Skip to Content
BuildingsBuildings
  • Article
  • Open Access

24 September 2026

28 Pages

A BIM-Based AI Agent for Early-Stage Seismic Eccentricity Assessment and Design Decision Support: EccenAI

,
and
1
Department of Informatics, Graduate School, Istanbul Technical University, Taşkışla Campus, Sisli, 34367 Istanbul, Türkiye
2
Department of Architecture, Faculty of Architecture and Design, Van Yüzüncü Yıl University, Zeve Campus, Tusba, 65090 Van, Türkiye
3
Department of Architecture, Faculty of Architecture, Istanbul Technical University, Taşkışla Campus, Sisli, 34367 Istanbul, Türkiye
*
Author to whom correspondence should be addressed.

Abstract

Architectural decisions made during the early design stage can substantially influence the mass–stiffness distribution of a building, yet eccentricity-related seismic performance is typically assessed only after major design decisions have been established. This study presents EccenAI, a Building Information Modeling (BIM)-based artificial intelligence (AI) agent developed as an Autodesk Revit plug-in to support early-stage eccentricity assessment and design decision-making. The framework integrates deterministic rule-based calculations with large language model (LLM)-assisted interpretation and design guidance. Geometric, physical, and structural data are extracted through the Revit API to calculate the center of mass (CM), center of rigidity (CR), and normalized eccentricity. The framework was evaluated as a proof-of-concept using square, rectangular, and L-shaped floor-plan configurations. The square plan yielded eccentricity ratios of 1.93% and 0.61% in the x- and y-directions, respectively. Following AI-assisted design revisions, the rectangular plan reduced its critical x-direction eccentricity from 23.32% to 9.70%, while the L-shaped plan reduced its critical y-direction eccentricity from 23.07% to 15.80%. The results demonstrate the feasibility of integrating deterministic BIM-based assessment with LLM-assisted reasoning and validated model modifications as an early-stage decision-support approach rather than a substitute for detailed structural analysis.

1. Introduction

In the early stages of architectural design, the layout of the plan contains critical parameters that form the basis for structural decisions [1,2]. In countries located in active earthquake zones, such as Türkiye, these considerations become particularly important because architectural design decisions made at this stage may affect the distribution of mass and stiffness within the building [3,4]. Compliance with seismic requirements in Türkiye is assessed in accordance with the Turkish Building Seismic Code (TBDY 2018) [5]. However, many code-related structural criteria are typically evaluated only after major architectural decisions have already been established, which can lead to costly revisions and additional coordination between architectural and structural engineering disciplines [6,7]. This creates a need for computational decision-support approaches that can make structurally relevant information available earlier in the design process [8,9].
Among the criteria defined by TBDY 2018 [5], eccentricity is directly related to the spatial relationship between the center of mass (CM) and the center of rigidity (CR). The code limits eccentricity according to the criterion (e ≤ L/5), where e represents the distance between CM and CR, and L denotes the relevant plan dimension. Although this criterion relates directly to architectural plan organization and mass distribution, it is generally assessed during later structural analysis stages. Deferring its evaluation can therefore increase the likelihood of subsequent design revisions and coordination demands [3,4]. BIM models already contain much of the geometric, physical, and semantic information required for such an assessment, yet conventional BIM workflows do not automatically translate these data into interpretable structural feedback during conceptual design. Previous algorithm-aided BIM studies have nevertheless demonstrated the potential of integrating quantitative analysis and computational methods into early-stage design workflows [9].
BIM environments provide a data-driven infrastructure that integrates interdisciplinary data and incorporates analytical processes into the design process [10,11]. In this context, Automated Code Compliance (ACC) systems have been developed to verify building models against regulatory requirements [6,12,13]. While these systems can verify regulatory provisions on a rule-based basis, they remain limited in their ability to interpret these provisions or translate them into design revisions [14,15]. Early implementations such as CORENET [16], DAuto [17], and BIM-based fire egress checking systems [6] demonstrate the effectiveness of rule-based automation for predefined compliance tasks. More recent studies have incorporated deep learning, natural language processing (NLP), and large language models (LLMs) into BIM-based compliance workflows for applications including structural irregularity detection, fire safety, and accessibility assessment [12,18,19,20]. Despite these advances, most ACC systems remain primarily oriented toward identifying whether an existing design satisfies predefined requirements rather than explaining the implications of non-compliance or supporting design revision.
The emergence of LLM-based AI agents has expanded this scope from rule verification toward interactive BIM assistance, model authoring, and decision support. Additionally, agentic frameworks extend these capabilities to construction through LLM-based digital twin updates [21]. DAVE [10] and the multi-agent framework proposed by Guo et al. [22] enable natural-language interaction with BIM data and Revit functions. RevitCopilot [15] extends this interaction by detecting design issues and implementing corrective actions through the Revit API, while AI BIM Coordinator [23] supports model coordination tasks such as element creation, clash detection, and view management. Text2BIM [24] generates editable BIM models from natural-language instructions, NADIA [25] supports architectural detailing based on design and engineering constraints, Archi-Agents [26] introduces specialized professional agents, and BIMgent [27] explores autonomous BIM authoring through GUI-based interaction. Collectively, these studies demonstrate the growing capability of LLM-based agents to support BIM interaction, modeling, and design automation. However, their primary focus remains on model generation, coordination, and task execution rather than engineering-driven performance assessment [28].
A smaller body of research has addressed structural performance and engineering-oriented design support. İdemen [3] demonstrated an early expert-system approach that translated CM–CR assessment into design feedback within a CAD environment. Subsequent studies explored the detection of structural irregularities from architectural floor plans using computer vision [7], while Jadhav and Barati Farimani [29] integrated an LLM-based agent with finite element analysis workflows to evaluate structural alternatives and generate performance-based recommendations. These studies indicate the potential of AI-assisted systems to support engineering-informed design decisions; however, BIM-integrated approaches that combine code-based structural assessment with LLM-assisted interpretation during early architectural design remain limited.
Table 1 presents the existing BIM-based LLM agent systems. “✓” indicates that the feature is supported, “-” indicates partial support, and “X” indicates that the feature is not supported. Based on these studies, it can be observed that AI-agent systems capable of structural performance assessment remain limited. Similarly, relatively few studies integrate rule-based or code-based evaluation, indicating that hybrid approaches combining these capabilities are even less common.
Table 1. Comparison of BIM-integrated LLM-based agent systems.
The resulting research gap concerns not the individual availability of BIM, LLMs, or rule-based compliance checking, but their coordinated use for early-stage structural decision support. Architects require more than a binary compliance result: they also need to understand why a design performs unfavorably and which modifications may improve it while major spatial decisions are still flexible. Previous BIM-based decision-support studies have shown the potential of computational optimization for generating and comparing design alternatives [9,30], yet the integration of deterministic seismic assessment with LLM-assisted interpretation and BIM-level design modification remains underexplored.
To address this gap, this study proposes EccenAI, a BIM-based AI agent that combines deterministic rule-based structural assessment with LLM-assisted design guidance. The framework evaluates plan-level eccentricity using geometric and structural information extracted through the Revit API in accordance with TBDY 2018 [5], with the current implementation focusing on reinforced-concrete structural systems. It is intended to support early-stage architectural decision-making through quantitative eccentricity assessment, interpretable feedback, and validated design recommendations rather than to replace detailed structural or seismic analysis. The study is conducted as a proof-of-concept to investigate whether a BIM-integrated hybrid framework combining deterministic eccentricity assessment with LLM-assisted reasoning can provide actionable design support during the early architectural design stage.
Accordingly, the study makes three contributions. First, it introduces a BIM-based framework for evaluating the eccentricity criterion defined in TBDY 2018 [5] during early design, enabling selected structural performance considerations to enter architectural decision-making before detailed engineering analysis. Second, it proposes a hybrid AI-agent architecture that separates deterministic engineering calculations from LLM-based interpretation, allowing quantitative assessment results to be transformed into explainable design feedback while preserving the traceability of the underlying calculations. Third, it evaluates the framework across different floor-plan typologies and examines its capacity to generate and validate design revision recommendations within the BIM environment.

