Rev. 2021, 144, 110951. [Google Scholar] [CrossRef] [Scilit]
  29. Cascione, V.; Roberts, M.; Allen, S.; Dams, B.; Maskell, D.; Shea, A.; Walker, P.; Emmitt, S. Integration of Life Cycle Assessments (LCA) in Circular Bio-Based Wall Panel Design. J. Clean. Prod. 2022, 344, 130938. [Google Scholar] [CrossRef] [Scilit]
  30. Ben-Alon, L.; Loftness, V.; Harries, K.A.; DiPietro, G.; Hameen, E.C. Cradle to Site Life Cycle Assessment (LCA) of Natural vs Conventional Building Materials: A Case Study on Cob Earthen Material. Build. Environ. 2019, 160, 106150. [Google Scholar] [CrossRef] [Scilit]
  31. Giuffrida, G.; Dipasquale, L.; Pulselli, R.M.; Caponetto, R. Compared Environmental Lifecycle Performances of Earth-Based Walls to Drive Building Envelope Design. Sustainability 2024, 16, 1367. [Google Scholar] [CrossRef] [Scilit]
  32. Quinn, M.S.; Jungclaus, M.A.; Broyles, J.M.; Srubar, W.V. A Multi-Objective Performance Assessment of Prototypical Residential Wall Assemblies in the United States. Energy Build. 2025, 347, 116385. [Google Scholar] [CrossRef] [Scilit]
  33. Pargana, N.; Pinheiro, M.D.; Silvestre, J.D.; De Brito, J. Comparative Environmental Life Cycle Assessment of Thermal Insulation Materials of Buildings. Energy Build. 2014, 82, 466–481. [Google Scholar] [CrossRef] [Scilit]
  34. Sierra-Pérez, J.; Boschmonart-Rives, J.; Dias, A.C.; Gabarrell, X. Environmental Implications of the Use of Agglomerated Cork as Thermal Insulation in Buildings. J. Clean. Prod. 2016, 126, 97–107. [Google Scholar] [CrossRef] [Scilit]
  35. Pedroso, M.; Silvestre, J.D.; Flores-Colen, I.; Gomes, M.G. Environmental Impact of Wall Multilayer Coating Systems Containing Aerogel-Based Fibre-Enhanced Thermal Renders. J. Build. Eng. 2023, 76, 107322. [Google Scholar] [CrossRef] [Scilit]
  36. Zhilyaev, D.; Fachinotti, V.D.; Zanoni, F.; Ortega, A.; Goracci, G.; Mankel, C.; Koenders, E.A.B.; Jonkers, H.M. Early-Stage Analysis of a Novel Insulation Material Based on MPCM-Doped Cementitious Foam: Modelling of Properties, Identification of Production Process Hotspots and Exploration of Performance Trade-Offs. Dev. Built Environ. 2023, 16, 100243. [Google Scholar] [CrossRef] [Scilit]
  37. Zabek, M.; Galvez-Martos, J.-L.; Konstantinou, T. Carbon Flow Analysis: A Novel Approach for Circularity Evaluation of Façade Components. Clean. Environ. Syst. 2025, 19, 100361. [Google Scholar] [CrossRef] [Scilit]
  38. Kunič, R. Carbon Footprint of Thermal Insulation Materials in Building Envelopes. Energy Effic. 2017, 10, 1511–1528. [Google Scholar] [CrossRef] [Scilit]
  39. Resalati, S.; Okoroafor, T.; Henshall, P.; Simões, N.; Gonçalves, M.; Alam, M. Comparative Life Cycle Assessment of Different Vacuum Insulation Panel Core Materials Using a Cradle to Gate Approach. Build. Environ. 2021, 188, 107501. [Google Scholar] [CrossRef] [Scilit]
  40. Alsaqabi, Y.; Almhafdy, A.; Haider, H.; Ghaffarianhoseini, A.; Ghaffarianhoseini, A.; Ali, A.A.M. Techno-Environmental Assessment of Insulation Materials in Saudi Arabia: Integrating Thermal Performance and LCA. Buildings 2023, 13, 331. [Google Scholar] [CrossRef] [Scilit]
  41. Han, B.; Wang, R.; Yao, L.; Liu, H.; Wang, Z. Life Cycle Assessment of Ceramic Façade Material and Its Comparative Analysis with Three Other Common Façade Materials. J. Clean. Prod. 2015, 99, 86–93. [Google Scholar] [CrossRef] [Scilit]
  42. Roy, K.; Su, R.; Dani, A.A.; Fang, Z.; Liang, H.; Lim, J.B.P. Spatiotemporal Model to Quantify Stocks of Metal Cladding Products for a Prospective Circular Economy. Appl. Sci. 2022, 12, 4597. [Google Scholar] [CrossRef] [Scilit]
  43. Hartwell, R.; Overend, M. Reclamation Potential in the Built Environment: A Method and Metric for Assessing Environmental Benefits beyond First Use. Build. Environ. 2024, 263, 111866. [Google Scholar] [CrossRef] [Scilit]
  44. Búryová, D.; Sedlák, P. Life Cycle Assessment of Coated and Thermally Modified Wood Façades. Coatings 2021, 11, 1487. [Google Scholar] [CrossRef] [Scilit]
  45. Popp, C.; Uhlig, C.; Engelmann, M. Prospective Life Cycle Analysis of a BIPV Façade—Life Cycle Assessment of Greenhouse Gas Emissions Using Future Projections for a Case Study. Energy Build. 2025, 330, 115336. [Google Scholar] [CrossRef] [Scilit]
