Abstract
Coal dust carried by open-top freight trains can undergo complex transport and redistribution in confined railway tunnels, where train-induced airflow links in-tunnel particle motion to near-portal dispersion. However, how particle size and source position jointly influence transport across the train–tunnel–portal system remains insufficiently understood. A three-dimensional transient CFD–DPM model was developed for an open-top coal train traveling at 80 km/h through a 200 m local tunnel section and adjoining portal air domains. Four controlled cases combined two prescribed particle sources—a coal-surface source and a near-ground source—with representative diameters of 10 and 350 μm. In the simulated cases, the maximum air speed over the exposed coal surface increased from approximately 24 to 39 m/s during tunnel entry. The 350 μm particles exhibited stronger inertial settling and preferential migration toward the lower tunnel, whereas the 10 μm particles were more strongly coupled to the airflow and transported toward the portal by the train wake. Under the same prescribed source strength, the near-ground-source cases produced higher source-normalized concentration responses than the coal-surface-source cases, indicating a stronger suspended-transport response for particles introduced near the tunnel floor. In the 10 μm near-ground-source case, fine particles passed through the outlet portal and formed a transient elevated plume that spread downstream and laterally. Within the prescribed-input cases examined here, the simulations illustrate the joint influence of particle size and source position on cross-region coal-dust transport and organize the transport pathways into four particle-transport regions: the coal-surface, lower-tunnel, train-wake, and near-portal regions.
1. Introduction
Open-top freight wagons remain widely used for bulk coal transport, but their exposed loads are directly subjected to aerodynamic disturbance during operation. Field measurements along railway corridors have identified coal dust in train-related particulate emissions and increases in PM2.5 associated with coal-train passages [1,2]. Full-scale and wind-tunnel studies have further shown that coal-dust release from wagons depends on near-wagon airflow and shelter configuration [3,4]. These studies establish fugitive coal dust as an environmental and operational concern, but they have largely examined open-line or controlled wind-tunnel conditions. When an open-top coal train enters a railway tunnel, confinement creates a distinct aerodynamic environment that can substantially alter the subsequent transport of particles.
A train entering a tunnel acts as a moving blockage. The air displaced by the train generates pressure waves and piston flow, while the restricted clearance between the train and tunnel wall produces accelerated annular flow [5,6,7]. The resulting slipstream develops around the train body, and the narrow underbody region generates strong near-ground flow. Flow separation around the wagons and the low-pressure wake behind the train further produce recirculation and downstream transport pathways [8,9]. As the train and the accompanying airflow approach the outlet, the tunnel outflow and train wake form a portal jet that expands and mixes with the external atmosphere. These interconnected flow structures determine whether particles migrate toward the lower tunnel, remain suspended in the train wake, or pass through the portal.
Previous studies have addressed several components of this problem. Full-scale measurements and wind-tunnel experiments have quantified coal-dust release from open wagons and evaluated the influence of shelter systems [3,4]. In railway tunnels, engineering studies have documented coal-dust accumulation and the need for specialized removal equipment [10], while in situ measurements have demonstrated that dust loads can affect tunnel facilities and operation [11]. More recently, coal-particle motion during heavy-duty railway-tunnel operation has been investigated directly under carriage–tunnel aerodynamic effects [12]. Collectively, these studies show that wagon-surface release, tunnel dust loading and in-tunnel coal-particle motion have already been examined, although they have generally been treated as separate research questions.
Research in underground railway systems provides additional evidence of the coupling between train-induced airflow and particle motion. Measurements and simulations have shown that piston flow, underbody shear and train wakes can redistribute particles present in confined railway environments [13,14,15]. Recent CFD studies have also examined particulate concentration in underground stations and the transport of tunnel particles toward platform regions under train-induced unsteady flow [16,17]. These studies provide a useful aerodynamic analogy for understanding how train motion can mobilize and transport particles near the tunnel floor. However, subway particles and coal dust differ substantially in their sources, composition, density, morphology and size distributions [18]. Consequently, underground railway studies can support the common airflow–particle interaction mechanism, but their particle properties, source strengths and quantitative transport results cannot be transferred directly to coal dust.
Numerical modeling of train–tunnel airflow and particle transport has also progressed considerably. Sliding- and dynamic-mesh CFD methods have been used to resolve the transient flow around moving trains in tunnels, and comparisons with experimental or on-site measurements have improved understanding of their capabilities and limitations [9,19]. More recent studies have examined tunnel slipstreams, piston flow and wake structures for both high-speed and freight trains using CFD-based analyses [20,21]. CFD particle studies have meanwhile addressed piston-effect-driven transport, particle distribution in underground stations, transport from tunnels to platforms and coal-particle movement during heavy-haul railway operation [12,15,16,17]. Related tunnel-dust and portal-dispersion studies further demonstrate the importance of representing both confined transport and the transition from a tunnel outlet to an external air domain [22,23,24]. This body of work establishes CFD and particle-tracking methods as available research tools; the contribution of the present study therefore lies in its problem formulation and comparative framework rather than in the CFD–DPM method itself.
Despite this progress, the literature remains divided among open-wagon coal-dust release, railway-tunnel dust loading, train-induced particle transport and portal dispersion. Limited attention has been given to a controlled comparison of coal-dust transport from different prescribed source locations within a unified moving-train–railway tunnel–near-portal system. In particular, it remains insufficiently resolved how source position and representative particle size jointly influence the spatial pathway of particles from the train vicinity and lower tunnel, through the train wake, and into the near-portal atmosphere. Addressing this question requires consistent particle inputs and operating conditions so that differences among cases can be attributed to source position and particle size rather than to uncontrolled differences in source strength.
Accordingly, this study develops a three-dimensional transient CFD–DPM model of a loaded open-top coal train traveling at 80 km/h through a 200 m local tunnel section and adjoining near-portal atmospheric domains. Four controlled cases combine two prescribed particle-source locations—a coal-surface source and a near-ground source—with representative particle diameters of 10 and 350 μm under the same prescribed source strength. The analysis examines train-induced airflow, particle trajectories, source-normalized concentration responses and near-portal dispersion, and organizes the resulting pathways into four particle-transport regions: the coal-surface, lower-tunnel, train-wake and near-portal regions. The study contributes a unified framework for comparing the effects of source position and particle size across these connected regions.