2. Materials and Methods

This study adopts an action research approach based on iterative development, testing, and evaluation. This approach was selected because the research required the computational framework to be developed and evaluated through successive cycles in which implementation findings directly informed subsequent system revisions. Within this framework, EccenAI was developed as a Autodesk Revit (Autodesk, Inc., San Francisco, CA, USA) based AI agent for plan-level eccentricity assessment and design support during the early design stage. The prototype was progressively refined through cycles of implementation, error identification, and re-evaluation.
The study was structured as a proof-of-concept to assess the feasibility of integrating BIM-based deterministic structural assessment with LLM-assisted design guidance. Accordingly, the framework was evaluated using controlled BIM-based floor-plan configurations rather than a full-scale real-world building project. These configurations were selected to represent different spatial and structural conditions, enabling the effects of plan geometry, core location, and structural element distribution on eccentricity assessment and design recommendations to be examined systematically.
The research process began with a literature review and practical examination to identify a research gap. Accordingly, a hybrid framework was developed to combine deterministic eccentricity assessment with LLM-assisted interpretation and design recommendation. Figure 1 summarizes the iterative research workflow, covering problem definition, framework design, system implementation, case study evaluation, result analysis, and validation, with iterative refinement based on identified issues.
Figure 1. Research workflow (authors).
The framework was implemented as a Revit plugin using the Revit API (Autodesk, Inc., San Francisco, CA, USA). Geometric and structural data extracted from the BIM model were processed by the deterministic assessment module to evaluate the CM–CR relationship in accordance with TBDY 2018 [5], while the LLM component interpreted the resulting performance indicators and generated design-oriented recommendations.
Initial testing focused on identifying computational errors, BIM-modeling limitations, and inconsistencies in LLM-generated outputs. These observations informed subsequent refinements to the data-extraction procedure, calculation workflow, and agent-routing strategy. The revised implementation was then re-evaluated using the same controlled configurations to assess whether the identified issues had been resolved and whether the generated recommendations had become more consistent and relevant.
For the final proof-of-concept evaluation, three floor-plan typologies were considered: square, rectangular, and L-shaped configurations. These typologies were selected to represent different degrees of plan regularity and geometric asymmetry. The evaluation examined how plan typology, core location, and structural element distribution influenced eccentricity assessment and the resulting design recommendations. A five-level scoring scheme was used as a comparative decision-support metric, while the subsequent sections detail the data-extraction process, deterministic calculations, LLM-assisted recommendation mechanism, and evaluation criteria.

2.1. Proposed Framework

As part of this study, a BIM-based AI-agent framework was developed to assess eccentricity during the early design phase and to propose design revisions. The system consists of four main components: BIM data extraction, rule-based assessment, and LLM-based AI analysis and optimization (Figure 2).
Figure 2. System workflow (authors).
The framework development process is structured around five core tasks: identifying architectural and structural elements, calculating CM and CR, assessing eccentricity, verifying compliance with regulatory requirements, and generating design proposals where necessary.
To support systematic and traceable design decisions, the Design Rationale approach was adopted [31]. The QOC (Questions, Options, Criteria) notation proposed by Maclean et al. [32] was used to structure the basic design decisions (Table 2). The design decisions were organized into five categories: Data Processing, Structural Analysis, AI-Based Decision Support, Optimization, and User Interaction. These categories cover BIM data extraction and element classification, CM–CR and eccentricity calculations, LLM-based interpretation and recommendation generation, optimization strategy, and user interaction through the WPF-based interface.
Table 2. Design decisions and their rationales based on the QOC framework.

2.2. System Architecture

The proposed system, named EccenAI, was developed as a Revit plugin. The plugin comprises three primary user-facing modules: Eccentricity Check, AI Analysis Report, and Auto Optimize. These modules are supported by a backend architecture consisting of BIM data extraction, rule-based eccentricity assessment engine, and LLM-based analysis and an AI agent.

2.2.1. Data Extraction

The proposed framework utilizes the Autodesk Revit API to directly extract the geometric, physical, and semantic information required for eccentricity assessment. Based on the floor level and building use type selected by the user, relevant BIM elements, including floor slabs, structural columns, walls, beams, stairs, and stair landings, are automatically identified and processed. For each structural element, attributes such as location, dimensions, area, and centroid coordinates are automatically retrieved.
The extracted information is used to determine the center of mass (CM) and the center of rigidity (CR). CM is calculated from the seismic mass contributions of floor slabs, structural elements, beams, stairs, modeled or equivalent partition-wall loads, and the code-defined portion of live loads. Element masses are derived from BIM geometry and material properties; when material density is unavailable, a default reinforced-concrete unit weight of 25 kN/m3 is assumed [33,34]. CR is determined from the relative lateral stiffness of structural columns and reinforced-concrete shear walls, considering their dimensions, orientations, story heights, and effective section stiffness modifiers. In addition, basic dimensional requirements for structural elements are evaluated through rule-based constraints defined for the conceptual design stage. These constraints include minimum and maximum dimensions and limits of columns, shear walls, etc. Beams are included in the CM calculation but excluded from the simplified CR model. The extracted data are also used to calculate floor dimensions (Lx and Ly) and other code-compliance parameters, which constitute the primary inputs for the rule-based assessment module and LLM-based AI agent. The data extraction and calculation process is performed automatically in the background without requiring direct user interaction.
Floor openings and shafts are treated as geometric voids. Partition-wall loads are handled either through explicitly modeled walls or, when such walls are not present, through an equivalent distributed load to avoid double counting. The current implementation focuses on reinforced-concrete structural systems and provides a simplified floor-level assessment. Common assumptions regarding material properties and effective stiffness are adopted for the relative stiffness and mass calculations (Table 3). The approach does not perform detailed finite-element, dynamic, or three-dimensional structural analysis; rather, it is intended as an early-stage BIM-based assessment of the relationship between CM and CR and the resulting eccentricity.
Table 3. Parameters and calculation methods used for seismic mass and stiffness estimation.

