Skip to Content
CancersCancers
  • Article
  • Open Access

31 March 2026

21 Pages

Machine Learning-Based Fluorescence Assessment for Augmented Imaging and Decision Support in Glioblastoma Resections

,
,
,
,
,
,
and
1
Department of Neurosurgery, Faculty of Medicine, Otto-von-Guericke University Magdeburg, Leipziger Strasse 44, 39120 Magdeburg, Germany
2
INKA Health Tech Innovation Laboratory, Medical Faculty, Otto-von-Guericke University Magdeburg, Leipziger Strasse 44, 39120 Magdeburg, Germany
*
Author to whom correspondence should be addressed.

Simple Summary

Glioblastoma is a highly aggressive brain tumor characterized by infiltrative growth, making complete surgical removal challenging without compromising critical brain functions. During surgery, 5-ALA fluorescence is commonly used to visualize tumor tissue; however, weak or ambiguous signals can limit its reliability. In this study, we developed a machine learning approach to enhance fluorescence detection in standard surgical microscope images. The proposed model analyzes images at the pixel level and is capable of identifying subtle fluorescence signals that may not be visible to the human eye. Experiments on synthetic data and real intraoperative images demonstrated that the method detects larger tumor-associated regions while maintaining very high specificity. In addition, a separate regression model was used to estimate PPIX-related fluorescence intensity in synthetic samples. Overall, this approach may support surgeons with more objective information, contributing to improved tumor resection while preserving healthy brain tissue.

Abstract

Background/Objectives: Glioblastoma is the most common and aggressive primary malignant brain tumor in adults, characterized by infiltrative growth and poor prognosis. Achieving maximal resection without inducing neurological deficits remains a challenge in glioblastoma surgery. While 5-aminolevulinic acid-based fluorescence-guided surgery supports intraoperative tumor visualization, its reliability is limited by patient variability and weak fluorescence signals. This study proposes a machine learning framework to enhance fluorescence-guided surgery sensitivity by analyzing surgical microscope images at the pixel level. Methods: Fluorescence-mode neurosurgical microscope images of synthetic samples with known Protoporphyrin IX (PPIX) concentrations were used to train three classifiers (Support Vector Machine, Naïve Bayes, Neural Network) for pixel-wise fluorescence detection. In parallel, three contrastive-learning-based Variational Autoencoders (VAE, β = 1, 2, 3) were evaluated for detecting weak fluorescence beyond visual perception. Additionally, a regression model was trained to relate pixel features to PPIX concentration. The best-performing VAE (β = 1) was subsequently trained on real intraoperative data, and its detection sensitivity was compared to annotations from four experienced surgeons. Results: The proposed model achieved the highest detection rates on synthetic test data when calibrated for 99% specificity. Applied to real intraoperative images, the model revealed fluorescent areas substantially larger than those marked by experienced surgeons. In non-5-ALA control cases, minimal false positives were observed, indicating a specificity exceeding 99.9%. The regression model reliably quantified PPIX concentration in synthetic samples (R2=0.92). Conclusions: By enabling more sensitive and objective fluorescence detection, this approach offers a valuable tool for improving surgical decision-making and facilitating safer, more extensive tumor resections.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.