Improved Inner-Loop Current Control Strategy Based on Deadbeat Current Prediction

,
,
,
and
1
Pingdingshan Tianan Coal Mining Co., Ltd., Pingdingshan 467000, China
2
Henan Pingmei Shenma Design Institute Co., Ltd., Pingdingshan 467000, China
3
School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454002, China
*
Author to whom correspondence should be addressed.

Abstract

In practical digital control systems for Modular Multilevel Matrix Converters (M3C), the inherent delays caused by signal sampling and algorithm execution lead to pulse output lags in conventional deadbeat control, subsequently resulting in current tracking deviations and grid-side current distortions. To address this issue, an improved deadbeat inner-loop control strategy based on current state prediction is proposed in this paper. First, the mathematical model of the M3C in the abc coordinate system is established, and a dual αβ0 coordinate transformation is introduced to decouple the system, achieving independent control of the input-side, output-side, and internal electrical quantities. Subsequently, to eliminate the control error caused by the one-step delay, an interpolation prediction method is employed to equivalently evaluate the voltage variation within an ultra-short control period. By predicting the current reference state at the k + 2 instant, the deadbeat control equation is modified to achieve delay compensation. Simulation and experimental results demonstrate that the proposed strategy effectively overcomes the delay limitations inherent in conventional digital control, significantly enhancing the dynamic current tracking accuracy and waveform quality of the M3C system.

1. Introduction

The Modular Multilevel Matrix Converter (M3C) has demonstrated significant technical advantages and promising application prospects in fields such as low-frequency AC transmission, offshore wind power grid integration, and high-power AC motor drives [1,2,3]. However, the topology of the M3C is exceptionally complex. It consists of nine arm branches connecting the input and output sides, comprising a large number of sub-module capacitors and exhibiting highly nonlinear, strongly coupled relationships among various electrical quantities [4,5]. To ensure stable and efficient operation under diverse conditions, precise decoupling and multi-dimensional coordinated control of the complex internal circulating currents, common-mode voltages, and AC/DC-side power are imperative [6]. Within the dual-closed-loop control architecture of the M3C, the inner-loop current control serves as the foundation. Its capability to achieve fast and accurate tracking of the reference current directly determines the dynamic response performance, power quality, and anti-interference robustness of the entire system [7].
Among various inner-loop current control strategies, Deadbeat Predictive Control (DBPC) has been widely adopted in power electronic converters due to its notable advantages, including rapid dynamic response and the ability to achieve zero steady-state tracking error within a single control period [8,9]. Nevertheless, in practical digital control systems, inherent physical processes, such as signal sampling, control algorithm execution, and pulse-width modulation (PWM) update, inevitably introduce control delays [10,11]. In an ideal deadbeat control model, the system should instantaneously output the corresponding switching pulse upon the arrival of the k-th control period. In practice, however, constrained by the aforementioned inherent delays, the actual pulse output is frequently postponed to the (k + 1)-th period [12]. This one-step delay phenomenon not only degrades the tracking accuracy and dynamic response of deadbeat control, but also causes distortion in the grid-side current, potentially affecting system stability under severe operating conditions [13].
To mitigate the adverse effects of digital control delays, researchers have proposed various delay compensation and predictive control methods. Conventional single-step delay compensation methods usually predict the future current state to compensate for the one-step digital delay. However, these methods may neglect the real-time variation in the voltage reference within an ultra-short control period, which can reduce the compensation accuracy under low carrier ratios or fast dynamic conditions [14]. Model predictive control and phase-lead compensation strategies have also been introduced to improve dynamic performance. Nevertheless, for M3C systems with nine arms, numerous sub-modules, and strongly coupled multivariable dynamics, the computational burden and parameter dependence of these methods remain important concerns for engineering implementation [12,13,15].
In addition to delay compensation and predictive control, recent studies on modular and cascaded multilevel converters have also emphasized reliability enhancement and fault diagnosis. For example, Lin et al. proposed an improved fault diagnosis method for cascaded H-bridge multilevel converters (CHBMCs) by introducing an E-SVM-based counter design for multiple open-circuit switches [16]. Their work improves the fault diagnosis capability of CHBMCs and highlights the importance of reliability enhancement in modular converter systems. Complementary to these reliability-oriented studies, this paper focuses on improving the current tracking accuracy of M3C systems by compensating for inherent digital control delays.
Consequently, there is an urgent need to develop a computationally efficient deadbeat inner-loop current control strategy tailored to the complex decoupled mathematical model of the M3C. Different from existing PI-based control, conventional deadbeat predictive current control, model predictive control, and standard delay compensation methods, the proposed strategy is developed within a deadbeat current prediction framework. By estimating the voltage variation within an ultra-short control period through interpolation and advancing the current reference state to the (k + 2)-th instant, the proposed method compensates for the one-step digital control delay while improving current tracking accuracy with relatively low computational complexity.
To address the aforementioned issues, this paper proposes an improved inner-loop current control strategy for the M3C based on deadbeat current prediction. This strategy thoroughly analyzes the time-series characteristics of the control delay and achieves precise alignment of control pulses by predicting the system state in advance. The main contributions of this paper are summarized as follows:
  • Based on Kirchhoff’s laws, the mathematical model of the M3C in the abc coordinate system is established, and a dual αβ0 coordinate transformation is employed for decoupling, thereby realizing independent control of the input-side, output-side, circulating current, and common-mode voltage components.
  • To tackle the delay challenge in practical digital control, an interpolation prediction method is utilized to equivalently evaluate the dynamic voltage variations within an ultra-short control period, effectively enhancing the feedforward compensation accuracy of the prediction model.
  • An improved deadbeat control equation for the advance prediction of the current state at the (k + 2)-th instant is derived and formulated. This accomplishes delay compensation at the algorithmic level, ensuring that the control pulses for the k-th period can be generated in advance and applied accurately.
Compared with the conventional deadbeat control scheme, the proposed strategy effectively overcomes the inherent limitation of the one-step lag in digital control systems, reduces the distortion of the grid-side current, and improves the dynamic current tracking precision and overall control quality of the M3C system under complex operating conditions.