2.2.2. Rule-Based Assessment

According to Clause 17.2.8 of TBDY 2018 [5], “Except for the partial basement, on all floors, the eccentricity between the building’s center of mass and center of rigidity—calculated according to Section 17.5.1—for each seismic direction shall not exceed 1/5 of the floor plan length in the direction perpendicular to the relevant seismic direction. When reinforced concrete walls are used in the structural system, the building plan must include a total of at least two rectangular walls or wall sections in each direction, with at least one on each side of the floor center of mass.” This eccentricity criterion has been established. This criterion is mathematically expressed as “e ≤ L/5”; “e” represents eccentricity, and “L” represents the plan length.
Although the eccentricity calculation is verified on the floor plan, it applies to each floor along the x- and y-axes. In this study, eccentricity (e) is defined as the plan-level distance between CM and CR [37,38]. According to TBDY 2018 [5], CM is the theoretical point where the dead loads of a floor and a specific portion of the live loads are concentrated, and it is assumed that the inertial forces under seismic action act through this point. The floor mass is calculated based on the total weight (W) and consists of dead-load (G) and live-load (Q) components. Dead loads include all permanent elements, such as floors, columns, beams, shear walls, and cladding. The weight of non-structural elements is included in the system if it exceeds 10% of the total floor weight; however, doors, windows, and facade elements were not considered throughout this work.
Not all live loads are considered; only the portion multiplied by the mass participation factor (n)—which is defined based on the building’s intended use—is taken into account (n = 0.30 for residential buildings, etc.; n = 0.60 for educational and assembly buildings; n = 0.80 for warehouses). Although 30% of snow loads may be considered for the roof level, this has been omitted in this study, which focuses on the early design phase. In industrial buildings, n = 1 is used for fixed equipment, while crane loads are not included in the floor mass. Special cases are not evaluated within the scope of the proposed plugin. The mass calculation formula is:
m j = w G j + n · w Q j g .
Here, wGj represents the dead load acting at node j, wQj represents the live load acting at node j, n is the live-load mass participation factor, and g is the gravitational acceleration.
Several building components and loads were excluded from the mass and eccentricity calculations to maintain a consistent early-stage assessment framework. Doors, windows, façade elements, and shaft openings were not explicitly included because their detailed representation and loading information may not be consistently available at the conceptual design stage. Snow loads were also excluded because the study focuses on typical floor configurations rather than roof-level assessment. Non-structural elements were considered only when represented in the BIM model and included according to the defined mass-assumption rules. These exclusions may affect the estimated floor mass distribution and, consequently, the calculated CM and eccentricity, particularly in cases where non-structural or façade loads are spatially non-uniform. Therefore, the results should be interpreted as an early-stage screening of plan-level eccentricity rather than a comprehensive structural seismic assessment.
The CM of the layer is calculated using the node masses obtained via the weighted average method based on the coordinates of the masses. Accordingly, the position of CM is determined by taking into account the mass and position of each node. This approach is based on the principle of CM as defined in classical mechanics [39]. The formula for the coordinates for x and y is:
C M x = Σ m j ⋅   x j Σ m j , C M y = Σ m j ⋅   y j Σ m j .
Here, xj and yj denote the coordinates of each element. According to TBDY 2018 [5], CR is the weighted CR of the structural members (walls, columns, etc.) that resist horizontal forces acting on the building. From the perspective of seismic analysis and structural design, the importance of this point lies in its role in determining the building’s torsional behavior. For shear walls, the directional stiffness contribution is determined according to the wall orientation and cross-sectional geometry, consistent with the directional stiffness approach defined in TBDY 2018 [5], calculated as follows:
k x = b w l w 3 / h i , k x = l w b w 3 / h i , k y = l w b w 3 / h i , k y = b w l w 3 / h i .
In these formulas, “bw” represents the short side of the wall, while “lw” represents the long side. “hi” denotes the story height. For shear walls that are not aligned with the global x- or y-axis, the strong- and weak-direction stiffness contributions are transformed into the global coordinate system according to the wall orientation.
CR is determined from the relative stiffness contributions of the lateral-load-resisting structural members at each floor. The stiffness calculation includes structural columns and reinforced concrete shear walls, while beams, slabs, partition walls, stairs, and openings are excluded from the CR calculation. For the deterministic stiffness assessment, structural members are represented using the member-level lateral stiffness formulation, presented in Equation (4) [40].
k = 12 E I   /   h 3 .
This formulation is based on the fundamental principles of structural mechanics and relates the lateral stiffness of a structural member to its material and geometric properties. In the proposed implementation, the resulting stiffness values are used as relative stiffness contributions in the normalized CR calculation rather than as absolute structural stiffness values. Therefore, common parameters shared by the structural members on the same floor, including the modulus of elasticity and story height, do not affect the normalized CR coordinates.
Effective section stiffness reduction factors of 0.70 for reinforced concrete columns and 0.50 for shear walls are applied to account for the reduced stiffness of reinforced concrete members under seismic loading [5]. These factors modify the relative stiffness contributions used in the CR calculation.
According to TBDY 2018 [5], the resulting directional stiffness values are then used to calculate the center of rigidity as a stiffness-weighted average of the member locations, expressed as follows:
C R x = Σ k y i ⋅   x i Σ k y i , C R y = Σ k x i ⋅   y i Σ k x i .
In this context, the CR coordinates are determined by considering the stiffness of each element and its position in the plan view. The resulting CR is evaluated together with the CM to analyze the building’s eccentricity. Accordingly, the effective stiffness of each member is calculated by multiplying its gross-section stiffness by the corresponding reduction factor. These factors provide a more realistic representation by reducing the members’ stiffness. As required by the code, the factors are incorporated into the calculation model and applied separately to bending and shear stiffness. Additionally, these factors are only used in analyses performed under seismic load combinations. Based on these calculations and formulas, the distance between the CM and CR coordinates represents the eccentricity as expressed:
e   =   C M   −   C R .
Table 4 summarizes the BIM data extracted for the calculation of the CM and CR, together with the parameters derived from each structural element. In addition to calculating system eccentricity, the framework verifies compliance with the relevant provisions of TBDY 2018 [5], including accidental eccentricity requirements and shear-wall criteria.
Table 4. Parameters used in CM and CR calculations.
Accidental Eccentricity: According to TBDY 2018 [5], this is a parameter defined to account for uncertainties in the effect of seismic ground motion on a building, as well as potential variations in the structural system’s stiffness and mass distribution; it is generally taken as ±5% of the floor dimension perpendicular to the assumed seismic direction. Clause 4.5.10.1 of TBDY 2018 states, “An additional eccentricity effect is defined to account for potential uncertainties in the building’s response to seismic ground motion and in the stiffness and mass distribution of the structural system.” It is defined as “e = 0.05∙L.”
Shear Wall Rule: TBDY 2018 [5], in Clause 17.2.8, states, “When reinforced concrete shear walls are used in the structural system, the building plan must include a total of at least two rectangular shear walls or shear wall sections in each direction, with at least one on each side of the floor’s center of mass.” This section defines the criteria for shear walls. In line with this, this criterion is also verified in this study.
Table 5 presents the pseudocode of the rule-based assessment module, outlining its main processing steps from BIM data extraction to eccentricity and compliance assessment.
Table 5. Rule-based assessment pseudocode.

