Abstract
To address the continuously increasing thermal load of aero-engines, fuel/lubricating oil heat exchangers are evolving toward higher heat transfer efficiency, lower flow resistance, and lighter weight. This paper numerically compares the thermo-hydraulic performance of a conventional shell-and-tube heat exchanger (STHE) and three typical types of printed-circuit heat exchangers (PCHEs) for aero-engine applications. The three PCHE configurations fall into two categories based on their flow channel geometries: continuous-rib structures (straight and Z channels) and a discontinuous-rib structure (airfoil channel). All models are established under identical core volume and equivalent diameter to ensure a fair comparison. The results show that the airfoil-channel PCHE achieves the best overall performance. Compared with the STHE, it increases the heat transfer rate by 63%, reduces flow resistance by 76%, expands heat transfer area by 125%, and reduces operating weight by 60%. Flow field analysis reveals that the airfoil channel enables efficient heat transfer without excessive flow resistance through three key mechanisms: leading-edge impingement, periodic boundary layer reconstruction, and uniform flow mixing. This study provides an important reference for the selection and optimization of high-efficiency compact heat exchangers in aero-engines.
1. Introduction
In an aero-engine, the lubrication system plays a critical role in providing lubrication and heat dissipation for transmission components. Lubricating oil is continuously supplied to the surfaces of bearings and transmission gears, removing frictional heat while simultaneously preheating the fuel. At the heart of this lubrication system lies the fuel/lubricating oil heat exchanger, which achieves fuel preheating and oil cooling through heat exchange between the two fluids. Consequently, the thermal performance of this heat exchanger directly affects the overall temperature control of the lubrication system, thereby playing an essential role in ensuring both the safe operation and operational efficiency of the aero-engine.
Shell-and-tube heat exchangers (STHEs) are the most widely used heat exchangers in the thermal engineering field, and extensive research has been conducted on their structural configurations and arrangements. Kallannavar et al. [1] experimentally investigated the effects of four typical tube layouts (30°, 45°, 60°, and 90°) on the thermodynamic performance of STHEs. They found that the 30° triangular arrangement yields the optimal heat transfer performance, providing a valuable benchmark for subsequent numerical studies. Building on this mature body of knowledge, STHEs have become the most commonly adopted configuration for aero-engine fuel/lubricating oil heat exchangers. Gu et al. [2] evaluated the shell-side heat transfer characteristics of a shell-and-tube fuel/lubricating oil heat exchanger using the Kern method, the Bell–Delaware method, and the dividable simulation method. Their results indicated that the dividable simulation method, which is based on flow characteristics, offers higher accuracy and can effectively meet the design requirements of the lubrication system. Li et al. [3] numerically analyzed and optimized the thermodynamic performance of an aero-engine fuel/lubricating oil STHE using HTRI software. They reported that the tube-side thermal resistance dominates the total thermal resistance, and that inserting twisted tapes can effectively improve the thermodynamic performance.
Despite their cost-effectiveness and technological maturity, conventional STHEs are increasingly unable to meet the stringent requirements of modern aero-engine fuel and lubricating oil heat exchangers. With the continuously increasing thermal load of aero-engines, there is a growing demand for high heat transfer efficiency, low flow resistance, lightweight design, and structural compactness, which conventional STHEs can no longer adequately satisfy. In response to these challenges, the printed-circuit heat exchanger (PCHE), fabricated via photochemical etching and diffusion bonding, has emerged as a highly promising candidate for advanced thermal management systems. Compared with conventional STHEs, a PCHE achieves the same thermal duty with only one-seventh of the volume [4,5,6]. Moreover, its monolithic core construction not only enhances structural integrity but also ensures superior safety and operational stability under extreme conditions, including those involving supercritical fluids [7,8,9]. These compelling attributes render the PCHE a valuable reference for the selection of fuel/lubricating oil heat exchangers for aero-engine applications. However, despite these attractive performance characteristics, the PCHE market has long been dominated by the UK-based company Heatric, primarily owing to the technical complexities associated with PCHE design and manufacturing. Encouragingly, significant progress has been made in China in recent years across key areas such as heat exchanger design, photochemical etching, and diffusion bonding. This progress has now enabled the domestic independent production of PCHEs.
