Abstract
In this exploratory study, we evaluated short-term changes in subjective perceptions and measured physiological indices following three-wavelength LED irradiation of the head. In 36 adults, paraspinal skin surface temperature, subjective relaxation rating on the visual analog scale (VAS), mean heart rate, and RMSSD were measured before intervention, after the 20-min intervention, and approximately 10 min later. The low-configuration batch was enrolled first and the high-configuration batch later, without randomized batch assignment; participants were randomized to the active-light or sham-light condition within each batch. The overall Time effect for skin surface temperature was significant, but adjusted contrasts between each postintervention assessment and baseline were not, and no clear differences in temporal trajectories between light conditions were observed. VAS scores varied over time, with temporal trajectories differing by light condition; however, differences for specific groups or time points remain unconfirmed. Mean heart rate and RMSSD showed no clear changes, with RMSSD residual diagnostics indicating a need for cautious interpretation. Muscle tension, stress, and actual scalp light exposure were not directly measured, precluding conclusions regarding muscle relaxation or therapeutic benefits.
1. Introduction
Occupational and nonoccupational sedentary behavior may be associated with musculoskeletal pain, particularly in the lower back and neck/shoulder regions; however, findings from prospective studies are inconsistent [1]. A study of healthy young women performing computer work showed that visual and psychological stressors were associated with transient increases in trapezius muscle activity and a more forward-leaning sitting posture [2]. Psychological factors, including stress, psychological distress, anxiety, and emotional responses, are also associated with the onset and course of back and neck pain, but only explain part of the observed variation [3]. As these findings do not establish a causal pathway linking sedentary work or posture to persistent upper back muscle tension, developing noninvasive methods to address back muscle tension and stress warrants further investigation.
The anatomical literature describes continuity between the head and neck fascia and the thoracolumbar fascia [4,5], but structural continuity alone does not demonstrate that stimulation of the head is transmitted to and alters distant back muscles. The pathophysiology of myofascial trigger points has not been fully established [6]; therefore, a mechanism linking the head to the back remains hypothetical and requires validation.
Yongtian Head–Sacrum Therapy and polyvagal theory propose possible links between the head and the sacrum or autonomic state [7,8]; however, these remain theoretical frameworks and cannot be regarded as established physiological mechanisms.
Photobiomodulation (PBM) is a noninvasive intervention that uses low-energy red or near-infrared (NIR) laser/LED irradiation. The literature suggests that, following photon absorption by intracellular chromophores, potential targets may include mitochondrial cytochrome c oxidase and photosensitive ion channels, with cellular energy metabolism, redox status, and inflammatory responses modulated through ATP, reactive oxygen species (ROS), nitric oxide (NO), calcium ions, and downstream transcriptional signaling [9,10]. These are possible mechanisms rather than a single, fully established pathway; responses may also depend on cellular or tissue state and irradiation conditions. Reviews of PBM also indicate a possible biphasic dose response: low and higher light doses may elicit different or even opposing biological responses, so effects cannot be assumed to increase linearly with dose [9]. The interpretation of studies must also consider wavelength, power density, energy density, irradiation duration and mode, and irradiation site [9,10,11]; wavelength or LED count alone cannot determine the dose actually absorbed by the target tissue.
Cranial PBM studies have examined cerebral hemodynamics, electroencephalographic signals, and autonomic or peripheral muscle measures [12,13,14,15,16], whereas PBM studies in musculoskeletal pain [17] provide a different application context. Furthermore, potential thermal effects and brain temperature changes during cranial PBM warrant consideration, particularly given that excessive cranial heat exposure can impair motor-cognitive performance [18,19].
However, existing studies vary considerably in terms of wavelength, irradiation site, population, and treatment regimen, and it remains unclear whether a single session of three-wavelength LED irradiation of the head is accompanied by changes in distant physiological measures or subjective perceptions.
Photobiological safety assessments of LED light sources and luminaire systems should follow IEC 62471 and applicable standards [20,21]; test conclusions only apply to the device configurations, distances, and measurement conditions specified in the reports.
A review of multiwavelength PBM indicates that different wavelengths may elicit responses that differ from those elicited by a single wavelength because of differences in tissue absorption [22]; however, this proposition does not establish synergistic effects or clinical advantages for the three-wavelength configuration used in this study. Prior studies of multiple wavelengths, penetration through head tissues, and the irradiation of different tissues vary in scope [11,12,13,22,23,24]. Estimates of penetration through head tissues are also highly heterogeneous and are influenced by factors such as wavelength, light source characteristics, tissue thickness, irradiation site, species, and measurement method [11]. Therefore, values obtained in animals cannot be directly extrapolated to humans or to the device used in this study; existing data also do not establish synergy for the 660/850/1050 nm configuration, the actual amount of light penetrating the human scalp, or the effective dose delivered to target tissues.
Infrared thermography (IRT) measures skin surface temperature, which cannot represent intramuscular temperature or muscle tension; skin temperature, HRV, electrodermal activity, and muscle activity indices obtained at different sites and using different methods are also not interchangeable [25,26,27].
The findings from studies of retinal light exposure and local peripheral irradiation [28,29,30,31,32] cannot be directly extrapolated to remote skeletal muscle effects of head PBM because the light pathways and irradiation sites differ.
This study involves the use of three-wavelength LED irradiation of the head at wavelengths of 660, 850, and 1050 nm as an intervention to explore short-term changes in paraspinal skin surface temperature, subjective relaxation rating on the visual analog scale (VAS), mean heart rate, and RMSSD at T0, T1, and T2. The temperature measure reflects skin surface temperature and is not a direct measurement of muscle temperature or muscle tension. In response to committee recommendations, this study also focuses future research directions on the direct assessment of peripheral hemodynamics and myofascial tension.
2. Materials and Methods
2.1. Study Design and Experimental Procedures
This prospective exploratory study, conducted following ethical approval and photobiological safety testing, evaluated possible associations between noninvasive three-wavelength LED irradiation of the head and the measured physiological and subjective indices. This study was not designed to verify clinical treatment effects; its purpose was to obtain preliminary quantitative data to support hypothesis generation and the planning of future research protocols. Reproducibility was not assessed in this single study.
The following experimental design was used in this study:
- Three-wavelength LED irradiation. Irradiation was applied at prespecified head locations. Paraspinal skin surface temperature and subjective relaxation rating on the visual analog scale (VAS) were recorded using a thermal imaging camera and the VAS, respectively. Mean heart rate and RMSSD were calculated from BVP/PPG signals. Assessments were performed at T0, T1, and T2 (Figure 1 and Figure 2a).Figure 1. Flowchart of the experimental procedure.Figure 2. (a) Measurement of paraspinal skin surface temperature using a thermal imaging camera; (b) cranial positioning markers; and (c) cranial LED irradiation procedure.