2.2.3. LLM-Based Analysis and AI Agent

The proposed AI agent operates as a design support component within a BIM environment. The function of this agent is different from that of traditional ACC systems, which only report compliance results. This agent is able to interpret the evaluation outputs and generate design revision recommendations. The aim of these recommendations is to reduce the eccentricity-based risk of torsion.
During the development of the framework, Gemini 2.5 Flash was initially employed as the LLM component due to its favorable balance between reasoning capability, response speed, and operational cost [41]. As the system evolved, the LLM component was updated to Gemini 3.5 Flash to leverage its improved reasoning, instruction-following, and agentic task performance [42]. The final implementation uses Gemini 3.5 Flash with a temperature of 0.0 and a maximum output length of 2048 tokens, with Gemini 2.5 Flash retained as a fallback if the primary model fails or returns an empty response. Since the LLM interprets structured assessment results rather than performing engineering calculations, the deterministic calculation engine remains independent of the LLM.
The agent receives structured outputs from the rule-based assessment module rather than directly interpreting raw BIM geometry. These inputs include CM and CR coordinates, eccentricity values and ratios, plan dimensions, structural wall distribution, floor span ratios, and compliance status. Based on the identified deficiencies, the agent generates 3–5 candidate modifications in a structured JSON format. Permitted operations include resizing or relocating existing walls and columns and adding new structural elements.
Candidate modifications are prioritized using a predefined P1–P7 strategy that favors solutions requiring minimal architectural intervention (Table 6). Modifications to existing elements are prioritized over adding new elements or making more substantial structural changes. However, priority alone does not determine the final recommendation; technically feasible candidates are further evaluated according to their expected effects on eccentricity, rule compliance, and the extent of architectural and structural intervention.
Table 6. P1–P7 optimization strategy.
LLM-generated candidates are not directly applied to the BIM model. Each candidate is first subjected to deterministic geometric and structural checks, including floor boundaries, openings and shafts, element conflicts, dimensional constraints, load-path continuity, and plan asymmetry. Valid candidates are then temporarily applied through a Revit transaction, and CM, CR, eccentricity, and relevant rule results are recalculated. The transaction is subsequently rolled back, allowing the candidates to be evaluated without modifying the original model. Candidates that improve eccentricity or the relevant shear-wall distribution rule are considered effective and are ranked according to their performance improvement, compliance, intervention level, plan suitability, and P1–P7 priority. The highest-ranked valid candidate is presented to the user, and permanent modification is performed only after explicit user approval. Following approval, the model is updated and the structural indicators are recalculated.
A temperature of 0.0 was used to reduce variability in LLM-generated recommendations; however, repeated-run consistency was not systematically evaluated in this proof-of-concept study. Therefore, LLM outputs are treated as decision-support inputs rather than deterministic engineering decisions. The use of structured inputs, constrained JSON outputs, and deterministic validation and dry-run procedures helps limit the effect of output variability on the final recommendation process.
Consequently, the proposed framework features a hybrid architecture. While deterministic engineering calculations are performed using rule-based algorithms, design revision recommendations are generated through LLM-based reasoning. This approach transforms traditional compliance-checking systems from passive verification tools into active design support systems capable of assisting architects in the early stages of the design process.

2.3. EccenAI Workflow

The proposed EccenAI workflow is designed to support early-stage seismic eccentricity assessment and design decision-making. Figure 3 illustrates the workflow of the proposed framework. The system first extracts data from the user-selected floor plan. Based on the extracted data, CM and CR are calculated using the rule-based assessment module. Subsequently, the eccentricity ratios (e/L) are calculated in both the x- and y-directions. According to TBDY 2018 [5], the eccentricity ratio should not exceed 20%. In addition to this code requirement, the proposed system classifies the calculated eccentricity values into five performance categories, including values below and above the code limit.
Figure 3. EccenAI workflow (authors).
Table 7 presents the pseudocode of the EccenAI workflow, outlining the main steps of the proposed AI agent from BIM data extraction and eccentricity assessment to AI-assisted design recommendations and optimization.
Table 7. EccenAI pseudocode.
To evaluate structural behavior in the plan view, the e/L ratio, defined by the distance between CM and CR, was classified on a five-level scale. Higher e/L values indicate a greater separation between the centers and, consequently, a potentially less balanced mass–stiffness distribution. Accordingly, Score 1 represents the most balanced condition, whereas Score 5 represents the least balanced condition (Table 8). The 20% threshold corresponds to the maximum eccentricity criterion specified in TBDY 2018 [5], while the intermediate and upper classification ranges (5%, 10%, and 30%) were defined in this study as heuristic thresholds to distinguish design alternatives below and above the code limit. The classification also makes the degree of plan balance visible to the user. These thresholds are not prescribed limit values in TBDY 2018 [5] and are used only for the comparative evaluation and ranking of design scenarios. The classification enables the system to distinguish different levels of eccentricity and supports the generation and comparison of design recommendations.
Table 8. The proposed classification.
Based on the classification, the AI analysis module generates explanatory design feedback. Proposed modifications are reviewed and approved by the user before being applied to the BIM model, after which the eccentricity values are recalculated.

2.4. System Implementation

Geometric and spatial data pertaining to architectural and structural elements in the model are retrieved via the Revit API and fed into the calculation process. In this context, the eccentricity calculation is performed based on predefined rules. Beyond deterministic assessment, the LLM-assisted agent interprets the calculated results, generates candidate design revisions, and, following validation and user approval, applies selected modifications to the BIM model.
Autodesk Revit 2026 was selected as the BIM platform because of its BIM-based environment and support for interdisciplinary workflows. The plugin was developed using the Revit API with C#. A dockable panel and Ribbon panel were implemented to provide the user interface, as shown in Figure 4. The Revit C# API was implemented using the Google Antigravity IDE (Google LLC, Mountain View, CA, USA).
Figure 4. EccenAI plugin architecture (authors).
The proposed plugin’s main features include analysis tools and guidance tools. It operates on both rule-based and LLM-based principles. The proposed plugin consists of three main tools (Figure 4):
  • Eccentricity Check: The module visualizes the calculated eccentricity ratios (e/L) on a performance bar. The corresponding performance category, determined according to the proposed classification scheme, is also presented. Furthermore, the interface displays the results of the additional code compliance checks, providing users with a comprehensive overview of the structural assessment. This part is the rule-based calculation module.
  • AI Analysis Report: The module generates explanatory feedback on design performance by interpreting rule-based evaluation results using an LLM. By analyzing parameters such as eccentricity values, structural distribution, floor-plan geometry, and code violations, this module identifies potential causes of torsional risk. Unlike traditional compliance-checking systems, it does not merely provide information on violations but also generates recommendations for improving the design. This section is the AI analysis module.
  • Auto Optimize: The module supports the generation of alternative design scenarios based on the recommendations produced by the AI Analysis Report. During this process, design parameters such as wall layouts, column positions, and floor-plan organization are modified to generate new design alternatives. Once the proposed recommendations are approved by the user, they are applied to the model. The system continues generating recommendations until the user terminates the process or no further valid improvement is identified under the defined criteria.
The generated alternatives are subsequently re-evaluated, and their eccentricity performance is compared. In this way, the system evolves from a conventional code-compliance-checking tool into an iterative decision-support mechanism that guides architectural design decisions. Within this module, modifications to the core location are restricted in accordance with architectural and structural constraints, while the priorities for design revisions are defined through the prompting strategy. The prioritization process considers the severity of code violations, their impact on eccentricity, and the feasibility of the proposed solution. Consequently, rather than assigning equal importance to all recommendations, the system prioritizes interventions that are expected to reduce eccentricity and improve plan-level mass–stiffness balance. This section is the AI-agent module.
Apart from the main tools, the level selection tool among the analysis tools is the one where the user must select the level. Among the guidance tools, the shear-wall and additional eccentricity tools contain and explain the additional rules stipulated in the regulation when defining the eccentricity rule (Figure 5).
Figure 5. EccenAI plugin (plugin ribbon bar view).

3. Case Study

As a proof-of-concept evaluation, three different floor-plan typologies were tested to examine the feasibility and behavior of the proposed framework under controlled design scenarios.

