Skip to Content
WaterWater
  • Article
  • Open Access

27 November 2026

24 Pages

Data-Driven Assessment of Pipe Class Stiffness Under Sub-Atmospheric Pressure Conditions During Water Pipeline Emptying Operations

,
,
,
and
1
Faculty of Engineering, Universidad de Cartagena, Cartagena de Indias 130001, Colombia
2
Institute of Hydraulics and Environmental Sanitation, Universidad de Cartagena, Cartagena de Indias 130001, Colombia
3
PhD Programme in Water and Environmental Engineering, Universitat Politècnica de València, 46022 Valencia, Spain
4
Faculty of Architecture and Engineering, Institución Universitaria Mayor de Cartagena, Cartagena de Indias 130001, Colombia

Abstract

During the operation of hydraulic conveyance systems, the emptying manoeuvres of pressurized pipelines represent a critical operational challenge owing to the generation of complex transient phenomena characterized by two-phase air–water interaction. These events may induce hazardous sub-atmospheric pressures, which can compromise the structural integrity of the pipeline infrastructure. The rigid water column model coupled with a polytropic law model reproduces the expansion of an entrapped air pocket during emptying operations. In this study, the Monte Carlo method was implemented to evaluate the minimum pressures and maximum velocities across 5000 transient scenarios of an emptying operation in a case study. Subsequently, thirty machine learning regression models were trained and validated using 90% of the simulated dataset to develop an efficient surrogate model capable of predicting the transient response instantaneously, with the remaining 10% reserved for independent testing. The sensitivity analysis revealed that the initial water column length and the initial volume of entrapped air exert the dominant influence on the transient extreme pressures, exceeding the relative impact of pipe diameter and valve discharge coefficient. The selected bilayered neural network reproduced the minimum pressures of the independent test set with R2 = 0.995 and RMSE = 1.42 kPa. Consequently, this computational tool provides a robust scientific framework for screening pipe stiffness classes against structural collapse risks during emptying in water conveyance infrastructure. Ultimately, this research provides a practical methodology for assessing sub-atmospheric pressure conditions and verifying the adequacy of a given pipe stiffness class under a particular transient event. The results show that, for initial air-pocket-to-water-column length ratios ranging from 0.001 to 0.1, the pressure within the pipeline can approach near-vacuum conditions.

1. Introduction

Efficient management of water distribution networks and urban drainage systems requires an understanding of the transient phenomena occurring during routine operational manoeuvres, such as pipeline filling and emptying procedures. These operations entail significant risks associated with the dynamic interaction between the water and entrapped air pockets inside the system. During emptying operations, the expansion of air pockets can cause sub-atmospheric pressure conditions, which can produce the collapse of a pipe system depending on pipe stiffness class and soil bedding conditions [1,2,3]. Recent studies have highlighted that the inadequate management of air pockets and the resulting pressure oscillations represent a source of failure in hydraulic infrastructure [4,5,6].
Modelling these two-phase flows entails inherent complexity due to the coupled, highly non-linear transient differential equations governing air thermodynamics and water column hydraulics. Historically, formulations based on rigid column theory and polytropic law, solved via systems of differential-algebraic equations (DAEs), have proven to be robust and computationally efficient tools for predicting air pocket pressure and water discharge velocity in water distribution systems [7,8]. Recent experimental investigations have validated these one-dimensional formulations against laboratory and field-scale measurements, confirming their suitability for engineering decision-making [9,10,11,12]. Furthermore, analytical and semi-analytical approaches have been proposed to resolve air–water interfaces directly, reducing the computational overhead associated with traditional numerical methods [1,13].
In one-dimensional hydraulic transients, the classical elastic formulation (method of characteristics) accounts for water compressibility and pipe wall elasticity, whereas the rigid column model assumes the liquid to be incompressible [14,15]. Nevertheless, during the emptying of pipelines containing entrapped air pockets, the high compressibility of the gaseous phase cushions the high-frequency elastic pressure waves, such that the system dynamics are predominantly governed by mass oscillation [16,17]. For this reason, coupling the rigid column model with polytropic compression provides a physically consistent and computationally efficient approach, the results of which can be compared with modelling performed using computational fluid dynamics (CFD).
CFD has emerged as a powerful tool for visualizing two-phase interactions in complex geometries in detail. Two- and three-dimensional CFD models, employing Volume of Fluid (VOF) techniques and turbulence closures such as the SST k–ω model, have enabled the analysis of interface deformation, air backflow, and energy dissipation during pipeline filling and emptying processes [18,19,20]. These advanced models have been instrumental in investigating air pocket dynamics in pipelines with irregular undulating profiles [21,22], geysering phenomena that periodically eject water and vapour [23], and the emptying of large-scale pipelines [24]. Nevertheless, the prohibitive computational overhead and execution runtime of 3D CFD simulations severely restrict their applicability to real-time simulation of extensive networks, thereby justifying the need for simplified yet accurate models implemented at numerical resolution.
Two-phase flow analysis is by no means restricted to the municipal water sector; it constitutes a pervasive challenge across diverse process industries, giving rise to an extensive corpus of literature on petroleum transport, industrial drainage, and cooling circuits [25,26]. In oil and gas pipelines, transient liquid–gas slugging and depressurization cycles demand rigorous operational control to avoid cavitation damage and structural fatigue [27,28].
In the context of advanced modelling, artificial intelligence (AI) and machine learning (ML) techniques have gained substantial momentum for resolving complex multiphase flow problems where physical closure equations are challenging to formulate. Artificial Neural Networks (ANNs), Support Vector Machines (SVMs), and deep learning algorithms have been applied to identify gas–liquid flow regimes in inclined and vertical pipes [29,30,31], predict entrained droplet fractions in annular flow [32], estimate pressure drops in micro-finned conduits [33], and forecast bottom-hole pressures in wells [34]. These techniques have also been extended to predicting phase hold-up in oil–water mixtures using microstrip sensors [35], modelling hydrodynamic cavitation for wastewater treatment [36], and evaluating transients in pumping systems equipped with air vessels [37]. Furthermore, graph neural networks (GNNs) have enabled ultra-fast urban drainage simulations, drastically outperforming conventional hydrodynamic solvers in runtime efficiency [38].
Other engineering disciplines have also contributed valuable perspectives on fluid–structure interaction and numerical simulation that enrich the present study. Detailed CFD investigations have been conducted on hydraulic fracture propagation in heterogeneous rock formations [39] and bubble dynamics in continuous casting moulds [40]. Likewise, the investigation of air pockets in horizontal ducts and parametric sensitivity in state-space formulations for energy storage offer transferable frameworks for sensitivity analysis in hydraulic networks [41,42]. Furthermore, bubbly flow diagnostics using deep learning frameworks and the prediction of condensation pressure drops and cavitating regimes demonstrate the broad versatility of data-driven and numerical methods [43,44,45].
A simulation-based surrogate framework is proposed for assessing the adequacy of pipe stiffness classes under extreme sub-atmospheric pressure conditions during water pipeline emptying. Unlike conventional approaches that rely on individual transient simulations or simplified design checks, the proposed methodology systematically combines the physical formulation of pipeline emptying with Monte Carlo sampling and machine-learning regression to enable rapid prediction across a wide range of operational conditions. A synthetic dataset comprising 5000 numerical simulations based on the rigid-column formulation is generated and used to train and compare 30 regression models implemented in MATLAB/Simulink. The best-performing model, a bilayered neural network surrogate, is subsequently validated as a computationally efficient alternative to direct numerical simulation while retaining high predictive accuracy.
The framework has two separate stages. The surrogate predicts the hydraulic extremes (Pmin and Vmax), and the allowable sub-atmospheric pressure of each pipe class is then computed analytically (Equations (13)–(16)). Previous surrogate studies addressed pipeline filling against nominal pressure classes [46] and laboratory-scale emptying with air admission [47]; the present study considers emptying with a closed upstream end, without air admission, and links the predicted loads to the buckling capacity of standard pipe classes.
The framework further incorporates SHAP-based global sensitivity analysis to quantify the influence of the governing parameters and improve the interpretability of the surrogate model. Its engineering applicability is demonstrated through the assessment of structural collapse risk for 24 standardized pipe stiffness classes under both unburied and buried conditions. The resulting framework establishes a novel link between transient hydraulic modelling, probabilistic sampling and explainable machine learning, providing an efficient decision-support methodology for selecting pipe stiffness classes under severe sub-atmospheric pressure conditions. In practice, the surrogate could support the evaluation of emptying scenarios before a scheduled drainage [46,48]; valve operating schedules and air-admission devices are not modelled here and remain extensions of this work.

