A Wide-Complex Tachycardia in a 90-Year Old Man with a Dual-Chamber Pacemaker
Excerpt
A 90-year-old man with ischaemic heart disease with preserved ejection fraction, paroxysmal atrial flutter and sinus sick syndrome requiring dual-chamber pacemaker implantation 2 years earlier (Sorin KORA 250 DR, atrial lead VEGA R52, ventricular lead VEGA R58; stimulation mode AAIR-DDDR, lower rate limit 60 beats/min, maximum tracking rate 130 beats/min), was brought to the emergency department because of ongoing palpitations for the past 10 days [...]
Share and Cite
Vellaa, A.; Sutera, P.; Grafb, D.; Vivekananthamb, H. A Wide-Complex Tachycardia in a 90-Year Old Man with a Dual-Chamber Pacemaker. Cardiovasc. Med. 2022, 25, 56. https://doi.org/10.4414/cvm.2022.02192
Vellaa A, Sutera P, Grafb D, Vivekananthamb H. A Wide-Complex Tachycardia in a 90-Year Old Man with a Dual-Chamber Pacemaker. Cardiovascular Medicine. 2022; 25(1):56. https://doi.org/10.4414/cvm.2022.02192
Chicago/Turabian StyleVellaa, Agnese, Philipp Sutera, Denis Grafb, and Hari Vivekananthamb. 2022. "A Wide-Complex Tachycardia in a 90-Year Old Man with a Dual-Chamber Pacemaker" Cardiovascular Medicine 25, no. 1: 56. https://doi.org/10.4414/cvm.2022.02192
APA StyleVellaa, A., Sutera, P., Grafb, D., & Vivekananthamb, H. (2022). A Wide-Complex Tachycardia in a 90-Year Old Man with a Dual-Chamber Pacemaker. Cardiovascular Medicine, 25(1), 56. https://doi.org/10.4414/cvm.2022.02192