  46. Belussi, L.; Mariotto, M.; Meroni, I.; Zevi, C.; Svaldi, S.D. LCA Study and Testing of a Photovoltaic Ceramic Tile Prototype. Renew. Energy 2015, 74, 263–270. [Google Scholar] [CrossRef] [Scilit]
  47. Lamnatou, C.; Baig, H.; Chemisana, D.; Mallick, T.K. Dielectric-Based 3D Building-Integrated Concentrating Photovoltaic Modules: An Environmental Life-Cycle Assessment. Energy Build. 2017, 138, 514–525. [Google Scholar] [CrossRef] [Scilit]
  48. Li, Z.; Zhang, W.; He, B.; Xie, L.; Chen, M.; Li, J.; Zhao, O.; Wu, X. A Comprehensive Life Cycle Assessment Study of Innovative Bifacial Photovoltaic Applied on Building. Energy 2022, 245, 123212. [Google Scholar] [CrossRef] [Scilit]
  49. Fan, W.; Zhang, J.; Zhou, J.; Li, C.; Hu, J.; Hu, F.; Nie, Z. LCA and Scenario Analysis of Building Carbon Emission Reduction: The Influencing Factors of the Carbon Emission of a Photovoltaic Curtain Wall. Energies 2023, 16, 4501. [Google Scholar] [CrossRef] [Scilit]
  50. Bianchi, I.; Volpe, S.; Fiorito, F.; Forcellese, A.; Sangiorgio, V. Life Cycle Assessment of Building Envelopes Manufactured through Different 3D Printing Technologies. J. Clean. Prod. 2024, 440, 140905. [Google Scholar] [CrossRef] [Scilit]
  51. Ramesh, A.; Navaratnam, S.; Rajeev, P.; Sanjayan, J. Thermal Performance and Life Cycle Analysis of 3D Printed Concrete Wall Building. Energy Build. 2024, 320, 114604. [Google Scholar] [CrossRef] [Scilit]
  52. Serra, V.; Bianco, L.; Candelari, E.; Giordano, R.; Montacchini, E.; Tedesco, S.; Larcher, F.; Schiavi, A. A Novel Vertical Greenery Module System for Building Envelopes: The Results and Outcomes of a Multidisciplinary Research Project. Energy Build. 2017, 146, 333–352. [Google Scholar] [CrossRef] [Scilit]
  53. Solera Jimenez, M.; Cortesão, J.; Lenzholzer, S.; Walker, R. Early-Stage Design of a Low-Embodied Carbon and Cost-Effective Green Facade System. J. Build. Eng. 2023, 72, 106588. [Google Scholar] [CrossRef] [Scilit]
  54. Shi, Y.; Cao, X.; Yang, X. Assessment and Reduction of Embodied Carbon Emissions in Buildings: A Systematic Literature Review of Recent Advances. Energy Build. 2025, 345, 116058. [Google Scholar] [CrossRef] [Scilit]
  55. Minunno, R.; O’Grady, T.; Morrison, G.M.; Gruner, R.L. Investigating the Embodied Energy and Carbon of Buildings: A Systematic Literature Review and Meta-Analysis of Life Cycle Assessments. Renew. Sustain. Energy Rev. 2021, 143, 110935. [Google Scholar] [CrossRef] [Scilit]
  56. Kumar, D.; Alam, M.; Memon, R.A.; Bhayo, B.A. A Critical Review for Formulation and Conceptualization of an Ideal Building Envelope and Novel Sustainability Framework for Building Applications. Clean. Eng. Technol. 2022, 11, 100555. [Google Scholar] [CrossRef] [Scilit]
  57. Kitsopoulou, A.; Bellos, E.; Tzivanidis, C. An Up-to-Date Review of Passive Building Envelope Technologies for Sustainable Design. Energies 2024, 17, 4039. [Google Scholar] [CrossRef] [Scilit]
  58. Attia, S.; Lioure, R.; Declaude, Q. Future Trends and Main Concepts of Adaptive Facade Systems. Energy Sci. Eng. 2020, 8, 3255–3272. [Google Scholar] [CrossRef] [Scilit]
  59. Vilches, A.; Garcia-Martinez, A.; Sanchez-Montañes, B. Life Cycle Assessment (LCA) of Building Refurbishment: A Literature Review. Energy Build. 2017, 135, 286–301. [Google Scholar] [CrossRef] [Scilit]
  60. Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 Statement: An Updated Guideline for Reporting Systematic Reviews. BMJ 2021, 372, n71. [Google Scholar] [CrossRef] [Scilit]
  61. Rethlefsen, M.L.; Kirtley, S.; Waffenschmidt, S.; Ayala, A.P.; Moher, D.; Page, M.J.; Koffel, J.B.; PRISMA-S Group; Blunt, H.; Brigham, T.; et al. PRISMA-S: An Extension to the PRISMA Statement for Reporting Literature Searches in Systematic Reviews. Syst. Rev. 2021, 10, 39. [Google Scholar] [CrossRef] [Scilit]
  62. EN 15804:2012+A2:2019; Sustainability of Construction Works—Environmental Product Declarations—Core Rules for the Product Category of Construction Products. European Committee for Standardization CEN: Brussels, Belgium, 2019.
