Review Reports
- Mohammed Hassan 1,
- Nawaf Alshdaifat 2 and
- Suhaila Abuowaida 7
- et al.
Reviewer 1: Anonymous Reviewer 2: Anonymous Reviewer 3: Yunus Doğan Reviewer 4: Anonymous Reviewer 5: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsThe manuscript proposes Hy-DTGL, a 2D transformer for multi-modal brain MRI super-resolution that fuses four parallel branches (windowed local attention, pooled global attention, FFT modulation, DWT refinement).
- The abstract reports 36.24 dB / 0.982 SSIM on BraTS 2020 ×4, with margins of +1.25 dB over ECFNet and +2.83 dB over WavTrans. In Table 9 these are exactly TRT-GLA [49]'s numbers and margins, while Hy-DTGL is listed as 37.46 / 0.986.
- The PSNR/SSIM insets in the qualitative figures (e.g., 42.53/0.996 at ×2, 36.24/0.982 at ×4) also match TRT-GLA's Table 9 entries rather than Hy-DTGL's. Leftovers such as "TGSA blocks", "Hy-DST", and "simultaneously models three key processes… all three domains" (lines 188–192) point the same way. The authors must state precisely what is new relative to [49] and which text and figures are reused.
- The only substantive difference from [49] appears to be the wavelet branch. No ablation isolates it (spectral and wavelet are added together in Table 6), and the gain over TRT-GLA (+1.2 dB) comes without any statistical testing.
- IXI contains T1/T2/PD/MRA/DTI and has no T1CE or FLAIR, yet the paper states that all four datasets provide the same four co-registered sequences and feeds a 4-channel input. How IXI was evaluated is unexplained and, as described, impossible.
- The "strict zero-shot" claim is invalid as stated: the BraTS 2020 training set contains the BraTS 2019 cases, and BraTS 2023 GLI reuses earlier BraTS subjects. Without subject-level de-duplication, test subjects may have been seen during training.
Author Response
|
Manuscript ID |
|
|
Title
|
Integrating Spatial, Spectral, and Wavelet Domains via Global-Local Attention for Robust Multi-Modal MRI Super-Resolution
|
Dear Reviewer_1,
We sincerely thank the reviewer for their meticulous reading, sharp observations, and constructive feedback. We acknowledge the clerical oversights regarding the copied metrics and text remnants from our previous work [49]. We have thoroughly revised the manuscript to correct these errors, clarify the distinct novelty of the proposed Hy-DTGL framework, address the dataset inconsistencies, and strengthen the statistical validation of our claims. Below are our point-by-point responses and the corresponding revisions.
Author detailed response:
|
Comment 1: The abstract reports 36.24 dB / 0.982 SSIM on BraTS 2020 ×4, with margins of +1.25 dB over ECFNet and +2.83 dB over WavTrans. In Table 9 these are exactly TRT-GLA [49]'s numbers and margins, while Hy-DTGL is listed as 37.46 / 0.986. Response: We sincerely thank the reviewer for their meticulous attention to detail. We acknowledge this clerical oversight and confirm that the Abstract inadvertently contained the performance metrics of the TRT-GLA baseline rather than our proposed Hy-DTGL framework. We have corrected the Abstract to accurately reflect the true performance of Hy-DTGL (37.46 dB PSNR, 0.986 SSIM) and its correct performance margins over the baselines (+2.47 dB over ECFNet and +4.05 dB over WavTrans in PSNR), ensuring complete consistency with Table 9. Revised text: |
|
Comment 2: The PSNR/SSIM insets in the qualitative figures (e.g., 42.53/0.996 at ×2, 36.24/0.982 at ×4) also match TRT-GLA's Table 9 entries rather than Hy-DTGL's. Leftovers such as "TGSA blocks", "Hy-DST", and "simultaneously models three key processes… all three domains" (lines 188–192) point the same way. The authors must state precisely what is new relative to [49] and which text and figures are reused. Response: We thank the reviewer for identifying these critical editing oversights. We confirm that the figure insets contained outdated metrics from our previous work [49], and the manuscript retained legacy terminology and phrasing. We have systematically corrected all remnants and regenerated all qualitative figures with the correct Hy-DTGL metrics. Regarding the novelty relative to [49] (TRT-GLA), the current work proposes a fundamentally distinct Quad-Domain architecture with the following key advancements:
|
|
Comment 3: The only substantive difference from [49] appears to be the wavelet branch. No ablation isolates it (spectral and wavelet are added together in Table 6), and the gain over TRT-GLA (+1.2 dB) comes without any statistical testing. Response: We thank the reviewer for this insightful and constructive observation. We agree that isolating the explicit contribution of the wavelet branch and providing rigorous statistical validation are essential to substantiate the performance gains over the baseline TRT-GLA [49]. To address this comprehensively, we have implemented the following revisions:
|
|
Comment 4: IXI contains T1/T2/PD/MRA/DTI and has no T1CE or FLAIR, yet the paper states that all four datasets provide the same four co-registered sequences and feeds a 4-channel input. How IXI was evaluated is unexplained and, as described, impossible. Response: We sincerely thank the reviewer for highlighting this critical methodological inconsistency. The reviewer is entirely correct: the IXI dataset does not contain T1CE or FLAIR sequences, and our original phrasing incorrectly implied a uniform 4-channel input across all datasets. To address this, we have made two key revisions to ensure complete transparency and methodological rigor:
|
|
Comment 5: The "strict zero-shot" claim is invalid as stated: the BraTS 2020 training set contains the BraTS 2019 cases, and BraTS 2023 GLI reuses earlier BraTS subjects. Without subject-level de-duplication, test subjects may have been seen during training. Response: We acknowledge the reviewer's expertise regarding the BraTS dataset composition. The term "strict zero-shot" was indeed an overstatement given the known subject overlap between BraTS editions. We have retracted this term and replaced it with "cross-dataset generalization." Furthermore, we have implemented and documented a rigorous subject-level deduplication protocol to ensure no data leakage. |
Author Response File:
Author Response.docx
Reviewer 2 Report
Comments and Suggestions for AuthorsThis manuscript presents Hy‑DTGL, a quad‑domain hybrid transformer for multi‑modal brain MRI super‑resolution. It innovatively combines local‑global spatial attention, learnable spectral modulation and wavelet multi‑scale decomposition. Extensive tests including ablation studies, zero‑shot cross‑dataset evaluation and downstream tumor segmentation verify its competitive performance against state‑of‑art methods on public brain MRI datasets. I think the methods mentioned in the paper are effective, but there are still some issues in the manuscript that need to be addressed by the author
- The model is trained with synthetic bicubic degradation. Please clarify how these results transfer to real clinical MRI with motion, scanner‑specific PSF and other physical distortions.
- Zero‑shot results show performance gaps between tumor BraTS data and healthy IXI data. Please explain the reason for this difference?
- Table 14 mentions the total error ratio of three types of segmentation error source points. What is the basis for these data?
- It is recommended to center the content of the table in all directions, such as Table 1, 5, etc.
- In Figure 3, except for the first character diagram with a legend, the other three diagrams do not have a legend?
Author Response
|
Manuscript ID |
|
|
Title
|
Integrating Spatial, Spectral, and Wavelet Domains via Global-Local Attention for Robust Multi-Modal MRI Super-Resolution
|
Dear Reviewer 2,
We sincerely thank the reviewer for their positive evaluation of our work and for their insightful, constructive comments. We have carefully addressed each point raised, providing methodological clarifications, updating the manuscript text, and refining the figures and tables to improve the overall quality and readability of the paper. Below are our point-by-point responses.
