Abstract
Background and Objectives: We assessed the diagnostic performance of artificial intelligence (AI) for identifying soft-tissue calcifications on dental images. Materials and Methods: PubMed, Scopus and Web of Science were searched on 1 May 2026. English-language reports of trained AI systems published by that date were eligible without a lower publication-date limit. Registration was retrospective (INPLASY202660038). Extracted data were checked against primary sources, and risk of bias was assessed using QUADAS-2. An exploratory meta-analysis separately pooled sensitivity and specificity from three classifiers of prepared panoramic cervical regions of interest (ROIs), using logit random-effects models, restricted maximum likelihood and modified Knapp–Hartung intervals. Results: Twenty reports were included: 15 using panoramic radiography and five using cone-beam computed tomography (CBCT). The restricted meta-analysis comprised 347 test ROIs or sides, with 133 reference-positive and 214 reference-negative regions. These were not 347 independent patients. Summary sensitivity was 0.9376 (95% CI 0.5314–0.9950) and specificity was 0.9424 (0.5286–0.9958). The intervals assumed regional independence and did not incorporate an empirical correction for patient-level clustering. Alternative-model, threshold, cohort-omission and assumed variance-inflation analyses were examined. Other outcomes differed in target, task, unit or available denominators and remained descriptive. Conclusions: AI showed promising classification performance in selected radiographic datasets. The small exploratory synthesis was imprecise and does not establish patient-level screening accuracy, clinically verified disease detection or equivalence between panoramic radiography and CBCT.
1. Introduction
Soft-tissue calcifications are often found incidentally on dental radiographs. They include carotid artery calcifications, sialoliths, tonsilloliths, calcified lymph nodes and phleboliths [1]. Carotid artery calcifications are of particular interest because their presence may be associated with vascular disease and subsequent vascular events [2,3,4]. Identifying a radiographic calcification, however, does not establish the presence or severity of carotid stenosis. Its interpretation and any referral decision require the patient’s clinical context.
Recognition of carotid calcification on panoramic images can be complicated by other radiopacities in the same region, including calcified thyroid or triticeous cartilage [1,3]. Cone-beam computed tomography (CBCT) also reveals incidental calcifications, but its three-dimensional images and anatomical coverage differ from panoramic radiography [5,6]. These differences affect which findings are visible and how they can be evaluated.
Artificial intelligence (AI) is increasingly used in dental image analysis, including classification, lesion detection and segmentation [7,8]. These tasks answer different questions: a classifier assigns a label to an image or region, a detector locates a finding, and a segmentation model delineates its extent. Their performance measures are consequently not interchangeable. Accuracy against expert image annotations also differs from accuracy against a clinical disease reference standard.
This systematic review assessed the reported performance of trained AI systems for identifying soft-tissue calcifications on dental images. We described the evidence by target, modality and evaluation task, and undertook an exploratory meta-analysis only where the available counts and evaluation units supported a coherent diagnostic question.
2. Materials and Methods
This review was registered retrospectively in INPLASY on 7 June 2026 (INPLASY202660038). The registration records the review as completed but not published; it therefore followed screening and extraction [9]. Reporting follows PRISMA 2020 [10]. During revision, we clarified eligibility and outcome definitions, verified the extracted data against primary sources, and replaced the original synthesis of mixed evaluation units with a restricted exploratory meta-analysis. We also withdrew an indirect modality comparison and the lower publication-date restriction introduced on 13 November 2026. These changes were made during revision and were not prospectively registered. The review question was: What performance has been reported for AI identification of radiographically visible soft-tissue calcifications on dental images, compared with the reference standard used in each study? The PICO elements were as follows:
- P (population) = People undergoing dental panoramic radiography or CBCT, including studies with enriched image datasets.
- I (index test) = Trained machine-learning or deep-learning systems for classification, detection, or segmentation of soft-tissue calcifications.
- C (reference standard) = Expert image annotations or diagnoses corroborated by other imaging or clinical methods, recorded separately for each study.
- O (outcomes) = Sensitivity or recall, specificity, precision or positive predictive value, F1-score, and spatial-overlap measures, retained within their reported task and evaluation unit.
2.1. Eligibility Criteria
Original English-language reports published on or before 1 May 2026 were eligible if they evaluated a trained AI system for identifying soft-tissue calcifications on human dental images. There was no lower publication-date limit. We used the earliest publication date, including online publication before the journal issue date. Eligible methods included trained support-vector machines and neural networks, as well as deep-learning classifiers, detectors and segmentation models. Fixed image filters or rule-based preprocessing alone did not qualify, but such steps did not exclude a study when they formed part of a trained classifier. Studies of several abnormalities were eligible when results for a relevant calcification target could be extracted separately. Reviews, case reports, in vitro investigations and technical descriptions without an original diagnostic evaluation were excluded. Original short reports and conference papers were judged by their methods and outcomes rather than publication format alone.
The registered criteria did not specify a publication-year cutoff or restrict eligibility to deep learning [9]. We withdrew the lower date boundary introduced on 13 November 2026 because publication year did not provide a scientific basis for excluding earlier trained machine-learning methods. Sawagashira 2011, Sawagashira 2013 and Harada 2013 were consequently included in the narrative synthesis and QUADAS-2 assessment [11,12,13]. Their support-vector-machine pipelines met the revised criteria despite incorporating fixed preprocessing steps. The two Sawagashira publications describe related datasets and were not treated as independent cohorts. Their lesion-detection outcomes and false positives per image were incompatible with the restricted ROI-classification meta-analysis. The report-level reconciliation is provided in Supplementary Material S3.
2.2. Search Strategy
PubMed, Scopus and Web of Science were searched on 1 May 2026. Table 1 reproduces the strategies reported for those searches without retrospectively adding terms. During the November 2026 revision, targeted verification of known reports included Lee and the earlier Sawagashira and Harada publications [11,12,13,14]. This was source verification rather than a repeat of the three database searches. The original strategies did not explicitly include support-vector-machine, SVM or computer-aided-detection terms, so some eligible classical machine-learning reports may have been missed. The reported strings, dates and yields, together with the limits of the retained search documentation, are described in Supplementary Material S5 [15]. The publication-eligibility endpoint remained 1 May 2026.
Table 1.
Strategies reported for the database searches on 1 May 2026.
2.3. Study Selection
Records were imported into Rayyan for duplicate removal and screening. Two reviewers (H.A.A. and A.A.) independently screened titles and abstracts and then assessed potentially eligible full texts. Disagreements were resolved by discussion, with a third reviewer consulted when necessary. Supplementary Material S3 distinguishes the original database-selection pathway from the additional report assessed during revision. The extraction verification and risk-of-bias procedures are described separately below.