Based on flow channel geometries, PCHEs can be broadly divided into two categories: continuous-rib and discontinuous-rib structures. Continuous-rib configurations mainly include straight channels, Z (zigzag) channels, sinusoidal channels, trapezoidal channels, and other enhanced structures. Liu et al. [10] experimentally studied straight-channel PCHEs with supercritical carbon dioxide (sCO2) as the working fluid and found that convective heat transfer is significantly enhanced when sCO2 is cooled from the gas-like region to the pseudo-critical region. Kim et al. [11,12,13] conducted numerical simulations and experiments on Z PCHEs with a channel inclination angle of 15°, using helium and water as working fluids. They proposed empirical correlations for the Fanning friction factor and Nusselt number over wide ranges of Reynolds and Prandtl numbers. Ma et al. [14] reported that increasing the inclination angle of Z-shaped PCHEs enhances both heat transfer and flow resistance, although this enhancement is constrained by the operating flow rate range. Chen et al. [15] pointed out that periodic disturbances at the corners of Z channels suppress fully developed flow, while the heat transfer improvement becomes negligible when the inclination angle exceeds 30°. Aneesh et al. [16] evaluated the thermodynamic performance of three wavy channel configurations (triangular, sinusoidal, and trapezoidal) and demonstrated that the trapezoidal channel achieves the highest heat transfer enhancement (up to 41%) compared with straight channels, accompanied by the largest pressure drop penalty. Wen et al. [17] explored the effects of amplitude and wavelength on the heat transfer performance of sinusoidal channels. They concluded that increasing amplitude and decreasing wavelength prolong the flow path and enlarge the effective heat transfer area, thereby improving the heat transfer rate, with the optimal performance obtained at an amplitude of 3 mm and a wavelength of 50 mm.
Discontinuous-rib structures were first proposed by Japanese scholars. A typical representative is the S-shaped fin PCHE developed by Tsuzuki et al. [18], who reported that this discontinuous structure achieves the same heat transfer performance as conventional Z-shaped channels with only one-fifth of the pressure drop. Ngo et al. [19] further confirmed that, compared with Z-shaped PCHEs, S-shaped fin PCHEs reduce the Nusselt number by only 24–34%, while the pressure drop factor is just one-fourth to one-fifth of that of the Z-type. Another typical discontinuous-rib configuration is the airfoil-channel structure, which has been widely investigated. Cui et al. [20] proposed a novel airfoil-channel configuration based on the NACA0020 profile, which exhibited better comprehensive performance: the j-factor was 2.97–6.15% higher, and the pressure drop was 0–4.07% lower than that of the original NACA0020 profile. The enhancement mechanism was well explained by the field synergy principle. Chang et al. [21] experimentally studied asymmetric airfoil fins based on the average thermal resistance ratio. Compared with counterflow, co-flow improved the comprehensive performance by 6.1%, 4.0%, and 1.8% at CO2 bulk temperatures of 38 °C, 41 °C, and 47 °C, respectively.
In recent years, further studies have advanced the understanding of thermodynamic characteristics of PCHEs with various rib structures under different operating conditions. Zhang et al. [22] numerically investigated the thermo-hydraulic performance of supercritical CO2 in PCHE channels integrated with airfoil fins and vortex-generating structures, revealing that reasonable structural integration can effectively enhance heat transfer while balancing flow resistance. Chang et al. [23] experimentally studied a mirror-symmetric channel PCHE for low-temperature waste heat recovery and achieved a thermal effectiveness of up to 0.979, demonstrating that flow rate ratio and inlet temperature are the dominant factors affecting thermal performance. Li et al. [24] numerically analyzed the thermo-hydraulic performance of Z-channel PCHEs using supercritical methane, optimized key geometric parameters including channel diameter, bending angle, and pitch number, and developed corrected correlations for Nusselt number and friction factor, with prediction deviations within ±12% and ±13%, respectively. Zheng et al. [25] numerically investigated the thermo-hydraulic performance of Hitec molten salt in airfoil-channel PCHEs, optimized geometric parameters such as airfoil profile and fin spacing, and proved that discontinuous airfoil structures significantly enhance heat transfer with a low pressure drop penalty compared with conventional channels. Xu et al. [26] numerically and experimentally studied the thermo-hydraulic performance of liquid metal/aviation kerosene PCHEs, finding that channel cross-section shape, inclination angle, and flow arrangement significantly affect heat transfer and pressure drop characteristics, and recommended a trapezoidal cross-section with a straight channel structure for optimal performance. Koca et al. [27] proposed a novel 3D-printed air-cooled PCHE fuel cooler with twisted fins and helical piping. Their results showed that the discontinuous fin structure significantly intensifies turbulence and heat transfer, increasing cooling capacity by 55.6% and reducing weight by 66% compared with conventional heat exchangers, thus verifying the great potential of enhanced fin structures in high-performance aviation heat exchangers.
Despite the substantial body of research summarized above, most existing studies focus on a single type of flow channel or a single working fluid. Critically, few studies provide a fair and direct comparison among STHEs, continuous-rib PCHEs, and discontinuous-rib PCHEs under the same geometric constraints and typical operating conditions of aero-engine fuel/lubricating oil systems. This research gap significantly limits the optimal configuration selection for practical engineering applications. To fill this gap, the present study numerically investigates the thermodynamic performance of a conventional shell-and-tube heat exchanger and three typical PCHEs for use as fuel/lubricating oil heat exchangers. All physical models are designed with the same core volume and hydraulic diameter to ensure comparability. The thermodynamic characteristics of continuous-rib structures (straight and Z channels) and a discontinuous-rib structure (airfoil channel) are compared. Detailed flow and temperature field analyses are performed to reveal the underlying heat transfer enhancement mechanisms. This study aims to provide reliable data and design guidance for the selection and optimization of high-performance, lightweight heat exchangers in advanced aero-engines.
