Thermo-Hydraulic Assessment of a Mountain-Slope Solar Chimney Power Plant with Adiabatic Cooling: Hourly Simulation for Abha, Saudi Arabia

1
Department of Mechanical Engineering, College of Engineering, King Khalid University, P.O. Box 394, Abha 61421, Saudi Arabia
2
Centerfor Engineering and Technology Innovations, King Khalid University, Abha 61421, Saudi Arabia

Abstract

Mountainous terrain can increase the effective height of a solar chimney without increasing its physical height. Using twelve months of measured hourly meteorological data from Abha, Saudi Arabia, this study develops a quasi-steady, one-dimensional thermo-hydraulic model of an inclined solar chimney plant that incorporates dry-adiabatic cooling in both the collector and chimney. For a 21.4 km2 collector installed on an idealized 12.95° slope with a 1000 m chimney, the predicted annual energy generation is approximately 350 GWh. Neglecting adiabatic cooling overestimates annual generation by 33% at the reference turbine loading, 46% at λ = 0.5, and 21% when the models are optimized separately. The model predicts an equivalent flat-ground chimney height of 0.71–0.79 times the terrain elevation gain for plants without a chimney (0.84 with the 1000 m chimney), whereas a previous CFD study reported 0.32–0.65. Digital elevation model (DEM) profiles yield 257–403 GWh annually, with a conditional estimate of 260–290 GWh for the moderate-slope sectors, without accounting for local ravines or construction constraints. Turbine loading, optical efficiency, and lapse rate govern performance. The flat-ground model predicts 40–63 kW for the Manzanares plant (nominally 50 kW), while the inclined configuration has been evaluated numerically but not experimentally validated.

1. Introduction

Saudi Arabia is expanding its electricity generation mix toward renewable energy sources, with an announced goal of approximately 130 GW of renewable energy capacity by 2030 [1], and large areas of the Kingdom receive over 2000 kWh m−2 of annual global horizontal irradiation [2]. Solar technologies that utilize this resource without requiring cooling water are therefore of special interest. Most of the capacity currently being developed is based on photovoltaic or concentrating solar power technologies. In contrast, the solar chimney represents an alternative approach, as it generates electricity using both direct and diffuse solar irradiation without requiring cooling water or moving components apart from the turbines. Moreover, its power output depends on the vertical height of the heated air column rather than solely on a high direct-normal irradiation component.
Abha, the administrative capital of Asir Province, is located in southwestern Saudi Arabia (18.2° N, 42.5° E), along the crest of the Sarawat (Asir) Mountains, at approximately 2200 m above sea level and near the escarpment that descends sharply toward the Red Sea coastal plain (Tihama). The experimental data used in this study (Section 2) indicate an annual global horizontal irradiation of 2187 kWh m−2, a direct-normal irradiation of 2090 kWh m−2, an average ambient air temperature of 18.9 °C, and an average atmospheric pressure of 787 hPa. The site therefore offers high solar energy potential, characterized by thin, cool air and steep topography. Along a southwestern transect from the station, the ground elevation decreases by 657 m over a distance of 4 km (Section 5.6). These conditions make the installation of a solar chimney collector on a mountain slope a promising option and establish the Asir escarpment as a suitable location for evaluating the concept (Figure 1).
Figure 1. Study locations. (a) Long-term average global horizontal irradiation of southwestern Saudi Arabia (1999–2018), with the Abha–TVTC and Jazan University stations; the rectangle marks the extent of panel (b). Map © 2019 The World Bank; source: Global Solar Atlas 2.0; solar resource data: Solargis (CC BY 4.0), cropped and annotated by the authors. (b) Terrain around Abha from the Copernicus GLO-30 digital elevation model (hill-shaded, contours every 500 m).
A solar chimney power plant (SCPP), also known as a solar updraft tower, comprises a large transparent collector that warms the air beneath it, a tall chimney, and one or more turbines located at the base of the chimney. The difference in density between the heated air and the surrounding atmosphere generates a continuous upward airflow, while the turbines convert a portion of the available pressure difference into electrical power [3,4,5,6]. The only grid-connected demonstration plant, constructed in Manzanares, Spain, confirmed the feasibility of the concept at a 50 kW scale [3,4], while commercial-scale systems have been proposed with chimney heights reaching nearly 1000 m [5,6]. For a given collector, the driving pressure increases with the vertical height over which the heated air column remains less dense than the surrounding air. Therefore, chimney height is the primary factor influencing power output, but it also represents a major source of structural cost and risk.

1.1. Literature Review

Following the Manzanares prototype [3,4] and the commercial-scale plant designs [5,6], thermal and engineering studies investigated the relationship between power output and collector area, chimney height, and turbine loading [7]. The models developed by Pretorius and Kröger [8,9], Kröger and Blaine [10], von Backström and Gannon [11,12], and Pasumarthi and Sherif [13] described the collector energy balance, the buoyancy forces driving airflow, and the pressure drop across the turbines. Subsequent studies investigated the selection of chimney height [14], mathematical modeling of the entire system [15], the power conversion unit [16], and the potential to concentrate the available energy at ground level [17]. The review studies by Zhou et al. [18] and Al-Kayiem and Aja [19] provided an overview of these developments. Additionally, site-specific studies conducted in the Mediterranean region [20] demonstrated the application of these models in assessing plant feasibility under different climatic conditions.
For tall solar chimney plants, the conditions of the surrounding atmosphere are important, because the air rising through the chimney cools at approximately the dry-adiabatic rate, whereas the ambient air generally experiences a lower cooling rate with altitude. Detailed models therefore account for compressible flow and vertical atmospheric temperature variations [8,9,10,11,12]. Pretorius and Kröger [21] investigated the influence of environmental conditions on a reference plant. The assumed daytime atmospheric profile (dry-adiabatic or standard) affected the annual power generation by less than 1%, while ambient wind decreased it by approximately 10%, and nocturnal temperature inversions primarily influenced nighttime generation. A recent review indicates that most models adopt the dry-adiabatic rate inside the plant and either the dry-adiabatic rate or the standard atmospheric profile outside it [22].
For inclined collectors, Zhou et al. [23] demonstrated using a compressible-flow model that the driving force must be calculated by accounting for gravity and the change in atmospheric density with elevation. They reported that omitting the integral formulation leads to inaccurate predictions for inclined plants when an incompressible-flow model is applied. Zhou et al. [24] further extended the analysis to include humid air. Von Allwörden et al. [25] proposed a one-dimensional compressible model for a solar chimney plant with an arbitrary slope, incorporating humid air, a turbine model, frictional losses, and heat-transfer losses.
The concept of utilizing natural terrain to provide additional height was introduced by Bilgen and Rheault [26] for high-latitude regions. They reported an overall thermal performance of slightly below 0.5% for inclined plants at Canadian locations, achieving up to 85% of the power output of comparable plants in southern regions with horizontal collectors. Cao et al. [27,28,29] investigated conventional and inclined solar chimney plants in China. Their heat-transfer model indicated that increasing the collector inclination angle enhanced winter performance but reduced summer performance. The optimal angle for Lanzhou was approximately 60°, while the primary losses included heat transfer to the ground, reflected solar radiation, and kinetic energy losses at the chimney outlet [28]. Inclined plants were considered suitable for the high-latitude northwestern regions, whereas conventional plants were more appropriate for southeastern China.
Li et al. [30] developed expressions for the power output and efficiency of a plant installed on a south-facing slope at 35° N, reporting higher values for both parameters compared with a horizontal collector of equal area and chimney height. Panse et al. [31] introduced the concept of an inclined chimney constructed along a mountainside. Koonsrisuk [32] analyzed a sloped collector that partially functions as a chimney and found that assuming identical density differences in the collector and chimney substantially overestimates the predicted performance. A subsequent second-law comparison with conventional plants was also conducted [33]. Baral [34] assessed an inclined plant incorporating a 190 m chimney at five locations in Nepal.
Zhou and Yang [35] proposed a floating chimney supported along a mountainside for the desert regions of northwestern China and estimated its electricity generation cost and potential. Zhou et al. [23] compared an inclined-collector plant featuring a collector height of 848 m and a vertical chimney of 123 m with conventional horizontal-collector systems. They found that its pressure potential and power output fell between those of plants equipped with 547 m and 971 m towers. In a later study, Zhou et al. [36] suggested utilizing natural anabatic winds to improve the performance of inclined collectors. Most of these models employ steady-state assumptions and rely on design-point or monthly averaged conditions.
Most three-dimensional CFD investigations have focused on the Manzanares geometry. Gholamalizadeh et al. [37] reported that increasing the inclination of the collector roof modifies the convective flow pattern and enhances the mass flow rate. Hassan et al. [38] examined collector slopes ranging from 4° to 10° and chimney divergence angles between 1° and 3°. Their results indicated that both airflow velocity and temperature increase with collector inclination. However, steeper slopes promote vortex formation and recirculation, which may adversely affect system performance. They also found that a chimney divergence angle of 1° increased the maximum velocity from 9.1 to 11.6 m s−1.
Keshari et al. [39] identified an optimal collector inclination of 6° for the Manzanares plant, resulting in a 9.2% increase in theoretical power compared with a horizontal collector, while recirculation appeared at inclination angles exceeding approximately 7°. Cüce et al. [40] demonstrated that a ground inclination of 0.5° increased the pilot plant power output from 54.3 to 63.95 kW. Similarly, Cuce et al. [41] reported maximum power generation at a collector inclination of 0.6° and a chimney divergence angle of 1.5°, achieving approximately 217 kW compared with 46 kW for the reference configuration.
For a location in the mountainous region of northern Iraq, Weli et al. [42] determined that a ground slope of 35° was optimal, reducing the required chimney height by 36% for an equivalent system volume and relocating the turbine inside the chimney. The maximum power output reached 47.7 kW in July. Rahimi-Larki et al. [43] investigated the influence of ambient crosswinds on inclined collectors. Their findings indicated that slopes between 20° and 30° enhance the upward airflow, with an optimal inclination of 20° increasing power generation by 10–35% relative to a conventional configuration. However, strong crosswinds of 12 m s−1 reduced the output by 55%, although increasing the collector slope partially mitigated this reduction. Fallah et al. [44] performed numerical simulations of a small-scale inclined plant and concluded that the steady-state assumption was acceptable for solar irradiance levels exceeding 600 W m−2.
Experimental measurements remain limited to small-scale prototypes. Kalash et al. [45,46] constructed a pilot inclined plant at Damascus University and monitored the glass, air, and absorber temperatures along the collector, together with solar irradiance, ambient temperature, and chimney air velocity, at 10 min intervals throughout 2012. They observed that the temperature difference between the chimney inlet and the ambient atmosphere remained nearly constant between winter and summer, which they considered a beneficial characteristic of the inclined collector. Guzel et al. [47] experimentally evaluated a micro-scale inclined plant incorporating an 8 m chimney and a 6.4 m collector. The system achieved a collector efficiency of 14.2%, with an air temperature increase of up to 2.4 °C.
Several studies have investigated solar chimney systems in Saudi Arabia and the Gulf region, while a recent review addresses research conducted in Iraq and Saudi Arabia [48]. Hamdan [49] examined a solar chimney plant in the Arabian Gulf region, whereas Abdelmohimen and Algarni [50] employed CFD simulations to investigate plant operation under Saudi climatic conditions. Hussain et al. [51] evaluated five locations in Saudi Arabia using monthly averaged K.A.CARE meteorological data and a 195 m chimney, while Hussain and Al-Sulaiman [52] conducted an exergy analysis of a plant operating under Saudi weather conditions. Focusing specifically on Abha, Alshahrani [53] applied an analytical model to investigate a plant utilizing the 2270 m elevation difference between sea level and the city. The study reported considerable seasonal variations in power output, with the lowest value occurring in November. However, none of these investigations considered a solar collector installed along the natural terrain.
Table 1 presents the existing studies on inclined solar chimney plants and provides a comparison with the current investigation. Three main observations from the reviewed literature establish the context for the present study. First, thermal models incorporating substantial collector slopes generally assume steady-state operation and rely on design-point or monthly averaged meteorological conditions. Similarly, most CFD investigations are based on steady-state simulations using geometries comparable to the 195 m Manzanares chimney. Consequently, these approaches do not explicitly resolve hourly weather variations or atmospheric stratification over elevation differences of several hundred meters. Second, experimental investigations remain restricted to small-scale prototypes [45,46,47], leaving large-scale inclined configurations without direct experimental validation. Third, none of the sloped-plant studies reviewed were conducted in the Arabian Peninsula, where the system would operate at high elevation under strongly stratified atmospheric conditions. The closest regional studies were conducted in southwestern Iran [54] and northern Iraq [42].
Table 1. Studies of sloped, inclined or mountain-based solar chimney plants cited in this paper. Details are taken from the original abstracts or from the cited reviews; not every paper was read in full.
Previous investigations have addressed chimney-height optimization and the influence of chimney geometry on power generation for conventional flat-ground plants [14,15]. Although the studies discussed above highlight the potential benefits of natural terrain, most consider a single geometry, location, or representative day or month. Except for Zhou et al. [23], who compared an inclined configuration with conventional chimneys of different heights, none of the reviewed studies quantified the advantage of collector inclination using a transferable measure applicable across different sites and system designs. One possible measure is the equivalent height of a conventional flat-ground chimney required to generate the same annual energy output.

1.2. Research Gaps and Contribution

The first research gap therefore concerns the applicability of the slope advantage across different locations. Existing studies present power output or efficiency for specific geometries and sites, rather than a general measure that can be applied to other terrains, such as the equivalent height of a flat-ground chimney required to produce the same annual energy output.
A second research gap relates to the thermodynamic behavior of tall solar chimney plants. As heated air rises through the atmosphere, it expands and cools at approximately the dry-adiabatic lapse rate (about 9.8 K per km), while the surrounding atmospheric temperature generally decreases at a lower rate (approximately 6.5 K per km in the standard atmosphere [67]). Consequently, the temperature difference between the rising air and its surroundings decreases with elevation under stable atmospheric conditions. Thus, each additional meter of chimney or inclined collector contributes progressively less driving pressure than the preceding meter. Detailed models incorporate this phenomenon [8,9,10,11,12] (see Section 1.1). However, preliminary assessment models frequently employ buoyancy formulations based on constant density or a constant temperature difference [13,15].
Compressible-flow models developed for inclined solar chimney plants [23,24,25] account for density variations with elevation and therefore implicitly represent this effect. Nevertheless, among the inclined-plant studies reviewed, we found no quantitative assessment of the error introduced by neglecting adiabatic cooling in the annual energy predictions of a slope-collector plant using a full year of measured meteorological data. Similarly, no sensitivity analysis was identified that evaluates the influence of the ambient atmospheric lapse rate using constraints derived from reanalysis data. These statements are limited to the records screened in Section 1.1.
A third research gap concerns the meteorological inputs used in performance predictions. Many previous investigations rely on design-point conditions or monthly averaged solar irradiance, although the annual energy generation of a plant operating with a variable pressure fraction depends on the complete hourly variations in solar irradiance, ambient temperature, and pressure. Reliable hourly meteorological measurements for Saudi Arabia are available through the K.A.CARE solar monitoring network [68]. Previous solar chimney investigations in Saudi Arabia include an assessment of five locations using monthly mean K.A.CARE data and a 195 m chimney [51], a study conducted for Dhahran [52], an investigation covering the Arabian Gulf region [49], and an analytical assessment of a plant extending between sea level and Abha [53]. However, none of the studies identified in this review considered a collector installed along a mountain slope or incorporated measured hourly meteorological data from the southwestern highlands, where the system would operate at high elevation under atmospheric conditions characterized by significant vertical stratification.
The present study aims to address these research gaps. Specifically, we (i) develop a one-dimensional thermo-hydraulic model of an inclined SCPP that incorporates dry-adiabatic cooling along both the inclined collector and the chimney and verify the model against analytical solutions; (ii) evaluate, using one year of hourly meteorological measurements from Abha, the extent to which neglecting adiabatic cooling leads to an overestimation of annual energy generation; (iii) introduce and calculate the equivalent chimney height associated with collector inclination; and (iv) determine the uncertain parameters that most strongly influence the predicted results through a global sensitivity analysis.
The compressible-flow models for inclined solar chimney plants presented by Zhou et al. [23,24] and von Allwörden et al. [25] provide the theoretical foundation for this investigation. The main contribution of the present work is not the development of an entirely new compressible-flow formulation, but rather its integration with a full-year simulation based on measured hourly meteorological data, the introduction of a transferable metric to quantify the benefit of terrain inclination, and the evaluation of the idealized slope representation using digital elevation and atmospheric reanalysis datasets. Section 2 presents the meteorological data, Section 3 describes the mathematical model, Section 4 provides its verification, Section 5 discusses the results, and Section 6, Section 7 and Section 8 address the discussion, limitations, and conclusions.
The specific contributions of this study relative to previous work are summarized as follows. (i) The compressible-flow models developed by Zhou et al. [23,24] and von Allwörden et al. [25] address generic geometries under steady or design-point conditions. In contrast, this study solves the collector–chimney pressure balance, including an explicit turbine pressure fraction, for each daylight hour of a measured year (4778 records), with the lapse rate checked against ERA5. (ii) The author’s previous analytical study of Abha [53] examined a plant utilizing the 2270 m elevation difference between sea level and the city, while the CFD study of Manzanares-scale slopes [41] considered a 0.6° collector slope. Here, the collector follows the terrain, represented by either an idealized cone or sector-averaged Copernicus DEM profiles, and the slope benefit is expressed in terms of equivalent chimney height. (iii) The role of adiabatic cooling is quantified using explicitly defined formulations (Section 3.5). Sensitivity analyses are conducted both with and without the turbine pressure fraction as an input. (iv) The limitations of the approach are quantified through comparison with a published CFD study of a sloped plant (Section 4.3). No new compressible-flow formulation is proposed.