2. Topology and Mathematical Model of the M3C

2.1. Topology of the M3C

The topology of the M3C is illustrated in Figure 1. It consists of nine arm branches connecting the input side (A, B, C) and the output side (a, b, c). Each arm is formed by cascading n full-bridge power sub-modules (SMs) and an arm inductor L0.
Figure 1. Topology of the M3C.
As illustrated in Figure 1, based on their connections to the input and output terminals of the M3C, the nine arm branches are denoted by the subscript xy. Here, x represents the input phases A, B, and C, respectively, while y represents the output phases a, b, and c, respectively. The expressions are defined as:
x ∈ {A, B, C}
y ∈ {a, b, c}
Given the identical structure and symmetrical parameters of all arms, the M3C can be viewed as three sub-converters (corresponding to phases a, b, and c) from the perspective of the input-side three-phase system. The variables ux and uy denote the input and output phase voltages, respectively, and ix and iy represent the corresponding phase currents. The arm voltage (defined as the sum of the sub-module capacitor voltages) and the arm current are denoted by uxy and ixy, respectively. The variable ucxyi indicates the capacitor voltage of the i-th sub-module in arm xy. Points O and N represent the neutral points of the input and output three-phase systems, respectively, and uN denotes the common-mode voltage. The reference directions for all electrical quantities are consistent with those indicated in the figure.