3.1. Square Floor Plan

The first floor plan evaluated in the case study is a square-shaped plan and is shown in Figure 6. The plan measures 15 m × 15 m and is based on a residential use scenario. The structural grid consists of 7.5 m spans in both directions, providing a regular and symmetrical layout. The floor-to-floor height is 3.6 m. Reinforced concrete columns are modeled with cross-sectional dimensions of 600 mm × 750 mm, while the beams have dimensions of 160 mm × 320 mm. The shear walls are designed with a uniform thickness of 300 mm and are symmetrically distributed around the centrally located core. This configuration was intentionally selected to represent a structurally balanced floor plan where the expected torsional irregularity is minimized.
Figure 6. Square floor plan: (a) Eccentricity Check module; (b) AI Analysis Report module; (c) Auto Optimize module.
According to the analysis results, as shown in Figure 6a, the plan achieved a Score 1—Optimal result. The eccentricity ratio was calculated as 1.93% in the x-direction and 0.61% in the y-direction. Additionally, the plan satisfied the criteria defined by both the additional eccentricity check and the shear-wall rules.
Although the current eccentricity values fall within the acceptable range, the AI Analysis Report module presented in Figure 6b provides a more detailed evaluation of the floor plan and generates additional design recommendations. The analysis identified an asymmetrical distribution of lateral force-resisting walls and a stiffness-to-mass eccentricity caused by the unbalanced placement of shear walls relative to the reinforced concrete framing system. According to the report, this condition may induce torsional behavior under lateral seismic loading and result in non-uniform displacement across the floor diaphragm. To address these issues, the module recommends shifting the shear walls southward and eastward to achieve a more balanced stiffness distribution and optimizing the location of the structural core to improve the alignment between CM and CR. The report further suggests that a more symmetrical wall layout could significantly improve the torsional stability of the structural system. Core relocation may be identified as a potential design strategy in the report; however, it is not included among the executable modification operations of the current prototype.
The square-plan case also illustrates the distinction between qualitative LLM interpretation and deterministic decision logic: although the LLM identified potential opportunities for greater symmetry, the rule-based assessment classified the configuration as acceptable and prevented unnecessary model modification.
Finally, Figure 6c shows the Auto Optimize module. Since the system is in the optimal class as a result of the evaluation, the agent does not suggest any changes to the plan. In this module, the agent supports an iterative optimization process to improve the performance of the current plan. This result demonstrates that the developed rule-based evaluation and optimization approach intervenes only in problematic cases, while preserving the existing solution in designs that meet performance criteria.

3.2. Rectangular Floor Plan

The second case study evaluates a rectangular floor plan measuring 15 m × 25 m, representing an office building scenario, as shown in Figure 7. Although the structural system was designed to be symmetrical, the core element is positioned closer to the left-hand side of the plan. The floor-to-floor height is set at 3.6 m and the reinforced concrete columns have cross-sectional dimensions of 600 mm × 750 mm. The structural grid consists of spans of 13.9 m and 11.1 m in the longitudinal direction. Additionally, the structural system incorporates shear walls with a uniform thickness of 300 mm. Despite the structure’s relatively regular layout, the asymmetric positioning of the core is expected to affect the building’s mass-stiffness relationship.
Figure 7. Rectangular floor plan: (a) Eccentricity Check module; (b) AI Analysis Report module; (c) revision suggestion of the Auto Optimize module; (d) stop–continue screen; (e) result of the Auto Optimize module; (f) final floor plan.
The analysis results showed that the eccentricity ratio was 23.32% in the x-direction and 1.74% in the y-direction. Based on these values, the plan was classified as Score 4—Poor, as shown in Figure 7a. Upon reviewing the results, it can be seen that the eccentricity ratio in the x-direction exceeds the 20% limit specified by the code. Furthermore, the X + 5% value calculated in the supplementary eccentricity check was 28.32%, which also exceeds the acceptable threshold. In the shear wall rule evaluation, the plan failed to satisfy the defined y-direction criteria.
These results indicate that positioning the core away from the center within the plan increases the distance between CM and CR and creates a significant torsional irregularity, particularly along the x-direction. Furthermore, the insufficiently balanced distribution of shear walls along the y-axis has been assessed as a risk factor that could cause the structure to exhibit irregular behavior under seismic loads.
The AI Analysis Report, shown in Figure 7b, revealed significant spatial asymmetry in the lateral load-resisting system. The structural walls and other vertical load-bearing elements are concentrated on the western side of the floor plan, resulting in limited lateral resistance along the eastern perimeter. The analysis also revealed a substantial misalignment between CM and CR, exacerbated by the concentration of office loads in certain areas. According to the assessment, this configuration may result in severe torsional behavior under seismic loading. Consequently, excessive displacement demands may develop along the more flexible eastern side, while shear forces are likely to concentrate within the stiffer western shear walls and structural core. To mitigate these issues, the report recommends introducing additional shear walls or braced frames along the eastern perimeter, as well as adjusting the core location, to achieve a more balanced distribution of mass and stiffness. It further indicates that these interventions could significantly reduce torsional sensitivity and improve the building’s overall seismic performance.
Finally, the Auto Optimize module, shown in Figure 7c, provided a recommendation for improving the current design. The system suggested converting a section of the exterior walls into shear walls to achieve a more balanced distribution of stiffness. As a result of implementing the proposed intervention, improvements were achieved in eccentricity values, and the plan’s performance score rose from Score 4—Poor to Score 2—Good, as shown in Figure 7d. Figure 7e shows the results following the changes made, and Figure 7f shows the updated version of the plan. These findings demonstrate the feasibility of using the AI-agent-based optimization approach to improve eccentricity performance under the tested design scenario.

3.3. L-Shaped Floor Plan

The third case study examines the performance of an asymmetric L-shaped floor plan to evaluate the response of EccenAI under irregular plan geometry. Figure 8 shows the final case study, which evaluates an L-shaped floor plan measuring 25 m × 35 m and represents a commercial building scenario. Unlike the previous case studies, the structural system was intentionally arranged asymmetrically in order to investigate the effect of irregular plan geometry on eccentricity performance. The floor height was set to 3.6 m, and the reinforced concrete columns were modelled with cross-sectional dimensions of 600 mm × 750 mm. The beams were modelled with dimensions of 160 mm × 320 mm. The shear walls were designed with a uniform thickness of 300 mm.
Figure 8. L-shaped floor plan: (a) Eccentricity Check module; (b) AI Analysis Report module; (c) revision suggestion of the Auto Optimize module; (d) result of the Auto Optimize module; (e) final floor plan.
Additionally, the structural grid was distributed asymmetrically throughout the floor plan, resulting in irregular span lengths and non-uniform stiffness. The structural core was also positioned away from the geometric center, increasing the potential for an imbalance between the center of mass and the center of rigidity. As shown in Figure 8a, the analysis results indicate eccentricity ratios of 16.40% in the x-direction and 23.07% in the y-direction. Based on these results, the floor plan was classified as Score 4—Poor.
Upon reviewing the results, the eccentricity ratio in the x-direction remained within the acceptable limits defined by the code, whereas the eccentricity ratio in the y-direction exceeded the 20% threshold. The system adopts the most critical result when determining the overall structural classification and therefore assigned the plan to the Score 4—Poor category.
The supplementary eccentricity checks further confirmed the unfavorable performance. The X + 5% value reached 21.40%, while the Y + 5% value increased to 28.07%, causing both criteria to fail (Figure 8a). These findings indicate that the irregular geometry of the L-shaped plan, together with the asymmetric arrangement of structural elements and the off-center core location, significantly affects the relationship between CM and CR.
The AI Analysis Report, shown in Figure 8b, indicates that the lateral load-bearing system is significantly unbalanced. While structural walls are concentrated mainly in the southern and western sections of the floor plan, there are no perimeter-stiffening elements on the northern and eastern façades. This creates a misalignment between CM and CR, resulting in an uneven distribution of stiffness.
According to the report, the resulting asymmetry in stiffness may cause significant torsional twisting and rotational response under seismic loading. Higher deformation demands are expected along the more flexible northern and eastern edges. To reduce the impact of these effects, the system suggests adding extra shear walls or braced frames along the northern and eastern sides. It also recommends changing the structural core layout to better balance the center of rigidity and reducing stiffness in the southern and western areas. The report concludes that achieving a more symmetrical stiffness layout could substantially reduce torsional vulnerability and improve the building’s overall seismic performance.
Finally, the Auto Optimize module (Figure 8c) proposed an intervention to improve the existing design. As in the previous case study, the system recommended that a specific section of the exterior wall be converted into a shear wall so that a more balanced distribution of stiffness could be achieved (Figure 8d). Therefore, implementing the proposed intervention improved the plan’s performance score from Score 4—Poor to Score 3—Needs Improvement. Additionally, the shear wall requirement, which could not initially be met, was satisfied following this intervention. The final floor plan is shown in Figure 8e. These results demonstrate that the proposed optimization can reduce the calculated eccentricity and improve the stiffness distribution within the tested configuration.