2. Materials and Methods

This research presents a quantitative methodology, which is grounded in measurable numerical data by integrating mathematical formulations with controlled simulations to predict, quantify, and establish causal relationships between input parameters and key transient outputs, namely the minimum pressure and maximum drainage velocity (see Figure 1). The workflow is structured into eight blocks, systematically organized according to the methodology schematized in Figure 1.
Figure 1. Methodological workflow used in the research [2].

2.1. Pipe Configuration and Rigid Water Column Model

To simulate the dynamic behaviour of a pipeline emptying, the rigid water column model was adopted, considering a pipe configuration as depicted in Figure 2. The formulation represents a downward-sloping conduit discharging into the atmosphere through a regulating valve, whilst an entrapped air pocket expands at the upstream high point.
Figure 2. General schematic of a pipeline emptying process.
The mathematical model used to simulate a pipeline emptying process accounted for the following physical variables: pipe diameter (D), pipe slope (θ), absolute air pocket pressure ( P 1 * ) , atmospheric pressure ( P atm * ) , water density (ρw), polytropic exponent (k) (varying from 1.0 to 1.4), gravitational acceleration (g), Darcy–Weisbach friction factor (f), total pipeline length (LT), resistance coefficient of a regulating valve (Rv), and water column length (Le). The formulation presented below has been validated in large-scale conveyance systems [4,11,21,49,50]. The governing equations are solved numerically using Simulink-MATLAB R2024a [1,4,9]:
  • Rigid water column equation: this formulation represents the water movement from upstream to downstream end.
d v w dt = P 1 * − P atm * ρ w L e + g sin θ − f v w v w 2 D − R v g A 2 v w | v w | L e  
where vw is the water velocity (m/s), t is time (s), P 1 * is the absolute air pocket pressure (Pa), P atm * is the absolute atmospheric pressure (101,325 Pa), ρw is the water density, Le is the water column length (m), g is the gravitational acceleration (9.81 m/s2), θ is the pipe slope (rad), f is the dimensionless Darcy–Weisbach friction factor, D is the internal pipe diameter (m), Rv is the resistance coefficient of a regulating valve (s2/m5), and A is the pipe cross-sectional area (m2). In the Monte Carlo sampling and in the surrogate models, the valve term was parameterised through the lumped product RvA (s2/m3).
  • Polytropic expansion law for an air pocket: the thermodynamic expansion of an entrapped air pocket is governed by the polytropic gas law [51,52].
P 1 * L T − L e k = P 1 , 0 * x 0 k = constant
where LT = x0 + Le,0 is the total pipe length (m), k is the dimensionless polytropic exponent, P 1 , 0 * is the initial absolute air pocket pressure, equal to P atm * (Pa), and x0 is the initial air pocket length (m).
  • Air-water interface formulation: the interface is modelled using the piston-flow approximation [1,51]:
d L e dt = − v w   L e = L e , 0 − ∫ 0 t v w   dt
where Le,0 is the initial water column length (m).
The system composed of Equations (1)–(3) provides an accurate representation of an emptying process in water installations. Complex flow regimes have been documented in Baker’s flow pattern maps and multiphase flow literature [27,28]. Advanced pattern recognition techniques using neural networks demonstrate that flow regime transitions depend on superficial phase velocities and pipeline inclination [29,30,31].
The rigid water column model assumes an incompressible liquid and a rigid pipe, which is reasonable here because the compressibility of the air pocket governs the transient [16,17]. The piston-interface assumption treats the air–water interface as plane and normal to the pipe axis, with no air intrusion along the crown. At steep slopes, high velocities and short water columns, the interface can deform and air can enter, as analysed with CFD models [18,19,20]; the formulation is therefore intended for moderate conditions, and the scenarios near the edges of the sampled domain are model outputs. Removing the scenarios with θ > 30° or Vmax > 10 m/s (3013 remain) changes the exceedance percentages.

2.2. Monte Carlo Simulation Strategy and Sensitivity Analysis

The pipeline emptying process is analyzed considering an initially entrapped air pocket, with the governing parameters sampled over broad physically meaningful ranges defined according to the specific case study. The Monte Carlo method is employed to systematically explore the resulting combinations of hydraulic, geometric, and operational conditions, thereby capturing the interactions among the parameters that govern the transient response.
The simulations are performed in MATLAB/Simulink using the Sensitivity Analyzer of Simulink Design Optimization. For the pipeline configuration considered, consisting of a closed upstream end, seven parameters are varied to characterize the emptying process: pipe diameter (D), polytropic exponent (k), initial air-pocket length (x0), Darcy–Weisbach friction factor (f), valve resistance coefficient (Rv) multiply by the cross-sectional area (A), initial water-column length (Le), and pipe inclination angle (θ). These parameters are sampled within predefined physical ranges to generate a representative set of operating conditions for the Monte Carlo analysis. The ranges, listed in Table 1, were chosen wide enough to cover installations from small pipes up to one-kilometre pipelines, with slopes from nearly horizontal to 45°. Once the ranges of the parameters have been established, the random numbers can be generated using the following functions:
Table 1. Parameter ranges used in all simulations.
  • Normal distribution:
y i = μ + σ Φ − 1 u
where yi is the random value of the analysed parameter, u is a uniform random number between 0 and 1, Φ−1 is the inverse of the standard normal cumulative distribution function, μ is the mean of the distribution, and σ is the standard deviation.
  • Uniform distribution:
y i = a + b − a u
where a and b denote the lower and upper bounds of a parameter, respectively.
  • Exponential distribution:
y i = − b ln u
  • Weibull distribution:
y i = b − ln u 1 / a
where in Equation (7), a is the shape parameter and b is the scale parameter of the distribution.
It is important to clarify that the tool used is capable of processing the previously mentioned distributions; however, for this particular analysis, the uniform distribution was used.
The seven inputs were sampled independently; the largest Spearman correlation between two inputs in the sample is 0.027. The simulations were run in Simulink with a variable-step solver (ode45), relative tolerance 10−3, minimum and maximum steps of 1 s and 2 s, and each of the 5000 runs covered 2000 s of simulated time. No stopping criterion was needed: with the upstream end closed and no air admitted, the column never empties (the smallest Lmin among the 5000 runs is 0.25 m), and the column length is bounded below by zero. Pmin, Vmax and Lmin are the extremes over the whole run. To check them, 200 randomly selected scenarios were integrated again with an independent implementation and tighter settings (Runge–Kutta 5(4), tolerances 10−8 and 10−10, maximum step 0.1 s): the median difference in Pmin was 0.3 Pa (95th percentile 3.0 Pa, 0.022%), and the 95th percentiles for Vmax and Lmin were 0.012 m/s and 0.036 m.
The resulting simulations provide a comprehensive synthetic dataset of pipeline emptying transients, which is subsequently used to identify the parameters governing the system response and to develop the data-driven surrogate models presented in the following sections. To guarantee reproducibility and transparency in sampling and dataset partitioning, all Monte Carlo simulations and subsequent splits were executed under a fixed pseudorandom generator seed (rng(100, ‘twister’)) in MATLAB R2024a prior to scenario generation, following the methodological reproducibility guidelines established in Ortega-Heredia et al. [46].