2. Methodology
2.1. Computational Model and Simulation Settings
To ensure a fair comparison between the conventional STHE and the three PCHE configurations, all physical models were established under the same core volume (approximately 71,400–73,100 mm3) and equivalent hydraulic diameter (approximately 1.5 mm). The four heat exchanger configurations examined in this study are as follows:
- (1)
- STHE: A conventional shell-and-tube heat exchanger with a single tube pass and five shell passes equipped with segmental baffles. A total of 61 heat transfer tubes (inner diameter: 1.5 mm, wall thickness: 0.5 mm, tube pitch: 3.6 mm) were arranged in a triangular layout. The computational model is shown in Figure 1a.Figure 1. Schematic diagram of the computational models of the STHE and three types of PCHEs.
- (2)
- Straight-channel PCHE: A continuous-rib PCHE with straight semicircular channels (diameter: 2.46 mm, hydraulic diameter: 1.5 mm). The flow length is 84 mm. A unit cell modeling approach with periodic boundary conditions was adopted. The model is shown in Figure 1b and Figure 2a.Figure 2. Schematic diagram of physical models of three kinds of PCHEs: (a) straight channel; (b) Z channel; (c) airfoil channel (unit: mm).
- (3)
- (4)
For the three PCHE configurations, the unit cell modeling approach was used to represent the repeating internal structure, and periodic boundary conditions were applied on all lateral surfaces. Consequently, the comparison is based on consistent core volume and hydraulic diameter.
To improve computational efficiency while maintaining accuracy, a unit cell modeling approach was used for the three PCHEs, with periodic boundary conditions applied on all lateral surfaces to accurately capture flow and heat transfer characteristics. After defining the boundary conditions of the geometric models, polyhedral meshes were generated using Fluent Meshing 2020 R1, and boundary layer meshes were refined near the walls to improve the resolution of heat transfer and flow behavior in the near-wall region. Mesh generation for the STHE and straight-channel PCHE is shown in Figure 3.
Figure 3.
Mesh division of (a) STHE and (b) straight-channel PCHE.
Polyhedral meshes were generated for all computational domains using Fluent Meshing 2020 R1. Boundary layer mesh refinement was implemented near the solid walls to ensure a reasonable y+ value for accurate near-wall heat transfer and flow prediction. A strict grid independence test was performed for all four heat exchanger models. Taking the Z-channel PCHE as an example, four sets of mesh with increasing density were examined. The variations in heat transfer rate and cold-side pressure drop became negligible when adopting the fourth mesh scheme, indicating that the numerical results are grid-independent and meet the convergence requirement. The finally adopted mesh density balances computational accuracy and efficiency.
Grid independence verification was performed for all four heat exchanger models. Taking the Z-channel PCHE as an example, Figure 4 presents the effects of five grid sets with different densities on the predicted heat transfer rate (Q) and cold-side pressure drop (ΔP). The variations in heat transfer rate and pressure drop become negligible starting from the fourth grid set, indicating that the results are essentially independent of grid resolution and meet the grid independence requirement.
Figure 4.
Mesh independence analysis of the Z-channel PCHE. The dashed vertical line indicates the selected mesh number for subsequent simulations.
Numerical simulations were performed using ANSYS Fluent 2020 R1. The Reynolds numbers (Re) inside all three PCHEs were below the critical laminar value (Recr = 2300), so the laminar flow model was adopted. For the STHE, the Re on both the tube side and shell side are relatively high with strong flow disturbances, and thus the k-ω turbulence model was used. Periodic boundary conditions were imposed on all lateral surfaces of the PCHE unit cells. The momentum, energy, and turbulence equations were discretized using the second-order upwind scheme, and pressure–velocity coupling was handled by the Coupled algorithm.
2.2. Working Fluids and Operating Conditions
2.2.1. Thermophysical Properties
The cold-side fluid is RP-3 aviation kerosene, with properties calculated as functions of Celsius temperature (t, °C) or Kelvin temperature (T, K).
Density (ρ, kg·m−3) is calculated as
Specific heat (cp, J·kg−1·°C−1) is calculated as
Thermal conductivity (k, W·m−1·°C−1) is calculated as
Kinematic viscosity (ν, mm2·s−1) is calculated as
The hot-side fluid is Mobil Jet Oil II, with properties also expressed as functions of Celsius temperature (t, °C) or Kelvin temperature (T, K).
Density (ρ, kg·m−3) is calculated as
Specific heat (cp, J·kg−1·°C−1) is calculated as
Thermal conductivity (k, W·m−1·°C−1) is calculated as
Kinematic viscosity (ν, mm2·s−1) is calculated as
All solid walls are made of aluminum alloy, with ρ = 2719 kg·m−3, cp = 871 J·kg−1·°C−1, and k = 202.4 W·m−1·°C−1.
