Abstract
In gravity-compressed air energy storage (G-CAES), a gravity-loaded pressure cylinder adjusts the reservoir volume to maintain the air pressure near its design value over the effective stroke. To investigate the coupling between cylinder motion and gas–solid heat transfer, a two-dimensional transient model was developed that couples compressible air flow, conjugate heat transfer, and cylinder dynamics. Simulated air temperatures were compared with measurements at the corresponding location at the bottom of a 1:10-scale reservoir. Initial charging proceeded through constant-volume pressurization before cylinder lift-off and near-isobaric, variable-volume charging thereafter. At lift-off, the expanding air did work on the moving boundary, contributing to the rapid decline in mean reservoir air temperature after its peak. At an inlet mass flow rate of 4.30 kg/s, increasing the inlet temperature from 293.15 to 333.15 K raised the peak mean air temperature by 40.41 K and shortened the time to peak from 2.64 to 2.36 min. At an inlet temperature of 333.15 K, increasing the inlet mass flow rate from 2.15 to 12.90 kg/s raised the peak by 21.31 K and shortened the time to peak from 4.72 to 0.78 min. Over 50 operating cycles, the mean end-of-cycle steel-lining temperature increased monotonically, with smaller increments in later cycles. The differences between successive cycles at matching phases decreased for both the mean air and steel-lining temperatures, indicating an approach to a repeatable periodic thermal response under the conditions investigated. The transient temperature fields can inform thermal load management and provide temperature inputs for subsequent steel-lining thermal stress analyses.