|
Comment 1: The model is trained with synthetic bicubic degradation. Please clarify how these results transfer to real clinical MRI with motion, scanner specific PSF and other physical distortions. Response: We thank the reviewer for raising this crucial point regarding the gap between synthetic and real-world clinical degradation. We acknowledge that while bicubic downsampling provides a controlled baseline, real clinical MRI is subject to complex physical distortions such as patient motion, scanner-specific Point Spread Function (PSF) variations, and k-space truncation artifacts. To address this, we highlight that our Sensitivity Analysis (Table 11) already demonstrates the model's robustness to complex, non-ideal degradations, including varying blur kernels, noise levels, and anisotropic blurring, where the spectral and wavelet constraints effectively prevent the amplification of unnatural artifacts. Furthermore, we have explicitly expanded the Limitations section in the Discussion to acknowledge this gap and frame "acquisition-aware degradation modeling" as a primary direction for our future work. Revised text: |
|
Comment 2: Zero shot results show performance gaps between tumor BraTS data and healthy IXI data. Please explain the reason for this difference? Response: We appreciate the reviewer’s keen observation. The performance difference (where IXI often yields slightly higher PSNR/SSIM scores than BraTS datasets, e.g., 39.10 dB vs. 37.46 dB at ×4) is an expected and scientifically justifiable phenomenon in medical image SR. The primary reason is anatomical complexity. The IXI dataset consists of healthy brain scans, which feature smooth, homogeneous tissue structures and predictable anatomical boundaries. In contrast, the BraTS datasets contain highly heterogeneous, irregular, and high-frequency pathological structures (e.g., necrotic cores, infiltrating edema, and irregular enhancing rims). Reconstructing these chaotic, low-contrast tumor boundaries is inherently more ill-posed and challenging than reconstructing healthy tissue. The fact that Hy-DTGL maintains exceptionally high performance on IXI confirms its strong generalization to healthy anatomy, while the slight drop on BraTS reflects the genuine difficulty of the pathological reconstruction task. |
|
Comment 3: Table 14 mentions the total error ratio of three types of segmentation error source points. What is the basis for these data? Response: We thank the reviewer for requesting this methodological clarification. The percentages in Table 14 were derived through a systematic, voxel-wise error analysis. Specifically, we generated binary error maps by computing the logical XOR (absolute difference) between the High-Resolution (HR) ground-truth segmentation masks and the segmentation masks generated from the Hy-DTGL super-resolved images. These error voxels were then categorized based on two criteria: (1) their spatial distance from the ground-truth tumor boundary (using a distance transform), and (2) their visual morphology (e.g., scattered isolated voxels were classified as "Micro-Artifacts," while contiguous shifted regions were classified as "Over-Smoothing"). This categorization was visually validated by two independent clinical observers to ensure accuracy. |
|
Comment 4: It is recommended to center the content of the table in all directions, such as Table 1, 5, etc. Response: We thank the reviewer for this formatting suggestion. We have revised all tables in the manuscript (including Table 1, Table 5, Table 6, Table 9, etc.) to ensure that all text and numerical content is horizontally and vertically centered within their respective cells, improving overall readability and adhering to journal formatting standards. |
|
Comment 5: In Figure 3, except for the first character diagram with a legend, the other three diagrams do not have a legend? Response: We sincerely apologize for this oversight. We have updated Figure 3 to include clear, consistent legends (indicating "Train" and "Validation" curves) in all four subplots (Loss, PSNR, SSIM, and MS-SSIM) to ensure the training dynamics are easily interpretable for the reader. |
Author Response File:
Author Response.docx
Reviewer 3 Report
Comments and Suggestions for AuthorsThe manuscript proposes Hy-DTGL, a quad-domain transformer framework (Local Spatial, Global Spatial, Spectral, and Wavelet) designed for multi-modal MRI super-resolution (SR).
Optimized with a hybrid loss function (Charbonnier, Sobel, and Fourier) and Test-Time Augmentation (TTA), the model is validated on BraTS 2019, 2020, 2023, and |X| datasets across ×2, ×4, and ×8 upsampling factors, including downstream evaluations for brain tumor segmentation and volumetry. Some limitations and recommendations are as follows:
The framework primarily relies on bicubic downsampling to simulate low-resolution inputs. Incorporating or explicitly discussing physics-based degradation models, such as k-space truncation, anisotropic slice thickness, and hardware-specific noise, would better align the method with real-world clinical acquisitions.
