Abstract
Background: Driveline infection (DLI) is the most common device-specific infection in patients supported with ventricular assist devices (VADs) and remains a major cause of morbidity during long-term mechanical circulatory support. This study aimed to evaluate the incidence, risk factors, microbiological characteristics, and antimicrobial resistance patterns of DLIs in patients undergoing durable left ventricular assist device (LVAD) implantation. Methods: This retrospective cohort study included 772 consecutive patients who underwent durable LVAD implantation at a single tertiary center between January 2012 and December 2024. Patients were categorized according to the development of DLI: the DLI group (n = 158) and the non-DLI group (n = 614). Demographic, clinical, laboratory, perioperative, and postoperative variables were analyzed. Multivariate logistic regression analysis was performed to identify independent predictors of DLI. Microbiological isolates and antimicrobial resistance patterns were also evaluated. Results: Driveline infection developed in 20.5% of patients during follow-up. Patients with DLI had a significantly higher body mass index (26.4 vs. 24.8 kg/m2, p = 0.002) and a higher prevalence of diabetes mellitus (28.2% vs. 12.1%, p < 0.001). In multivariate analysis, diabetes mellitus (OR 3.29, p = 0.013) and longer LVAD support duration (p = 0.003) were independently associated with DLI. Device type showed differences in crude infection rates but was not an independent predictor. The most frequently isolated pathogens were Staphylococcus aureus (36%) and Pseudomonas aeruginosa (19%). The most common antimicrobial resistance patterns included fluoroquinolone resistance (23%), methicillin-resistant Staphylococcus aureus (10%), and resistance to piperacillin/tazobactam and carbapenems. Conclusions: In this large single-center cohort, diabetes mellitus and prolonged device support duration were the main independent predictors of driveline infection. Staphylococcus aureus and Pseudomonas aeruginosa were the predominant pathogens, with notable antimicrobial resistance patterns. These findings highlight the importance of metabolic optimization, meticulous driveline exit-site care, and structured long-term surveillance strategies for reducing infection risk in LVAD recipients.
1. Introduction
Ventricular assist devices (VADs) are an established therapy for patients with end-stage heart failure, leading to improved functional capacity, symptom relief, and quality of life [1]. VADs are commonly implanted as a bridge to transplant (BTT); however, an increasing proportion of patients who are ineligible for transplantation receive VADs as destination therapy (DT). Despite advances in device technology and perioperative management, VAD implantation is still associated with significant complications, including pump thrombosis, bleeding, cerebrovascular accidents (CVA), and infection [2,3].
Infection remains one of the most frequent and serious complications, affecting up to 60% of VAD recipients, and is associated with impaired quality of life, recurrent hospitalizations, and worse prognosis [4,5]. Among these, percutaneous driveline infections (DLIs) represent the most common form of VAD-specific infection and may progress to deeper infections involving the pump pocket, cannula, or device itself [6]. DLIs are prone to relapse, often necessitating repeated hospital admissions and prolonged antimicrobial therapy, thereby substantially increasing long-term healthcare costs [7,8].
Infections in VAD recipients are classified as VAD-specific, VAD-related, or non-VAD-related. VAD-specific infections directly involve device components such as the pump, cannula, pocket, or driveline, and may result from intraoperative contamination, colonization of the driveline exit site, or hematogenous seeding during bloodstream infections. Driveline infections are further categorized as superficial or deep, depending on whether the infection is limited to the skin and subcutaneous tissue or extends beyond the fascial and muscular layers. Trauma to the driveline exit site is a significant predisposing factor for infection development. Additionally, microbial adherence and biofilm formation on driveline surfaces play a central role in the pathogenesis of these infections. Microorganisms can adhere to both smooth and velour segments of the driveline, migrate along the subcutaneous tunnel, and establish biofilms that protect them from host immune responses and limit antibiotic penetration. These mechanisms contribute to persistent or recurrent infections that are often difficult to eradicate without combined medical and surgical management [9,10,11].
Staphylococcus species are the most frequently isolated pathogens in VAD-specific infections, followed by Pseudomonas aeruginosa, with other Gram-negative bacteria and Candida species also implicated [12].
In this study, we aimed to investigate driveline infections as a subset of VAD-specific infections in our patient population. The diagnosis of DLI was based on microbiological findings from swab and tissue cultures, clinical presentation, infection-related laboratory parameters, and infectious disease consultations. Owing to limited data distinguishing superficial from deep infections, all patients treated medically or undergoing surgical driveline revision were classified as having DLI.
This study seeks to identify risk factors associated with driveline infections, characterize causative microorganisms, evaluate antibiotic treatment strategies, and analyze antimicrobial resistance patterns in VAD recipients.
2. Materials and Methods
This retrospective cohort study included consecutive patients who underwent durable left ventricular assist device (LVAD) implantation at the Ege University Cardiovascular Surgery Clinic between January 2012 and December 2024. A total of 772 patients were analyzed. Patients were categorized into two groups according to the development of driveline infection (DLI): those who developed DLI (n = 158) and those who did not (n = 614).
This study included all consecutive adult patients who underwent durable LVAD implantation during the study period. Patients who underwent biventricular assist device implantation or temporary circulatory support were excluded. In addition, patients with incomplete medical records or insufficient follow-up data to determine driveline infection status were also excluded from the analysis.
The study protocol was approved by the Ege University Ethics Committee (approval number: 23-5.1T/3), and the study was conducted in accordance with the principles of the Declaration of Helsinki.
Demographic, clinical, laboratory, perioperative, and postoperative data were retrospectively extracted from institutional electronic medical records.
