Abstract
Measuring wind direction in a marine environment requires high accuracy and robust performance under atmospheric conditions. Traditional potentiometric sensors suffer from premature wear and sliding contacts that degrade their performance. Magnetic encoders are contactless but may be susceptible to electromagnetic interference and magnet degradation. The latest-generation solutions based on ultrasonic technology often face limitations regarding cost, footprint, and precipitation sensitivity. This paper proposes a wind direction sensor based on an innovative stacked-coil inductive architecture, which combines multi-period accuracy within a 43 mm diameter footprint and potential for reduced costs. Static, semi-static, and dynamic tests were conducted in the laboratory using a motorized rotation stage and a wind tunnel. In the static tests, the sensor alone agrees with the reference stage within ±0.08° (including the stage’s own ≤ 0.05° accuracy), with a maximum standard deviation of 0.019° and a hysteresis up to 0.026°. Coupled to a commercial wind vane, the assembled prototype shows a mean error within approximately ±2° at wind speeds of 6 m/s and above, and an underdamped step response with a damping ratio between 0.25 and 0.32.
1. Introduction
Knowing the wind direction is of utmost importance for most applications in the maritime sector. Starting with sailboats, autonomous navigation systems have been developed over the years [1]. These systems rely on accurate wind direction measurements to optimize sail positioning, offering significant advantages in terms of sailing efficiency [2].
Beyond sailboats, knowing the wind direction is also essential for motorized ships. In delicate maneuvers, such as docking or the approach of multiple vessels, the effects of wind and tide on a ship’s motion are critical to the successful completion of the operation.
Furthermore, intelligent control systems have been studied in recent years. Especially for commercial applications, where ships travel long distances and carry heavy loads, harnessing the wind as an additional source of propulsion offers a substantial advantage in terms of navigation efficiency and fuel savings [2].
Confirming this trend, in 2016 CE Delft presented a study on the market potential and technological barriers of wind-powered propulsion systems [3]. The research indicated a potential for 3700–10,700 systems to be installed by 2030, highlighting a strong interest in autonomous navigation assistance systems within the commercial maritime sector.
Historically, wind direction measurement has been obtained through mechanical wind vanes coupled with rotary potentiometers. Despite their simplicity, potentiometric sensors are prone to mechanical degradation and wear of the sliding contacts. The typical accuracy of this kind of sensor is within a few degrees, depending on the design of the vane [1].
To overcome these limitations, magnetic encoders have been introduced as a contactless alternative. Although they offer significant advantages in terms of reduced footprint and power consumption, they are sensitive to external electromagnetic fields, and magnet degradation can be a concern over long-term usage.
More recently, Ultrasonic Sensors (US) have emerged as the state-of-the-art solution for wind speed and direction sensing. These sensors are based on the time-of-flight principle, calculating the speed and direction of the wind by measuring the propagation delay of acoustic signals. While US offer the advantage of having no moving parts, their performance is affected by parasitic effects, such as the shadow effect, and environmental factors such as precipitation and dust, which can negatively interact with the acoustic waves [4,5]. Although these sensors typically achieve wind direction accuracy within a few degrees, recent studies have demonstrated that, through optimizations based on Computational Fluid Dynamics (CFD) simulations and controlled conditions, measurement error can be reduced to [6]. Furthermore, US generally require a larger physical footprint and involve higher costs, which can limit their applicability in compact or low-budget autonomous systems.
To address the limitations of existing solutions, namely direct mechanical contact, magnetic interference/degradation, and the environmental/cost-related drawbacks, in this paper we propose an innovative Inductive Position Sensor (IPS) based on a stacked-coil design. This solution aims to offer a reliable, contactless and compact measurement while mitigating the trade-offs between accuracy, robustness, compactness, and cost-effectiveness.