2.2.2. Operating Conditions
The inlet temperature of cold-side fluid (fuel) is 65 °C, and the inlet temperature of hot-side fluid (lubricating oil) is 115 °C. The mass flow rate of hot lubricating oil is fixed at 0.136 kg/s, while the mass flow rate of cold fuel varies from 0.034 to 0.136 kg/s.
2.3. Performance Evaluation Parameters
When evaluating the performance of the four heat exchangers described above, heat transfer and flow resistance characteristics are the primary concerns. The convective heat transfer coefficient (h) and flow resistance (ΔP) are the key parameters directly characterizing these two aspects of performance, with their corresponding dimensionless numbers being the Nusselt number (Nu) and the Fanning friction factor (f), respectively.
The Re, which characterizes the fluid flow regime, is defined as
Here, ρ, u, and μ are the density, velocity, and viscosity of the fluid, respectively. And Dh is the hydrodynamic diameter.
The Nu for heat transfer performance and the f for flow resistance performance are defined as
Here, k is the thermal conductivity of the fluid, ΔP is the pressure drop between the inlet and outlet of the channel, Lz is the total length of the channel in the flow direction, and U is the mean flow velocity in the channel cross-section.
To further comprehensively evaluate the overall performance of different heat exchangers, the performance evaluation criterion (PEC) is introduced and defined as follows:
Here, Nu0 and f0 refer to the Nusselt number and Fanning friction factor of the baseline STHE at the same Re. Nu and f correspond to those of the PCHE. The PEC reflects the trade-off between heat transfer enhancement and flow resistance increase at equal pumping power, enabling a consistent performance comparison across different heat exchanger configurations.
To ensure a comprehensive and fair evaluation for aero-engine applications, this study adopts multi-dimensional engineering evaluation criteria, including basic thermal–hydraulic indicators (Q, ΔP, Nu, f), comprehensive performance index (PEC), and practical aviation indicators (heat transfer area, core weight, operating weight). The overall performance is determined by the combined consideration of all indexes, rather than a single parameter.
2.4. Model Validation
To ensure the credibility of the numerical simulations, two separate validation approaches were adopted for the STHE and the PCHEs, respectively, due to their different flow regimes.
For the STHE, which operates in the turbulent regime, validation was performed against the Bell-Delaware method [28], a widely accepted semi-empirical method for shell-and-tube heat exchanger design [29]. The detailed calculation procedure, including all correction factors and intermediate steps, is provided in the Supplementary Materials. As shown in Figure 5a,b, the maximum deviations between the CFD results and the Bell–Delaware-based calculated values for the STHE are 10.43% for f × Re and 8.59% for Nu, respectively. These deviations confirm that the STHE model is sufficiently accurate for the comparative analysis in this study.
Figure 5.
Validation of numerical results: (a) f × Re and (b) Nu for the STHE (numerical vs. Bell–Delaware calculation method); (c) f × Re and (d) Nu for the Z-channel PCHE (numerical vs. the literature correlation) [11].
For the PCHEs, the numerical results were compared with the experimental correlations of Kim et al. [11], which are applicable to laminar and transitional flow (Re = 350–800). As shown in Figure 5c,d, the maximum deviations for f × Re and Nu are 4.57% and 14.51%, respectively, within the typical accuracy range reported for PCHE simulations in the literature. Considering experimental measurement errors and ambient heat losses, the numerical simulations are considered to be in good agreement with the experimental results. These validations confirm that ANSYS Fluent 2020 R1 can reproduce real thermo-hydraulic behavior with acceptable engineering accuracy (<15%) for the present fuel/oil heat exchanger simulations.
3. Results and Discussion
3.1. Effect of Configuration on Overall Heat Exchanger Performance
Key parameters of the STHE and three PCHEs are compared in Table 1. As expected, the equivalent diameter and core volume are nearly identical across all models, ensuring comparability. As shown in Table 1, the heat transfer areas of the straight-channel and Z-channel PCHEs are increased by more than 85% compared with the STHE, while that of the airfoil-channel PCHE is enhanced by as much as 125%. Weight is also a critical performance indicator for heat exchangers in aero-engine applications. In terms of both core weight and operating weight, all three PCHEs exhibit a reduction of 35–68% relative to the STHE.
Table 1.
Comparison of key parameters for these four heat exchangers.
Next, a comprehensive comparison is conducted on the flow and heat transfer performance of the four heat exchangers. As shown in Figure 6a, the straight-channel PCHE exhibits the lowest heat transfer rate under the same cold-side flow rate. This is mainly attributed to the absence of flow-disturbing structures within its channels, which allows the thermal boundary layer to fully develop and thereby reduces the convective heat transfer coefficient near the wall. The STHE outperforms only the simplest straight-channel PCHE. In contrast, the airfoil-channel PCHE achieves the highest heat transfer rate. At a maximum fuel mass flow rate (G = 0.136 kg/s), its heat transfer rate is 55% higher than that of the Z-channel PCHE and 63% higher than that of the straight-channel PCHE. Figure 6b compares the cold-side pressure drop of the four heat exchangers. At the same maximum cold-side mass flow rate, the STHE exhibits the highest pressure drop (8297.9 Pa), which is 4.13 times that of the Z-channel PCHE and 9.14 times that of the airfoil-channel PCHE, respectively. Figure 6c presents the overall thermodynamic performance of the four heat exchangers. In terms of heat transfer rate per unit pressure drop per unit operating weight, the performance ranking is: airfoil-channel PCHE > Z-channel PCHE > straight-channel PCHE > STHE. When both flow resistance and operating weight are taken into account, the STHE is clearly inferior to all three compact PCHEs, while the airfoil-channel PCHE demonstrates a distinct and overwhelming advantage.
