Abstract
This study investigates the hydraulic loading, static structural response, and modal characteristics of a model-scale Francis turbine runner under six operating conditions. A steady-state Reynolds-averaged Navier–Stokes model was used to obtain the mean flow field, and the calculated pressure distributions were transferred to the runner through a one-way fluid–structure interaction (FSI) procedure. The numerical hydraulic performance was compared with model-test data at the design point and over the available experimental characteristic curves, with relative errors of 2.4% in head and 1.94% in efficiency at the design point. The results show that elevated turbulent kinetic energy mainly occurs near the suction-side middle and rear regions, trailing edge, and runner outlet under selected off-design conditions. The maximum equivalent stress under steady hydraulic loading was 29.623 MPa, below the allowable stress of 83.33 MPa; the corresponding yield-strength-to-stress ratio was 8.44. The maximum static deformation was 16.164 μm. The first six wet modal frequencies were 2.43–5.25% lower than the corresponding dry frequencies, consistent with the fluid-added-mass effect. The fourth harmonic of the nominal guide-vane-passing frequency (640 Hz) is close to the second and third wet natural frequencies (647.22 and 647.25 Hz). Since excitation amplitudes, hydrodynamic damping, and forced responses were not evaluated, the frequency comparison provides only a preliminary screening and does not establish operational resonance or fatigue safety.
1. Introduction
With the growing demand for clean energy and the ongoing transition toward low-carbon power systems, renewable energy sources such as wind and photovoltaic power have been increasingly integrated into modern power grids [1,2,3]. In response to carbon neutrality and carbon peaking targets [4,5], the increasing penetration of intermittent renewable energy has placed greater demands on power-system regulation and operational flexibility. Owing to their rapid response and flexible regulation capabilities, hydropower units play an increasingly important role in balancing power fluctuations and maintaining grid stability. Consequently, hydraulic turbines are frequently required to operate under off-design conditions, resulting in more complex internal flow patterns and structural loading characteristics [6].
When operating away from their design conditions, hydraulic turbines may experience flow separation, recirculation, and vortex development within the flow passages. These phenomena can intensify turbulent mixing and viscous dissipation, thereby increasing hydraulic energy losses. In particular, unstable flow structures in the draft tube may induce low-frequency pressure fluctuations and generate additional hydraulic excitations acting on the runner. Such excitations can affect the vibration behavior of the runner and shaft system, while also producing alternating stresses and localized stress concentrations in the blades, crown, band, and their connecting regions. Furthermore, when hydraulic excitation frequencies approach the structural natural frequencies, the possibility of vibration amplification increases. Under certain operating conditions, the development of local low-pressure regions may also promote cavitation and surface erosion. Prolonged exposure to these adverse hydraulic conditions can contribute to fatigue crack initiation and propagation, potentially compromising the structural integrity and operational reliability of hydraulic turbine units.
Considerable research has been conducted to understand the hydraulic excitation mechanisms and structural vibration characteristics of hydraulic turbines. Bi et al. [7] investigated draft-tube flow patterns and vortex-rope evolution under different load conditions, demonstrating that vortex structures were present during low-load operation and generated pronounced low-frequency pressure fluctuations in the straight-cone section. Duan et al. [8] examined the vibration responses of cracked and intact Francis turbine runners subjected to hydraulic excitation. By employing the power spectral density transmissibility (PSDT) method, they identified the characteristic response frequencies and provided a basis for runner condition monitoring. Sun et al. [9] developed a transient multi-system computational framework integrating the hydraulic turbine shaft system, governing system, and flow passage system to investigate the interactions between cavitation evolution and shaft vibration. Song et al. [10] analyzed the influence of tailwater level on the hydraulic and structural behavior of turbines under low-flow conditions. Their modal results indicated that the effective modal mass was mainly concentrated along the runner axial direction, while the natural frequencies remained higher than the dominant pressure fluctuation frequencies. In addition, Sun et al. [11] investigated shaft-system vibration during small transient load variations and found that vibration intensity was closely related to load changes and blade loading characteristics.
Besides hydraulic excitation, the structural integrity and modal behavior of turbine runners have also attracted considerable attention. Zhu et al. [12] identified penetrating cracks near the hub and trailing-edge regions of a prototype Francis turbine runner. Prototype measurements revealed pronounced vibrations under small guide-vane openings and low-head, high-load conditions, while subsequent fluid–structure interaction analysis indicated stress concentrations near the blade-to-hub and blade-to-band connections. Zhou et al. [13] combined computational fluid dynamics (CFD) simulations with particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) measurements to investigate vortex evolution and hydraulic losses in pump-turbines operating under pumping stall conditions. Their findings showed that reduced flow rates intensified flow separation and large-scale vortex structures within the guide-vane passages and draft tube, accompanied by backflow and low-frequency pressure fluctuations. Regarding the influence of surrounding water on structural dynamics, Khalfaoui et al. [14] performed coupled acoustic–structural modal analyses of high-head pump-turbines at both prototype and model scales. They established a scaling approach incorporating fluid-added-mass effects to improve the prediction of natural frequencies under partially submerged conditions. Kim et al. [15] further developed a two-way fluid–structure interaction model for a model-scale tidal turbine, demonstrating the applicability of coupled fluid and structural calculations to the prediction of hydrodynamic structural responses.
More recently, numerical investigations have extended the analysis of fluid–structure interaction and modal characteristics under different operating and loading conditions. Sun et al. [16] conducted multi-condition FSI simulations of a turbine rotor and compared its dry modal characteristics under prestressed and non-prestressed conditions with the corresponding wet modal results. Their findings indicated that the mode shapes were generally similar in the two dry modal analyses, whereas the natural frequencies decreased when the surrounding water was included, primarily due to the fluid-added-mass effect. Trivedi and Cervantes [17] reviewed developments in fluid–structure interaction research on hydraulic turbines, covering flow-induced excitation, fluid-added mass, hydrodynamic damping, and blade flutter, as well as the influence of transient operating processes on turbine fatigue loading. Tong et al. [18] proposed a multiscale mesh-generation method for transferring numerical information across different scales. Their field measurements also indicated that runner vibration could be particularly pronounced under partial-load conditions, with clearance flow providing an additional source of hydraulic excitation. Bao et al. [19] investigated the deformation, stress distribution, and modal characteristics of stay vanes, guide vanes, and runners under different operating conditions. Their results revealed potential vibration amplification associated with the proximity of certain structural natural frequencies to guide-vane-passing and runner blade-passing frequencies. Li et al. [20] examined the influence of crown-clearance thickness on the internal flow, pressure fluctuations, and axial hydraulic thrust of pump-turbines, identifying considerable flow variations and vortex formation near the labyrinth sealing region.
