Abstract
Broad-linewidth lasers challenge Alamouti coherent-lite receivers because carrier recovery combines conjugated branch terms from adjacent time slots. This work compares single-error and projected paired-error complex branch-correction rules in a four-branch Alamouti coherent-lite receiver using identical frozen FIR branch streams. To avoid the Nyquist-edge ambiguity of the 100 gigasamples per second (GSa/s) reference model, the key experiments are repeated with a 200 GSa/s front end. The 200 GSa/s results form the principal basis for the robustness conclusions, while the 100 GSa/s results are retained as reference-model diagnostics. Across two independent static, lossless Jones-matrix ensembles at 2 MHz per laser, threshold failures decrease from 21/240 with single-error tracking to 2/240 with paired-error tracking, and the paired rule gives lower BER in 217/240 matched records. FIR-training controls show that training quality materially affects both trackers, so the receiver-level improvement cannot be attributed solely to the downstream paired-error correction. These conclusions are limited to the simulated static, lossless SOP transformations and idealized receiver model considered here.