Baseline variables included age, sex, body mass index (BMI), hypertension, diabetes mellitus, hyperlipidemia, prior cardiac surgery, and comorbidities such as gastrointestinal bleeding, chronic obstructive pulmonary disease, and prior cerebrovascular events.
Preoperative laboratory parameters included serum creatinine, albumin, hemoglobin, international normalized ratio (INR), lactate, and leukocyte count. Heart failure severity was assessed using the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) classification. Additional preoperative variables included transpulmonary gradient, N-terminal pro-brain natriuretic peptide (NT-proBNP) levels, preoperative inotropic support, intra-aortic balloon pump (IABP) use, and extracorporeal membrane oxygenation (ECMO) support.
Surgical characteristics included the surgical approach (median sternotomy, thoracotomy, or minimally invasive techniques), the type of implanted durable LVAD, cardiopulmonary bypass (CPB) duration, aortic cross-clamp time, and concomitant surgical procedures (tricuspid valve repair, aortic valve replacement, or aortic replacement). Re-exploration due to postoperative bleeding was recorded.
Postoperative variables included the development of right heart failure, the use of inhaled nitric oxide, prolonged inotropic support (>14 days), requirement for temporary right ventricular assist device (RVAD) support (Levitronix® (Levitronix Technologies Inc., Zurich, Switzerland) or ECMO), and long-term RVAD support. Postoperative complications included acute renal failure, need for hemodialysis, sepsis, and length of intensive care unit (ICU) stay.
Long-term outcomes included gastrointestinal bleeding, ischemic and hemorrhagic stroke, pump thrombosis, the duration of LVAD support, mortality, and heart transplantation.
The diagnosis of driveline infection was established based on clinical findings (erythema, purulent discharge, local pain, or abscess formation at the exit site), microbiological culture results obtained from the driveline region, infection-related laboratory parameters, and multidisciplinary evaluation including consultation with the infectious diseases department.
Infection definitions were based on the 2024 consensus statement of the International Society for Heart and Lung Transplantation (ISHLT) for mechanical circulatory support-associated infections. Infections were classified as device-specific, device-related, and non-device-related infections. Device-specific infections included driveline, pump, cannula, and pocket infections. Driveline infection (DLI) was defined as infection involving the percutaneous driveline exit site or subcutaneous tunnel, diagnosed based on clinical signs and symptoms such as erythema, purulent discharge, local tenderness, or abscess formation, and supported by microbiological evidence and/or imaging findings when clinically indicated. Driveline infections were further categorized as superficial, limited to the skin and subcutaneous tissue, or deep, extending beyond the fascial or muscular layers. Device-related infections included bloodstream infections and endocarditis associated with the device, whereas non-device-related infections were defined as infections not directly related to the mechanical circulatory support system.
Microbiological samples included driveline exit-site swabs, tissue or biopsy specimens, and abscess material when present. When clinically indicated, additional cultures (blood, urine, sputum, or deep tracheal aspirates) were obtained to exclude systemic infection.
Due to incomplete documentation distinguishing superficial from deep driveline infections, all patients who received targeted medical treatment for DLI or underwent surgical driveline revision were classified as having driveline infection. Among the 158 patients with DLI, 10 underwent surgical driveline relocation or revision. All patients received standardized antimicrobial therapy.
Exit-site care in our institution consisted of daily sterile dressing changes using chlorhexidine-based antiseptic solutions.
At our center, empirical therapy for suspected driveline infections is guided by the most recent cumulative antibiogram data, individual patient characteristics, prior microbiological results, and clinical severity at presentation. Particular consideration is given to risk factors for multidrug-resistant (MDR) pathogens, including prior broad-spectrum antibiotic exposure, prolonged or repeated hospitalization, intensive care unit (ICU) stay, previous colonization or infection with resistant organisms, and recent device-related interventions.
In clinically stable patients without MDR risk, empirical therapy consists of a beta-lactam active against methicillin-susceptible Staphylococcus aureus (MSSA) and Enterobacterales spp. In patients presenting with severe infection, prior broad-spectrum antibiotic exposure, prolonged hospitalization, or known colonization with resistant organisms, broader anti-pseudomonal coverage is initiated. Empirical coverage against methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-resistant coagulase-negative staphylococci (MR-CoNS) is added when clinically or epidemiologically indicated.
Antimicrobial therapy is reassessed within 48–72 h and de-escalated according to microbiological results, with surgical source control performed when necessary.
Isolated microorganisms were identified using standard institutional microbiological techniques. Antimicrobial susceptibility testing was performed according to institutional laboratory protocols, and resistance patterns of isolated pathogens were recorded and analyzed.
Episode-level infection data were not consistently available for all patients, limiting formal recurrence and time-to-reinfection analyses.
2.1. Statistical Methods
Statistical analyses were performed using the IBM Statistical Package for the Social Sciences (SPSS) for macOS, version 30.0 (IBM Corp., Armonk, NY, USA). Categorical variables were expressed as frequencies and percentages, while continuous variables were presented as mean ± standard deviation or median (minimum–maximum), as appropriate. The normality of continuous variables was assessed using the Kolmogorov–Smirnov test.
For intergroup comparisons, the Mann–Whitney U test was used for continuous variables, and the chi-square test or Fisher’s exact test was applied for categorical variables. A p-value < 0.05 was considered statistically significant.
2.2. Logistic Regression Analysis
Multivariate logistic regression analysis was performed to identify independent factors associated with driveline infection. Variables considered clinically relevant, as well as those associated with DLI in univariate analyses (p < 0.10), were included as candidate variables. Age and sex were entered into the model as principal covariates. Variables with no events in the DLI group were excluded to ensure model stability.