  63. Alfraidi, S.; Abdallah, A.S.H.; Aldersoni, A.; Abdelhafez, M.H.H.; Aldamady, A.A.; Ragab, A. Evaluating the Energy and Carbon Performance of Advanced Glazing Systems for Hot–Arid Climates: An Integrated Simulation and LCA Approach. Buildings 2025, 15, 4283. [Google Scholar] [CrossRef] [Scilit]
  64. Arrigoni, A.; Pelosato, R.; Melià, P.; Ruggieri, G.; Sabbadini, S.; Dotelli, G. Life Cycle Assessment of Natural Building Materials: The Role of Carbonation, Mixture Components and Transport in the Environmental Impacts of Hempcrete Blocks. J. Clean. Prod. 2017, 149, 1051–1061. [Google Scholar] [CrossRef] [Scilit]
  65. Asdrubali, F.; Grazieschi, G.; Roncone, M.; Thiebat, F.; Carbonaro, C. Sustainability of Building Materials: Embodied Energy and Embodied Carbon of Masonry. Energies 2023, 16, 1846. [Google Scholar] [CrossRef] [Scilit]
  66. Carcassi, O.B.; Minotti, P.; Habert, G.; Paoletti, I.; Claude, S.; Pittau, F. Carbon Footprint Assessment of a Novel Bio-Based Composite for Building Insulation. Sustainability 2022, 14, 1384. [Google Scholar] [CrossRef] [Scilit]
  67. Chàfer, M.; Pérez, G.; Coma, J.; Cabeza, L.F. A Comparative Life Cycle Assessment between Green Walls and Green Facades in the Mediterranean Continental Climate. Energy Build. 2021, 249, 111236. [Google Scholar] [CrossRef] [Scilit]
  68. Di Giuseppe, E.; D’Orazio, M.; Du, G.; Favi, C.; Lasvaux, S.; Maracchini, G.; Padey, P. A Stochastic Approach to LCA of Internal Insulation Solutions for Historic Buildings. Sustainability 2020, 12, 1535. [Google Scholar] [CrossRef] [Scilit]
  69. Galán-Marín, C.; Martínez-Rocamora, A.; Solís-Guzmán, J.; Rivera-Gómez, C. Natural Stabilized Earth Panels versus Conventional Façade Systems. Economic and Environmental Impact Assessment. Sustainability 2018, 10, 1020. [Google Scholar] [CrossRef] [Scilit]
  70. Gigasari, A.R.; Cárcel-Carrasco, J.; Palmero Iglesias, L.M.; Amani, N. Evaluating Carbon Payback Time by Optimizing Insulation Materials for Different Orientations: A Cradle-to-Gate Life Cycle Assessment. Energy Environ. 2025, 36, 1290–1308. [Google Scholar] [CrossRef] [Scilit]
  71. Gomes, R.; Silvestre, J.D.; De Brito, J. Environmental Life Cycle Assessment of Thermal Insulation Tiles for Flat Roofs. Materials 2019, 12, 2595. [Google Scholar] [CrossRef] [Scilit]
  72. González-García, S.; Lozano, R.G.; Estévez, J.C.; Pascual, R.C.; Moreira, M.T.; Gabarrell, X.; I Pons, J.R.; Feijoo, G. Environmental Assessment and Improvement Alternatives of a Ventilated Wooden Wall from LCA and DfE Perspective. Int. J. Life Cycle Assess. 2012, 17, 432–443. [Google Scholar] [CrossRef] [Scilit]
  73. Intini, F.; Rospi, G.; Cardinale, N.; Kühtz, S.; Dassisti, M. Life Cycle Assessment of Italian Residential Windows: Sensitivity of Analysis. Int. J. Heat Technol. 2016, 34, S235–S241. [Google Scholar] [CrossRef] [Scilit]
  74. Ip, K.; Miller, A. Life Cycle Greenhouse Gas Emissions of Hemp–Lime Wall Constructions in the UK. Resour. Conserv. Recycl. 2012, 69, 1–9. [Google Scholar] [CrossRef] [Scilit]
  75. La Rosa, A.D.; Recca, A.; Gagliano, A.; Summerscales, J.; Latteri, A.; Cozzo, G.; Cicala, G. Environmental Impacts and Thermal Insulation Performance of Innovative Composite Solutions for Building Applications. Constr. Build. Mater. 2014, 55, 406–414. [Google Scholar] [CrossRef] [Scilit]
  76. Liu, J.; Won, C. Assessing the Impact of Façade Typologies on Life Cycle Embodied Carbon in University Building Retrofits: A Case Study of South Korea. Sustainability 2024, 16, 8901. [Google Scholar] [CrossRef] [Scilit]
  77. Llorach-Massana, P.; Cirrincione, L.; Sierra-Perez, J.; Scaccianoce, G.; La Gennusa, M.; Peña, J.; Rieradevall, J. Environmental Assessment of a New Building Envelope Material Derived from Urban Agriculture Wastes: The Case of the Tomato Plants Stems. Int. J. Life Cycle Assess. 2023, 28, 813–827. [Google Scholar] [CrossRef] [Scilit]
  78. Mazor, M.H.; Mutton, J.D.; Russell, D.A.M.; Keoleian, G.A. Life Cycle Greenhouse Gas Emissions Reduction From Rigid Thermal Insulation Use in Buildings. J. Ind. Ecol. 2011, 15, 284–299. [Google Scholar] [CrossRef] [Scilit]
  79. Michałowski, B.; Marcinek, M.; Tomaszewska, J.; Czernik, S.; Piasecki, M.; Geryło, R.; Michalak, J. Influence of Rendering Type on the Environmental Characteristics of Expanded Polystyrene-Based External Thermal Insulation Composite System. Buildings 2020, 10, 47. [Google Scholar] [CrossRef] [Scilit]