2. Site and Data

2.1. Station and Period

Meteorological inputs were obtained from the K.A.CARE Renewable Resource Monitoring and Mapping (RRMM) station at Abha–TVTC (18.2227° N, 42.5460° E) [68]. The average station pressure of 786.7 hPa is consistent with an elevation of approximately 2.1–2.2 km above sea level. The available dataset extends from January 2021 through August 2022, while the selected analysis period spans 1 September 2021 to 31 August 2022, comprising 8760 hourly observations. The hourly variables considered include global horizontal irradiance (GHI), direct normal irradiance (DNI), diffuse horizontal irradiance (DHI), ambient air temperature, barometric pressure, relative humidity, and solar zenith and azimuth angles. Wind measurements are not included in the Abha dataset. Topographic information was obtained from the Copernicus GLO-30 digital elevation model, with a spatial resolution of 30 m [69] (Section 5.6). Data from a second monitoring station, Jazan University (16.9604° N, 42.5459° E; mean pressure of 1008 hPa), were used exclusively to estimate the inter-station surface temperature lapse rate (Section 3.3). Figure 1 illustrates the locations of both stations and the surrounding topography of Abha. The Abha–TVTC station is situated along the crest of the Sarawat Mountains at an elevation of 2167 m, based on the corresponding Copernicus DEM grid cell. Along an azimuth of 255°, the terrain rises to approximately 2600 m at a distance of about 10 km from the station before descending to nearly 1400 m over the following 10 km. In comparison, Jazan University is located approximately 140 km south of Abha, near sea level.

2.2. Time Convention and Quality Control

All timestamps are expressed in local time (UTC+3). To verify the time convention, the solar position was calculated using a low-precision astronomical algorithm [70] at each timestamp and compared with the zenith and azimuth angles provided in the dataset for the 6628 observations with solar zenith angles below 85° from the full dataset (January 2021–August 2022; 14,592 hourly records). The closest agreement was obtained when the solar position was calculated at the midpoint of each hour, corresponding to the recorded timestamp plus 30 min. The mean absolute differences were 0.14° for the zenith angle and 1.6° for the azimuth angle, whereas other half-hour shifts resulted in differences of at least 5.8°. Therefore, the reported solar angles represent mid-interval values and were treated accordingly. This approach eliminates the timestamp uncertainty that could otherwise influence the sunrise and sunset periods. A weather record was considered valid when GHI, air temperature, and pressure had finite values, GHI was non-negative, the temperature ranged from −35 to 65 °C, and the pressure ranged from 600 to 1100 hPa. Of the 8760 hourly observations, 8759 satisfied these criteria, including 3980 records with zero GHI and 4779 daylight records (GHI > 0). The daylight records also include hours with partial solar illumination around sunrise and sunset, explaining why the average number of daylight hours per day (13.1) is greater than the astronomical day length. For the 4065 observations with zenith angles below 85° during the analysis year, positive GHI, and complete measurements of all three irradiance components, the irradiance closure error, defined as GHI − (DHI + DNI cos θz), had a mean value of 1.2 W m−2, a mean absolute error of 2.1 W m−2 (equivalent to 0.40% of the mean GHI), and a root mean square (RMS) value of 3.5 W m−2.

2.3. Gap Filling by Closure

Among the 4779 daylight hours, 4669 contain complete DNI and DHI measurements. For the remaining 110 h (70 in June, 28 in July, and 12 in December), one of the two components is unavailable: DHI is missing in 98 h and DNI in 12 h, whereas GHI and the solar angles are available for all these records. Since the irradiance closure relationship is satisfied with an RMS error of approximately 3.5 W m−2, the missing component is estimated using the other two irradiance components:
D h = G h − D n cos θ z ,     D n = G h − D h cos θ z
where Gh, Dn and Dh represent GHI, DNI, and DHI, respectively. The value of Dn is restricted to the range of 0–1200 W m−2, and reconstruction is not performed when cos θz < 0.05. This procedure successfully reconstructs 109 of the 110 missing records, while one hour corresponding to the sun near the horizon remains unfilled, resulting in 4778 daylight records evaluated by the model. Statistical decomposition methods provide a less accurate alternative. An Erbs-type model [71], evaluated using the valid observations, produced RMS errors of 123 W m−2 for DHI and 320 W m−2 for DNI, compared with approximately 3.5 W m−2 for the irradiance closure approach. Excluding the reconstructed records and using only the 4669 complete hours reduces the annual energy generation of the reference configuration by 2.3% (341.7 versus 349.6 GWh).

2.4. Annual Climate of the Analysis Year

Table 2 presents a summary of the meteorological data. The annual GHI reaches 2187 kWh m−2, including 766 kWh m−2 of diffuse irradiation, while the annual DNI is 2090 kWh m−2. The average air temperature is 18.9 °C, varying between 4.5 and 31.8 °C, with a mean relative humidity of 42%. Figure 2a illustrates the hourly distribution of GHI. Solar irradiance exceeding 20 W m−2 is observed between 06:00 and 19:00 local time. The midday irradiation pattern remains relatively consistent from autumn through spring, reaching a peak of 1236 W m−2. However, from approximately mid-June onward (day 285 of the dataset), this pattern becomes more irregular, indicating increased afternoon cloud cover during summer. Figure 2b presents the monthly irradiation totals. GHI reaches its highest levels during March–May (214–220 kWh m−2) and its lowest values in December and January (161 and 147 kWh m−2, respectively). DNI is greater than GHI between October and March, reaching up to 242 kWh m−2 in December. This difference arises because DNI is measured perpendicular to the incoming solar beam, which forms a larger angle with the horizontal surface during winter. Diffuse irradiation reaches its maximum during June–August (93–115 kWh m−2), corresponding to the period of greatest cloudiness over the escarpment. These seasonal variations influence the monthly energy generation of the plant, as discussed in Section 5.1. Compared with the long-term estimates provided by the Global Solar Atlas [2] for Abha (18.2164° N, 42.5053° E; version 2.13, accessed 24 October 2026), which report annual values of 2268 kWh m−2 for GHI, 2208 kWh m−2 for DNI, and 762 kWh m−2 for diffuse irradiation, the selected analysis year exhibits 3.6% lower GHI and 5.3% lower DNI, while diffuse irradiation remains nearly unchanged. Adjusting the three irradiation components to match the long-term values increases the predicted annual energy generation of the reference configuration from 349.6 to 365.6 GWh (+4.6%). This suggests that the selected analysis year provides a slightly conservative estimate of energy generation relative to long-term irradiation conditions. Nevertheless, the Global Solar Atlas is based on satellite-derived estimates that carry their own uncertainties, and this comparison cannot substitute for simulations using meteorological data from multiple years.
Table 2. Data coverage and annual statistics of the Abha–TVTC record, 1 September 2021–31 August 2022.
Figure 2. Meteorological forcing at Abha–TVTC for 1 September 2021–31 August 2022. (a) Hourly GHI by month and local hour (04–20 h shown; GHI is zero outside this window; one missing night hour, 27 June 2022 02:00, is not visible). (b) Monthly irradiation, with annual totals in the legend.

3. Model

3.1. Configuration and Assumptions

Symbols are introduced at their first occurrence and are summarized in the Nomenclature and Abbreviations section. The plant configuration (Figure 3) consists of a sector-shaped collector with an opening angle φ, extending between the plan radii Ri and Ro, measured from the chimney axis. The collector is positioned on a conical slope with an inclination angle β and covered by a transparent roof maintaining a constant clearance height h above the ground. Air enters through the lower rim, moves radially inward and upward along the slope, and then flows into a vertical chimney of height Hc and diameter D, located at the upper end of the slope. The terrain elevation gain is represented by Hs, resulting in a total vertical height of Hs + Hc. Figure 3a illustrates the side view, indicating Hs, Hc, and the air inlet at the lower rim, while Figure 3b presents the front view facing uphill. Figure 3c displays the plan view, including the opening angle φ and the radii Ri and Ro. The plan area Ah, roof area Ar, slope length Ls, and vertical rise are expressed as follows:
A h = φ 2 R o 2 − R i 2 ,   A r = A h cos β ,   L s = R o − R i cos β ,   H s = R o − R i tan β
Figure 3. Configuration of the inclined solar chimney power plant. (a) Side view (not to scale): The collector roof lies parallel to the slope, the turbine is at the chimney base, and the chimney stands at the top; the inlet state is the station state extrapolated downwards with the lapse rate. (b) Front view looking uphill. (c) Plan view of the collector sector.
In the baseline configurations, the terrain is represented by an idealized conical surface with a uniform inclination angle in all azimuthal directions within the collector sector. This assumption provides an upper-bound approximation for a planar escarpment, since the elevation gain along directions deviating from the steepest slope is smaller. The implications of this simplification are examined in Section 5.6, where the conical representation is also replaced with sector-averaged terrain profiles obtained from a digital elevation model. For the baseline configurations, β is treated as a design parameter, while the Abha meteorological dataset is used to define the atmospheric conditions for the idealized escarpment plant.
The following assumptions are adopted in the model:
  • Quasi-steady, one-dimensional airflow is evaluated separately for each hour, neglecting ground thermal storage and transient effects.
  • Dry air is treated as an ideal gas with a constant specific heat capacity cp.
  • Ambient atmospheric conditions follow a standard-atmosphere model with a constant temperature lapse rate Γ and hydrostatic pressure distribution.
  • The overall heat-loss coefficients Ucol for the collector roof and Uch for the chimney wall are assumed constant, together with an effective optical efficiency ηopt representing the transmittance–absorptance product, including solar absorption by the ground.
  • Frictional and local loss coefficients are assumed constant, as is the turbine–generator efficiency ηTG.
  • The turbine operates at a specified pressure fraction λ = Δpt/Δpb.

3.2. Irradiance on the Collector

Solar irradiance incident on the collector roof is calculated using measured DNI and DHI based on an isotropic-sky model [72,73]. To represent the conical surface, the direct beam component is averaged across Naz = 13 azimuthal directions distributed over the collector sector, each with an inclination angle β:
G POA = D n   max cos θ i , 0 ¯ + D h 1 + cos β 2 + ρ g G h 1 − cos β 2 ,   cos θ i = cos θ z cos β + sin θ z sin β cos γ s − γ p
where γs represents the solar azimuth, γp denotes the azimuth of the collector roof normal, and ρg = 0.20 is the ground albedo. In the reference configuration, the collector sector is oriented toward the south, while eastward and westward orientations are examined in the sensitivity analysis. The model does not explicitly account for horizon shading from the surrounding terrain; however, its potential impact is bounded for the DEM-based sectors in Section 5.6.

3.3. Ambient Atmosphere and Anchoring

The ambient temperature and pressure profiles are
T a z = T in − Γ z ,     p a z = p in T a z T in g / R Γ
where z denotes the elevation relative to the collector inlet. The Abha station is assumed to represent the ambient atmospheric conditions at the elevation of the reference plant’s chimney outlet (z = Href = Hs + Hc = 1917 m). Accordingly, the inlet conditions are determined from the station temperature Tst and pressure pst using Tin = Tst + ΓHref and pin = pst(Tin/Tst)g/(RΓ). The same inlet conditions are applied to all configurations within each comparison, ensuring that the observed differences result solely from geometric variations. The effect of this assumption is examined in Section 5.5, while Table 3 provides the absolute elevations of the collector inlet, chimney base, and chimney outlet for all configurations (Table 4). The reference temperature lapse rate is set to the standard-atmosphere value of Γ = 6.5 K km−1 [67]. To provide an empirical assessment based on the temperature difference between the Abha and Jazan stations, an effective surface lapse rate was also calculated as Γeff = (TJ − TA)/Δz, where Δz was obtained using the hypsometric equation (mean Δ*z* = 2160 m). The hourly median value is 4.0 K km−1 around midday and 6.0–6.2 K km−1 during nighttime, with an annual mean of 5.3 K km−1 and a 5–95th percentile range of 3.0–7.3 K km−1. Since this estimate is based on surface measurements at two stations separated by 140 km, it does not represent the vertical temperature profile of the free atmosphere. Therefore, it is considered only as a low-lapse-rate scenario, while the free-atmosphere lapse rate derived from reanalysis data is investigated separately in Section 5.5.
Table 3. Absolute elevations (m above sea level) of the collector inlet, chimney base, and chimney outlet (Hc = 1000 m) for the idealized cone, the two alternative anchoring cases discussed in Section 5.5, and the DEM sectors examined in Table 4.
Table 4. Collector sectors selected from the digital elevation model and their annual output at λ = 0.8 (measured Abha weather; sector-mean ground profile; ambient state at the inlet derived from the station at the rim elevation).
The ERA5 pressure levels correspond to the following annual-mean geopotential heights, averaged over the 7 × 7 grid cells: 1504 m at 850 hPa, 2027 m at 800 hPa, 2580 m at 750 hPa, 3162 m at 700 hPa, 3777 m at 650 hPa, and 4430 m at 600 hPa. With the station located at an elevation of 2165 m, the 850 and 800 hPa levels lie below the station elevation in all hours, whereas the 750 hPa level and all higher levels remain above it. Consequently, the reference lapse-rate layer (850–650 hPa) includes grid-cell values that lie below the local ground. To exclude them, ERA5 surface pressure and surface geopotential were retrieved for the same grid and period, and a pressure level was treated as below ground in a given cell and hour when its pressure exceeded the surface pressure (a geopotential height below the surface height gave the same result). By this criterion, the 850 hPa level is below ground in 33% of all cell-hours and the 800 hPa level in 5.8%, whereas no cell-hour is affected at 750 hPa or above. The lapse rate of each layer was computed cell by cell and averaged over the valid cells only; on average, 33 of the 49 cells were retained for the 850–650 hPa layer. The effect of this exclusion is reported in Section 5.5, together with results for pressure layers located entirely above the station elevation (750–650 and 750–600 hPa).

3.4. Collector

Let θ = T − Ta represent the temperature difference between the airflow and the surrounding atmosphere at the same elevation. For a mass flow rate ṁ, the energy balance along the collector roof area A, extending from the inlet rim to the throat at Ri, is expressed as follows:
m ˙ c p d θ dA = η opt G POA − U col   θ − m ˙ c p κ c − Γ dz dA
The final term represents the change in excess temperature resulting from an elevation change dz. The internal air cools with elevation at a rate of κc, while the ambient air cools at a rate of Γ. Therefore, the excess temperature θ changes by −(κc − Γ)dz. In the full formulation, κc = g/cp represents the dry-adiabatic lapse rate (9.76 K km−1). The coefficient κc is introduced to ensure that all formulations compared in Section 5.2 can be derived from the same governing equations, as described in Section 3.5. Equation (5) is integrated numerically across n radial cells, with the heating and heat-loss contributions solved analytically within each cell,
θ k + 1 = θ k e − a k + η opt G POA U col 1 − e − a k − g c p − Γ Δ z k ,     a k = U col Δ A k m ˙ c p
where ΔAk = φ rm Δr/cos β represents the roof area of each cell, with θ = 0 at the collector inlet. When κc = Γ (no adiabatic term) and GPOA is assumed constant, the marching solution simplifies to the closed-form expression for the collector: θout = (ηoptGPOA/Ucol)(1 − e−NTU), NTU = UcolAr/(ṁcp). This analytical solution is used in Section 4.

