Skip to Content
DiagnosticsDiagnostics
  • Article
  • Open Access

18 November 2026

14 Pages

Operational Performance and Turnaround Time of a Tuberculosis Diagnosis Laboratory in Panama

,
,
,
,
,
,
,
,
…
1
Tuberculosis Biomarker Research Unit at División de Una Sola Salud de Instituto de Investigaciones Científicas y Servicios de Alta Tecnología de Panamá–INDICASAT-AIP, Ciudad del Saber, Panama City, Panama
2
Hospital Manuel Amador Guerrero, Caja de Seguro Social, Colón, Panama
3
Programa Regional de Control de Tuberculosis, Ministerio de Salud, Colón, Panama
4
Sistema Nacional de Investigadores SNI-AIP, Ciudad del Saber, Panama City, Panama
Diagnostics2026, 16(22), 3868;https://doi.org/10.3390/diagnostics16223868 
(registering DOI)
This article belongs to the Special Issue Rapid and Precision Diagnostics for Tuberculosis

Abstract

Background: Tuberculosis (TB) diagnosis relies on the coordinated use of rapid molecular testing, microscopy, culture, and drug-resistance assays. This study evaluated laboratory performance and turnaround time (TAT) across an integrated TB diagnostic workflow in Colón Province, Panama, and compared Ziehl–Neelsen (ZN) and auramine–rhodamine microscopy. Methods: A retrospective laboratory-based study included 501 unique patients with positive Xpert MTB/RIF Ultra results between January 2021 and December 2025. The routine workflow included ZN microscopy, Xpert MTB/RIF Ultra, BD BACTEC MGIT 320 culture, and post-culture GenoType MTBDRplus testing. A separate microscopy analysis included 300 specimens with sufficient residual material for paired ZN and auramine–rhodamine staining, using Xpert MTB/RIF Ultra as the reference comparator. Results: ZN microscopy was positive in 96.4% (483/501) of Xpert-positive specimens, and ZN positivity increased significantly across Xpert semiquantitative categories (p for trend < 0.001). Among specimens with final positive MGIT cultures, increasing Xpert semiquantitative category was strongly associated with shorter MGIT TAT (Spearman’s ρ = −0.728, p < 0.001). Initial MGIT contamination occurred in 5.2% (25/480) of cultures; cultures recovered after contamination had a longer median TAT than those without initial contamination (24 vs. 16 days, p < 0.001). Auramine–rhodamine microscopy showed higher sensitivity than ZN microscopy [96.8% (95% CI, 92.8–98.6) vs. 88.0% (95% CI, 82.0–92.2)] and stronger agreement with Xpert [κ = 0.967 (95% CI, 0.938–0.996) vs. 0.874 (95% CI, 0.819–0.928)]. Conclusions: The integrated laboratory workflow supported rapid initial TB diagnosis while maintaining culture and drug-resistance testing capacity. Molecular bacterial burden was associated with smear positivity and culture TAT, while fluorescence microscopy showed improved performance relative to ZN microscopy. Culture recovery procedures preserved diagnostic yield despite delays related to contamination.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.