2. Materials and Methods
2.1. Study Case, Train-Tunnel Geometry and Computational Domain
We built a three-dimensional train–tunnel–atmosphere model to simulate coal-dust transport during the passage of a loaded open-top coal freight train through a railway tunnel. The computational domain included the moving train, a tunnel section and open atmospheric regions at both portals, allowing in-tunnel transport and near-portal discharge to be analyzed within one model.
The tunnel cross-section was reconstructed from engineering drawings and simplified to maintain the confinement and blockage ratio that control annular flow around the train. The geometry included the features needed to resolve near-wall particle transport and portal-jet development. Although the prototype tunnel extends for several kilometers, this study focuses on the local train–tunnel–atmosphere interaction and near-portal dispersion process. A 200 m straight tunnel section was therefore used as the main tunnel domain. This length allowed the model to capture compression flow ahead of the train, annular acceleration around the train, the tail wake and early particle escape near the outlet portal while keeping the transient simulation computationally feasible [9,25,26,27].
The train geometry was based on a DF8B locomotive and C70 open-top coal wagons. To reduce computational cost while representing the flow structures relevant to dust release and transport, the model used one DF8B locomotive followed by three C70 wagons. The locomotive was 22 m long, and each wagon was 13.976 m long, giving a simplified train length of approximately 64 m. The three wagons were assigned distinct representative roles: the first retained the locomotive-to-wagon flow transition, the second represented repeated open-wagon and inter-wagon interactions, and the third provided the transition from the repeated wagon units to the simplified tail wake. Comparable short-consist arrangements have been used in tunnel-flow, freight-train-aerodynamic and coal-wagon-dust studies [4,28,29]. The exposed coal surfaces were included because they form the primary dust-release region. This configuration represents the main mechanisms considered in the study, including front compression, shear over the exposed coal surface, inter-wagon disturbance, near-ground underbody flow and the low-pressure tail wake. Figure 1 shows the tunnel cross-section, simplified train geometry and two particle-source locations used in the CFD-DPM model.
Figure 1.
Tunnel cross-section, simplified train geometry and particle-source locations: (a) tunnel cross-section; (b) simplified open-top coal train.
Open atmospheric domains were attached to both tunnel portals. A 100 m domain was placed upstream of the tunnel entrance, and a 200 m domain was placed downstream of the tunnel exit. The downstream domain was extended to 200 m to capture the dust-laden portal jet and near-field particle dispersion after the train left the tunnel. The total computational length was 500 m. The lateral width and vertical height of the atmospheric domains were set to ten times the corresponding tunnel cross-sectional dimensions to approximate an open environment near the portals [30]. Figure 2 shows the upstream atmospheric domain, tunnel section, downstream atmospheric domain, boundary conditions and hybrid mesh.
Figure 2.
Computational domain, boundary conditions and hybrid mesh of the train–tunnel–atmosphere system.
Several geometric simplifications were introduced to improve mesh quality and numerical robustness. Small train structures, including lamps, handles, detailed bogie components and minor protrusions, were not resolved. The train surface was smoothed, and the inter-wagon connection was represented by a simplified transition region. Rails, sleepers, cables, signal devices and other auxiliary tunnel facilities were not modeled as separate solids. The track-bed region was represented as a flat ground surface, while the wall boundary treatment accounted for the tunnel-wall effect. These simplifications are commonly adopted in train–tunnel aerodynamic simulations [31,32,33].
2.2. Airflow Model and Moving-Train Treatment
The airflow generated by train passage was solved as the continuous phase in the CFD-DPM framework. The train–tunnel–atmosphere flow was described using a three-dimensional transient Reynolds-averaged Navier–Stokes formulation. Because the baseline train speed was 80 km/h, far below the speed of sound, the airflow was treated as incompressible. The continuous phase was governed by the incompressible continuity and momentum equations:
where u is the air velocity vector, ρ is the air density, p is the static pressure, μeff is the effective dynamic viscosity and Sp is the particle–air momentum source term.
The RANS equations were closed with the standard k–ε model and standard wall functions, which have been widely used in simulations of train-induced unsteady tunnel airflow and regional particle transport [6,13,34,35,36]. The model was used here to represent the unsteady mean pressure and velocity fields and the associated turbulence quantities, thereby providing the continuous-phase background for regional DPM particle transport. Train motion was handled with a dynamic-mesh method, which is commonly used in moving-train–tunnel simulations [9,37]. The train was prescribed as a rigid body translating along the tunnel axis at 80 km/h.
The dynamic mesh was updated with the layering method, which is suitable for rigid-body translation in a straight tunnel [37]. Mesh layers were added or removed near the moving boundary to maintain cell quality during the transient calculation. The upstream and downstream external boundaries were specified as a pressure inlet and a pressure outlet, respectively, both with a gauge pressure of 0 Pa. The train, tunnel wall and ground were treated as no-slip walls, and the air was initially stationary throughout the domain.
Under these conditions, coal-particle transport was driven by train-induced aerodynamic features, including front compression, high-speed annular flow, shear over the exposed coal surface, underbody flow, the train wake and the portal jet after the train leaves the tunnel.
2.3. Discrete-Phase Model and Dust-Source Settings
Coal-dust transport was simulated using a coupled CFD-DPM Eulerian–Lagrangian framework. The airflow was solved in the Eulerian frame, whereas coal-dust particles were tracked as discrete Lagrangian particles. Two-way coupling was adopted so that particle–air momentum exchange was fed back into the continuous-phase momentum equation. Particle–particle collisions were neglected because the particle loading was low.