Figure 6.
Comparison of (a) heat transfer rate, (b) cold-side pressure drop, and (c) heat transfer per operating weight for the four heat exchangers.
3.2. Effect of PCHE Structure on Heat Transfer and Flow Performance
Following the performance comparison between the STHE and PCHEs, further investigation into the structural effects among different PCHEs is of great engineering significance. The straight-channel and Z-channel PCHEs fall into the continuous-rib category, whereas the airfoil-channel PCHE represents the discontinuous-rib configuration. Figure 7 illustrates the variations in the Nu, f, and PEC with Re of the cold side for the three PCHEs. As shown in Figure 7a, the heat transfer performance ranked by Nu is as follows: airfoil channel > Z channel > straight channel. As presented in Figure 7b, the straight-channel PCHE shows the lowest f due to weak flow disturbance, whereas the Z-channel and airfoil-channel PCHEs exhibit similar trends in f. As observed in Figure 7c, the PEC values of all three PCHEs are greater than 1, indicating that their overall thermodynamic performance is superior to that of fully developed circular tube flow under laminar conditions. Among them, the airfoil-channel PCHE demonstrates the best performance. Specifically, its PEC value reaches approximately 6 at a Reynolds number of 1200.
Figure 7.
Variations of (a) Nu, (b) f and (c) PEC with Re of the cold side in three types of PCHEs.
Figure 8 further presents the variations in Nu and f along the flow direction for the three PCHEs. As shown in Figure 8a, for the straight-channel PCHE, the Nu remains consistently low except in the inlet region. The Z-channel PCHE exhibits only mild variations in Nu along the flow direction. In contrast, the airfoil-channel PCHE maintains the highest Nu level throughout, demonstrating superior heat transfer performance. As illustrated in Figure 8b, both the straight-channel and Z-channel PCHEs exhibit peak f values at the inlet, which then drop sharply downstream. The airfoil-channel PCHE shows fluctuations in its f distribution, with values comparable to those of the Z-channel PCHE. These results demonstrate that, compared with the continuous-rib Z channel, the discontinuous-rib airfoil channel (airfoil-channel PCHE) enhances heat transfer without a significant rise in flow resistance, thus yielding a distinct advantage in overall thermodynamic performance.
Figure 8.
Variations of (a) Nu, (b) f and (c) PEC with distance from the inlet in three types of PCHEs.
The superior overall performance of the airfoil-channel PCHE is concluded based on the joint evaluation of thermal–hydraulic parameters, PEC values, and weight advantages, consistent with the multi-index evaluation criteria defined in Section 2.3. This integrated judgment fully reflects the actual design requirements of high efficiency, low resistance, and lightweight for aero-engine heat exchangers.
3.3. Flow Characteristics in PCHEs
The internal flow passage of a heat exchanger fundamentally governs its heat transfer and flow performance. Therefore, a thorough analysis of flow characteristics inside PCHEs is essential for understanding their heat transfer enhancement mechanisms. As shown in Figure 9a, the main difference in velocity profiles across the straight-channel PCHE lies in the development of the near-wall boundary layer, which accounts for the simultaneous heat transfer enhancement and resistance increase in the inlet region. As shown in Figure 9b, the flow inside the Z-channel PCHE varies considerably. At line-1 (Y = 14 mm), the maximum velocity occurs in the negative X-direction, while at line-3 (Y = 21 mm), the peak velocity shifts to the positive X-direction. This indicates that the main flow of the Z channel undergoes periodic lateral deflection, accompanied by large low-velocity zones within the channel. As shown in Figure 9c, the maximum flow velocity inside the airfoil-channel PCHE is approximately 0.8 m/s, noticeably lower than that in the straight-channel and Z-channel PCHEs. This is attributed to the enlarged cross-sectional area and more uniform flow distribution. Unlike the isolated channels in continuous-rib PCHEs, the discontinuous-rib airfoil channels are interconnected within the entire plate layer, promoting uniform fluid mixing between adjacent regions and enabling efficient momentum and energy exchange. Such homogeneous mixing is also a key reason for the superior overall performance of the airfoil-channel PCHE.
Figure 9.
Velocity distribution at different positions of the (a) straight-, (b) Z- and (c) airfoil-channel PCHEs.