2.4. Data Extraction
During revision, extracted values were checked against the primary reports for each study, model or system, target condition, threshold, evaluation task and unit. This verification was not an independent duplicate extraction. The extraction records include reported metrics; verified true-positive, false-positive, false-negative and true-negative counts; metric-specific denominators; development and evaluation samples; lesion-matching rules; averaging methods; clustering and patient-level separation; reference standards; and supporting source locations. Total dataset size was not substituted for an outcome-specific denominator, and counts were not reconstructed from rounded metrics.
Supplementary Dataset S1 contains 78 model and outcome records from 20 reports. Three outcome records from the two Sawagashira reports and one learned-model configuration from Harada were included following the eligibility amendment. Results from different models, classes, thresholds or evaluation units were kept separate. Patient-level projections were distinguished from observed test results, and multiple models from one study were not counted as independent studies. Discrepancies within a source were recorded without replacing the reported values. Table 2 summarises report characteristics and performance definitions; Supplementary Material S1 documents acquisition and reference-standard methods.
Table 2.
Report characteristics, evaluation units and performance definitions for the 20 included report entries. Kuwada et al. [16] and Mitsuya et al. [17] form a potentially overlapping cohort family and never enter a pooled analysis together. The two reports by Sawagashira et al. [11,12] are linked reports from an expanded dataset and are not independent cohorts. Metric values are source-reported unless a calculation is explicitly identified.
ChatGPT (OpenAI; GPT-6 Astra Pro for the final revision) assisted with primary-source cross-checking, preparation of extraction and QUADAS-2 worksheets, code drafting, and manuscript and response editing. Instructions required verification of numerical claims against primary reports, separation of models and evaluation units, explicit recording of missing or inconsistent information, preservation of the original figure formats, and clear scientific English. Source locations and executed code are provided in Supplementary Dataset S1, and the assistance workflow is described in Supplementary Material S6.
2.5. Risk of Bias Assessment
QUADAS-2 was used to assess patient selection, the index test, the reference standard, and flow and timing. Applicability was considered separately for patient selection, the index test and the reference standard [33]. Supplementary Material S2 provides the 11 signalling responses and supporting rationales for each report. The assessment target was radiographically visible calcification; agreement with image annotations was not interpreted as confirmation of vascular disease or stenosis. The assessment did not involve independent duplicate reviewer adjudication. Traffic-light and domain-summary plots were generated in R using robvis [34]. All seven domains are displayed without an overall study rating, and each of the 20 reports receives equal weight in the domain summaries.
Use of evaluation data to select the reported architecture, training epoch or operating threshold, without a subsequent independent final evaluation, was considered a high-risk feature in the index-test domain. Insufficient reporting was distinguished from documented model selection using evaluation data.
An unclear judgement indicates that the available information did not support a low- or high-risk judgement. “Not reported” identifies information absent from the assessed source. Assessments were based on 19 complete published reports and the complete associated 2018 Kats preprint. For Kats, the assessment source is identified explicitly because the final journal full text was not verified. No additional dental-AI checklist assessment is claimed.
2.6. Statistical Analysis and Data Synthesis
Evidence was grouped by target, imaging modality, task and evaluation unit. The primary quantitative synthesis was restricted to direct binary classification of prepared cervical ROIs on panoramic radiographs for radiographically visible carotid artery calcification (CAC), with recoverable test contingency counts. Preparation could include automated anatomical localisation and cropping before classification. Lesion detection followed by aggregation into side or patient positivity did not meet this task definition. Sensitivity and specificity were pooled separately; precision, F1 and segmentation outcomes remained study-specific. A broader regional-presence sensitivity analysis is described below. This restricted estimand and its selection rule were established during revision.
One configuration per study is used in each analysis. Selection first requires conformity to the target, direct ROI-classification task and evaluation unit; within that eligible task, the highlighted classifier and principal reported operating point are retained. This selects Yoo’s CACSNet EfficientNet-B4, Carlos’s MobileNetV2 at the validation-selected Youden J threshold, and Kuwada System 2, which localises cervical regions with YOLOv7 and directly classifies the cropped regions with GoogLeNet [16,23,32]. Kuwada System 2 is selected for task compatibility, not because the authors preferred it: their discussion favours the operational simplicity of System 3, which localises and classifies regions simultaneously. Yoo compared five backbones on the test data before highlighting B4; its selection was not independent of test performance. Alternative configurations replace their corresponding primary configuration and never contribute additional independent studies.
Pooling is based on the specified radiographic target, task, unit and extractable counts, rather than an I2 cutoff or metric name alone. Differences in algorithm, region preparation and reference-label procedures remain sources of uncertainty within this narrow estimand. Yoo and Kuwada used CT-informed evaluation labels, whereas Carlos used expert-labelled public ROIs [16,23,32]. The summary concerns agreement with each study’s radiographic reference labels, not a uniform clinical reference standard for carotid disease.
2.6.1. Outcome Definitions and Restricted Meta-Analysis
Sensitivity is TP/(TP + FN), specificity is TN/(TN + FP), and precision is TP/(TP + FP) at the stated unit. F1 is 2TP/(2TP + FP + FN), a derived metric rather than an independent binomial proportion. Pixel means, cross-validation averages and lesion-matching outcomes are not assigned the denominator of the complete patient or image dataset.
For each eligible binary outcome, x is the number of correct classifications among n reference-positive ROIs (sensitivity) or reference-negative ROIs (specificity). The logit effect is y = ln[x/(n − x)], with approximate within-study variance v = 1/x + 1/(n − x). Between-study variance τ2 is estimated by restricted maximum likelihood (REML), with inverse-variance weights w = 1/(v + τ2). The pooled logit and confidence limits are transformed back to proportions. Modified Knapp–Hartung (mKH) intervals use variance max(1, q)/Σw, where q = Σw(y − pooled logit)2/(k − 1), and the t distribution with k − 1 degrees of freedom [35,36]. No zero cells occur, so no continuity correction is applied. Individual-study intervals in the forest plots are exact Clopper–Pearson binomial intervals; these differ from the logit variances used for weighting.
With only three primary studies, mKH can be conservative, while within-study logit variances remain approximate because some error cells contain only one or two observations [35,36]. The analysis is exploratory. A full bivariate or hierarchical summary receiver-operating-characteristic model would require estimating a poorly supported between-study covariance structure; it was not fitted to this small set [37]. Separate univariate models do not estimate the between-study sensitivity–specificity covariance and do not provide a joint confidence or prediction region. No prediction interval, publication-bias test or inferential modality comparison is presented. The forest plots show REML-based I2 = 100τ2/(τ2 + s2), where s2 is the typical within-study logit variance; full formulas and precision are supplied with the code [38]. A zero estimate does not establish homogeneity.