Compared with alternative sensing technologies, printed circuit board (PCB)-based IPSs are expected to offer high resilience to harsh environmental conditions, primarily due to their contactless and ratiometric operating principles. Since the coupling is magnetic, humidity, dust, and other non-conductive contaminants are expected to have a limited effect, in environments where optical or capacitive solutions may be adversely affected [7,8]. In addition, the differential coil topology is reported to provide strong immunity to temperature-induced drifts [9]. Recent studies have also demonstrated a high degree of robustness against magnetic stray fields [9,10]. These characteristics make PCB-based IPSs particularly well suited to industrial and automotive applications, where robustness and immunity to electromagnetic interference are essential requirements [7,8,11].
The marine environment is similarly characterized by particularly harsh conditions, where humidity, temperature, and vibrations can negatively affect the performance of sensors. In this field, IPS have great potential, since their contactless design and the absence of magnets are expected to reduce mechanical wear and sensitivity to external electromagnetic fields. The operating principle of these sensors, which will be discussed in more detail later, is based on changes in mutual inductance between a transmitter coil and a set of receiver coils; consequently, a limited sensitivity to temperature fluctuations and humidity is expected. These expectations derive from the operating principle and from the literature; no environmental or aging tests were performed in this work.
Finally, the cost-effectiveness of inductive position sensors is structurally driven by their material composition. Recent analyses on coil-coupling architectures confirm that substituting standard resolvers with PCB-integrated inductive frameworks reduces manufacturing complexity [10]. This design entirely cuts out precision wound-wires and costly magnetic materials, achieving high precision with standard, low-cost metallic components. Moreover, being based on established, high-volume PCB manufacturing rather than precision wound-wires or calibrated magnets, this architecture is structurally compatible with low-cost, large-scale production. Although a cost comparison is beyond the scope of this work, an estimate of the cost of the electronic components and PCBs is provided at the end of Section 2.2.
This paper is organized as follows: Section 2 presents the operating principle of an IPS, along with a detailed description of the sensor’s design, covering both its electrical and mechanical aspects; Section 3 describes the measurement setup and the tests conducted; Section 4 presents the results obtained; Section 5 discusses them and the limitations of this work; finally, Section 6 summarizes the main findings.
2. Sensor Description
2.1. Working Principle
Figure 1a illustrates the basic structure of an inductive position sensor in the absence of a target. It consists of a transmitter coil and two receiver coils. The transmitter is powered by an alternating current, generating a varying electromagnetic field in the sensor area. A voltage is induced in the receiver coils according to the Faraday-Neumann–Lenz law. The receiver coils are designed such that, in the absence of a target, the total linked flux is zero.
Figure 1.
Example of an IPS without the target (a) and with the target (b).
The introduction of a conductive target (typically aluminum or copper) modifies this condition (Figure 1b) by shielding the area of the receiving coils located beneath its copper zones. This perturbation alters the mutual inductance between the transmitter and the receiver coils sinusoidally with respect to the target’s angular position.
Finally, the receiver coils are spatially phase-shifted by , ensuring that the two induced voltages are in quadrature, allowing for unique determination of the target’s position.
Figure 2 shows an illustrative example built ad hoc of the voltages present in the coils of an inductive position sensor. As can be seen in the figure, in this example the receiving coils have a single electrical period; therefore, the modulating signal has an electrical period equal to the mechanical period of the target’s rotation.
Figure 2.
Example of the transmitter coil signal (a) and the two induced voltages on the receiver coils (b,c).
The following equations describe the operating principle of the sensor. The variables are defined as follows: A represents the amplitude of the excitation voltage, is the excitation frequency of the transmitter, k is the transformation ratio between the transmitter and the receiver coils, t is the time, and is the electrical angular position of the target.
The induced voltages are, therefore, modulated in amplitude according to the mechanical position of the target. To extract the electrical angle , it is first necessary to demodulate the two received signals and then apply the atan2 function as shown in Equation (4). It should be noted that, since the receiver coils in this example have a single electrical period, the electrical angle obtained corresponds directly to the mechanical angular position of the target.
