Next Article in Journal
Hemoglobin SE Disease in Hatay, in the Southern Part of Turkey
Previous Article in Journal
Are We United Enough to Come Down with Common Charter of Demands: The Health Professionals’ Perspective
 
 
Thalassemia Reports is published by MDPI from Volume 12 Issue 1 (2022). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

The Example of the UK SHOT Haemovigilance System

by
Perla Eleftheriou
St Bartholomew's Hospital, London, UK
Thalass. Rep. 2014, 4(3), 4858; https://doi.org/10.4081/thal.2014.4858
Submission received: 4 January 2014 / Revised: 4 September 2014 / Accepted: 30 November 2014 / Published: 4 December 2014

Abstract

SHOT (Serious Hazards of Transfusion scheme) is the UK’s National confidential haemovigilance system, and was set up in 1996. It is an independent, confidential, professionally led haemovigilance scheme. Initially the reporting was voluntary but now required by several professional bodies. SHOT publishes annual reports with recommendations and circulates to all relevant organizations including the 4 UK Blood services, Departments of Health in England, Wales, Scotland and Northern Ireland, all relevant professional bodies and reporting hospitals. Over the 17 years of reporting, the evidence gathered has prompted changes in transfusion practice from the selection and management of donors to changes in hospital practice, better education and training. Acute transfusion reactions and transfusion-associated circulatory overload carry the highest risk for morbidity and death. Greatest risk to patients remain errors in the process at the point of blood sampling, in the laboratory and at bedside administration. SHOT’s objectives are to use findings to improve standards of hospital transfusion practice, to educate users on transfusion hazards and prevention, to aid production of clinical guidelines in blood transfusion and to inform national policy on transfusion safety. MHRA is the UK competent authority to which serious adverse reactions and events have to be reported annually. Overall the most common adverse incidents are caused by errors, resulting in the transfusion of an incorrect component or one that does not meet the specific requirements of the patient (e.g. not irradiated or not appropriately antigen matched). TACO (transfusion associated circulatory overload) accounts for most deaths and major morbidity reported to SHOT but is overall underreported. Transfusions are not always given appropriately. This may be due to wrong haemoglobin results, failure to assess patients appropriately, or avoidable use of emergency O RhD negative units because of poor communication or planning. Review of cases of haemolytic transfusion reactions (HTR) shows that they are observed mainly in Sickle Cell Disease patients. HTR are associated with major morbidity (10/16 cases in sickle cell patients over 3 years) and death (a child in 2010). SCD patients are at particular risk of alloimmunization and this can be reduced by red cell phenotyping prior to the first transfusion followed by routine matching for at least the Rh and Kell groups. SHOT output data led over the time to the development of strategies to improve transfusion safety such as the implementation of guidelines for improving practice, implementation of the National Comparative Audit of Blood Transfusion programme, the publication of the Better blood transfusion initiatives and the establishment of The UK transfusion laboratory collaborative.
Keywords: UK SHOT; haemovigilance system; haemolytic transfusion reactions; haemoglobin UK SHOT; haemovigilance system; haemolytic transfusion reactions; haemoglobin

Share and Cite

MDPI and ACS Style

Eleftheriou, P. The Example of the UK SHOT Haemovigilance System. Thalass. Rep. 2014, 4, 4858. https://doi.org/10.4081/thal.2014.4858

AMA Style

Eleftheriou P. The Example of the UK SHOT Haemovigilance System. Thalassemia Reports. 2014; 4(3):4858. https://doi.org/10.4081/thal.2014.4858

Chicago/Turabian Style

Eleftheriou, Perla. 2014. "The Example of the UK SHOT Haemovigilance System" Thalassemia Reports 4, no. 3: 4858. https://doi.org/10.4081/thal.2014.4858

APA Style

Eleftheriou, P. (2014). The Example of the UK SHOT Haemovigilance System. Thalassemia Reports, 4(3), 4858. https://doi.org/10.4081/thal.2014.4858

Article Metrics

Back to TopTop