The above studies have provided valuable insights into hydraulic excitation, structural strength, and vibration mechanisms in hydraulic turbines. However, investigations combining the hydraulic loading characteristics, structural responses, and dry/wet modal properties of Francis turbine runners under multiple operating conditions remain relatively limited. In particular, further analysis is needed to clarify how changes in operating conditions influence the spatial distribution of hydraulic loads, the resulting stress and deformation characteristics, and the natural frequencies of runners when the surrounding water is taken into account. A systematic assessment of these aspects is important for understanding the structural behavior of runners under different hydraulic operating conditions.
Accordingly, this study investigates a model-scale Francis turbine runner under six representative operating conditions by combining steady-state CFD simulations, one-way fluid–structure interaction analysis, and coupled acoustic–structural modal analysis. First, the hydraulic performance and internal flow characteristics are examined, with particular attention to the blade surface pressure distribution and turbulent kinetic energy. Subsequently, the pressure distributions obtained from the CFD calculations are transferred to the structural domain to evaluate the runner’s equivalent stress and total deformation under combined hydraulic and inertial loading. Finally, dry and wet modal analyses are performed to identify the influence of the surrounding water on the natural frequencies and mode shapes. By integrating these analyses, the study provides a comparative assessment of the hydraulic loading, static structural response, and fluid-added-mass effects of the investigated runner. The findings are intended to improve the understanding of runner structural characteristics under different operating conditions, rather than to provide a complete evaluation of transient vibration or operational fatigue safety.
2. Numerical Method
2.1. Governing Equations for Flow Field Calculation
The governing equations for fluid flow mainly include the continuity equation, momentum equation, and energy equation. Since the temperature variation of water during the energy conversion process is negligible, the energy equation is not considered in this study. Meanwhile, water is assumed to be an incompressible fluid with constant density.
The continuity equation can be expressed as:
where ρ is the fluid density, kg/m3; u is the fluid velocity, m/s; ∇ is the Hamiltonian operator; t is the time, s.
For an incompressible fluid, the steady Reynolds-averaged momentum equation can be expressed as:
where ρ is the fluid density, kg/m3; is the mean velocity vector, m/s; , where p* is the modified mean pressure, Pa, k represents the turbulent kinetic energy; and f represents the body force per unit mass, m/s2. The effective kinematic viscosity is defined as νeff = ν + νt, where ν and νt denote the molecular and turbulent eddy kinematic viscosities, respectively. Here, νt = μt / ρ, where μt is the turbulent eddy dynamic viscosity determined using the SST k-ω turbulence model. , where
denotes the mean strain-rate tensor. This formulation incorporates the modeled Reynolds stresses through the Boussinesq eddy-viscosity approximation.
2.2. Fluid–Structure Interaction Theory
Fluid–structure interaction (FSI) involves the interaction between the fluid and structural domains through the corresponding coupling interfaces. In this study, a one-way FSI approach was adopted to evaluate the static structural response of the Francis turbine runner under steady hydraulic loading. The steady-state hydraulic pressure distributions obtained from the CFD simulations were transferred to the structural domain as external loads, together with gravitational and centrifugal loads, to calculate the equivalent stress and total deformation of the runner. The resulting structural deformation was not fed back to the CFD domain. Therefore, the present one-way FSI analysis focuses on the static stress and deformation characteristics rather than the transient dynamic response of the runner. The influence of the surrounding water on the natural frequencies and mode shapes was investigated separately through coupled acoustic–structural modal analysis.
The governing equations of fluid–structure interaction can be expressed as:
where τ is the stress, Pa; d is the displacement, m; q is the heat flux, W; T is the temperature, K; subscripts f and s denote the fluid and solid phases, respectively.
2.3. Modal Analysis Theory
The modal analysis determines the natural frequencies and relative deformation patterns of the runner from the structural mass and stiffness matrices. In a linear formulation, the equation of motion is expressed in terms of the mass, damping, and stiffness matrices, together with the displacement and external force vectors. For undamped free vibration, the governing eigenvalue problem is obtained by neglecting damping and external forcing. Its solutions provide the natural frequencies and corresponding mode shapes. In the wet analysis, coupling the runner to the surrounding acoustic fluid incorporates the inertial influence of water into the eigenvalue calculation. The resulting modes characterize the adopted structural configuration but do not quantify operating vibration amplitudes or fatigue-related cyclic stresses.
Assembly of the matrix equation for the single-degree-of-freedom (SDOF) system yields the well-known equation of motion:
In the present undamped modal analysis, the damping term was omitted to determine the natural frequencies and corresponding mode shapes of the structural system. This assumption is adopted for the eigenvalue analysis and does not imply that damping effects are negligible in the actual forced vibration response of the runner. In particular, damping can influence the vibration amplitude and dynamic stress amplification when the structure is subjected to time-dependent hydraulic excitations. With damping also omitted, the damping term becomes zero. Accordingly, the equation of motion is expressed as:
Hydraulic generating units feature complex structural configurations and multiple sources of vibration excitation. Modal analysis identifies the natural frequencies and mode shapes of these structures and supports preliminary resonance screening through comparison with relevant excitation frequencies. However, frequency separation alone does not exclude resonance associated with higher harmonics or other unsteady excitations. A comprehensive resonance assessment also requires information on excitation amplitudes, spatial coupling between the loads and structural modes, damping, and forced vibration responses.
2.4. Computational Domain Model and Mesh Discretization
A Francis turbine–generator unit was selected as the research object. A three-dimensional full-flow computational model, including the spiral case, stay vanes, guide vanes, runner, and draft tube, as well as a detailed structural model of the runner, were established using SolidWorks 2024, as shown in Figure 1. The main parameters of the hydraulic turbine are listed in Table 1. The investigated runner is a model-scale Francis turbine operated on a dedicated hydraulic test rig, with a runner inlet diameter of 430 mm and a rated head of approximately 10 m. It is not a prototype runner or a geometrically scaled replica of a specified prototype. Accordingly, the hydraulic, structural, and modal results presented in this study are specific to the investigated model, and no direct extrapolation to prototype operating conditions is attempted.
Figure 1.
Three-dimensional computational domain model of a Francis turbine.
Table 1.
Hydraulic turbine basic parameters.
For the fluid domain mesh generation, the full-flow passage of the Francis turbine was discretized using the ICEM CFD 2022 R1 platform. To improve computational accuracy and efficiency, structured hexahedral meshes were generated for the stay vanes, guide vanes, runner, and draft tube regions. Local mesh refinement was applied to critical areas, such as the guide vane profiles and runner blade profiles, to better capture complex flow characteristics. Since the spiral case does not contain an obvious tongue structure and its nose region is directly connected to the inlet passage, an unstructured tetrahedral mesh was adopted due to its better geometric adaptability.
The structural mesh of the runner was generated using ANSYS Meshing 2022 R1. Considering the large twisting angle of Francis turbine blades, an unstructured tetrahedral mesh was employed due to its superior adaptability to complex geometries. The computational domain and mesh distribution are shown in Figure 2. It should be clarified that the unstructured tetrahedral mesh of the runner refers exclusively to the structural finite-element model, whereas the runner fluid domain was discretized using a structured hexahedral mesh.
Figure 2.
The mesh schematic of computational domain.
The Y+ distributions on the runner blade and guide vane surfaces were examined to evaluate the near-wall mesh resolution and its suitability for the SST k-ω turbulence model, as shown in Figure 3. It can be observed that the maximum Y+ value on the runner blade surface is approximately 28, mainly concentrated on the suction side near the leading edge adjacent to the runner band, while the Y+ values in the remaining regions are generally within the range of 0–10. Similarly, the Y+ values on the guide vane surfaces remain below 30, with relatively high values primarily distributed on the suction side and near the trailing edge, whereas comparatively lower values are observed on the pressure side. Considering the numerous flow passage components, the complex runner geometry, and the particular flow conditions of Francis turbines, the overall Y+ distributions on the runner blade and guide vane surfaces are considered acceptable for the adopted turbulence model. The calculated Y+ distributions provide an assessment of the near-wall mesh resolution for the adopted SST k-ω model. However, the Y+ distribution alone does not establish complete viscous-sublayer resolution or eliminate near-wall discretization uncertainty [21].
Figure 3.
Distribution of Y+ values on the runner blade and guide vane blade.
The grid-independence test is performed based on the Richardson extrapolation method, and the relevant calculation formulas are given below:
where Fs is the safety factor, which is generally taken as 1.25; denotes the relative error of numerical solutions on two sets of grids; r is the grid refinement factor; l represents the convergence accuracy; φ1 and φ2 are the numerical solutions for the first and second grid sets, respectively; ε21, ε32 stands for the difference between the numerical solutions of the two grid sets.
The grid independence test for the flow field was performed by generating four mesh schemes with different numbers of elements. The hydraulic performance parameters, including efficiency and flow rate under the rated operating condition, were selected as evaluation indicators. The reliability of the selected mesh was assessed using the extrapolated values of the grid convergence index (GCI), which were required to be within 5%.
The total number of elements and the calculated hydraulic performance parameters for the four mesh schemes are presented in Table 2. The Richardson extrapolation method was performed based on the results of three consecutive mesh schemes. The detailed mesh distributions are shown in Figure 4. The mesh schemes were organized into two consecutive three-grid combinations, namely Cases 1–3 and Cases 2–4, for the grid-convergence assessment. As shown in Table 2, the predicted flow rate gradually decreases from 0.725 m3/s in Case 1 to 0.715 m3/s in Case 4, indicating reduced sensitivity to further mesh refinement. The relative difference in flow rate between Cases 3 and 4 is approximately 0.14%. Considering the observed stabilization of the hydraulic performance predictions and the computational cost, Case 3, containing approximately 8.46 million cells, was selected for the subsequent simulations.
Table 2.
Detailed information of each mesh case.
Figure 4.
Grid display of different schemes.
The mesh independence test of the structural domain was also performed based on the Richardson extrapolation method. Three mesh schemes with different numbers of elements, consisting of 463,800, 573,000, and 710,400 elements, were generated for the runner model and evaluated. The mesh independence verification results of the three schemes are presented in Table 3. The calculated axial displacement and equivalent stress results, corresponding to numerical solutions A and B, were selected as evaluation indicators. The results show that when the number of elements reached 573,000 in Case 2, the extrapolated GCI values for axial displacement and equivalent stress were 4.84% and 3.24%, respectively, both satisfying the requirement of GCI <5%. Therefore, considering the balance between computational cost and solution accuracy, Case 2 was selected for subsequent structural analyses.
Table 3.
Grid-independence verification of the runner mesh.
2.5. Numerical Setup
Steady incompressible RANS calculations were performed in ANSYS Fluent 2022R1 with the SST k–ω turbulence closure. The SIMPLEC procedure coupled pressure and velocity, while gradients were reconstructed using the least-squares cell-based method. Pressure was treated with a second-order spatial scheme, and second-order upwind discretization was applied to momentum and the two turbulence transport equations. A pressure boundary corresponding to the specified hydraulic head was imposed at the inlet, and the outlet gauge pressure was zero. Inlet turbulence intensity and turbulent viscosity ratio were set to 5% and 10, respectively; the solid walls satisfied the no-slip condition. Convergence was monitored using a scaled residual criterion of 10−4. Six operating conditions were investigated, and their corresponding hydraulic parameters are summarized in Table 4. The discharge values in table were obtained from the converged pressure-driven solutions rather than separately specified as boundary conditions.
Table 4.
Operating conditions and calculated hydraulic performance parameters of the Francis turbine.
To investigate the effects of different operating conditions on the hydraulic and structural characteristics of the Francis turbine runner, six operating conditions were selected and divided into two comparative groups. The first group (OP1–OP4) was designed to investigate the influence of load variation under constant-head conditions, with hydraulic heads ranging from 9.73 to 9.89 m. The second group (OP4–OP6) was established to compare the hydraulic and structural responses of the runner under different hydraulic head conditions, including near-rated-head (OP4), low-head (OP5), and high-head (OP6) operation. For operating conditions OP4–OP6, the initial objective was to maintain the same power output to facilitate a comparative analysis under different hydraulic heads. However, the turbine could not achieve 100% of the rated power output at the minimum head. Therefore, the maximum achievable power output condition at the minimum head (OP5) was selected for the comparative analysis. OP4 was selected as the common reference condition for both groups. Since the flow rate and guide-vane opening also vary among OP4–OP6, the differences in structural responses reflect the combined influence of the operating parameters rather than the isolated effect of hydraulic head.