The final model included age, sex, body mass index, diabetes mellitus, device type, reoperation due to bleeding, postoperative nitric oxide use, length of stay in the intensive care unit, and total duration of device support. All selected variables were entered simultaneously into the model using the enter method to maintain clinical interpretability. Adjusted odds ratios (ORs) with corresponding 95% confidence intervals (CIs) were reported, and statistical significance was defined as p < 0.05.
3. Results
A total of 641 patients (83%) were male and 131 (17%) were female. Among patients who developed driveline infection, 126 (79.7%) were male and 32 (20.3%) were female. The mean age was 53 years in both groups. Mean body mass index was significantly higher in patients with driveline infection compared with those without infection (26.4 vs. 24.8, p = 0.002).
Dilated cardiomyopathy was the most common underlying diagnosis in both groups, observed in 318 patients (52.9%) without driveline infection and 80 patients (51%) with driveline infection. Diabetes mellitus was significantly more prevalent among patients with driveline infection (28.2% vs. 12.1%, p < 0.001). Hyperlipidemia was more frequently observed in patients with driveline infection (12.8% vs. 6.2%, p = 0.009).
Other evaluated baseline characteristics, including peripheral arterial disease, chronic obstructive pulmonary disease, gastrointestinal bleeding, cerebrovascular accident, preoperative hemodialysis, and preoperative laboratory parameters (pro-BNP, creatinine, bilirubin, INR, albumin, hemoglobin, and leukocyte count), did not differ significantly between groups. Baseline demographic and clinical characteristics are summarized in Table 1.
Table 1.
Patients’ diagnosis, comorbidities, preoperative demographics, and laboratory data.
No significant differences were observed between groups regarding prior cardiac surgery, preoperative lactate levels, preoperative inotropic support, INTERMACS classification, preoperative intra-aortic balloon pump use, or preoperative extracorporeal membrane oxygenation support (Table 2).
Table 2.
Comparison of Preoperative Characteristics in Patients With and Without Driveline Infection.
A significant difference in driveline infection rates was observed according to device type. Driveline infection occurred in approximately 18% of patients with the HeartWare (Medtronic, Inc., Minneapolis, MN, USA) (HVAD), 22% of patients with the HeartMate II (Abbott Inc., Abbott Park, IL, USA), and 34% of patients with the HeartMate 3 (Abbott Inc., Abbott Park, IL, USA) device (Table 3).
Table 3.
Comparison of ventricular assist devices in terms of driveline infection.
Comparison of surgical characteristics, including surgical approach (sternotomy, thoracotomy, or minimally invasive techniques), cardiopulmonary bypass duration, aortic cross-clamp time, and concomitant surgical procedures (tricuspid valve repair, aortic valve replacement, or aortic replacement), revealed no statistically significant differences between groups (Table 4).
Table 4.
Comparison of surgical method, cardiopulmonary bypass (CPB) time, cross-clamp (X-Clamp) time, and additional surgery during the operation.
Reoperation due to postoperative bleeding occurred in 9.2% of patients without driveline infection and 3.8% of patients with driveline infection. Postoperative nitric oxide use was observed in 20.5% of patients without driveline infection and 10.8% of those with driveline infection. Temporary postoperative RVAD support (Levitronix® (Levitronix Technologies Inc., Zurich, Switzerland) or ECMO) and postoperative hemodialysis were observed only in patients without driveline infection.
The median length of stay in the intensive care unit was significantly longer in patients with driveline infection (5 [2–60] days) compared with those without infection (5 [1–60] days; p = 0.038). Total duration of LVAD support was also significantly longer in patients with driveline infection (1995.5 vs. 870.5 days, p < 0.001).
No statistically significant differences were observed between groups regarding postoperative right heart failure, prolonged inotropic support (>14 days), long-term RVAD support, postoperative complications (acute renal failure, sepsis), or long-term complications, including gastrointestinal bleeding, ischemic stroke, hemorrhagic stroke, and pump thrombosis (Table 5).
Table 5.
Comparison of postoperative revision, long-term complications, short-time complications, right heart failure, RVAD long-term, temporary RVAD (Levitronix or ECMO), postop nitric oxide, total support time (day), heart transplant, and exitus.
Multivariate analysis demonstrated that diabetes mellitus was independently associated with driveline infection, conferring approximately a threefold increased risk (p = 0.013) and longer device support duration was significantly associated with increased infection risk (p = 0.003). Higher body mass index also showed a trend toward increased risk (p = 0.066). Age, sex, device type, reoperation due to bleeding, nitric oxide use, and intensive care unit length of stay were not independently associated with driveline infection (Table 6).
Table 6.
Multivariable analysis of independent predictors of driveline infection.
Among patients with driveline infection, 79.7% (n = 126) were male and 20.3% (n = 32) were female. A total of 1624 microbiological samples were obtained from 158 patients. Swab cultures constituted the most common sample type (63.7%, n = 1035) (Table 7).
Table 7.
Demographic characteristics of patients with drive-line infection and distribution of submitted culture samples.
The most frequently isolated pathogens were Staphylococcus aureus (36%), followed by Pseudomonas aeruginosa (19%), Escherichia coli (6%), Klebsiella pneumoniae (6%), and Corynebacterium striatum (3%). Ciprofloxacin (fluoroquinolone) resistance was observed in 23% of isolates, methicillin-resistant Staphylococcus aureus (MRSA) in 10%, piperacillin/tazobactam (penicillins, including beta-lactamase inhibitors) resistance in 10%, penicillin resistance in 9%, and imipenem (Carbapenem) resistance in 8% (Table 8).
Table 8.