3.5. Chimney

In the chimney (z from Hs to Hs + Hc) the excess temperature obeys
d θ dz = − U ch π D m ˙ c p θ + Γ − κ h
The solution for each cell follows a similar approach to Equation (6). When wall heat losses are negligible, θ decreases linearly with elevation at a rate of (κh − Γ), which is g/cp − Γ = 3.26 K km−1 in the full formulation. This effect explains why the additional benefit of increasing the height gradually diminishes.
Three formulations are compared in Section 5.2, each representing a special case of Equations (5) and (7) defined by the coefficient pair (κc, κh). The first is the full formulation, where κc = κh = g/cp, and the internal air undergoes dry-adiabatic cooling in both the collector and the chimney. This formulation is used throughout the study, except in the comparative analysis presented in Section 5.2. The second considers adiabatic cooling in the chimney only, with κc = Γ and κh = g/cp. The third neglects the adiabatic term and assumes constant excess temperature, with κc = κh = Γ. In this case, the term (κ − Γ)dz vanishes, the internal air cools at the same rate as the ambient air, and the excess temperature θ changes only due to heating and wall losses. This formulation is the numerical equivalent of the constant-temperature-excess buoyancy assumption adopted in simplified models [13,15]. Under these conditions, Equations (5) and (7) reduce to
m ˙ c p d θ dA = η opt G POA − U col   θ
d θ dz = − U ch π D m ˙ c p θ
A simplified hybrid formulation, with κc = Γ and κh = 0 (constant excess temperature in the collector and isothermal air in the chimney), is included in Table 5 for transparency only. Under this assumption, the excess temperature increases at a rate of Γ with elevation along the chimney. Therefore, this formulation does not provide a consistent basis for comparison with the full model and is excluded from the quantitative conclusions presented in this study.
Table 5. Annual energy (GWh) for three thermodynamic formulations at different turbine pressure fractions. The hybrid row (κc = Γ, κh = 0) is shown for transparency only.

3.6. Buoyancy and Pressure Losses

The internal air temperature is expressed as Th = Ta + θ, assuming the ambient pressure at the corresponding elevation, since the pressure difference between the internal and external air is small relative to p. The driving pressure is then determined by integrating the hydrostatic pressure difference over the entire vertical elevation range,
Δ p b = ∫ 0 H s + H c g ρ a − ρ h dz ,     ρ = p RT
The pressure losses include collector losses (wall friction, with a hydraulic diameter of 2h, and inlet losses), flow-turning losses at the throat, frictional losses along the chimney walls, and outlet losses,
Δ p loss = ∫ f c 2 h ρ v 2 2 dx + K in ρ i v i 2 2 + K turn ρ t v t 2 2 + ∫ f ch D m ˙ 2 2 ρ A ch 2 dz + K exit m ˙ 2 2 ρ e A ch 2
where vt represents the airflow velocity at the collector throat (the cross-sectional area at Ri), which serves as the reference for defining Kturn. The densities correspond to those of the air flowing inside the system.

3.7. Turbine and Solution

A fraction λ of the available driving pressure is utilized by the turbine. The mass flow rate is determined by solving the pressure balance equation, while the electrical power output is calculated from the pressure drop across the turbine and the volumetric flow rate:
1 − λ   Δ p b ( m ˙ ) = Δ p loss ( m ˙ ) ,     P = η TG   λ   Δ p b   m ˙ ρ ch , 0
where ρch,0 represents the air density at the base of the chimney. The root is determined using a bracketing method followed by 40 bisection iterations for each hour, with the calculations vectorized across all hourly records. Hours for which no positive root exists, indicating that the buoyancy-driven pressure is insufficient to overcome the flow resistance at any mass flow rate, are classified as no-flow hours and assigned zero power output. These conditions represent a physical outcome rather than a numerical convergence failure.

3.8. Performance Metrics

The annual energy generation is calculated as E = Σ PiΔt, where Δt = 1 h. The overall system efficiency is defined as the ratio of the annual energy output E to the total solar irradiation incident on the collector roof,
η sys = E A r ∑ i G POA , i Δ t
The equivalent chimney height of an inclined collector is defined as the chimney height Heq required for a flat-ground plant with identical collector plan geometry, gap height, turbine loading, and inlet conditions to generate the same annual energy as the inclined configuration without a chimney,
E flat H eq = E incl β , H c = 0
For configurations with a vertical chimney, the equivalent-height ratio is defined as r = (Htot − Hc)/Hs, where Htot is the height of a flat-ground chimney producing the same annual energy as the inclined configuration. This definition reduces to Heq/Hs when Hc = 0. For the full formulation, the annual energy balance presented in Section 5.1 separates the incident solar irradiation into absorbed heat, Qabs = ηopt Σ GPOAArΔt; heat transferred to the airflow, Qair = Σ ṁcp[θcol + (g/cp − Γ)Hs]Δt; heat losses through the chimney walls, Qwall = Σ ṁcp[θcol − θtop + (Γ − g/cp)Hc]Δt; and buoyancy work, Wb = Σ Δpb(ṁ/ρch,0)Δt. Here, θcol and θtop represent the temperature differences between the internal air and the surrounding atmosphere at the collector throat and chimney outlet, respectively. According to the pressure balance in Equation (10), Wb is distributed between hydraulic losses, (1 − λ)Wb, and turbine work, λWb, with a fraction ηTG of the latter converted into electrical energy. The remaining unconverted heat is expressed as Qair − Qwall − Wb. This quantity includes the thermal energy discharged with the exhaust airflow and the work associated with gravity and expansion. It represents a residual term in the energy balance rather than an independently measured heat loss. The equivalent-height ratio indicates the effectiveness of the terrain elevation gain in replacing the height of a conventional chimney. The annual energy output Eflat is calculated for chimney heights of Hc = 250, 500, 750, and 1000 m, with intermediate values obtained through interpolation. Equivalent heights exceeding 1000 m are estimated using linear extrapolation and are explicitly identified as extrapolated results.

3.9. Reference Case and Sensitivity Design

The reference plant configuration is presented in Table 6. The collector opening angle, inner and outer radii, inclination angle, chimney dimensions, and collector gap result in a roof area of 21.4 km2, a terrain elevation gain of 917 m, and a chimney with a height of 1000 m and a diameter of 300 m, placing it among the largest proposed designs. The reference turbine pressure fraction λ = 0.8 represents a specified operating condition within the broad plateau of the energy-loading curve (Section 5.3), rather than a calibrated parameter. Turbine loading is examined independently, and the optimal constant value of λ for each configuration is also presented as an upper-bound estimate. A global sensitivity analysis is performed using Latin hypercube sampling [74], comprising 360 parameter combinations selected from the parameter ranges detailed in Section 5.8. Each combination is evaluated at every eighth operating hour (598 h). The estimated annual energy for the reference configuration is 352.3 GWh, compared with 349.6 GWh obtained using all hourly records, corresponding to a sampling error of 0.8%. All parameters are sampled from uniform, independent distributions over the ranges of Table 7, without imposed correlations. A second analysis at a fixed λ = 0.8 (720 samples) is described in Section 5.8. The influence of individual parameters is assessed using the standardized rank regression coefficient (SRRC) and the partial rank correlation coefficient (PRCC) [75,76].
Table 6. Reference configuration and parameters.
Table 7. Parameter ranges and sensitivity indices of the Latin hypercube analysis (360 samples). The last column is the SRRC of a separate analysis at fixed λ = 0.8 (720 samples).

4. Verification and Consistency Checks

The assessments presented in this section verify the numerical solution and evaluate its agreement with analytical limiting cases, a previously published flat-ground plant, and a published CFD investigation of a small-scale inclined plant. However, these comparisons do not constitute experimental validation of the large-scale inclined configuration. Since no published experimental measurements were identified for a plant of comparable scale, the main quantitative findings presented in Section 5 remain predictions based on the numerical model.

4.1. Numerical Verification

Table 8 presents the numerical verification tests. (i) When the adiabatic term is neglected and uniform solar irradiance is assumed, the marching solution for the collector agrees with the closed-form NTU solution, with a relative error of 5.8 × 10−16. (ii) Under negligible chimney wall heat losses, the numerical solution reproduces the analytical excess temperature θ0 + (Γ − g/cp)Hc with an absolute difference of 1.7 × 10−10 K. (iii) The buoyancy integral evaluated using 61 nodes deviates by only 0.07% from the result obtained with 2001 nodes. (iv) The calculated annual energy generation for n = 31, 61, 121, and 241 cells is 349.32, 349.60, 349.73, and 349.80 GWh, respectively. The reference grid with n = 61 differs from the finest grid by 0.06%. (v) At the converged mass flow rate, the residual of the pressure balance equation is below 4 × 10−10 Pa. These verification tests confirm the numerical consistency of the implemented equations but do not demonstrate their ability to accurately represent the behavior of an actual solar chimney plant.
Table 8. Numerical verification results.

4.2. Plausibility Check Against the Manzanares Plant

No experimental measurements are available for large-scale inclined solar chimney plants, and the datasets from small-scale prototypes [45,46,47] were not accessible to us. Therefore, direct validation of the inclined configuration could not be performed. To evaluate the consistency of the flat-ground component of the model, the Manzanares geometry was simulated using a collector radius of 122 m, a roof clearance increasing from 1.85 m at the outer rim to 6 m near the chimney, and a chimney height and diameter of 194.6 m and 10.16 m, respectively [3,4]. The simulations were conducted at a solar irradiance of 1000 W m−2, an ambient temperature of 303 K, an atmospheric pressure of 94 kPa, and a lapse rate of Γ = 6.5 K km−1. The model parameters were not calibrated against the prototype data. Instead, effective optical efficiency ηopt = 0.5–0.7 and collector heat-loss coefficient Ucol = 5–12 W m−2 K−1 were examined as plausible ranges for a ground-absorbing collector. Selected combinations are presented in Table 9, while the nominal prototype parameters are provided in Table 10. For turbine pressure fractions λ = 0.5–0.67, the model predicts a collector temperature increase of 22–28 K and electrical power output of 40–63 kW (ηopt = 0.5–0.6, Ucol = 8–12 W m−2 K−1). These results bracket the commonly reported nominal temperature rise of 20 K and power output of 50 kW for the Manzanares prototype [3,4], as well as the reference power output of approximately 46 kW obtained in a recent three-dimensional CFD investigation [41]. The predicted collector temperature rise is slightly higher than the reported nominal value, which is consistent with the simplified steady-state formulation that excludes ground thermal storage and off-design turbine losses. Since the upward airflow velocity depends on turbine operating conditions, the comparison is restricted to the unloaded configuration. With the turbine removed (λ = 0), the same parameter ranges predict a chimney air velocity of 11.8–13.8 m s−1 and a collector temperature increase of 18–25 K at an irradiance of 1000 W m−2. These values are compared with the maximum updraft velocity of approximately 15 m s−1 reported for the Manzanares plant [4], as cited in a secondary source. The present model consequently underpredicts the free-flow velocity by approximately 8–20%. The specific reason for this discrepancy was not determined, although possible contributing factors include the assumed optical efficiency, pressure-loss coefficients, and loss formulation. For the same flat-ground configuration, a published CFD analysis of a Manzanares-scale plant operating at 1000 W m−2 in Lanzhou reported a turbine pressure drop of 68.5 Pa [29]. Under λ = 0.5, the present model predicts a pressure drop of 70–82 Pa for ηopt = 0.5–0.6 and Ucol = 8–12 W m−2 K−1, using ambient temperatures of 293–300 K and a pressure of 84.5 kPa. However, the precise atmospheric conditions and turbine operating point adopted in the CFD investigation were unavailable, so the apparent agreement should be regarded as indicative rather than conclusive. The same study reported a pressure drop of 112.7 Pa for an inclined collector, but the corresponding slope geometry could not be reconstructed from the published description; therefore, no direct comparison was attempted. Overall, these comparisons provide an order-of-magnitude consistency assessment rather than experimental validation of the model. The published reference values should also be verified against the original data tables before being used as definitive benchmarks.
Table 9. Manzanares plausibility check (1000 W m−2, 303 K, 94 kPa, Γ = 6.5 K km−1).
Table 10. Reference nominal values of the Manzanares plant used for comparison [3,4].

4.3. Comparison with a Published CFD Study of a Sloped Plant

Cao et al. [29] performed CFD simulations of a Manzanares-scale solar chimney plant incorporating an inclined collector (31° inclination, 193.5 m collector elevation gain, and a collector area of 46,759.5 m2, identical to that of the horizontal reference configuration) under a solar irradiance of 1000 W m−2. They reported turbine pressure drops of 42.8, 62.1, and 112.7 Pa for chimney heights of 60, 98, and 194.6 m, respectively, compared with 68.5 Pa for the conventional flat-ground plant with a 194.6 m chimney (Table 8 of their study). The authors related the pressure difference to Hchi + Hcol/2, implying that the inclined collector contributes an effective height equivalent to half its vertical rise. However, the study does not specify the collector sector angle, roof clearance, ambient pressure or temperature profile, or turbine efficiency. Accordingly, we adopted a sector angle of 42.9° to obtain a collector roof area of 46,759.5 m2, the Manzanares collector gaps, and atmospheric conditions of 293 K and 84.5 kPa with Γ = 6.5 K km−1. The optical efficiency and collector heat-loss coefficient were assumed to range from ηopt = 0.5–0.6 and Ucol = 8–12 W m−2 K−1, respectively, in accordance with the values discussed in Section 4.2. Table 11 distinguishes between the conditions reported in Ref. [29] and those assumed in the present study, and presents the corresponding model predictions.
Table 11. Benchmark against the CFD study of Cao et al. [29]: the conditions reported in the source, the conditions assumed here, and the results.
Under these assumptions, the model captures the qualitative trends, showing an increase in pressure with both chimney height and collector inclination, but does not reproduce the reported magnitudes. At λ = 0.67, the predicted ratios of turbine pressure drop for the inclined plant relative to the horizontal configuration are 1.7, 2.0, and 2.5 for the three chimney heights, compared with 0.62, 0.91, and 1.65 obtained from the CFD results. When expressed in terms of the equivalent chimney height contributed by the inclined collector, the model predicts 0.91–1.06 times the terrain elevation gain for this geometry, considering sector angles of 43–360°, ambient temperatures of 283–293 K, and the two optical-efficiency and heat-loss settings described above. In comparison, the CFD pressure results correspond to equivalent-height ratios of 0.32, 0.41, and 0.65 for the respective chimney heights, assuming that the pressure difference scales linearly with effective height. The parameter variations examined did not resolve this discrepancy, and no model parameter was adjusted to match the CFD results.
The equivalent-height ratios predicted by the model are based on power or energy output, whereas those inferred from CFD results are derived from turbine pressure drops. To examine whether the choice of performance metric accounts for this difference, the model ratio was also calculated using the turbine pressure drop. In this approach, the equivalent height is defined as the height of a flat-ground chimney that produces the same turbine pressure drop as the inclined plant. The comparison was performed for the benchmark geometry (ηopt = 0.6, Ucol = 8 W m−2 K−1, and 293 K). For λ = 0.5–0.67 and sector angles ranging from 43° to 360°, the pressure-based ratio ranges from 0.82 to 0.93, compared with 0.88–1.05 for the power-based ratio. This difference arises because the inclined and flat-ground plants have different mass flow rates at the same chimney height. Both ranges remain considerably higher than the CFD-implied values of 0.32–0.65, indicating that the choice between pressure-based and energy-based definitions cannot explain the discrepancy.
Additional parametric calculations were conducted by varying the optical efficiency from 0.3 to 0.6, the collector roof heat-loss coefficient from 8 to 30 W m−2 K−1, and the uniform roof clearance from 2 to 15 m. The predicted inclined-to-horizontal turbine pressure ratio remained between 1.2 and 2.0 for the 60 m chimney and between 1.9 and 3.0 for the 194.6 m chimney. These values consistently exceeded the corresponding CFD ratios of 0.62 and 1.65. Neglecting the adiabatic terms altered the pressure ratios by less than 2%. Several factors may contribute to the discrepancy, although none of them can be confirmed with the available information. First, the one-dimensional model represents the flow by cross-sectional averages, whereas the CFD solution resolves three-dimensional flow; the recirculation region reported near the collector–chimney junction, and possibly flow separation or vortices inside the inclined collector, cannot be represented in a one-dimensional formulation and may alter the effective driving pressure. Second, the definition of the turbine pressure drop, the turbine characteristic, and the resulting mass flow rate may differ between the two studies, since the turbine pressure fraction and efficiency are not reported in the source. Third, the ambient profile and boundary conditions that are not reported in the CFD study were replaced by assumed values (Table 11), so the operating conditions of the two studies may differ. By contrast, variations in optical efficiency, roof heat-loss coefficient, and roof clearance did not close the gap, as shown above. These explanations are possibilities rather than demonstrated causes, and quantifying their individual contributions would require three-dimensional CFD simulations or measurements for the same configuration.
Consequently, the equivalent-height ratios of 0.71–0.79 for the chimney-free plant reported in Section 5.4 should be interpreted as predictions of the one-dimensional model and may represent an upper-bound estimate. Further confirmation through CFD simulations or experimental measurements is required before these values can be applied to practical design. To assess the implications of this model-form uncertainty, the annual energy generation of the reference plant with a 12.95° collector inclination was estimated using an equivalent horizontal-collector configuration with a chimney height of Hc + rHs. Three values of r = 0.32, 0.5, and 0.65 were considered, representing the range inferred from the CFD results, with λ = 0.8.
The additive expression Hc + rHs assumes that the contribution of the slope can be represented by a fixed equivalent-height ratio, independent of chimney height. However, the equivalent-height ratio varies with chimney height in the present model. For the 12.95° inclined plant, the flat-ground chimney heights required to reproduce the same energy output are 663, 931, 1203, 1482, and 1770 m for Hc = 0, 250, 500, 750, and 1000 m, respectively (the values above 1000 m are obtained by linear extrapolation). These correspond to equivalent-height ratios of r = (Htot − Hc)/Hs = 0.72, 0.74, 0.77, 0.80, and 0.84. Although the additional energy gained from the slope decreases as chimney height increases, from 154 GWh without a chimney to 125 GWh with a 1000 m chimney, the flat-ground energy curve approaches saturation more rapidly, causing the equivalent-height ratio to increase. Consequently, applying the chimney-free ratio of r = 0.72 to the 1000 m chimney would underestimate the inclined plant’s annual energy production by approximately 4% (about 335 GWh compared with 350 GWh). The error introduced by the additive approximation is therefore relatively small within the model and considerably lower than the 7–20% variation associated with the CFD-implied ratios. Accordingly, the energy estimates presented below (278, 305, and 326 GWh) should be interpreted as illustrative scenarios obtained by applying the CFD-implied ratios within the model, rather than as a validated correction.
For a chimney height of 1000 m, the resulting annual energy generation is 278, 305, and 326 GWh, respectively, compared with approximately 350 GWh predicted by the one-dimensional model. Reducing the chimney height to 500 m gives annual energy outputs of 182, 216, and 243 GWh, compared with 262 GWh from the one-dimensional formulation. For the configuration without a chimney, the corresponding values are 67, 107, and 139 GWh, compared with 154 GWh predicted by the model. These comparisons suggest that the one-dimensional predictions represent the upper portion of a possible range, with annual energy generation approximately 7–20% lower for the 1000 m chimney configuration if the CFD-based equivalence is applicable. The complete set of input parameters used by Zhou et al. [23], including the ambient atmospheric profile, solar irradiance, loss coefficients, and turbine loading, was not available. Consequently, their plant could not be reproduced under equivalent operating conditions, and a direct comparison with a published compressible-flow model remains an area for future investigation (Section 7).
A previously published compressible-flow model of a large inclined-collector plant [23], comprising a collector with an elevation gain of 848 m and a vertical chimney of 123 m, placed its predicted performance between those of conventional horizontal-collector plants with chimney heights of 547 and 971 m. These correspond to approximately 0.56–1.0 times the total elevation of 971 m. This interval includes the equivalent-height ratios of 0.71–0.79 obtained in the present study and overlaps with the upper portion of the range inferred from the CFD results. Nevertheless, the interval is too broad to establish which prediction is more accurate.