  80. Michałowski, B.; Michalak, J. Sustainability-Oriented Assessment of External Thermal Insulation Composite Systems: A Case Study from Poland. Cogent Eng. 2021, 8, 1943152. [Google Scholar] [CrossRef] [Scilit]
  81. Mohammad, M.; Masad, E.; Al-Ghamdi, S.G. 3D Concrete Printing Sustainability: A Comparative Life Cycle Assessment of Four Construction Method Scenarios. Buildings 2020, 10, 245. [Google Scholar] [CrossRef] [Scilit]
  82. Päätalo, J.; Alao, P.F.; Rohumaa, A.; Kers, J.; Liblik, J.; Lylykangas, K. Prefab Light Clay-Timber Elements for Net Zero Whole-Life Carbon Buildings. J. Sustain. Archit. Civ. Eng. 2024, 34, 89–100. [Google Scholar] [CrossRef] [Scilit]
  83. Pedroso, M.; Silvestre, J.D.; Gomes, M.G.; Bersch, J.D.; Flores-Colen, I. Application of Silica-Aerogel-Fibre-Based Thermal Renders for Retrofits in Building Walls: A Comparative Assessment with Benchmark Solutions. Gels 2023, 9, 861. [Google Scholar] [CrossRef] [Scilit]
  84. Pretot, S.; Collet, F.; Garnier, C. Life Cycle Assessment of a Hemp Concrete Wall: Impact of Thickness and Coating. Build. Environ. 2014, 72, 223–231. [Google Scholar] [CrossRef] [Scilit]
  85. Sahmenko, G.; Sinka, M.; Namsone, E.; Korjakins, A.; Bajare, D. Sustainable Wall Solutions Using Foam Concrete and Hemp Composites. Environ. Clim. Technol. 2021, 25, 917–930. [Google Scholar] [CrossRef] [Scilit]
  86. Sattler, S.; Österreicher, D. Assessment of Sustainable Construction Measures in Building Refurbishment—Life Cycle Comparison of Conventional and Multi-Active Façade Systems in a Social Housing Complex. Sustainability 2019, 11, 4487. [Google Scholar] [CrossRef] [Scilit]
  87. Scrucca, F.; Palladino, D. Integration of Energy Simulations and Life Cycle Assessment in Building Refurbishment: An Affordability Comparison of Thermal Insulation Materials through a New Sustainability Index. Sustainability 2023, 15, 1412. [Google Scholar] [CrossRef] [Scilit]
  88. Silvestre, J.; Pargana, N.; De Brito, J.; Pinheiro, M.; Durão, V. Insulation Cork Boards—Environmental Life Cycle Assessment of an Organic Construction Material. Materials 2016, 9, 394. [Google Scholar] [CrossRef] [Scilit]
  89. Sinha, A.; Kutnar, A. Carbon Footprint versus Performance of Aluminum, Plastic, and Wood Window Frames from Cradle to Gate. Buildings 2012, 2, 542–553. [Google Scholar] [CrossRef] [Scilit]
  90. Sinka, M.; Van Den Heede, P.; De Belie, N.; Bajare, D.; Sahmenko, G.; Korjakins, A. Comparative Life Cycle Assessment of Magnesium Binders as an Alternative for Hemp Concrete. Resour. Conserv. Recycl. 2018, 133, 288–299. [Google Scholar] [CrossRef] [Scilit]
  91. Struhala, K.; Čekon, M.; Slávik, R. Life Cycle Assessment of Solar Façade Concepts Based on Transparent Insulation Materials. Sustainability 2018, 10, 4212. [Google Scholar] [CrossRef] [Scilit]
  92. Tingley, D.D.; Hathway, A.; Davison, B.; Allwood, D. The Environmental Impact of Phenolic Foam Insulation Boards. Proc. Inst. Civ. Eng.-Constr. Mater. 2017, 170, 91–103. [Google Scholar] [CrossRef] [Scilit]
  93. Wadel, G.; Alonso, P.; Zamora, J.-L.; Garrido, P. Simplified LCA in Skin Design: The FB720 Case. Int. J. Sustain. Build. Technol. Urban Dev. 2013, 4, 68–81. [Google Scholar] [CrossRef] [Scilit]
  94. Zampori, L.; Dotelli, G.; Vernelli, V. Life Cycle Assessment of Hemp Cultivation and Use of Hemp-Based Thermal Insulator Materials in Buildings. Environ. Sci. Technol. 2013, 47, 7413–7420. [Google Scholar] [CrossRef] [Scilit]
  95. Park, J.H.; Yuk, H.; Kang, S.T.; Kim, S. Integrating Thermal Bridge Analysis with Life-Cycle Assessment: Energy and Environmental Performance of Ply-Lam CLT Envelopes in ZEB-Level Apartments. Build. Environ. 2026, 290, 114169. [Google Scholar] [CrossRef] [Scilit]
  96. Amoruso, F.M.; Sonn, M.-H.; Schuetze, T. Carbon-Neutral Building Renovation Potential with Passive House-Certified Components: Applications for an Exemplary Apartment Building in the Republic of Korea. Build. Environ. 2022, 215, 108986. [Google Scholar] [CrossRef] [Scilit]
  97. Gervásio, H.; Simões Da Silva, L.; Eizaguirre-Iribar, A.; Olano-Azkune, X.; Lange, J.; Pradhan, E.M.; Renaux, T.; Gelders, T.; Huet, V.; Izabel, D.; et al. Experimental Characterization of the Mechanical and Functional Performance of Innovative Ultra-Low Carbon Sandwich Panels and Envelope Systems for Buildings. Thin-Walled Struct. 2025, 210, 112999. [Google Scholar] [CrossRef] [Scilit]
  98. Rai, D.; Sodagar, B.; Fieldson, R.; Hu, X. Assessment of CO2 Emissions Reduction in a Distribution Warehouse. Energy 2011, 36, 2271–2277. [Google Scholar] [CrossRef] [Scilit]