In Table 4, the guide vane opening refers to the diameter of the opening circle corresponding to the specified guide-vane configuration, rather than the fixed pitch-circle diameter of the guide-vane axes. The unit output represents the power obtained from the numerical simulations. The relative power output is defined as the ratio of the calculated power output to the rated power of 65 kW, expressed as a percentage. The hydraulic efficiency is defined as the ratio of the calculated turbine power output to the corresponding hydraulic input power of the water flow, determined from the hydraulic head and flow rate.
The structural field calculation is performed based on ANSYS Mechanical 2022R1. The runner is made of material ZG20SiMn, whose material parameters are listed in Table 5. According to the actual operating conditions of the runner, four constraint conditions are presented in Figure 5. A fixed constraint is applied at the connection between the runner crown and the main shaft to control the displacement of the runner structure by locking all degrees of freedom, as marked by C in the figure. The remaining boundary conditions are loads, which consist of inertial loads and fluid loads. The inertial loads include the self-weight of the runner acting along the negative Z-axis and the centrifugal force generated by rotation at the rated rotational speed of 600 r/min, as indicated by A and B in the figure. The fluid load represents the impact of water flow on the blades. Based on the numerical solutions of flow field under various operating conditions, pressure data are mapped through the fluid–solid coupling interface, and the fluid–solid coupling calculation is carried out by means of the step-by-step solution method, as shown by D in the figure. The blade pressure for each operating case is obtained from the flow-field calculation results.
Table 5.
Mechanical properties of ZG20SiMn.
Figure 5.
Boundary conditions for runner calculation.
The one-way FSI approach was adopted in this study considering the relatively small structural deformation of the runner under steady hydraulic loading. According to the calculated structural responses, the maximum total deformation among the six operating conditions was 16.164 μm, corresponding to approximately 0.0038% of the runner inlet diameter of 430 mm. This relatively small deformation suggests that the overall geometric changes of the runner are limited under the investigated steady loading conditions, providing a qualitative justification for neglecting deformation feedback to the flow field in the present static structural assessment. Nevertheless, a dedicated two-way FSI sensitivity analysis was not performed, and the potential influence of localized deformation on the surrounding flow cannot be completely excluded. Furthermore, the present one-way FSI analysis does not account for transient hydraulic excitation, fluid damping, or dynamic stress amplification.
The dry and wet modal analyses were performed using ANSYS Mechanical 2022R1. For the dry modal analysis, the natural frequencies and corresponding mode shapes of the runner were calculated without considering the surrounding water. For the wet modal analysis, a coupled acoustic–structural approach was adopted using the ANSYS Modal Acoustics module. A cylindrical computational domain enclosing the entire runner was established, with the runner represented as an elastic solid and the surrounding water modeled using acoustic fluid elements. Fluid–structure coupling interfaces were defined along the wetted runner surfaces to account for the interaction between structural vibration and the surrounding water, thereby incorporating the fluid-added-mass effect into the coupled eigenvalue analysis. The cylindrical acoustic domain was used to approximate the surrounding water environment rather than the entire hydraulic flow passage. Rotational and gyroscopic effects were not considered in the modal analyses.
3. Results and Discussion
3.1. Validation of Numerical Results with Experimental Data
Figure 6 compares the numerical and experimental results of the hydraulic head and efficiency under different relative flow rates. Overall, good agreement is observed between the simulated and measured hydraulic heads across the investigated operating conditions, indicating that the numerical model reasonably reproduces the variation in head with relative flow rate. The predicted efficiency also follows the experimental trend, showing a consistent increase with increasing flow rate. In particular, the numerical results capture the overall efficiency variation under medium- and high-flow conditions with relatively small deviations from the experimental data. Although discrepancies remain at certain operating points, the overall agreement in both hydraulic head and efficiency demonstrates that the numerical model can reliably reproduce the external hydraulic characteristics of the investigated turbine within the studied operating range. This provides a sound basis for subsequent internal flow-field analysis and one-way fluid–structure interaction calculations.
Figure 6.
Numerical calculation results and experimental data validation.
Although Figure 6 demonstrates good agreement between the numerical and experimental external hydraulic characteristics over the available test range, the reported relative errors of 2.4% in hydraulic head and 1.94% in efficiency correspond to the design operating point. The present validation therefore primarily supports the prediction of global hydraulic performance. However, local pressure distributions and turbulent kinetic energy under off-design conditions, as well as structural stress and modal characteristics, have not been independently validated because corresponding experimental measurements are unavailable.
3.2. Blade Surface Pressure and Turbulent Kinetic Energy Distributions
Figure 7 compares the mean-pressure distributions on the runner blades for OP1–OP6. Across the six cases, relatively high pressures occur near the outer inlet and leading-edge regions, whereas lower values are generally found toward the inner outlet and the rear suction-side surface. In OP1 and OP2, the low-pressure region remains relatively confined; in OP3 and OP4, it expands toward the middle and downstream portions of the blade, producing more localized pressure gradients. OP5 retains an extensive high-pressure area near the inlet, while OP6 shows a different distribution of low pressure near the outlet and suction side. The comparison indicates that changing operating conditions redistributes hydraulic loading across the blade rather than producing a uniform increase in surface pressure.
Figure 7.
Blade pressure contour maps under various operating conditions.
Figure 8 presents the pressure load distributions on the runner blades under different operating conditions. In the figure, Streamwise represents the normalized chordwise position from the blade leading edge to the trailing edge, while Spanwise represents the normalized spanwise position from the hub side to the shroud side. To investigate the variation in blade loading along the spanwise direction, five normalized positions (Spanwise = 0.1, 0.3, 0.5, 0.7, and 0.9) were selected, and the corresponding blade surface pressure distributions were extracted. By comparing the pressure load curves at different spanwise locations, the pressure variation characteristics in the leading-edge, middle, and trailing-edge regions were analyzed, providing insights into the spanwise load distribution and local pressure gradient variations.
Figure 8.
Load diagram of rotor blades under various operating conditions.
The pressure load curves under all operating conditions exhibit significant variations along the chordwise direction. A pronounced pressure change occurs near the leading edge, indicating that this region experiences strong hydraulic loading due to the influence of blade geometry and incoming flow direction. With increasing Streamwise position, pressure peaks appear in the middle section or near the outlet region under some operating conditions, suggesting variations in the pressure gradient and pressure recovery process in the middle and downstream sections.