4. Results

The results of the three case studies indicate that floor-plan geometry, core location, and shear-wall distribution influence the calculated eccentricity. Of the evaluated alternatives, the square floor plan performed best, achieving Score 1—Optimal classification, with eccentricity ratios of 1.93% and 0.61% in the x- and y-directions, respectively (Table 9). The centrally located structural core and balanced shear-wall distribution contributed to close alignment between CM and CR.
Table 9. Performance comparison of different floor-plan configurations.
In contrast, both the rectangular and L-shaped floor plans exhibited considerably higher eccentricity values and were classified as Score 4—Poor. In the rectangular plan, the offset core location caused the eccentricity in the x-direction to exceed the 20% threshold specified by the code (Table 9). The x-direction eccentricity decreased from 23.32% to 9.70%, corresponding to a reduction of approximately 58.4%. Although the y-direction eccentricity increased slightly from 1.74% to 2.20%, the critical x-direction eccentricity was substantially reduced below the 20% code threshold. Similarly, the L-shaped plan generated substantial eccentricity due to its irregular geometry and asymmetrical structural configuration, resulting in failure of both the accidental eccentricity and shear-wall compliance checks. The optimization reduced the critical y-direction eccentricity from 23.07% to 15.80%, while the x-direction eccentricity changed only slightly, from 16.40% to 16.70%. Notably, the reduction in the governing eccentricity direction was accompanied by small increases in the orthogonal direction in both optimized irregular cases, indicating that the interventions improved the critical condition without uniformly improving all directional indicators.
The AI Analysis Report successfully identified the primary causes of poor performance in both cases, including uneven stiffness distribution, insufficient lateral-load-resisting elements, and misalignment between CM and CR. Based on these findings, the Auto Optimize module proposed targeted modifications, including the conversion of portions of exterior walls into shear walls. After optimization, the rectangular plan improved from Score 4—Poor to Score 2—Good, while the L-shaped plan improved from Score 4—Poor to Score 3—Needs Improvement.
Overall, the results demonstrate that the proposed framework can screen plan-level eccentricity during early design and generate design recommendations that improve the calculated eccentricity performance. The findings also highlight the influence of stiffness distribution and core placement on CM–CR alignment.
Table 9 summarizes the characteristics, assessment results and optimization outcomes of the three case studies. The square plan performed best due to its symmetrical layout and centrally located core. In contrast, the rectangular and L-shaped plans exhibited significant eccentricity due to core displacement and stiffness imbalance. Following AI-agent optimization, both irregular plans demonstrated improved eccentricity performance. These results demonstrate the behavior of the prototype under controlled plan configurations and should not be interpreted as validation of full-scale structural performance in real building projects.

5. Discussion

The findings indicate that plan geometry, core location, and the distribution of lateral load-resisting elements have a direct influence on the relationship between the center of mass and the center of rigidity, and consequently on the calculated eccentricity. More importantly, the case studies show that these relationships can be evaluated meaningfully during the conceptual design stage, when major architectural decisions are still open to revision. In this respect, the contribution of the proposed framework is not limited to identifying whether a design satisfies a predefined eccentricity criterion; it also enables designers to interpret how alternative plan configurations influence the balance between mass and stiffness. The results therefore support the use of eccentricity as an early-stage screening indicator for potentially unfavorable plan configurations rather than as a complete representation of seismic behavior.
Unlike conventional Automated Code Compliance (ACC) systems, which primarily identify compliance or non-compliance, EccenAI combines deterministic assessment with LLM-assisted interpretation and design revision support. The distinction between these functions is central to the proposed framework. Engineering quantities such as CM, CR, eccentricity, and code-compliance results are generated by the deterministic module, whereas the LLM operates on structured assessment outputs to provide contextual explanations and candidate design modifications. This differs from many existing BIM-integrated AI systems, which are primarily oriented toward natural-language interaction, model authoring, coordination, or task automation [10,15,22,23,24,25,26,27,28,29]. By positioning the LLM as an interpretive and advisory layer rather than as the source of engineering calculations, the proposed architecture provides a clearer separation between numerical assessment and AI-supported reasoning. This separation is particularly relevant for safety-related design applications, where traceability of the underlying engineering logic is essential.
The proof-of-concept evaluation also highlights the intended scope of the framework. The controlled floor plan configurations were selected to isolate the effects of geometric asymmetry, core displacement, and stiffness distribution under interpretable design conditions. The resulting behavior was consistent with the expected influence of mass and stiffness redistribution, supporting the internal consistency of the implemented workflow. Accordingly, the present evaluation provides functional verification of the workflow rather than independent structural validation. The three cases represent conceptual test configurations rather than the diversity of real building projects, and no direct benchmarking against a comprehensive structural analysis model was conducted. Accordingly, further validation using manual calculations, established structural analysis software, and real BIM projects is required to quantify the accuracy and generalizability of the proposed assessment procedure.
The structural simplifications adopted in the deterministic module further define the limits of interpretation. The current CR calculation considers the relative stiffness contributions of reinforced-concrete columns and shear walls, while full three-dimensional structural behavior, diaphragm effects, frame interactions, and coupled seismic response are outside the present scope. Similarly, the CM calculation relies on assumptions regarding material density, live-load participation, and the inclusion of selected non-structural components. These simplifications are consistent with the intended early-stage use of the framework, where detailed structural information may not yet be available, but they may lead to deviations from results obtained through comprehensive structural analysis. The calculated eccentricity should therefore be interpreted as a comparative plan-level indicator of mass–stiffness balance rather than as a direct prediction of torsional demand or seismic response.
A further limitation concerns the reliability and repeatability of the LLM component. Although the final implementation uses structured inputs, constrained JSON outputs, a temperature of 0.0, and deterministic candidate validation to reduce output variability, repeated-run consistency was not systematically evaluated. In addition, the generated recommendations were not independently assessed by a panel of structural engineering experts. These limitations are important because consistency of language-model output cannot be assumed even under constrained prompting conditions. In the current implementation, this uncertainty is partly controlled by separating recommendation generation from engineering calculation and by subjecting candidate modifications to deterministic checks and dry-run evaluation before they are presented to the user. Nevertheless, systematic repeatability testing and expert evaluation are required before the LLM component can be considered sufficiently validated for broader professional use.
The optimization module should also be understood within the limits of the present prototype. It operates within predefined architectural and structural constraints and applies a single approved intervention in each optimization iteration. Consequently, complex or highly irregular design problems may require several iterations and continued intervention by architects and structural engineers. The framework therefore represents a semi-autonomous decision-support process rather than a fully autonomous design system. The AI agent can identify deficiencies, generate candidate interventions, and support comparative evaluation, but it does not replace professional judgment. Final assessment and approval of proposed modifications must remain with qualified architects and structural engineers, who are responsible for evaluating the broader architectural, structural, and regulatory implications of the design.