4.4. Data-Related Consistency Checks

Two verification checks were conducted to assess the meteorological inputs. First, the average power output per operating hour was 70.5 MW during January–August 2021 and 71.1 MW during January–August 2022, representing a difference of 0.8%. This suggests that the specific energy yield remained relatively consistent across the two periods. However, only 5096 of the 5832 weather records were valid for the 2021 period, making a direct comparison of total energy generation inappropriate. These checks are based on only 20 months of recorded data and cannot substitute for a multi-year analysis. Consequently, the interannual variability in energy yield remains unquantified (Section 7). Second, the data gap-filling procedure described in Section 2.3 affects the predicted annual energy generation by 2.3%, indicating that the main conclusions are not strongly influenced by this procedure.

5. Results

5.1. Reference Case

The reference plant configuration generates 349.6 GWh annually, with a maximum power output of 214 MW (204 MW using measured components only) (Table 12). The total solar irradiation incident on the collector roof amounts to 48,196 GWh, corresponding to an overall efficiency of 0.73%. The model is evaluated using 4778 daylight records with GHI > 0 after gap filling (Table 2). In 79 of these hours, low solar irradiance near sunrise and sunset produces insufficient buoyancy-driven pressure to overcome the system losses. Consequently, no positive-flow solution is obtained, and the power output is set to zero. The plant therefore generates non-zero power during 4699 h. The mean power output is 73.2 MW when calculated over all 4778 evaluated daylight records (349.6 GWh/4778 h), increasing to 74.4 MW when only the 4699 h with non-zero power are considered. At the hour of maximum power generation, the mass flow rate reaches 339 t s−1, the available driving pressure is 927 Pa, and the collector temperature increase is 20.1 K. The corresponding airflow velocities at the collector throat and inside the chimney are 17.2 and 5.1 m s−1, respectively. Monthly energy generation varies from 25 GWh in July and August to 35 GWh in March, following the seasonal irradiation pattern presented in Figure 2b. During spring (March–May), monthly energy production ranges from 33 to 35 GWh, exceeding the values recorded during the cloudier summer months (June–August, 25–27 GWh) by as much as 40% (Figure 4a). The daily power profile exhibits a single peak around midday. The seasonal average noon power reaches 167 MW during March–May, 154 MW during September–November, 146 MW during December–February, and 130 MW during June–August (Figure 4b). The power duration curve (Figure 4c) indicates that the plant generates non-zero power for approximately 54% of the year and exceeds 100 MW for 1799 h, representing 21% of the year. The ten highest hourly power outputs range from 185 to 214 MW, while the upper 1% of operating hours exceed 174 MW. The capacity factor of 19% is calculated using the maximum simulated hourly power of 214.1 MW as the reference capacity (349.6 GWh/(214.1 MW × 8760 h)), rather than an independently specified installed turbine rating. If the reference capacity is instead taken as the maximum power of 204 MW obtained using measured components only, the capacity factor increases to approximately 20%. The maximum-power hour (20 June 2022 at 12:00) corresponds to one of the reconstructed records, with GHI = 1236 W m−2 and a clearness index of 0.96. In comparison, the highest power predicted for records containing measured DNI and DHI is 204 MW. A clearness index of 0.96 may indicate either a cloud-enhancement event or a measurement artefact. Accordingly, the peak power of the reference plant is reported as 204 MW, based exclusively on measured components. The higher value of 214 MW obtained from the full simulated time series, which includes the reconstructed hour, is retained in the sensitivity analyses to ensure that all scenarios are evaluated using the same hourly dataset. As discussed in Section 2.3, the reconstructed records affect the estimated annual energy production by only a few percent.
Table 12. Reference-case results (λ = 0.8, full formulation).
Figure 4. Reference-case results (λ = 0.8). (a) Monthly energy. (b) Mean power by hour of day and season. (c) Power duration curve.
Figure 5 illustrates the energy distribution for the reference configuration. Of the total 48,196 GWh of solar energy incident on the collector roof, 16,869 GWh (35.0%) is absorbed, while 31,327 GWh (65.0%) is lost through optical processes. An additional 2609 GWh (5.4% of the incident energy) is transferred from the collector roof to the surrounding air, leaving 14,259 GWh (29.6%) carried by the rising airflow. Heat loss through the chimney walls is relatively small, amounting to only 65 GWh. The majority of the thermal energy remains unconverted and is discharged with the exhaust air, accounting for 13,713 GWh (28.5%) when the chimney wall losses are included. Consequently, only 546 GWh, equivalent to 1.13% of the incident solar energy and 3.8% of the heat transported by the airflow, is converted into buoyancy work. At a turbine pressure fraction of λ = 0.8, the pressure balance allocates 109 GWh of the available buoyancy work to hydraulic losses. An additional 87 GWh is lost through the turbine–generator conversion process, resulting in a net electrical energy output of 349.6 GWh (0.73% of the incident energy). The conversion efficiency from the heat carried by the airflow to buoyancy work is 3.8%, representing approximately 60% of the ideal limit, gH/(cpT) = 6.4%, for the total vertical height of 1917 m. The difference is mainly attributed to the reduction in excess air temperature with increasing elevation, as discussed in Section 5.2. These results indicate that optical and thermodynamic losses dominate the overall energy balance, rather than hydraulic or mechanical losses. The combined hydraulic and turbine–generator losses total approximately 197 GWh, corresponding to 0.41% of the incident solar energy. This finding agrees with the limited sensitivity to frictional and local loss coefficients reported in Section 5.8. The definitions of the individual energy balance terms are provided in Section 3.8.
Figure 5. Annual energy flow of the reference plant (λ = 0.8). (a) Components and loss paths. (b) Energy flow from the irradiation on the roof to the buoyancy work; band widths are proportional to the energy on a common scale, and each band ends in an arrow. (c) The turbine and generator stages, enlarged 49 times relative to (b) because the buoyancy work is only 1.1% of the irradiation. Values are annual sums in GWh, and percentages are of the irradiation incident on the roof (48,196 GWh). The optical efficiency (ηopt = 0.35), the turbine pressure fraction (λ = 0.8), and the turbine–generator efficiency (ηTG = 0.80) are inputs; the other values are results. “Unconverted heat and exhaust” is the heat carried by the air that remains after the chimney wall loss and the buoyancy work. The ideal conversion limit gH/(cpT) = 6.4% is for the total height of 1917 m and T = 292 K.

5.2. Effect of Adiabatic Cooling

Figure 6 shows the temperature distribution during the hour of maximum power output for which measured DNI and DHI data are available. Three formulations are compared, based on the coefficients κc and κh defined in Equations (5) and (7): a constant-excess model that neglects the adiabatic term (κc = κh = Γ), in which the internal air cools at the same rate as the ambient air; a formulation that considers adiabatic cooling in the chimney only (κc = Γ, κh = g/cp); and the full formulation, which accounts for dry-adiabatic cooling in both the collector and the chimney (κc = κh = g/cp). The constant-excess model is based on the constant-temperature-excess buoyancy assumption used in simplified models [13,15]. It does not represent any specific published implementation but is included as a reference case to assess the effect of adiabatic cooling. Therefore, the comparison represents a sensitivity assessment of the physical assumptions rather than a correction to any specific previous model. When the adiabatic term is neglected, the internal air cools at the same rate as the ambient air, maintaining an excess temperature of approximately 21 K along the chimney (21.3 K at the base and 21.2 K at the outlet). In contrast, including adiabatic cooling causes the excess temperature to decrease at a rate of approximately 3.3 K/km, reaching 16.3 K at the chimney outlet. The resulting buoyancy-driven pressure differences are 1004 and 896 Pa, respectively, representing an increase of approximately 12% when adiabatic cooling is neglected. Figure 6a illustrates the variation in ambient and internal air temperatures with elevation. The ambient temperature decreases linearly from 40.7 °C at the collector inlet to 28.2 °C at the chimney outlet. Within the collector, the internal air temperature increases and reaches its maximum near the chimney base. Beyond this point, the internal air temperature in the constant-excess formulation decreases at the ambient lapse rate, from 56 °C at the chimney base to 49 °C at the outlet. In contrast, the full formulation predicts a temperature decrease from 54 °C to approximately 44 °C over the same height. Figure 6b indicates that differences among the three formulations are already evident at the chimney base. The predicted excess temperatures are 21.3 K when adiabatic cooling is neglected, 21.6 K when it is included only in the chimney, and 19.6 K when the full formulation is applied. These differences are partly attributed to variations in the mass flow rates, which are 351, 346, and 333 t/s, respectively. and partly from the inclusion of adiabatic cooling within the inclined collector in the complete model. As shown in Figure 6c, the cumulative driving pressure remains nearly identical among the three formulations up to the chimney base, but the predictions diverge along the chimney. At this hour, the constant-excess formulation overpredicts the buoyancy-driven pressure difference by 108 Pa, with the discrepancy developing along the chimney. Including adiabatic cooling in the chimney alone reduces this overprediction by 31 Pa (29%), while accounting for adiabatic cooling in the collector removes the remaining 77 Pa (71%) by reducing the excess temperature entering the chimney from 21.6 to 19.6 K.
Figure 6. Effect of dry-adiabatic cooling on the highest-power hour with measured components (15 June 2022 10:00; GPOA = 1163 W m−2). (a) Air temperature. (b) Excess over ambient. (c) Cumulative driving pressure; the values at the chimney outlet are given, with the relative excess over the full formulation. The dotted line marks the chimney base, and the shaded zone is the collector on the slope. The no-adiabatic-term case is the constant-excess formulation (κc = κh = Γ). The ambient temperature falls at 6.5 K km−1 and is anchored at the outlet level (station temperature 28.2 °C), which gives 40.7 °C at the collector inlet (Section 3.3); λ = 0.8.
The effect of adiabatic cooling on annual energy production depends on turbine loading, as shown in Figure 7 and Table 5. The extent to which the constant-excess formulation overestimates energy production relative to the full formulation depends on the basis of comparison. At the same turbine loading, the overestimation is 33% at the reference value of λ = 0.8 (464 versus 350 GWh) and increases to 46% at λ = 0.5 (303 versus 207 GWh), before decreasing to 12% at λ = 0.99. When each formulation is evaluated at its own optimal loading, the difference is 21%, with the constant-excess model producing 502 GWh at λ = 0.92 compared with 416 GWh at λ = 0.96 for the full formulation. Comparisons at the same loading isolate the influence of the adiabatic term for a given turbine design, whereas comparing the optimized results also accounts for the shift in the optimal value of λ (Figure 7b). At λ = 0.8, including adiabatic cooling only in the chimney reduces the overestimation from 33% to 22%, corresponding to an annual energy production of 428 GWh. The remaining difference is associated with adiabatic cooling in the inclined collector. The simplified hybrid formulation, which assumes isothermal chimney air (κc = Γ, κh = 0), predicts 545 GWh at λ = 0.8 and 569 GWh at its optimum (λ = 0.90). These values are 56% and 37% higher than those of the full formulation, respectively. This hybrid case is retained in Table 5 for transparency only.
Figure 7. (a) Annual energy as a function of the turbine pressure fraction λ for the three thermodynamic formulations; stars mark the maxima and the arrow shows the overestimate at the reference value λ = 0.8. (b) Overestimate of the two reduced formulations relative to the full formulation for λ ≥ 0.5; open circles mark λ = 0.5 and 0.8. The overestimates of the constant-excess formulation are 46% at λ = 0.5 and 33% at λ = 0.8 (same-λ comparisons) and 21% for the ratio of the maxima (502/416 GWh), which occur at different λ.