Under OP1 and OP2 conditions, the pressure load curves at the five spanwise positions remain relatively smooth. After a certain pressure variation near the leading edge, the pressure gradually develops along the flow direction without obvious local peaks in the middle and rear sections. This behavior agrees well with the pressure contour distributions, where the high- and low-pressure regions exhibit clear boundaries and smooth transitions.
Under OP3 conditions, obvious pressure peaks appear in the middle section at some spanwise positions, indicating enhanced pressure gradients in this region. This phenomenon corresponds to the expansion of the low-pressure region on the suction side toward the middle and rear sections observed in the pressure contours. Under OP4 conditions, pressure increases occur near the outlet region (Streamwise close to 1.0) at some spanwise locations, indicating that the blade loading is shifted toward the middle-rear and outlet regions.
Under OP5, the blade leading-edge region exhibits higher loading, and relatively large pressure differences remain in the middle and rear sections at some spanwise positions. Both the inlet and middle regions contribute significantly to pressure conversion, and the combined effects of the high-pressure region near the outer edge and the low-pressure regions on the suction side and outlet determine the development of the pressure load curves. Under OP6, noticeable pressure peaks appear near the trailing edge at some spanwise positions, indicating that the outlet region still contributes to pressure recovery.
Overall, the blade surface pressure distributions exhibit three characteristic features: (1) pronounced pressure variations near the leading edge associated with the adjustment of the incoming flow; (2) spatial pressure variations in the middle section related to local pressure gradients and the development of low-pressure regions on the suction side; and (3) changes in pressure near the trailing edge associated with the outlet flow conditions and pressure recovery. It should be noted that these variations represent spatial pressure distributions obtained from steady-state CFD simulations rather than time-dependent pressure fluctuations.
Figure 9 presents the turbulent kinetic energy (TKE) distributions at three spanwise sections (Spanwise = 0.1, 0.5, and 0.9) under different operating conditions, representing the flow characteristics near the crown side, middle span, and band side, respectively. Overall, relatively high TKE values are mainly concentrated in the middle and rear sections of the suction side, near the blade trailing edge, and in the runner outlet region. These high-TKE regions indicate areas of enhanced modeled turbulent fluctuations and are potentially associated with local shear layers, flow nonuniformity, and wake-related mean-flow features. However, since the present simulations were performed using the steady-state RANS approach, the calculated TKE distributions represent modeled turbulence statistics rather than instantaneous vortex structures or their temporal evolution. The local TKE magnitude cannot be directly regarded as a quantitative measure of the overall hydraulic losses, since the turbine efficiency is influenced by the combined effects of flow conditions throughout the entire hydraulic passage.
Figure 9.
Blade turbulent kinetic energy distribution under various operating conditions.
Under the rated-head conditions, the TKE levels are relatively low in OP1 and OP2, with elevated values mainly confined to the trailing-edge and outlet regions. The high-TKE regions extend toward the middle and rear suction-side sections in OP3 and become more pronounced in OP4, particularly near the outlet and band side. Under the minimum-head condition (OP5), high TKE remains localized near the trailing edge and outlet, whereas under the maximum-head condition (OP6), elevated values are mainly observed in the middle span and near the band-side trailing-edge region.
Because the present CFD simulations are based on steady-state RANS, the TKE contours describe modeled time-averaged turbulence levels rather than time-resolved pressure fluctuations. TKE is therefore used here to identify regions of enhanced turbulent mixing; it is not treated as a direct quantitative measure of hydraulic energy loss or pressure-pulsation amplitude.
The spatial distribution of elevated TKE does not exhibit a simple one-to-one correspondence with the overall hydraulic efficiency. For instance, OP5 has a lower efficiency (88.5%) than OP4 (90.6%), whereas OP6 achieves the highest efficiency (91.7%) despite exhibiting elevated TKE in the middle-span and band-side trailing-edge regions. This further indicates that local TKE distributions should be interpreted as indicators of modeled turbulence intensity rather than direct measures of integrated hydraulic losses.
3.3. Analysis of Runner Equivalent Stress and Total Deformation
The equivalent stress distributions of the runner under different operating conditions are presented in Figure 10, where the locations of the maximum stress values are marked with red square labels. The maximum equivalent stresses under the six operating conditions are 15.845, 16.219, 19.358, 26.873, 23.789, and 29.623 MPa, respectively. In all cases, the peak stresses are concentrated near the junction between the blade trailing edge and the runner crown. This consistent stress concentration pattern may be attributed to the combined effects of local geometric transitions and hydraulic load transmission between the blade and the crown. However, the magnitude of the local peak stress may also be influenced by the structural boundary conditions and mesh resolution. The concentration of stress at the blade–crown junction is consistent with the combined influence of local geometry, structural constraints, and hydraulic loading. From OP1 to OP4, the maximum equivalent stress increases from 15.845 to 26.873 MPa, corresponding to an increase of 69.60%. These conditions have approximately similar heads but increasing flow rates and guide vane openings, indicating a combined influence of operating conditions on the structural response. From OP4 to OP6, the maximum equivalent stress increases by 10.23%, reaching 29.623 MPa. However, the head increases from 9.89 to 11.82 m, while the flow rate decreases from 0.67 to 0.53 m3/s and the guide vane opening decreases from 40 to 28 mm. Therefore, this comparison reflects the combined effects of the operating parameters rather than the isolated influence of head.
Figure 10.
Equivalent stress distribution under various operating conditions.
The reported maximum equivalent stress is based on the adopted structural mesh and boundary conditions. Although the stress concentration consistently appears near the blade trailing edge–crown junction under all six operating conditions, local geometric transitions and imposed structural constraints may lead to elevated numerical stresses or potential stress singularities. Since a dedicated local mesh-convergence study or submodeling analysis was not performed, the mesh independence of the local peak stress cannot be conclusively established. Therefore, the identified region should be regarded as a potential structural stress concentration zone, while the exact peak stress magnitude requires further verification through localized mesh refinement.