2.2. Mathematical Model of M3C

Mathematical Model in the abc Coordinate System

Based on the electrical relationships illustrated in Figure 1, applying Kirchhoff’s Voltage Law (KVL) yields the matrix expression for the mathematical model of the M3C in the abc coordinate system as follows:
u A u B u C u A u B u C u A u B u C = L 0 d d t i A a i B a i C a i A b i B b i C b i A c i B c i C c + u A a u B a u C a u A b u B b u C b u A c u B c u C c + u a u a u a u b u b u b u c u c u c + u N 1 1 1 1 1 1 1 1 1
Similarly, applying Kirchhoff’s Current Law (KCL) yields:
i A = i A a + i A b + i A c i B = i B a + i B b + i B c i C = i C a + i C b + i C c i a = i A a + i B a + i C a i b = i A b + i B b + i C b i c = i A c + i B c + i C c
The arm voltages of the M3C consist of voltages with different frequencies from both terminals of the system, while the arm currents are composed of the input/output-side currents and the internal circulating currents. To establish the mapping relationship between the arm components and the input/output components, a dual αβ0 coordinate transformation is applied to Equation (1) for decoupling, which yields:
3 0 0 0 0 0 0 u s α u s β u s 0 = L 0 d dt i α α i β α i 0 α i α β i β β i 0 β i α 0 i β 0 i 00 +   u α α u β α u 0 α u α β u β β u 0 β u α 0 u β 0 u 00 + 3 0 0 u m α 0 0 u m β 0 0 u m 0 + 3 u N 0 0 0 0 0 0 1 1 1
where usα, usβ, us0 and umα, umβ, um0 denote the input and output voltage components in the αβ0 coordinate system, respectively; iαα, iαβ, iβα, iβ represent the input and output current components in the αβ0 coordinate system, respectively; iαα, iαβ, iβα, iβ and uαα, uαβ, uβα, uββ designate the circulating current components and their corresponding induced voltage components, respectively, which exist exclusively within the system. Given that both the input and output terminals of the M3C are three-phase symmetrical systems with no direct connection between their neutral points, Equation (3) can be further simplified to:
3 0 0 0 0 0 0 u s α u s β 0 = L 0 d dt i α α i β α i 0 α i α β i β β i 0 β i α 0 i β 0 0 +   u α α u β α u 0 α u α β u β β u 0 β u α 0 u β 0 u 00 + 3 0 0 u m α 0 0 u m β 0 0 0 + 3 u N 0 0 0 0 0 0 0 0 1
As indicated by Equation (4), following the dual αβ0 coordinate transformation, the electrical quantities associated with the input side, output side, circulating currents, and common-mode voltages become mutually independent, successfully achieving the decoupling of the M3C. Mapping these corresponding electrical quantities according to their underlying physical meanings yields:
u s α u s β = L 0 3 d d t i α 0 i β 0 + 1 3 u α 0 u β 0
u m α u m β = − 1 3 u 0 α u 0 β − L 0 3 d d t i 0 α i 0 β
L 0 d d t i α α i β α i α β i β β + u α α u β α u α β u β β = 0
u 00 = − 3 u N

3. Improved Inner-Loop Current Control Strategy Based on Deadbeat Current Prediction

3.1. Deadbeat Predictive Control Model

Based on the preceding decoupled model, the input-side current, output-side current, circulating-current, and common-mode voltage components are regulated in their respective control channels. The common-mode voltage component in Equation (8) is not neglected; instead, it is incorporated into the arm-voltage reference through the common-mode control channel. For the inner-loop current controller, the arm-current dynamics of an arbitrary xy-arm are considered. Applying Kirchhoff’s voltage law to the arm connecting input phase x and output phase y yields:
u x y = u x − u y − L 0 d i x y d t
Applying Euler discretization to Equation (9) yields:
u x y ( k ) = u x ( k ) − u y ( k ) − L 0 i x y * ( k + 1 ) − i x y ( k ) T
where uxy(k) and ixy(k) represent the arm voltage and current at the k-th control period, respectively; ux(k) and uy(k) denote the input and output phase voltages at the k-th control period, respectively; and T is the control period.
By setting the arm current at the (k + 1)-th control period, ixy(k + 1), as the reference current  i xy * ( k   +   1 ) , the corresponding term in the above equation can be expressed as:
i x y * ( k + 1 ) = 1 3 i x * ( k + 1 ) + 1 3 i y * ( k + 1 )
where  i x y * denotes the reference arm current, and  i x * and  i y * are the outer-loop current references. The coefficient 1/3 is introduced only for constructing the arm-current reference from the terminal current references, and therefore it is not applied to the measured arm current ixy(k).
Substituting Equations (10) and (11) yields the conventional deadbeat control equation:
u x y * = u x ( k ) − u y ( k ) − L 0 T 1 3 i x * + 1 3 i y * − i x y ( k )
Based on the preceding derivations, the block diagram of the deadbeat predictive control for the M3C is illustrated in Figure 2. In this control scheme, the reference values for the input and output currents, generated by the outer-loop control, are utilized in conjunction with Equation (11) to calculate the arm current reference. Subsequently, the deadbeat control is employed to track the actual current in accordance with Equation (12).
Figure 2. Block diagram of the deadbeat current predictive control.