Particle trajectories were calculated from a force balance [38,39]. Drag and gravity were included because they govern suspension, settling and near-ground transport for the particle sizes considered here. Pressure-gradient, added-mass, Saffman lift and Basset history forces were neglected. The particle motion, drag force and particle Reynolds number were defined as:
where mp, up, dp and ρp are the particle mass, velocity, diameter and density, respectively; u, ρ and μ are the local airflow velocity, air density and dynamic viscosity of air, respectively. FD is the aerodynamic drag force, CD is the drag coefficient, and Rep is the particle Reynolds number.
Particles were assumed to be spherical, with a density of 1400 kg/m3. Two representative particle diameters were used: 350 μm and 10 μm. The 350 μm particles represented inertia- and settling-dominated transport, whereas the 10 μm particles represented suspension-dominated transport [38,40,41]. Turbulent dispersion was represented using the discrete random walk model [42].
As shown in Figure 1b, two prescribed surface-injection sources were defined: a coal-surface source on the exposed coal surface and a near-ground source near the tunnel floor. In each case, the active source used a prescribed mass flow rate of 6.0 × 10−4 kg/s [3,4] from t = 0 to t = 13 s; after injection ceased, particles already present in the domain continued to be tracked. The flattened track-bed and tunnel-floor surfaces were assigned the trap condition, whereas the tunnel sidewalls, ceiling and rigid train surfaces were assigned the reflect condition. Open external boundaries were assigned the escape condition, and particles passed continuously through internal fluid interfaces.
In the global stationary reference frame, the coal-surface source moved with the train. The initial particle velocity was therefore set to 22.22 m/s in the tunnel-axis direction, with both the lateral and vertical components set to 0 m/s. The near-ground source remained stationary relative to the tunnel, and its initial particle velocity was set to 0 m/s in all three directions.
Computational parcels were generated from active particle streams defined by the mesh discretization of each injection surface. No fixed total number of parcels was prescribed; each active stream generated one computational parcel at every continuous-phase time step.
Four cases were defined by combining the two particle diameters with the two prescribed source locations (Table 1). The same source strength was used in all cases to isolate the effects of particle size and source position. A source-normalized concentration response was then introduced to compare the relative suspended-particle responses among the four prescribed-input cases:
where η is the source-normalized concentration response, C is the area-weighted mean particle concentration at a selected monitoring section and is the particle mass flow rate of the corresponding source.
Table 1.
Particle-source settings and simulation cases.
The entrance and outlet monitoring sections used to evaluate the source-normalized concentration response were each located 1 m inside the tunnel from the corresponding portal. At each data-output instant, C was calculated as the area-weighted mean particle mass concentration over the fluid region of the corresponding section.
2.4. Mesh and Numerical Settings
A hybrid mesh was generated for the train–tunnel–atmosphere domain. Polyhedral cells were used in the external atmospheric regions to improve mesh orthogonality and reduce the far-field cell count. Structured cells were used in the tunnel core and train-motion regions because they are compatible with the layering-based dynamic-mesh update. Around the train body, unstructured cells were generated to fit the locomotive surface, open-top wagons, and inter-wagon geometry.
Local refinement was applied around the train body, wagon cavities, exposed coal surfaces, underbody region, and tunnel portals. Cell sizes of 0.05–0.20 m were used in the wagon cavities and near the exposed coal surfaces. Ten prism layers were generated near the wagon walls, exposed coal surfaces, and tunnel walls, with a representative y+ value of 50. The selected mesh contained approximately 1.04 million cells, with a maximum skewness of 0.8 and a minimum orthogonal quality of 0.128. In the dynamic-mesh region, the split and collapse factors for the layering method were set to 0.4 and 0.2, respectively.
Grid and time-step sensitivity tests were conducted using meshes containing approximately 0.81, 1.04, and 1.56 million cells and time steps of 0.02, 0.01, and 0.005 s. Grid sensitivity was evaluated using the time history of the cross-sectional mean velocity at the tunnel entrance. The maximum relative deviation between the 1.04- and 1.56-million-cell meshes was 2.51%. Time-step sensitivity was evaluated using the pressure and velocity recorded at a fixed monitoring point near the tunnel entrance, located on the tunnel centerline and 1 m below the crown. The three time steps produced consistent overall trends and peak timings. Accordingly, the 1.04-million-cell mesh and a time step of 0.02 s were adopted for the subsequent simulations.
The simulations were performed in ANSYS Fluent 2024 R2 using a pressure-based three-dimensional transient solver. Pressure–velocity coupling was handled using the SIMPLE algorithm. Momentum, turbulent kinetic energy, and turbulent dissipation rate were discretized using second-order upwind schemes, while the transient term was discretized using a second-order implicit scheme. A maximum of 200 iterations was allowed per time step, and normalized residuals below 10−3 for the continuity, momentum, and turbulence equations were used as the convergence criterion.
3. Results and Discussion
3.1. Evolution of Train-Induced Airflow
Train-induced airflow governs the downstream transport of coal-dust particles after they enter the flow; therefore, the airflow field is analyzed before the particle results. Under the 80 km/h baseline condition, the open-top coal train acted as a moving blockage in the confined tunnel. The entering train accelerated the initially still air and produced a coupled flow field around the locomotive, wagons, underbody region, wake and outlet portal. The time-resolved velocity fields in Figure 3 show three stages. During tunnel entry, the effective flow area decreased rapidly after the train nose entered the portal, and strong acceleration developed in the narrow gaps between the train and the tunnel wall. During mid-tunnel running, continuous high-speed bands formed above, beside and beneath the train. During tunnel exit, high-momentum airflow moved toward the outlet portal, where the portal jet and train wake formed the downstream transport path for suspended fine particles.
Figure 3.
Velocity-field evolution during train passage: (a) tunnel entry; (b) mid-tunnel running; (c) tunnel exit.
The cross-sectional velocity vectors in Figure 4 further show the local flow structures that drive dust movement. Around the open-top wagons, the outer high-speed flow separated at the wagon edges and interacted with the wagon cavities, allowing air to enter the region above the exposed coal surface. Beneath the train, the underbody flow accelerated through the narrow ground clearance. Behind the train, the wake formed a recirculating low-pressure region that could collect particles entering the airflow from both prescribed source locations.
Figure 4.