The Most Common Pathogens in Patients and the Distribution of Antibiotic Resistance.
In addition to patient-level analysis, infection burden was further evaluated in terms of recurrent infection-related hospitalizations and episode frequency. A total of 89 patients (11.5% of the entire cohort) experienced recurrent driveline infection-related hospitalizations. Overall, 234 infection episodes were identified during the follow-up period, corresponding to 0.076 episodes per patient-year based on 3070 patient-years of observation. Therefore, a formal time-to-reinfection or recurrent-event analysis was not performed due to insufficiently reliable episode-level data.
Surgical Outcomes of Patients with Deep Driveline Infection
A total of 10 patients with deep driveline infections requiring surgical intervention were analyzed. The majority of patients were male (8/10), with a median age of 43 years. Diabetes mellitus was present in two patients. The time to infection varied widely, ranging from 10 days to 29 months. All patients had received prior antibiotic therapy; however, conservative management failed to achieve infection control. Clinically, all patients presented with drainage and tenderness, while erythema was observed in most patients (8 patients) and soft tissue infiltration in some (5 patients). The infection was predominantly localized (9/10), with only one patient exhibiting systemic signs.
All patients underwent surgical debridement. Deep tissue involvement (8 patients) and driveline exposure (9 patients) were identified in the majority of cases. Additionally, flap reconstruction was performed in six patients, and driveline repositioning in five patients. Negative Pressure Wound Therapy (NPWT) was used in a limited number of patients. Microbiologically, the most common pathogen was Methicillin-Susceptible Staphylococcus aureus (MSSA) (7 patients), followed by Pseudomonas aeruginosa (2 patients) and Serratia marcescens (1 patient).
In the postoperative period, local surgical complications (bleeding, hematoma) occurred in only three patients. Eight patients required hospital readmission, and six patients underwent reoperation.
4. Discussion
Driveline infection (DLI) remains the most common device-specific infection in patients supported with ventricular assist devices (VADs). Occurring at the percutaneous exit site of the driveline connecting the implanted pump to the external controller, DLI is associated with substantial morbidity and mortality. Management remains challenging due to difficulties in achieving adequate source control, particularly in the presence of biofilm formation and antimicrobial resistance, which often lead to recurrent or chronic infection requiring prolonged suppressive therapy, surgical revision, pump exchange, or transplantation. Although early postoperative vulnerability is recognized, cumulative exposure over time significantly increases infection risk [11,13].
Previously described risk factors include younger age, obesity, diabetes mellitus, chronic kidney disease, depression, longer duration of VAD support, lower cardiac index, advanced heart failure severity, and mechanical trauma at the driveline exit site [11].
In our study, body mass index (BMI) was significantly higher among patients who developed DLI. Although BMI did not remain an independent predictor in multivariate analysis, it demonstrated a trend toward increased risk. Obesity may impair wound healing, increase mechanical stress at the exit site, and facilitate bacterial colonization, findings consistent with prior reports [14].
Diabetes mellitus was significantly more prevalent in the DLI group. Multivariate analysis confirmed diabetes mellitus as an independent predictor of driveline infection. Given the well-established effects of chronic hyperglycemia on immune dysfunction, impaired angiogenesis, reduced tissue perfusion, and delayed wound healing, diabetes represents a clinically relevant contributor to DLI susceptibility [15,16]. These findings underscore the importance of strict glycemic control in VAD recipients.
Hyperlipidemia was more frequent among patients with DLI (12.8% vs. 6.2%, p = 0.009). Although its effect was attenuated after adjustment for confounders, impaired tissue perfusion, chronic inflammation, and delayed healing associated with dyslipidemia may contribute to exit-site vulnerability.
Thromboembolic events remain major complications in VAD recipients. Data from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) have shown a higher prevalence of cerebrovascular accidents in patients with active infection compared with those without infection [17]. However, we did not observe a significant association between DLI and cerebrovascular events. Differences in infection timing, definitions, and study design may explain this discrepancy, suggesting that localized driveline infection alone may not independently increase cerebrovascular risk.
Gastrointestinal bleeding is another well-recognized complication in LVAD recipients, with cumulative incidences of 18%, 23%, and 27% at 1, 2, and 3 years post-implantation, respectively, according to INTERMACS reports [18]. Although infection may theoretically influence coagulation balance and INR variability in patients receiving warfarin and acetylsalicylic acid, current evidence does not support a direct causal relationship between DLI and gastrointestinal bleeding. Consistent with the literature, we found no significant association.
Preoperative clinical and laboratory parameters—including peripheral arterial disease, chronic obstructive pulmonary disease, pro-BNP, bilirubin, INR, albumin, hemoglobin, leukocyte count, creatinine, and dialysis requirement—were not independently associated with DLI [19]. Similarly, preoperative INTERMACS classification did not predict infection risk, supporting the concept that DLI is multifactorial rather than determined by isolated baseline variables [13].
Redo cardiac surgery was not associated with DLI in our cohort. Although repeated procedures increase device-related infection risk in pacemaker and ICD populations [20], this relationship has not been clearly demonstrated in VAD recipients. Likewise, preoperative lactate levels, inotropic support, intra-aortic balloon pump (IABP) use, and extracorporeal membrane oxygenation (ECMO) were not significant predictors, indicating that markers of hemodynamic instability do not specifically predispose patients to DLI [21,22,23].