Figure 10 further compares the velocity vector fields of the Z-channel and airfoil-channel PCHEs. It can be seen that PCHEs with different channel configurations exhibit distinct flow characteristics. As shown in Figure 10a, the turning corners of the Z channel fail to guide the flow effectively, resulting in periodic deflection of the main flow accompanied by the formation of flow stagnation zones. This adversely affects heat transfer enhancement, and such an effect becomes more pronounced at higher flow velocities. Figure 10b illustrates the internal flow field of the airfoil-channel PCHE. In conventional channels, heat is transferred from the solid wall to the fluid and diffuses toward the core region through the boundary layer, making the flow core a weak zone for heat transfer. In contrast, the leading edge of the airfoil fin directly impinges on the core region of the upstream flow and reconstructs a new boundary layer continuously, thereby significantly strengthening heat transfer in the flow core. This advantage further supports the comparative analysis of the Nu among different heat exchangers presented earlier (Figure 7a and Figure 8a).
Figure 10.
Velocity vector diagrams of the (a) Z- and (b) airfoil-channel PCHEs.
Figure 11 presents the heat flux contours of the three PCHEs. As shown in Figure 11a, the straight-channel PCHE features no flow-disturbing structures, allowing the flow to fully develop. Consequently, the heat flux distribution is relatively uniform, with an area-averaged heat flux of 20.7 kW/m2. However, the main flow in the Z-channel PCHE deflects at the channel bends, creating a distinct unilateral high-heat-transfer region compared with the straight-channel PCHE (Figure 11b). Over the same domain, the average heat flux reaches 34.2 kW/m2, approximately 65% higher than that of the straight-channel PCHE. As discussed above, the heat transfer enhancement mechanism of the airfoil-channel PCHE differs significantly from the other two configurations. As shown in Figure 11c, high heat flux regions concentrate at the leading edges of the airfoil fins due to flow impingement and local stagnation. At the maximum flow rate, the local heat flux at the leading edge can reach 250 kW/m2. The average heat flux is 47.4 kW/m2, which is 129% higher than that of the straight-channel PCHE and 39% higher than that of the Z-channel PCHE, respectively.
Figure 11.
Heat flux contour maps of the (a) straight, (b) Z- and (c) airfoil-channel PCHEs.
4. Conclusions
A numerical comparison of the thermodynamic performance of an STHE and three PCHEs (straight-channel, Z-channel, and airfoil-channel) is conducted. The comparison is based on three specific aspects: (i) Fair baseline establishment: All models share identical core volume and equivalent hydraulic diameter, eliminating geometric and scaling effects. (ii) Multi-dimensional evaluation: These include raw thermal–hydraulic parameters (Q, ΔP), dimensionless numbers (Nu, f), comprehensive index (PEC), and engineering metrics (heat transfer area, weight). (iii) Mechanism-oriented flow analysis: Velocity distribution, velocity vector, and heat flux contours are sequentially examined to reveal how different rib structures affect boundary layer development, flow mixing, and local heat transfer. The main conclusions are drawn as follows:
- (1)
- The airfoil-channel PCHE achieves the best overall performance. Under identical core volume and equivalent diameter, it increases the heat transfer rate by 63%, reduces pressure drop to 1/4 of the STHE, expands heat transfer area by 125%, and cuts operating weight by 60%, demonstrating remarkable advantages in lightweight design and high-efficiency heat transfer.
- (2)
- The performance ranking of PCHEs is as follows: airfoil channel > Z channel > straight channel. Analysis based on the Performance Evaluation Criterion (PEC) indicates that the discontinuous-rib structure (airfoil channel) is significantly superior to continuous-rib structures in overall thermo-hydraulic performance. The straight-channel PCHE presents weak heat transfer due to insufficient flow disturbance. Although the Z-channel PCHE enhances heat transfer, it suffers from flow stagnation and increased pressure drop.
- (3)
- Flow mechanism analysis reveals the origin of performance differences. The Z channel is limited in heat transfer enhancement by flow deflection and stagnant zones. In contrast, the airfoil channel enlarges the flow area, uniformizes flow distribution, and creates local high heat flux regions via leading-edge impingement, which effectively strengthens core-region heat transfer. Meanwhile, periodic boundary layer reconstruction ensures sustained heat transfer enhancement.
This study not only reveals the flow and heat transfer mechanisms of different PCHEs through numerical analysis but also verifies the remarkable advantages of discontinuous-rib structures (especially airfoil channels) in improving comprehensive thermodynamic performance from the perspective of engineering applicability. The results provide a theoretical basis and data support for the selection and optimization of fuel-lubricating oil heat exchangers under high-load conditions, and possess positive engineering significance and academic value for advancing the thermal systems of China’s aero-engines toward higher efficiency, stronger reliability, and lighter weight. This study fills an important research gap by providing a comprehensive and direct quantitative comparison of different heat exchanger types under the same constraints. The identified advantages of discontinuous-rib structures, particularly the airfoil-channel PCHE, offer clear and practical insights for the design and optimization of high-efficiency, lightweight heat exchangers in advanced aero-engine applications.