3.2. Delay Compensation for the Deadbeat Control

In the theoretical control process described above, the signal sampling, computation, and pulse output of the controller are assumed to occur synchronously. In practical digital implementations, however, both the sampling operations and the execution of the control algorithm inherently introduce certain time delays. Consequently, the sampling instant typically precedes the pulse output instant, and this time delay is denoted as td. The presence of td induces control errors, rendering the deadbeat control incapable of precisely tracking the real-time dynamic variations in the current. This tracking deviation ultimately results in distortion of the grid-side current, the underlying mechanism of which is illustrated in Figure 3.
Figure 3. Schematic diagram of the control delay.
An in-depth analysis of the time-series characteristics of the control delay reveals that, under ideal conditions, the corresponding pulse signal should instantaneously transition to the pulse pattern required for the k-th period upon its arrival. In practice, however, the generation of pulses necessitates processing through both the control and modulation stages, which inherently introduces a time delay. Typically, the pulse output lags by a duration of td. Consequently, even when the k-th control period commences, the actual output pulse remains in the state of the preceding (k − 1)-th period. This phenomenon introduces a significant lag into the control process, thereby adversely affecting the overall control performance.
To mitigate the adverse influence of the one-step digital delay, an improved deadbeat current prediction strategy is proposed. In this strategy, the arm-current reference is advanced to the (k + 2)-th instant, so that the voltage reference required for the digital implementation with one-step delay can be generated in advance.
Based on the deadbeat current prediction model in Equation (10), the improved arm-voltage reference of an arbitrary xy-arm can be expressed as:
u x y r e f = u x ( k + 1 ) − u y ( k + 1 ) − L 0 T i x y * ( k + 2 ) − i x y ( k + 1 )
where uxyref denotes the arm-voltage reference generated by the improved deadbeat control strategy, and  i xy * ( k   +   2 ) is the advanced arm-current reference at the (k + 2)-th instant.
To achieve precise predictions of ux(k + 1) and uy(k + 1), an interpolation-based prediction method is employed. Considering the extremely short control period of the system, it is reasonable to assume that the variations in ux and uy during the (k − 1)-th period are approximately equal to those during the k-th period, which can be expressed as:
u x ( k + 1 ) − u x ( k ) = u x ( k ) − u x ( k − 1 ) u y ( k + 1 ) − u y ( k ) = u y ( k ) − u y ( k − 1 )
The predicted values of ux(k + 1) and uy(k + 1) are obtained as:
u x ( k + 1 ) = 2 u x ( k ) − u x ( k − 1 ) u y ( k + 1 ) = 2 u y ( k ) − u y ( k − 1 )
Using Equation (15) to predict ux(k + 1) and uy(k + 1), and using the discretized arm-current model to predict ixy(k + 1), Equation (13) can be rearranged to obtain the improved deadbeat control equation, as expressed in Equation (16). The corrected arm-current reference relationship in Equation (11) is consistently used in this derivation.
u x y r e f = 3 u x ( k ) − 3 u y ( k ) − u x ( k − 1 ) + u y ( k − 1 ) − L 0 T [ i x y r e f − i x y ( k ) ] − u x y ( k ) = u x ( k ) − u y ( k ) − L 0 T [ i x y r e f − i x y ( k ) ] + [ u x ( k ) − u y ( k ) − u x y ( k ) ] + [ u x ( k ) − u x ( k − 1 ) ] + [ u y ( k − 1 ) − u y ( k ) ]
Based on the aforementioned derivations, the block diagram of the improved deadbeat control strategy is illustrated in Figure 4.
Figure 4. Block diagram of the improved deadbeat control strategy.

3.3. Computational Complexity Analysis

A major challenge in applying digital control to M3C systems is the computational delay. To quantitatively illustrate the efficiency of the proposed deadbeat approach, a complexity comparison with the conventional Finite Control Set Model Predictive Control (FCS-MPC) is presented in Table 1.
Table 1. Complexity comparison between the proposed method and FCS-MPC.
FCS-MPC inherently relies on a rolling optimization framework. Even when adopting a reduced virtual voltage vector set to mitigate the curse of dimensionality, the controller must iteratively evaluate the cost function for at least 27 vector combinations during each sampling period. This iterative nature leads to a computational complexity of O(N), where N is the number of admissible vectors, inevitably occupying significant DSP execution time.
Conversely, the proposed deadbeat strategy circumvents this iterative burden. It mathematically derives the required reference voltages via direct analytical equations, necessitating only a single evaluation per cycle. This achieves an optimal O(1) complexity and completely eliminates the need for empirical weighting factor design. By fundamentally minimizing the algorithmic execution time, the proposed method effectively suppresses the delay-induced phase lag, thereby ensuring superior dynamic tracking performance.

4. Simulation and Experimental Verification

4.1. Simulation Results and Analysis

To verify the effectiveness of the proposed improved deadbeat inner-loop current control strategy, a simulation model of the M3C system is developed on the MATLAB/Simulink (2024b) platform. The key simulation parameters are summarized in Table 2.
Table 2. Simulation parameters of the M3C system.

