Abstract
Electric vehicle thermal validation requires evidence on battery response and environmental heat exposure, whose limitations are explicit. We analysed 492 complete records (28.9% of a heterogeneous literature database, not restricted to electric vehicle cells) and hourly temperatures from the fifth-generation European Centre for Medium-Range Weather Forecasts reanalysis (ERA5) at 54 African reference grid points. A two-group Ward partition showed an approximately 11.5-fold difference in median heating rate within this cohort. Excluding 16 records with possible sodium-ion labels changed 22.3% of retained designations, and the adjusted Rand index (ARI) was 0.302. Across 2002 equal-sized random deletions, the median changed fraction was 9.7%, and 8.75% produced an ARI no higher than the specified screen. Retaining the original standardisation parameters reproduced the screened. Omitting each of 102 source studies in turn gave a median ARI of 0.708 under refitted standardisation, with a range of 0.271–1.000. For 2002–2025, alternative thresholds and weights produced rank correlations of 0.976–0.996, but individual points shifted by up to eleven positions. The point-based indicators omit solar loading and vehicle heat accumulation and do not represent national operating environments. The results demonstrate cohort-dependent grouping and relative heat-exposure ordering under the selected definitions. They support a framework for planning local operating, cooling and abuse-consequence measurements, rather than a calibrated assessment of battery failure risk.