Device type appeared to influence infection rates. DLI incidence was approximately 18% with HeartWare (Medtronic, Inc., Minneapolis, MN, USA), 22% with HeartMate 2 (Abbott Inc., Abbott Park, IL, USA), and 34% with HeartMate 3 (Abbott Inc., Abbott Park, IL, USA) in our cohort. Meta-analytic data have reported weighted mean DLI rates ranging from 7.2% for HeartMate 2 (Abbott Inc., Abbott Park, IL, USA) to 11.9% for HeartMate 3 (Abbott Inc., Abbott Park, IL, USA) [24], and single-center studies have similarly suggested device-specific differences [25,26]. The higher incidence observed in HeartMate 3 (Abbott Inc., Abbott Park, IL, USA) recipients may relate to driveline design characteristics, including a heavier and modular structure that may complicate stabilization [27]. Differences in implantation era and support duration may also contribute and should be considered when interpreting these findings.
Intraoperative variables—including surgical approach, cardiopulmonary bypass time, cross-clamp time, and concomitant procedures—were not associated with DLI, suggesting that infection risk is primarily influenced by patient-related and local exit-site factors rather than operative technique.
Postoperative factors demonstrated mixed findings. Reoperation for bleeding, nitric oxide therapy, temporary RVAD support (including Levitronix® (Levitronix Technologies Inc., Zurich, Switzerland) or ECMO), and postoperative hemodialysis were not associated with increased DLI risk [28,29]. Although patients requiring dialysis are often critically ill, neither prior literature nor our data support a predisposing effect.
Prolonged ICU stay was associated with DLI. Although median ICU duration was similar between groups, patients who developed infection demonstrated a broader distribution with a higher proportion of extended stays (p = 0.038), supporting prior observations linking prolonged hospitalization to infection risk [30].
Duration of VAD support emerged as one of the strongest predictors of DLI. Patients with infection had significantly longer support times, and multivariate analysis confirmed total support duration as an independent predictor (p = 0.003). Previous studies have demonstrated increased infection incidence beyond 90–180 days, with a median time to infection of approximately 6.5 months [30,31]. These findings reinforce the cumulative temporal risk associated with prolonged device support.
Right heart failure, prolonged inotropic therapy (≥14 days), and postoperative sepsis were not independently associated with DLI. Although DLI may coexist with sepsis in a substantial proportion of cases [29], we did not demonstrate a statistically significant relationship, possibly reflecting differences in timing and event classification.
VAD-related infections have also been linked to adverse neurological outcomes. In a cohort of 402 patients, VAD infection occurred in 39% of cases, with driveline infections accounting for 17% [32]. Infection-related stroke was observed in 13% of infected patients; ischemic stroke was associated with wound infection, and hemorrhagic stroke was associated with bloodstream infection, while no association was found with driveline or pump pocket infection. Other studies have shown that VAD infections, particularly bloodstream infections, are associated with pump thrombosis, bleeding complications, prolonged hospitalization, reduced transplantation rates, and increased mortality [33]. Although small case series have suggested a possible link between active driveline infection and intracranial hemorrhage [34], our study did not identify an association between driveline infection and long-term complications such as gastrointestinal bleeding, ischemic stroke, hemorrhagic stroke, or pump thrombosis.
Microbiologically, our findings align with previous reports [35,36,37,38,39]. Staphylococcus aureus (36%) and Pseudomonas aeruginosa (19%) were the most frequently isolated pathogens. Resistance patterns included fluoroquinolone resistance (23%), methicillin-resistant Staphylococcus aureus (10%), and resistance to piperacillin/tazobactam and imipenem. These data underscore the ongoing challenge of antimicrobial resistance and biofilm-associated infection in VAD recipients.
5. Conclusions
In our cohort, prolonged device support duration and diabetes mellitus independently emerged as the most consistent predictors of driveline infection. Staphylococcus aureus and Pseudomonas aeruginosa were the predominant pathogens, and fluoroquinolone resistance represented the most frequent antimicrobial resistance pattern. Within the limits of this retrospective analysis, isolated driveline infection was not associated with major long-term adverse events. These findings emphasize the importance of metabolic optimization, meticulous exit-site management, and structured long-term surveillance strategies in patients receiving durable VAD support.
6. Limitations
This study has several limitations that should be acknowledged. First, its retrospective and single-center design inherently limits causal inference and introduces potential selection bias and missing data. In addition, the long study period (2012–2024) and heterogeneity in device types and management strategies used may have introduced variability in outcomes and clinical practice patterns.
Second, detailed information regarding driveline exit-site care, including hygiene adherence, dressing change frequency, stabilization techniques, and local trauma, was not systematically recorded and therefore could not be included in the analysis. Similarly, data on glycemic control and metabolic status (e.g., HbA1c levels and perioperative glucose variability) were incomplete, limiting evaluation of the role of diabetes-related metabolic control in infection risk.
Third, due to incomplete retrospective documentation, superficial and deep driveline infections could not be consistently distinguished. Therefore, classification relied on clinical, microbiological, laboratory, and infectious disease consultation data. While this approach may have led to the potential overestimation of infection incidence, it reflects real-world clinical decision-making.
Fourth, in a subset of patients, the exact timing of initial or recurrent driveline infections could not be reliably determined. Additionally, some patients initially treated at our center were later followed at external institutions and subsequently re-admitted. As a result, time-to-event analyses such as Kaplan–Meier and Cox regression could not be performed, limiting assessment of temporal trends and era effects.
Fifth, some infection episodes were inconsistently documented, which limited our ability to clearly distinguish whether infections represented persistent, relapsing, or separate new episodes. Consequently, formal recurrent-event analyses could not be conducted. Moreover, detailed longitudinal data on antibiotic duration, treatment sequencing, and relapse outcomes were not consistently available, limiting evaluation of treatment-specific effects.