Operating on 2D slices can introduce inter-slice step artifacts when reconstructed back into 3D volumes. Incorporating mechanisms to preserve 3D spatial continuity or thoroughly discussing the trade-offs of 2D processing compared to 3D networks is recommended.
While the model is primarily named Hy-DTGL, alternative terms like Hy-DST and TRT-GLA appear across certain figures and tables. Unified nomenclature and clear architectural distinctions should be established throughout the text.
In Section II.B.2, equation dimensions and feature shapes are incomplete.
In Section II.B.5, the cross-domain fusion equation shows 1 × 11 × 1 convolution due to a formatting typo 1 × 1.
Ensure Figure numbers in the text strictly align with the figure captions (for example; Figure 2 and Figure 3 captions are repeated/mismatched in the discussion text).
Comments on the Quality of English LanguageFurthermore, we recommend a thorough proofreading of the entire manuscript to fix language errors, minor typos, and formatting inconsistencies throughout the text. For example; Section I: "36.24 d B PSNR" -> "36.24 dB PSNR", Section I: "Test-Time Augmentation (TTA), consisting of 8 geometrical transformations..." -> rephrase for smoother English flow.
Author Response
|
Manuscript ID |
|
|
Title
|
Integrating Spatial, Spectral, and Wavelet Domains via Global-Local Attention for Robust Multi-Modal MRI Super-Resolution
|
Dear Reviewer 3,
We sincerely thank the reviewer for their thorough evaluation and highly constructive feedback. We appreciate the insightful recommendations regarding degradation modeling, 2D/3D trade-offs, nomenclature consistency, and manuscript formatting. We have carefully addressed each point, refining the text, correcting typographical errors, and enhancing the scientific clarity of the manuscript. Below are our point-by-point responses.
|
Comment 1: The framework primarily relies on bicubic downsampling to simulate low-resolution inputs. Incorporating or explicitly discussing physics-based degradation models, such as k-space truncation, anisotropic slice thickness, and hardware-specific noise, would better align the method with real-world clinical acquisitions. Response: We agree with the reviewer that incorporating physics-based degradation models is crucial for bridging the gap between synthetic benchmarks and real-world clinical MRI. While bicubic downsampling serves as our primary controlled baseline, we have explicitly expanded our discussion to address this limitation and highlight our existing robustness evaluations (Table 11), while clearly framing comprehensive physics-based modeling as a primary direction for future work. |
|
Comment 2: Operating on 2D slices can introduce inter-slice step artifacts when reconstructed back into 3D volumes. Incorporating mechanisms to preserve 3D spatial continuity or thoroughly discussing the trade-offs of 2D processing compared to 3D networks is recommended. Response: This is a highly valid and important point. We have added a dedicated paragraph in the Discussion/Limitations section to thoroughly address the trade-offs of 2D processing. We acknowledge the potential for inter-slice artifacts and justify the current 2D approach based on computational efficiency, while committing to 3D volumetric architectures in future work. |
|
Comment 3: While the model is primarily named Hy-DTGL, alternative terms like Hy-DST and TRT-GLA appear across certain figures and tables. Unified nomenclature and clear architectural distinctions should be established throughout the text. Response: We apologize for this inconsistency, which stemmed from earlier drafts. We have conducted a comprehensive search and replace throughout the entire manuscript. Our proposed model is now uniformly referred to as Hy-DTGL. The term TRT-GLA is retained only when explicitly referring to the baseline method in Reference [49] for comparative purposes, which is now clearly distinguished in the text and tables. Action Taken: All instances of "Hy-DST" and "TGSA" have been permanently replaced with "Hy-DTGL" and "Hy-DTGL Quad-Domain modules" respectively, ensuring strict nomenclature consistency. |