Although single-period IPSs provide an absolute angle and occupy a small area, they typically exhibit low accuracy and are highly sensitive to misalignments. To address these limitations, multi-period receiver solutions can be employed. Assuming an N-period sensor, the accuracy is improved by a factor of N, and the system is significantly more robust against misalignments [9]. The disadvantage of this configuration is that, after the atan2 operation shown in Equation (4), the output no longer represents the absolute angular position directly. To achieve a high-accuracy, absolute sensor, one possible solution consists of working with two pairs of receiving coils with the following options:
- Coarse-Fine method: using a single-period coil pair and an N-period coil pair. The angle calculated from the single-period pair is used to identify the correct sector for the multi-period pair, which provides the high-accuracy position;
- Vernier method: using a pair of N and N-1 receiver coils, where the absolute angle is derived from the difference between the two calculated electrical angles.
Figure 3 shows a “Coarse-Fine” sensor design with a pair of receiver coils with periods 1 and 16. As expected, the footprint of this solution is significantly larger than that of a single-period design. Taking into account the peripheral electronics required to interface with the coils, such a sensor can reach a diameter of 10 cm [12]. A key contribution of this paper, which will be analyzed in detail in the following section, is to propose an alternative design capable of achieving the advantages of a multi-period configuration while significantly reducing the area occupied.
Figure 3.
Coarse-Fine, own design, example with 1–16 periods of the receiver coils.
On the basis of the working principle shown above, we can address the topic of sensor resistance to atmospheric conditions. The IEC 60945 and IEC 60068-2-52 standards [13,14] specify the following environmental test conditions for marine electronics:
- Salt mist generated from a 5% NaCl solution;
- Temperature range from −25 °C to 55 °C;
- Relative humidity of approximately 93% at 40 °C.
These are the conditions the sensor is expected to withstand. Although experimental verification is left for future work, comments can already be drawn from the sensor’s operating principle.
Since the coupling between the coils is magnetic, non-conductive contaminants such as moisture or dust have a limited effect on the measurement, unlike other technologies. Capacitive sensors, for example, are affected by changes in temperature and humidity because these factors alter the dielectric constant as perceived by the sensor itself. Optical sensors are particularly sensitive to dust, condensation and salt deposits, which can contaminate the optical path or the encoder disc and prevent the light from being read correctly by the electronics. Even a film of seawater ( S/m), although conductive, has a conductivity about seven orders of magnitude lower than that of the copper of the target ( S/m): at a frequency of a few MHz its skin depth is about 0.1 m, much larger than any realistic film thickness, so the eddy currents induced in it, and, therefore, its shielding effect on the field, are negligible.
As for magnetic sensors, the magnetic flux of the permanent magnets they contain can drift with temperature, which over time can degrade the sensor’s performance. In addition, because they operate with DC magnetic fields, they are inherently sensitive to continuous or low-frequency external magnetic fields. Inductive sensors, instead, do not contain any permanent magnets, and the operating frequency of their magnetic field is a few MHz, well above the fundamental and switching frequencies of motors and inverters.
In contrast, inductive sensors are sensitive to the presence of other conductive objects nearby, which can interfere with the field generated by the transmitting coil. To address this issue, the sensor can be enclosed in a housing that ensures a minimum distance between its sensitive part and any mounting hardware. Moreover, high humidity can compromise the mechanical integrity of the PCB by penetrating the laminate stack, and salt deposits can corrode the copper. Typical solutions include applying potting compound or conformal coating to create a protective layer that insulates the PCB.
2.2. Electrical Design of the Sensor
This section first describes the internal design of the inductive sensor at the PCB level, analyzing the design choices and components. Subsequently, the overall sensor structure, including its housing, is presented.
The sensor’s internal structure is based on a “Coarse-Fine” design. As previously described, this configuration contains two pairs of receiving coils: one with a single period and the other with 16 periods. This allows the sensor to directly provide the absolute angular position of the wind vane while enhancing both accuracy and robustness compared with a single-period design.
The primary challenge we faced was minimizing the sensor’s footprint so that it could be competitive with other technologies that typically have a smaller footprint. This goal was achieved by implementing a stacked configuration. The receiving coils were placed one above the other rather than in a side-by-side configuration.