2.3. Machine Learning Regression Models

Using a sufficiently large synthetic dataset generated via the Monte Carlo method, 30 machine learning regression models [53] can be trained using the Regression Learner app in MATLAB-Simulink, as categorized in Figure 3. The dataset was split in Regression Learner into an independent test set (10%, 500 simulations) and, from the remaining 4500, a validation hold-out (22%, 990 simulations) and a training set (3510 simulations). This partition applies to both outputs; since the saved Regression Learner session retained only Pmin, the Vmax surrogate was trained in MATLAB R2024a with the same architecture and split.
Figure 3. Categorisation of machine learning regression models.
During model training and validation, the bilayered neural network was identified as the top-performing architecture owing to its lowest root mean square error (RMSE) and highest coefficient of determination (R2). Figure 4 shows the architecture of a bilayered neural network. Model selection relied only on the validation set. The bilayered network had the lowest validation RMSE (1330 Pa) and, with 201 trainable parameters, it is lighter than the wide network (901 parameters), whose test RMSE is practically the same (1416 Pa against 1420 Pa).
Figure 4. Bilayered neural network schematic with two hidden layers of 10 neurons each (ReLU activation).
In the hidden layers, non-linear feature extraction takes place according to the following mathematical transformation:
h j = σ   Σ i = 1 7 w ji x i +   b j
where hj is the output of neuron j of the first hidden layer, σ is the ReLU activation function, σ(z) = max(0,z), wji is the weight that connects input i with neuron j, xi are the seven standardised input variables (D, k, x0, f, RvA, Le,0 and θ), and bj is the bias of neuron j. The second hidden layer applies the same transformation to the 10 outputs of the first one.
In the output layer, the information processed by the two hidden layers of 10 neurons each is consolidated into the predicted response:
y ^ =   Σ j = 1 10 v j h j +   c
where y ^ is the predicted response (Vmax or Pmin), hj is the output of neuron j of the second hidden layer, vj is its output weight, and c is the output bias.
For selecting the best-performing ML methods, the following performance metrics were considered:
  • Coefficient of determination:
R 2 = 1 − Σ i = 1 n y i − y ^ i 2 Σ i = 1 n y i − y ¯ 2
  • Root mean square error:
RMSE = 1 n   Σ i = 1 n ( y i − y ^ i ) 2
  • Mean absolute percentage error:
MAPE = 100 n   Σ i = 1 n | y i − y ^ i y i |
where yi represents the true values, y ^ i the predicted values, y ¯ the mean of measured values, and n the number of observations.
Table A1 shows the architecture, hyperparameters, and performance metric of used machine learning employed in this research.

2.4. Structural Rigidity Assessment of Normative Pipes Against Sub-Atmospheric Pressures

To translate the Monte Carlo simulation results into practical structural design verification, the maximum sub-atmospheric pressure (minimum absolute pressure) of each scenario was benchmarked against the allowable negative pressure of commercial pipes manufactured under ISO and AWWA standards. The procedure follows the nominal pressure class screening framework proposed for pipeline filling [46].
The sub-atmospheric pressure conditions in each scenario were calculated as Δ P   =   P atm *   −   P min , where Pmin corresponds to the absolute minimum pressure recorded during a transient event.
The ring stiffness of each pipe was expressed in terms of the nominal ring stiffness SN defined in ISO 9969 [54], which relates the modulus of elasticity E, the moment of inertia of the pipe wall per unit length I, and the mean diameter Dm. For pressure pipes characterised by their standard dimension ratio (SDR), stiffness was derived from this ratio and the material modulus.
SN = EI D m 3 = E 12 ( SDR − 1 ) 3
For exposed pipes or pipelines installed in open trenches, the unconfined critical buckling pressure of a long ring is pcr = 24 SN [55]. The allowable sub-atmospheric pressure was obtained by dividing this critical pressure by a safety factor SF of 2.5, in accordance with AWWA Manual M45 [56].
Δ P adm = p cr SF = 24   SN SF
For buried pipes, the surrounding soil provides lateral confinement to the pipe wall; therefore, Luscher’s buckling equation [57] was adopted as incorporated in AWWA manuals M45, M23, and M55 [56,58,59,60]. The allowable buckling pressure qa depends on the buoyancy factor Rw, the empirical soil support coefficient B′, the composite soil modulus E′, and the pipe ring stiffness SN.
q a = 1 SF 32 R w B ′ E ′   SN
The allowable sub-atmospheric pressure of the buried pipe is obtained by subtracting the static water table pressure and soil load from qa, as follows:
Δ P adm = q a − γ w h w − R w γ s H
As an example, for a GRP SN 5000 pipe buried under condition C1 (H = 1.5 m, E′ = 3 MPa, no groundwater, so hw = 0 and Rw = 1; γs = 19 kN/m3; SF = 2.5), B′ = 1/(1 + 4e−0.213H) = 0.256, with H in metres [56], and q a   =   ( 1 / 2.5 ) ( 32   ·   1   ·   0.256   ·   3 · 106   ·   5000 ) = 140.2 kPa. Subtracting the soil load γs H = 28.5 kPa gives ΔPadm = 111.7 kPa. Table A2 shows ring stiffness, reference nominal wall thickness, and allowable sub-atmospheric pressures employed in this research.
Five pipe materials widely employed in water supply systems were evaluated, comprising GRP with stiffness classes SN 2500, 5000, and 10,000 according to ISO 10639 and AWWA C950 [61,62], PVC-U from PN6 to PN20 according to ISO 1452-2 and AWWA C900 [63,64], molecularly oriented PVC (PVC-O Class 500) from PN12.5 to PN25 according to ISO 16422-2 [65], high-density polyethylene (PE100) from PN6.3 to PN20 according to ISO 4427-2 and AWWA C906 [66,67], and ductile iron (Class K9) according to ISO 2531 [68], the latter used as a rigid pipe benchmark.
The short-term moduli of elasticity were taken as 3000 MPa for PVC-U, 4000 MPa for PVC-O, 1000 MPa for PE100 and 170,000 MPa for ductile iron, whereas GRP pipes were characterised directly by their nominal stiffness class.
Short-term moduli were adopted. However, with the upstream end closed, the sub-atmospheric pressure persists after the minimum is reached until air is admitted; for loads sustained over long periods, long-term moduli would apply, and for PE100 the long-term modulus (200 MPa) would reduce the unburied capacities by a factor of five. A single safety factor of 2.5 was applied to all materials [56].
Values of the soil reaction modulus E′ were adopted from Howard’s classification [69], incorporated into AWWA design guidelines [56,58,59]. The value of 3 MPa corresponds to 400 psi (2.76 MPa), representative of fine-grained soils with moderate compaction, whereas 7 MPa corresponds to 1000 psi (6.9 MPa), typical of granular soils with well-compacted fines.
This selection agrees with geotechnical investigations for flexible conduits. Hartley and Duncan [70] demonstrated that E′ increases with trench depth, justifying moderate values for installations with 1.5 m of soil cover. Concurrently, Moore [71] experimentally validated these confined buckling formulations, and Carrier [72] confirmed that elastic buckling governs pipe sizing in shallow trenches when conduits operate under internal vacuum.
As a consistency check, the DN1000 SN 5000 GRP transmission main of Cartagena de Indias (Colombia) [2] was considered. The manufacturer specifies an allowable sub-atmospheric pressure of 0.25 bar for 10 m of cover, typical backfill and native soil. Since E′ is not reported, it was calibrated to match this limit: with SN = 5000 N/m2, H = 10 m, no groundwater (Rw = 1), γs = 19 kN/m3 and SF = 2.5, Equations (15) and (16) give 26.4 kPa for E′ = 2.7 MPa. This value agrees with Howard’s 400 psi class, consistent with the intermediate-quality embedment of condition C1. The check is a calibration, not an independent validation; the result is sensitive to E′ (18.3 kPa for 2.5 MPa and 38.2 kPa for 3.0 MPa).
Furthermore, Hurtado-Misal et al. [18] emphasized that mechanical stability during emptying fundamentally depends on burial depth, backfill compaction, and the pipe nominal stiffness class.
The screening protocol quantified, for each class and installation condition, the number of scenarios with ΔP > ΔPadm over the total of adopted simulations. These percentages reflect the uniform Monte Carlo sampling of the operational parameter space and are thus interpreted as conditional exceedance prevalences rather than unconditioned field frequencies [46].
Because the rigid water column model does not represent cavitation, the sub-atmospheric pressure used in the structural screening was bounded by the maximum physical vacuum, Δ P d   =   min Δ P ,   P atm *   −   p vap = min ( Δ P , 98.99   kPa ) . The hydraulic outputs used to train and test the surrogate were not modified.