The allowable stress method was adopted to evaluate the structural strength of the runner. According to the material mechanical property standards, the specified yield strength of the runner material ZG20SiMn is σs = 250 MPa. Based on the design criterion with a safety factor of n = 3, the allowable stress limit was determined as [σ] = σs / n = 83.33 MPa. The maximum equivalent stress among the six operating conditions is 29.623 MPa, corresponding to 35.55% of the allowable stress and a remaining reserve of 64.45%. These results indicate that the runner satisfies the adopted static-strength criterion under the investigated loading conditions. However, this static-strength assessment does not establish fatigue safety or exclude crack initiation under cyclic loading. A quantitative fatigue assessment would additionally require cyclic stress histories, applicable material fatigue data, and a defined operating load spectrum.
To further investigate the stress distribution characteristics of the runner blade, a single blade was selected for detailed analysis, as shown in Figure 11. The maximum equivalent stress is also located at the junction between the blade trailing edge and the crown, which is consistent with the overall stress distribution results. Furthermore, the stress concentration is mainly distributed at the connection regions between the blade and the crown as well as between the blade and the band, indicating significant local stress concentration effects in these areas.
Figure 11.
Equivalent stress distribution for a single blade under various operating conditions.
The total deformation distributions of the runner under different operating conditions are presented in Figure 12, where the locations of maximum deformation are indicated. The maximum deformation is mainly concentrated in the middle region of the blade trailing edge and near the runner band edge. The maximum total deformations under OP1–OP6 are 7.975, 4.377, 7.936, 12.439, 9.360, and 16.164 μm, respectively, exhibiting a non-monotonic variation with operating conditions. Notably, the maximum deformation decreases from 7.975 μm under OP1 to 4.377 μm under OP2, despite the increase in flow rate and power output. This behavior suggests that the deformation is not solely governed by the overall hydraulic load magnitude but is also influenced by the spatial distribution and direction of hydraulic pressure, as well as structural constraints. Although the centrifugal loading remains unchanged at the constant rotational speed, variations in hydraulic loading may lead to different local deformation responses. Similarly, the decrease in deformation from OP4 to OP5 further illustrates the combined influence of operating parameters. However, the individual contributions of these factors were not quantified in the present study.
Figure 12.
Total deformation distribution under various operating conditions.
The single blade is selected to investigate the distribution of maximum total deformation, as shown in Figure 13. It can be observed that the maximum total deformation of the runner blade occurs at the middle region of the blade trailing edge or at the junction between the blade and the band, which corroborates the above-mentioned analysis results.
Figure 13.
Total deformation distribution for a single blade under various operating conditions.
3.4. Dry and Wet Modal Analysis of the Runner
The modal characteristics of the runner are determined by its material properties, structural configuration, and mechanical constraints. In the present study, dry and wet modal analyses were performed for an idealized non-rotating configuration, without considering centrifugal prestress, gyroscopic effects, or the detailed dynamic characteristics of the shaft–bearing system. The first six natural frequencies and corresponding mode shapes were extracted for evaluation. Therefore, the calculated modal frequencies should be interpreted as those of the adopted numerical configuration rather than the operating natural frequencies under all six hydraulic conditions. A preliminary frequency-separation assessment was performed by comparing these frequencies with the nominal characteristic excitation frequencies.
Based on the dry and wet modal analysis results, the first six natural frequencies under both conditions are summarized in Table 6. An influence coefficient was defined as the ratio of the wet modal frequency to the corresponding dry modal frequency, which was used to evaluate the effect of the surrounding water on the dynamic characteristics of the runner.
Table 6.
First six orders of natural frequencies for dry and wet modes.
The first six wet modal frequencies are lower than the corresponding dry modal frequencies, with reductions ranging from approximately 2.43% to 5.25%. This trend is consistent with the added-mass effect of the surrounding water. In the coupled acoustic–structural formulation, the interaction between the vibrating runner and the acoustic fluid domain modifies the effective inertia of the coupled system, leading to changes in the calculated natural frequencies. The differences in frequency reduction among individual modes indicate that the influence of the surrounding water depends on the corresponding structural deformation patterns and fluid–structure coupling characteristics. It should be noted that the present modal analysis did not include hydrodynamic damping or rotational effects. Therefore, the frequency reductions should primarily be interpreted in terms of fluid-added-mass effects rather than damping-induced attenuation of vibration amplitudes.
Near-degenerate modal pairs are observed in both the dry and wet modal results. In particular, the second and third dry natural frequencies are 683.05 and 683.06 Hz, while the fourth and fifth frequencies are both 711.57 Hz. Similar frequency pairs are observed in the wet modal results at 647.22/647.25 Hz and 680.21/680.31 Hz. This near-degeneracy may be associated with the approximately cyclic structural symmetry of the runner, in which vibration modes with different circumferential phase distributions can exhibit similar natural frequencies. However, the corresponding nodal-diameter orders and modal orthogonality were not independently evaluated. Therefore, the physical classification of these paired modes requires further verification.
The first six dry modal shapes of the runner are presented in Figure 14. The results show that the first-order mode mainly exhibits rotational deformation of the band around the shaft axis, accompanied by torsional deformation of the blades. The second- and third-order modes show similar deformation characteristics, which are mainly characterized by the oscillation of the band and bending deformation of the blades.
Figure 14.
First six mode shapes of dry modes.
The fourth- and fifth-order modes also exhibit similar vibration characteristics, dominated by the lateral oscillation of the band and bending deformation of the blades. The sixth-order mode mainly represents the overall downward displacement of the runner structure. The maximum deformation in the dry modal analysis is primarily located at the edge region of the runner band.
The deformation patterns in Figure 14 and Figure 15 represent scaled modal eigenvectors. Their amplitudes should not be interpreted as actual operating displacements. The plots are used to identify the relative spatial distribution of displacement within each mode, rather than to compare physical vibration amplitudes between modes.
Figure 15.
First six mode shapes of wet modes.
The first six wet modal shapes of the runner are presented in Figure 15. The results indicate that the first-order wet mode mainly exhibits rotational deformation of the band around the shaft axis, accompanied by torsional deformation of the blades. The second- and third-order modes show similar deformation characteristics, which are mainly associated with the oscillation of the band and bending deformation of the blades.
The fourth- and fifth-order modes exhibit similar vibration characteristics, mainly characterized by local bending deformation of the band around the horizontal axis. The sixth-order mode is primarily associated with local bending deformation of the band surface. The maximum deformation in the wet modal analysis is mainly located at the middle region of the blade trailing edge.