The main challenge in designing such a stacked configuration is ensuring that the receiver coils remain mutually independent, thereby preventing cross-interference during operation. To achieve this, numerous configurations were simulated with IPS Magic software (version 3.0) [15], by varying the number of periods of the receiving coils. Among the configurations simulated, the 1- and 16-period pair was chosen because it keeps the two stacked receivers mutually independent and because it is a good compromise between size, performance and cost. A higher number of periods for the fine channel would improve the accuracy, but it would require a significantly larger sensor and blind vias, increasing the complexity and the cost. For the same reason, a standard 4-layer stackup was used instead of a custom one, which would be more expensive; the shape of the receivers was then optimized by simulation for this stackup. The dimensions in Table 1 follow from the same trade-off. Figure 4a illustrates the first and second layers of the stator PCB, while Figure 4b shows the third and the fourth ones.
Table 1.
Specifications of the coil and target PCBs.
Figure 4.
Receiving coils of the stator PCB: (a) first (red) and second (orange) layers; (b) third (light blue) and fourth (blue) layers. Grey dots indicate vias.
For the target, a thin, two-layer PCB was used, with the layer closest to the stator hosting the multi-period target, while the more distant layer is dedicated to the single-period target. This arrangement ensures that the multi-period target, which determines the sensor’s accuracy, sees a smaller air gap, yielding a stronger signal on the receiving coils and a higher signal-to-noise ratio. Since the 1-period receiver is farther from the target, it was necessary to make specific choices to ensure that the induced voltages were high enough to be processed by the electronics:
- The target’s PCB thickness is reduced to 0.6 mm;
- The nominal air gap separating the stator PCB from the target PCB is 0.5 mm;
- The single-period receiver was designed with two turns so that the induced voltage would be double [16]. This can be seen in Figure 4b.
Figure 5 illustrates a detailed view of the stackup for the design of both the stator and target PCBs.
Figure 5.
Stackup of the sensor’s stator and target PCBs.
Table 1 summarizes the main specifications of the coil PCB of the inductive sensor.
As can be seen in Figure 4b, the fourth layer houses several exposed pads. This is because the auxiliary electronics, necessary to drive the transmitter coil and read the receiver coils, are placed on a third PCB, which is attached to the board presented in Figure 4 through castellated pads.
Turning now to the design of the peripheral electronics, the coils interface is handled by the Renesas RAA2P3226 (Renesas Electronics Corporation, Tokyo, Japan), a high-performance integrated circuit specifically designed for inductive position sensing applications [17]. This device features high-speed operation, built-in excitation for the transmitter coil, and dual demodulation channels for the receiver windings. This application-specific integrated circuit (ASIC) is capable of supporting dual-receiver configurations, both Coarse-Fine and Vernier, with up to 32 periods; the 1- and 16-period configuration is, therefore, one of the possible choices. With this configuration, the resolution of the sensor is .
In addition to this ASIC, a microcontroller was integrated into the design. This decision was made to ensure maximum flexibility. In fact, while the RAA2P3226 requires programming for proper operation, it outputs the calculated angle through specific native protocols, such as UART (Universal Asynchronous Receiver-Transmitter), ABI (A/B/Index incremental encoder interface), Step/Dir, or I2C (Inter-Integrated Circuit). Adding a microcontroller enables efficient communication with the RAA2P3226 and simplifies the implementation of external interfaces based on more robust industrial protocols (CAN, Modbus, SSI…). In addition, the presence of an onboard microcontroller enables the development of internal control and processing functions that use the sensor’s angular data, transforming the device from a passive component into an intelligent node within more complex systems.
For the sake of design simplicity, this prototype was designed to transmit data from the sensor via the USB protocol, with a communication frequency for the calculated angle of 1 kHz.
The entire system is powered by 5 V supplied directly from the USB connection. An LDO provides the 3.3 V required to power the microcontroller and the ASIC. The sensor draws approximately 70 mA from the external 5 V power supply.