- Group allocation and measurement schedule. A total of 36 participants were enrolled: 22 participants in the low-configuration batch were recruited first, followed by 14 participants in the high-configuration batch. Assignment to the low- and high-configuration batches was not randomized. Within each configuration batch, participants were assigned to the active-light condition or the sham-light condition without light at a ratio of 1:1 (11/11 participants in the low-configuration batch and 7/7 participants in the high-configuration batch). Allocation was determined by participants drawing lots according to a random number allocation table prepared in advance by the researchers. Allocation was performed by the first author, who also served as the research assistant; the allocation table was retained by the principal investigator and the authors. Measurements were taken once before the intervention (T0) and twice after the intervention (T1 and T2). The intervention lasted 20 min. All participants followed the same protocol, lasting approximately 60 min: the first 10 min were used for informed consent and changing into medical attire; the preintervention assessment was conducted in a seated position during minutes 10–20; the intervention was administered in a prone position during minutes 20–40; and the postintervention assessments (T1 and T2) were completed in a seated position during minutes 40–60.
- Irradiation configurations. Two output configurations were compared using the same LED module: the low configuration activated four LEDs, whereas the high configuration activated all 18 LEDs. Because the two batches were enrolled sequentially and were not randomly assigned, only associations between configuration batches and study outcomes were explored, with no causal dose comparisons being made.
The study sample included 36 adult participants aged 18–50 years.
The experimental procedure is summarized in Figure 1.
2.1.1. Study Procedure
- Participant recruitment: Participants were recruited through social media and university channels, including announcements in folk therapy groups, referrals from massage practitioners, and patient referrals. A participant screening form (a questionnaire on demographic information and health status) was used to screen potentially eligible individuals. A total of 36 participants were recruited.
- Informed consent and privacy protection during measurements: The study was conducted in the medical school area. In order to use infrared thermography to record paraspinal skin surface temperature, the participants changed into medical gowns in the restroom adjacent to the classroom. The measurement area was screened off; personnel of a different sex were asked to leave during preparation, and a third-party staff member of the same sex was present during measurements to protect participant privacy. The participants were made aware of the informed consent procedures described in Section 2.3 and were instructed to notify the researchers immediately if they experienced discomfort during measurements. After written consent was obtained, names and directly identifying information were replaced with study identification codes. The code-to-identity linkage roster was stored offline in a locked cabinet by the principal investigator.
The ambient temperature in the medical school experimental area was set to 25 ± 2 °C, and relative humidity was set to 45–55%. Before measurement, the participants wore therapy gowns backward and acclimatized to the environment for 10 min; the thermographic measurement location was shielded from direct airflow from air conditioning vents.
- 3.
- Baseline assessment (T0): After group assignment, the participants rested quietly in a seated position for 5 min and then rated their subjective relaxation at T0 using a 0–10-point visual analog scale (VAS). A pilot study of music-assisted relaxation in patients with spinal cord injury carried out by Wood et al. [33] also used a 0–10-point VAS to assess subjective relaxation. In this study, 0 points indicated “not at all relaxed,” and 10 points indicated “completely relaxed.” The VAS is a self-reported subjective outcome, not a physiological measure of muscle relaxation. Researchers used colored markers to mark two paraspinal regions: the upper thoracic region (T3–T7) and the lower thoracic/lumbar region (T12–L1–L2) (Figure 2a). Each region was marked approximately 1 and 5 cm from the spinous processes. After thermal images were acquired, participants rested for 3 min before BVP/HRV recording.
- 4.
- Cranial localization and marking: Before irradiation, a research assistant trained by Yongtian personnel marked the transverse prominence (tender point) approximately 1 cm below the junction of the lambdoid and sagittal sutures. One LED module was placed on each side of the head, with the LED emitters distributed over approximately 2.5 × 4.7 cm (11.75 cm2) on each side. Both modules had the same irradiation area and emitter arrangement. A 20-min intervention was then administered (Figure 2b,c). The participants remained prone during the intervention, and the device was positioned so that they could not see whether it emitted light. They were not informed of their group assignment; thus, the study was participant-blinded. The outcome assessors were not blinded. The active-light and sham-light conditions used the same posture, contact, device position, operation, and intervention duration; the only intended difference was whether light was emitted.
- 5.
- Postintervention assessments (T1 and T2): Immediately after the 20-min irradiation ended, thermal imaging was performed at T1. After 3 min of rest, BVP/HRV was recorded for 5 min, and the VAS was completed. The T2 assessment was then performed using the same procedures approximately 10 min after irradiation ended. After irradiation, the participants returned to and maintained a seated position for the T1 and T2 postintervention assessments.
- 6.
- Data processing and analysis: Raw values for VAS, paraspinal skin surface temperature, RMSSD, and mean heart rate were recorded and analyzed at the prespecified T0, T1, and T2 time points. RMSSD is a time-domain index of heart rate variability, not a direct measure of autonomic function. Thermal images and PPG signals were acquired separately, and each outcome measure was generated according to the procedures. The PLUX HRV Heart Rate Analysis Expansion Module (brand: PLUX; model: OpenSignals HRV Add-on; manufacturer: PLUX Wireless Biosignals, S.A., Lisbon, Portugal; Figure 3) was used with a BVP sensor to acquire PPG signals. The HRV add-on module of OpenSignals® (r)evolution (PLUX Wireless Biosignals, S.A., Lisbon, Portugal) was used to process the BVP signals acquired at a sampling rate of 1000 Hz, to extract the beat-to-beat interval series, and to calculate time-domain, frequency-domain, and nonlinear HRV parameters. The software is distributed by the manufacturer as a continuously updated package and is therefore not identified by a version number. Its algorithm is based on the standards for measurement, physiological interpretation, and clinical use established by the joint Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology (Figure 4).Figure 3. PLUX HRV analysis add-on.Figure 4. OpenSignals® (r)evolution HRV analysis interface (PLUX Wireless Biosignals, S.A., Lisbon, Portugal), showing the BVP signal, the beat-to-beat interval distribution, time-domain HRV parameters, and the power spectral density.
2.1.2. Measurement Instruments
- FLIR T530 thermal imaging camera. Thermal images were acquired using an FLIR T530 thermal imaging camera (FLIR Systems, Inc., Wilsonville, OR, USA) at a fixed distance of 1.3 m (Figure 2a). Mean and maximum skin surface temperatures in the marked paraspinal regions were measured at T0, T1, and T2. The primary Temp analysis used the mean skin surface temperature of the rectangular BX1 region of interest (ROI) in the left upper thoracic T3–T7 paraspinal region, defined by locations approximately 1 cm and 5 cm from the spinous processes. Infrared thermography records the radiative skin surface temperature of the marked paraspinal regions rather than intramuscular temperature; therefore, this outcome is an indirect thermophysiological measure.
- PLUX HRV analysis add-on. The OpenSignals HRV Add-on (PLUX) was used with a PLUX BVP sensor. This module calculates time-domain, frequency-domain, and nonlinear HRV parameters, enabling multidimensional HRV analysis. The finger-clip BVP sensor was connected to a biosignalsplux hub (PLUX Wireless Biosignals, S.A., Lisbon, Portugal) and streamed wirelessly to OpenSignals® (r)evolution.
