Skip to Content
  • News
  • Open Access

31 December 2002

Menarini Prize for Echocardiography

Münchensteinerstrasse 117, 4053 Basel, Switzerland
An der Jahrestagung der Schweizerischen Gesellschaft für Kardiologie vom Juni 2002 in Bern wurden von der Arbeitsgruppe Echokardiographie erstmals drei von der Firma Menarini Schweiz AG gestifteten Preise für die besten Präsentationen über Echokardiographie ausgeschrieben. Die drei Preisträger wurden von einer 6köpfigen Jury, bestehend aus Vertretern der Universitätsspitäler, nicht universitären Spitäler und der praktizierenden Kardiologen, evaluiert.

Erster Preis

Der erste Preis (dotiert mit 1000.— Fr.) ging an:
Markus Schwerzmann, Michael Billinger, Sandra Gerber, Rolf Vogel, Bernhard Meier, Stephan Windecker, Christian Seiler (Swiss Cardiovascular Center, Bern, Cardiology, University Hospital, Bern, Switzerland) für die Arbeit:
Optimization of Contrast Transesophageal Echocardiography for the Detection of Patent Foramen Ovale in Divers
In stroke patients, transesophageal echocardiography (TEE) with cubital vein contrast delivery has been regarded to have the best sensitivity for detecting a patent foramen ovale (PFO): Due to anatomical reasons (valvula Eustachii), administration of contrast via the vena cava inferior (VCI) into the right atrium may, however, enhance TEE sensitivity for detecting a PFO. To test this hypothesis, we attempted to puncture the cubital vein and a peripheral leg vein in 79 divers undergoing TEE. Puncture of a peripheral vein could be performed in 2/3 of all divers. For the detection of a PFO, 5 ml aerated colloid solution followed by flushing with 10 ml saline, was injected. In 11 of 52 divers (21%) right-to-left shunting following release of the Valsalva maneuver was demonstrated after cubital contrast administration. After injection of contrast into the leg vein, a PFO was diagnosed in 2 additional divers (13 of 52). Assuming peripheral leg vein administration of contrast as the "gold standard" for PFO detection, cubital contrast injection had a sensitivity of only 85%. As hypothesized, detection of a PFO by TEE can be improved by contrast injection into a peripheral leg vein.

Zweiter Preis

Der zweite Preis (dotiert mit 500.— Fr.) ging an:
Richard Kobzal , Erwin Oechslinl , David J. Kurzl, René Prétre2, Michel Zuber3, Peter Vogt4, Rolf Jennil (1 Cardiology, 2 Cardiovascular Surgery and 4 Pathology, University Hospital Zurich and 3 Cardiology, Kantonsspital Lucerne, Switzerland) für die Arbeit:
Aberrant Tendinous Chords with Tethering of the Tricuspid Leaflets: Congenital Anomaly Causing Severe Tricuspid Regurgitation
Tethering was defined by the presence of aberrant tendinous chords to one or more tricuspid valve leaflets. We defined aberrant tendinous chords as those inserting at the clear zone of the tricuspid leaflet and originating from the endocardium. Tethering results in incomplete coaptation of the tricuspid leaflets and a more apical origin of the regurgitant jet than seen in other etiologies of tricuspid regurgitation. The last 13 500 consecutive echocardiographic studies from our facility were reviewed to identify patients with severe, unexplained tricuspid regurgitation. Ten patients with aberrant tendinous chords tethering one or more tricuspid valve leaflets were identified. Tethering was the only mechanism of tricuspid regurgitation in three patients, whereas it was associated with short primary tendinous chords in seven patients. Six patients had associated congenital heart disease. Tethering of the tricuspid valve leaflets due to aberrant tendinous chords is a distinct and previously unrecognized cause of congenital tricuspid regurgitation. One or more of all three tricuspid valve leaflets may be affected.

Dritter Preis

Der dritte Preis (dotiert mit 300.— Fr.) ging an:
D. Tüller, M. Steiner, M. Kabok, C. Seiler (Swiss Cardiovascular Center, Bern, Cardiology, University Hospital, Bern, Switzerland) für die Arbeit:
Beurteilung der systolischen rechtsventrikulären Funktion mittels Gewebsdoppleruntersuchung des lateralen Trikuspidalannulus
Die quantitative echokardiographische Erfassung der systolischen rechtsventrikulären Funktion (RVEF) bietet aufgrund der komplexen Geometrie und der eingeschränkten Einsehbarkeit des RV immer noch Probleme. Wir untersuchten, ob die mittels Gewebsdoppler gemessene maximale Geschwindigkeit, mit der sich der laterale Trikuspidalannulus gegen den Apex bewegt, mit der RVEF korreliert. 225 Patienten wurden echokardiographisch untersucht: 59 mit eingeschränkter RVEF; 95 Normale; 71 mit eingeschränkter linksventrikulärer systolischer Funktion oder pulmonalarterieller Hypertonie. Als Referenzwert für die RVEF wurde das Mittel aus drei volumetrischen echokardiographischen Bestimmungsmethoden gewählt. Die Patienten mit einer eingeschränkten RVEF wiesen eine signifikant tiefere maximale systolische Geschwindigkeit des lateralen Trikuspidalannulus auf. Eine Geschwindigkeit von 12,5 cm/s unterschied eine normale von einer eingeschränkten RVEF mit einer Sensitivitiit von 85% und einer Spezifitiit von 80%.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.