It should be noted that the present modal analysis was limited to the first six natural frequencies and corresponding mode shapes. Higher-order modes and effective modal mass contributions were not evaluated; therefore, potential resonance involving higher-order structural modes and excitation harmonics cannot be completely excluded. Future studies should incorporate a wider modal frequency range and effective modal mass analysis to provide a more comprehensive assessment of the runner’s dynamic characteristics.
The vibration characteristics analysis indicates that the Francis turbine runner exhibits typical multi-degree-of-freedom coupled vibration behaviors under both dry and wet modal conditions. Based on the modal analysis results, the characteristic vibration modes of the runner can be classified into four categories: (1) circumferential oscillation mode, characterized by periodic deflection of the runner body around the main shaft axis; (2) radial torsional mode, characterized by alternating phase-angle displacements between adjacent blades; (3) rigid-body translation mode, characterized by consistent phase displacement in the axial direction; and (4) overall rotational mode, representing synchronous rotational deformation of the runner system around the flow passage axis.
To provide a preliminary assessment of potential resonance-related frequency interactions, several characteristic frequencies were calculated based on the rated rotational speed and the numbers of guide vanes and runner blades. These include the rotational frequency, nominal guide-vane passing frequency, and runner blade passing frequency. It should be emphasized that these frequencies were determined from kinematic relationships rather than extracted from pressure-pulsation spectra. Since the CFD simulations were performed using the steady-state RANS approach, the amplitudes and spectral characteristics of unsteady hydraulic excitations were not obtained in the present study.
(1) Rotational frequency of the unit f1.
The rotational frequency of the turbine unit can be calculated as:
where n is the rated rotational speed, which is 600 r/min.
The calculated rotational frequency is f1 = 10 Hz.
The frequency of 10 Hz represents the nominal runner rotational frequency calculated from the rated rotational speed of 600 rpm. It does not represent an experimentally measured or numerically identified draft-tube vortex-precession frequency. Since the present CFD simulations were performed using steady-state RANS, the actual vortex-precession frequency and associated pressure-pulsation spectra were not determined.
(2) Pressure fluctuation frequency induced by non-uniform flow at the guide vane outlet f2.
The pressure fluctuation frequency caused by the non-uniform flow at the guide vane outlet is calculated as:
where Zgv represents the number of guide vanes, which is 16.
The corresponding hydraulic excitation frequency is f2 = 160 Hz.
(3) Runner blade passing frequency f3.
The runner blade passing frequency can be calculated as:
where Zr represents the number of runner blades, which is 13.
The calculated blade passing frequency is f3 = 130 Hz.
Based on the rated rotational speed of 600 rpm, the runner rotational frequency was calculated to be 10 Hz. Considering the 13 runner blades and 16 guide vanes, the nominal blade-passing and guide-vane passing frequencies were determined to be 130 and 160 Hz in the stationary and rotating reference frames, respectively. These fundamental frequencies are lower than the first wet natural frequency of 377.14 Hz and do not directly coincide with the calculated natural frequencies. However, higher-order excitation harmonics may approach certain structural modes. For example, the fourth harmonic of the guide-vane passing frequency (640 Hz) is close to the second and third wet natural frequencies of 647.22 and 647.25 Hz, respectively. Nevertheless, frequency proximity alone does not establish resonance, as the actual dynamic response also depends on excitation amplitudes, spatial compatibility between excitation patterns and mode shapes, and damping characteristics. In addition, potential low-frequency hydraulic excitations associated with draft-tube flow phenomena were not quantified in the present steady-state CFD simulations. Therefore, the current frequency comparison provides only a preliminary resonance screening, and further transient pressure analysis, damping evaluation, and structural forced-response calculations are required for a comprehensive assessment of operational resonance risk.
4. Conclusions
In this study, a Francis turbine runner was selected as the research object. A combined approach involving CFD numerical simulation, one-way fluid–structure interaction (FSI) analysis, and dry/wet modal analysis was employed to investigate the hydraulic loading, structural strength, deformation characteristics, and vibration behavior of the runner under six typical operating conditions. The main conclusions are summarized as follows:
(1) The maximum equivalent stress under the investigated steady hydraulic loading conditions was 29.623 MPa, located near the blade trailing-edge–crown junction. This value is below the allowable stress of 83.33 MPa determined using a design safety factor of 3. The corresponding yield-strength-to-stress ratio is approximately 8.44. However, the local peak stress requires further verification through mesh refinement, and the present static analysis does not establish fatigue safety under cyclic hydraulic loading.
(2) The maximum total deformation was 16.164 μm and occurred near the blade trailing-edge and runner-band regions. The deformation varied non-monotonically among the six operating conditions, indicating that the response depends on the spatial distribution of hydraulic pressure and the structural constraints, rather than on the overall load magnitude alone. These locations may be considered in future structural assessment and monitoring.
(3) The first six wet natural frequencies ranged from 377.14 to 720.78 Hz and were 2.43–5.25% lower than the corresponding dry frequencies. This reduction is primarily associated with the added mass of the surrounding water. The modal deformation plots represent scaled eigenvectors rather than actual operating displacement amplitudes. Hydrodynamic damping and effective modal mass were not evaluated.
(4) The nominal rotational, runner blade-passing, and guide-vane-passing frequencies were 10, 130, and 160 Hz, respectively. The fourth harmonic of the guide-vane-passing frequency (640 Hz) is close to the second and third wet natural frequencies (647.22 and 647.25 Hz). Frequency proximity alone does not demonstrate resonance; excitation amplitudes, mode-shape compatibility, and damping must also be considered. Because the present study used steady-state CFD and one-way static FSI, transient pressure spectra and dynamic stress amplification were not evaluated. Further transient CFD, forced-response, fatigue, and, where necessary, two-way FSI analyses are required.
Author Contributions
Conceptualization, Y.L. (Youping Li) and C.L.; methodology, J.L. and C.L.; software, L.Z.; validation, Y.L. (Yongbo Li) and W.Z.; formal analysis, L.Z.; writing—original draft preparation, L.Z.; writing—review and editing, Y.L. (Youping Li), C.L., H.L., Z.Z., W.Z. and Y.Z.; visualization, L.Z.; supervision, Y.L. (Youping Li) and Y.Z. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Natural Science Foundation of Hubei Province of China (Grant No. 2024AFD353).
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding authors.
Conflicts of Interest
Authors Youping Li, Yongbo Li, Hu Li and Zhi Zhang were employed by China Yangtze Power Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as potential conflicts of interest. The authors declare that this study received funding from the Hubei Provincial Natural Science Foundation of China. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.