The base variances and individual intervals assume independent ROIs. Neither the individual-study intervals nor the pooled intervals incorporate an empirical adjustment for patient-level clustering. Bilateral or repeated observations may be correlated, and patient identifiers and intraclass correlations were unavailable. Sensitivity scenarios multiply the within-study logit variances of all three primary studies by 1.5 and 2.0; these are explicit assumptions, not estimated cluster corrections or bounds. Further analyses replace Carlos’s threshold, Yoo’s backbone or Kuwada’s system, or omit Kuwada. A broader regional-presence analysis replaces Kuwada with Mitsuya System 2 side results, avoiding simultaneous use of potentially overlapping cohorts. Mitsuya determines side positivity from detected lesions rather than direct classification of a prepared ROI [17]. A common-binomial calculation is supplied only as a restrictive sensitivity analysis assuming one homogeneous probability and independent ROIs.
The restricted meta-analyses were run in Stata 19 on 13 November 2026. Native meta esize and meta summarise commands implemented the logit-REML models and truncated Knapp–Hartung intervals, and meta forestplot generated the forest plots [38]. The native estimates and confidence limits agreed with a separate Python implementation at the reported precision. Axis formatting after export did not change estimates, intervals, weights or data coordinates. Supplementary Dataset S1 contains the inputs, full-precision results, execution logs and code. Adding the earlier reports to the narrative synthesis did not alter the pooled inputs or require a new meta-analysis; the original Stata forest plots are retained.
2.6.2. Modality Comparison and Non-Independent Data
Panoramic and CBCT studies were described separately without an inferential between-modality test. The earlier indirect comparison was withdrawn because modality was confounded with target, dataset, model, reference standard and evaluation unit. Its nonsignificant result did not establish equivalence [39]. The restricted meta-analysis included only panoramic ROI classifiers and could not answer a modality-comparison question. Possible cohort overlap was recorded, and sample counts were not converted into totals of independent patients. Kuwada and Mitsuya were assigned to one potentially overlapping cohort family, with at most one contribution from that family in each pooled analysis.
3. Results
3.1. Study Selection
The database searches identified 241 records: 29 from PubMed, 25 from Web of Science and 187 from Scopus. After removal of 52 duplicates, 189 records underwent title and abstract screening. We excluded 167 records and retrieved all 22 reports sought for full-text assessment. The author-reconciled 22-report inventory comprised 17 included reports and five exclusions before withdrawal of the lower date restriction.
Withdrawal of that restriction restored Sawagashira 2011 and Harada 2013 from the five exclusions. Sawagashira 2013, which was documented separately in the revision materials, was assessed as one additional report outside the original 22. Across the original and revision pathways, 23 reports were assessed, 20 were included, and three were excluded (Supplementary Material S3). Lee et al. (2022) remained included because calcification-specific outcomes could be extracted from the broader dental-anomaly evaluation [14]. The 20 reports do not represent 20 independent cohorts.
The three excluded reports were Friedlander 2010, a letter/commentary without an original AI diagnostic evaluation; Takahashi 2014, which did not meet the English-language criterion; and Alves 2014, a literature review [40,41,42]. Sawagashira 2011, Sawagashira 2013 and Harada 2013 were included in the narrative synthesis and risk-of-bias assessment [11,12,13]. Three reports met the restricted criteria for the primary meta-analysis. The study-selection process is summarised in Figure 1.
Figure 1.
PRISMA 2020 flowchart. The original 22 reports and one additional report assessed during revision (Sawagashira et al. [12]) yielded 23 full-text assessments, 20 included reports and three exclusions. Three reports contributed to the restricted exploratory meta-analysis. Report-level decisions and related-cohort links are documented in Supplementary Material S3. Adapted from the PRISMA 2020 template [10] under CC BY 4.0. * Database-specific yields are shown; ** exclusions followed title and abstract screening.
3.2. Characteristics of the Included Studies
The 20 included reports comprise 15 panoramic radiography reports and five CBCT reports, published from 2011 to 2026. Targets include carotid calcifications, sialoliths, tonsilloliths, lymph-node calcifications, and mixed calcifications or ossifications. Evaluation tasks range from binary image classification to lesion detection and pixel segmentation. Expert image annotation is common, while corroboration with CT or other imaging is described in several reports, including Yoo, Kuwada, Mitsuya and Ishibashi [16,17,21,23]. These reference procedures establish different clinical claims and are recorded separately. The 20 reports are not treated as 20 independent datasets.
3.3. Diagnostic Performance
Several reports provided estimates for multiple tasks or models, requiring separate interpretation. Yoo reported sensitivity 0.980 for EfficientNet-B4 classification of cervical regions of interest; the value 0.756 refers instead to mean pixel-segmentation recall. Segmentation precision was 0.749, and Dice was 0.722. These classification and segmentation outcomes represent different tasks [23]. Cin reported model-specific sensitivity/precision/F1 triplets of 0.98/0.91/0.94 for the single-class model and 0.88/0.80/0.84 for the multiclass model; these model-specific results are reported separately [30]. Mitsuya reported lesion-level triplets of 0.81/0.68/0.74 for System 1 and 0.90/0.67/0.77 for System 2 [17].
Cin’s Table 1 reports single-class TP 2156, FP 211 and FN 35 across 1323 test axial images, giving sensitivity and precision denominators of 2191 reference-positive instances and 2367 positive predictions. The multiclass counts are TP 1989, FP 478 and FN 247, with corresponding denominators 2236 and 2467. These are detection instances, not patients or verified unique three-dimensional lesions. The reported metrics do not all equal ratios of the tabulated counts: for example, single-class count-derived F1 is 0.946 versus the reported 0.94. F1-curve maxima also differ from Table 1 in the same study, and the curve thresholds are not explicitly linked to the tabulated operating points. Reported scores and count-derived quantities are therefore retained separately; the full text does not resolve their aggregation or rounding [30].
Lee et al. provide separate calcification outcomes from a Faster R-CNN detection system [14]. Table 3 in Lee et al. [14] defines positive observations as labelled objects and negative observations as images. CAC sensitivity is 69/72 (0.9583) at the object level, whereas specificity is 1274/1328 (0.9593) among negative images; these values do not form a common-unit 2 × 2 table. Table 2 in Lee et al. [14] reports CAC precision of 0.42331, but Table 3 in the same study gives 69 true detections among 126 predictions (0.54762). Both are retained as a source discrepancy. IoU > 0.5 is the localisation-matching criterion, not a probability cutoff. The target-specific results remain descriptive, outside the prepared-ROI classification synthesis.
The earlier trained machine-learning reports used lesion detection rather than direct binary classification of prepared cervical ROIs. Sawagashira 2011 detected 88 of 94 lesions in 34 positive images, with 4.4 false positives per image; at least one lesion was detected in 33 of 34 positive cases [11]. Sawagashira 2013 expanded the database to 100 images and reported 90% lesion sensitivity at 4.3 false positives per image over repeated train/test splits [12]. Harada evaluated a support-vector-machine pipeline in 170 positive images containing 219 calcification regions; Table 2 in Harada et al. [13] reports 104 true detections and 1109 false positives. The denominator of the text’s 67% detection rate is unresolved, and 67% does not equal 104/219. The percentage is therefore not entered as verified diagnostic sensitivity. These reports broaden the narrative evidence while remaining outside the restricted ROI-classification meta-analysis.