Despite these limitations, this study represents one of the largest single-center experiences evaluating driveline infections over a long-term follow-up period and provides valuable real-world data on risk factors, microbiology, and outcomes in VAD patients.
Author Contributions
Conceptualization, U.K. and T.Y.; Methodology, U.K., A.Y.K. and T.Y.; Software, U.K., O.N.T. and T.Y.; Validation, U.K., A.Y.K. and T.Y.; Formal analysis, U.K., O.N.T. and T.Y.; Investigation, U.K., O.A., B.D.B. and T.Y.; Resources, U.K., O.A., B.D.B. and T.Y.; Data curation, U.K., O.A., B.D.B. and T.Y.; Writing—original draft, U.K. and T.Y.; Writing—review & editing, U.K. and T.Y.; Visualization, U.K., A.Y.K., O.N.T., M.T., S.N., E.O., C.E., M.O. and T.Y.; Supervision, U.K., M.T., S.N., E.O., C.E., M.O. and T.Y.; Project administration, U.K., M.T., S.N., E.O., C.E., M.O. and T.Y. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
The study protocol was approved by the Ege University Ethics Committee (approval number: 23-5.1T/3), with approval received on 25 May 2023, and the study was conducted in accordance with the principles of the Declaration of Helsinki.
Informed Consent Statement
Informed consent was obtained from all patients involved in the study.
Data Availability Statement
The data are available within the article.
Acknowledgments
The authors gratefully acknowledge our VAD coordinators, Derya Kayıhan and Mehtap Seymen, for their collaboration in providing exceptional patient care within the Department of Cardiovascular Surgery at the Ege University Faculty of Medicine.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
| VAD | Ventricular assist device |
| BTT | bridge to transplant |
| DT | destination therapy |
| CVA | cerebrovascular accident |
| DLI | driveline infection |
| LVAD | left ventricular assist device |
| BMI | body mass index |
| INR | international normalized ratio |
| INTERMACS | Interagency Registry for Mechanically Assisted Circulatory Support |
| NT-proBNP | N-terminal pro-brain natriuretic peptide |
| IABP | intra-aortic balloon pump |
| ECMO | extracorporeal membrane oxygenation |
| CPB | cardiopulmonary bypass |
| ICU | intensive care unit |
| RVAD | right ventricular assist device |
| MDR | multidrug-resistant |
| MSSA | methicillin-susceptible Staphylococcus aureus |
| MRSA | methicillin-resistant Staphylococcus aureus |
| MR-CoNS | methicillin-resistant coagulase-negative staphylococci MR-CoNS |
References
- Genovese, E.A.; Dew, M.A.; Teuteberg, J.J.; Simon, M.A.; Kay, J.; Siegenthaler, M.P.; Bhama, J.K.; Bermudez, C.A.; Lockard, K.L.; Winowich, S.; et al. Incidence and Patterns of Adverse Event Onset During the First 60 Days After Ventricular Assist Device Implantation. Ann. Thorac. Surg. 2009, 88, 1162–1170. [Google Scholar] [CrossRef] [Scilit]
- Kusne, S.; Mooney, M.; Danziger-Isakov, L.; Kaan, A.; Lund, L.H.; Lyster, H.; Wieselthaler, G.; Aslam, S.; Cagliostro, B.; Chen, J.; et al. An ISHLT Consensus Document for Prevention and Management Strategies for Mechanical Circulatory Support Infection. J. Heart Lung Transplant. 2017, 36, 1137–1153. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Aggarwal, A.; Gupta, A.; Kumar, S.; Baumblatt, J.A.; Pauwaa, S.; Gallagher, C.; Treitman, A.; Pappas, P.; Tatooles, A.; Bhat, G. Are Bloodstream Infections Associated with an Increased Risk of Hemorrhagic Stroke in Patients with a Left Ventricular Assist Device? ASAIO J. 2012, 58, 509–513. [Google Scholar] [CrossRef] [Scilit]
- de By, T.M.; Mohacsi, P.; Gummert, J.; Bushnaq, H.; Krabatsch, T.; Gustafsson, F.; Leprince, P.; Martinelli, L.; Meyns, B.; Morshuis, M.; et al. The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): First Annual Report. Eur. J. Cardiothorac. Surg. 2015, 47, 770–776. [Google Scholar] [CrossRef] [Scilit]
- Kirklin, J.K.; Naftel, D.C.; Pagani, F.D.; Kormos, R.L.; Stevenson, L.W.; Blume, E.D.; Myers, S.L.; Miller, M.A.; Baldwin, J.T.; Young, J.B. Seventh INTERMACS Annual Report: 15,000 Patients and Counting. J. Heart Lung Transplant. 2015, 34, 1495–1504. [Google Scholar] [CrossRef] [Scilit]
- Hannan, M.M.; Husain, S.; Mattner, F.; Danziger-Isakov, L.; Drew, R.J.; Corey, G.R.; Schueler, S.; Holman, W.L.; Lawler, L.P.; Gordon, S.M.; et al. Working Formulation for the Standardization of Definitions of Infections in Patients Using Ventricular Assist Devices. J. Heart Lung Transplant. 2011, 30, 375–384. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Nienaber, J.J.; Kusne, S.; Riaz, T.; Walker, R.C.; Baddour, L.M.; Wright, A.J.; Park, S.J.; Vikram, H.R.; Keating, M.R.; Arabia, F.A.; et al. Clinical Manifestations and Management of Left Ventricular Assist Device–Associated Infections. Clin. Infect. Dis. 2013, 57, 1438–1448. [Google Scholar] [CrossRef] [Scilit]