  99. Bošković, I.; Radivojević, A. Life Cycle Assessment of Hemp-Lime Concrete Wall Constructions: The Impact of Wall Finish Type and Renewal Regimes. J. Build. Eng. 2024, 86, 108940. [Google Scholar] [CrossRef] [Scilit]
  100. Sinka, M.; Spurina, E.; Korjakins, A.; Bajare, D. Hempcrete—CO2 Neutral Wall Solutions for 3D Printing. Environ. Clim. Technol. 2022, 26, 742–753. [Google Scholar] [CrossRef] [Scilit]
  101. Pfadt-Trilling, A.R.; Fortier, M.-O.P. The Greenhouse Gas Burden of Weatherizing Northern US Homes and Estimated Lifetime Energy Savings. Cell Rep. Sustain. 2025, 2, 100550. [Google Scholar] [CrossRef] [Scilit]
  102. Pope, H.; Carver, M.; Armstrong, J. Low-Carbon Climate-Resilient Retrofit Pilot: Construction Report. Buildings 2025, 15, 3666. [Google Scholar] [CrossRef] [Scilit]
  103. Hairstans, R.; Sadiq, J.; Livingstone, A.; Stinson, J.; Saint, R. Timber Offsite MMC Living Lab: Case Study of a UK Mid-Century Bungalow Retrofit. J. Build. Eng. 2026, 119, 115131. [Google Scholar] [CrossRef] [Scilit]
  104. Hossain, M.S.; Therasme, O.; Crovella, P.; Volk, T.A. Assessing the Environmental Impact of Biobased Exterior Insulation Panel: A Focus on Carbon Uptake and Embodied Emissions. Energies 2024, 17, 3406. [Google Scholar] [CrossRef] [Scilit]
  105. Bradford, K.; Gentry, R.; Ben-Alon, L.; Kurtis, K. Construction 3D Printing Material Selection: Minimizing Cost and Carbon Footprint of Residential Wall Assemblies. Constr. Build. Mater. 2025, 493, 143150. [Google Scholar] [CrossRef] [Scilit]
  106. Globa, A.; Costin, G.; Tokede, O.; Wang, R.; Khoo, C.K.; Moloney, J. Hybrid Kinetic Facade: Fabrication and Feasibility Evaluation of Full-Scale Prototypes. Archit. Eng. Des. Manag. 2022, 18, 791–811. [Google Scholar] [CrossRef] [Scilit]
  107. Hatzfeld, T.; Schlüter, D.; Scope, C.; Krois, K.; Guenther, E.; Etzold, B.; Curbach, M. Rethinking Residential Energy Storage: GHG Minimization Potential of a Carbon Reinforced Concrete Facade with Function Integrated Supercapacitors. Build. Environ. 2022, 224, 109520. [Google Scholar] [CrossRef] [Scilit]
  108. Amoruso, F.M.; Schuetze, T. Carbon Life Cycle Assessment and Costing of Building Integrated Photovoltaic Systems for Deep Low-Carbon Renovation. Sustainability 2023, 15, 9460. [Google Scholar] [CrossRef] [Scilit]
  109. Liu, C.; Mohammadpourkarbasi, H.; Sharples, S. Life Cycle Carbon and Cost Assessments of the Retrofit to Passivhaus EnerPHit Standard of Suburban Residential Buildings in Hunan, China. Energy Build. 2025, 332, 115417. [Google Scholar] [CrossRef] [Scilit]
  110. Alabdulrazzaq, H.; Gasparri, E.; Attia, S.; Brambilla, A. Comparative Study of Conventional and Emerging Façade Systems: Pathways to Reducing Embodied Carbon and Enhancing Circularity in Buildings. Energy Build. 2026, 367, 117778. [Google Scholar] [CrossRef] [Scilit]
  111. Štompf, P.; Vaňová, R.; Jochim, S. The Environmental Impacts of Façade Renovation: A Case Study of an Office Building. Sustainability 2025, 17, 6766. [Google Scholar] [CrossRef] [Scilit]
  112. Dodoo, A.; Sathre, R.; Piccardo, C. Climate Impacts of Timber-Frame Buildings in a Life Cycle Perspective: Implications of Static and Dynamic Modelling Approaches for Biogenic Carbon Accounting. Environ. Impact Assess. Rev. 2026, 117, 108213. [Google Scholar] [CrossRef] [Scilit]
  113. Hoxha, E.; Passer, A.; Saade, M.R.M.; Trigaux, D.; Shuttleworth, A.; Pittau, F.; Allacker, K.; Habert, G. Biogenic Carbon in Buildings: A Critical Overview of LCA Methods. Build. Cities 2020, 1, 504–524. [Google Scholar] [CrossRef] [Scilit]
  114. Andersen, C.E.; Hoxha, E.; Rasmussen, F.N.; Sorensen, C.G.; Birgisdottir, H. Temporal Considerations in Life Cycle Assessments of Wooden Buildings: Implications for Design Incentives. J. Clean. Prod. 2024, 445, 141260. [Google Scholar] [CrossRef] [Scilit]
  115. Densley Tingley, D.; Hathway, A.; Davison, B. An Environmental Impact Comparison of External Wall Insulation Types. Build. Environ. 2015, 85, 182–189. [Google Scholar] [CrossRef] [Scilit]
  116. Galimshina, A.; Moustapha, M.; Hollberg, A.; Padey, P.; Lasvaux, S.; Sudret, B.; Habert, G. Bio-Based Materials as a Robust Solution for Building Renovation: A Case Study. Appl. Energy 2022, 316, 119102. [Google Scholar] [CrossRef] [Scilit]
  117. Takano, A.; Aiki, M. A Multi-Criteria Approach to Sustainable Building Material Selection: A Case Study in a Japanese Context. Sustainability 2025, 17, 4210. [Google Scholar] [CrossRef] [Scilit]