Alajaji’s U-Net-based models report four configurations [24]. For selected axial images, sensitivity/precision/F1 were 1.00/0.90/0.95 for extracranial and 0.93/0.36/0.52 for intracranial calcifications; in the separate full-volume experiment, they were 0.92/0.13/0.22 and 0.96/0.02/0.04, respectively. The axial test sets contained 27 extracranial and 24 intracranial slices, and both full-volume targets used the same five reserved volumes. Table 1 in Alajaji [24] does not operationally define the confusion-metric counting unit or complete denominators. These image and volume sample sizes are therefore not assigned as sensitivity or precision denominators.
Nelson’s whole-volume CBCT classifier reports sensitivity 0.66, precision 0.79 and F1 0.72 [25].Table 3 in Nelson et al. [25] gives TP 26, FN 13, FP 7 and TN 39, implying 39 reference-positive and 46 reference-negative validation scans; Nelson's Table 1 and the Results instead specify 40 positive and 45 negative scans. Both descriptions total 85 scans. The source discrepancy and the uncertain relationship between these cells and the reported cross-validation averages are retained. Specificity is not separately reported; 39/46 is retained only as a count-based audit calculation, not a published outcome or pooled input.
Mahdian’s nnU-Net segmentation results distinguish extracranial carotid, intracranial carotid and vertebral calcifications [26]. Table 2 in Mahdian et al. [26] reports sensitivity 0.56/0.55/0.51, specificity 0.99 for each target and Dice 0.41/0.46/0.33, respectively. Bounding-box accuracies of 0.71/0.78/0.53 measure whether the predicted mask lies inside a three-dimensional box around the reference mask; they are not IoU or ordinary diagnostic accuracy. The 148-scan segmentation cohort is distinct from the 114-patient/135-region radiomics subset. Exact segmentation sensitivity/specificity counting units, denominators and averaging remain unspecified, and the reported ± quantities are not identified as SD or SE. Cardiovascular-event classifiers address a different target. These CBCT configurations remain descriptive and receive no weight in the panoramic ROI synthesis.
The primary quantitative set contains Yoo’s 130 test ROIs (TP 49, FP 1, FN 1, TN 79), Carlos’s 57 test ROIs (TP 22, FP 2, FN 1, TN 32), and Kuwada System 2’s 160 sides from 80 patients (TP 53, FP 11, FN 7, TN 89) [16,23,32]. Sensitivity denominators are 50, 23 and 60; specificity denominators are 80, 34 and 100, respectively. Yoo’s numerical classification threshold was not located; its segmentation-loss parameters are not diagnostic cutoffs. Carlos’s approximately 0.84 Youden threshold was selected on validation data. Kuwada states a class-2 prediction threshold >50% for the side predictions used in person aggregation, but does not separately restate the threshold used for the side results reported in Table 2 of the same study. Kuwada reports successful anatomical localisation in all 80 test images. The 347 regional observations are not 347 independent patients.
The restricted summary sensitivity is 0.9376 (95% mKH CI 0.5314–0.9950; Figure 2), with REML τ2 = 0.5144 and weights of 23.51%, 23.13% and 53.36% for Yoo, Carlos and Kuwada, respectively. Summary specificity is 0.9424 (0.5286–0.9958; Figure 3), with τ2 = 0.6618 and weights of 21.76%, 30.54% and 47.70%. REML I2 is 45.0% for sensitivity and 61.0% for specificity. These broad intervals and uncertain three-study heterogeneity estimates do not establish a precise generalizable performance estimate.
Figure 2.
Restricted exploratory meta-analysis of sensitivity for direct classification of prepared panoramic cervical ROIs. Configurations are Yoo CACSNet EfficientNet-B4, Carlos MobileNetV2 at the validation-selected Youden threshold, and Kuwada System 2. Sensitivity denominators are 50, 23 and 60 reference-positive regions. Squares show study proportions with area proportional to inverse-variance weight; horizontal bars show exact binomial 95% CIs. The diamond shows the back-transformed logit-REML estimate with modified Knapp–Hartung 95% CI. ROI independence is a working assumption; intervals are not adjusted for patient clustering. The horizontal axis uses logit spacing with probability labels.
Figure 3.
Restricted exploratory meta-analysis of specificity for the same three ROI-classification configurations. Denominators are 80, 34 and 100 reference-negative regions for Yoo, Carlos and Kuwada, respectively. Exact individual-study intervals and the logit-REML/mKH summary interval are shown. Interpretation is limited to the study-specific radiographic reference labels, with regional independence assumed. Neither individual-study nor pooled intervals incorporate an empirical patient-clustering adjustment. The horizontal axis uses logit spacing with probability labels. Squares represent individual-study specificity estimates, with their areas proportional to the inverse-variance weights. Horizontal lines indicate exact binomial 95% confidence intervals. The centre of the diamond represents the pooled specificity estimate, and its width represents the modified Knapp–Hartung 95% confidence interval.
Denominators differed materially across studies. Ajami Method A used 189 reference-positive axial slices for sensitivity and 313 positive predictions for precision, within 4005 slices from 16 test scans [22]. Ishibashi Model 2 used 40 reference sialoliths and 34 positive detections, respectively [21]. Yilmaz evaluated 104 labelled CAC foci in 65 positive test radiographs: YOLOv5x-seg gave TP 88, FP 16 and FN 16; v8x-seg gave 92, 25 and 12; v11x-seg gave 85, 6 and 19. These are clustered detection outcomes; a negative-image specificity cannot be recovered [28]. Carlos used 23 reference-positive regions and 24 positive predictions at the validation-selected Youden threshold; 264 was the training sample, while the test sample contained 57 regions [32]. Development dataset sizes cannot replace these metric-specific test denominators.
Song reported standalone-AI sensitivity of 0.774 for carotid calcification, 0.250 for lymph-node calcification and 0.188 for sialoliths [20]. The whole-image detector is outside the direct prepared-ROI classification task, regardless of its reported sensitivity. In addition, exact standalone-AI contingency counts remain unresolved: two 176-image reader sessions reused the same 26 lymph-node images, so 352 cannot be treated as independent AI test observations. Vinayahalingam reports aggregated test-fold predictions, but exact counts and a numerical operating threshold remain unavailable; its image-level metrics follow whole-image lesion detection [27]. Amitay’s patient sensitivity of 0.87 is a projection from corner performance and assumed patient composition, rather than an observed independent patient test result. Its projected specificity also differs between the reported summary and the expected-count table [29]. Katı’s Table 2 and Figure 4 interchange EfficientNetB0/B1 labels; table-reported values are retained without assigning the conflicting matrices [31]. These outcomes remain study-specific.