|
Comment 4: In Section II.B.2, equation dimensions and feature shapes are incomplete. Response: We thank the reviewer for catching this incomplete sentence. We have revised Section 3.B.2 to clearly define the feature shapes and dimensions resulting from the spatial pooling operation. |
|
Comment 5: In Section II.B.5, the cross-domain fusion equation shows 1 × 11 × 1 convolution due to a formatting typo 1 × 1. Response: We apologize for this typographical error. It has been corrected to accurately reflect a standard convolution. |
|
Comment 6: Ensure Figure numbers in the text strictly align with the figure captions (for example; Figure 2 and Figure 3 captions are repeated/mismatched in the discussion text). Response: We thank the reviewer for their meticulous reading. We have carefully reviewed the Discussion section and corrected all mismatched figure references to ensure they strictly align with the actual content of the figures. |
|
Comment 7: Furthermore, we recommend a thorough proofreading of the entire manuscript to fix language errors, minor typos, and formatting inconsistencies throughout the text. For example; Section I: "36.24 d B PSNR" -> "36.24 dB PSNR", Section I: "Test-Time Augmentation (TTA), consisting of 8 geometrical transformations..." -> rephrase for smoother English flow. Response: We sincerely appreciate this recommendation. The entire manuscript has undergone a thorough proofreading process. We have corrected all spacing typos (e.g., "d B" to "dB"), fixed grammatical inconsistencies, and rephrased awkward sentences to ensure a smooth, professional, and native-level academic English flow. |
Author Response File:
Author Response.docx
Reviewer 4 Report
Comments and Suggestions for Authors- Authors must clarify the experimental and training settings, adding the learning-rate description and cosine annealing settings can significantly improve the reproducibility.
- This study will be further strengthened by adding statistical significance, confidence intervals and subject-level variability for the main comparisons.
- The authors must provide the justification for the clinical interpretation of volumetric error.
- Improve the presentation of the segmentation error analysis. How the authors made the error categories and their percentages were determined, including whether the assessment was automated, manually reviewed, or based on predefined quantitative criteria.
- Some sentences in the discussion and conclusion are grammatically complex. Remove all the typographical errors.
- For segmentation, add these articles: "SkinDWNet: a novel deep learning model for multiclass classification of skin cancers using dermoscopic images" "Deep Learning-Enhanced Brain Tumor Prediction via Entropy-Coded BPSO in CIELAB Color Space"
Author Response
|
Manuscript ID |
|
|
Title
|
Integrating Spatial, Spectral, and Wavelet Domains via Global-Local Attention for Robust Multi-Modal MRI Super-Resolution
|
Dear Reviewer 4,
We sincerely thank the reviewer for their constructive feedback, which has helped us enhance the clarity, reproducibility, and clinical grounding of our manuscript. We have carefully addressed each point, expanded the methodological details, refined the clinical justifications, and incorporated the recommended literature. Below are our point-by-point responses.
|
Comment 1: Authors must clarify the experimental and training settings, adding the learning-rate description and cosine annealing settings can significantly improve the reproducibility. Response: We agree with the reviewer that explicit training details are crucial for reproducibility. While basic parameters were listed in Table 3, we have now expanded the text in Section 4.B (Implementation Details) to provide a comprehensive description of the learning rate schedule and cosine annealing parameters.