3. Results

To evaluate the applicability of the proposed methodology and examine the influence of the initial air-pocket size, a practical application was conducted for a pipeline with an internal diameter of 300 mm and a total length of 800 m. The pipeline has a longitudinal slope of 6.9%, with f = 0.015, k = 1.2, and RvA = 5 s2/m3 (70.7 s2/m5). Three initial air pocket lengths were evaluated (x0 = 10, 50, and 90 m), representing different air-pocket-to-pipeline-length ratios. Table 1 gives the ranges of the Monte Carlo sampling.

3.1. Sample Space Characterisation and Output Distribution

Using the Sensitivity Analyzer tool in MATLAB-Simulink, 5000 simulations were executed, generating the response distributions for minimum pressure (Pmin), maximum emptying velocity (Vmax), and minimum water column length (Lmin), as summarised in Table 2.
Table 2. Sub-atmospheric pressures, maximum velocities, and minimum water column lengths in the Monte Carlo simulations.
Lmin is the shortest water column reached during the transient and coincides with the instant of maximum air pocket expansion, that is, with Pmin (Equation (2)). Because the upstream end is closed and no air is admitted, the column does not drain completely, but stops and oscillates around its equilibrium position.
In 996 simulations (19.9%), Pmin fell below the water vapour pressure, pvap = 2339 Pa at 20 °C. The rigid column model does not represent cavitation or column separation, so in these scenarios the actual absolute pressure would be bounded by pvap and the pipe would be subjected to full vacuum, P atm * − p vap = 98.99 kPa. These outputs were retained unchanged in the training, validation and test sets.
The simulation results indicated that minimum absolute pressures as low as 0.02 kPa were reached in scenarios combining small initial air pockets with long water columns, whereas velocities attained values up to 21.95 m/s in steep conduits with low valve resistance. The values predicted by the bilayered neural network and the simulated values of the maximum velocity and the minimum pressure in the validation and test stages are compared in Figure 5 and Figure 6, respectively.
Figure 5. Simulated versus predicted Vmax for (a) the validation set (n = 990) and (b) the test set (n = 500).
Figure 6. Simulated versus predicted Pmin for (a) the validation set (n = 990) and (b) the test set (n = 500).

3.2. Sensitivity Analysis: Relationship Between Input and Output Variables

Key governing parameters influencing the transient responses (Pmin) and (Vmax) were identified using Pearson and Spearman correlation coefficients between each input variable and the output responses, as presented in Table 3. Both coefficients showed consistent signs and the same two dominant variables for each output. In the case of x0, the Spearman coefficient (0.57) was more than double the Pearson coefficient (0.27), confirming a monotonic non-linear dependence between the initial air pocket dimension and the minimum sub-atmospheric pressure.
Table 3. Pearson and Spearman correlation coefficients between input and output variables (signs refer to the absolute pressure Pmin).
Figure 7a and Figure 7b show the SHAP values for Vmax and Pmin. The results demonstrate that (Pmin) is predominantly governed by two variables: the initial air pocket length (x0) and the water column length (Le). That is, smaller initial air pocket sizes combined with longer draining water columns induce more severe sub-atmospheric pressure drops. This behaviour is consistent with polytropic formulations where pressure depends directly on the length ratio, confirming previous findings that small initial air pockets present the highest risk of severe vacuum. The SHAP summary plot in Figure 7b confirms this ranking, with the water column length and the initial air pocket length as the most influential inputs.
Figure 7. Shapley summary plots of the input variables for the output variables (a) Vmax and (b) Pmin. Shapley values of a bilayered network trained on 4000 simulations, computed for the 1000 held-out simulations with 200 training simulations as background.
Conversely, Vmax is predominantly governed by the pipeline slope ( θ ) , followed by the water column length (Le), the resistance coefficient (Rv), and the Darcy–Weisbach friction factor (f). This pattern is consistent with Equation (1) of the rigid column model, where the gravitational component (g sin (θ)) serves as the primary driving force, whereas Rv and f introduce dissipative resistance terms. On the other hand, pipe diameter (D) and polytropic exponent (k) exhibited negligible correlations with both outputs, indicating a secondary influence on critical transient peaks within the sampled parameter range. The SHAP summary plot in Figure 7a confirms the dominance of the slope, followed by the water column length and the valve loss coefficient. Here, the valve contribution refers to the product RvA.
A low correlation coefficient does not exclude non-linear effects or interactions. For instance, θ has a weak linear correlation with Pmin, but Figure 7b shows that low slopes raise Pmin by up to about 40 kPa in some scenarios. These rankings apply to the ranges in Table 1.

3.3. Assessment of Critical Scenarios

Three representative operational scenarios were identified across the sampled design space, as detailed in Table 4, which are named maximum sub-atmospheric pressure (S1), minimum sub-atmospheric pressure (S2), and maximum global drainage velocity (S3).
Table 4. Critical scenarios identified in the simulations.
As a synthesis of the sensitivity analysis, Figure 8 presents the scatter matrix generated directly in the Sensitivity Analyzer tool of MATLAB/Simulink, displaying simultaneously the relationships across all 5000 simulations between each of the seven input variables (D, k, Le0, RvA, x0, θ, f) and the three critical output responses: Pmin (top row), Vmax (middle row), and Lmin (bottom row), along with their marginal distributions (histograms, right-hand column).
Figure 8. Sensitivity analysis scatter matrix (n = 5000), showing the relationship between input and output variables.
The comparative evaluation demonstrated that the bilayered neural network achieved the lowest validation error and high test accuracy, attaining an R2 of 0.995 and an RMSE of 1.42 kPa for the minimum pressure on the independent test set.