Sensitivity analyses are reported in Supplementary Material S4. Replacing Yoo B4 with verified VGG16, ResNet101 or DenseNet121 configurations changed summary sensitivity to 0.8902, 0.9124 and 0.9124, respectively; the intervals remained wide. Yoo MobileNet v2 was excluded from these calculations because Figure 4b in the original study by Yoo et al. [23] conflicts with Table 2 in the same study. Replacing Carlos’s Youden point with the alternative operating point (TP 19, FP 1, FN 4, TN 33) gave sensitivity 0.8966 and specificity 0.9552. The source labels that the alternative threshold is approximately 0.98 in Yoo's Table 2 but 0.950 in Yoo's Figure 5; the discrepancy is retained [23,32]. Replacing Kuwada System 2 with System 3’s simultaneous regional localisation/classification (TP 52, FP 18, FN 8, TN 82) gave sensitivity 0.9354 and specificity 0.9349 [16]. Each replacement changes the corresponding configuration only. Replacing a backbone examines dependence on the selected configuration; it does not estimate or correct optimism introduced by selecting a model after test-set comparison.
The broader analysis replaced Kuwada with Mitsuya System 2 side results (TP 56, FP 16, FN 4, TN 84; 160 sides from 80 patients), yielding sensitivity 0.9494 (95% mKH CI 0.7549–0.9913) and specificity 0.9370 (0.3563–0.9975). This broadens the regional-presence estimand to positivity derived from lesion detection and does not establish the validity of mixing all study tasks. Mitsuya selected its 1000-epoch configuration using test F1 [17]. Omitting Kuwada and including no Mitsuya result left two studies, with sensitivity 0.9706 (0.0036–1.0000) and specificity 0.9683 (0.0014–1.0000); those upper limits are rounded. This omission demonstrates substantial uncertainty when the potentially overlapping cohort family is removed. No pooled scenario includes both reports.
Multiplying all three primary within-study logit variances by 2 gave sensitivity 0.9208 (95% CI 0.5048–0.9925) and specificity 0.9245 (0.5651–0.9914); the factor-1.5 scenario and full precision are supplied. These assumed multipliers do not correct unverified training/test leakage, model-selection optimism or reference-label limitations. Under the more restrictive homogeneous independent-binomial assumption, sensitivity was 124/133 = 0.9323 (exact 95% CI 0.8754–0.9686) and specificity was 200/214 = 0.9346 (0.8927–0.9638). Those intervals are conditional on stronger assumptions and are not the primary random-effects inference.
3.4. Interpretation by Imaging Modality
The reported evidence does not establish equivalent performance between panoramic radiography and CBCT. Differences in targets, reference labels, datasets and evaluation units prevent attribution of apparent performance differences to imaging modality alone. AI may assist opportunistic recognition of calcifications on a panoramic image obtained for a dental indication, but these studies do not establish clinical substitution for CBCT or accuracy against a uniform disease reference standard. Table 3 summarises the outcome definitions used in this review.
Table 3.
Outcome definitions and restrictions on interpretation.
3.5. Potential Cohort Overlap
The complete Kuwada and Mitsuya reports share the institution, ethics approval No. 496, recruitment years 2008–2023, 290 CAC cases and 290 controls, 215 bilateral and 75 unilateral cases, and CT-verification counts of 142 cases and 113 controls [16,17]. Both describe 500 development images and 80 test images with the same test-case composition, acquisition equipment and reader experience. This extensive concordance raises a substantial possibility of sample reuse. Neither report explicitly establishes cohort independence or confirms participant-level reuse; overlap is therefore treated as possible rather than proven. The extraction assigns both to one potentially overlapping cohort family, and no pooled scenario includes them together. The primary analysis uses Kuwada System 2, the broader task analysis replaces it with Mitsuya System 2, and an omission analysis excludes the family altogether. Their sample sizes are not added as independent patient totals.
Ajami and Mahdian describe Stony Brook CBCT archives with overlapping acquisition periods, and Mahdian identifies Ajami as the previous preliminary investigation [22,26]. Participant reuse is not established; this possible linkage is recorded without treating the cohorts as proven duplicates. Neither contributes to the restricted panoramic ROI pool.
Sawagashira 2013 explicitly expands the 2011 database from 34 to 100 images [11,12]. Both publications are retained as related reports, and their sample sizes are not added as independent participants. Neither contributes to the restricted ROI-classification pool.
3.6. Risk of Bias and Reporting Completeness
Figure 4 and Figure 5 show the four QUADAS-2 risk-of-bias domains and three applicability domains for all 20 reports. Supplementary Material S2 provides the 11 signalling responses and supporting rationales for each report. Nineteen complete published reports and the associated 2018 Kats preprint supported the assessments; the final 2019 Kats journal text was not verified [18,19]. Judgments are presented by domain, without assigning an overall low-, unclear- or high-risk rating to each study.
Figure 4.
QUADAS-2 traffic-light plot for 20 included report entries, generated using robvis (version 0.3.0.900) in R (version 4.5.0). Four risk-of-bias and three applicability domains are displayed separately. Green (+), low; yellow (−), unclear; red (×), high. Nineteen entries were assessed from complete published reports. Kats 2019 was assessed from its complete associated 2018 preprint; the final journal full text remains unverified. Yoo and Mitsuya have high index-test risk because the reported model selection used test performance. Source-based signalling responses and rationales are provided in Supplementary Material S2.
Figure 5.
QUADAS-2 domain summary for the current 20-report inventory, generated using robvis (version 0.3.0.900) in R (version 4.5.0). Bars show the percentages of low, unclear and high judgments in each of the four risk-of-bias and three applicability domains. Each report entry receives equal weight; the denominator is 20 for every domain. No overall study rating is calculated. Kats’s judgments refer to its associated 2018 preprint. Updated input data, the executed R plotting script and software session information are supplied with Supplementary Dataset S1.
Reporting limitations are study-specific. Ajami describes scanner settings and a board-certified oral and maxillofacial radiologist; Yoo identifies acquisition parameters and readers with more than 10 and 20 years of experience; Kuwada and Mitsuya describe equipment, exposure settings, readers with 8 and 38 years of experience, consensus assessment and CT verification of all evaluation participants [16,17,22,23]. Cin identifies two radiologists who established the categories and one who annotated all images, and Yilmaz describes acquisition and expert review [28,30]. Supplementary Material S1 records reported methods and information absent from each inspected source version. Missing reporting alone does not demonstrate poor acquisition, reader incompetence or data leakage.
The complete Alajaji report identifies the field of view and specialist-confirmed, calibrated annotations, but does not state the scanner model, exposure settings or voxel size [24]. Nelson reports the 3D Accuitomo device, 90 kVp, 7 mA, 250 µm voxels, two fields of view and a board-certified oral radiologist [25]. Mahdian reports three devices, acquisition ranges, three trained/calibrated annotators and review of all masks by a board-certified oral and maxillofacial radiologist [26]. Reader experience and explicit masking are not reported for these three studies. Their specialist image references address radiographic calcification, not independently confirmed vascular disease.
Lee reports named imaging devices and annotation by a dental-radiology expert, but the expert’s experience, explicit annotation blinding and patient-disjoint partitioning are not established in the inspected text [14].
The Kats preprint names the CS 8100 and Planmeca ProMax 2D devices and describes coordinated annotation and double-checking by two specialists in oral medicine and maxillofacial radiology [19]. It reports a 70%/10%/20% allocation, but not the splitting unit, exact test counts, patient-disjoint separation, numerical threshold or detection-matching criterion. Reader experience and explicit masking are also unstated. Its four risk-of-bias domains are unclear after assessment; patient-selection applicability is unclear, and index-test and reference-standard applicability are low for the radiographic annotation target. The 67% pathology-positive image composition alone does not establish case–control recruitment, and the augmentation description does not prove data leakage.
Alajaji’s risk-of-bias judgments are high for patient selection, unclear for the index test and low for reference standard and flow/timing. Nelson’s are unclear/high/low/unclear: Nelson's Figure 3 explicitly feeds validation accuracy and loss back into layer and hyperparameter configuration, with no separate untouched final test set described [25]. Mahdian’s are high/unclear/low/unclear; its positive-only sample and unresolved processing/evaluation flow are distinguished from the separate radiomics exclusions [26]. Patient-selection applicability is high for Alajaji and Mahdian and unclear for Nelson; index-test and reference-standard applicability are low for all three under the task-aware radiographic target.
Yoo and Mitsuya were both rated at high risk in the index-test domain [17,23]. Yoo highlighted EfficientNet-B4 after comparing five classification backbones on the test set; Mitsuya selected the 1000-epoch configuration using test-set F1. No separate final evaluation after these selections was described. The common concern is evaluation-data-informed model selection, whether the selected feature is architecture or training epoch. Yoo’s numerical classification threshold remains unreported; this is distinct from the documented architecture-selection concern.
The restored Sawagashira reports were rated high for patient selection and index-test risk because of selected samples and data-derived preprocessing thresholds [11,12]. Harada was rated high for patient selection and unclear for the index test, reference standard and flow/timing [13]. Its development/evaluation separation and reference procedures were insufficiently reported; leakage was not assumed. These source-based judgments and their signalling responses are documented separately in Supplementary Material S2.
4. Discussion
Three reports provided compatible binary counts for an exploratory meta-analysis of direct classification of prepared panoramic cervical ROIs. Summary sensitivity and specificity were approximately 0.94, but their mKH confidence intervals extended from approximately 0.53 to 1.00. These wide intervals reflect the uncertainty of a three-study synthesis with sparse error cells and unverified independence of regional observations. The interval adjustment addresses uncertainty in the pooled estimate; it does not remove study bias or within-patient dependence [35,36]. Individual-study findings and the alternative-configuration analyses therefore remain important when interpreting the summary.
The three classifiers differed in reference procedures, region preparation and model selection. Yoo highlighted an architecture after comparing test-set performance, Carlos selected its principal operating point using validation data, and Kuwada used automated anatomical localisation before ROI classification [16,23,32]. The alternative-configuration analyses show how the pooled estimates depend on these choices. They cannot measure or correct the optimism introduced when a model is chosen using its test results. Sensitivity also depends on the reference-positive population and the definition of a detected finding; precision depends on prevalence and false-positive behaviour. Results from enriched datasets therefore cannot be transferred directly to routine screening populations.
Several regions from the same person may be correlated. The base meta-analysis assumed independence, while the variance-inflation scenarios examined specified departures from that assumption without estimating a cluster correction. Possible overlap between Kuwada and Mitsuya was handled by allowing only one report from that cohort family in any pooled scenario and by omitting the family in a sensitivity analysis. A joint diagnostic model would not resolve incompatible evaluation units, uncertain independence or biased reference labels [37].
Comparisons between panoramic radiography and CBCT were indirect and confounded by calcification target, annotation standard and evaluation design. A nonsignificant indirect subgroup comparison cannot demonstrate equivalence [39]. Recognising a radiographic calcification is also a different task from diagnosing carotid stenosis or predicting a vascular event. Although radiographic carotid calcification has been associated with later vascular events [2], that association does not validate the AI systems reviewed here for those clinical outcomes.
Aggarwal et al.’s review of deep learning in medical imaging provides broader context for variation in diagnostic performance and validation methods [43]. In this dental evidence base, important concerns were enriched case selection, uncertain separation of observations from the same patient, incompletely reported thresholds, discrepancies within primary reports and possible cohort overlap. Lack of external validation limits generalisability, although it does not by itself prove overfitting or biased internal testing.
This review also has limitations. Registration was retrospective, and the restricted pooling rule and sensitivity analyses were developed during revision. The original searches did not explicitly include SVM or computer-aided-detection terminology, and native database execution histories were unavailable for retrospective verification [15]. Targeted checking of known reports and restoration of the earlier studies do not establish complete retrieval. The QUADAS-2 assessment did not involve independent duplicate reviewer adjudication, and the Kats assessment relied on its associated preprint. We withdrew the post hoc lower date restriction and reconciled the report-level selection records. Including the earlier trained classifiers broadened the narrative evidence without changing the restricted pooled inputs; it does not establish an improvement in performance over time.
Future evaluations should define the intended clinical use, recruit representative populations and separate patients across development and test datasets. Reports should specify the reference standard, operating threshold, lesion-matching rule and evaluation unit and provide complete contingency counts. External validation and analyses that account for clustered observations would improve the reliability of subsequent syntheses. Studies of referral decisions and patient outcomes are needed to establish clinical utility.
5. Conclusions
AI systems showed promising performance for identifying radiographic calcifications in selected dental-image datasets. The restricted exploratory meta-analysis of three panoramic ROI classifiers was imprecise and subject to model-selection and dependence concerns. Its findings do not establish patient-level screening accuracy, clinically verified vascular disease detection or equivalence between panoramic radiography and CBCT. Each estimate should be interpreted in relation to its target, task, reference standard, evaluation unit and test population.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/medicina62122346/s1. Supplementary methods and results, comprising S1, Study extraction and reporting verification; S2, QUADAS 2 signalling and applicability; S3, Search and eligibility decisions; S4, Restricted exploratory meta-analysis and reproducibility; S5, Original search strategies and coverage; S6. Assistance used during revision. Supplementary Dataset S1: Scientific data and reproducibility materials. The completed PRISMA 2020 checklist and editable flowchart are also provided. The supplementary document also contains Figure S1: QUADAS-2 traffic-light plot for 20 report entries; Figure S2: QUADAS-2 domain summary for the same 20 report entries; Table S1: Verified primary counts; Table S2: Primary results and weights; and Table S3: Primary and sensitivity scenarios.
Author Contributions
Conceptualisation and resources, A.A. (Abdullah Alqarni); methodology, formal analysis and supervision, H.A.A.; investigation and formal analysis, R.M.; data curation and writing—original draft, A.N.A.; writing—review and editing and project administration, A.A. (Ahmad Alahmari); writing—original draft and visualisation, A.A. (Abdulmajeed Almuaddi); methodology and resources, M.S.H. All authors have read and agreed to the published version of the manuscript.
Funding
The authors extend their appreciation to the Deanship of Research and Graduate Studies at King Khalid University for funding this work through the Literature Review Program under grant number RA.KKU/5/47.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Supplementary Dataset S1 contains the 78 extraction records from 20 reports, acquisition and reference-standard information, QUADAS-2 signalling responses and rationales, and the reconciled selection inventory. It also includes the unchanged meta-analysis inputs and full-precision Stata outputs, execution logs, original forest plots, and R code executed using R (version 4.5.0) and robvis (version 0.3.0.900), together with the corresponding input data for the risk-of-bias figures.
Acknowledgments
The authors acknowledge the use of ChatGPT (OpenAI; GPT-6 Astra Pro) for assistance and guidance during manuscript preparation and revision, including language refinement, organization of research materials, and support with data verification and analytical documentation. All scientific interpretations, methodological decisions, and final manuscript content were reviewed and approved by the authors, who take full responsibility for the work.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Maia, P.R.L.; Tomaz, A.F.G.; Maia, E.F.T.; Lima, K.C.; de Oliveira, P.T. Prevalence of soft tissue calcifications in panoramic radiographs of the maxillofacial region of older adults. Gerodontology 2022, 39, 266–272. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lim, L.Z.; Koh, P.S.F.; Cao, S.; Wong, R.C.W. Can carotid artery calcifications on dental radiographs predict adverse vascular events? A systematic review. Clin. Oral Investig. 2021, 25, 37–53. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Janiszewska-Olszowska, J.; Jakubowska, A.; Gieruszczak, E.; Jakubowski, K.; Wawrzyniak, P.; Grocholewicz, K. Carotid Artery Calcifications on Panoramic Radiographs. Int. J. Environ. Res. Public Health 2022, 19, 14056. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Almog, D.M.; Illig, K.A.; Carter, L.C.; Friedlander, A.H.; Brooks, S.L.; Grimes, R.M. Diagnosis of non-dental conditions. Carotid artery calcifications on panoramic radiographs identify patients at risk for stroke. N. Y. State Dent. J. 2004, 70, 20–25. [Google Scholar] [PubMed]
- Dief, S.; Veitz-Keenan, A.; Amintavakoli, N.; McGowan, R. A systematic review on incidental findings in cone beam computed tomography (CBCT) scans. Dentomaxillofac. Radiol. 2019, 48, 20180396. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Monsarrat, P.; Galibourg, A.; Nasr, K.; Telmon, N.; Maret, D. Incidental Findings in Dental Radiology are Concerning for Family Doctors. Open Med. Wars. 2019, 14, 467–478. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schwendicke, F.; Samek, W.; Krois, J. Artificial Intelligence in Dentistry: Chances and Challenges. J. Dent. Res. 2020, 99, 769–774. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Turosz, N.; Chęcińska, K.; Chęciński, M.; Brzozowska, A.; Nowak, Z.; Sikora, M. Applications of artificial intelligence in the analysis of dental panoramic radiographs: An overview of systematic reviews. Dentomaxillofac. Radiol. 2023, 52, 20230284. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Assiri, H.A.; Malwi, R.E.; Almuaddi, A.T.; Alshehri, A.B. Diagnostic accuracy of artificial intelligence in detecting soft tissue calcifications and ossifications on dental radiographs: A systematic review and meta-analysis. INPLASY 2026, INPLASY202660038. [Google Scholar] [CrossRef] [Scilit]
- Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ 2021, 372, n71. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sawagashira, T.; Hayashi, T.; Hara, T.; Katsumata, A.; Muramatsu, C.; Zhou, X.; Iida, Y.; Katagi, K.; Fujita, H. An automatic detection method for carotid artery calcifications using top-hat filter on dental panoramic radiographs. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. 2011, 2011, 6208–6211. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sawagashira, T.; Hayashi, T.; Hara, T.; Katsumata, A.; Muramatsu, C.; Zhou, X.; Iida, Y.; Katagi, K.; Fujita, H. An automatic detection method for carotid artery calcifications using top-hat filter on dental panoramic radiographs. IEICE Trans. Inf. Syst. 2013, E96-D, 1878–1881. [Google Scholar] [CrossRef] [Scilit]
- Harada, H.; Muneyasu, M.; Asano, A.; Uchida, K.; Taguchi, A. Improved detection method for carotid artery calcification in dental panoramic radiographs considering local features. In Proceedings of the 2013 International Symposium on Intelligent Signal Processing and Communication Systems, Naha, Okinawa, Japan, 12–15 November 2013; pp. 537–542. [Google Scholar] [CrossRef] [Scilit]
- Lee, S.; Kim, D.; Jeong, H.-G. Detecting 17 fine-grained dental anomalies from panoramic dental radiography using artificial intelligence. Sci. Rep. 2022, 12, 5172. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rethlefsen, M.L.; Kirtley, S.; Waffenschmidt, S.; Ayala, A.P.; Moher, D.; Page, M.J.; Koffel, J.B.; PRISMA-S Group. PRISMA-S: An extension to the PRISMA statement for reporting literature searches in systematic reviews. J. Med. Libr. Assoc. 2021, 109, 174–200. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kuwada, C.; Mitsuya, Y.; Fukuda, M.; Yang, S.; Kise, Y.; Mori, M.; Naitoh, M.; Ariji, Y.; Ariji, E. Area detection improves the person-based performance of a deep learning system for classifying the presence of carotid artery calcifications on panoramic radiographs. Oral Radiol. 2026, 42, 91–100. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mitsuya, Y.; Kuwada, C.; Yang, S.; Kise, Y.; Mori, M.; Takashi, Y.; Nishiyama, M.; Ishikawa, N.; Naitoh, M.; Ariji, E. Side- and patient-based performance of a deep learning system based on the results of individual detection of carotid artery calcifications on panoramic radiographs. Imaging Sci. Dent. 2026, 56, 83–92. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kats, L.; Vered, M.; Zlotogorski-Hurvitz, A.; Harpaz, I. Atherosclerotic carotid plaque on panoramic radiographs: Neural network detection. Int. J. Comput. Dent. 2019, 22, 163–169. [Google Scholar] [PubMed]
- Kats, L.; Vered, M.; Zlotogorski-Hurvitz, A.; Harpaz, I. Atherosclerotic carotid plaques on panoramic imaging: An automatic detection using deep learning with small dataset. arXiv 2018, arXiv:1808.08093. [Google Scholar] [CrossRef] [Scilit]
- Song, Y.B.; Jeong, H.-G.; Kim, C.; Kim, D.; Kim, J.; Kim, H.J.; Park, W. Comparison of detection performance of soft tissue calcifications using artificial intelligence in panoramic radiography. Sci. Rep. 2022, 12, 19115. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ishibashi, K.; Ariji, Y.; Kuwada, C.; Kimura, M.; Hashimoto, K.; Umemura, M.; Nagao, T.; Ariji, E. Efficacy of a deep leaning model created with the transfer learning method in detecting sialoliths of the submandibular gland on panoramic radiography. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 2022, 133, 238–244. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ajami, M.; Tripathi, P.; Ling, H.; Mahdian, M. Automated Detection of Cervical Carotid Artery Calcifications in Cone Beam Computed Tomographic Images Using Deep Convolutional Neural Networks. Diagnostics 2022, 12, 2537. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yoo, S.-W.; Yang, S.; Kim, J.-E.; Huh, K.-H.; Lee, S.-S.; Heo, M.-S.; Yi, W.-J. CACSNet for automatic robust classification and segmentation of carotid artery calcification on panoramic radiographs using a cascaded deep learning network. Sci. Rep. 2024, 14, 13894. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Alajaji, S.A.; Amarin, R.; Masri, R.; Tavares, T.; Kumar, V.; Price, J.B.; Sultan, A.S. Detection of extracranial and intracranial calcified carotid artery atheromas in cone beam computed tomography using a deep learning convolutional neural network image segmentation approach. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 2024, 138, 162–172. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Nelson, J.; Vaddi, A.; Tadinada, A. Can convolutional neural networks identify external carotid artery calcifications? Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 2024, 138, 142–148. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mahdian, M.; Ahmed, A.A.; Bhattacharya, M.; Prasanna, P. Deep learning and radiomics-based vascular calcification characterization in dental cone beam computed tomography as a predictive tool for cardiovascular disease: A proof-of-concept study. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 2025, 139, 462–469. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Vinayahalingam, S.; van Nistelrooij, N.; Xi, T.; Heiland, M.; Bressem, K.; Rendenbach, C.; Flügge, T.; Gaudin, R. Detection of carotid plaques on panoramic radiographs using deep learning. J. Dent. 2024, 151, 105432. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yılmaz, B.G.; Altun, S.; Bayrakdar, İ.Ş. Evaluation of deep learning-based segmentation models for carotid artery calcification detection in panoramic radiographs. Oral Radiol. 2026, 42, 228–235. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Amitay, M.; Barnett-Itzhaki, Z.; Sudri, S.; Drori, C.; Wase, T.; Abu-El-Naaj, I.; Ben-Ari, M.K.; Rieck, M.; Avni, Y.; Pogozelich, G.; et al. Deep convolution neural network for screening carotid calcification in dental panoramic radiographs. PLoS Digit. Health 2023, 2, e0000081. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cin, L.; Duman Tepe, R.; Cansız, E.; Ozcan, I.; Bayrakdar, I.S.; Cakir Karabas, H. Artificial intelligence-assisted detection of soft tissue calcifications and ossifications in CBCT. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 2026, 141, 548–557. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Katı, E.; Baybars, S.C.; Danacı, Ç.; Tuncer, S.A. Applying deep learning techniques to identify tonsilloliths in panoramic radiography. Sci. Rep. 2025, 15, 24773. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Carlos, T.M.J.; José da Cunha, M.; Morais, A.S.; Tofoli, F.L. Deep Learning-Based Detection of Carotid Artery Atheromas in Panoramic Radiographs. Bioengineering 2026, 13, 95. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Whiting, P.F.; Rutjes, A.W.S.; Westwood, M.E.; Mallett, S.; Deeks, J.J.; Reitsma, J.B.; Leeflang, M.M.G.; Sterne, J.A.C.; Bossuyt, P.M.M.; QUADAS-2 Group. QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies. Ann. Intern. Med. 2011, 155, 529–536. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- McGuinness, L.A.; Higgins, J.P.T. Risk-of-bias VISualization (robvis): An R package and Shiny web app for visualizing risk-of-bias assessments. Res. Synth. Methods 2021, 12, 55–61. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Röver, C.; Knapp, G.; Friede, T. Hartung-Knapp-Sidik-Jonkman approach and its modification for random-effects meta-analysis with few studies. BMC Med. Res. Methodol. 2015, 15, 99. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Friede, T.; Röver, C.; Wandel, S.; Neuenschwander, B. Meta-analysis of two studies in the presence of heterogeneity with applications in rare diseases. Biom. J. 2017, 59, 658–671. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Reitsma, J.B.; Glas, A.S.; Rutjes, A.W.S.; Scholten, R.J.P.M.; Bossuyt, P.M.; Zwinderman, A.H. Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J. Clin. Epidemiol. 2005, 58, 982–990. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- StataCorp. Stata 19 Meta-Analysis Reference Manual. Stata Press: College Station, TX, USA, 2025; Available online: https://www.stata.com/manuals/meta.pdf (accessed on 10 November 2026).
- Altman, D.G.; Bland, J.M. Statistics notes: Absence of evidence is not evidence of absence. BMJ 1995, 311, 485. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Friedlander, A.H. Calcified carotid artery imaged by computed tomography. J. Oral Maxillofac. Surg. 2010, 68, 1457–1458, author reply 1458. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Takahashi, R.; Muramatsu, C.; Hara, T.; Hayashi, T.; Katsumata, A.; Zhou, X.; Fujita, H. Improvements to an automated method for detecting carotid artery calcifications by adopting a positional feature and feature selection. Nihon Hoshasen Gijutsu Gakkai Zasshi 2014, 70, 526–533. (In Japanese) [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Alves, N.; Deana, N.F.; Garay, I. Detection of common carotid artery calcifications on panoramic radiographs: Prevalence and reliability. Int. J. Clin. Exp. Med. 2014, 7, 1931–1939. [Google Scholar] [PubMed]
- Aggarwal, R.; Sounderajah, V.; Martin, G.; Ting, D.S.W.; Karthikesalingam, A.; King, D.; Ashrafian, H.; Darzi, A. Diagnostic accuracy of deep learning in medical imaging: A systematic review and meta-analysis. npj Digit. Med. 2021, 4, 65. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Published by MDPI on behalf of the Lithuanian University of Health Sciences. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.