  118. Petrovic, B.; Myhren, J.A.; Zhang, X.; Wallhagen, M.; Eriksson, O. Life Cycle Assessment of a Wooden Single-Family House in Sweden. Appl. Energy 2019, 251, 113253. [Google Scholar] [CrossRef] [Scilit]
  119. Norouzi, M.; Haddad, A.N.; Jiménez, L.; Mohajerani, M.; Boer, D. Long-Term Decarbonization Prediction of Buildings Accounting for Temporal Variations in Grid and Material Emission Factors: A Case Study of Timber-Framed Passive Houses in the United Kingdom. Renew. Energy 2025, 242, 122476. [Google Scholar] [CrossRef] [Scilit]
  120. Li, X.; Densley Tingley, D. Solid Wall Insulation of the Victorian House Stock in England: A Whole Life Carbon Perspective. Build. Environ. 2021, 191, 107595. [Google Scholar] [CrossRef] [Scilit]
  121. Loli, A.; Skaar, C.; Bergsdal, H.; Reenaas, M. Comparing Embodied GHG Emissions between Environmental Product Declaration and Generic Data Models: Case of the ZEB Laboratory in Trondheim, Norway. Build. Environ. 2023, 242, 110583. [Google Scholar] [CrossRef] [Scilit]
  122. Proietti, S.; Desideri, U.; Sdringola, P.; Zepparelli, F. Carbon Footprint of a Reflective Foil and Comparison with Other Solutions for Thermal Insulation in Building Envelope. Appl. Energy 2013, 112, 843–855. [Google Scholar] [CrossRef] [Scilit]
  123. Nußholz, J.L.K.; Rasmussen, F.N.; Whalen, K.; Plepys, A. Material Reuse in Buildings: Implications of a Circular Business Model for Sustainable Value Creation. J. Clean. Prod. 2020, 245, 118546. [Google Scholar] [CrossRef] [Scilit]
  124. Backes, J.G.; Schmidt, L.; Bielak, J.; Del Rosario, P.; Traverso, M.; Claßen, M. Comparative Cradle-to-Grave Carbon Footprint of a CFRP-Grid Reinforced Concrete Façade Panel. Sustainability 2023, 15, 11548. [Google Scholar] [CrossRef] [Scilit]
  125. Moura, B.; Ramos Da Silva, T.; Soares, N.; Monteiro, H. Eco-Efficiency of Concrete Sandwich Panels with Different Insulation Core Materials. Sustainability 2025, 17, 1687. [Google Scholar] [CrossRef] [Scilit]
  126. Alam, M.; Picco, M.; Resalati, S. Comparative Holistic Assessment of Using Vacuum Insulated Panels for Energy Retrofit of Office Buildings. Build. Environ. 2022, 214, 108934. [Google Scholar] [CrossRef] [Scilit]
  127. Bucklin, O.; Di Bari, R.; Amtsberg, F.; Menges, A. Environmental Impact of a Mono-Material Timber Building Envelope with Enhanced Energy Performance. Sustainability 2022, 15, 556. [Google Scholar] [CrossRef] [Scilit]
  128. Meek, A.H.; Elchalakani, M.; Beckett, C.T.S.; Grant, T. Alternative Stabilised Rammed Earth Materials Incorporating Recycled Waste and Industrial By-Products: Life Cycle Assessment. Constr. Build. Mater. 2021, 267, 120997. [Google Scholar] [CrossRef] [Scilit]
  129. Boscato, G.; Mora, T.D.; Peron, F.; Russo, S.; Romagnoni, P. A New Concrete-Glulam Prefabricated Composite Wall System: Thermal Behavior, Life Cycle Assessment and Structural Response. J. Build. Eng. 2018, 19, 384–401. [Google Scholar] [CrossRef] [Scilit]
  130. Yılmaz, E.; Arslan, H.; Bideci, A. Environmental Performance Analysis of Insulated Composite Facade Panels Using Life Cycle Assessment (LCA). Constr. Build. Mater. 2019, 202, 806–813. [Google Scholar] [CrossRef] [Scilit]
  131. Francart, N.; Widström, T.; Malmqvist, T. Influence of Methodological Choices on Maintenance and Replacement in Building LCA. Int. J. Life Cycle Assess. 2021, 26, 2109–2126. [Google Scholar] [CrossRef] [Scilit]
  132. Echarri-Iribarren, V.; Echarri-Iribarren, F.; Rizo-Maestre, C. Ceramic Panels versus Aluminium in Buildings: Energy Consumption and Environmental Impact Assessment with a New Methodology. Appl. Energy 2019, 233–234, 959–974. [Google Scholar] [CrossRef] [Scilit]
  133. Antypa, D.; Petrakli, F.; Gkika, A.; Voigt, P.; Kahnt, A.; Böhm, R.; Suchorzewski, J.; Araújo, A.; Sousa, S.; Koumoulos, E.P. Life Cycle Assessment of Advanced Building Components towards NZEBs. Sustainability 2022, 14, 16218. [Google Scholar] [CrossRef] [Scilit]
  134. Lamnatou, C.; Smyth, M.; Chemisana, D. Building-Integrated Photovoltaic/Thermal (BIPVT): LCA of a Façade-Integrated Prototype and Issues about Human Health, Ecosystems, Resources. Sci. Total Environ. 2019, 660, 1576–1592. [Google Scholar] [CrossRef] [Scilit]
  135. ISO 14040:2006; Environmental Management—Life Cycle Assessment—Principles and Framework. International Organization for Standardization ISO: Geneva, Switzerland, 2006.