3.4. Stiffness Class Exceedance and Application Case

Table A2 (Appendix B) summarizes the nominal stiffness, wall thickness, and allowable buckling sub-atmospheric pressure for 24 normative pipe classes under three installation conditions: unburied (C0), buried in moderately compacted soil (C1, E′ = 3 MPa), and buried in well-compacted granular soil (C2, E′ = 7 MPa).
Figure 9 depicts the percentage of the 5000 Monte Carlo simulations whose maximum sub-atmospheric pressure exceeds the allowable buckling resistance (ΔP > ΔPadm) for each pipe class across the installation conditions.
Figure 9. Percentage of simulations (n = 5000) whose maximum sub-atmospheric pressure exceeds the allowable sub-atmospheric pressure of each normative class, according to installation condition.
Soil confinement markedly attenuates these exceedance percentages. With 1.5 m of compacted cover (C1), exceedances drop to 0% for almost all metallic and high-stiffness thermoplastic classes, remaining significant only for flexible GRP SN 2500 and thin-walled PVC conduits. Hydraulic transient guidelines for water distribution systems already identify sub-atmospheric pressures as a cause of pipe collapse [73].
Figure 10 correlates the maximum sub-atmospheric pressure with the dimensionless ratio x0/Le,0 across the 5000 simulations, superimposing the unburied allowable sub-atmospheric pressure of the lowest stiffness class.
Figure 10. Maximum sub-atmospheric pressure across the 5000 simulations versus the ratio x0/Le,0. The horizontal lines are the allowable sub-atmospheric pressures of the unburied pipe classes of lowest stiffness, with the percentage of simulations that exceed each of them.
When the initial air pocket is shorter than the draining water column (x0/Le,0 < 1), critical sub-atmospheric pressures are systematically generated, with a median of 95.2 kPa; for ratios between 0.001 and 0.1, 98.7% of the simulations exceed 90 kPa, close to the maximum physical vacuum. In contrast, when the ratio exceeds 1.0, the air pocket acts as a thermodynamic cushion and the median sub-atmospheric pressure drops to 27.3 kPa, although individual simulations still reach 58.1 kPa. Admitting air through air valves sized for the peak drainage discharge enlarges the air pocket and keeps the system away from this critical range [2,74].
The ratio x0/Lmin, where Lmin is the minimum water column length reached during the transient, was also examined. Because Lmin is a result of the simulation rather than an initial condition, this ratio extends up to 365 and its Spearman coefficient with ΔP falls to −0.51, compared with −0.95 for x0/Le,0. For this reason, x0/Le,0 is the variable adopted to screen pipe classes, since it is known before the emptying manoeuvre.
In the DN300 application pipeline, the maximum sub-atmospheric pressure obtained via direct integration was 100.66 kPa for case A1 (x0 = 10 m), 96.80 kPa for A2 (x0 = 50 m), and 92.27 kPa for A3 (x0 = 90 m), as presented in Table 5.
Table 5. Results of the DN300 application case (LT = 800 m, S0 = 6.9%, f = 0.015, RvA = 5 s2/m3, k = 1.2).
No local dataset was generated; the three cases lie within the ranges in Table 1 and represent a direct application of the general surrogate. Because the network trained in Regression Learner was not exported from the app, they were evaluated with a bilayered network of the same architecture (10–10, ReLU) trained in MATLAB on 80% (4000) of the same 5000 simulations (test R2 = 0.987, RMSE = 2.39 kPa on the remaining 1000).
Relative error = |ΔPNN − ΔPDI|/ΔPDI × 100, with Δ P   =   P atm *   −   P min . In case A1, the computed Pmin (0.66 kPa) is below pvap; 100.66 kPa is the unbounded model output, and 98.99 kPa was used in the structural check.
Figure 11 shows the time response obtained by direct integration, with the minimum pressure predicted by the bilayered neural network superimposed: the rapid pressure drop during the initial expansion phase (Figure 11a) and the drainage velocity evolution (Figure 11b), followed by the damped oscillation of the water column.
Figure 11. Response of the DN300 application case: (a) absolute air pocket pressure; and (b) water column velocity over time for the three initial air pocket sizes. Curves: direct integration. Markers: minimum from direct integration (circles) and from the surrogate (diamonds), the latter placed at the time of the direct-integration minimum.
Table 6 summarizes the structural safety verification across the 23 normative pipe classes for the DN300 pipeline under cases A1, A2, and A3, comparing unburied (C0) and buried (C1) conditions against the allowable sub-atmospheric pressures in Table A2.
Table 6. Verification of the 23 normative materials and classes in the DN300 pipeline.

4. Conclusions

This research introduces a novel methodology for assessing whether a pipe stiffness class is appropriate for withstanding sub-atmospheric pressure conditions during various emptying processes in water installations. This approach is applicable to water utilities within water systems.
Among the 30 regression models evaluated in Regression Learner, the bilayered neural network gave the lowest validation error and reproduced the minimum pressures of the test set with R2 = 0.995 and RMSE = 1.42 kPa. One prediction took about 0.3 ms, against about 0.5 s for one Simulink run with 2000 s of simulated time (Intel Core i5-10300H, MATLAB R2024b); these times exclude the one-off costs of generating the dataset and training the models.
The mechanical verification of ring stiffness against sub-atmospheric pressure revealed that unburied flexible conduits (such as GRP SN 2500 and thin-walled PVC) are highly vulnerable to elastic buckling during uncontrolled emptying. These findings align with experimental observations of structural flattening reported in the literature, which supports the use of air valves and controlled discharge, whose design is beyond the scope of this study.
The dimensionless ratio x0/Le,0 synthesises the overall system response by strongly correlating sub-atmospheric pressure drop with liquid column length and initial air volume (Spearman coefficient of −0.95). Whenever the initial air pocket is smaller than the drained water column, the median sub-atmospheric pressure reaches 95.2 kPa, exceeding the allowable capacity of flexible classes; admitting air during emptying would be required to avoid these conditions, and its design is left for future work.
Geotechnical confinement decisively modifies buckling tolerance. A cover depth of 1.5 m with moderate soil compaction (E′ = 3 MPa) increases the allowable sub-atmospheric pressure of the most flexible classes by up to 224% (PVC-O PN12.5), so that only GRP SN 2500 and thin-walled PVC classes still show exceedances within the sampled ranges.
In the DN300 case, the surrogate’s sub-atmospheric pressures differed from direct integration by 0.03–0.57% (29–532 Pa in absolute pressure). The pressure dropped by 90% within 17–72 s, and the minimum was reached at 196–219 s.
The surrogate estimates the hydraulic extremes in milliseconds; extending it to valve operating schedules and air-admission devices would allow water utilities to plan emptying operations, and is left for future work.
The surrogate reproduces the rigid water column model, and its test accuracy is not a field validation. Its use is limited to closed-end pipelines without air admission and to the parameter ranges in Table 1, and its accuracy in practice cannot exceed that of the underlying hydraulic model. The exceedance percentages describe the sampled ensemble and are not field failure probabilities.

Author Contributions

Conceptualization, C.D.D.-C.; methodology, C.D.D.-C. and O.E.C.-H.; software, C.D.D.-C., H.M.R., M.P.-S., and A.H.O.-H.; validation, C.D.D.-C., O.E.C.-H. and A.H.O.-H.; formal analysis, C.D.D.-C. and O.E.C.-H.; writing—original draft preparation, C.D.D.-C.; writing—review and editing, H.M.R., and M.P.-S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

The authors thank the Master’s Program in Civil Engineering at the University of Cartagena.

Conflicts of Interest

The authors declare no conflicts of interest.