4.1.1. Steady-State Simulation Analysis

Figure 5 and Figure 6 present the comparative simulation results of the M3C inner-loop control under different strategies. Specifically, Figure 5a illustrates the tracking waveform of the A-a arm current iAa under the conventional PI-based inner-loop control, while Figure 5b shows the corresponding result obtained with the proposed improved inner-loop control. It can be observed that the conventional control exhibits slight tracking deviations at some critical points of the A-a arm current. In contrast, the actual current obtained with the proposed algorithm closely follows the reference current command  i A a * , indicating improved steady-state current tracking accuracy.
Figure 5. Comparative tracking performance of the A-a arm current iAa under steady-state conditions.
Figure 6. Comparison of arm current tracking errors.
To provide a more detailed evaluation, Figure 6a,b depict the tracking errors for the three arm currents within sub-converter a under both strategies. The results indicate that the conventional algorithm suffers from significant prediction errors, with a peak value approaching 150 A. However, the proposed predictive algorithm significantly suppresses these errors, reducing the maximum deviation to approximately 80 A. Consequently, the improved predictive strategy demonstrates superior tracking accuracy and enhanced system stability.

4.1.2. Transient-State Simulation Analysis

To further demonstrate the dynamic performance of the proposed control strategy in terms of response speed and smoothness, comparative simulations are conducted under transient operating conditions. At t = 0.8 s, the transmitted power of the system is stepped down by 50%. The resulting dynamic response waveforms are shown in Figure 7. Figure 7 illustrates the tracking performance of the A-a arm current iAa during this transient event. Compared with the conventional control method, the proposed strategy reduces the transient tracking deviation and improves the dynamic current response during the power step-down process.
Figure 7. Dynamic tracking performance of the A-a arm current iAa under transient operating conditions.

4.1.3. Comparative Analysis Under Different Control Strategies

To further demonstrate the effectiveness and specific contribution of the proposed improved deadbeat current control strategy, four control schemes were comparatively investigated, namely conventional PI control, conventional deadbeat predictive current control without delay compensation, deadbeat predictive current control with standard one-step delay compensation, and the proposed interpolation-based improved deadbeat predictive current control. For a fair comparison, the same M3C circuit parameters and operating conditions were adopted for all schemes. The A-a arm current tracking error was used as the main evaluation index and is defined as  e A a = i A a * − i A a , where  i A a * represents the reference A-a arm current and iAa represents the actual A-a arm current.
Figure 8 shows the steady-state tracking waveforms of the A-a arm current iAa under different control strategies. It can be observed that the conventional PI control and conventional DBPC exhibit visible deviations between the reference current  i A a * and the actual current iAa. The standard one-step delay compensation DBPC improves the tracking performance by compensating for the digital control delay. In comparison, the proposed method achieves the closest agreement between the reference and actual currents, indicating improved steady-state tracking accuracy.
Figure 8. Steady-state comparison of A-a arm current tracking waveforms under different control strategies.
Figure 9 further compares the steady-state tracking error eAa under different control strategies. The conventional PI control and conventional DBPC produce relatively large periodic tracking errors. The standard one-step delay compensation DBPC reduces the error amplitude to a certain extent. However, residual tracking error still exists because the voltage variation within the control period is not fully considered. The proposed method obtains a smaller and more stable tracking error, which verifies the effectiveness of the interpolation-based voltage variation estimation in improving the steady-state compensation accuracy.
Figure 9. Steady-state comparison of A-a arm current tracking errors under different control strategies.
Figure 10 presents the transient tracking waveforms of the A-a arm current iAa when the transmitted power is stepped down by 50% at t = 0.8 s. During the transient process, the conventional PI control and conventional DBPC show larger deviations between  i A a * and iAa. The one-step delay compensation DBPC improves the current tracking performance, while the proposed method provides smoother tracking and better agreement between the reference and actual currents.
Figure 10. Transient comparison of A-a arm current tracking waveforms under different control strategies during the power step-down condition.
Figure 11 presents the transient tracking error comparison when the transmitted power is stepped down by 50% at t = 0.8 s. During the transient process, the conventional PI control and conventional DBPC produce larger tracking errors. The standard one-step delay compensation DBPC improves the transient tracking performance, but its error fluctuation is still higher than that of the proposed method. The proposed method maintains a smaller bounded error during the power step-down process, demonstrating better dynamic tracking capability and delay compensation performance.
Figure 11. Transient comparison of A-a arm current tracking errors under different control strategies during the power step-down condition.
The quantitative comparison is summarized in Table 3. Compared with conventional PI control and conventional DBPC, the proposed method effectively reduces the maximum tracking error, RMSE, MAE, and peak-to-peak error under both steady-state and transient operating conditions. Although the standard one-step delay compensation DBPC improves the tracking performance compared with conventional DBPC, the proposed method further reduces the residual tracking error by considering the voltage variation within the control period. These results demonstrate that the proposed method provides an additional improvement over conventional deadbeat predictive control, thereby confirming the specific contribution of the proposed strategy.
Table 3. Quantitative comparison of A-a arm current tracking errors under different control strategies.