5.3. Turbine Pressure Fraction

Annual energy generation increases nearly linearly with λ up to approximately 0.8, before reaching a broad maximum within the range of about 0.92–0.98 (Figure 7). The full model predicts a maximum annual energy output of 416 GWh at λ = 0.96, representing a 19% increase relative to the reference configuration. The optimal turbine pressure fraction is considerably higher than the approximately 2/3 value predicted for a simplified constant-buoyancy system. This difference arises because reducing the mass flow rate increases the collector temperature rise, thereby enhancing the buoyancy-driven pressure. However, at the optimal operating condition, the maximum collector temperature rise can reach 43 K and remains at least 33 K across the configurations presented in Table 13, compared with 20 K for the reference case. Under these conditions, the assumptions of constant heat-loss coefficients and constant turbine efficiency become less reliable. Therefore, the calculated optimum is considered an upper-bound estimate, while the reference pressure fraction is regarded as a more practical design operating point. The curves representing the formulation without adiabatic cooling and the formulation incorporating it only in the chimney (Figure 7) exhibit similar trends but reach their maximum energy output at lower turbine pressure fractions (λ = 0.92 and 0.94, respectively), compared with λ = 0.96 for the complete model. Consequently, neglecting adiabatic cooling also leads to a lower predicted optimal turbine loading. The relative overestimation of annual energy compared with the complete formulation is most pronounced at low values of λ (Table 5).
Table 13. Optimum constant turbine pressure fraction, annual energy and peak power for selected configurations.
The assumptions of constant turbine–generator efficiency and a fixed turbine pressure fraction were examined using two approaches. First, a part-load efficiency relationship, ηTG(q) = ηTG,0[1 − k(1 − q)2], with a minimum limit of 0.2 × ηTG,0, was applied to each hourly operating condition. Here, q represents the ratio of the actual mass flow rate to the rated value of 312 t s−1, corresponding to the 90th percentile of the mass flow at λ = 0.8. Two values of k were considered, 0.5 and 1.0, representing efficiency reductions of 12.5% and 25%, respectively, at half the rated flow. At λ = 0.8, the annual energy generation decreases from 349.6 GWh to 345.2 and 340.8 GWh, corresponding to reductions of 1.3% and 2.5%. In contrast, the maximum annual energy obtained by optimizing a constant λ decreases from 416 GWh at λ = 0.96 to 382 GWh at λ = 0.92 and 362 GWh at λ = 0.90, representing decreases of 8% and 13%, respectively. Second, the turbine pressure fraction was optimized independently for each hour within the range λ = 0.3–0.98 to maximize instantaneous power generation. This idealized control strategy produces annual energy outputs of 416.0, 381.6, and 361.9 GWh for k = 0, 0.5, and 1.0, respectively. These values exceed the corresponding optimal fixed-pressure-fraction results by no more than 0.1%, indicating that the assumption of a constant pressure fraction has little influence on the predicted annual energy under the examined conditions. Limiting the hourly optimization to λ ≤ 0.9, where the assumption of constant loss coefficients is more reasonable, results in annual energy outputs of 398, 380, and 362 GWh, respectively. These findings indicate that turbine off-design operation reduces the reference annual energy by up to 2.5%, while its influence on the optimized configurations is more pronounced. This supports the selection of λ = 0.8 as a practical design operating point and the interpretation of the optimum reported in Table 5 as an upper-bound estimate. It should be emphasized that the adopted part-load efficiency relationship is an assumed representation rather than a characteristic derived from an actual turbine design.

5.4. Equivalent Chimney Height of the Slope

Table 14 and Figure 8a present the annual energy generation of plants installed on slopes ranging from 0° (horizontal terrain) to 20°, with chimney heights between 0 and 1000 m. For flat-ground configurations, annual energy increases by approximately 57–60 GWh for each additional 250 m of chimney height in the lower half of the height range, while the increase is about 51 GWh over the final 250 m. This trend indicates a gradual saturation effect associated with the inclusion of adiabatic cooling. Even without a vertical chimney, an inclined plant with β = 12.95° produces 154 GWh annually, equivalent to the output of a flat-ground configuration with a chimney height of approximately 665 m (Figure 8b). The corresponding equivalent chimney heights are 248, 504, 665, 780, and 1080 m for collector inclination angles of β = 5°, 10°, 12.95°, 15°, and 20°, respectively, with the final value obtained by extrapolation. These heights represent 0.71, 0.72, 0.72, 0.73, and 0.74 of the corresponding terrain elevation gains. Under optimal turbine loading, the equivalent-height ratios increase to 0.74 at β = 10°, 0.75 at β = 12.95°, and 0.79 at β = 20°, with the latter based on extrapolation. Across the investigated inclination angles and loading conditions, the ratio ranges from 0.71 to 0.79 for plants without a chimney (Hc = 0); with the 1000 m chimney of the reference plant, the ratio rises to 0.84 (Section 4.3). Thus, for chimney-free configurations, each meter of terrain elevation gain provides an energy benefit approximately equivalent to three-quarters of a meter of conventional chimney height. The difference is attributed to the lower average air temperature along the inclined collector compared with the chimney. As illustrated in Figure 8a, the energy-generation curves for different inclination angles are not parallel. At β = 20°, the inclined collector contributes an additional 241 GWh in the absence of a chimney, but only 189 GWh when combined with a 1000 m chimney. This reduction in the incremental benefit occurs because both the collector inclination and chimney height contribute to the vertical extent of the buoyant airflow, resulting in diminishing additional energy gains as the total elevation increases. Figure 8b further indicates that the equivalent-height values follow an approximately linear relationship below the identity line. The additional energy gained from the slope decreases as chimney height increases, falling from 154 GWh without a chimney to 125 GWh with a 1000 m chimney at a slope angle of 12.95°. However, because the flat-ground energy curve approaches saturation more rapidly, the corresponding equivalent-height ratio increases from 0.72 to 0.84 (Section 4.3).
Table 14. Annual energy (GWh) at λ = 0.8 as a function of slope inclination and chimney height. Hs is the terrain rise; Heq is the equivalent chimney height of the slope alone (extrapolated beyond 1000 m, marked *).
Figure 8. (a) Annual energy versus chimney height for several slope inclinations (λ = 0.8). (b) Equivalent chimney height of the slope versus terrain rise; the dotted line would apply if each meter of rise were worth a meter of tower.
Inclined collectors also enhance the annual energy generation of plants with tall chimneys. For a 1000 m chimney, a collector inclination of 12.95° increases annual energy from 224 to 350 GWh (+56%) at λ = 0.8, and from 246 to 416 GWh (+69%) under optimal turbine loading. The relative improvement is greater for shorter chimneys. For instance, a 500 m chimney produces 117 GWh annually on flat terrain, compared with 262 GWh when installed with a collector inclined at 12.95°. This configuration is particularly relevant where constructing very tall chimneys is impractical (Table 13).

5.5. Ambient Lapse Rate

The annual energy output is strongly influenced by the ambient atmospheric lapse rate (Figure 9a). At λ = 0.8, the predicted annual energy generation is 294, 350, and 460 GWh for Γ = 4.5, 6.5, and 9.76 K km−1, respectively, corresponding to changes of −16% and +31% relative to the standard-atmosphere case. Under dry-adiabatic ambient conditions (neutral stratification), the excess temperature remains constant with elevation. Applying the hourly lapse rate derived from the two monitoring stations (annual mean of 5.3 K km−1 and approximately 4 K km−1 at midday) results in 291 GWh (−17%). However, this surface-based estimate does not adequately represent the vertical atmospheric conditions experienced by the plant.
Figure 9. (a) Annual energy versus ambient lapse rate (λ = 0.8); the green diamond is the hourly ERA5 lapse rate of the 850–650 hPa layer (below-ground cells excluded) and the open square is the two-station surface value. (b) ERA5 lapse rate by month (mean over 0.25° cells around Abha, September 2021–August 2022) for two layers, with the 5–95th percentile band for 850–650 hPa. The two-station and hourly ERA5 points are driven by hourly lapse rates, so they do not lie on the constant-Γ curve; the surface value falls to about 4 K km−1 at midday, when most of the energy is produced.
To obtain a more representative estimate of Γ, ERA5 reanalysis data [77,78] were examined. The dataset includes hourly temperature and geopotential values at 14 pressure levels over a 7 × 7 grid with a spatial resolution of 0.25° surrounding Abha throughout the analysis year. Lapse rates were computed for each grid cell and averaged over the cells in which both levels of the layer lie above the ground (Section 3.3). For the 850–650 hPa pressure layer, corresponding to mean elevations of approximately 1.5–3.8 km and covering the plant’s operating height range, the mean lapse rate is 6.5 K km−1, with a 5–95th percentile range of 4.4–8.3 K km−1. This value is close to the standard-atmosphere lapse rate of 6.5 K km−1. The lowest lapse rates occur during December–February (4.9–5.4 K km−1), while the highest values are observed in April–June (7.6–7.7 K km−1; Figure 9b). For the 750–600 hPa layer, spanning approximately 2.6–4.4 km, the mean lapse rate increases to 7.3 K km−1. Using the hourly lapse rates from the 850–650 hPa layer in the model produces an annual energy output of 352 GWh, approximately 0.6% higher than the standard-atmosphere prediction. A constant lapse rate of 6.8 K km−1 gives 359 GWh, whereas the hourly values from the 750–600 hPa layer yield 376 GWh. Since the 850 and 800 hPa pressure levels are below the station elevation (Section 3.3), the calculation was repeated using the 750–650 hPa layer (2580–3777 m), which lies entirely above the station. This gives a mean lapse rate of 7.3 K km−1 and an annual energy production of 376 GWh (+7.6%) when the hourly lapse-rate values are used. The annual energy predicted using the hourly 850–650 hPa lapse rates is slightly higher than that obtained from the constant-Γ relationship in Figure 9a (352 versus 350 GWh for a constant Γ equal to the same mean of 6.5 K km−1). This difference is consistent with the higher lapse rates observed during April–June, when the plant also generates relatively high power (Figure 4a and Figure 9b). Therefore, the standard-atmosphere assumption provides a representative reference for the elevation range of the proposed plant, whereas the surface-derived lapse rate of 5.3 K km−1 appears to underestimate the atmospheric lapse rate relevant to the system. Previous reference plant models have commonly assumed dry-adiabatic daytime atmospheric conditions [21]. However, the hourly ERA5 data indicate a mean lapse rate of 6.5 K km−1 during the 4778 evaluated daylight records, with a 5–95th percentile range of 4.4–8.2 K km−1. A lapse rate of 9 K km−1 is reached during only 0.25% of these hours. Consequently, the assumption of a neutrally stratified atmosphere, which predicts 460 GWh annually (Figure 9a), is not supported by the reanalysis data for this location. Nevertheless, the 0.25° spatial resolution of ERA5 may smooth atmospheric variations in the lower layers. Mean annual air temperatures reported for vegetation zones in the Asir region at average elevations of 1397 m (26 °C) and 2140 m (22 °C) suggest a temperature gradient of approximately 5 K km−1 [79]. However, this represents an indirect near-surface indication rather than a measurement of the free-atmosphere lapse rate.
Two limitations should be considered. First, the relatively coarse spatial resolution of ERA5 (0.25°) may not fully capture local atmospheric variations. In addition, the 850 and 800 hPa pressure levels lie below the station elevation, meaning that the lower part of the 850–650 hPa layer includes grid cells where these levels fall below the local ground surface. Such cells were identified using ERA5 surface pressure data for each grid cell and excluded before spatial averaging (Section 3.3). Without this exclusion, the mean lapse rate would increase to 6.7 K km−1, resulting in an annual energy production of 365 GWh, approximately 3.6% higher than the estimate obtained with the exclusion (352 GWh). The 750–650 and 750–600 hPa layers, which lie entirely above the station elevation and are unaffected by this issue, produce annual energy estimates 7–8% higher than the reference value. Despite this limitation, the estimated lapse rate of approximately 6.5–7.3 K km−1 across the plant’s elevation range remains relatively consistent when different pressure layers are considered.
Second, the method used to determine the inlet atmospheric conditions from station temperature and Γ (Section 3.3) was assessed against ERA5. The predicted temperature at 850 hPa shows a mean bias of +0.3 K relative to the reanalysis data, but exhibits diurnal differences of +4.2 K at noon and −3.3 K at 06:00 local time. These variations are associated with the influence of surface heating on the station measurements. When the inlet temperature is obtained directly from ERA5, the predicted annual energy increases to 356 GWh, approximately 2% above the reference result. This suggests that the station-based inlet-temperature assumption provides a slightly conservative estimate. No radiosonde temperature profiles were included in the analysis.
The approach described in Section 3.3 assumes that the meteorological station is located at the elevation of the reference plant’s chimney outlet. This assumed position is higher than the actual station elevation relative to a chimney installed at the mountain crest, where the chimney base would coincide with the station level. Two alternative station elevations were examined for the reference configuration (β = 12.95°, Hc = 1000 m, λ = 0.8): one placing the station at the chimney base, 917 m above the collector inlet, and the other at the collector inlet itself. Table 3 lists the resulting absolute elevations. The predicted annual energy generation is 349.6 GWh under the convention adopted in Section 3.3, increasing to 359.2 GWh (+2.7%) when the station is positioned at the chimney base and 367.9 GWh (+5.2%) when it is located at the collector inlet. These results indicate that the original convention produces a conservative annual energy estimate by up to approximately 5%. When the station elevation is assigned to the chimney base for each configuration, allowing the inlet atmospheric conditions to vary with collector inclination, the corresponding equivalent chimney heights are 251, 506, 665, 776, and 1062 m for β = 5°, 10°, 12.95°, 15°, and 20°, respectively. These values correspond to 0.72–0.73 of the terrain elevation gain, compared with 0.71–0.74 when a common inlet state is applied. Thus, the equivalent-height ratio shows little sensitivity to the selected atmospheric reference elevation.