Notation

A pipe cross-sectional area (m2);
B ′ empirical soil support coefficient (-);
b j bias of neuron j (-);
c bias of the output layer (-);
D pipe diameter (m);
D m mean pipe diameter (m);
E material modulus of elasticity (Pa);
E ′ composite soil reaction modulus (Pa);
f Darcy–Weisbach friction factor (-);
g gravitational acceleration (m/s2);
H soil cover depth above pipe crown (m);
h j output of neuron j of a hidden layer (-);
h w groundwater table height above pipe crown (m);
I wall moment of inertia per unit length (m4/m);
k polytropic exponent for air (-);
L e water column length (m);
L e , 0 initial water column length (m);
L min minimum water column length during the transient (m);
L T total pipe length (m);
n number of observations (-);
P 1 * air pocket pressure (Pa);
P 1 , 0 * initial absolute air pocket pressure (Pa);
P atm * atmospheric pressure (Pa);
p cr unconfined critical buckling pressure (Pa);
P min minimum pressure (Pa);
p vap water vapour pressure (Pa);
q a allowable buckling pressure of buried pipe (Pa);
R 2 coefficient of determination (-);
R v resistance coefficient of a regulating valve (s2/m5);
R w water buoyancy factor (-);
SDRstandard dimension ratio (outer diameter to thickness) (-);
SF safety factor (-);
SNnominal ring stiffness (N/m2);
t time (s);
v j output weight of neuron j (-);
V max maximum water velocity (m/s);
v w water velocity (m/s);
w ji weight between input i and neuron j (-);
x 0 initial air pocket length (m);
x i input variable i of the neural network (-);
y ^ predicted value of the response;
y ¯ mean of the simulated values;
y i simulated value of observation i;
γ s unit weight of backfill soil (N/m3);
γ w unit weight of water (N/m3);
Δ P maximum transient sub-atmospheric pressure (Pa);
Δ P d bounded sub-atmospheric pressure used in structural screening (Pa);
Δ P adm allowable pipe sub-atmospheric pressure (Pa);
θ pipe slope (rad);
ρ w water density (kg/m3);
σ ReLU activation function (-);
0subscript denoting initial condition.

Appendix A. Hyperparameters and Performance of Machine Learning Models

Table A1 summarises the model numbering, architecture, principal hyperparameters, and validation and test performance metrics across all 30 evaluated regression models.
Table A1. Architecture, hyperparameters, and performance metrics on the validation and test datasets (R2 and RMSE) of the 30 regression models evaluated in Regression Learner for Pmin prediction.

Appendix B. Ring Stiffness and Allowable Sub-Atmospheric Pressure of Standard Pipes

Table A2. Ring stiffness, reference nominal wall thickness, and allowable sub-atmospheric pressures across 24 pipe classes under three installation conditions (SF = 2.5; C0: unburied; C1 and C2: buried with H = 1.5 m and E′ = 3 and 7 MPa). Wall thicknesses for an outside diameter of 315 mm (thermoplastics) and for DN300 and DN500 (ductile iron, ISO 2531 K9) are given for reference only.

