Abstract
Healthcare facilities present significant architectural challenges due to their high usage intensity and diverse functions. Clinics, which accommodate both emergency interventions and routine check-ups, create a complex usage structure by integrating distinct functions within the building’s overall operation. Simultaneously optimising environmental quality within a structure hosting such varied functions is a critical architectural challenge. Room depth—which varies according to the function of the spaces—poses a significant obstacle to daylight penetration into the interior. Taking the room depth parameter into account, this study aims to propose cost-effective clinic designs that prioritise user comfort through a Building Information Modelling (BIM)-based optimisation framework. To this end, the study developed a BIM-based simulation model and a Building Energy Model (BEM) using a Python interface. Utilising the generated parametric BIM model, the study created a surrogate model based on various design variables and façade configuration alternatives, adopting a Pareto-front-based Multi-Objective Optimisation method. The case study examined three coastal locations across different regions in Turkey to demonstrate the generalizability of the BIM-based methodology. The results underscore the necessity of addressing conflicting performance criteria through a performance-based design approach within a balancing Life Cycle Cost framework.