Cross-sectional velocity vectors during train passage: (a) tunnel entry; (b) mid-tunnel running; (c) tunnel exit. The red boxes mark the corresponding local regions, and the arrow in (a) indicates the associated enlarged view.
The air-speed field over the exposed coal surfaces was strongly non-uniform. Figure 5 shows local high-speed zones near wagon edges, inter-wagon regions and windward areas of the exposed coal surface. These locations were associated with locally enhanced aerodynamic disturbance over the exposed coal surface.
Figure 5.
Air-speed distribution over the exposed coal surfaces during tunnel entry with the train nose (a) 25 m; (b) 38 m; (c) 54 m; and (d) 66 m inside the tunnel. The shaded region represents the tunnel-entrance wall.
Figure 6 shows that aerodynamic forcing on the exposed coal surfaces was highly transient. The maximum air speed rose from approximately 24 m/s to nearly 39 m/s during tunnel entry and reached its highest value during the early tunnel-entry stage. This entrance-stage peak indicates enhanced aerodynamic disturbance near the exposed coal surface and conditions potentially favorable for coal-dust release.
Figure 6.
The temporal variation in maximum air speed over the exposed coal surfaces.
Overall, the airflow results identify three characteristic flow features relevant to particle transport: the high-speed shear zone above the exposed coal surface, the near-ground underbody-flow zone and the train-wake/portal-jet transport zone. These flow features provide the aerodynamic basis for the particle-transport patterns analyzed below.
3.2. Effects of Particle Diameter on Coal-Dust Transport and Deposition
Particle diameter strongly influenced whether the prescribed coal-dust particles remained airborne or deposited. Figure 7 compares the three-dimensional trajectories under the four source-location and particle-size settings. The 350 μm particles were dominated by inertia and gravitational settling. In the W-350 case, only part of the prescribed particles entered the shear layer above the wagon, whereas much of the material settled toward the lower-tunnel region. In the G-350 case, underbody flow and wake suction lifted particles locally, but deposition near the floor remained evident. By contrast, 10 μm particles followed the airflow more closely. In both source locations, they were carried by the wagon shear layer, underbody flow and train wake over longer distances and were therefore more readily transported toward the outlet portal.
Figure 7.
Three-dimensional coal-dust trajectories under four source-location and particle-size settings: (a) W-350; (b) W-10; (c) G-350; and (d) G-10. W and G denote the coal-surface and near-ground sources, respectively; 350 and 10 denote particle diameters in μm.
Figure 8 and Figure 9 show how particle diameter and source location shaped the suspended concentration field. In Figure 8, particle size mainly affected the vertical spread of the particle cloud, whereas source location affected the strength and continuity of the suspended response. Cases with the coal-surface source remained localized around the train and the lower tunnel. Cases with the near-ground source formed more continuous near-ground concentration bands because particles injected near the tunnel floor were exposed directly to underbody shear and wake suction. Figure 9 further shows how the G-10 case developed into a mobile suspended plume: fine particles injected from the near-ground source were stretched downstream along the lower tunnel by the train wake and transported toward the outlet. This sequence links the prescribed near-ground particle input with downstream suspended transport. The corresponding particle mass balance at the train-exit time (t = 13 s) is summarized in Table 2.
Figure 8.
Airborne coal-dust concentration (kg/m3) on the longitudinal centerline section with the train at the tunnel midsection: (a) W-350; (b) W-10; (c) G-350; and (d) G-10.
Figure 9.
The temporal evolution of airborne coal-dust concentration in the G-10 case: (a–f) six successive stages as the train travels from the tunnel entrance toward the outlet.
Table 2.
The particle mass balance for the four prescribed-source cases at the train-exit time (t = 13 s).
3.3. Effects of Prescribed Source Location on the Source-Normalized Concentration Response
In addition to particle diameter, the prescribed source location influenced the entrainment pathway and the source-normalized concentration response. As shown in Figure 10, the near-ground-source curves are markedly higher than the coal-surface-source curves at both the entrance and exit sections. Under the same prescribed source strength, particles introduced near the tunnel floor therefore produced a stronger suspended concentration response than those introduced from the coal surface.
Figure 10.
The source-normalized airborne coal-dust concentration response at the tunnel entrance and exit: (a) entrance section; (b) exit section.
This difference can be attributed to the distinct aerodynamic pathways identified in the previous sections. Particles introduced from the prescribed coal-surface source first entered the shear layer above the wagons, and much of the coarse material settled before contributing to the suspended concentration at the monitoring sections. By contrast, particles introduced from the prescribed near-ground source entered the underbody-flow and wake regions more directly, where near-ground shear and local vortices enhanced particle redistribution and downstream transport. These contrasting pathways explain the stronger source-normalized response of the near-ground-source cases under the same prescribed input.
These findings suggest two potential directions for future dust-control assessment. Reducing wagon-surface release may limit the amount of material initially entering the tunnel. Where lower-tunnel deposits are present, removing or stabilizing them may reduce the material available for subsequent resuspension during repeated train passages. This longer-term implication represents a plausible extension of the single-passage transport pattern and warrants further verification under repeated-operation conditions.
3.4. Portal Discharge and Near-Field Dispersion
Portal discharge connects in-tunnel particle transport with near-portal dispersion. Under the present condition, with no imposed ambient wind, suspended particles were carried into the external domain by the train wake and portal outflow as the train exited the tunnel. After leaving the confined section, the particle-laden flow expanded and mixed with the surrounding air. In the G-10 case shown in Figure 11, fine particles introduced from the prescribed near-ground source passed through the outlet portal and formed a transient elevated plume. In the longitudinal centerline section, the plume remained suspended above the ground, whereas the plan view shows that it extended primarily along the tunnel axis and broadened laterally downstream.
Figure 11.
The coal-dust concentration distribution in the G-10 case: (a) longitudinal centerline section; (b) top view.