References

  1. Payares Guevara, C.R.; Patiño-Vanegas, A.; Pereira-Batista, E.; Coronado-Hernández, O.E.; Fuertes-Miquel, V.S. An Analytical Model for the Prediction of Emptying Processes in Single Water Pipelines. Appl. Sci. 2025, 15, 6000. [Google Scholar] [CrossRef] [Scilit]
  2. Coronado-Hernández, O.; Fuertes-Miquel, V.; Angulo-Hernández, F. Emptying Operation of Water Supply Networks. Water 2018, 10, 22. [Google Scholar] [CrossRef] [Scilit]
  3. Rueda, F.; Torres, J.P.; Machado, M.; Frontini, P.M.; Otegui, J.L. External pressure induced buckling collapse of high density polyethylene (HDPE) liners: FEM modeling and predictions. Thin-Walled Struct. 2015, 96, 56–63. [Google Scholar] [CrossRef] [Scilit]
  4. Fuertes-Miquel, V.S.; Coronado-Hernández, O.E.; Iglesias-Rey, P.L.; Mora-Meliá, D. Transient phenomena during the emptying process of a single pipe with water–air interaction. J. Hydraul. Res. 2019, 57, 318–326. [Google Scholar] [CrossRef] [Scilit]
  5. Zhou, L.; Liu, D.; Karney, B.; Zhang, Q. Influence of Entrapped Air Pockets on Hydraulic Transients in Water Pipelines. J. Hydraul. Eng. 2011, 137, 1686–1692. [Google Scholar] [CrossRef] [Scilit]
  6. Pozos-Estrada, O.; Pothof, I.; Fuentes-Mariles, O.A.; Dominguez-Mora, R.; Pedrozo-Acuña, A.; Meli, R.; Peña, F. Failure of a drainage tunnel caused by an entrapped air pocket. Urban Water J. 2015, 12, 446–454. [Google Scholar] [CrossRef] [Scilit]
  7. Tijsseling, A.S.; Hou, Q.; Bozkuş, Z.; Laanearu, J. Improved One-Dimensional Models for Rapid Emptying and Filling of Pipelines. J. Press. Vessel Technol. 2016, 138, 031301. [Google Scholar] [CrossRef] [Scilit]
  8. Rokhzadi, A.; Fuamba, M. Investigation of Air Pocket Behavior in Pipelines Using Rigid Column Model and Contributions of Time Integration Schemes. Water 2021, 13, 785. [Google Scholar] [CrossRef] [Scilit]
  9. Coronado-Hernández, O.E.; Fuertes-Miquel, V.S.; Besharat, M.; Ramos, H.M. Subatmospheric pressure in a water draining pipeline with an air pocket. Urban Water J. 2018, 15, 346–352. [Google Scholar] [CrossRef] [Scilit]
  10. Laanearu, J.; Annus, I.; Koppel, T.; Bergant, A.; Vučković, S.; Hou, Q.; Tijsseling, A.S.; Anderson, A.; van’t Westende, J.M.C. Emptying of Large-Scale Pipeline by Pressurized Air. J. Hydraul. Eng. 2012, 138, 1090–1100. [Google Scholar] [CrossRef] [Scilit]
  11. Chen, X.; Hou, Q.; Laanearu, J.; Tijsseling, A.S. Experimental data on filling and emptying of a large-scale pipeline. Sci. Data 2024, 11, 603. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Zhou, L.; Liu, D. Experimental investigation of entrapped air pocket in a partially full water pipe. J. Hydraul. Res. 2013, 51, 469–474. [Google Scholar] [CrossRef] [Scilit]
  13. Tijsseling, A.S.; Hou, Q.; Bozkuş, Z. Rapid Liquid Filling of a Pipe With Venting Entrapped Gas: Analytical and Numerical Solutions. J. Press. Vessel Technol. 2019, 141, 041301. [Google Scholar] [CrossRef] [Scilit]
  14. Ghidaoui, M.S.; Zhao, M.; McInnis, D.A.; Axworthy, D.H. A Review of Water Hammer Theory and Practice. Appl. Mech. Rev. 2005, 58, 49–76. [Google Scholar] [CrossRef] [Scilit]
  15. Bergant, A.; Simpson, A.R.; Tijsseling, A.S. Water hammer with column separation: A historical review. J. Fluids Struct. 2006, 22, 135–171. [Google Scholar] [CrossRef] [Scilit]
  16. Cabrera, E.; Abreu, J.; Pérez, R.; Vela, A. Influence of Liquid Length Variation in Hydraulic Transients. J. Hydraul. Eng. 1992, 118, 1639–1650. [Google Scholar] [CrossRef] [Scilit]
  17. Liu, D.; Zhou, L.; Karney, B.; Zhang, Q.; Ou, C. Rigid-plug elastic-water model for transient pipe flow with entrapped air pocket. J. Hydraul. Res. 2011, 49, 799–803. [Google Scholar] [CrossRef] [Scilit]
  18. Hurtado-Misal, A.D.; Hernández-Sanjuan, D.; Coronado-Hernández, O.E.; Espinoza-Román, H.; Fuertes-Miquel, V.S. Analysis of Sub-Atmospheric Pressures during Emptying of an Irregular Pipeline without an Air Valve Using a 2D CFD Model. Water 2021, 13, 2526. [Google Scholar] [CrossRef] [Scilit]
  19. Zhou, L.; Liu, D.; Ou, C. Simulation of Flow Transients in a Water Filling Pipe Containing Entrapped Air Pocket with VOF Model. Eng. Appl. Comput. Fluid Mech. 2011, 5, 127–140. [Google Scholar] [CrossRef] [Scilit]
  20. Martins, N.M.C.; Delgado, J.N.; Ramos, H.M.; Covas, D.I.C. Maximum transient pressures in a rapidly filling pipeline with entrapped air using a CFD model. J. Hydraul. Res. 2017, 55, 506–519. [Google Scholar] [CrossRef] [Scilit]
  21. Zhou, L.; Wang, H.; Karney, B.; Liu, D.; Wang, P.; Guo, S. Dynamic Behavior of Entrapped Air Pocket in a Water Filling Pipeline. J. Hydraul. Eng. 2018, 144, 04018045. [Google Scholar] [CrossRef] [Scilit]
  22. Zhou, L.; Liu, D.; Karney, B. Investigation of Hydraulic Transients of Two Entrapped Air Pockets in a Water Pipeline. J. Hydraul. Eng. 2013, 139, 949–959. [Google Scholar] [CrossRef] [Scilit]
  23. Li, F.; Yan, J.; Yan, H.; Tao, T.; Duan, H. 2D Modelling and energy analysis of entrapped air-pocket propagation and spring-like geysering in the drainage pipeline system. Eng. Appl. Comput. Fluid Mech. 2023, 17, 2227662. [Google Scholar] [CrossRef] [Scilit]
  24. Chen, X.; Hou, Q.; Tijsseling, A.S.; Laanearu, J.; Khu, S.T. Analyzing the Emptying Process of a Large-Scale Pipeline with Three-Dimensional CFD Simulations. J. Hydraul. Eng. 2025, 151, 04025036. [Google Scholar] [CrossRef] [Scilit]
  25. Xu, Y.; Fang, X.; Su, X.; Zhou, Z.; Chen, W. Evaluation of frictional pressure drop correlations for two-phase flow in pipes. Nucl. Eng. Des. 2012, 253, 86–97. [Google Scholar] [CrossRef] [Scilit]
  26. Ebrahimi, A.; Khamehchi, E. A robust model for computing pressure drop in vertical multiphase flow. J. Nat. Gas. Sci. Eng. 2015, 26, 1306–1316. [Google Scholar] [CrossRef] [Scilit]
  27. De Schepper, S.C.K.; Heynderickx, G.J.; Marin, G.B. CFD modeling of all gas–liquid and vapor–liquid flow regimes predicted by the Baker chart. Chem. Eng. J. 2008, 138, 349–357. [Google Scholar] [CrossRef] [Scilit]
  28. Liu, W.; Xu, Q.; Zou, S.; Chang, Y.; Guo, L. Optimization of differential pressure signal acquisition for recognition of gas–liquid two-phase flow patterns in pipeline-riser system. Chem. Eng. Sci. 2021, 229, 116043. [Google Scholar] [CrossRef] [Scilit]
  29. Lin, Z.; Liu, X.; Lao, L.; Liu, H. Prediction of two-phase flow patterns in upward inclined pipes via deep learning. Energy 2020, 210, 118541. [Google Scholar] [CrossRef] [Scilit]
  30. Rosa, E.S.; Salgado, R.M.; Ohishi, T.; Mastelari, N. Performance comparison of artificial neural networks and expert systems applied to flow pattern identification in vertical ascendant gas–liquid flows. Int. J. Multiph. Flow 2010, 36, 738–754. [Google Scholar] [CrossRef] [Scilit]
  31. Al-Naser, M.; Elshafei, M.; Al-Sarkhi, A. Artificial neural network application for multiphase flow patterns detection: A new approach. J. Pet. Sci. Eng. 2016, 145, 548–564. [Google Scholar] [CrossRef] [Scilit]
  32. Aliyu, A.M.; Choudhury, R.; Sohani, B.; Atanbori, J.; Ribeiro, J.X.F.; Ahmed, S.K.B.; Mishra, R. An artificial neural network model for the prediction of entrained droplet fraction in annular gas-liquid two-phase flow in vertical pipes. Int. J. Multiph. Flow 2023, 164, 104452. [Google Scholar] [CrossRef] [Scilit]
  33. Najafi, B.; Ardam, K.; Hanušovský, A.; Rinaldi, F.; Colombo, L.P.M. Machine learning based models for pressure drop estimation of two-phase adiabatic air-water flow in micro-finned tubes: Determination of the most promising dimensionless feature set. Chem. Eng. Res. Des. 2021, 167, 252–267. [Google Scholar] [CrossRef] [Scilit]
  34. Jahanandish, I.; Salimifard, B.; Jalalifar, H. Predicting bottomhole pressure in vertical multiphase flowing wells using artificial neural networks. J. Pet. Sci. Eng. 2011, 75, 336–342. [Google Scholar] [CrossRef] [Scilit]