References
- Qin, D.; Wu, X.; Zhang, J.; Wang, X.; Yan, N. Hydraulic Optimisation Design of Axial Flow Pump Based on Blade Velocity Distribution. Int. J. Hydromechatron. 2023, 6, 311–324. [Google Scholar] [CrossRef] [Scilit]
- Choi, P.J.; Lee, J.; Jang, A. Interconnection between Renewable Energy Technologies and Water Treatment Processes. Water Res. 2024, 261, 122037. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ma, W.; Zhao, Z.; Yang, J.; Lai, X.; Liu, C.; Yang, J. A Transient Analysis Framework for Hydropower Generating Systems under Parameter Uncertainty by Integrating Physics-Based and Data-Driven Models. Energy 2024, 297, 131141. [Google Scholar] [CrossRef] [Scilit]
- Erdogan, S.; Pata, U.K.; Solarin, S.A. Towards Carbon-Neutral World: The Effect of Renewable Energy Investments and Technologies in G7 Countries. Renew. Sustain. Energy Rev. 2023, 186, 113683. [Google Scholar] [CrossRef] [Scilit]
- Wang, W. Green Energy and Resources: Advancing Green and Low-Carbon Development. Green Energy Resour. 2023, 1, 100009. [Google Scholar] [CrossRef] [Scilit]
- Wu, Y.; Li, C.; Wang, X.; Zhu, G. Study on the Influence of Tip Clearance of Tidal Tubular Turbine on Pressure Pulsation of Draft Tube. IOP Conf. Ser. Earth Environ. Sci. 2021, 766, 012026. [Google Scholar] [CrossRef] [Scilit]
- Bi, H.; Lu, Y.; Wang, Z.; Yu, J. Research on Hydraulic Excitation Characteristics of Draft Tube in Giant Hydraulic Turbine under Low-Load Conditions. J. Phys. Conf. Ser. 2025, 3150, 012143. [Google Scholar] [CrossRef] [Scilit]
- Duan, J.; Huang, J.; Peng, Z.; Chen, L.; Qian, J.; Zeng, Y. Identification of Hydro-Turbine Runner with Cracked Blade Based on Power Spectral Density Transmissibility in Operation. Eng. Appl. Comput. Fluid Mech. 2025, 19, 2597950. [Google Scholar] [CrossRef] [Scilit]
- Sun, J.; Feng, C.; Zhang, Y.; Zheng, Y. Transient Vibration Analysis of Multi-System Coupling in Pumped Storage Power Stations: Insights into Cavitation-Induced Flow and Shaft Dynamics. Energy 2025, 328, 136516. [Google Scholar] [CrossRef] [Scilit]
- Song, H.; Xie, W.; Han, W.; Wang, S.; Huang, X.; Qiu, H.; Li, R. Study on Vibration and Failure of Transverse Flow Turbine Based on Fluid–Structure Interaction. Int. J. Struct. Stab. Dyn. 2026, 26, 2550263. [Google Scholar] [CrossRef] [Scilit]
- Sun, J.; Feng, C.; Zhang, Y.; Zheng, Y. Transient Coupling Modeling and Dynamic Response Analysis of Hydraulic Turbine Governing System and Shafting System. Int. J. Non-Linear Mech. 2024, 160, 104625. [Google Scholar] [CrossRef] [Scilit]
- Zhu, D.; Tao, R.; Xiao, R.; Pan, L. Solving the Runner Blade Crack Problem for a Francis Hydro-Turbine Operating under Condition-Complexity. Renew. Energy 2020, 149, 298–320. [Google Scholar] [CrossRef] [Scilit]
- Zhou, J.; Xu, L.; Zhang, Y.; Zheng, Y.; Li, C.; Zang, W.; Zhang, Z. Analysis of Vortex Evolution in the Stall Region of Pump-Turbines in Pump Mode: Based on Model Testing and CFD. Renew. Energy 2026, 256, 124410. [Google Scholar] [CrossRef] [Scilit]
- Khalfaoui, K.; Bareis, J.; Riedelbauch, S. Scaling of Fluid-Structure Interaction in Hydraulic Turbines Including Fluid-Added Mass Effects. J. Fluids Struct. 2026, 147, 104684. [Google Scholar] [CrossRef] [Scilit]
- Kim, D.; Abdellatef, M.; Leung, C.; Gunawan, B. Two-Way Coupled Fluid-Structure Interaction (FSI) Simulations on a Horizontal-Axis Tidal Current Turbine. Renew. Energy 2026, 268, 125794. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Wang, C.; Wang, S.; Tian, X.; Li, J.; Wang, J. Fluid-Structure Interaction and Modal Analysis of Hydraulic Turbines. J. Phys. Conf. Ser. 2025, 3150, 012047. [Google Scholar] [CrossRef] [Scilit]
- Trivedi, C.; Cervantes, M.J. Fluid-Structure Interactions in Francis Turbines: A Perspective Review. Renew. Sustain. Energy Rev. 2017, 68, 87–101. [Google Scholar] [CrossRef] [Scilit]
- Tong, Z.; Shu, Z.; Liu, D.; Tong, S. Investigating Flow-Induced Vibration in Pump-Turbines Using a Multi-Scale Fluid-Structure Interaction Approach Considering Clearance Flow Effects. Sustain. Energy Technol. Assess. 2025, 82, 104487. [Google Scholar] [CrossRef] [Scilit]
- Bao, W.; Ding, N.; Wang, A.; Hu, J.; Zhang, Y.; Feng, C. Structural Stability and Modal Characteristics of Guide Vanes and Runner in a Pump-Turbine Based on Fluid–Structure Interaction. Water 2026, 18, 2086. [Google Scholar] [CrossRef] [Scilit]
- Li, L.; Yan, D.; Liu, X.; Zhao, W.; Wang, Y.; Pang, J.; Wang, Z. Numerical Study on the Effect of Crown Clearance Thickness on High-Head Pump Turbines. Water 2023, 15, 3397. [Google Scholar] [CrossRef] [Scilit]
- Shi, G.; Hao, Z.; Peng, X.; Wen, X.; Lv, W.; Fu, J. Analysis of Vortex Characteristics in the S-Shaped Region of a Reversible Pump-Turbine with Different Guide Vane Openings Based on Omega Vortex Identification Method. J. Energy Storage 2024, 84, 110921. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.