Figure 12 shows a different near-portal transport pattern for 350 μm particles. In the G-350 case, particles also passed beyond the portal in plan view, but their vertical distribution remained concentrated near the ground and did not form the elevated plume observed in the G-10 case. Thus, under the same prescribed source strength and boundary conditions, particle diameter affected the vertical structure of near-portal transport: 10 μm particles remained more strongly coupled to the airflow, whereas 350 μm particles exhibited stronger near-ground transport and settling behavior.
Figure 12.
Spatial concentration distributions for 350 μm particles: (a) W-350; (b) G-350.
The simulated portal-discharge process can be summarized in three stages. First, particles introduced from the prescribed coal-surface or near-ground sources were transported toward the outlet by the train-induced flow and wake. Second, suspended particles passed through the portal with the exiting airflow. Third, the outflow expanded and mixed with the external air, producing particle-size-dependent near-portal concentration patterns. This sequence shows how in-tunnel particle transport can extend into the adjoining external domain under the present modeled condition.
Taken together, the outlet portal represents a transition from confined, wake-driven particle transport inside the tunnel to near-field dispersion in the external domain. The contrast between the G-10 and G-350 cases further shows that particle diameter influences the vertical structure of this transition: the 10 μm particles formed an elevated suspended plume, whereas the 350 μm particles were concentrated closer to the ground.
3.5. Particle-Transport Regions
The preceding results show that coal-dust transport develops across a sequence of spatial regions rather than being confined to a single high-concentration location. Particles introduced near the exposed coal surface are first subjected to strong aerodynamic disturbances during tunnel entry and are subsequently transported toward the lower tunnel or entrained into the train wake. Fine particles that remain suspended can then be carried toward and through the outlet portal. Based on these transport characteristics, the results can be organized into four particle-transport regions: the coal-surface region, the lower-tunnel region, the train-wake region and the near-portal region.
The coal-surface region comprises the exposed coal surfaces and the airspace within and immediately above the open-top wagon cavities. In this region, the high-speed accompanying flow, wagon-edge separation and wagon-cavity recirculation produced strong aerodynamic disturbances over the coal beds. Figure 5 and Figure 6 show that the aerodynamic loading in this region was strongest during tunnel entry, when the maximum air speed over the exposed coal surface increased from approximately 24 to nearly 39 m/s. These flow structures intensified the aerodynamic disturbance over the exposed coal surface and influenced the initial transport of particles introduced from the prescribed coal-surface source.
The lower-tunnel region includes the track-bed vicinity, tunnel floor, lower walls and other lower parts of the tunnel around and beneath the train. This region received coarse particles that migrated downward from the coal-surface-source cases because of their stronger inertia and gravitational settling. It also represents the initial location of particles introduced from the prescribed near-ground source. The particle trajectories, concentration fields and source-normalized concentration responses show that near-ground-source particles were directly affected by the underbody flow and train wake and produced a stronger suspended-transport response than coal-surface-source particles under the same prescribed source strength.
The train-wake region is located behind the moving train. Wake vortices, recirculating flow and turbulent dispersion entrained and redistributed particles introduced from both prescribed source locations. However, the 10 μm particles followed the airflow more closely than the 350 μm particles and were therefore more likely to remain suspended and move downstream. This behavior was particularly evident in the G-10 temporal sequence, in which fine particles introduced near the tunnel floor were stretched downstream by the underbody flow and train wake and progressively transported toward the outlet. The train-wake region therefore connects particle transport around the coal surface and lower tunnel with downstream suspended transport.
The near-portal region is located at the outlet portal and in the adjoining external air domain, marking the transition from confined in-tunnel transport to external near-field dispersion. The G-10 results show that fine particles introduced from the prescribed near-ground source passed through the outlet portal and formed a transient elevated plume that spread downstream and laterally. By contrast, although the G-350 particles also passed beyond the portal in plan view, their vertical distribution remained concentrated closer to the ground. The near-portal region therefore exhibited particle-size-dependent transport characteristics: fine particles formed an elevated suspended plume, whereas coarse particles showed stronger near-ground transport and settling tendencies.
The main characteristics and representative results of the four particle-transport regions are summarized in Table 3.
Table 3.
The characteristics and representative results of the four particle-transport regions.
3.6. Engineering Insights and Study Limitations
Taken together, the particle-size and source-location comparisons suggest a plausible time-lagged transport pathway under repeated train operation. During a single passage, coarse particles showed preferential migration toward the lower tunnel, whereas fine particles introduced near the tunnel floor were readily carried downstream by the underbody flow and train wake. Over repeated passages, continued deposition could gradually increase the amount of particulate material stored in the lower tunnel. If part of this material is disturbed during subsequent operations and becomes airborne, the near-ground-source results indicate a plausible route by which fine particles could enter the wake-transport pathway and ultimately reach the near-portal region. This mechanism-based interpretation extends the single-passage findings to repeated operation and should be examined further through multi-passage simulations and long-term field observations.
The simulated transport pathways suggest that future site-specific dust-control assessments could consider the entire transport chain rather than focusing only on visible plumes near the portal. The strong aerodynamic disturbance during tunnel entry highlights the exposed coal surface and pre-entry wagon condition as priorities for inspection and for evaluating surface dust-suppression practices. The downward migration of coarse particles identifies the track-bed vicinity, tunnel floor and lower walls as important locations for deposit inspection, cleaning or stabilization. Because fine particles entering near the tunnel floor can be transported downstream by the underbody flow and wake, local ventilation, flow interception and mist-based control may warrant evaluation along the wake-transport pathway. Near the outlet portal, the contrasting vertical distributions of fine and coarse particles indicate that monitoring and potential interception measures should consider both particle size and sampling height. These measures represent candidate intervention directions derived from the simulated transport pathways, and their practical configurations and operating parameters require site-specific evaluation.
The four particle cases were simulated using the same geometry, train speed, boundary conditions and prescribed particle mass flow rate, providing a controlled basis for comparing the relative effects of particle diameter and source location. The model is therefore most suitable for interpreting differences in transport pathways, spatial distributions, settling tendencies and source-normalized concentration responses under a common aerodynamic background. The prescribed particle inputs are comparative source conditions rather than field-calibrated emission or resuspension rates, and the two particle diameters represent contrasting coarse- and fine-particle behaviors rather than a continuous particle-size distribution. Accordingly, the present findings are best interpreted as a relative comparison for a single train passage at 80 km/h under conditions with no imposed ambient wind, rather than as a speed-response, repeated-operation or mitigation-performance assessment.