  35. Sattari, M.A.; Hayati, M. Accurate and non-contact measurement of volume percentages of oil-water fluids using microstrip sensors independent of the volume of sample using artificial neural network. Flow Meas. Instrum. 2024, 97, 102621. [Google Scholar] [CrossRef] [Scilit]
  36. Ranade, N.V.; Nagarajan, S.; Sarvothaman, V.; Ranade, V.V. ANN based modelling of hydrodynamic cavitation processes: Biomass pre-treatment and wastewater treatment. Ultrason. Sonochem. 2021, 72, 105428. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Mehmood, K.; Zhang, B.; Jalal, F.E.; Wan, W. Transient flow analysis for pumping system comprising pressure vessel using unsteady friction model. Int. J. Mech. Sci. 2023, 244, 108093. [Google Scholar] [CrossRef] [Scilit]
  38. Garzón, A.; Kapelan, Z.; Langeveld, J.; Taormina, R. Evaluation of graph neural networks for urban drainage metamodeling: Key components and transferability analysis. Water Res. 2026, 290, 125079. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Xia, Y.; Qian, X.; Yang, H.; Yao, M.; Chen, J.; Tang, C. Numerical analysis of hydraulic fracture propagation in mud-sand interbedded reservoir with different bedding dip angles. Comput. Geotech. 2026, 190, 107690. [Google Scholar] [CrossRef] [Scilit]
  40. Liu, Z.Q.; Qi, F.S.; Li, B.K.; Cheung, S.C.P. Modeling of bubble behaviors and size distribution in a slab continuous casting mold. Int. J. Multiph. Flow 2016, 79, 190–201. [Google Scholar] [CrossRef] [Scilit]
  41. Vassilev, A.; Ben Hadid, H.; El Hajem, M.; Botton, V. Experimental and numerical investigation of an air pocket immersed and immobilized in a horizontal water duct flow. Int. J. Heat Fluid Flow 2007, 28, 673–682. [Google Scholar] [CrossRef] [Scilit]
  42. Chen, M.; Batlle, C.; Escachx, B.; Costa-Castelló, R.; Na, J. Sensitivity analysis and calibration for a two-dimensional state-space model of metal hydride storage tanks based on experimental data. J. Energy Storage 2024, 94, 112316. [Google Scholar] [CrossRef] [Scilit]
  43. Poletaev, I.; Tokarev, M.P.; Pervunin, K.S. Bubble patterns recognition using neural networks: Application to the analysis of a two-phase bubbly jet. Int. J. Multiph. Flow 2020, 126, 103194. [Google Scholar] [CrossRef] [Scilit]
  44. Zendehboudi, A.; Li, X. A robust predictive technique for the pressure drop during condensation in inclined smooth tubes. Int. Commun. Heat Mass Transf. 2017, 86, 166–173. [Google Scholar] [CrossRef] [Scilit]
  45. De Giorgi, M.G.; Bello, D.; Ficarella, A. An artificial neural network approach to investigate cavitating flow regime at different temperatures. Measurement 2014, 47, 971–981. [Google Scholar] [CrossRef] [Scilit]
  46. Ortega-Heredia, A.H.; Coronado-Hernández, O.E.; Fuertes-Miquel, V.S. Simulation-Driven Screening and Machine Learning Surrogate Modelling of Water Pipeline Start-Up and Filling Operations for Engineering Design Support. Designs 2026, 10, 39. [Google Scholar] [CrossRef] [Scilit]
  47. Guarda, T.; Coronado-Hernández, O.E.; Coronado-Hernández, J.R. Assessing Emptying Operations with Admitted Air in Single Pipelines Employing Machine Learning Models. Water 2026, 18, 1137. [Google Scholar] [CrossRef] [Scilit]
  48. Pothof, I.; Karney, B. Guidelines for Transient Analysis in Water Transmission and Distribution Systems. In Water Supply System Analysis—Selected Topics; InTech: London, UK, 2012. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Liou, C.P.; Hunt, W.A. Filling of Pipelines with Undulating Elevation Profiles. J. Hydraul. Eng. 1996, 122, 534–539. [Google Scholar] [CrossRef] [Scilit]
  50. Zhou, F.; Hicks, F.E.; Steffler, P.M. Transient Flow in a Rapidly Filling Horizontal Pipe Containing Trapped Air. J. Hydraul. Eng. 2002, 128, 625–634. [Google Scholar] [CrossRef] [Scilit]
  51. Coronado-Hernández, O.; Fuertes-Miquel, V.; Besharat, M.; Ramos, H. Experimental and Numerical Analysis of a Water Emptying Pipeline Using Different Air Valves. Water 2017, 9, 98. [Google Scholar] [CrossRef] [Scilit]
  52. Chaiko, M.A.; Brinckman, K.W. Models for Analysis of Water Hammer in Piping With Entrapped Air. J. Fluids Eng. 2002, 124, 194–204. [Google Scholar] [CrossRef] [Scilit]
  53. The MathWorks, Inc. Statistics and Machine Learning Toolbox User’s Guide (R2025b); The MathWorks, Inc.: Natick, MA, USA, 2025. [Google Scholar]
  54. ISO 9969:2016; Thermoplastics Pipes—Determination of Ring Stiffness. International Organization for Standardization: Geneva, Switzerland, 2016.
  55. Timoshenko, S.P.; Gere, J.M. Theory of Elastic Stability, 2nd ed.; McGraw-Hill: New York, NY, USA, 1961. [Google Scholar]
  56. AWWA. Fiberglass Pipe Design (AWWA Manual M45); American Water Works Association: Denver, CO, USA, 2014. [Google Scholar]
  57. Luscher, U. Buckling of Soil-Surrounded Tubes. J. Soil Mech. Found. Div. 1966, 92, 211–228. [Google Scholar] [CrossRef] [Scilit]
  58. AWWA. PVC Pip —Design and Installation (AWWA Manual M23); American Water Works Association: Denver, CO, USA, 2020. [Google Scholar]
  59. AWWA. PE Pipe—Design and Installation (AWWA Manual M55); American Water Works Association: Denver, CO, USA, 2020. [Google Scholar]
  60. Moser, A.P.; Folkman, S. Buried Pipe Design, 3rd ed.; McGraw-Hill: New York, NY, USA, 2008. [Google Scholar]
  61. ISO 10639:2017; Plastics Piping Systems for Pressure and Non-Pressure Water Supply—Glass-Reinforced Thermosetting Plastics (GRP) Systems Based on Unsaturated Polyester (UP) Resin. International Organization for Standardization: Geneva, Switzerland, 2017.
  62. AWWA C950; Fiberglass Pressure Pipe. American Water Works Association: Denver, CO, USA, 2020.
  63. ISO 1452-2:2009; Plastics Piping Systems for Water Supply and for Buried and Above-Ground Drainage and Sewerage Under Pressure—Unplasticized Poly(vinyl chloride) (PVC-U) Part 2: Pipes. International Organization for Standardization: Geneva, Switzerland, 2009.
  64. AWWA C900; Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. Through 60 In. (100 mm Through 1,500 mm). American Water Works Association: Denver, CO, USA, 2022.
  65. ISO 16422-2:2014; Pipes and Joints Made of Oriented Unplasticized Poly(vinyl chloride) (PVC-O) for the Conveyance of Water Under Pressure—Part 2: Pipes. International Organization for Standardization: Geneva, Switzerland, 2014.
  66. ISO 4427-2:2019; Plastics Piping Systems for Water Supply, and for Drainage and Sewerage Under Pressure—Polyethylene (PE) Part 2: Pipes. International Organization for Standardization: Geneva, Switzerland, 2019.
  67. AWWA C906; Polyethylene (PE) Pressure Pipe and Fittings, 4 In. (100 mm) Through 65 In. (1,650 mm), for Waterworks. American Water Works Association: Denver, CO, USA, 2021.
  68. ISO 2531:2009; Ductile Iron Pipes, Fittings, Accessories and Their Joints for Water Applications. International Organization for Standardization: Geneva, Switzerland, 2009.
  69. Howard, A.K. Modulus of Soil Reaction Values for Buried Flexible Pipe. J. Geotech. Eng. Div. 1977, 103, 33–43. [Google Scholar] [CrossRef] [Scilit]
  70. Hartley, J.D.; Duncan, J.M. E′ and Its Variation with Depth. J. Transp. Eng. 1987, 113, 538–553. [Google Scholar] [CrossRef] [Scilit]
  71. Moore, I.D. Elastic Buckling of Buried Flexible Tubes—A Review of Theory and Experiment. J. Geotech. Eng. 1989, 115, 340–358. [Google Scholar] [CrossRef] [Scilit]
  72. Carrier, W.D. Buckling versus Deflection of Buried Flexible Pipe. J. Geotech. Geoenvironmental Eng. 2005, 131, 804–807. [Google Scholar] [CrossRef] [Scilit]
  73. Boulos, P.F.; Karney, B.W.; Wood, D.J.; Lingireddy, S. Hydraulic Transient Guidelines for Protecting Water Distribution Systems. J. AWWA 2005, 97, 111–124. [Google Scholar] [CrossRef] [Scilit]
  74. Ramezani, L.; Karney, B.; Malekpour, A. The Challenge of Air Valves: A Selective Critical Literature Review. J. Water Resour. Plan. Manag. 2015, 141, 04015017. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.