2.2. Participants and Eligibility Criteria
2.2.1. Baseline Characteristics
A total of 36 adults (19 men and 17 women) were enrolled in the study, with a mean age of 31.08 ± 9.94 years (range: 19–50 years); 27 were employed, and 9 were students. All participants met the screening criteria specified in the study protocol. The students had no affiliation with the research team, and their decision to participate or not did not affect their academic work. The demographic data grouped by low-configuration/high-configuration batch and light condition are presented in Table 1.
Table 1.
Baseline characteristics of participants grouped by low-configuration/high-configuration batch and light condition.
2.2.2. Inclusion Criteria
Participants were required to meet all of the following criteria:
- Adults aged 18–50 years.
- Ability to understand the study information, complete the study procedures, and voluntarily provide written informed consent.
2.2.3. Exclusion Criteria
Participants were excluded if they met any of the following criteria:
- Photosensitivity or allergic reactions to red light, near-infrared light, or other light exposure.
- Head, cervical spine, or spinal surgery within the past 6 months.
- An implanted pacemaker or other electronic medical device.
- A major central or peripheral nervous system disease, or a history of a major neuropsychiatric disorder (e.g., epilepsy, major depressive disorder, panic disorder, Parkinson’s disease, or Alzheimer’s disease).
- Currently receiving chemotherapy.
- Pregnant or breastfeeding.
- Alcohol abuse, drug intoxication, or any other condition deemed by the research team to render the individual unsuitable for study participation.
- Inability to understand the study information or follow study procedures, or refusal to provide written informed consent.
2.3. Research Ethics and Participant Protection
This study was conducted in accordance with the principles of the Declaration of Helsinki and was approved by the Institutional Review Board (IRB) of E-Da Medical Foundation, Kaohsiung, Taiwan, before recruitment began. The original protocol (EMRP-115-055) was approved on 29 May 2026; a subsequent protocol amendment was approved on 18 August 2026. The amendments were as follows:
- LED configuration adjustment: The original protocol initially used the low configuration (four LEDs activated according to the listed unilateral configuration). After 22 participants completed the first phase, an approved amendment added the high configuration (18 LEDs activated according to the listed unilateral configuration) to explore responses under different configurations. The low-configuration and high-configuration batches were enrolled sequentially rather than randomly assigned; therefore, differences between the two batches cannot be regarded as a direct randomized comparison.
- Simplification of experimental procedures: The original procedure included one preintervention measurement and three postintervention measurements; an approved amendment changed this to one preintervention measurement and two postintervention measurements to shorten the procedure and reduce participant burden. Before the amendment to two postintervention measurements, 22 participants had completed the third postintervention measurement. Early observations before the change showed no apparent temperature difference between the third and second postintervention measurements; however, this observation was neither a prespecified formal comparison nor an equivalence test, and therefore cannot support claims that the two time points were identical or that the study results were unaffected. The current measurement time points were as follows: T0, the preintervention baseline; T1, the measurement procedure initiated immediately after completion of the 20 min intervention; and T2, the same measurement procedure initiated approximately 10 min after the start of the T1 measurement procedure. At both postintervention assessments, temperature was first measured using thermal imaging, followed sequentially by 3 min of rest, 5 min of HRV recording, and, finally, a VAS rating. This study can describe only short-term changes through T2 and cannot characterize subsequent temporal trajectories.
- Recruitment and sample size: Before the amendment, the clinical protocol used G*Power (version 3.1.9.7; Heinrich-Heine-Universität Düsseldorf, Germany; F test, ANOVA: repeated measures, within–between interaction) with an effect size of f = 0.25, α = 0.05, power = 0.80, two groups, four measurement points, a correlation among repeated measures of 0.5, and a nonsphericity correction of 1; this yielded a required total sample of 24 participants, with an original recruitment target of 30 participants. Subsequently, under an approved amendment that reduced the number of post-intervention assessments from three to two, the required sample size was re-estimated with the same software (G*Power). Because G*Power does not implement linear mixed models, the calculation was based on the equivalent repeated-measures ANOVA design (within–between interaction) with an effect size of f = 0.25, α = 0.05, power = 0.80, two measurement points (baseline and post-intervention, corresponding to the two planned contrasts of T1–T0 and T2–T0 specified in the linear mixed models), a correlation among repeated measures of 0.5, and a nonsphericity correction of 1. This simplification is conservative relative to the three time points analysed, because fewer repeated measurements require a larger sample. The calculation yielded a required total sample of 42 participants; after allowing for extreme values and dropout, the amended protocol planned to recruit 60 participants, that is, 30 per light condition across the two configuration batches. Recruitment stopped after 36 participants had been enrolled because of recruitment difficulties; 36 participants was not a prespecified stopping point. Actual enrollment was below the planned recruitment target, and the amount of valid data differed across outcomes, potentially limiting statistical power, particularly for interactions. Therefore, it is not claimed that 36 participants provided adequate statistical power in this study, and the results remain exploratory; a nonsignificant result does not indicate the absence of an effect.
The statistical analysis plan was changed from the originally planned ANOVA or t-tests to a linear mixed-effects model. For all four outcomes, the raw measurements at T0, T1, and T2 were used as dependent variables.
T0 was the preintervention baseline; T1 was the measurement procedure initiated immediately after completion of the 20 min intervention; and T2 was the second procedure, initiated approximately 10 min after the start of the T1 measurement procedure.
The RI + ID main model specified a subject-level random intercept for Subject_ID (variance components, VC) and an identity residual covariance structure for within-subject repeated measurements; fixed effects included Light, Dose, Time, and all two-way and three-way interactions. Candidate CS, AR(1), and UN models were also compared as sensitivity checks. These models did not specify a random intercept and were therefore alternative overall marginal models without random intercepts, distinct from the RI + ID main model; they cannot be described as retaining the random intercept while changing only the residual structure. Models were estimated using REML, with Satterthwaite denominator degrees of freedom and Type III tests of fixed effects, and 95% confidence intervals were reported. Each outcome was analyzed using its own valid raw data, without pooling data or using a common sample size across outcomes.
2.3.1. Recruitment and Informed Consent Procedures
Participants were recruited through community channels. The research team enrolled participants at I-Shou University College of Medicine and provided oral and written explanations of the study procedures, risks, and anticipated benefits. After written informed consent was obtained, light condition was randomized within each configuration batch at a 1:1 ratio. Research staff implemented allocation using a pre-generated random-number lookup table, with participants drawing lots to determine assignment to the active-light condition or the sham-light condition with no light. Of the 36 participants, 22 were in the low-configuration batch (11 in the active-light condition and 11 in the sham-light condition with no light), and 14 were in the high-configuration batch (7 in the active-light condition and 7 in the sham-light condition with no light). The low-configuration batch was enrolled first, followed by the high-configuration batch. None of the 9 students were affiliated with the research team, and their decision to participate did not affect their academic grades. The participants could withdraw at any time without affecting their rights or access to care.