  136. ISO 14044:2006; Environmental Management—Life Cycle Assessment—Requirements and Guidelines. International Organization for Standardization ISO: Geneva, Switzerland, 2006.
  137. Ahmed Mohamed, N.; El-Dash, K.M.; Attia, T.M.; Abdel-Monem, M. Analysis of Alternative Building Envelope Solutions to Improve Energy Efficiency. Innov. Infrastruct. Solut. 2024, 9, 251. [Google Scholar] [CrossRef] [Scilit]
  138. Akkan Çavdar, A.; Vural, N. Analysis of the Embodied And Operational Energy of Wood-Based Prefabricated Panels Produced with Different Design Concepts According to Vernacular. Politek. Derg. 2024, 27, 1491–1503. [Google Scholar] [CrossRef] [Scilit]
  139. Amoruso, F.M.; Schuetze, T. Life Cycle Assessment and Costing of Carbon Neutral Hybrid-Timber Building Renovation Systems: Three Applications in the Republic of Korea. Build. Environ. 2022, 222, 109395. [Google Scholar] [CrossRef] [Scilit]
  140. Ansah, M.K.; Chen, X.; Yang, H.; Lu, L.; Lam, P.T.I. An Integrated Life Cycle Assessment of Different Façade Systems for a Typical Residential Building in Ghana. Sustain. Cities Soc. 2020, 53, 101974. [Google Scholar] [CrossRef] [Scilit]
  141. Aslani, A.; Hachem-Vermette, C. Contrasting the Environmental Impact of Conventional Walls and Magnesium Oxychloride Walls. Constr. Build. Mater. 2022, 321, 126373. [Google Scholar] [CrossRef] [Scilit]
  142. Bottino-Leone, D.; Larcher, M.; Herrera-Avellanosa, D.; Haas, F.; Troi, A. Evaluation of Natural-Based Internal Insulation Systems in Historic Buildings through a Holistic Approach. Energy 2019, 181, 521–531. [Google Scholar] [CrossRef] [Scilit]
  143. Brás, A. Embodied Carbon Minimisation of Retrofit Solutions for Walls. Proc. Inst. Civ. Eng.-Eng. Sustain. 2017, 170, 141–156. [Google Scholar] [CrossRef] [Scilit]
  144. Carabaño, R.; Pastor, R.; Bedoya, C.; Ruiz, D. Comparative Life Cycle Assessment of the Conventional Façade SOS Natura and the Natural Water Tank Façade. Constr. Build. Mater. 2016, 105, 563–571. [Google Scholar] [CrossRef] [Scilit][Green Version]
  145. Cortês, A.; Almeida, J.; Santos, M.I.; Tadeu, A.; De Brito, J.; Silva, C.M. Environmental Performance of a Cork-Based Modular Living Wall from a Life-Cycle Perspective. Build. Environ. 2021, 191, 107614. [Google Scholar] [CrossRef] [Scilit]
  146. Gómez De Cózar, J.C.; García-Martínez, A.; Morillo Merino, B.; Campón Tovar, J.A.; Rey-Álvarez, B. An Approach to Using Life Cycle Assessment Generative Algorithm in Buildings: Optimisation of BIM Models during the Early Design Phase. J. Clean. Prod. 2025, 530, 146847. [Google Scholar] [CrossRef] [Scilit]
  147. Hamida, A.; Alsudairi, A.; Alshaibani, K.; Alshamrani, O. Parametric Study of the Impact of Building Envelope Systems on Embodied and Operational Carbon of Residential Buildings. Int. J. Build. Pathol. Adapt. 2022, 40, 753–774. [Google Scholar] [CrossRef] [Scilit]
  148. Jimenez, M.S.; Cortesão, J.; Lenzholzer, S.; Walker, R. Plant Pixel: An Optimized Bio-Inspired Living Wall System. Dev. Built Environ. 2024, 18, 100438. [Google Scholar] [CrossRef] [Scilit]
  149. Kitayama, S.; Iuorio, O.; Josa, I.; Borrion, A.; Black, L. Determining the Carbon Footprint Reduction of Reusing Lightweight Exterior Infill Walls: A Case Study of a School Building in the United Kingdom. J. Clean. Prod. 2024, 469, 143061. [Google Scholar] [CrossRef] [Scilit]
  150. Kyriakidis, A.; Michael, A.; Illampas, R.; Charmpis, D.C.; Ioannou, I. Comparative Evaluation of a Novel Environmentally Responsive Modular Wall System Based on Integrated Quantitative and Qualitative Criteria. Energy 2019, 188, 115966. [Google Scholar] [CrossRef] [Scilit]
  151. Moghayedi, A.; Awuzie, B.O. A Framework for Facilitating Low-Income Net-Zero Energy Housing Delivery in Developing Countries: Insights from a Practical Case in South Africa. Build. Environ. 2025, 276, 112847. [Google Scholar] [CrossRef] [Scilit]
  152. Nawarathna, A.; Alwan, Z.; Gledson, B.; Fernando, N. Embodied Carbon in Commercial Office Buildings: Lessons Learned from Sri Lanka. J. Build. Eng. 2021, 42, 102441. [Google Scholar] [CrossRef] [Scilit]
