Development and Evaluation of Real-Time Fluorescence and Visual LAMP Assays for the Detection of Lumpy Skin Disease Virus

,
,
,
,
,
,
,
,
…
1
Hebei Key Laboratory of Preventive Veterinary Medicine, College of Animal Science and Technology, Hebei Normal University of Science and Technology, Qinhuangdao 066004, China
2
Erlianhot International Travel Health Care Center, Erlianhot 011100, China
3
Institute of Microbiology, University of Agriculture Faisalabad, Faisalabad 38000, Pakistan
4
School of Veterinary Medicine, Mongolian University of Life Sciences, Ulaanbaatar 17024, Mongolia
This article belongs to the Section Animal Viruses

Abstract

Rapid nucleic acid detection of lumpy skin disease virus (LSDV) is important for disease surveillance and control. In this study, a conserved region of the gene encoding the LSDV poxvirus_F11 superfamily protein was selected as the target sequence. Candidate LAMP primers were designed and screened, and a real-time fluorescence LAMP assay was established following optimisation of the reaction conditions. A visual LAMP assay was subsequently developed by comparing the performance of four colourimetric indicators, with cresol red selected for visual detection. Infectious bovine rhinotracheitis virus (IBRV), goatpox virus (GTPV), foot-and-mouth disease virus (FMDV) and bovine viral diarrhoea virus (BVDV) were used to evaluate cross-reactivity. Analytical sensitivity was assessed using 10-fold serial dilutions of the recombinant plasmid pUC57-Gene1, and 100 samples were tested to evaluate assay performance. No cross-amplification was observed with the non-target viruses tested. In the tested dilution series, the lowest concentration at which a positive result was observed was 10 copies/μL for real-time fluorescence LAMP (2/3 replicates), whereas visual LAMP consistently yielded positive results at 100 copies/μL (3/3 replicates). These values represent observed assay endpoints under the conditions tested and should not be interpreted as statistically validated 95% limits of detection (LoD95). Using the WOAH-recommended qPCR assay as the reference method, all 30 reference-positive samples were detected by real-time fluorescence LAMP, whereas 29 were detected by visual LAMP. All 70 reference-negative samples tested negative by both assays. The relative sensitivities of the real-time fluorescence LAMP and visual LAMP assays were 100% (95% CI: 88.4–100%) and 96.7% (95% CI: 82.8–99.9%), respectively, while the relative specificity was 100% (95% CI: 94.9–100%) for both assays. These results indicate good agreement with the reference method within the evaluated sample set. The visual LAMP assay additionally allows direct interpretation based on a colour change, providing an alternative option for LSDV detection under different testing conditions.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.