4.1.4. Robustness Verification Against Parameter Mismatches

Although the interpolation-based voltage prediction is reasonable within an ultra-short control period, the accuracy of deadbeat predictive current control may still be affected by parameter mismatches in practical digital implementations. In actual M3C systems, the arm inductance and sub-module capacitance may deviate from their nominal values due to manufacturing tolerances, temperature variations, aging effects, and modeling uncertainties. Therefore, additional simulations were carried out to evaluate the robustness of the proposed control strategy against parameter mismatches.
In the robustness verification, the actual plant parameters and the controller prediction parameters were separated to emulate practical parameter deviations. The arm inductance L0 and the sub-module capacitance C0 were selected as the main mismatch parameters. Six cases were considered, including the nominal case, L0 − 20%, L0 + 20%, C0 − 20%, C0 + 20%, and the combined mismatch condition of L0 +20% and C0 − 20%. The current tracking error of the A-a arm, denoted as eAa, was selected as the evaluation index, which is defined as the difference between the reference arm current and the actual arm current.
Figure 12 shows the current tracking performance of the proposed control strategy under representative parameter mismatch conditions. It can be observed that the actual current can still closely follow the reference current under the L0 − 20%, L0 + 20%, and combined L0 + 20%, C0 − 20% conditions. Although slight tracking deviations appear near some dynamic variation intervals, no divergence or severe oscillation occurs. This demonstrates that the proposed strategy can maintain stable current tracking capability under representative inductance and combined parameter mismatch conditions.
Figure 12. Current tracking performance of the proposed control strategy under representative parameter mismatch conditions.
To further compare the influence of different parameter mismatches on the tracking accuracy, Figure 13 presents the current tracking error eAa under all tested mismatch cases. The error curves remain bounded under all parameter deviations, indicating that the proposed interpolation-based deadbeat current prediction method does not lose stability when moderate parameter mismatches are introduced. Although slight error variations can be observed under different mismatch conditions, the tracking error remains bounded, and no unstable oscillation occurs.
Figure 13. Current tracking error under different parameter mismatch conditions.
The quantitative comparison is summarized in Table 4. Compared with the nominal case, the most evident performance degradation occurs when the arm inductance decreases by 20%, where the maximum tracking error increases from 113.18 A to 127.31 A, and the RMSE increases from 41.52 A to 48.25 A. For the other mismatch cases, the tracking indices vary within a limited range. In particular, the capacitance mismatch cases do not lead to significant deterioration of the current tracking performance. These results verify that the proposed control strategy exhibits satisfactory robustness against moderate mismatches of the arm inductance and sub-module capacitance.
Table 4. Quantitative comparison of current tracking performance under parameter mismatches.