|
|
Comment 2: This study will be further strengthened by adding statistical significance, confidence intervals and subject-level variability for the main comparisons. Response: We appreciate this recommendation. In response to previous reviewers, we have already integrated statistical significance testing and subject-level variability metrics throughout the manuscript. We have now further highlighted these additions to ensure they fully address the reviewer’s concern:
|
|
Comment 3: The authors must provide the justification for the clinical interpretation of volumetric error. Response: This is a highly valuable point. We have expanded the justification in Section G.4 to explicitly link our volumetric error margins to established neuro-oncological clinical standards. Specifically, we reference that measurement variability must remain well below the thresholds used to define true tumor progression (e.g., the RANO criteria, which often require volume increase to confirm progression), making a error margin highly reliable for longitudinal monitoring. |
|
Comment 4: Improve the presentation of the segmentation error analysis. How the authors made the error categories and their percentages were determined, including whether the assessment was automated, manually reviewed, or based on predefined quantitative criteria. Response: We thank the reviewer for prompting us to clarify this methodology. We have revised Section G.3 to explicitly state that our error analysis utilizes a two-step hybrid approach: an initial automated quantitative generation followed by manual clinical validation. |
|
Comment 5: Some sentences in the discussion and conclusion are grammatically complex. Remove all the typographical errors. Response: We sincerely apologize for any grammatical complexity or typographical oversights. We have conducted a thorough, line-by-line proofreading of the entire manuscript, with a specific focus on the Discussion and Conclusion sections. We have simplified overly complex sentence structures, corrected minor typographical errors (e.g., ensuring consistent spacing in "dB", "Hy-DTGL"), and improved the overall readability and flow of the academic English. Action Taken: Comprehensive proofreading and simplification of complex sentences applied throughout the Discussion and Conclusion sections. (No specific text replacement needed here, just a global improvement). |
|
Comment 6: For segmentation, add these articles: "SkinDWNet: a novel deep learning model for multiclass classification of skin cancers using dermoscopic images" "Deep Learning-Enhanced Brain Tumor Prediction via Entropy-Coded BPSO in CIELAB Color Space" Response: We thank the reviewer for recommending these relevant articles. We agree that highlighting the broad success of deep learning across various medical imaging segmentation and classification tasks strengthens the context of our work. We have added both references to the manuscript and cited them appropriately in the Introduction. |
|
Comment 7:
|
|
|
|
|
|
|
Author Response File:
Author Response.docx
Reviewer 5 Report
Comments and Suggestions for AuthorsThe manuscript proposes a potentially interesting quad-domain MRI super-resolution framework integrating local/global spatial attention, Fourier-domain modeling, and wavelet decomposition. The cross-dataset evaluation and downstream tumor-segmentation analysis are valuable aspects of the study. However, substantial revision is required in my opinion.
- The manuscript needs substantial language and technical editing. There are numerous incomplete or grammatically malformed sentences, duplicated symbols and missing mathematical expressions.
- There are serious numerical inconsistencies across the manuscript. The abstract reports BraTS 2020 ×4 = 36.24 dB PSNR and 0.982 SSIM, whereas Table 7 reports 37.46 dB and 0.986, and Table 9 also gives 37.46/0.986 for Hy-DTGL.
- Some sections report approximately 3.98 M parameters, 35.4 GFLOPs, and 0.142 s/image, while the later discussion apparently states approximately 31.4 GFLOPs and 0.102 s. The authors should recompute these values
- Table 9 compares Hy-DTGL against many methods and presents numerical performance differences as evidence of superiority. Authors are required to demonstrate that every method was evaluated using exactly the same dataset, preprocessing, degradation kernel, normalization, scaling procedure, metric implementation, and test protocol. Otherwise, directly comparing PSNR/SSIM numbers—especially numbers taken from different studies—is not scientifically valid.
- The manuscript should clearly describe the segmentation network’s training/testing partition, whether the segmentation model saw the same subjects during training, whether a single segmentation model was applied unchanged to all SR methods, and whether SR test images were completely independent of all model-selection procedures.
Author Response
|
Manuscript ID |
|
|
Title
|
Integrating Spatial, Spectral, and Wavelet Domains via Global-Local Attention for Robust Multi-Modal MRI Super-Resolution
|
Dear Reviewer 5,
We sincerely thank the reviewer for their rigorous and highly constructive evaluation. We acknowledge the oversights regarding numerical inconsistencies, typographical errors, and the need for clearer articulation of our evaluation protocols. We have conducted a comprehensive, line-by-line technical editing of the manuscript, corrected all numerical and computational discrepancies, and explicitly detailed our unified evaluation and segmentation protocols to ensure absolute scientific validity. Below are our point-by-point responses.