6. Conclusions

Following an iterative action-research process, this study developed and iteratively refined EccenAI as a BIM-integrated AI-agent framework designed to support early-stage assessment of plan-level seismic eccentricity and related design decision-making. The proposed framework combines deterministic, code-based calculations with LLM-assisted interpretation and design guidance within the Revit environment. EccenAI is intended as a complementary decision-support approach that introduces selected seismic performance considerations into the architectural design process while plan configuration, core location, and structural element distribution can still be revised efficiently.
The scientific contribution of the study lies in the integration of deterministic structural assessment and LLM-assisted reasoning within a single BIM-based workflow. By assigning engineering calculations and code-related evaluations to the deterministic module, while using the LLM to interpret structured outputs and generate design-oriented recommendations, the framework establishes a clear separation between numerical assessment and AI-supported reasoning. This hybrid architecture extends conventional BIM-based compliance checking toward performance-informed design support while preserving the traceability of the underlying engineering logic.
From a design and professional practice perspective, the framework suggests a way to bring selected structural considerations into architectural decision-making before detailed engineering analysis begins. Its value lies not in replacing established structural analysis procedures, but in providing an intermediate decision-support layer through which potentially unfavorable mass–stiffness relationships can be identified and reconsidered while the design remains comparatively flexible. In this sense, EccenAI supports a more continuous interaction between architectural design and structural evaluation and has the potential to reduce the need for late-stage revisions and coordination demands.
The conclusions of the study are bounded by the proof-of-concept scope and by several methodological limitations. The current implementation is restricted to plan-level assessment of reinforced-concrete systems and relies on simplified representations of mass and stiffness distribution. Full three-dimensional structural behavior, diaphragm effects, frame interaction, vertical irregularities, and coupled seismic response are outside the present scope. Certain non-structural components and loads are also simplified or excluded. In addition, the deterministic assessment has not yet been independently benchmarked against comprehensive structural analysis software, and the LLM component has not been systematically evaluated in terms of repeated-run consistency, prompt sensitivity, model dependency, or expert agreement. These limitations constrain the generalizability of the findings and define EccenAI as an early-stage screening and decision-support framework rather than a validated structural analysis method.
Future research should therefore proceed along two complementary directions: validation and methodological extension. Validation should include systematic comparison with manual calculations and established FEM-based structural analysis tools, testing on real BIM projects, and evaluation by domain experts. Methodological extension should address multi-storey buildings, additional structural systems and irregularity types, and more complex architectural conditions. The AI component should also be tested across alternative language models and controlled prompt configurations to establish the robustness and reproducibility of recommendation generation. Beyond these steps, the framework could be expanded toward multi-criteria decision support in which seismic performance is considered together with architectural, environmental, economic, and constructability objectives.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/buildings16193800/s1, Code S1: Module 1 Eccentricity Check; Code S2: Module 2 AI Analysis Report; Code S3: Module 3 Auto Optimize.

Author Contributions

Conceptualization, E.B.Ş., S.B. and S.A.; methodology, E.B.Ş., S.B. and S.A.; software, E.B.Ş.; writing—original draft preparation, E.B.Ş., S.B. and S.A.; writing—review and editing, S.B. and S.A.; visualization, E.B.Ş.; supervision, S.B. and S.A. All authors have read and agreed to the published version of the manuscript.

Funding

The article processing charge (APC) was funded by the Scientific Research Projects Coordination Unit of Istanbul Technical University (İTÜ-BAP) under project code PMA-2026-48849.

Data Availability Statement

The original contributions presented in this study are included in the article and the Supplementary Materials. Further inquiries can be directed to the corresponding author.

Acknowledgments

This study was conducted as part of a master’s thesis carried out in an Architectural Design Computing Program at the Graduate School Istanbul Technical University. During manuscript preparation, the authors used ChatGPT (GPT-5.6 Sol, OpenAI) to assist with language refinement and stylistic editing of text originally drafted by the authors. OpenAI Codex was used to assist with code development, debugging, and implementation of the proposed software framework. All AI-assisted outputs were critically reviewed, revised, and approved by the authors, who take full responsibility for the final content of the publication.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
ACCAutomated Code Compliance
AIArtificial Intelligence
APIApplication Programming Interface
BIMBuilding Information Modeling
CADComputer-Aided Design
CMCenter of Mass
CRCenter of Rigidity
FEAFinite Element Analysis
FEMFinite Element Method
LLMLarge Language Model
NLPNatural Language Processing
QOCQuestions, Options, Criteria
RCReinforced Concrete
TBDYTurkish Building Seismic Code
WPFWindows Presentation Foundation