4.2. Experimental Verification

To verify the feasibility of the control strategy proposed in this paper, an M3C experimental platform based on DSP + FPGA as the main controller was built.
The specific parameters of the experimental platform are detailed in Table 5.
Table 5. Experimental parameters of the M3C system.
Figure 14 shows the experimental results of the M3C under steady-state operating conditions. It can be seen from the output waveforms that the input and output current and voltage waveforms meet the requirements of the M3C output characteristics; the arm currents between sub-converter a and different sub-converters contain two frequency components and run stably.
Figure 14. Experimental waveforms of the M3C under steady-state operation.
To further validate the practical effectiveness of the proposed control strategy, experimental comparisons were conducted under the same operating conditions using four control schemes: conventional PI control, conventional deadbeat predictive current control without delay compensation, deadbeat predictive current control with standard one-step delay compensation, and the proposed interpolation-based improved deadbeat predictive current control. The A-a arm current tracking error eAa was selected as the evaluation variable to compare the current tracking performance of different methods.
Figure 15 shows the experimental steady-state comparison of the A-a arm current tracking error eAa under different control strategies. It can be observed that the conventional PI control and conventional DBPC exhibit relatively larger periodic tracking errors. The standard one-step delay compensation DBPC reduces the error amplitude to a certain extent by compensating for the digital control delay. In comparison, the proposed method maintains a smaller bounded tracking error, indicating improved steady-state current tracking accuracy in practical implementation.
Figure 15. Experimental steady-state comparison of A-a arm current tracking errors under different control strategies.
Figure 16 presents the experimental transient comparison of the A-a arm current tracking error eAa under different control strategies. During the transient process, the conventional PI control and conventional DBPC generate larger error fluctuations, while the one-step delay compensation DBPC improves the tracking performance to some extent. Compared with these methods, the proposed method maintains a smaller tracking error and smoother error variation, demonstrating better dynamic tracking capability and practical delay compensation performance.
Figure 16. Experimental transient comparison of A-a arm current tracking errors under different control strategies.
In summary, the simulation and experimental results presented in Figure 5, Figure 6, Figure 7, Figure 8, Figure 9, Figure 10, Figure 11, Figure 12, Figure 13, Figure 14 and Figure 15 validate the effectiveness and practical feasibility of the proposed control strategy. Figure 5, Figure 6 and Figure 7 show that the proposed method achieves better A-a arm current iAa tracking performance than the conventional PI-based control under both steady-state and transient conditions. The comparative results in Figure 8, Figure 9, Figure 10 and Figure 11 and Table 3 further demonstrate that, compared with conventional DBPC and standard one-step delay compensation DBPC, the proposed method can further reduce the current tracking error by considering the voltage variation within the control period.
In addition, the robustness results in Figure 12 and Figure 13 indicate that the proposed method maintains stable current tracking performance under representative parameter mismatch conditions. The experimental results in Figure 14 and Figure 15 further confirm that the proposed strategy can be effectively implemented in practice. These results consistently support the theoretical analysis and verify that the proposed method improves current tracking accuracy, compensates for inherent digital control delay, and enhances the dynamic performance of the M3C system.

5. Conclusions

To address the issues of tracking misalignment and grid-side current distortion caused by inherent delays in the digital control system of the Modular Multilevel Matrix Converter (M3C), this paper proposes an improved inner-loop current control strategy based on deadbeat current prediction. By introducing the dual αβ0 coordinate transformation, complete independent decoupling of the multi-dimensional, strongly coupled electrical quantities within the M3C is achieved. Meanwhile, an interpolation-based prediction method is utilized to equivalently evaluate the dynamic voltage variations. By advancing the current reference state to the (k + 2)-th instant and modifying the deadbeat control equations, fundamental compensation for the inherent control delay is effectively realized. Simulation and experimental results demonstrate that, under steady-state conditions, the proposed method effectively eliminates the control errors induced by pulse output lag, achieving accurate tracking of the reference commands. Under transient operating conditions, the improved strategy effectively suppresses transient current fluctuations and overshoots compared with the conventional deadbeat control. Furthermore, robustness simulations considering arm inductance and sub-module capacitance mismatches show that the proposed method maintains stable current tracking performance under ±20% parameter deviations, further demonstrating its practical applicability and robustness in digital control implementations.

Author Contributions

Conceptualization, X.Z.; methodology, X.Z.; software, X.Z.; validation, X.Z., L.P. and Q.W.; formal analysis, X.Z.; investigation, X.Z.; resources, J.J. and X.M.; data curation, X.Z.; writing—original draft preparation, X.Z.; writing—review and editing, X.Z., L.P., J.J., Q.W. and X.M.; visualization, X.Z.; supervision, J.J. and X.M.; project administration, X.Z.; funding acquisition, X.Z. and J.J. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Science and Technology Department of Henan Province, grant number 252102241041.

Data Availability Statement

The data that support the findings of this study are available from the Corresponding author, Xiaoniu Zhang, upon reasonable request.