- Baras Shreibati, J.; Goldhaber-Fiebert, J.D.; Banerjee, D.; Owens, D.K.; Hlatky, M.A. Cost-Effectiveness of Left Ventricular Assist Devices in Ambulatory Patients with Advanced Heart Failure. JACC Heart Fail. 2017, 5, 110–119. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gordon, R.J.; Quagliarello, B.; Lowy, F.D. Ventricular Assist Device–Related Infections. Lancet Infect. Dis. 2006, 6, 426–437. [Google Scholar] [CrossRef] [Scilit]
- Califano, S.; Pagani, F.D.; Malani, P.N. Left Ventricular Assist Device–Associated Infections. Infect. Dis. Clin. N. Am. 2012, 26, 77–87. [Google Scholar] [CrossRef] [Scilit]
- Krzelj, K.; Petricevic, M.; Gasparovic, H.; Biocina, B.; McGiffin, D. Ventricular Assist Device Driveline Infections: A Systematic Review. Thorac. Cardiovasc. Surg. 2022, 70, 493–504. [Google Scholar] [CrossRef] [Scilit]
- Aslam, S. Ventricular Assist Device Infections. Cardiol. Clin. 2018, 36, 507–517. [Google Scholar] [CrossRef] [Scilit]
- Madden, A.; Moser, M.; Eisen, H. Investigating Potential Preoperative Risk Factors for Left Ventricular Assist Device Driveline Infections. Curr. Cardiol. Rep. 2025, 27, 117. [Google Scholar] [CrossRef] [Scilit]
- Akay, M.H.; Nathan, S.S.; Radovancevic, R.; Poglajen, G.; Jezovnik, M.K.; Candelaria, I.N.; Averill, B.L.; Patel, M.K.; Kar, B.; Gregoric, I.D. Obesity Is Associated with Driveline Infection of Left Ventricular Assist Devices. ASAIO J. 2019, 65, 678–682. [Google Scholar] [CrossRef] [Scilit]
- Demirbaş, Z.E.; Öcalmaz, M.Ş.; Tekin, G.; Sargın, M. Evaluation of Driveline Infections in Diabetic Patients with Left Ventricular Assist Devices. GKDA Derg. 2024, 30, 145–150. [Google Scholar] [CrossRef] [Scilit]
- Duty, E. Infection Risk Associated with Left Ventricular Assist Device Implantation and Diabetes Mellitus: An Integrative Review. Bachelor’s Thesis, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA, 2025. [Google Scholar] [CrossRef]
- Zijderhand, C.F.; Antonides, C.F.J.; Veen, K.M.; Verkaik, N.J.; Schoenrath, F.; Gummert, J.; Nemec, P.; Merkely, B.; Musumeci, F.; Meyns, B.; et al. Left Ventricular Assist Device–Related Infections and the Risk of Cerebrovascular Accidents: A EUROMACS Study. Eur. J. Cardiothorac. Surg. 2022, 62, ezac421. [Google Scholar] [CrossRef] [Scilit]
- Hammer, Y.; Bitar, A.; Aaronson, K.D. Gastrointestinal Bleeding on Continuous-Flow Left Ventricular Assist Device Therapy. ESC Heart Fail. 2023, 10, 2214–2224. [Google Scholar] [CrossRef] [Scilit]
- Köhler, A.K.; Körperich, H.; Morshuis, M.; Freytag, C.C.; Gummert, J.; Burchert, W.; Preuss, R.; Körfer, J. Pre-Operative Risk Factors for Driveline Infection in Left Ventricular Assist Device Patients. ESC Heart Fail. 2022, 9, 3995–4002. [Google Scholar] [CrossRef] [Scilit]
- Morani, G.; Mugnai, G.; Bolzan, B.; Morosato, M.; Tomasi, L.; Ferrari, S.; Vassanelli, C. Redo Procedures and Chronic Renal Dysfunction Are Associated with Higher Risk of Cardiac Electronic Device Infections. Minerva Cardioangiol. 2018, 66, 225–232. [Google Scholar] [CrossRef] [Scilit]
- Akin, S.; Soliman, O.; de By, T.M.M.H.; Muslem, R.; Tijssen, J.G.P.; Schoenrath, F.; Meyns, B.; Gummert, J.F.; Mohacsi, P.; Caliskan, K. Causes and Predictors of Early Mortality in Patients Treated with Left Ventricular Assist Device Implantation in EUROMACS. Intensive Care Med. 2020, 46, 1349–1360. [Google Scholar] [CrossRef] [Scilit]
- Bernhardt, A.M.; Copeland, H.; Deswal, A.; Gluck, J.; Givertz, M.M. ISHLT/HFSA Guideline on Acute Mechanical Circulatory Support. J. Heart Lung Transplant. 2023, 42, E1–E64. [Google Scholar] [CrossRef] [Scilit]
- Pienta, M.J.; Shore, S.; Watt, T.M.F.; Yost, G.; Townsend, W.; Cabrera, L.; Fetters, M.D.; Chenoweth, C.; Aaronson, K.; Pagani, F.D.; et al. Patient Factors Associated with Left Ventricular Assist Device Infections: A Scoping Review. J. Heart Lung Transplant. 2022, 41, 425–433. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kranzl, M.; Stoiber, M.; Schaefer, A.K.; Riebandt, J.; Wiedemann, D.; Marko, C.; Laufer, G.; Zimpfer, D.; Schima, H.; Schlöglhofer, T. Driveline Features as Risk Factor for Infection in Left Ventricular Assist Devices. Front. Cardiovasc. Med. 2021, 8, 784208. [Google Scholar] [CrossRef] [Scilit]
- Juraszek, A.; Smólski, M.; Kołsut, P.; Szymański, J.; Litwiński, P.; Kuśmierski, K.; Zakrzewska-Koperska, J.; Sterliński, M.; Dziodzio, T.; Kuśmierczyk, M. Prevalence and Management of Driveline Infections in Mechanical Circulatory Support. J. Cardiothorac. Surg. 2021, 16, 216. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schlöglhofer, T.; Michalovics, P.; Riebandt, J.; Angleitner, P.; Stoiber, M.; Laufer, G.; Schima, H.; Wiedemann, D.; Zimpfer, D.; Moscato, F. Left Ventricular Assist Device Driveline Infections in Three Contemporary Devices. Artif. Organs 2021, 45, 464–472. [Google Scholar] [CrossRef] [Scilit]
- Malkoun, A.R.; Hoffman, R.O.; Feldman, D.; Vierecke, J. Incidence of Driveline Infections in HeartMate 3 Compared to HeartMate 2. ASAIO J. 2021, 67, EPCardiac36. Available online: https://asaio.org/conference/program/2021/EPCardiac36.cgi (accessed on 18 April 2026).