The grid- and time-step-sensitivity analyses and convergence checks support the numerical consistency of the present calculations. However, matching experimental or field data are not yet available for quantitative physical validation; consequently, the absolute airflow velocities, particle concentrations, deposition amounts and near-portal dispersion scales should be interpreted with caution, whereas the relative differences among cases provide a stronger basis for the present discussion. In addition, the 200 m local tunnel section, shortened consist of one locomotive and three wagons, simplified flat track bed and standard k–ε model focus the analysis on local train–tunnel–portal interactions. These settings do not fully reproduce the longitudinal development in a several-kilometer tunnel; the cumulative aerodynamic effects of a long freight consist; detailed deposition around rails, sleepers and ballast; or fine-scale unsteady turbulent structures. Future work should combine field monitoring or scaled experiments with multi-speed, longer-consist and repeated-passage simulations, and should further examine realistic particle-source processes, continuous particle-size distributions, different ambient-wind conditions and the performance of the proposed intervention measures.
4. Conclusions
This study used a three-dimensional transient CFD–DPM model to investigate the transport, settling and near-portal dispersion of coal-dust particles introduced from prescribed sources within a train–tunnel–portal system. Four controlled cases were defined by combining two prescribed source locations—the exposed coal surface and the near-ground region—with two representative particle diameters of 10 and 350 μm. The main conclusions are as follows.
- (1)
- Under the simulated conditions, tunnel entry produced the strongest aerodynamic disturbance over the exposed coal surface. The maximum surface air speed increased from approximately 24 to 39 m/s, corresponding to an increase of approximately 15 m/s, or about 63% relative to the pre-entry level. The tunnel-entry stage therefore represented the period of strongest aerodynamic loading on the exposed coal surface.
- (2)
- Particle diameter strongly controlled the balance between suspension and downward migration. The 350 μm particles were more strongly affected by inertia and gravitational settling and preferentially migrated downward, exhibiting more pronounced near-ground transport and deposition. By contrast, the 10 μm particles were more strongly coupled to the airflow and were more readily carried over longer distances toward the outlet portal by the wagon shear layer, underbody flow and train wake.
- (3)
- Source location affected the suspended concentration response under the controlled source conditions. With the same prescribed particle mass flow rate, the near-ground-source cases produced higher source-normalized concentration responses than the coal-surface-source cases. This result indicates that particles introduced near the tunnel floor were more readily entrained into the airflow and transported in suspension by the underbody flow and train wake. This comparison therefore reflects differences in transport response under equal prescribed inputs rather than the relative contributions of actual coal-surface release and near-ground resuspension.
- (4)
- Particle diameter also controlled the vertical structure of near-portal dispersion. With no ambient wind imposed, the 10 μm particles introduced from the near-ground source passed through the outlet portal and formed a transient elevated plume that spread downstream and laterally. Although the 350 μm near-ground-source particles were also transported beyond the portal, their vertical distribution remained concentrated closer to the ground. Fine and coarse particles therefore exhibited distinct vertical dispersion patterns near the outlet portal.
- (5)
- The simulated results were synthesized into four particle-transport regions defined by their locations and dominant transport behaviors: the coal-surface region, the lower-tunnel region, the train-wake region and the near-portal region. The tendency of coarse particles to migrate toward the lower tunnel, together with the wake-driven transport of near-ground fine particles, suggests a plausible time-lagged pathway under repeated operation, in which deposited material may later re-enter the airflow if disturbed. This spatial framework may help organize candidate monitoring locations and dust-control options for subsequent site-specific evaluation.
The present findings primarily support relative comparisons of particle-transport pathways and spatial responses among the four prescribed-source cases under the investigated conditions. Their quantitative extension to field-scale emission and resuspension rates, repeated-passage scenarios and other train–tunnel configurations requires further validation.
Author Contributions
Conceptualization, S.C. and X.W.; methodology, S.C.; software, S.C.; validation, S.C. and Y.Z.; formal analysis, S.C.; investigation, S.C., Y.Z., H.G. and C.Y.; resources, Y.Z., H.G., C.Y. and X.W.; data curation, S.C. and Y.Z.; writing—original draft preparation, S.C.; writing—review and editing, Y.Z., H.G., C.Y. and X.W.; visualization, S.C.; supervision, X.W.; project administration, X.W.; funding acquisition, X.W. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Science and Technology Research and Development Program of China Railway Xi’an Group Co., Ltd., grant number XA-JGBM-JT-JNHBK-20250002.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The raw data supporting the conclusions of this article are available from the corresponding author upon reasonable request.