For practical aerospace applications, the manufacturing challenges of PCHEs, including precision chemical etching (channel tolerance within ±0.05 mm), diffusion bonding quality control, micro-channel leak detection, and associated costs, etc. These challenges must also be carefully considered. Currently, the production cost of PCHEs is much higher than that of conventional STHEs. Future work should systematically evaluate these manufacturability and economic factors, as well as develop cost-effective fabrication techniques, to bridge the gap between laboratory-scale performance demonstration and practical aerospace certification. In addition, a systematic parametric sensitivity analysis and geometric structure optimization of the PCHE channels will be carried out to further improve their thermo-hydraulic performance and lightweight potential for aero-engine thermal management systems.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/en19122941/s1.
Author Contributions
Conceptualization, H.J.; methodology, H.J.; software, H.J., Q.H. and W.L.; validation, G.L.; formal analysis, H.J. and Q.H.; investigation, G.L., Q.H. and W.L.; data curation, G.L.; writing—original draft preparation, H.J.; writing—review and editing, G.L. and Y.L.; supervision, G.L. and Y.L. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
The data presented in this study are available on request to the authors and will not be made public due to privacy concerns.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Kallannavar, S.; Mashyal, S.; Rajangale, M. Effect of Tube Layout on the Performance of Shell and Tube Heat Exchangers. Mater. Today Proc. 2020, 27, 263–267. [Google Scholar] [CrossRef] [Scilit]
- Gu, J. Calculating method and experimental verification of heat transfer characteristics for tube and shell type fuel and oil heat exchanger. Aeroengine 2013, 39, 65–69. [Google Scholar]
- Li, G.; Shen, H.; Zeng, G.; Jiang, H.; Li, W.; An, S. Optimizing the Thermodynamic Performance of the Fuel/Lubricating Oil Heat Exchanger for an Aeroengine. Energies 2025, 18, 4955. [Google Scholar] [CrossRef] [Scilit]
- Xin, F.; Ma, T.; Chen, Y.; Wang, Q. Study on Chemical Spray Etching of Stainless Steel for Printed Circuit Heat Exchanger Channels. Nucl. Eng. Des. 2019, 341, 91–99. [Google Scholar] [CrossRef] [Scilit]
- Saranam, V.R.; Paul, B.K. Feasibility of Using Diffusion Bonding for Producing Hybrid Printed Circuit Heat Exchangers for Nuclear Energy Applications. Procedia Manuf. 2018, 26, 560–569. [Google Scholar] [CrossRef] [Scilit]
- Rozman, K.; Saranam, V.; Doğan, Ö.; Paul, B.; Hawk, J. Effect of Specimen Orientation on the Mechanical Performance of Diffusion Bonded 316 Stainless Steel for Hybrid Printed Circuit Heat Exchangers. J. Mater. Eng. Perform. 2021, 30, 7950–7957. [Google Scholar] [CrossRef] [Scilit]
- Jin, W.; Wang, L.; Deng, L.; Zhang, L.; Che, D. Thermal-Hydraulic Performance of Novel Slotted Fusiform Fin Printed Circuit Heat Exchanger for Supercritical CO2 Brayton Cycle. Appl. Therm. Eng. 2024, 248, 123104. [Google Scholar] [CrossRef] [Scilit]
- Jin, F.; Yuan, D.; Chen, D.; Hu, L.; Huang, Y.; Bu, S. Experimental Study on Cooling Heat Transfer Performance of Supercritical CO2 in Zigzag Printed Circuit Heat Exchanger. Int. J. Heat Mass Transf. 2023, 215, 124538. [Google Scholar] [CrossRef] [Scilit]
- Wang, J.; Yan, X.; Lu, M.; Sun, Y.; Wang, J. Structural Assessment of Printed Circuit Heat Exchangers in Supercritical CO2 Waste Heat Recovery Systems for Ship Applications. J. Therm. Sci. 2022, 31, 689–700. [Google Scholar] [CrossRef] [Scilit]
- Liu, S.; Huang, Y.; Wang, J.; Liu, R.; Zang, J. Experimental Study of Thermal-Hydraulic Performance of a Printed Circuit Heat Exchanger with Straight Channels. Int. J. Heat Mass Transf. 2020, 160, 120109. [Google Scholar] [CrossRef] [Scilit]
- Kim, I.H.; No, H.C.; Lee, J.I.; Jeon, B.G. Thermal Hydraulic Performance Analysis of the Printed Circuit Heat Exchanger Using a Helium Test Facility and CFD Simulations. Nucl. Eng. Des. 2009, 239, 2399–2408. [Google Scholar] [CrossRef] [Scilit]