Figure 6 shows a block diagram illustrating the sensor’s internal architecture.
Figure 6.
Block diagram of the sensor’s internal architecture.
Figure 7.
Assembled stator PCB Top side (a) and Bot side (b).
Figure 8.
Target PCB Top side (a) and Bot side (b).
Table 2 presents an estimate of the bill-of-materials cost of a single sensor for batches of 10, 100 and 1000 units, based on quotes from component distributors and PCB manufacturers. The cost of the housing, of the assembly and of the commercial wind vane is not included. These numbers are indicative of the order of magnitude; a quantitative cost comparison with other technologies is beyond the scope of this work.
Table 2.
Estimated cost per sensor for different batch sizes.
2.3. Mechanical Structure of the Sensor
Turning to the mechanical structure, a housing was designed to contain the sensor and ensure stability during operation. Figure 9 shows an exploded view of the entire structure, highlighting the following components in order:
Figure 9.
Exploded view of the complete sensor assembly.
- Adapter for the motorized rotation stage located beneath the sensor;
- Manual linear stage, necessary for aligning the motorized rotation stage and the sensor, the use of which is detailed in the following section;
- Housing accommodating the stator of the rotary sensor;
- Stator of the inductive sensor;
- Target of the inductive sensor;
- 3D-printed adapter for the target;
- NKE hub/shaft (ref. SF000424) [18];
- 3D-printed adapter for the NKE shaft;
- NKE weathervane cone (ref. CP002537) [19];
- NKE wind vane blade (ref. CP002559) [20].
The sensor’s rotating target was mechanically coupled to a commercial wind vane assembly [21]. Rather than designing a fully custom mechanical interface optimized for this specific sensor, off-the-shelf marine-grade components were adopted to evaluate the sensor’s ability to be integrated with existing, widely deployed mechanical hardware.
This is consistent with the scope of this work, which focuses primarily on proposing a different technology for sensor deployment in the marine environment, rather than on the design of a fully optimized system.
Further details regarding the mechanical assembly are provided below:
- Parts 1 and 3 are made of poly(methyl methacrylate) (PMMA) and were milled with a computer numerical control (CNC) milling machine GP Proto CNC-GP010 Series (Crespellano, Italy), with a tolerance of ±0.02 mm [22];
- Parts 6 and 8 were 3D-printed in PETG-CF with a Bambu Lab H2D Pro printer (Shenzhen, China), whose XY motion accuracy with the Vision Encoder is specified as <50 m [23];
- Although the NKE hub/shaft ends with a magnet—designed for use with magnetic sensors—the target adapter spaces the magnet away from the stator portion of the inductive sensor, thereby minimizing any interference it might cause.
The 3D-printed PETG-CF parts and the PMMA housing are intended for the prototype only; a final product would use marine-grade polymers or potting, and the PCBs would be protected by conformal coating or potting.
3. Experimental Tests
3.1. Setup Description
Before presenting the conducted tests, the measurement setup is described.
To ensure controlled rotation, the entire system is driven by a Zolix TBR200 motorized rotation stage (Zolix Instruments Co., Ltd., Beijing, China) [24], whose most relevant parameters are listed in Table 3.
Table 3.
Zolix TBR200 motor’s positioning parameters [24].
The system described above functions correctly only if the motor’s center of rotation precisely coincides with the center of the sensor. If this condition is not met, the center of the sensor traces an orbit around the motor’s rotation center, adding a nonlinear systematic error (Figure 10).
Figure 10.
Illustration of the alignment of the axes of rotation: axes not aligned (a), axes aligned (b).
The sensor centering process involves rotating the motor while monitoring the position of the stator’s housing (part 3 of Figure 9) using a Mitutoyo 575-121 m [25] positioned perpendicular to the axis of rotation, as illustrated in Figure 11. By adjusting the manual linear stages placed between the motor and the sensor, it is possible to finely calibrate the sensor’s position until the instrument detects no relative displacement during a full rotation of the motor. Since the micrometer has a resolution of 0.01 mm and accuracy of 0.02 mm, minor misalignments could not be calibrated.