5.6. Collector Parameters, Orientation, Terrain Geometry and Hydraulics

Annual energy generation is highly sensitive to optical efficiency and moderately affected by the collector roof heat-loss coefficient (Figure 10a). At λ = 0.8, varying ηopt from 0.30 to 0.40 produces annual energy outputs ranging from 287 to 413 GWh at Ucol = 5 W m−2 K−1. Similarly, varying Ucol between 3 and 7 W m−2 K−1 results in annual energy generation of 325–376 GWh at ηopt = 0.35. The orientation of the collector sector also influences energy generation by changing the incident solar irradiation (Figure 10b). An east-facing sector produces 335 GWh (−4%), while a west-facing sector generates 323 GWh (−8%) compared with the south-facing configuration. For a potential site with a west-facing escarpment, as may occur along terrain descending toward the Red Sea, the south-facing predictions would overestimate annual energy generation by approximately 8%. The ratio of solar irradiation incident on the inclined roof to GHI is 1.030 for a south-facing collector at β = 12.95°, compared with 0.995 for an east-facing orientation and 0.965 for a west-facing orientation. Consequently, the relative reductions in energy generation (−4% and −8%) are approximately 1.25 times the corresponding reductions in incident irradiation. This behavior is consistent with the system’s sensitivity to solar irradiation discussed in Section 7. At the latitude of the study site, the irradiation benefit associated with collector inclination is relatively small compared with the greater advantage reported by Li et al. [30] for a 25° slope at 35° N.
Figure 10. (a) Annual energy (GWh) for combinations of optical efficiency and roof loss coefficient (λ = 0.8); the black frame marks the reference case. (b) Effect of sector orientation, with the change relative to the south-facing sector in brackets.
The Copernicus GLO-30 digital elevation model (30 m resolution) [69] was employed to replace the idealized conical terrain with actual topographic data. The station elevation obtained from the model (2165 m) is consistent with the altitude estimated from atmospheric pressure. Potential collector sectors with the dimensions specified in Table 6 (120° opening angle, inner radius of 500 m, and outer radius of 4490 m) were assessed for chimney locations distributed on a 600 m grid within a 30 km radius of Abha, considering orientations from 180° to 300° at 15° intervals. For each candidate sector, terrain elevations were averaged across the sector azimuths to construct a radial elevation profile, while the local terrain slope was calculated at a spatial scale of 150 m. Sectors were retained when their radial profiles showed a decrease in elevation over at least 90% of the steps and the chimney location corresponded to the highest terrain elevation within the sector. From the qualifying candidates, six sectors were selected. Sectors S1–S5 were identified by choosing the sector with the lowest average local slope within each 200 m elevation-gain interval between 300 and 1300 m. Sector S6 was selected based on the maximum terrain elevation gain (Figure 11). Figure 11a illustrates the geographic locations of the selected sectors. Sectors S1–S5 are situated along the escarpment southeast of the monitoring station, whereas S6 lies to the west. The sector-averaged elevation profiles presented in Figure 11b indicate that S1–S3 remain nearly horizontal over the first kilometer before becoming steeper toward the outer rim. Sector S4 includes a relatively level section near 800 m along the radial distance between 1 and 2.5 km, while S5 and S6 exhibit a more continuous decline in elevation away from the chimney. The uniform collector inclinations of 9.3° and 12.95° considered in the preceding sections, corresponding to elevation gains of 657 and 917 m, respectively, represent an elevation gain between those of S2 and S3 and one comparable to S4, respectively.
Figure 11. Copernicus GLO-30 terrain around Abha with the collector sectors S1–S6 of Table 4 (a), and the sector-mean ground profile of each sector compared with uniform slopes of 9.3° and 12.95° (b). Contains Copernicus DEM GLO-30 data (© DLR e.V. 2010–2014 and © Airbus Defence and Space GmbH 2014–2018, provided under COPERNICUS by the European Union and ESA; all rights reserved).
The model was applied to each selected sector using its sector-averaged elevation profile to represent the collector surface, its orientation to define the sector center for solar irradiance calculations, and the inlet atmospheric conditions determined from the station data at the elevation of the outer rim (Table 4). Absolute elevations of the rim, chimney base and chimney outlet of each sector are given in Table 3. For a 1000 m chimney operating at λ = 0.8, annual energy generation increases from 257 GWh for S1, with a terrain elevation gain of 302 m, to 403 GWh for S6, with a rise of 1235 m. With a 500 m chimney, the corresponding energy output increases from 155 to 321 GWh. The results indicate that annual energy generation is primarily influenced by the terrain elevation gain. Relative to a uniform slope with an equivalent vertical rise, the sector-averaged terrain profile produces energy differences ranging from −7% to +2%, including −4% for S1, −6% for S3, −7% for S4, and +2% for S6. These findings suggest that the shape of the terrain profile has a smaller influence on energy generation than the total elevation gain. The uniform 12.95° configuration examined in the preceding sections (350 GWh) is reproduced within 1% by a uniform slope having the same elevation gain as S4 (906 m), which produces 351 GWh annually.
The primary limitation is the ruggedness of the terrain. Sectors with substantial elevation gains are located along the highly dissected escarpment, where S4 has an average local slope of 20°, with 32% of its footprint exceeding a slope of 30°. For S6, the corresponding values are 28° and 41%. Installing a ground-following collector roof in these areas would be impractical, while a roof spanning the deep ravines would require supporting structures considerably more extensive than those considered in the present model. The sectors characterized by relatively moderate terrain slopes have smaller elevation gains (S1: 8.7° and S2: 14.5°), producing annual energy outputs of 257 and 289 GWh, respectively, with a 1000 m chimney. Therefore, the reference prediction of 350 GWh at β = 12.95° should be considered an upper estimate for a solar collector situated along the Asir escarpment. For preliminary screening, this study adopts an author-defined criterion, rather than an established engineering standard, under which a sector is classified as moderate if its mean local slope is below 15° and no more than approximately 25% of its footprint has slopes exceeding 30°. Only S1 (8.7°, 12%) and S2 (14.5°, 21%) meet these conditions, while S3–S6 have mean slopes ranging from 18.5° to 27.9°, with 27–41% of their areas exceeding a 30° slope. Accordingly, the estimated annual energy production of 260–290 GWh for S1 and S2 remains conditional on the sector-averaged ground profiles and should not be interpreted as evidence of a buildable configuration. Local ravines, foundation requirements, roof support structures, and site accessibility have not been resolved, and assessing the feasibility of a 21.4 km2 ground-following collector roof (120° sector, 500–4490 m radius) is beyond the scope of this study. S1 and S2 are located 27 and 26 km from the meteorological station, respectively, with their inlets 214 and 464 m below the station elevation. Applying the Abha weather records to these locations does not capture potential local differences in cloud cover or ambient temperature, and the sensitivity of the predictions to this transfer has not been quantified.
Within-sector terrain variability and horizon shading are assessed quantitatively in Table 15. The standard deviation of DEM elevations relative to the sector-mean radial profile is 135 m for S1 and 228 m for S2. The actual terrain also differs from the averaged profile by more than 40 m across 50% and 75% of the respective collector footprints. Consequently, a ground-following collector roof would require substantial earthworks or structural spans across depressions, and the sector-averaged profile should be regarded as an idealized representation of the collector surface. Horizon shading was estimated at five reference points within each sector, including three along the central axis and two positioned at ±40° from it, using DEM-derived horizon profiles within a 15 km radius. The resulting shading blocks 0.1% of the annual beam irradiation on a horizontal plane in S1 and 4.2% in S2. This reduces the predicted annual energy production by 0.04% in S1 (from 257.4 to 257.3 GWh) and 2.2% in S2 (from 289.2 to 283.0 GWh). Across all six sectors (S1–S6), the reduction ranges from 0.04% to 2.8%. After accounting for horizon shading, the estimated annual energy production for S1 and S2 ranges from approximately 257 to 283 GWh. However, because the 30 m DEM cannot fully resolve local ravine walls, these estimates represent lower bounds on the potential shading losses.
Table 15. Within-sector terrain variability and horizon shading of the sectors of Table 4 (Hc = 1000 m, λ = 0.8). σz is the standard deviation of the DEM elevation about the sector-mean radial profile; the beam loss is the fraction of annual beam irradiation on a horizontal plane blocked by the DEM horizon, averaged over five reference points per sector.
For comparison, uniform collector inclinations of 3°, 5°, 7°, 9.3°, and 12.95°, using the original atmospheric reference convention (station elevation corresponding to the chimney outlet), produce annual energy outputs of 255, 275, 294, 316, and 350 GWh, respectively, for a chimney height of 1000 m.
The idealized conical-slope representation also overestimates the elevation gain of a planar collector sector. Applying a reduction factor of 0.827, corresponding to the mean cosine over an angular range of ±60°, decreases the terrain rise to 759 m and reduces the predicted annual energy generation from 349.6 to 333.5 GWh (−4.6%).
Hydraulic parameters have a relatively limited influence on energy generation, and their behavior differs from what would be expected in a system dominated by pressure losses (Figure 12a). At λ = 0.8 and Kturn = 1, annual energy decreases from 354 GWh with a collector gap of 15 m to 309 GWh when the gap increases to 50 m. This occurs because a larger gap increases the mass flow rate, reducing the collector temperature rise and consequently the buoyancy-driven pressure. In comparison, hydraulic losses account for only 20% of the driving pressure during the peak-power hour. The influence of Kturn is small, with annual energy increasing slightly as Kturn increases because the restricted airflow produces a higher collector temperature.
Figure 12. Annual energy versus collector gap for three turning-loss coefficients. (a) λ = 0.8. (b) λ = 0.5. The vertical axes do not start at zero.
A similar trend is observed at λ = 0.5 (Figure 12b), where annual energy for Kturn = 1 decreases from 215 to 167 GWh as the collector gap increases from 15 to 50 m. The corresponding maximum throat velocity is 19 m s−1 for a 15 m gap and 11 m s−1 for a 50 m gap. Therefore, the minimum practical collector gap is primarily constrained by airflow velocity and structural requirements of the roof rather than by energy generation alone.

5.7. Ground Thermal Storage

The quasi-steady model does not account for thermal energy storage; therefore, power generation is limited to daylight hours. A preliminary assessment considers a linear thermal reservoir within the ground, where a fraction f of the absorbed solar energy is stored and subsequently transferred to the airflow with a time constant τ. Under this assumption, the total absorbed energy remains unchanged, while its temporal distribution is modified. The heat release is assumed to be independent of air temperature, which favors electricity generation during nighttime. For f = 0.2 and τ = 3 h, the predicted annual energy generation at λ = 0.8 decreases from 349.6 to 329 GWh. Increasing τ to 6 h reduces the annual output to 316 GWh. When the storage fraction increases to f = 0.4, the corresponding annual energy outputs are 317 GWh for τ = 3 h and 296 GWh for τ = 6 h. Nighttime electricity generation ranges from 1 to 15 GWh, accounting for no more than 5% of the annual total. Meanwhile, the maximum power output decreases from 214 MW to a range of 148–189 MW. This behavior occurs because the power output increases more than proportionally with the thermal energy supplied to the airflow. Consequently, distributing the same amount of heat over a longer period reduces the total energy generated. Thus, thermal storage produces a smoother power-generation profile but decreases rather than increases annual energy output under the assumptions of the present model. The storage fractions and time constants considered in this analysis are assumed rather than experimentally determined. They are intended to cover a plausible range of operating conditions and require calibration against measurements from an actual solar chimney plant.

5.8. Global Sensitivity Analysis

Table 7 and Figure 13 present the results of the Latin hypercube sensitivity analysis. Across the sampled parameter ranges, the annual energy generation has a mean of 309 GWh and a standard deviation of 91 GWh, with 5th, 50th, and 95th percentile values of 178, 297, and 480 GWh, respectively. The rank regression model accounts for 95% of the variance. The most influential parameters are the turbine pressure fraction (SRRC = 0.66), optical efficiency (0.48), atmospheric lapse rate (0.43), and turbine–generator efficiency (0.26). The collector roof heat-loss coefficient exhibits a weaker negative influence (−0.19), whereas the chimney heat-loss coefficient, friction factors, Kturn, Kexit, and collector gap all have absolute SRRC values below 0.04. The annual energy distribution shown in Figure 13b is positively skewed, with a mean of 309 GWh and a median of 297 GWh, and extends from 92 to 552 GWh, representing approximately a sixfold difference between the minimum and maximum values. Consequently, the predicted annual energy varies by more than a factor of two across the considered input ranges, with a 5–95th percentile interval of 178–480 GWh. In contrast, the equivalent-height ratio discussed in Section 5.4 remains relatively consistent across the investigated collector slopes and turbine loading conditions. It should be noted that the turbine pressure fraction λ represents a design parameter rather than an uncertain input. Therefore, its contribution to the overall variation should be interpreted separately.
Figure 13. Global sensitivity analysis. (a) Standardized rank regression coefficients. (b) Distribution of annual energy over the 360 samples; lines mark the 5th, 50th and 95th percentiles.
To investigate this distinction, the original 360 samples were initially narrowed to 80 cases with λ between 0.75 and 0.85. This subset produced a 5–95th percentile range of 243–488 GWh, with R2 = 0.90. However, because this restricted sample did not fully isolate the individual effects, an additional Latin hypercube analysis was conducted at a fixed λ = 0.8. The remaining ten parameters were sampled independently from the ranges given in Table 7, assuming uniform distributions without imposed correlations. A total of 720 cases were evaluated, each using every eighth operating hour. Compared with the full hourly series, this temporal sampling introduced an average difference of 0.5% and a maximum difference of 1.1%, while preserving the same ranking of parameters. The resulting annual energy production has a mean of 346 GWh and a standard deviation of 75 GWh, with the 5th, 50th, and 95th percentiles at 229, 345, and 468 GWh, respectively. The standardized rank regression gives an R2 of 0.95. The corresponding coefficients, reported in the final column of Table 7, identify optical efficiency (0.69), lapse rate (0.54), turbine–generator efficiency (0.35), and roof heat-loss coefficient (−0.28) as the most influential parameters. All remaining coefficients have absolute values below 0.05. The bootstrap 95% intervals for the four leading coefficients are 0.65–0.72, 0.51–0.57, 0.33–0.38, and −0.31 to −0.26, respectively. The corresponding intervals for the estimated 5th and 95th percentiles are 222–238 and 461–478 GWh. The results also show good convergence with increasing sample size. For N = 90, 180, 360, and 720, the 5–95th percentile ranges are 229–465, 226–465, 238–466, and 229–468 GWh, respectively. The standardized rank regression coefficient for optical efficiency remains nearly constant at 0.67, 0.69, 0.68, and 0.69, while the four most influential parameters retain the same ranking across all sample sizes. These results represent parameter-conditioned scenario ranges obtained by uniformly sampling the intervals specified in Table 7, with equal weighting across the sampled parameter values. They should not be interpreted as probabilistic confidence intervals for the energy output of an actual plant. The parameter ranges were selected by the author rather than derived from measured probability distributions, the uniform sampling was imposed by design, and structural uncertainties discussed in Section 4.3 and Section 7 were not included.

5.9. Summary of the Estimate and Its Range

Table 16 summarizes the annual energy generation of the reference plant under the different assumptions evaluated in this section and Section 4.3. Each row represents a change in a single assumption compared with the reference configuration (λ = 0.8, 349.6 GWh). These changes are not cumulative, and the results should not be interpreted as a probability distribution. A conditional annual energy estimate of approximately 260–290 GWh is obtained for the two moderate-slope sectors, S1 and S2 (Section 5.6), decreasing to 257–283 GWh when horizon shading is considered. These estimates depend on the sector-averaged terrain profiles and do not establish the feasibility of constructing the proposed system. In contrast, the 350 GWh predicted for the idealized conical geometry represents the upper-bound estimate.
Table 16. Annual energy of the reference plant (λ = 0.8) when one assumption is changed at a time.

6. Discussion

The main quantitative finding of the one-dimensional model is that natural terrain inclination can replace part of the structural chimney height. For chimney-free configurations, each meter of terrain elevation gain is equivalent to approximately 0.71–0.79 m of flat-ground chimney height across the investigated slopes and turbine loading conditions. This ratio increases to 0.84 for the reference configuration with a 1000 m vertical chimney. The use of inclined terrain has previously been proposed [26] and examined for particular locations and configurations [22,23,24,25,27,28,31,32,34,35,36,37,38,39,40,42,43,44,45,46,47]. A CFD investigation of a 35° slope reported that the required chimney height for a specified system volume decreased by approximately 36% [42], although this represents a different type of equivalence. Zhou et al. [23] reported that an inclined-collector plant with a collector elevation gain of 848 m and a vertical chimney height of 123 m produced pressure potential and power output between those of conventional horizontal-collector plants with chimney heights of 547 m and 971 m. These values correspond to 0.56–1.0 of the total vertical height of 971 m, a range that includes the equivalent-height ratios of 0.71–0.79 obtained in the present study. Among the reviewed literature, we did not identify a study that quantified the slope benefit through a single equivalent chimney height under stable atmospheric conditions using full-year hourly simulations. For a terrain elevation gain of 917 m, the equivalent chimney height ranges from 665 m at λ = 0.8 to 692 m under optimal turbine loading. Accordingly, an inclined plant incorporating a 250 m chimney (211 GWh) generates approximately the same annual energy as a flat-ground configuration with a 933 m chimney. Similarly, an inclined system with a 500 m chimney (262 GWh) produces more energy than a conventional flat-ground plant with a 1000 m chimney (224 GWh), assuming the idealized terrain geometry is applicable (Table 14). The equivalent-height ratio remains below unity due to the underlying thermodynamic behavior. As the heated air moves upward along the inclined collector, its temperature increases gradually, resulting in a lower average excess temperature along the slope compared with that within the vertical chimney.
Under stable atmospheric conditions, the temperature excess of the rising airflow decreases with elevation, resulting in diminishing benefits from increasing chimney height. The constant-excess formulation assumes that the internal air cools at the same rate as the ambient air, preventing the excess temperature from decreasing with elevation. This assumption leads to an overestimation of annual energy production by 33% at λ = 0.8, increasing to 46% at λ = 0.5 and decreasing to 21% when each formulation is optimized independently. The magnitude of this discrepancy is comparable to the combined variation resulting from changes in optical efficiency and the collector roof heat-loss coefficient within the investigated ranges (approximately −24% to +27%). Therefore, models that neglect adiabatic cooling, including simplified constant-temperature-excess approaches [13,15], should be applied cautiously to tall or inclined solar chimney plants. This finding is fundamentally different from the 0.9% variation reported by Pretorius and Kröger [21]. Their investigation modified the ambient atmospheric conditions while retaining adiabatic cooling within the plant. In contrast, the present comparison removes the cooling effect experienced by the rising airflow itself. Consequently, the two findings are not contradictory. Detailed formulations that account for adiabatic cooling [8,9,10,11,12] therefore provide a more appropriate basis for comparison. Similarly, Koonsrisuk [32] reported that assuming identical density differences between the collector and chimney produces substantial overprediction, which is consistent with the direction of the overestimation observed in the present study. Using a compressible-flow model, Zhou et al. [23] also demonstrated that both gravitational effects and atmospheric density variations with elevation must be considered when calculating the driving force in inclined solar chimney collectors.
Annual energy generation increases by 19% under optimal turbine loading compared with λ = 0.8, while the variance analysis identifies λ as the most influential parameter. In practice, a plant would operate with a variable turbine pressure fraction; therefore, its actual power output depends on the turbine design and control strategy, which are not explicitly considered in the present study. Accordingly, we recommend presenting the predicted results as conditional ranges and quantifying the advantage of terrain inclination using relative measures, such as the equivalent chimney height.
The overall system efficiency of 0.73% is comparable in magnitude to the efficiencies of approximately 1% or less reported for large-scale SCPP designs [6,8]. Bilgen and Rheault [26] reported an overall thermal performance slightly below 0.5% for inclined plants at Canadian locations, achieving up to 85% of the power output of comparable plants in southern regions equipped with horizontal collectors. For illustrative purposes, a photovoltaic system with a module efficiency of 20%, a performance ratio of 0.8, and a ground coverage ratio of 0.4, installed over the same 21.4 km2 area, would produce approximately 3.0 TWh of electricity annually under the measured solar irradiation conditions. This is nearly nine times the annual energy generation of the reference solar chimney plant. Therefore, the feasibility of an SCPP would need to be supported by additional advantages not represented in the present model, including thermal energy storage, extended service life, or specific site constraints. A detailed techno-economic comparison is beyond the scope of this study.
Under the assumptions of the present study, (i) the collector should be oriented to maximize incident solar irradiation, and the terrain axis should be selected accordingly; a west-facing escarpment reduces annual energy generation by approximately 8%; (ii) a smaller collector gap is preferable from an energy-generation perspective, although peak throat velocities of 17 m s−1 at a 20 m gap and 19 m s−1 at a 15 m gap suggest that structural and aerodynamic limitations will determine the minimum practical gap; and (iii) chimney diameter and height should be optimized together with the turbine design, given the relatively high optimal turbine pressure fraction.