2.3.2. Confidentiality and Privacy Protection
The confidentiality and privacy of participant data were protected throughout the study, and access to study data was restricted to research team members. The data used for analysis were de-identified and managed using study identification codes; the list linking these codes to participant identities was stored separately offline in a locked cabinet in the principal investigator’s office. The study results were presented in aggregate form.
2.4. Intervention Device and Irradiation Parameters
Intervention device: three-wavelength LED module. The device was a custom-built low-energy LED module emitting at wavelengths of 660, 850, and 1050 nm. Its optical and electrical design and its component specifications were defined by the authors, and the module was fabricated to specification by MORE WEII ELECTRONIC CORP. (Kaohsiung, Taiwan); the device is not commercially available. It was designed as a photobiomodulation tool for research rather than for disease diagnosis or treatment. Accordingly, the study protocol classified it as an experimental tool rather than a Class II or Class III medical device requiring certification by Taiwan’s Ministry of Health and Welfare (Figure 5).
Figure 5.
Three-wavelength LED module: (a) front view (LED array); (b) back view (driver circuit).
The photobiological safety of the complete high-output LED configuration (two devices, one on each side of the head, each containing 18 LEDs; each device configured as 660 nm × 6, 850 nm × 3, and 1050 nm × 9) was tested by a TAF-accredited laboratory and passed the requirements of CNS 15592/IEC 62471:2006 [20,21] (Test Report No. 25-1015-01). The complete bilateral configuration tested was classified as Exempt (no risk) at the 200 mm test distance specified in the report. This classification describes the tested device and test geometry; it does not constitute a direct measurement of irradiance or radiant exposure at the treatment plane approximately 1–2 mm from the scalp. The device was used as a tool for academic research and physiological observation, not for disease diagnosis or treatment.
The LED modules were positioned over the predefined bilateral Co3 regions, with one module on each side and identical irradiation areas and LED configurations. The LEDs in each module were distributed over an area of 2.5 × 4.7 cm (11.75 cm2). The rubber contact plane was positioned close to the scalp, with the emitting LEDs approximately 1–2 mm from the scalp. The LEDs were embedded in holes drilled in the rubber; the LED package outer diameter was approximately 0.5 cm, and the specified viewing angle was 30°. Manual drilling resulted in slight variations in the distance between the emitting surface and the rubber contact plane; 1–2 mm represents an approximate configuration value rather than individual LED measurements. Power and safety estimates used the higher-output measurement set (set B): the mean output per LED was 11.627 mW for the 660 nm red LEDs, 12.030 mW for the 850 nm LEDs, and 8.848 mW for the 1050 nm LEDs. The power worksheet labeled the red light column as 650 nm; the actual red light wavelength was 660 nm. This manuscript reports the actual wavelength and treats 650 nm as a worksheet label. These values are light-source output readings under the specified measurement settings, not direct measurements at the scalp treatment plane.
The drive current for each LED was 20 mA, with forward voltages of approximately 2.1 V for 660 nm and 1.5 V each for 850 and 1050 nm. Based on the listed unilateral configurations, the electrical input for the low-configuration module containing 2/1/1 LEDs was approximately 144 mW, with approximately 172.8 J of electrical energy over 20 min; the high-configuration module containing 6/3/9 LEDs had an electrical input of approximately 612 mW, with approximately 734.4 J over 20 min. These values are estimates of electrical input for a unilateral module and are not equivalent to optical output or energy absorbed by the scalp; they were not doubled to obtain bilateral totals. Based on the higher-output measurements from set B, the total light-source output of the unilateral low-configuration module was approximately 44.132 mW, with approximately 52.958 J of optical energy over 20 min; the unilateral high-configuration module had an output of approximately 185.478 mW, with approximately 222.574 J of optical energy over 20 min. Total optical power was the sum of the outputs of all LEDs, and optical energy was calculated as total optical output power × 1200 s; it was not concentrated in a single LED. These values are reported for the listed unilateral configurations without extrapolation to bilateral totals, and do not represent the dose absorbed by the scalp or directly measured J/cm2. Assuming uniform distribution of optical output over the unilateral geometric area of 11.75 cm2, the conditional mean irradiance was approximately 3.756 mW/cm2 for the low configuration and 15.785 mW/cm2 for the high configuration; the conditional mean radiant exposures over 20 min were approximately 4.507 and 18.942 J/cm2, respectively. These are geometric average estimates rather than measurements at the scalp plane and do not account for hole positions, differences in distance, light-spot overlap, or spatial nonuniformity.
The LEDs were approximately 1–2 mm from the scalp, but the effective emitting aperture, wavelength-specific irradiance, beam distribution, and J/cm2 were not directly measured at this treatment plane. Therefore, the Exempt classification at the 200 mm test distance only applies to the complete configuration and measurement distance conditions specified in the report described above and does not indicate that direct measurements were performed at 1–2 mm. This clarification does not negate the device’s successful testing under CNS 15592/IEC 62471:2006.
2.5. Irradiation Sites and Three-Wavelength Intervention Procedure
2.5.1. Operational Definitions of the Co3 and Co5 Regions
Before irradiation, Co5 was located at the junction of the lambdoid and sagittal sutures. Co3 was marked at a transverse prominence (tender point) approximately 1 cm anteroinferior to Co5. On each side of the head, the irradiation region was aligned with Co3 and extended toward the forehead, measuring approximately 2 cm in length and 4.5 cm in width. These Co3 and Co5 locations served as protocol-specific operational landmarks, with their placement informed by the craniosacral framework attributed to Cheng C.-L. [7]; their precise locations were defined for this study and were not regarded as recognized anatomical structures or established acupuncture points on the head.
Before each intervention, the same researcher sequentially located Co5 and Co3 using standardized palpation to maintain consistent placement of the module contact planes. As described in Section 2.4, the two LED modules were positioned over the predefined bilateral Co3 regions, with the LED emitters approximately 1–2 mm from the scalp and embedded in drilled holes in the rubber. Because the holes were drilled manually, the actual distances between the emitting surfaces and the rubber contact plane varied slightly and were not measured for each emitter.
2.5.2. Monitoring and Precautions During Irradiation
To ensure data quality, the participants were instructed not to use mobile phones during each 5-min HRV recording at T0, T1, and T2; to rest both hands flat on the high stool; and to keep the finger clip as still as possible.
2.5.3. Safety Monitoring and Emergency Procedures
The researchers observed the participants’ responses throughout the procedure. If discomfort occurred, irradiation was stopped immediately, and rest, continued observation, or referral for medical care was arranged as appropriate and documented on the adverse event form. After T2, 26 participants (18 in the active-light condition and 8 in the sham-light condition without light emission) were also contacted by telephone or LINE; all of those contacted reported no adverse reactions after returning home. This finding reflects only the short-term follow-up of a limited number of participants and does not establish long-term safety.
2.6. Outcome Measures and Data Sources
Primary and secondary outcome measures were prespecified before the study began. Laboratory assessments were conducted at 3 scheduled time points: immediately before the first irradiation (T0); immediately after completion of the 20 min intervention, when the T1 measurement protocol began in a seated position, with thermal imaging performed first, followed by 3 min of rest, 5 min of HRV recording, and, finally, the VAS assessment; and T2, which began in a seated position approximately 10 min after the start of the T1 measurement protocol and followed the same sequence of thermal imaging, 3 min of rest, 5 min of HRV recording, and VAS assessment.