Figure 11.
Illustration of the alignment procedure.
It is important to note that the centering process is necessary exclusively to ensure a metrologically correct measurement. The sensor consists of blocks 3–10 shown in Figure 9, excluding the linear stages and the motor, which are used solely for testing.
It should be noted that any relative misalignments between the stator and target are not taken into account in this calibration and are due solely to the manufacturing tolerances mentioned in the previous section.
Now that the sensor has been aligned with the motor, three tests were conducted to validate its performance: static, semi-static, and dynamic.
The three tests address different aspects. In the static test, the vane is locked, there is no wind, and the stage imposes known angles: it characterizes the sensor alone (accuracy, repeatability, hysteresis). In the semi-static test, the complete assembly is exposed to a steady airflow with the vane free to rotate, and the stage holds the stator at fixed angles; the measurement is taken at steady state for each position, so the test evaluates the accuracy of the assembly under steady wind, not a change of wind direction. The dynamic test, on the other hand, evaluates the transient response to a change of wind direction (step response), which is the parameter used to qualify wind vanes.
3.2. Static Test
The purpose of this test is to measure the sensor’s accuracy and repeatability, which are critical for validating the proposed technology. During this test, the wind vane was locked in place, and a known reference angle was imposed by controlling the TBR200 motor.
The test was conducted according to the following procedure:
- Zero is set at the reading of the inductive sensor;
- A reading from the sensor is saved. It should be noted that no averaging was performed; only a single sample is taken per reading;
- The motor is rotated clockwise by ;
- Steps 2 and 3 are repeated until is reached;
- Another measurement sweep is performed, but this time the motor’s direction of rotation is reversed, proceeding from to ;
- Steps 1 through 5 are then repeated 10 times in succession, resulting in 10 clockwise sweeps and 10 counterclockwise sweeps. This allows us to evaluate the sensor’s hysteresis error.
3.3. Semi-Static Test
A wind tunnel was used to expose the sensor to a controlled airflow at 3, 6, 9, 12, 15 and 18 m/s, measured with an Extech SDL310 [26] (Figure 12). For each speed, the stage rotated the stator to 12 angular positions (, , …, ), always in the CW direction. For each angular position, 10,000 samples at 1 kHz were acquired and their mean and standard deviation were computed with circular statistics. The vane was free to align with the flow, so that the imposed angle equals the stage angle. The zero was set at the reading of the sensor.
Figure 12.
Measurement setup for semi-static and dynamic tests.
The sampling rate is the output rate of the sensor and is about two orders of magnitude higher than the highest oscillation frequency of the vane (about 11 Hz, Section 4.3), while 10,000 samples (10 s) cover tens of oscillation periods of the vane, making the mean and the standard deviation stable.
The error is the difference between the mean reading and the imposed angle.
It is worth noting that the wind tunnel used is normally dedicated to aircraft engine testing; its flow is not laminar, and turbulence intensity and flow uniformity in the test section were not characterized. As real marine wind is also turbulent, the test provides a realistic functional validation of the complete assembly rather than a calibrated characterization of the vane.
The standard deviations reported in Section 4.2, therefore, include the effect of flow unsteadiness.
3.4. Dynamic Test
The purpose of this test is to verify the sensor’s response to a change in wind direction.
To mimic real-world conditions, the same setup illustrated in Figure 12 was used. During this evaluation, the wind vane was initially held perpendicular to the wind direction and subsequently released, recording the system’s dynamic behavior until steady-state conditions were achieved. The wind speed was varied across a range from a minimum of 3 m/s up to 18 m/s, with steps of 3 m/s.
Figure 13 depicts a schematic diagram illustrating the test procedure.
Figure 13.
Dynamic test setup: initial position (a), final position (b).
4. Analysis of the Results
This section presents the results of the tests described in Section 3, analyzing them to understand the performance of the sensor proposed in this paper.
