Mitigating the Cold-Pane Effect: Empirical Evaluation of Active Glazing for Enhanced Thermal Comfort in Near-Zero-Energy Buildings

Faculty of Environmental Engineering, Geodesy, and Renewable Energy, Kielce University of Technology, Aleja Tysiąclecia Państwa Polskiego, 7, 25-314 Kielce, Poland

Abstract

The transition to near-zero-energy buildings requires advanced envelopes to mitigate winter thermal losses and the “cold-pane” effect inherent to passive highly glazed façades. This study empirically evaluates an active triple-glazed unit with an integrated flexible heating foil to enhance thermal comfort. A dual-zone climatic chamber simulated severe sub-zero conditions down to −25 °C, utilizing high-resolution thermography, heat-flux sensor arrays, and Fanger’s criteria to quantify conjugate heat transfer and local discomfort. The results indicate that passive operation at −25 °C depresses inner surface temperatures, yielding severe perimeter dissatisfaction (predicted percentage of dissatisfied, PPD > 20%) and restricting the permissible window-to-wall ratio (WWR) to 22.7% to meet Category A comfort standards. Conversely, activating the heating setpoint to 40 °C establishes a near-adiabatic thermal barrier that neutralizes radiant asymmetry, suppresses convective downdraughts, and restores microclimatic stability (PPD < 10%). In conclusion, dynamic electro-thermal modulation effectively eliminates the perimeter cold sink, theoretically permitting up to a 100% WWR ceiling and relaxing the restrictive architectural constraints of conventional passive glazing under extreme winter conditions.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.