7. Limitations

The findings of this study depend on several assumptions and should be interpreted within these limitations. The collector surface is represented by the azimuthally averaged terrain elevation within each sector rather than the actual three-dimensional topography. Consequently, the model does not account for ravines, local terrain slopes ranging from 20° to 50° along the escarpment, site accessibility, or foundation requirements. The standard deviation of DEM elevations relative to the averaged terrain profile ranges from 126 to 255 m (Table 15), while the influence of horizon shading is only bounded in Section 5.6. In addition, meteorological data from the Abha station are applied to locations 26–33 km away. The model employs a quasi-steady formulation without explicit ground thermal storage. A preliminary linear-reservoir analysis (Section 5.7), based on assumed parameters, predicts nighttime electricity generation of no more than 5% of the annual total, along with reduced annual energy output. However, this simplified approach does not represent a calibrated ground thermal model. The heat-loss and efficiency parameters (ηopt, Ucol, Uch, ηTG, friction factors, and local loss coefficients) are assumed constant. In actual operation, roof heat losses vary with temperature and wind conditions, while turbine efficiency depends on the operating point. These constant-parameter assumptions become particularly uncertain near the optimal turbine loading. Specifically, ηopt = 0.35 is an assumed effective optical efficiency for a collector roof of the proposed scale, whereas the Manzanares comparison (Section 4.2) requires values of 0.5–0.6 combined with a higher roof heat-loss coefficient. Therefore, the predicted annual energy production should be considered within the parameter-conditioned scenario ranges reported in Table 7 (178–480 GWh, or 229–468 GWh at a fixed λ = 0.8), rather than being treated as a single definitive value.
The effects of wind and humidity are not explicitly considered. The Abha meteorological dataset does not include wind measurements, and moist-air properties are neglected. Zhou et al. [24] reported that humidity affects the pressure potential and power output of inclined-collector solar chimney plants. As an approximate representation of wind-enhanced roof heat losses, increasing Ucol from 5 to 6.5, 8, and 10 W m−2 K−1 reduces annual energy generation at λ = 0.8 from 349.6 to 330.7, 312.7, and 289.9 GWh, corresponding to reductions of 5.4%, 10.6%, and 17.1%, respectively. The maximum power output also decreases from 214 (full series) to 205, 196, and 185 MW. These results indicate that wind-induced roof heat losses could reduce the predicted performance, and the reference value of 5 W m−2 K−1 should be regarded as a favorable assumption. The ambient atmospheric lapse rate is prescribed as Γ = 6.5 K km−1. The ERA5 analysis (Section 5.5) gives a similar mean value after excluding pressure-level data located below the local ground surface in each grid cell. However, the relatively coarse spatial resolution of ERA5 (0.25°) and the absence of radiosonde measurements remain sources of uncertainty. Therefore, Γ remains an important source of environmental uncertainty in the model.
The meteorological inputs are based on one complete year of measurements, while the additional months in the 20-month record are used only for the consistency check presented in Section 4.4. The analysis year received 3.6% less global horizontal irradiation (GHI) than the long-term atlas value (Section 2.4), corresponding to a difference of approximately 4.6% in annual energy production. This highlights interannual variability in energy yield as a significant limitation that has not yet been quantified, indicating the need for simulations covering multiple years. Varying the hourly solar irradiation of the analysis year by ±5% changes the predicted annual energy at λ = 0.8 by approximately ±6%, giving 372 and 328 GWh. Thus, a difference of a few percent between the selected year’s irradiation and the long-term average can produce an energy variation approximately 1.25 times as large. The comparison with long-term irradiation averages is presented in Section 2.4. Experimental measurements for large-scale inclined solar chimney plants are not available in the reviewed literature. Furthermore, data from existing small-scale prototypes [45,46,47] could not be accessed, preventing direct experimental validation of the inclined configuration. The Manzanares comparison therefore serves only as a plausibility assessment. The discrepancy between the present model and the published CFD study of a small-scale inclined plant [29] remains unresolved, with equivalent-height ratios of 0.91–1.06 and 0.32–0.65, respectively (Section 4.3). Consequently, the equivalent chimney heights predicted in this study may be overestimated. The structural feasibility of a chimney measuring 1000 m in height and 300 m in diameter, together with construction costs, environmental restrictions, and land-use considerations, is beyond the scope of this investigation. In the absence of a practical demonstration at such a scale, configurations with chimney heights of 500 m or less may be more relevant for future development. Wind effects are accounted for only through the roof-loss proxy described above. However, external winds may also increase the kinetic power of the airflow exiting an inclined chimney [31].

8. Conclusions

A one-dimensional thermo-hydraulic model was developed to assess the performance of an inclined solar chimney power plant using measured hourly meteorological data from Abha, Saudi Arabia. The model incorporates dry-adiabatic cooling in both the collector and chimney, allowing for the influence of terrain elevation on buoyancy-driven power generation to be evaluated. The results show that terrain elevation can partially substitute for structural chimney height, with an equivalent-height ratio of 0.71–0.79 for chimney-free configurations across the investigated slopes and turbine loading conditions. This ratio increases to 0.84 for the reference configuration with a 1000 m vertical chimney. Collector inclination increases annual energy production by 56–69% for a plant with a 1000 m chimney. For the reference configuration with a 12.95° slope and a turbine pressure fraction of λ = 0.8, the predicted annual energy production is approximately 350 GWh. Neglecting adiabatic cooling overestimates annual energy by 33% at the reference loading (λ = 0.8), by 46% at λ = 0.5, and by 21% when the models are optimized separately, demonstrating the importance of including this effect in tall and inclined solar chimney models. However, the predicted equivalent-height ratios exceed the 0.32–0.65 range inferred from a published CFD study, and this discrepancy remains unresolved. The idealized 350 GWh prediction should therefore be treated as an optimistic estimate rather than a validated performance value. Using sector-averaged digital elevation model (DEM) profiles, annual energy production ranges from 257 to 403 GWh. For the two moderate-slope sectors, the estimated output is 260–290 GWh, decreasing to 257–283 GWh when horizon shading is considered. These estimates remain conditional and do not establish construction feasibility. Sensitivity analysis identifies turbine loading, optical efficiency, and atmospheric lapse rate as important factors affecting annual energy production. The study is further limited by its reliance on a single year of meteorological data, simplified heat-loss and turbine performance models, unresolved terrain characteristics, and the lack of experimental validation of the inclined configuration. Future work should focus on three-dimensional CFD and experimental investigations, improved component performance models, and multi-year meteorological simulations to assess the reliability and practical feasibility of the proposed system.

Funding

This research was funded by the Deanship of Research and Graduate Studies at King Khalid University through the Large Research Groups Program (Grant No. RGP2/353/47).

Data Availability Statement

The hourly meteorological records from the Abha–TVTC and Jazan University stations were obtained from the K.A.CARE Renewable Resource Monitoring and Mapping (RRMM) program [68]. The original meteorological records are subject to K.A.CARE data-use restrictions and cannot be redistributed without permission. K.A.CARE provides these records free of charge to researchers and faculty members of Saudi universities as research support, and eligible researchers may request them directly from K.A.CARE. The Python model, simulation scripts, processed ERA5-derived datasets, Latin hypercube sensitivity analysis results, and supporting numerical outputs will be made publicly available through Zenodo upon deposition, with the repository DOI provided before publication. Any meteorological input data included in the repository will be limited to information that can be lawfully shared under the applicable data-use terms. The Copernicus GLO-30 digital elevation model [69] and ERA5 reanalysis datasets [77,80] are publicly accessible from their respective providers.

Acknowledgments

The authors extend their appreciation to the Deanship of Research and Graduate Studies at King Khalid University for funding this work through the Large Research Groups Program under grant number RGP2/353/47.

Conflicts of Interest

The author declares no conflicts of interest. The funder had no role in the study design; data collection, analysis, or interpretation; manuscript preparation; or the decision to publish the results.

Nomenclature and Abbreviations

SymbolMeaningUnit
Ah, ArCollector plan area, roof aream2
AchChimney cross-sectionm2
ak, NTUNumber of transfer units of collector cell k; of the whole collector–
cpSpecific heat of airJ kg−1 K−1
DChimney diameterm
Dn, Dh, GhDNI, DHI, GHIW m−2
EAnnual energyGWh
Eflat, EinclAnnual energy of the flat and of the inclined plantGWh
f, τFraction of the absorbed flux stored in the ground and storage time constant (Section 5.7)–, h
fc, fchFriction factors (collector, chimney)–
GPOAIrradiance on the roofW m−2
gGravitational accelerationm s−2
Hc, Hs, HeqChimney height, terrain rise, equivalent chimney heightm
HrefElevation of the station above the collector inlet in the reference plant (Hs + Hc)m
hRoof clear heightm
Kin, Kturn, KexitEntrance, turning, exit loss coefficients–
LsSlope lengthm
ṁMass flow ratekg s−1
Naz, nNumber of azimuths in the irradiance average; number of radial cells–
PElectrical powerMW
p, pa, pin, pstPressure: general, ambient, at the collector inlet, at the stationPa
Qabs, Qair, Qwall, WbAbsorbed heat, heat added to the air, chimney wall loss, buoyancy work (Section 3.8)GWh
RGas constant of airJ kg−1 K−1
rm, ΔrMean radius and radial width of a collector cellm
Ri, RoInner, outer plan radiusm
T, Ta, Th, Tin, TstTemperature: general, ambient, internal air, at the collector inlet, at the stationK
TJ, TAAir temperature at Jazan and at AbhaK
Ucol, UchRoof, chimney-wall loss coefficientsW m−2 K−1
vVelocitym s−1
xDistance along the slopem
zElevation above the collector inletm
βSlope inclination°
Γ, ΓeffAmbient lapse rate; effective surface lapse rate between the two stationsK km−1
γs, γpSolar azimuth, azimuth of the roof normal°
ΔAk, Δzk, ΔtRoof area and elevation step of cell k; time step (1 h)m2, m, h
Δpb, Δpt, ΔplossDriving pressure, turbine pressure drop, pressure lossesPa
ηopt, ηTG, ηsysOptical, turbine–generator, overall efficiency–
θ, θcol, θtop, θ0Excess temperature over ambient: general, at the collector throat, at the chimney outlet, at the chimney base (=θcol)K
θoutExcess temperature at the collector outletK
θz, θiSolar zenith, incidence angle°
λTurbine pressure fraction Δpt/Δpb–
ρ, ρa, ρh, ρch,0Density: general, ambient, internal air, internal air at the chimney basekg m−3
ρgGround albedo–
φCollector opening angle°
CFDComputational fluid dynamics–
DEMDigital elevation model–
DHIDiffuse horizontal irradiance–
DNIDirect normal irradiance–
ERA5ECMWF fifth-generation atmospheric reanalysis–
GHIGlobal horizontal irradiance–
GSAGlobal sensitivity analysis–
ISAInternational standard atmosphere–
K.A.CAREKing Abdullah City for Atomic and Renewable Energy–
POAPlane of array (the collector roof)–
PRCCPartial rank correlation coefficient–
RRMMRenewable Resource Monitoring and Mapping programme–
SCPPSolar chimney power plant–
SRRCStandardized rank regression coefficient–
TVTCTechnical and Vocational Training Corporation–