The primary outcome measures included raw values of mean paraspinal skin surface temperature in the left upper thoracic T3–T7 BX1 region measured using infrared thermal imaging, as well as raw RMSSD and mean heart rate values. Temp was obtained from the BX1 rectangular ROI, whose boundaries were defined at approximately 1 cm and 5 cm from the spinous processes. All three measures were assessed at T0, T1, and T2.
The secondary and exploratory outcome measure was the raw subjective relaxation rating on the visual analog scale (VAS) at T0, T1, and T2. The VAS is a self-reported outcome, not a direct physiological measure of muscle relaxation.
2.7. Statistical Analysis
2.7.1. Data Cleaning and Descriptive Statistics
The primary analyses used the raw measured values of the four outcomes at T0, T1, and T2 as dependent variables. Each outcome was included separately according to its own data quality and missing data rules, without shared screening criteria. The numbers of participants with valid data were 36 for Temp, 36 for VAS, 36 for mean heart rate, and 35 for RMSSD. The numbers of participants with valid observations at each time point are provided in the notes to the corresponding tables.
HRV data were inspected in Kubios HRV Scientific Lite (version 4.3.0; Kubios Oy, Kuopio, Finland) and, where required, artefact-corrected there; the corrected RR series were used for the HRV parameters calculated in OpenSignals® (r)evolution, and the derived parameters were analysed in IBM SPSS Statistics (version 27.0; IBM Corp., Armonk, NY, USA). Each measure was included according to prespecified data quality criteria; an extreme-value flag indicated only that the data required review, not that a measurement error had been confirmed. Descriptive statistics are presented as means, and inferential statistics used two-tailed tests at the conventional 5% significance level.
The numbers of participants with valid data differed across measures and time points. Each measure was analyzed using its own valid data, without substituting participant counts from other measures.
Descriptive statistics were used to summarize participant age, height, weight, and other baseline characteristics. The baseline data are presented in Table 1, and the observed means and numbers of participants with valid data at each time point are presented in the corresponding tables.
2.7.2. Linear Mixed-Effects Model (LMM)
The four raw measures were analyzed separately using linear mixed-effects models to account for repeated measurements at T0, T1, and T2 within each participant. The models included light condition, configuration batch (Dose factor), time, and all their interactions. The RI + ID main model included a subject-level random intercept and an identity residual covariance structure for within-subject repeated measurements. Models were estimated using REML, and the principal fixed effects were presented using Type III tests and 95% confidence intervals. All statistical models were fitted with IBM SPSS Statistics for Windows (version 27.0) using the MIXED procedure. Two contrasts, T1–T0 and T2–T0, were also calculated from model-estimated marginal means with Bonferroni adjustment; estimated differences, 95% confidence intervals, and adjusted p-values were reported. Contrast-specific standardized effect sizes were expressed as partial η2, calculated from the t-statistic and Satterthwaite denominator degrees of freedom for each contrast; 0.01, 0.06, and 0.14 served as approximate statistical benchmarks for small, medium, and large effects, respectively, and did not indicate clinical importance. The two time contrasts represented model-averaged changes across light conditions and configuration batch levels (Dose factor); differences in temporal patterns between light groups were evaluated using the Light × Time interaction.
Sensitivity checks were also performed using CS, AR(1), and UN repeated-measures covariance structures. These candidate models did not specify a random intercept and were therefore interpreted as overall marginal alternative models without a random intercept. Primary inference remained based on the prespecified RI + ID main model, which was not replaced on the basis of a single model ranking.
Model assumptions were assessed using residual plots and normality checks. Temp and VAS showed no clear warning signs of departures from normality; mean heart rate showed tail deviations and a few extreme values, whereas RMSSD showed more pronounced tail deviations and greater residual dispersion immediately after the intervention. Mean heart rate and RMSSD results should be interpreted cautiously.
The results were interpreted with consideration of both statistical significance and effect size. Effect sizes describe the magnitude of differences and are approximately classified as small, medium, or large, but do not indicate clinical importance. Model-adjusted estimates and raw observed means serve different purposes and are presented separately in this manuscript.
The model primarily examined three questions: whether the outcome measures changed over time, whether temporal changes differed between the active-light and sham-light conditions, and whether temporal changes differed between the low-configuration and high-configuration batches. Because the low-configuration and high-configuration batches were enrolled sequentially and were not randomly assigned, differences between configuration batches were interpreted solely as exploratory findings.
3. Results
In terms of safety and tolerability, none of the 36 participants reported adverse reactions during the experiment. None of the participants contacted by telephone or LINE after T2 (18 in the active-light condition and eight in the sham-light condition) reported any adverse reactions after returning home; these follow-up findings only cover the participants contacted, and short-term observation and cannot be used to infer long-term safety for all participants.
With regard to baseline characteristics, the overall demographic characteristics of the 36 participants are presented in Table 1, including age, sex, height, weight, and BMI by low-configuration/high-configuration batch and light condition. The low-configuration batch of 22 participants was enrolled first, followed by the high-configuration batch of 14 participants. Because the two batches coincided with the enrollment sequence, batch confounding may be present.
Summary of the Main Results for the Four Outcomes. In addition to the RI + ID main model, other repeated-measures models were compared as sensitivity checks. Model rankings differed across outcomes; therefore, the primary analysis continued to use the prespecified RI + ID main model rather than basing conclusions on a single model ranking.
The overall Time effect for paraspinal skin surface temperature was significant, with a large effect size; differences in temporal changes between the low-configuration and high-configuration batches were also significant, with a medium effect size (Table 2). The corresponding T1–T0 and T2–T0 contrasts are reported in Table 3. The overall observed mean was slightly higher at T1 and declined at T2 (Table 4). Figure 6 presents the raw observed means for the low-configuration and high-configuration batches, pooling the active-light and sham-light conditions. Because the two batches were enrolled sequentially and coincided with enrollment order, neither the batch differences in the figure nor the model interactions can be interpreted as causal dose effects. After Bonferroni adjustment, neither the T1 nor the T2 model contrast relative to T0 was significant (Table 3). Light × Time was also nonsignificant, although its effect size was medium (Table 2). All remaining fixed effects for Temp were nonsignificant and had smaller effect sizes (Table 2). Thus, this study provided no evidence of a temperature increase specific to active-light irradiation.
Table 2.
Summary of Type III fixed effects from the RI + ID main model for the four outcomes based on raw measurements (three effects each for Temp and VAS; two representative effects each for mean heart rate and RMSSD).
Table 3.
RI + ID main model-estimated contrasts of T1 and T2 relative to T0 for the four outcomes.
Table 4.
Raw observed means of the four outcomes at the three measurement time points.
Figure 6.