Conflicts of Interest

Authors Xiaoniu Zhang and Junwei Jing were employed by the company Pingdingshan Tianan Coal Mining Co., Ltd. Authors Lixin Pang and Qingchi Wei were employed by the company Henan Pingmei Shenma Design Institute Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. Himker, R.; Mertens, A. Operating-point-optimized control strategy for modular multilevel converters in low-frequency AC transmission systems. IEEE Trans. Power Electron. 2023, 39, 2334–2350. [Google Scholar] [CrossRef] [Scilit]
  2. Utvić, M.; Bontemps, P.; Dujić, D. Direct arm energy control of the modular multilevel matrix converter. IEEE Access 2023, 11, 1793–1805. [Google Scholar] [CrossRef] [Scilit]
  3. Urrutia Ortiz, M.A. Control of the Modular Multilevel Matrix Converter Based on Continuous Control Set Model Predictive Control; University of Oviedo: Oviedo, Spain, 2022. [Google Scholar]
  4. Liu, S.; Zhao, B.; Wang, G.; Wang, X. An improved phasor method for modelling and analysis of modular multilevel matrix converter. IEEE Trans. Power Deliv. 2020, 36, 1744–1755. [Google Scholar] [CrossRef] [Scilit]
  5. Ni, X.; Qiu, P.; Lin, J.; Lu, Y.; Jin, Y.; Xu, H. Selection Methods of Main Circuit Parameters for Modular Multilevel Matrix Converters. In Proceedings of the 2021 International Conference on Power System Technology (POWERCON); IEEE: Piscataway, NJ, USA, 2021; pp. 1304–1309. [Google Scholar]
  6. Bontemps, P.; Milovanovic, S.; Dujic, D. Performance analysis of energy balancing methods for matrix modular multilevel converters. IEEE Trans. Power Electron. 2022, 38, 2910–2924. [Google Scholar] [CrossRef] [Scilit]
  7. Wang, R.; Yu, Y.; Yang, J.; Wang, F.; Wang, X. Fuzzy Improved Linear Active Disturbance Rejection Control Strategy for Modular Multilevel Matrix Converter Under Unbalanced Power Grid. J. Electr. Eng. Technol. 2026, 1–19. [Google Scholar] [CrossRef] [Scilit]
  8. Wang, R.; Zhang, S.; Yang, Y.; Wen, Y.; Sun, X.; Zhou, Z.; Li, Y. Overview of Deadbeat Predictive Control Technology for Permanent Magnet Synchronous Motor System. Energies 2025, 18, 4668. [Google Scholar] [CrossRef] [Scilit]
  9. Jiang, X.; Qin, H.; Zhao, Z.; Li, F.; Li, Z.; Ling, Z. Deadbeat Predictive Current Control with High Accuracy Under a Low Sampling Ratio for Permanent Magnet Synchronous Machines in Flywheel Energy Storage Systems. Machines 2025, 13, 995. [Google Scholar] [CrossRef] [Scilit]
  10. Li, J.; Ma, X.; Wu, B.; Li, R.; Yang, R. Robust control delay compensation method for grid connected inverter based on improved Newton interpolation. CSEE J. Power Energy Syst. 2022, 11, 783–792. [Google Scholar]
  11. Lee, S. Improvement of Stability of a Grid-Connected Inverter with an LCL filter by Robust Strong Active Damping and Model Predictive Control. Master’s Thesis, University of Arkansas, Fayetteville, AR, USA, 2021. [Google Scholar]
  12. Mora, A.; Espinoza, M.; Diaz, M.; Cardenas, R. Model predictive control of modular multilevel matrix converter. In Proceedings of the 2015 IEEE 24th International Symposium on Industrial Electronics (ISIE); IEEE: Piscataway, NJ, USA, 2015; pp. 1074–1079. [Google Scholar]
  13. Rodriguez, J.; Kazmierkowski, M.P.; Espinoza, J.R.; Zanchetta, P.; Abu-Rub, H.; Young, H.A.; Rojas, C.A. State of the art of finite control set model predictive control in power electronics. IEEE Trans. Ind. Inform. 2012, 9, 1003–1016. [Google Scholar] [CrossRef] [Scilit]
  14. Wang, H.; Gan, C.; Ren, H.; Zhang, C.; Shan, X.; Qu, R. An input-delay compensation strategy for deadbeat predictive current control of PMSM. IEEE Trans. Ind. Electron. 2025, 72, 11141–11146. [Google Scholar] [CrossRef] [Scilit]
  15. Elhassan, G.; Zulkifli, S.A.; Pathan, E.; Khan, M.H.; Jackson, R. A comprehensive review on time-delay compensation techniques for grid-connected inverters. IET Renew. Power Gener. 2021, 15, 251–266. [Google Scholar] [CrossRef] [Scilit]
  16. Lin, H.; Chung, H.S.-H.; Lin, C.; Xie, D.; Deng, Q.; Lyu, M.; Goetz, S.M.; Chen, J.; Ge, X. Improved Fault Diagnosis Capability in CHBMCs: Counter Design for Multiple OC Switches Via an E-SVM Unit. IEEE Trans. Power Electron. 2025, 41, 2358–2376. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.