Skip to Content
You are currently on the new version of our website. Access the old version .
SustainabilitySustainability
  • Article
  • Open Access

15 August 2023

12 Pages

Fire Safety Resilience Assessment of Residential Self-Built Houses according to the TOPSIS Method

,
,
,
and
1
School of Emergency Management, Henan Polytechnic University, Jiaozuo 454000, China
2
School of Energy Science and Engineering, Henan Polytechnic University, Jiaozuo 454000, China
3
Publicity and Education Center, Emergency Management Department, Beijing 100013, China
4
School of Safety Science and Engineering, Henan Polytechnic University, Jiaozuo 454000, China

Abstract

Fire extinguishing in residential self-built houses is difficult, and casualties are likely to occur. The aim of this study was to improve the fire safety resilience of residential self-built houses and decrease fire safety hazards. Firstly, the connotation of fire resilience of residential self-built houses was scientifically defined according to resilience theory. Then, a fire safety resilience evaluation index system with resistance, response and learning as the core was developed based on the properties of residential self-built houses, legal norms and relevant literature. At the same time, to weaken the effects of subjective factors, a fire safety resilience evaluation model of residential self-built houses was established based on a combination weighting–similarity to ideal solution (TOPSIS) method to quantify the influence of each index and divide the resilience level standards. Finally, a practical case of a residential self-built house in Jiaozuo City was adopted for resilience assessment for the verification of the scientificity and rationality of the model. The results showed the following. (1) In the evaluation system, the proportion of the coping and learning stages was 75%, and improving this factor significantly promoted the fire safety resilience of residential self-built houses. (2) Through TOPSIS, the fire safety resilience of residential self-built houses was classified into four groups of poor, medium, good and excellent. (3) By performing an example test, the fire safety resilience level of this residential self-built house was found to be medium, and the evaluation results were basically consistent with the actual situation of the building, which verified the scientificity and rationality of the proposed model.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.