Left upper thoracic T3–T7 paraspinal mean skin surface temperature in the BX1 region at T0, T1, and T2, presented as raw observed means for the low-configuration batch (enrolled first) and high-configuration batch (enrolled later), pooling the active-light and sham-light conditions. BX1 is the ROI code for mean left upper thoracic T3–T7 paraspinal temperature in this study; its rectangular ROI was defined by boundaries approximately 1 cm and 5 cm from the spinous processes. Error bars indicate descriptive 95% confidence intervals; values are raw observed means, not model-adjusted estimates.
Both the overall Time effect and the Light × Time interaction for VAS were significant, with large effect sizes (Table 2), indicating that VAS changed over time and that its temporal trajectory differed by light condition. The model contrasts for T1 and T2 relative to T0 listed in Table 3 represent average changes across light conditions and configuration-batch levels (Dose factor) and cannot be directly attributed to active-light irradiation. Figure 7 presents the raw observed means and descriptive 95% confidence intervals for the four groups defined by low-configuration/high-configuration batch and active-light/sham-light condition; the error bars do not represent within-group significance tests. The Light × Dose effect had a medium effect size but was nonsignificant; the other fixed effects were also nonsignificant and had smaller effect sizes (Table 2). The configuration-batch-averaged contrasts reported below quantify differences in change between light conditions but do not establish configuration-batch-specific effects or separate contrasts for each of the four configuration-batch-by-light groups at each individual time point. VAS reflects self-reported perceptions and is not a direct measure of muscle relaxation or treatment efficacy.
Figure 7.
Raw observed mean VAS scores at T0, T1, and T2, grouped by low-configuration/high-configuration batch and active-light/sham-light condition. Error bars indicate descriptive within-group 95% confidence intervals.
To quantify the between-condition differences in change underlying the Light × Time interaction, we estimated configuration-batch-averaged active-minus-sham contrasts from the full RI + ID primary model using direct linear contrasts with equal weighting across the two configuration-batch levels represented by Dose_Code. The estimated difference in change was 0.781 VAS points for T1–T0 (SE = 0.325, df = 62.7; Bonferroni-adjusted family-wise 95% CI [0.033, 1.530], adjusted p = 0.0388) and 1.159 VAS points for T2–T0 (SE = 0.328, df = 62.9; family-wise 95% CI [0.407, 1.910], adjusted p = 0.0015). These positive contrasts indicate a greater increase in self-reported relaxation scores under active light than under sham light, averaged equally across the two configuration batches.
RMSSD showed no clear overall temporal or light-related differences, and most effect sizes were small. The Bonferroni-adjusted model contrasts for T1 and T2 relative to T0 were also nonsignificant (Table 3). The model estimate immediately after the intervention was higher in the low-configuration batch, but this difference was not statistically significant and remains an exploratory observation requiring verification. The effect sizes for Dose × Time, Light × Time, and Time were relatively larger, but none was significant; the remaining fixed effects were also nonsignificant and had smaller effect sizes (Table 2). The residual distribution showed tail deviations, dispersion was greater at T1, and fewer valid postintervention observations were available. These results therefore require cautious interpretation and cannot establish autonomic improvement.
Mean heart rate showed no clear overall temporal or light-related differences, and effect sizes were small. The Bonferroni-adjusted model contrasts for T1 and T2 relative to T0 were also nonsignificant (Table 3). Light, Light × Dose × Time, and Time were the three fixed effects with relatively larger effect sizes, but none was significant; the remaining fixed effects were also nonsignificant and had smaller effect sizes (Table 2). Residual checks revealed tail deviations and a few extreme signals. The current results are not sufficient to either demonstrate improvement or establish the complete absence of an effect.
The lines in Figure 6 show the raw observed means for the low-configuration and high-configuration batches, pooling the active-light and sham-light conditions; error bars indicate descriptive 95% confidence intervals (CIs), not model-adjusted estimated marginal means (EMMs). The low-configuration and high-configuration batches were enrolled sequentially, and the differences shown do not represent causal dose effects. Fixed effects for Temp are presented in Table 2, and adjusted model contrasts for T1 and T2 relative to T0 are presented in Table 3.
Figure 7 presents raw observed mean VAS scores for the four groups defined by low-configuration/high-configuration batch × light condition; error bars indicate descriptive within-group 95% confidence intervals (CIs), not within-group significance tests. The Light × Time interaction is reported in Table 2; the figure does not establish a light effect in any specific subgroup or at any specific time point.
4. Discussion
The overall Time effect on paraspinal skin surface temperature was significant, but neither the T1-versus-T0 nor the T2-versus-T0 comparison was significant after Bonferroni adjustment, and the Light × Time interaction was also not significant. Therefore, these results do not support an inference of warming specific to the active-light condition. The low-configuration and high-configuration batches were enrolled sequentially; differences between them may also reflect batch or enrollment timing factors and should not be interpreted as dose effects. Furthermore, thermal imaging measures skin surface temperature, not muscle temperature or muscle tension.
Among cranial PBM studies more closely related to the present study, Shahdadian et al. [13] and Wang et al. [14] reported changes in cerebral hemodynamics or electroencephalographic signals, whereas Pinto et al. [15] investigated heart rate variability and thigh electromyography during PBM combined with cardiopulmonary rehabilitation. These studies differed in their populations, interventions, and measurement endpoints, and none measured paraspinal skin surface temperature or subjective relaxation as assessed in the present study. They therefore provide background alone and cannot directly explain the present findings.
Studies of retinal light exposure and local irradiation of the hands, feet, or upper arms have reported thermoregulatory, microcirculatory, or skin temperature responses [28,29,30,31,32]. However, their light pathways, irradiation sites, and measurement endpoints differed from those in the present study, and they do not support an inference that cranial PBM causes warming of distant skeletal muscles. Peripheral blood flow and related mediators were not directly measured in this study; therefore, no inferences can be made regarding vascular mechanisms such as nitric oxide.
The cranial LED placement in this study was guided by Yongtian Head–Sacrum Therapy and the “parent–spine biomechanics” proposed by Cheng [7,34]; however, these theories remain to be validated. Myofascial trigger points and tension transmission from the head to the spine were not directly measured in this study and thus no direct evidence supporting a craniosacral biomechanical mechanism can be provided. This hypothesis is also not used to explain the temperature or VAS results.
The VAS scores changed over time and their temporal trajectories differed by light condition, representing a relatively clear subjective finding in this study. However, configuration-batch-averaged active-minus-sham contrasts from the full primary model indicated a greater increase in self-reported relaxation scores under active light than under sham at T1 and T2. Configuration-batch-specific or individual-group effects were not established. The music-assisted relaxation study by Wood et al. [33] also used a subjective VAS, but its intervention and population differed. It provides background on the scale only and cannot establish the effectiveness of PBM. Because higher VAS scores indicated greater self-reported relaxation (0 = “not at all relaxed”; 10 = “completely relaxed”), the positive contrasts reflect a greater increase in subjective ratings, not direct measurements of muscle relaxation. mean heart rate and RMSSD also showed no clear differences related to light condition. Therefore, changes in subjective ratings cannot establish reduced muscle tension or improved autonomic function.