4.1. Static Results
As described in Section 3.2, a total of 20 measurements were collected, 10 of which were in a clockwise direction and 10 in a counterclockwise direction. Each of these measurements consists of 360 data points, one per degree.
Once all the data had been collected, the error—defined as the difference between the measured angle and the reference angle set using the TBR200 stage—was evaluated. This resulted in 20 error values for each angle under evaluation.
The plot in Figure 14 shows the mean of these 20 error values for each angle, along with their standard deviation, which is necessary for evaluating repeatability.
Figure 14.
Static test results: mean error ±1 of 20 sweeps.
The first point to note is that the mean error is confined to the range from − to (within ± when the ± band is included). It should be emphasized that this value also includes the positioning accuracy of the TBR200 rotary stage (Table 3). The maximum standard deviation of the error, on the other hand, is .
Considering that this test isolates the sensor from the rest of the mechanical system, this result demonstrates the substantial potential of inductive technology.
Figure 15 shows an FFT analysis of the data just analyzed, in order to obtain more information regarding the cause of the error.
Figure 15.
Spectral analysis of the static error curve shown in Figure 14. The red dashed line indicates the 16 cycles/revolution coil pitch.
The FFT was computed on the mean error as a function of the mechanical angle over one revolution (360 points, one per degree), so the spectrum is expressed in cycles per revolution. The fundamental frequency is, therefore, 1 cycle/revolution (period of ), which is also the frequency resolution, and the maximum resolvable frequency is 180 cycles/revolution.
It can be observed that the largest contribution comes from the 1–2 cycle/revolution component. In the RAA2P3226 chip used to calculate the angle, the 1-period receiver is used solely to determine the sector of the 16-period receiver, on which the error characteristics then depend. Since the error does not depend on a single period, the low-frequency contribution is consistent not so much with an intrinsic error in the coil design as with residual misalignments between the stator and target.
Further supporting this argument is the fact that, around the frequency of 16 cycles/revolution (dashed in red), a broadening of the spectrum is observed. This is again attributable to a modulation of the coupling between the transmitter and the 16-period receiver, which manifests as marked contributions at the frequencies of .
One possible source of error is the residual eccentricity from the calibration described at the beginning of Section 3 (Figure 10). Since the wind vane is held steady by its tail during the static test, any residual eccentricity causes an intrinsic measurement error. Considering a maximum eccentricity equal to the accuracy of the Mitutoyo 575-121 m [25] (0.02 mm) and the length of the wind vane (approximately 90 mm), the variation in the actual applied angle results . This type of error is low-frequency and should be considered one of the possible observable low-frequency contributions. Figure 16 shows the hysteresis analysis, where the top graph displays the averages of the 10 measurements in the clockwise (blue) and counterclockwise (orange) directions. The lower graph, on the other hand, shows the hysteresis, i.e., the CCW-CW difference.
Figure 16.
Static test hysteresis: clockwise and counterclockwise mean error curves (top); hysteresis, CCW−CW (bottom).
The first observation is that the 16-cycle-per-revolution component is absent, indicating that this contribution—due to the design of the 16-period receivers—is independent of the direction and tends to cancel itself out. The remaining contribution appears as a low-frequency component (1–2 cycles per revolution) associated with mechanical misalignment. This contribution is consistent with mechanical clearances present in the various couplings, such as the backlash of the TBR200 motor and the NKE shaft bearing.
Table 4 summarizes the main results of the static analysis of the sensor.
Table 4.
Results of the static test.
4.2. Semi-Static Results
As described in Section 3.3, during this test the wind vane was allowed to move freely, and an artificial wind was generated using a wind tunnel. For each measurement position, 10,000 samples were collected, for which the mean and standard deviation were calculated. This test measures the mechanical-aerodynamic behavior of the wind vane and its coupling with the sensor target.
Table 5.
Semi-static results (from 3 up to 9 m/s).
Table 6.
Semi-static results (from 12 up to 18 m/s).