Conflicts of Interest
Yi Zhang, Haoyao Gui and Chuncheng Yu are employed by China Railway Xi’an Group Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
- Jaffe, D.; Putz, J.; Hof, G.; Hof, G.; Hee, J.; Lommers-Johnson, D.A.; Gabela, F.; Fry, J.L.; Ayres, B.; Kelp, M.; et al. Diesel Particulate Matter and Coal Dust from Trains in the Columbia River Gorge, Washington State, USA. Atmos. Pollut. Res. 2015, 6, 946–952. [Google Scholar] [CrossRef] [Scilit]
- Ostro, B.; Spada, N.; Kuiper, H. The Impact of Coal Trains on PM2.5 in the San Francisco Bay Area. Air Qual. Atmos. Health 2023, 16, 1173–1183. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ferreira, A.D.; Viegas, D.X.; Sousa, A.C.M. Full-Scale Measurements for Evaluation of Coal Dust Release from Train Wagons with Two Different Shelter Covers. J. Wind Eng. Ind. Aerodyn. 2003, 91, 1271–1283. [Google Scholar] [CrossRef] [Scilit]
- Ferreira, A.D.; Vaz, P.A. Wind Tunnel Study of Coal Dust Release from Train Wagons. J. Wind Eng. Ind. Aerodyn. 2004, 92, 565–577. [Google Scholar] [CrossRef] [Scilit][Green Version]
- Baker, C.J. A Review of Train Aerodynamics Part 1—Fundamentals. Aeronaut. J. 2014, 118, 201–228. [Google Scholar] [CrossRef] [Scilit]
- Kim, J.Y.; Kim, K.Y. Experimental and Numerical Analyses of Train-Induced Unsteady Tunnel Flow in Subway. Tunn. Undergr. Space Technol. 2007, 22, 166–172. [Google Scholar] [CrossRef] [Scilit]
- Cross, D.; Hughes, B.; Ingham, D.; Ma, L. A Validated Numerical Investigation of the Effects of High Blockage Ratio and Train and Tunnel Length upon Underground Railway Aerodynamics. J. Wind Eng. Ind. Aerodyn. 2015, 146, 195–206. [Google Scholar] [CrossRef] [Scilit]
- Jiang, Z.; Liu, T.; Chen, X.; Li, W.; Guo, Z.; Niu, J. Numerical Prediction of the Slipstream Caused by the Trains with Different Marshalling Forms Entering a Tunnel. J. Wind Eng. Ind. Aerodyn. 2019, 189, 276–288. [Google Scholar] [CrossRef] [Scilit]
- Iliadis, P.; Hemida, H.; Soper, D.; Baker, C. Numerical Simulations of the Separated Flow around a Freight Train Passing through a Tunnel Using the Sliding Mesh Technique. Proc. Inst. Mech. Eng. Part F J. Rail Rapid Transit 2020, 234, 638–654. [Google Scholar] [CrossRef] [Scilit]
- Li, Y.; Meng, Z. Design and Implementation of a Coal-Dust Removal Device for Heavy-Haul Railway Tunnels. Transp. Saf. Environ. 2020, 2, 283–291. [Google Scholar] [CrossRef] [Scilit]
- Sturm, P.; Fruhwirt, D.; Steiner, H. Impact of Dust Loads in Long Railway Tunnels: In-Situ Measurements and Consequences for Tunnel Facilities and Operation. Tunn. Undergr. Space Technol. 2022, 122, 104328. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Z.; Luo, J.; He, B.; Mao, L.; Liu, H.; Wang, G.; Wang, L.; Yan, G. Study on Coal Particle Movement during Heavy-Duty Railway Tunnel Operation: Based on Carriage-Tunnel Aerodynamic Effect. Process Saf. Environ. Prot. 2026, 213, 108940. [Google Scholar] [CrossRef] [Scilit]
- Lee, K.-R.; Kim, W.-G.; Woo, S.-H.; Kim, J.B.; Bae, G.-N.; Park, H.-K.; Yoon, H.H.; Yook, S.-J. Investigation of Airflow and Particle Behavior around a Subway Train Running in the Underground Tunnel. Aerosol Sci. Technol. 2016, 50, 669–678. [Google Scholar] [CrossRef] [Scilit]
- Woo, S.-H.; Kim, J.B.; Bae, G.-N.; Hwang, M.S.; Tahk, G.H.; Yoon, H.H.; Yook, S.-J. Investigation of Diurnal Pattern of Generation and Resuspension of Particles Induced by Moving Subway Trains in an Underground Tunnel. Aerosol Air Qual. Res. 2018, 18, 2240–2252. [Google Scholar] [CrossRef] [Scilit]
- Izadi, T.; Mehrabian, M.A.; Ahmadi, G.; Abouali, O. Numerical Analysis of the Mirco-Particles Distribution inside an Underground Subway System Due to Train Piston Effect. J. Wind Eng. Ind. Aerodyn. 2021, 211, 104533. [Google Scholar] [CrossRef] [Scilit]
- Yang, J.; Liu, M.; Zhang, H.; Zheng, W.; Ye, T. Numerical Analysis and Improvement Strategy of Particulate Matter Concentration in Underground Subway Stations. Tunn. Undergr. Space Technol. 2024, 146, 105662. [Google Scholar] [CrossRef] [Scilit]
- Yang, J.; Zhang, H.; Fan, X.; Wan, Z.; Wang, Z.; Zheng, W. A Computational Fluid Dynamics Approach for Predicting the Transportation of Subway Tunnel Particles to Platform in Train Movement-Induced Unsteady Fluid Flow. Phys. Fluids 2026, 38, 073324. [Google Scholar] [CrossRef] [Scilit]
- Loxham, M.; Nieuwenhuijsen, M.J. Health Effects of Particulate Matter Air Pollution in Underground Railway Systems—A Critical Review of the Evidence. Part. Fibre Toxicol. 2019, 16, 12. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Faugier, L.; Marinus, B.G.; Bosschaerts, W.; Laboureur, D.; Limam, K. CFD Model for Airflow in a Subway Station Compared to On-Site Measurements: The Challenges of as-Built Environment. Tunn. Undergr. Space Technol. 2023, 140, 105248. [Google Scholar] [CrossRef] [Scilit]
- Negri, S.; Tomasini, G.; Rocchi, D.; Schito, P.; Soper, D.; Hemida, H. Numerical Assessment of Train Slipstream in Tunnels: Stochastic Analysis from CFD Data. J. Wind Eng. Ind. Aerodyn. 2025, 264, 106130. [Google Scholar] [CrossRef] [Scilit]
