Skip to Content
EnergiesEnergies
  • Article
  • Open Access

20 November 2026

30 Pages

Vertical-Axis Versus Horizontal-Axis Wind Turbines: A Comparative Analysis of Aerodynamic Forces, Torque, and Power Under Common Reference Conditions

,
and
Faculty of Civil Engineering and Transport, Cracow University of Technology, 31-155 Cracow, Poland
*
Author to whom correspondence should be addressed.
Energies2026, 19(22), 5629;https://doi.org/10.3390/en19225629 
(registering DOI)
This article belongs to the Special Issue New Trends in Wind Energy and Wind Turbines

Abstract

This study presents a comparative performance analysis of horizontal-axis wind turbines (HAWTs) and controlled-pitch vertical-axis wind turbines (VAWTs) using a combination of wind tunnel results and a simplified analytical framework. The objective is to compare both concepts in terms of aerodynamic forces, rotor torque and power, and selected structural and operational characteristics under common reference conditions. The comparison assumes the same swept area, wind speed, blade number, blade width, tangential blade velocity, and maximum aerodynamic load intensity. Two VAWT geometries satisfying the equal-swept-area condition are considered. In variant (1), the blade height equals the HAWT rotor radius (h = R) and the VAWT blade-axis radius is r = 1.57R, resulting in a low and wide rotor. In variant (2), the VAWT blade-axis radius equals the HAWT rotor radius (r = R) and the blade height is h = 1.57R, resulting in a more slender rotor. Wind tunnel tests of a three-bladed VAWT with mechanically controlled blade pitch define the operating range adopted in the analytical model; measured power coefficients reached 0.6 at tip-speed ratios below 2.5. The comparison shows that the HAWT drag force is twice that of VAWT variant (1) and 1.27 times that of variant (2), while the resultant side force is zero for both three-bladed configurations. The VAWT-to-HAWT torque ratio is 1.89 for both variants. Variant (1) gives the same rotor power as the HAWT, whereas variant (2) gives 50% higher rotor power. The structural comparison also shows lower blade bending moments and support forces for the two-end-supported VAWT blades. The adopted simplified analytical framework provides a consistent basis for comparing the aerodynamic, structural, and operational characteristics of HAWT and VAWT configurations under common reference conditions. The results offer approximate comparative estimates that highlight the influence of the adopted geometric and aerodynamic assumptions and provide a basis for preliminary engineering assessments of the considered turbine concepts.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.