References

  1. Argaam. Saudi Arabia Targets 130 GW in Renewable Energy Capacity: Minister [Statement by the Minister of Energy, Prince Abdulaziz bin Salman, at the Iktva Forum & Exhibition]. Available online: https://www.argaam.com/en/article/articledetail/id/1781918 (accessed on 13 January 2025).
  2. World Bank Group; Energy Sector Management Assistance Program (ESMAP); Solargis. Global Solar Atlas 2.0: Solar Resource Map of Saudi Arabia—Global Horizontal Irradiation (GHI), Long-Term Average 1999–2018 [Dataset/Map]; World Bank: Washington, DC, USA, 2019; Available online: https://globalsolaratlas.info (accessed on 13 January 2025).
  3. Haaf, W.; Friedrich, K.; Mayr, G.; Schlaich, J. Solar chimneys. Part I: Principle and construction of the pilot plant in Manzanares. Int. J. Sol. Energy 1983, 2, 3–20. [Google Scholar] [CrossRef] [Scilit]
  4. Haaf, W. Solar chimneys: Part II: Preliminary test results from the Manzanares pilot plant. Int. J. Sol. Energy 1984, 2, 141–161. [Google Scholar] [CrossRef] [Scilit]
  5. Schlaich, J. The Solar Chimney: Electricity from the Sun; Edition Axel Menges: Stuttgart, Germany, 1995. [Google Scholar]
  6. Schlaich, J.; Bergermann, R.; Schiel, W.; Weinrebe, G. Design of commercial solar updraft tower systems—Utilization of solar induced convective flows for power generation. J. Sol. Energy Eng. 2005, 127, 117–124. [Google Scholar] [CrossRef] [Scilit]
  7. Bernardes, M.A.d.S.; Voß, A.; Weinrebe, G. Thermal and technical analyses of solar chimneys. Sol. Energy 2003, 75, 511–524. [Google Scholar] [CrossRef] [Scilit]
  8. Pretorius, J.P.; Kröger, D.G. Critical evaluation of solar chimney power plant performance. Sol. Energy 2006, 80, 535–544. [Google Scholar] [CrossRef] [Scilit]
  9. Pretorius, J.P.; Kröger, D.G. Solar chimney power plant performance. J. Sol. Energy Eng. 2006, 128, 302–311. [Google Scholar] [CrossRef] [Scilit]
  10. Kröger, D.G.; Blaine, D. Analysis of the driving potential of a solar chimney power plant. R D J. S. Afr. Inst. Mech. Eng. 1999, 15, 85–94. [Google Scholar]
  11. von Backström, T.W.; Gannon, A.J. Compressible flow through solar power plant chimneys. J. Sol. Energy Eng. 2000, 122, 138–145. [Google Scholar] [CrossRef] [Scilit]
  12. Gannon, A.J.; von Backström, T.W. Solar chimney cycle analysis with system loss and solar collector performance. J. Sol. Energy Eng. 2000, 122, 133–137. [Google Scholar] [CrossRef] [Scilit]
  13. Pasumarthi, N.; Sherif, S.A. Experimental and theoretical performance of a demonstration solar chimney model—Part I: Mathematical model development. Int. J. Energy Res. 1998, 22, 277–288. [Google Scholar] [CrossRef]
  14. Zhou, X.; Yang, J.; Xiao, B.; Hou, G.; Xing, F. Analysis of chimney height for solar chimney power plant. Appl. Therm. Eng. 2009, 29, 178–185. [Google Scholar] [CrossRef] [Scilit]
  15. Koonsrisuk, A.; Chitsomboon, T. Mathematical modeling of solar chimney power plants. Energy 2013, 51, 314–322. [Google Scholar] [CrossRef] [Scilit]
  16. Fluri, T.P.; von Backström, T.W. Performance analysis of the power conversion unit of a solar chimney power plant. Sol. Energy 2008, 82, 999–1008. [Google Scholar] [CrossRef] [Scilit]
  17. Ninic, N. Available energy of the air in solar chimneys and the possibility of its ground-level concentration. Sol. Energy 2006, 80, 804–811. [Google Scholar] [CrossRef] [Scilit]
  18. Zhou, X.; Wang, F.; Ochieng, R.M. A review of solar chimney power technology. Renew. Sustain. Energy Rev. 2010, 14, 2315–2338. [Google Scholar] [CrossRef] [Scilit]
  19. Al-Kayiem, H.H.; Aja, O.C. Historic and recent progress in solar chimney power plant enhancing technologies. Renew. Sustain. Energy Rev. 2016, 58, 1269–1292. [Google Scholar] [CrossRef] [Scilit]
  20. Nizetic, S.; Ninic, N.; Klarin, B. Analysis and feasibility of implementing solar chimney power plants in the Mediterranean region. Energy 2008, 33, 1680–1690. [Google Scholar] [CrossRef] [Scilit]
  21. Pretorius, J.P.; Kröger, D.G. The influence of environment on solar chimney power plant performance. R D J. S. Afr. Inst. Mech. Eng. 2009, 25, 1–9. [Google Scholar]
  22. Zhou, X.; Xu, Y. Solar updraft tower power generation. Sol. Energy 2014, 128, 95–125. [Google Scholar] [CrossRef] [Scilit]
  23. Zhou, X.; Yuan, S.; Bernardes, M.A.d.S. Sloped-collector solar updraft tower power plant performance. Int. J. Heat Mass Transf. 2013, 66, 798–807. [Google Scholar] [CrossRef] [Scilit]
  24. Zhou, X.; Xu, Y.; Yuan, S.; Chen, R.; Song, B. Pressure and power potential of sloped-collector solar updraft tower power plant. Int. J. Heat Mass Transf. 2014, 75, 450–461. [Google Scholar] [CrossRef] [Scilit]
  25. von Allwörden, H.; Gasser, I.; Kamboh, M.J. Modeling, simulation and optimization of general solar updraft towers. Appl. Math. Model. 2018, 64, 265–284. [Google Scholar] [CrossRef] [Scilit]
  26. Bilgen, E.; Rheault, J. Solar chimney power plants for high latitudes. Sol. Energy 2005, 79, 449–458. [Google Scholar] [CrossRef] [Scilit]
  27. Cao, F.; Zhao, L.; Guo, L. Simulation of a sloped solar chimney power plant in Lanzhou. Energy Convers. Manag. 2011, 52, 2360–2366. [Google Scholar] [CrossRef] [Scilit]
  28. Cao, F.; Zhao, L.; Li, H.; Guo, L. Performance analysis of conventional and sloped solar chimney power plants in China. Appl. Therm. Eng. 2013, 50, 582–592. [Google Scholar] [CrossRef] [Scilit]
  29. Cao, F.; Li, H.; Zhang, Y.; Zhao, L. Numerical simulation and comparison of conventional and sloped solar chimney power plants: The case for Lanzhou. Sci. World J. 2013, 2013, 852864. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Li, Q.; Fan, X.; Xin, X.; Chao, J.; Zhou, Y. Performance study of solar chimney power plant system with a sloped collector. Key Eng. Mater. 2013, 561, 597–603. [Google Scholar] [CrossRef] [Scilit]
  31. Panse, S.V.; Jadhav, A.S.; Gudekar, A.S.; Joshi, J.B. Inclined solar chimney for power production. Energy Convers. Manag. 2011, 52, 3096–3102. [Google Scholar] [CrossRef] [Scilit]
  32. Koonsrisuk, A. Mathematical modeling of sloped solar chimney power plants. Energy 2012, 47, 582–589. [Google Scholar] [CrossRef] [Scilit]
  33. Koonsrisuk, A. Comparison of conventional solar chimney power plants and sloped solar chimney power plants using second law analysis. Sol. Energy 2013, 98, 78–84. [Google Scholar] [CrossRef] [Scilit]
  34. Baral, S. Mathematical evaluation of sloped solar chimney power plant for power generation in different regions of Nepal. Int. J. Low.-Carbon Technol. 2021, 16, 620–627. [Google Scholar] [CrossRef] [Scilit]
  35. Zhou, X.; Yang, J. A novel solar thermal power plant with floating chimney stiffened onto a mountainside and potential of the power generation in China’s deserts. Heat Transf. Eng. 2009, 30, 400–407. [Google Scholar] [CrossRef] [Scilit]
  36. Zhou, X.; Xu, Y.; Huang, Y. Novel concept of enhancing the performance of sloped solar collector by using natural anabatic winds. Int. J. Heat Mass Transf. 2016, 102, 1356–1361. [Google Scholar] [CrossRef] [Scilit]
  37. Gholamalizadeh, E.; Kim, M.-H. CFD (computational fluid dynamics) analysis of a solar-chimney power plant with inclined collector roof. Energy 2016, 107, 661–667. [Google Scholar] [CrossRef] [Scilit]
  38. Hassan, A.; Ali, M.; Waqas, A. Numerical investigation on performance of solar chimney power plant by varying collector slope and chimney diverging angle. Energy 2018, 142, 411–425. [Google Scholar] [CrossRef] [Scilit]
  39. Keshari, S.R.; Chandramohan, V.P.; Das, P. A 3D numerical study to evaluate optimum collector inclination angle of Manzanares solar updraft tower power plant. Sol. Energy 2021, 226, 455–467. [Google Scholar] [CrossRef] [Scilit]
  40. Cüce, E.; Mert Cüce, P.; Sen, H.; Sudhakar, K.; Berardi, U.; Serencam, U. Impacts of ground slope on main performance figures of solar chimney power plants: A comprehensive CFD research with experimental validation. Int. J. Photoenergy 2021, 2021, 6612222. [Google Scholar] [CrossRef] [Scilit]
  41. Cuce, P.M.; Cuce, E.; Mandal, D.K.; Gayen, D.K.; Asif, M.; Bouabidi, A.; Alshahrani, S.; Prakash, C.; Soudagar, M.E.M. ANN and CFD driven research on main performance characteristics of solar chimney power plants: Impact of chimney and collector angle. Case Stud. Therm. Eng. 2024, 60, 104568. [Google Scholar] [CrossRef] [Scilit]
  42. Weli, R.B.; Atrooshi, S.A.; Schwarze, R. Investigation of the performance parameters of a sloped collector solar chimney model: An adaptation for the North of Iraq. Renew. Energy 2021, 176, 504–519. [Google Scholar] [CrossRef] [Scilit]
  43. Rahimi-Larki, M.; Arefian, A.; Nazari, S.; Torkfar, A.; Hosseini, R.; Sarlak, H. Performance investigation of a sloped collector solar chimney system exposed to the ambient crosswind. Energy 2025, 318, 134732. [Google Scholar] [CrossRef] [Scilit]
  44. Fallah, S.H.; Valipour, M.S. Numerical investigation of a small scale sloped solar chimney power plant. Renew. Energy 2022, 183, 1–11. [Google Scholar] [CrossRef] [Scilit]
  45. Kalash, S.; Naimeh, W.; Ajib, S. Experimental investigation of the solar collector temperature field of a sloped solar updraft power plant prototype. Sol. Energy 2013, 98, 70–77. [Google Scholar] [CrossRef] [Scilit]
  46. Kalash, S.; Naimeh, W.; Ajib, S. Experimental investigation of a pilot sloped solar updraft power plant prototype performance throughout a year. Energy Procedia 2014, 50, 627–633. [Google Scholar] [CrossRef] [Scilit]
  47. Guzel, M.H.; Unal, R.E.; Kose, F. Experimental study of a micro-scale sloped solar chimney power plant. J. Mech. Sci. Technol. 2021, 35, 5773–5779. [Google Scholar] [CrossRef] [Scilit]
  48. Hussein, A.K.; Rashid, F.L.; Togun, H.; Younis, O.; Dhabab, J.M.; Al-Sharify, Z.T.; Abed, A.M.; Homod, R.Z.; Bounib, M.; Singh, D.; et al. The solar chimney development in Iraq and Saudi Arabia—A review. Environ. Technol. Rev. 2025, 14, 332–358. [Google Scholar] [CrossRef] [Scilit]
  49. Hamdan, M.O. Analysis of a solar chimney power plant in the Arabian Gulf region. Renew. Energy 2011, 36, 2593–2598. [Google Scholar] [CrossRef] [Scilit]
  50. Abdelmohimen, M.A.H.; Algarni, S.A. Numerical investigation of solar chimney power plants performance for Saudi Arabia weather conditions. Sustain. Cities Soc. 2018, 38, 1–8. [Google Scholar] [CrossRef] [Scilit]
  51. Hussain, F.M.; Rehman, S.; Al-Sulaiman, F.A. Performance analysis of a solar chimney power plant for different geographical locations of Saudi Arabia. FME Trans. 2021, 49, 64–71. [Google Scholar] [CrossRef] [Scilit]
  52. Hussain, F.M.; Al-Sulaiman, F.A. Exergy analysis of solar chimney for Saudi Arabian weather conditions. In Proceedings of the ASME 2016 10th International Conference on Energy Sustainability, Charlotte, NC, USA, 26–30 June 2016. pp. ES2016–59211. [Google Scholar] [CrossRef] [Scilit]
  53. Alshahrani, S.S. Feasibility and performance analysis of a solar chimney power plant in Abha, Saudi Arabia: Harnessing elevation and solar irradiance for sustainable energy generation. In Proceedings of the ASME International Mechanical Engineering Congress and Exposition (IMECE 2025); ASME: New York, NY, USA, 2025; Volume 6: Energy, pp. IMECE2025–165733. [Google Scholar] [CrossRef] [Scilit]
  54. Maghrebi, M.J.; Masoudi Nejad, R.; Masoudi, S. Performance analysis of sloped solar chimney power plants in the southwestern region of Iran. Int. J. Ambient Energy 2017, 38, 542–549. [Google Scholar] [CrossRef] [Scilit]
  55. Gitan, A.A.; Abdulmalek, S.H.; Dihrab, S.S. Tracking collector consideration of tilted collector solar updraft tower power plant under Malaysia climate conditions. Energy 2015, 93, 1467–1477. [Google Scholar] [CrossRef] [Scilit]
  56. Gholamalizadeh, E.; Kim, M.-H. Multi-objective optimization of a solar chimney power plant with inclined collector roof using genetic algorithm. Energies 2016, 9, 971. [Google Scholar] [CrossRef] [Scilit]
  57. Cuce, P.M.; Cuce, E.; Sen, H. Improving electricity production in solar chimney power plants with sloping ground design: An extensive CFD research. J. Sol. Energy Res. Updat. 2020, 7, 122–131. [Google Scholar] [CrossRef] [Scilit]
  58. Atia, H.; Ilinca, A.; Snoussi, A.; Boukchina, R.; Ben Brahim, A. Comparative energetic and exergetic analysis of conventional and sloped solar chimney power plants. Int. J. Energy Optim. Eng. 2020, 9, 57–73. [Google Scholar] [CrossRef] [Scilit]
  59. Semaï, H.; Bouhdjar, A. Effect of slope tower angle and thermal storage media on flexibility solar chimney power plant performance. Environ. Prog. Sustain. Energy 2021, 40, e13646. [Google Scholar] [CrossRef] [Scilit]
  60. Das, P.; Chandramohan, V.P. Experimental studies of a laboratory scale inclined collector solar updraft tower plant with thermal energy storage system. J. Build. Eng. 2021, 41, 102394. [Google Scholar] [CrossRef] [Scilit]
  61. Lorestani, H.Z.; Valipour, M.S. Numerical investigation of a sloped solar chimney power plant: A three-dimensional study. Chem. Eng. Commun. 2023, 210, 756–772. [Google Scholar] [CrossRef] [Scilit]
  62. Weli, R.B.; Atrooshi, S.A.; Schwarze, R. Design characteristics and validation of the turbine model—Case of development of turbine effect in sloped collector solar chimney plant. Energy Rep. 2023, 9, 2087–2101. [Google Scholar] [CrossRef] [Scilit]
  63. Mandal, D.K.; Biswas, N.; Manna, N.K.; Benim, A.C. Impact of chimney divergence and sloped absorber on energy efficacy of a solar chimney power plant (SCPP). Ain Shams Eng. J. 2024, 15, 102390. [Google Scholar] [CrossRef] [Scilit]
  64. Benettayeb, Y.; Benbouali, A.; Tahri, T.; Cüce, E. Performance analysis of the impact of sloped absorber dimensions on the performance of solar chimney power plants. J. Therm. Anal. Calorim. 2025, 150, 9561–9571. [Google Scholar] [CrossRef] [Scilit]
  65. Atrooshi, S.A. Geometry adaptation and system integration of a solar updraft tower: Insights from a decade of inclusive synthesis research program. Energies 2026, 19, 4079. [Google Scholar] [CrossRef] [Scilit]
  66. Lorestani, H.Z.; Valipour, M.S. Numerical investigation of the performance of a sloped solar chimney power plant: Design parameters modification effects. Int. Commun. Heat Mass Transf. 2026, 178, 112011. [Google Scholar] [CrossRef] [Scilit]
  67. International Civil Aviation Organization (ICAO). Manual of the ICAO Standard Atmosphere (Extended to 80 Kilometres/262,500 Feet), 3rd ed.; Doc 7488/3; ICAO: Montréal, QC, Canada, 1993. [Google Scholar]
  68. King Abdullah City for Atomic and Renewable Energy (K.A.CARE). Renewable Resource Monitoring and Mapping (RRMM) Program: Renewable Resource Atlas of Saudi Arabia. Solar Resource Monitoring Data for Abha–TVTC and Jazan University Stations, January 2021–August 2022 [dataset]. Available online: https://rratlas.kacare.gov.sa (accessed on 13 January 2025).
  69. European Space Agency (ESA). Copernicus DEM—Global and European Digital Elevation Model (GLO-30). Dataset; European Space Agency (ESA): Paris, France, 2021. Available online: https://doi.org/10.5270/ESA-c5d3d65?utm_source=chatgpt.com (accessed on 13 January 2025).
  70. Michalsky, J.J. The Astronomical Almanac’s algorithm for approximate solar position (1950–2050). Sol. Energy 1988, 40, 227–235. [Google Scholar] [CrossRef] [Scilit]
  71. Erbs, D.G.; Klein, S.A.; Duffie, J.A. Estimation of the diffuse radiation fraction for hourly, daily and monthly-average global radiation. Sol. Energy 1982, 28, 293–302. [Google Scholar] [CrossRef] [Scilit]
  72. Duffie, J.A.; Beckman, W.A. Solar engineering of thermal processes, 4th ed.; John Wiley & Sons: Hoboken, NJ, USA, 2013. [Google Scholar] [CrossRef] [Scilit]
  73. Liu, B.Y.H.; Jordan, R.C. The interrelationship and characteristic distribution of direct, diffuse and total solar radiation. Sol. Energy 1960, 4, 1–19. [Google Scholar] [CrossRef] [Scilit]
  74. Helton, J.C.; Davis, F.J. Latin hypercube sampling and the propagation of uncertainty in analyses of complex systems. Reliab. Eng. Syst. Saf. 2003, 81, 23–69. [Google Scholar] [CrossRef] [Scilit]
  75. Saltelli, A.; Ratto, M.; Andres, T.; Campolongo, F.; Cariboni, J.; Gatelli, D.; Saisana, M.; Tarantola, S. Global Sensitivity Analysis: The Primer; John Wiley & Sons: Chichester, UK, 2008. [Google Scholar] [CrossRef] [Scilit]
  76. Marino, S.; Hogue, I.B.; Ray, C.J.; Kirschner, D.E. A methodology for performing global uncertainty and sensitivity analysis in systems biology. J. Theor. Biol. 2008, 254, 178–196. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  77. Hersbach, H.; Bell, B.; Berrisford, P.; Hirahara, S.; Horányi, A.; Muñoz-Sabater, J.; Nicolas, J.; Peubey, C.; Radu, R.; Schepers, D.; et al. The ERA5 global reanalysis. Q. J. R. Meteorol. Soc. 2020, 146, 1999–2049. [Google Scholar] [CrossRef] [Scilit]
  78. Copernicus Climate Change Service (C3S). *ERA5 Hourly Data on Single Levels from 1940 to Present* [Dataset]; Copernicus Climate Data Store: Reading, UK, 2018. [Google Scholar] [CrossRef]
  79. Ghazal, A.M.F. Vegetation patterns and plant communities distribution along an altitudinal gradient at Asir Mountain, southwest Saudi Arabia. Pak. J. Bot. 2015, 47, 1377–1389. [Google Scholar]
  80. Copernicus Climate Change Service (C3S). *ERA5 Hourly Data on Pressure Levels from 1940 to Present* [Dataset]; Copernicus Climate Data Store: Reading, UK, 2018. [Google Scholar] [CrossRef]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.