- Kim, I.H.; No, H.C. Thermal Hydraulic Performance Analysis of a Printed Circuit Heat Exchanger Using a Helium-Water Test Loop and Numerical Simulations. Appl. Therm. Eng. 2011, 31, 4064–4073. [Google Scholar]
- Kim, I.H.; No, H.C. Thermal-Hydraulic Physical Models for a Printed Circuit Heat Exchanger Covering He, He-CO2 Mixture, and Water Fluids Using Experimental Data and CFD. Exp. Therm. Fluid Sci. 2013, 48, 213–221. [Google Scholar]
- Ma, T.; Li, L.; Xu, X.; Chen, Y.; Wang, Q. Study on Local Thermal-Hydraulic Performance and Optimization of Zigzag-type Printed Circuit Heat Exchanger at High Temperature. Energy Convers. Manag. 2015, 104, 55–66. [Google Scholar]
- Chen, M.; Sun, X.; Christensen, R.N. Thermal-hydraulic Performance of Printed Circuit Heat Exchangers with Zigzag Flow Channels. Int. J. Heat Mass Transf. 2019, 130, 356–367. [Google Scholar] [CrossRef] [Scilit]
- Aneesh, A.; Sharma, A.; Srivastava, A.; Chaudhury, P. Effects of Wavy Channel Configurations on Thermal-Hydraulic Characteristics of a Printed Circuit Heat Exchanger (PCHE). Int. J. Heat Mass Transf. 2018, 118, 304–315. [Google Scholar] [CrossRef] [Scilit]
- Wen, Z.; Lv, Y.; Li, Q.; Zhou, P. Numerical Study on Heat Transfer Behavior of Wavy Channel Supercritical CO2 Printed Circuit Heat Exchangers with Different Amplitude and Wavelength Parameters. Int. J. Heat Mass Transf. 2020, 147, 118922. [Google Scholar] [CrossRef] [Scilit]
- Tsuzuki, N.; Kato, Y.; Ishiduka, T. High Performance Printed Circuit Heat Exchanger. Appl. Therm. Eng. 2007, 27, 1702–1707. [Google Scholar] [CrossRef] [Scilit]
- Ngo, T.L.; Kato, Y.; Nikitin, K.; Ishizuka, T. Heat Transfer and Pressure Drop Correlations of Microchannel Heat Exchangers with S-Shaped and Zigzag Fins for Carbon Dioxide Cycles. Exp. Therm. Fluid Sci. 2007, 32, 560–570. [Google Scholar] [CrossRef] [Scilit]
- Cui, X.; Guo, J.; Huai, X.; Cheng, K.; Zhang, H.; Xiang, M. Numerical Study on Novel Airfoil Fins for Printed Circuit Heat Exchanger Using Supercritical CO2. Int. J. Heat Mass Transf. 2018, 121, 354–366. [Google Scholar] [CrossRef] [Scilit]
- Chang, H.; Han, Z.; Li, X.; Ma, T.; Wang, Q. Experimental Investigation on Heat Transfer Performance Based on Average Thermal-Resistance Ratio for Supercritical Carbon Dioxide in Asymmetric Airfoil-Fin Printed Circuit Heat Exchanger. Energy 2022, 254, 124164. [Google Scholar]
- Zhang, C.; Liu, R.; Wang, Q. Thermal-Hydraulic Performance of Supercritical CO2 in PCHE Channels with the Integration of Airfoil Fins and Vortex-Generating Structures. Int. J. Therm. Sci. 2026, 222, 110578. [Google Scholar]
- Chang, C.-Y.; Chen, W.-H.; Saw, L.H.; Arpia, A.A.; Carrera Uribe, M. Performance Analysis of a Printed Circuit Heat Exchanger with a Novel Mirror-Symmetric Channel Design. Energies 2021, 14, 4252. [Google Scholar] [CrossRef] [Scilit]
- Li, L.; Wu, J.; Yin, J. Geometry Optimization and Performance Prediction of Printed Circuit Heat Exchanger for Supercritical Methane. J. Therm. Sci. 2025, 34, 1953–1963. [Google Scholar] [CrossRef] [Scilit]
- Zheng, C.; Cheng, K.; Han, D. Numerical Investigation of Thermal-Hydraulic Performance of Hitec Molten Salt in Airfoil-Finned Printed Circuit Heat Exchanger. Appl. Therm. Eng. 2026, 297, 130809. [Google Scholar]
- Xu, J.; Cheng, K.; Qin, J.; Wang, C.; Liu, Z.; Liu, X. Structure Effect on Thermal-Hydraulic Performance in Liquid Metal-Aviation Kerosene Printed Circuit Heat Exchanger. Appl. Therm. Eng. 2023, 220, 119741. [Google Scholar]
- Koca, A.; Çalışkan, C.İ.; Koç, E.; Akbal, Ö. A Novel 3D Printed Air-Cooled Fuel Cooler Heat Exchanger for Aviation Industry. Heat Transf. Eng. 2023, 44, 1350–1371. [Google Scholar]
- Thulukkanam, K. Heat Exchanger Design Handbook; CRC Press: Boca Raton, FL, USA, 2013. [Google Scholar]
- Di Bono, G.; Corcione, M.; Quintino, A. Systematic comparative analysis of Kern and Bell-Delaware methods for the design of shell-and-tube heat exchangers. Appl. Therm. Eng. 2025, 278, 127327. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.