|
Comment 1: The manuscript needs substantial language and technical editing. There are numerous incomplete or grammatically malformed sentences, duplicated symbols and missing mathematical expressions. Response: We sincerely apologize for these oversights. We have conducted a thorough, line-by-line technical and linguistic proofreading of the entire manuscript. We have corrected all grammatical malformed sentences, removed duplicated symbols (e.g., the duplicated "α α" in Section 3.B.5 has been corrected to a single "α"), and ensured all mathematical expressions and feature shape descriptions (e.g., in Section 3.B.2) are complete and rigorously defined. Action Taken: Comprehensive technical editing and proofreading applied throughout the manuscript. (Specific fixes, such as the correction in Section 3.B.5, are detailed in the revised text below). |
|
Comment 2: There are serious numerical inconsistencies across the manuscript. The abstract reports BraTS 2020 ×4 = 36.24 dB PSNR and 0.982 SSIM, whereas Table 7 reports 37.46 dB and 0.986, and Table 9 also gives 37.46/0.986 for Hy-DTGL. Response: We thank the reviewer for catching this critical clerical error. The values in the Abstract were inadvertently copied from a baseline model (TRT-GLA) during an earlier drafting phase. We have now rigorously corrected the Abstract to perfectly align with the actual Hy-DTGL performance reported in Tables 7 and 9. |
|
Comment 3: Some sections report approximately 3.98 M parameters, 35.4 GFLOPs, and 0.142 s/image, while the later discussion apparently states approximately 31.4 GFLOPs and 0.102 s. The authors should recompute these values. Response: We thank the reviewer for identifying this discrepancy. The values in the Discussion section were remnants of an outdated draft and were not updated to reflect the final, authoritative computational profiling presented in Table 3 and Table 4. We have corrected the Discussion to strictly match the verified computational metrics (3.98 M parameters, 35.4 GFLOPs, and 0.142 s/image). |
|
Comment 4: Table 9 compares Hy-DTGL against many methods and presents numerical performance differences as evidence of superiority. Authors are required to demonstrate that every method was evaluated using exactly the same dataset, preprocessing, degradation kernel, normalization, scaling procedure, metric implementation, and test protocol. Otherwise, directly comparing PSNR/SSIM numbers—especially numbers taken from different studies—is not scientifically valid. Response: We completely agree with the reviewer that an "apples-to-apples" comparison is mandatory for scientific validity. We clarify that all baseline methods listed in Table 9 were evaluated in-house under our exact, unified evaluation protocol. We did not simply copy numbers from their respective papers. For every baseline, we utilized their official pre-trained weights (or retrained them following their published specifications) and processed them through our identical pipeline: the exact same BraTS 2020 test subjects, identical bicubic degradation kernels, identical intensity normalization, and the same slice-wise PSNR/SSIM metric implementation. This guarantees that the reported margins of improvement are strictly due to architectural superiority, not protocol discrepancies. |
|
Comment 5: The manuscript should clearly describe the segmentation network’s training/testing partition, whether the segmentation model saw the same subjects during training, whether a single segmentation model was applied unchanged to all SR methods, and whether SR test images were completely independent of all model-selection procedures. Response: This is a crucial methodological point. We have revised Section G.1 and G.2 to explicitly detail the segmentation protocol, eliminating any ambiguity regarding data leakage or evaluation fairness. Specifically, we clarify that: (1) The segmentation model was trained exclusively on the BraTS 2020 training set. (2) A single, fixed segmentation model was applied unchanged to evaluate all input conditions (LR, all SR variants, and HR). (3) The test subjects were completely unseen during both the SR training and the segmentation model-selection phases. |
Author Response File:
Author Response.docx
Round 2
Reviewer 2 Report
Comments and Suggestions for AuthorsConsidering that the authors have made revisions to the manuscript based on the review comments and clarified any doubts, I suggest accepting this manuscript.
Reviewer 3 Report
Comments and Suggestions for AuthorsThe authors have thoroughly addressed every piece of feedback and successfully incorporated the necessary revisions into the manuscript. Furthermore, in their 'Response to Reviewers', they have addressed all comments in a clear, polite, and well-justified manner.
As a result of these revisions, the scientific quality, methodological clarity, and overall readability of the paper have been significantly improved.
Reviewer 5 Report
Comments and Suggestions for AuthorsAuthors have answered all my questions and have incorporated all my suggestions. I have no further questions.