  153. Quintana-Gallardo, A.; Romero Clausell, J.; Guillén-Guillamón, I.; Mendiguchia, F.A. Waste Valorization of Rice Straw as a Building Material in Valencia and Its Implications for Local and Global Ecosystems. J. Clean. Prod. 2021, 318, 128507. [Google Scholar] [CrossRef] [Scilit]
  154. Resalati, S.; Kendrick, C.C.; Hill, C. Embodied Energy Data Implications for Optimal Specification of Building Envelopes. Build. Res. Inf. 2020, 48, 429–445. [Google Scholar] [CrossRef] [Scilit]
  155. Roig, O.; Summa, S.; Pardal, C.; Isalgue, A.; Di Perna, C.; Stazi, F. Opaque Ventilated Façades: Energy Performance for Different Main Walls and Claddings. Energy Build. 2024, 314, 114280. [Google Scholar] [CrossRef] [Scilit]
  156. Rubio-Aguinaga, A.; Kyriakou, L.; Fernández, J.M.; Navarro-Blasco, I.; Pavia, S.; Álvarez, J.I. Sustainability of PCM-Lime Mortars for Heritage Retrofitting: Carbon Footprint and Impact on Energy Demand across Climates. Case Stud. Constr. Mater. 2025, 23, e05294. [Google Scholar] [CrossRef] [Scilit]
  157. Sáez De Guinoa, A.; Zambrana-Vasquez, D.; Alcalde, A.; Corradini, M.; Zabalza-Bribián, I. Environmental Assessment of a Nano-Technological Aerogel-Based Panel for Building Insulation. J. Clean. Prod. 2017, 161, 1404–1415. [Google Scholar] [CrossRef] [Scilit]
  158. Sameer, H.; Bringezu, S. Life Cycle Input Indicators of Material Resource Use for Enhancing Sustainability Assessment Schemes of Buildings. J. Build. Eng. 2019, 21, 230–242. [Google Scholar] [CrossRef] [Scilit]
  159. Soust-Verdaguer, B.; Llatas, C.; García-Martínez, A.; Gómez De Cózar, J.C. BIM-Based LCA Method to Analyze Envelope Alternatives of Single-Family Houses: Case Study in Uruguay. J. Archit. Eng. 2018, 24, 05018002. [Google Scholar] [CrossRef] [Scilit]
  160. Tighnavard Balasbaneh, A.; Bin Marsono, A.K.; Kasra Kermanshahi, E. Balancing of Life Cycle Carbon and Cost Appraisal on Alternative Wall and Roof Design Verification for Residential Building. Constr. Innov. 2018, 18, 274–300. [Google Scholar] [CrossRef] [Scilit]
  161. Tokede, O.; Boggavarapu, M.K.; Wamuziri, S. Assessment of Building Retrofit Scenarios Using Embodied Energy and Life Cycle Impact Assessment. Built Environ. Proj. Asset Manag. 2023, 13, 666–681. [Google Scholar] [CrossRef] [Scilit]
  162. Velasco Vega, D.S.; Shepherd, K.M.; Guthrie, W.S.; Bingham, E.; South, A. Passive Thermal Performance of Thin-Shell Concrete Dome Structures and Comparable Code-Compliant Wooden-Frame Structures. Energy Build. 2024, 324, 114835. [Google Scholar] [CrossRef] [Scilit]
  163. Victoria, M.F.; Deveci, G.; Musau, F.; Clubb, M. Life Cycle Carbon and Cost Assessment Comparing Milled and Whole Timber Truss Systems and Insulation Options for Affordable Housing. Energy Build. 2023, 285, 112895. [Google Scholar] [CrossRef] [Scilit]
  164. Yılmaz, E.; Aykanat, B.; Çomak, B. Environmental Life Cycle Assessment of Rockwool Filled Aluminum Sandwich Facade Panels in Turkey. J. Build. Eng. 2022, 50, 104234. [Google Scholar] [CrossRef] [Scilit]
  165. Yu, D.; Tan, H.; Ruan, Y. A Future Bamboo-Structure Residential Building Prototype in China: Life Cycle Assessment of Energy Use and Carbon Emission. Energy Build. 2011, 43, 2638–2646. [Google Scholar] [CrossRef] [Scilit]
  166. Zaborova, D.; Musorina, T. Environmental and Energy-Efficiency Considerations for Selecting Building Envelopes. Sustainability 2022, 14, 5914. [Google Scholar] [CrossRef] [Scilit]
  167. Zeng, R.; Chini, A.; Ries, R. Innovative Design for Sustainability: Integrating Embodied Impacts and Costs during the Early Design Phase. Eng. Constr. Archit. Manag. 2020, 28, 747–764. [Google Scholar] [CrossRef] [Scilit]
  168. Zhu, P.; Tao, T.; Chen, H.; Chen, C.; Jiang, F.; Liu, H.; Yan, X.; Yang, L. Low-Carbon Fire-Resistant Masonry Mortar Incorporating Decoration Waste Recycled Aggregates for Sustainable Building Envelopes. Constr. Build. Mater. 2026, 507, 145065. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.