- Angleitner, P.; Simon, P.; Kaider, A.; Wiedemann, D.; Dimitrov, K.; Schlöglhofer, T.; Rajek, M.A.; Riebandt, J.; Laufer, G.; Zimpfer, D. Impact of Bleeding Revision on Outcomes After Left Ventricular Assist Device Implantation. Ann. Thorac. Surg. 2019, 108, 517–523. [Google Scholar] [CrossRef] [Scilit]
- Rahal, A.; Ruch, Y.; Meyer, N.; Perrier, S.; Minh, T.H.; Schneider, C.; Lavigne, T.; Marguerite, S.; Ajob, G.; Cristinar, M.; et al. Left Ventricular Assist Device–Associated Infections: Incidence and Risk Factors. J. Thorac. Dis. 2020, 12, 2654–2662. [Google Scholar] [CrossRef] [Scilit]
- Bejko, J.; Toto, F.; Gregori, D.; Gerosa, G.; Bottio, T. Left Ventricular Assist Devices and Driveline Infection Incidence: A Single-Centre Experience. J. Artif. Organs 2018, 21, 52–60. [Google Scholar] [CrossRef] [Scilit]
- Cholewa, K.; Kurtyka, P.; Szuber-Dynia, A.; Kapis, A.; Gawlikowski, M. Local Infections Associated with Ventricular Assist Devices: Materials-Related Challenges and Emerging Solutions. Materials 2025, 18, 4541. [Google Scholar] [CrossRef] [Scilit]
- Cho, S.M.; Moazami, N.; Katz, S.; Bhimraj, A.; Shrestha, N.K.; Frontera, J.A. Stroke Risk Following Infection in Patients with Continuous-Flow Left Ventricular Assist Device. Neurocrit. Care 2019, 31, 72–80. [Google Scholar] [CrossRef] [Scilit]
- Trachtenberg, B.H.; Cordero-Reyes, A.M.; Aldeiri, M.; Alvarez, P.; Bhimaraj, A.; Ashrith, G.; Elias, B.; Suarez, E.E.; Bruckner, B.; Loebe, M.; et al. Persistent Bloodstream Infection in Patients Supported with a Continuous-Flow Left Ventricular Assist Device Is Associated with an Increased Risk of Cerebrovascular Accidents. J. Card. Fail. 2015, 21, 119–125. [Google Scholar] [CrossRef] [Scilit]
- Prince, A.J.; Domenico, C.M.; Shore, S.; Urgo, K.A.; Atluri, P.; Wald, J.W.; Birati, E.Y. Ventricular Assist Device Driveline Infection and Development of Intracranial Hemorrhage: A Case Series. ASAIO J. 2021, 67, e198–e200. [Google Scholar] [CrossRef] [Scilit]
- Siméon, S.; Flécher, E.; Revest, M.; Niculescu, M.; Roussel, J.C.; Michel, M.; Leprince, P.; Tattevin, P. Left Ventricular Assist Device–Related Infections: A Multicentric Study. Clin. Microbiol. Infect. 2017, 23, 748–751. [Google Scholar] [CrossRef] [Scilit]
- Dettbarn, E.; Prenga, M.; Stein, J.; Müller, M.; Hoermandinger, C.; Schoenrath, F.; Falk, V.; Potapov, E.; Mulzer, J.; Knierim, J. Driveline Infections in Left Ventricular Assist Devices: Incidence, Epidemiology, and Staging Proposal. Artif. Organs 2024, 48, 83–90. [Google Scholar] [CrossRef] [Scilit]
- Sarı, N.; Ateş, E.; Erol, Ç.; Kurt-Azap, Ö.; Sezgin, A. A Critical Challenge in the Heart Transplant Process: Left Ventricular Assist Device Infections. Klimik Derg. 2025, 38, 45–50. [Google Scholar] [CrossRef] [Scilit]
- Zinoviev, R.; Lippincott, C.K.; Keller, S.C.; Gilotra, N.A. In Full Flow: Left Ventricular Assist Device Infections in the Modern Era. Open Forum Infect. Dis. 2020, 7, ofaa124. [Google Scholar] [CrossRef] [Scilit]
- Hupe, J.; Worthmann, H.; Ravenberg, K.K.; Grosse, G.M.; Ernst, J.; Haverich, A.; Bengel, F.M.; Weissenborn, K.; Schmitto, J.D.; Hanke, J.S.; et al. Interplay between Driveline Infection, Vessel Wall Inflammation, Cerebrovascular Events and Mortality in Patients with Left Ventricular Assist Device. Sci. Rep. 2023, 13, 18552. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.