- Negri, S.; Tomasini, G.; Araya Reyes, C.E.; Rocchi, D. CFD Analysis of Flow Patterns Induced by High-Speed and Freight Trains in Tunnels and Their Impact on Platform Regions. Int. J. Rail Transp. 2026, 1–23. [Google Scholar] [CrossRef] [Scilit]
- Liu, Q.; Nie, W.; Hua, Y.; Peng, H.; Liu, C.; Wei, C. Research on Tunnel Ventilation Systems: Dust Diffusion and Pollution Behaviour by Air Curtains Based on CFD Technology and Field Measurement. Build. Environ. 2019, 147, 444–460. [Google Scholar] [CrossRef] [Scilit]
- Oettl, D.; Sturm, P.J.; Bacher, M.; Pretterhofer, G.; Almbauer, R.A. A Simple Model for the Dispersion of Pollutants from a Road Tunnel Portal. Atmos. Environ. 2002, 36, 2943–2953. [Google Scholar] [CrossRef] [Scilit]
- Dong, J.; Tao, Y.; Xiao, Y.; Tu, J. Numerical Simulation of Pollutant Dispersion in Urban Roadway Tunnels. J. Comput. Multiph. Flows 2017, 9, 26–31. [Google Scholar] [CrossRef] [Scilit]
- Faugier, L.; Marinus, B.G.; Bosschaerts, W.; Laboureur, D.; Limam, K. CFD Model to Assess Parameters Influencing Piston Wind in a Subway Tunnel and Station. J. Phys. Conf. Ser. 2021, 2042, 012076. [Google Scholar] [CrossRef] [Scilit]
- Yang, W.; Deng, E.; Zhu, Z.; He, X.; Wang, Y. Deterioration of Dynamic Response during High-Speed Train Travelling in Tunnel–Bridge–Tunnel Scenario under Crosswinds. Tunn. Undergr. Space Technol. 2020, 106, 103627. [Google Scholar] [CrossRef] [Scilit]
- Zhou, L.; Liu, T.; Chen, Z.; Li, W.; Guo, Z.; He, X.; Wang, Y. Comparison Study of the Effect of Bridge-Tunnel Transition on Train Aerodynamic Performance with or without Crosswind. Wind Struct. 2021, 32, 597–612. [Google Scholar] [CrossRef]
- Li, L.; Li, X.; Jin, K.; Yang, X.; Xu, L.; Niu, J. Numerical Study on the Indoor Flow Field and Ventilation Performance in the Power Room of a Hybrid Locomotive That Passes through a Tunnel. Tunn. Undergr. Space Technol. 2023, 141, 105379. [Google Scholar] [CrossRef] [Scilit]
- Corniani, L.; Schito, P.; Bell, J.; Pombo, J.; Bruni, S. Aerodynamics of Freight Trains—Addressing the Complexity of Train Geometry through an Open Database. Promet—Traffic Transp. 2026, 38, 58–70. [Google Scholar] [CrossRef] [Scilit]
- Blocken, B. Computational Fluid Dynamics for Urban Physics: Importance, Scales, Possibilities, Limitations and Ten Tips and Tricks towards Accurate and Reliable Simulations. Build. Environ. 2015, 91, 219–245. [Google Scholar] [CrossRef] [Scilit]
- Yang, X.; Okajima, A.; Kiwata, T.; Ohtuyama, S. Numerical Analysis of Unsteady Compressible Turbulent Flows About a Train Passing Through a Tunnel; SAE Technical Paper 1999-01-0804; SAE International: Warrendale, PA, USA, 1999. [Google Scholar] [CrossRef] [Scilit]
- Dong, T.; Liang, X.; Krajnović, S.; Xiong, X.; Zhou, W. Effects of Simplifying Train Bogies on Surrounding Flow and Aerodynamic Forces. J. Wind Eng. Ind. Aerodyn. 2019, 191, 170–182. [Google Scholar] [CrossRef] [Scilit]
- Ren, C.; Feng, Z.; Cen, D.; Cao, S.-J. Study on the Subway Environment Induced by Moving Train Using Gaussian Distributed Momentum Source Theory Method. Indoor Built Environ. 2019, 28, 1083–1091. [Google Scholar] [CrossRef] [Scilit]
- Launder, B.E.; Spalding, D.B. The Numerical Computation of Turbulent Flows. Comput. Methods Appl. Mech. Eng. 1974, 3, 269–289. [Google Scholar] [CrossRef] [Scilit]
- Meng, H.; Li, N.; Shen, X.; Zhang, H.; Li, T. Numerical Analysis of Urban-Rail Vehicle/Tunnel Aerodynamic Interaction. Fluid Dyn. Mater. Process. 2025, 21, 161–178. [Google Scholar] [CrossRef] [Scilit]
- Peng, Y.; Gao, Z.; Ding, W.; Zhang, J.; Li, X.; Xu, J.; Wei, Y. Application of Computational Fluid Dynamics in Subway Environment without Fire and Smoke—Literature Review. Build. Environ. 2021, 206, 108408. [Google Scholar] [CrossRef] [Scilit]
- López González, M.; Galdo Vega, M.; Fernández Oro, J.M.; Blanco Marigorta, E. Numerical Modeling of the Piston Effect in Longitudinal Ventilation Systems for Subway Tunnels. Tunn. Undergr. Space Technol. 2014, 40, 22–37. [Google Scholar] [CrossRef] [Scilit]
- Maxey, M.R.; Riley, J.J. Equation of Motion for a Small Rigid Sphere in a Nonuniform Flow. Phys. Fluids 1983, 26, 883–889. [Google Scholar] [CrossRef] [Scilit]
- Morsi, S.A.; Alexander, A.J. An Investigation of Particle Trajectories in Two-Phase Flow Systems. J. Fluid Mech. 1972, 55, 193–208. [Google Scholar] [CrossRef] [Scilit]
- Abbasi, B.; Wang, X.; Chow, J.C.; Watson, J.G.; Peik, B.; Nasiri, V.; Riemenschnitter, K.B.; Elahifard, M. Review of Respirable Coal Mine Dust Characterization for Mass Concentration, Size Distribution and Chemical Composition. Minerals 2021, 11, 426. [Google Scholar] [CrossRef] [Scilit]
- Walther, E.; Bogdan, M.; Cohen, R. Modelling of Airborne Particulate Matter Concentration in Underground Stations Using a Two Size-Class Conservation Model. Sci. Total Environ. 2017, 607–608, 1313–1319. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mofakham, A.A.; Ahmadi, G. On Random Walk Models for Simulation of Particle-Laden Turbulent Flows. Int. J. Multiph. Flow 2020, 122, 103157. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.