Indoor Air Quality Improvement in Public Toilets at Railway Stations in China: A Field and Numerical Study

School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
*
Author to whom correspondence should be addressed.
Sustainability 2023, 15(11), 8720; https://doi.org/10.3390/su15118720
Submission received: 30 March 2023 / Revised: 9 May 2023 / Accepted: 23 May 2023 / Published: 29 May 2023
(This article belongs to the Special Issue Architecture and Indoor Environmental Quality)

Abstract

This study investigated the air quality and ventilation systems of 22 public toilets in 10 railway stations in China. Approximately 80% of public toilets meet the standard for ammonia concentration in Class I toilets, while 20% exceed the standard. It was found that the concentration of pollutants is mainly related to the number of toilet users and the ventilation system. In 20% of public toilets, the change in ammonia concentration was delayed by about 1 to 2 h with the change in hourly service number. In order to improve the air quality, a design method for calculating the number of toilet cubicles was proposed. Results show that the service capacity of the cubicle per hour (SCCH) of a female toilet is 12, the SCCH of male toilets is related to the ratio of squatting pans to urinals (RSU), which is suggested to be 1:1~1:0.8, and the corresponding SCCH is 16~20. Then, the effect of different ventilation forms was simulated by computational fluid dynamics (CFD) 2019 software. The results show that the bottom exhaust was better than the top exhaust and that the fresh air supply system is unnecessary. The recommended ventilation rate for toilets is 20 air changes per hour (ACH). The scale design method of toilets proposed in this paper was meant to address the gender imbalance and avoid queuing and provides a reference for the renovation and design of public toilets.
Keywords: air quality; ammonia concentration; ventilation system; public toilet; railway station air quality; ammonia concentration; ventilation system; public toilet; railway station

Share and Cite

MDPI and ACS Style

Yu, J.; Qian, C.; Zhao, J.; Tao, J.; Leng, K.; Xu, X. Indoor Air Quality Improvement in Public Toilets at Railway Stations in China: A Field and Numerical Study. Sustainability 2023, 15, 8720. https://doi.org/10.3390/su15118720

AMA Style

Yu J, Qian C, Zhao J, Tao J, Leng K, Xu X. Indoor Air Quality Improvement in Public Toilets at Railway Stations in China: A Field and Numerical Study. Sustainability. 2023; 15(11):8720. https://doi.org/10.3390/su15118720

Chicago/Turabian Style

Yu, Jinghua, Congcong Qian, Jingang Zhao, Junwei Tao, Kangxin Leng, and Xinhua Xu. 2023. "Indoor Air Quality Improvement in Public Toilets at Railway Stations in China: A Field and Numerical Study" Sustainability 15, no. 11: 8720. https://doi.org/10.3390/su15118720

APA Style

Yu, J., Qian, C., Zhao, J., Tao, J., Leng, K., & Xu, X. (2023). Indoor Air Quality Improvement in Public Toilets at Railway Stations in China: A Field and Numerical Study. Sustainability, 15(11), 8720. https://doi.org/10.3390/su15118720

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop