Error in Figure
In the original publication [1], there were mistakes in Figures 1 and 2 as published. The corrected Figure 1 and Figure 2 appear below.
Figure 1.
Overall comparison of sensitivity for detecting factor deficiencies (SDFD) by mean SDFD values among three activators. (A) FII; (B) FV; (C) FVIII; (D) FIX; (E) FX; (F) FXI; (G) FXII. Data are mean ± SD (n = 3 independent experiments). A two-way repeated-measures mixed model with Tukey’s test was used. Mean SDFD value for each activator was derived from all activity levels. Only comparisons with significant differences are indicated by connecting lines and asterisks. Significance levels: * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001. Factor sensitivity increases with increasing SDFD value.
Figure 2.
Comparisons at each factor activity level of sensitivity for detecting factor deficiencies (SDFD) values among three activators. (A) FII; (B) FV; (C) FVIII; (D) FIX; (E) FX; (F) FXI; (G) FXII. Data are mean ± SD (n = 3 independent experiments). A two-way repeated-measures mixed model with Tukey’s test was used. Only comparisons with significant differences are indicated by connecting lines and asterisks. Significance levels: * p < 0.05, ** p < 0.01. Factor sensitivity increases with increasing SDFD value.
Text Correction
There was an error in the Results section, first paragraph. The corrected text should be:
“In the overall comparison of SDFD, significant differences were found in KL compared with EA and CS (KL vs. EA: mean difference 6.333%, 95% CI 2.748–9.918%; KL vs. CS: 7.824%, 95% CI 1.608–14.04%) (Figure 1C). No significant differences in SDFD among KL, EA, and CS were found at any FX activity level (Figure 2C).”
The authors state that the scientific conclusions are unaffected. This correction was approved by the Academic Editor. The original publication has also been updated.
Reference
- Liang, W.; Xia, M.; Li, J.; Li, F.; Wang, B.; Sun, H. Thromboelastographic Assessment of the Differential Sensitivity of Three Contact Activators to Coagulation Factor Deficiencies in Hemocell Environments. Diagnostics 2026, 16, 3217. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.