References

  1. Khanal, B.; Chaulagain, H. Seismic Elastic Performance of L-Shaped Building Frames through Plan Irregularities. Structures 2020, 27, 22–36. [Google Scholar] [CrossRef] [Scilit]
  2. Mohod, M.V. Effect of Shape and Plan Configuration on Seismic Response of Structure. IJSTR 2015, 4, 84–88. [Google Scholar]
  3. İdemen, A.E. Bina Ağırlık Merkezi-Rijitlik Merkezi İlişkisini Mimari Tasarım Aşamasında Kuran Bir Uzman Sistem. Master’s Thesis, Istanbul Technical University, Istanbul, Türkiye, January 2003. [Google Scholar]
  4. Er Akan, A.; Bingol, K.; Örmecioğlu, H.T.; Er, A.; Örmecioğlu, T.O. Towards an Earthquake-Resistant Architectural Design with the Image Classification Method. J. Asian Archit. Build. Eng. 2024, 23, 157–170. [Google Scholar] [CrossRef] [Scilit]
  5. TBDY. Türkiye Buildings Seismic Code; Disaster and Emergency Management Authority (AFAD): Ankara, Türkiye, 2018.
  6. Balaban, Ö.; Kilimci, E.S.Y.; Çağdaş, G. Automated Code Compliance Checking Model for Fire Egress Codes. In Digital Applications in Construction; eCAADe: Prague, Czech Republic, 2012; Volume 2, pp. 117–125. [Google Scholar] [CrossRef] [Scilit]
  7. Bingöl, K.; Er Akan, A.; Örmecioğlu, H.T.; Er, A. Depreme dayanıklı mimari tasarımda yapay zeka uygulamaları: Derin öğrenme ve görüntü işleme yöntemi ile düzensiz taşıyıcı sistem tespiti. Gazi Üniversitesi Mühendis. Mimar. Fakültesi Derg. 2020, 35, 2197–2210. [Google Scholar] [CrossRef] [Scilit]
  8. Yıldırım, Ş.; Alaçam, S. An Investigation on Algorithm Aided BIM Approaches to Increase Collaboration and Optimisation in Project Phase: A Case Study. ITU A|Z J. Fac. Archit. 2018, 15, 65–77. [Google Scholar] [CrossRef] [Scilit]
  9. Koçak, C.; Alaçam, S. Algorithm Aided Design Framework for BIM: Daylight In Early Phases of Design. Estoa 2023, 12, 67–79. [Google Scholar] [CrossRef] [Scilit]
  10. Fernandes, D.; Garg, S.; Nikkel, M.; Guven, G. A GPT-Powered Assistant for Real-Time Interaction with Building Information Models. Buildings 2024, 14, 2499. [Google Scholar] [CrossRef] [Scilit]
  11. Wang, Z.; Sacks, R.; Ouyang, B.; Ying, H.; Borrmann, A. A Framework for Generic Semantic Enrichment of BIM Models. J. Comput. Civ. Eng. 2024, 38, 04023038. [Google Scholar] [CrossRef] [Scilit]
  12. Wang, Y.; Liu, Y.; Cai, H.; Wang, J.; Zhou, X. An Automated Fire Code Compliance Checking Jointly Using Building Information Models and Natural Language Processing. Fire 2023, 6, 358. [Google Scholar] [CrossRef] [Scilit]
  13. Madireddy, S.; Gao, L.; Din, Z.U.; Kim, K.; Senouci, A.; Han, Z.; Zhang, Y. Large Language Model-Driven Code Compliance Checking in Building Information Modeling. Electronics 2025, 14, 2146. [Google Scholar] [CrossRef] [Scilit]
  14. Eastman, C.; Lee, J.; Jeong, Y.; Lee, J. Automatic Rule-Based Checking of Building Designs. Autom. Constr. 2009, 18, 1011–1033. [Google Scholar] [CrossRef] [Scilit]
  15. Ying, H.; Sacks, R. From Automatic to Autonomous: A Large Language Model-Driven Approach for Generic Building Compliance Checking. In Proceedings of the 41st CIB W78 Conference, Marrakesh, Morocco, 1–3 October 2024. [Google Scholar]
  16. Solihin, W.; Eastman, C. Classification of Rules for Automated BIM Rule Checking Development. Autom. Constr. 2015, 53, 69–82. [Google Scholar] [CrossRef] [Scilit]
  17. Khattra, S.K.; Rai, H.S.; Singh, J. Towards Automated Structural Stability Design of Buildings—A BIM-Based Solution. Buildings 2022, 12, 451. [Google Scholar] [CrossRef] [Scilit]
  18. Aydın, M. Building Information Modeling Based Automated Building Regulation Compliance Checking Asp.Net Web Software. Intell. Autom. Soft Comput. 2021, 28, 11–25. [Google Scholar] [CrossRef] [Scilit]
  19. Chen, N.; Lin, X.; Jiang, H.; An, Y. Automated Building Information Modeling Compliance Check through a Large Language Model Combined with Deep Learning and Ontology. Buildings 2024, 14, 1983. [Google Scholar] [CrossRef] [Scilit]
  20. Haque, M.O.; Kim, J.B. AI-Integrated Compliance Checking in BIM to Enhance Healthcare Accessibility. In Proceedings of the Humanistic Computation and Intelligence; CAADRIA: Hsinchu, Taiwan, 2026; Volume 1, pp. 641–650. [Google Scholar]
  21. Akhavian, R.; Amani, M.; Mootz, J.; Ashe, R.; Beheshti, B. Building Information Models to Robot-Ready Site Digital Twins (BIM2RDT): An Agentic AI Safety-First Framework. arXiv 2025, arXiv:2509.20705. [Google Scholar] [CrossRef] [Scilit]
  22. Guo, P.; Xue, H.; Ma, J.; Cheng, J.C.P. Advancing BIM Information Retrieval with an LLM-Based Query-Domain-Specific Language and Library Code Function Alignment System. Autom. Constr. 2025, 178, 106374. [Google Scholar] [CrossRef] [Scilit]
  23. Dong, Y.; Zhan, Z.; Hu, Y.; Doe, D.M.; Han, Z. AI BIM Coordinator for Non-Expert Interaction in Building Design Using LLM-Driven Multi-Agent Systems. Autom. Constr. 2025, 180, 106563. [Google Scholar] [CrossRef] [Scilit]
  24. Du, C.; Esser, S.; Nousias, S.; Borrmann, A. Text2BIM: Generating Building Models Using a Large Language Model-Based Multiagent Framework. J. Comput. Civ. Eng. 2026, 40, 04025142. [Google Scholar] [CrossRef] [Scilit]
  25. Jang, S.; Lee, G.; Oh, J.; Lee, J.; Koo, B. Automated Detailing of Exterior Walls Using NADIA: Natural-Language-Based Architectural Detailing through Interaction with AI. Adv. Eng. Inform. 2024, 61, 102532. [Google Scholar] [CrossRef] [Scilit]
  26. Tang, C.; Tam, K.-M.M.; Herr, C.M. Archi-Agents: Approximating the Architectural Design Process with Collaborative Specialized Multiagent System LLM and Building Information Modeling. In Architectural Informatics; CAADRIA: Tokyo, Japan, 2025; Volume 3, pp. 141–150. [Google Scholar] [CrossRef] [Scilit]
  27. Deng, Z. Towards Autonomous BIM Authoring via GUI Agent-Based Computer Control. Master’s Thesis, Technical University of Munich, Munich, Germany, 2025. [Google Scholar]
  28. Bayer, S.; Alaçam, S.; Güzelci, O.Z. BIM–AI Integration in Architecture: A Workflow-Based Review. Bud. I Archit. Civ. Archit. Eng. 2026, 25, 26038. [Google Scholar] [CrossRef] [Scilit]
  29. Jadhav, Y.; Barati Farimani, A. Large Language Model Agent as a Mechanical Designer. J. Eng. Des. 2026, 37, 2904–2940. [Google Scholar] [CrossRef] [Scilit]
  30. Ulkucu, Y.; Alacam, S. A Decision Support Framework for FLP in the Context of Industrial Facilities by the Use of BIM. In Proceedings of the 37th eCAADe and 23rd SIGraDi Conference, Porto, Portugal, 11–13 September 2019; eCAADe: Brussels, Belgium; pp. 409–418.
  31. Dix, A.; Finlay, J.; Abowd, G.D.; Beale, R. Human-Computer Interaction, 3rd ed.; Pearson Prentice-Hall: Essex, UK, 2010. [Google Scholar]
  32. MacLean, A.; Young, R.M.; Bellotti, V.M.E.; Moran, T.P. Human-Computer Interaction; Lawrence Erlbaum Associates: Hillsdale, NJ, USA, 1991; Volume 6, pp. 201–250. [Google Scholar]
  33. EN 1991-1-1; Eurocode 1: Actions on Structures—Part 1-1: General Actions—Densities, Self-Weight, Imposed Loads for Buildings. European Committee for Standardization: Brussels, Belgium, 2002.
  34. TS ISO 9194; Bases for Design of Structures; Actions due to the Self-Weight of Structures, Non-Structural Elements and Stored Materials—Density. Turkish Standard Institute: Ankara, Türkiye, 1997.
  35. TS 498; Design Loads for Buildings. Turkish Standard Institute: Ankara, Türkiye, 2021.
  36. 23722; Planned Areas Zoning Regulation. Çevre, Şehircilik ve İklim Değişikliği Bakanlığı: Ankara, Türkiye, 2017.
  37. Onur, M.İ.; Tunaboyu, O.; Tuncan, A.; Tuncan, M. Radye Temeller için Bilgisayar Destekli Eksantrisite Hesabı. Eng. Sci. 2011, 6, 1620–1629. [Google Scholar] [CrossRef]
  38. Akyürek, O. An alternative recommendation for design eccentricity. Politek. Derg. 2023, 26, 609–623. [Google Scholar] [CrossRef] [Scilit]
  39. Hibbeler, R.C. Engineering Mechanics. Statics and Dynamics, 14th ed.; Pearson: Hoboken, NJ, USA, 2016. [Google Scholar]
  40. Darılmaz, K. Deprem Yönetmeliği Yapı Dinamiği Temel Konuları Betonarme ve Çelik Taşıyıcı Sistemler SAP2000 Çözümlü Örnekleri Python Program Kodları; Birsen Yayınevi: İstanbul, Türkiye, 2023. [Google Scholar]
  41. Google Gemini 2.5 Flash. 2025. Available online: https://ai.google.dev/gemini-api/docs/models/gemini-2.5-flash?hl=tr (accessed on 17 August 2026).
  42. Google Gemini 3.5 Flash. 2026. Available online: https://ai.google.dev/gemini-api/docs/models/gemini-3.5-flash?hl=tr (accessed on 17 August 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.