Abstract
This study estimates a lithium-ion battery’s usable capacity from observed discharge onset to 3.0 V using voltage measurements within the first 180 s. Comparisons use 4864 discharge records from 12 cells in the National Aeronautics and Space Administration (NASA) and Center for Advanced Life Cycle Engineering (CALCE) datasets, with test cells excluded from fitting and parameter selection. A fixed slope-based support vector regression (SVR) candidate with a radial basis function (RBF) kernel achieves equal-cell mean absolute errors of 31.4 mAh in NASA development Group A and 33.5 mAh in CALCE, compared with 55.2 and 71.4 mAh for linear-kernel SVR. A broader NASA feature/model-selection procedure gives 34.3 mAh. Duration normalization explains part of the endpoint-to-slope improvement. A matched six-voltage comparison reduces CALCE error to 20.1 mAh with SVR and 17.4 mAh with Gaussian process regression, while the scalar slope remains the best of the four tested combinations on NASA. For slope-based RBF-SVR, the lowest errors among tested budgets occur at 180 s in NASA and 300 s in CALCE. Direct NASA Group A-to-B transfer produces systematic underestimation in three target cells. Full-discharge diagnostics show how nearly matching early curves later separate in charge delivery. The results support controlled early-voltage diagnostics, with population-specific validation of input representations, observation budgets and fitted mappings.