Because the two configuration batches were enrolled sequentially rather than randomized, the configuration-batch-averaged contrast should not be interpreted as a causal dose effect. The nonsignificant Light × Time × Dose_Code interaction should not be interpreted as evidence of equivalence between the two configuration batches.
Neither mean heart rate nor RMSSD showed clear time- or light-related differences, and the estimated effect sizes were small. These findings do not establish that either measure was entirely unresponsive, but the current data are insufficient to support improved autonomic function. In particular, the RMSSD residual distribution showed deviations in the tails, and the dispersion across time points was not ideal. Further confirmation using more complete data and appropriate models is needed.
This study only included 36 participants, and the low-configuration batch was enrolled first; thus, the results may have been influenced by batch-related factors. The participants were single-blinded and the outcome assessors were not blinded. Measurements at T0, T1, and T2 were all obtained in the seated position, whereas the intervention was administered in the prone position. Because the study did not include a rest-only or posture control, not all shared changes can be attributed to light irradiation. The third postintervention measurement was removed based on an approved amendment and early observations; however, no formal equivalence test was conducted, so changes at later time points cannot be inferred. The actual distribution of light exposure and temperature increase at the scalp were not directly measured. The absence of clear adverse reactions in the short term does not establish long-term safety.
5. Conclusions
Different results were found for the four outcomes. Although paraspinal skin surface temperature showed an overall Time effect and temporal variation across configuration batches, neither of the two adjusted time contrasts nor the Light × Time interaction was significant, providing no evidence of a temperature increase specific to the active-light condition. The temporal trajectory of the subjective relaxation rating on the visual analog scale differed by light condition, but a light effect in a specific group or at a specific time point has not yet been established. Mean heart rate and RMSSD showed no clear changes. Statistical effect sizes do not equate to clinical benefits, and nonsignificant results do not establish the absence of an effect. This study cannot demonstrate that three-wavelength LED irradiation directly promotes muscle relaxation or improves autonomic function.
The recruitment, intervention, and measurement procedures documented in this study may provide practical insights for planning future research.
Author Contributions
Conceptualization, Y.-S.W. and C.-L.C.; methodology, C.-Y.W.; software, C.-Y.W.; validation, C.-Y.L., C.-Y.W., and K.-N.H.; formal analysis, C.-L.C.; investigation, Y.-S.W.; resources, C.-L.C. and K.-N.H.; data curation, Y.-S.W.; writing—original draft preparation, Y.-S.W.; writing—review and editing, C.-Y.L., C.-Y.W., and K.-N.H.; visualization, Y.-S.W.; supervision, C.-Y.L., C.-Y.W., and K.-N.H. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
This study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board (IRB) of E-Da Medical Foundation, Kaohsiung, Taiwan (approval number EMRP-115-055; the original protocol was approved on 29 May 2026, and the protocol amendment was approved on 18 August 2026).
Informed Consent Statement
Written informed consent was obtained from all participants in this study. Consent for publication: Not applicable.
Data Availability Statement
The data presented in this study are available from the corresponding authors upon reasonable request.
Acknowledgments
The authors would like to thank the Yongtian Craniosacral Research Laboratory for technical support. During the preparation of this manuscript, the authors used Google Translate for language editing and academic writing assistance. The authors have reviewed and edited the output and take full responsibility for the content of this publication.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| BVP | Blood volume pulse |
| CI | Confidence interval |
| CNS | National Standards of the Republic of China (CNS) |
| CS | Compound symmetry |
| EMMs | Estimated marginal means |
| HRV | Heart rate variability |
| ID | Identity (within-subject repeated residual structure) |
| IEC | International Electrotechnical Commission |
| IQR | Interquartile range |
| IRB | Institutional Review Board |
| LED | Light-emitting diode |
| LMM | Linear mixed-effects model |
| NIR | Near-infrared |
| PBM | Photobiomodulation |
| PPG | Photoplethysmography |
| REML | Restricted maximum likelihood |
| RMSSD | Root mean square of successive differences between normal-to-normal intervals |
| SD | Standard deviation |
| SPSS | Statistical Package for the Social Sciences |
| T0 | Baseline measurement |
| T1 | Measurement procedure beginning immediately after the 20 min intervention ended (thermal imaging performed first) |
| T2 | Second measurement procedure initiated approximately 10 min after the start of the T1 measurement procedure |
| VAS | Visual analog scale |
| AVG IHR | Mean heart rate |
| ipRGC | Intrinsically photosensitive retinal ganglion cells |
| IRT | Infrared thermal imaging; noncontact estimation of skin surface temperature |
| NO | Nitric oxide |
| tPBM | Transcranial photobiomodulation |
| 1H-MRS | Proton magnetic resonance spectroscopy |
| AICc | Small-sample corrected Akaike information criterion |
| BIC | Bayesian Information Criterion |
| GLS | Generalized least squares |
| Nlme | R package for linear and nonlinear mixed-effects models |
| UN | Unstructured covariance structure |
References
- Dzakpasu, F.Q.S.; Carver, A.; Brakenridge, C.J.; Cicuttini, F.; Urquhart, D.M.; Owen, N.; Dunstan, D.W. Musculoskeletal pain and sedentary behaviour in occupational and non-occupational settings: A systematic review with meta-analysis. Int. J. Behav. Nutr. Phys. Act. 2021, 18, 159. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mork, R.; Falkenberg, H.K.; Fostervold, K.I.; Thorud, H.M.S. Visual and psychological stress during computer work in healthy, young females—Physiological responses. Int. Arch. Occup. Environ. Health 2018, 91, 811–830. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Linton, S.J. A review of psychological risk factors in back and neck pain. Spine 2000, 25, 1148–1156. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Prabu Raja, G.; Shyamasunder Bhat, N.; Marie Cruz, A.; Prabhu, A.; Fernandes, S.; Naaz, N. The anatomical myofascial continuum between the neck and eyes. Clin. Anat. 2022, 35, 340–346. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Willard, F.H.; Vleeming, A.; Schuenke, M.D.; Danneels, L.; Schleip, R. The thoracolumbar fascia: Anatomy, function and clinical considerations. J. Anat. 2012, 221, 507–536. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shah, J.P.; Thaker, N.; Heimur, J.; Aredo, J.V.; Sikdar, S.; Gerber, L. Myofascial trigger points then and now: A historical and scientific perspective. PM R 2015, 7, 746–761. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cheng, Chih-Lung. Craniosacral Therapy: Skull Volume (頭薦療法—頭骨篇); Yongtian Medical Research Institute: Tainan, Taiwan, 2020. [Google Scholar]
- Porges, S.W. The polyvagal perspective. Biol. Psychol. 2007, 74, 116–143. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hamblin, M.R. Mechanisms and applications of the anti-inflammatory effects of photobiomodulation. AIMS Biophys. 2017, 4, 337–361. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- de Freitas, L.F.; Hamblin, M.R. Proposed mechanisms of photobiomodulation or low-level light therapy. IEEE J. Sel. Top. Quantum Electron. 2016, 22, 7000417. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Salehpour, F.; Cassano, P.; Rouhi, N.; Hamblin, M.R.; De Taboada, L.; Farajdokht, F.; Mahmoudi, J. Penetration profiles of visible and near-infrared lasers and light-emitting diode light through the head tissues in animal and human species: A review of literature. Photobiomodul. Photomed. Laser Surg. 2019, 37, 581–595. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hamblin, M.R. Shining light on the head: Photobiomodulation for brain disorders. BBA Clin. 2016, 6, 113–124. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shahdadian, S.; Wang, X.; Kang, G.; Carter, C.; Liu, H. Site-specific effects of 800- and 850-nm forehead transcranial photobiomodulation on prefrontal bilateral connectivity and unilateral coupling in young adults. Neurophotonics 2023, 10, 025012. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, X.; Wanniarachchi, H.; Wu, A.; Gonzalez-Lima, F.; Liu, H. Transcranial photobiomodulation and thermal stimulation induce distinct topographies of EEG alpha and beta power changes in healthy humans. Sci. Rep. 2021, 11, 18917. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pinto, A.P.; Lemos, S.L.; Fagundes, A.A.; Das Neves, M.F.; Lopes-Martins, R.Á.B.; Lima, F.P.S.; Lima, M.O. Transcranial photobiomodulation therapy associated with cardiorespiratory rehabilitation in spastic subjects. Lasers Med. Sci. 2023, 38, 249. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gullett, N.; Zajkowska, Z.; Walsh, A.; Harper, R.; Mondelli, V. Heart rate variability (HRV) as a way to understand associations between the autonomic nervous system (ANS) and affective states: A critical review of the literature. Int. J. Psychophysiol. 2023, 192, 35–42. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cotler, H.B.; Chow, R.T.; Hamblin, M.R.; Carroll, J. The Use of Low Level Laser Therapy (LLLT) for Musculoskeletal Pain. MOJ Orthop. Rheumatol. 2015, 2, 00068. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Weerasekera, A.; Coelho, D.R.A.; Ratai, E.-M.; Collins, K.A.; Hurtado Puerto, A.M.; De Taboada, L.; Gersten, M.B.; Clancy, J.A.; Hoptman, M.J.; Irvin, M.K.; et al. Dose-dependent effects of transcranial photobiomodulation on brain temperature in patients with major depressive disorder: A spectroscopy study. Lasers Med. Sci. 2024, 39, 249. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Piil, J.F.; Christiansen, L.; Morris, N.B.; Mikkelsen, C.J.; Ioannou, L.G.; Flouris, A.D.; Lundbye-Jensen, J.; Nybo, L. Direct exposure of the head to solar heat radiation impairs motor-cognitive performance. Sci. Rep. 2020, 10, 7812. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- IEC 62471:2006; Photobiological Safety of Lamps and Lamp Systems. International Electrotechnical Commission: Geneva, Switzerland, 2006.
- CNS 15592:2012; 光源及光源系統之光生物安全性 [Photobiological Safety of Lamps and Lamp Systems]. Bureau of Standards, Metrology and Inspection (BSMI), Ministry of Economic Affairs: Taipei, Taiwan, 2012.
- Lima, A.M.C.T.; da Silva Sergio, L.P.; de Souza da Fonseca, A. Photobiomodulation via multiple-wavelength radiations. Lasers Med. Sci. 2020, 35, 307–316. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- de Sá, C.M.D. Effect of 660/850 nm LED on the microcirculation of the foot: Neurovascular biphasic reflex. Lasers Med. Sci. 2021, 36, 1883–1889. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Blokina, I.; Iluykov, E.; Myagkov, D.; Tuktarov, D.; Popov, S.; Inozemzev, T.; Fedosov, I.; Shirokov, A.; Terskov, A.; Dmitrenko, A.; et al. Photobiomodulation under electroencephalographic controls of sleep for stimulation of lymphatic removal of toxins from mouse brain. J. Vis. Exp. 2024, 208, 67035. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gioia, F.; Nardelli, M.; Scilingo, E.P.; Greco, A. Autonomic Regulation of Facial Temperature during Stress: A Cross-Mapping Analysis. Sensors 2023, 23, 6403. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Perpetuini, D.; Formenti, D.; Cardone, D.; Trecroci, A.; Rossi, A.; Di Credico, A.; Merati, G.; Alberti, G.; Di Baldassarre, A.; Merla, A. Can Data-Driven Supervised Machine Learning Approaches Applied to Infrared Thermal Imaging Data Estimate Muscular Activity and Fatigue? Sensors 2023, 23, 832. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ruchkin, V.; Koposov, R.A. Touch, temperature, and relief: A multilevel integrative model of hedonic regulation in massage and thermal therapies. Front. Physiol. 2026, 17, 1888366. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rupp, A.C.; Ren, M.; Altimus, C.M.; Fernandez, D.C.; Richardson, M.; Turek, F.; Hattar, S.; Schmidt, T.M. Distinct ipRGC subpopulations mediate light’s acute and circadian effects on body temperature and sleep. eLife 2019, 8, e44358. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cajochen, C.; Münch, M.; Kobialka, S.; Kräuchi, K.; Steiner, R.; Oelhafen, P.; Orgül, S.; Wirz-Justice, A. High sensitivity of human melatonin, alertness, thermoregulation, and heart rate to short wavelength light. J. Clin. Endocrinol. Metab. 2005, 90, 1311–1316. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Samoilova, K.A.; Zhevago, N.A.; Petrishchev, N.N.; Zimin, A.A. Role of nitric oxide in the visible light-induced rapid increase of human skin microcirculation at the local and systemic levels: II. healthy volunteers. Photomed. Laser Surg. 2008, 26, 443–449. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schindl, A.; Heinze, G.; Schindl, M.; Pernerstorfer-Schön, H.; Schindl, L. Systemic effects of low-intensity laser irradiation on skin microcirculation in patients with diabetic microangiopathy. Microvasc. Res. 2002, 64, 240–246. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Riaz, M.; Bösch, P.C.; Åm, M.K.; Ellingsen, R.; Hjelme, D.R.; Carlsen, S.M.; Christiansen, S.C. Effects of near-infrared photobiomodulation on local skin blood flow in healthy subjects. Photonics 2026, 13, 119. [Google Scholar] [CrossRef] [Scilit]
- Wood, C.; Cutshall, S.M.; Lawson, D.K.; Ochtrup, H.M.; Henning, N.B.; Larsen, B.E.; Bauer, B.A.; Mahapatra, S.; Wahner-Roedler, D.L. Music Therapy for Anxiety and Pain After Spinal Cord Injury: A Pilot Study. Glob. Adv. Health Med. 2021, 10, 21649561211058697. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wu, C.-C.; Chiang, J.-S.; Lee, C.-Y.; Wang, C.-Y. Feasibility of multi-wavelength LED irradiation on the skull and preliminary glycemic outcomes in individuals with type 2 diabetes: A prospective pilot study. Life 2026, 16, 1411. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.