An initial analysis can be performed by plotting the trends of the standard deviation for each acquisition angle and the mean error for each wind speed (Figure 17). Note that “error” here refers to the difference between the mean calculated for each position and the angle imposed by the rotation stage.
Figure 17.
Semi-static test results: standard deviation of the measured angle as a function of wind speed, one curve per acquisition angle (a); mean angular error as a function of acquisition angle, one curve per wind speed (b).
In addition, Table 7 presents a summary showing the key values to be discussed.
Table 7.
Summary of key values of the semi-static test.
For wind speeds of 6 m/s and above, the standard deviation tends to plateau, while the mean error is more repeatable. Below 6 m/s, however, the mean error exhibits outliers and is typically negative. This behavior is consistent with the aerodynamic torque at 3 m/s being comparable to the mechanical friction of the vane. Since the angle sweep was always performed in an increasing direction, friction tends to hold the vane at an angle smaller than the reference, which would explain the prevalently negative error. Further support comes from the decrease in the error between 3 and 6 m/s, as expected if the aerodynamic torque grows with speed. A direct quantification of the friction torque would require the aerodynamic coefficients of the vane and is left to future work. Above 6 m/s, however, the aerodynamic torque overpowers the frictional forces, forcing the wind vane into a better alignment and thus resulting in a smaller and more repeatable error.
Regarding the standard deviation at 6 m/s and above, since the vane is free to rotate, it follows the fluctuations of the flow direction, so the observed dispersion (about 1–) is most likely due to the unsteadiness of the tunnel flow, possibly including vortex shedding from upstream bodies. As the flow was not characterized, the individual contributions cannot be separated. At 3 m/s, conversely, the standard deviation is much lower (below ), consistent with the vane being held by friction, as discussed above.
Consequently, the system’s accuracy is largely governed by the mechanical coupling between the wind vane and the sensor rather than by the sensor itself: the errors observed in this semi-static test are larger than those measured for the sensor in isolation (Section 4.1); in particular, the standard deviation of the sensor alone is at most , almost two orders of magnitude below the dispersion measured in the tunnel, indicating that the sensor’s angular measurement capability is not the limiting factor in the current configuration. To evaluate the performance of the system built, a comparison can be made directly with the specifications of the NKE sensor that uses this type of wind vane [21]. The stated accuracy and activation threshold are and 1 m/s, respectively. Although the results obtained in this semi-static test are worse, considering that this system is an adaptation of the NKE wind vane and that the specifications of the commercially available sensor were obtained through tests with laminar and finely controlled wind, the system we built proves to be comparable.
4.3. Dynamic Results
Figure 18 shows the sensor’s step responses as wind speed varies.
Figure 18.
Dynamic test results at different wind speeds: (a) 3 m/s, (b) 6 m/s, (c) 9 m/s, (d) 12 m/s, (e) 15 m/s, (f) 18 m/s.
As expected, the system exhibits an underdamped second-order response at all six wind speeds.
We will now proceed with a more detailed analysis of the performance metrics to understand the quality of the sensor. Refs. [27,28] were used as a reference for the subsequent analyses.
A first parameter to analyze is the percentage overshoot of each response, defined as the amplitude of the first transient peak that exceeds the steady-state value, expressed as a percentage of the input step amplitude.
where:
- is the amplitude of the first peak;
- is the steady-state value, which in this discussion has been calculated as the average of the values after the dynamic was completed;
- is the input step amplitude, calculated as .
The damping ratio , on the other hand, quantifies the effectiveness of viscous forces in damping the wind vane’s oscillations. It is derived directly from the percentage overshoot as follows:
where is the percentage overshoot.
A key point to note is the linear relationship between the system’s damped frequency f and wind speed U. The damped frequency is calculated based on the time interval between the first two maximum peaks.
Calculating this for all tested wind speeds yields the following:
A linear regression shows that the ratio is approximately 0.627 Hz/(m/s). The linearity of this trend, shown in Figure 19, indicates that within the tested range, mechanical friction forces do not appear to significantly affect the damped frequency.
Figure 19.
Damped oscillation frequency (f) as a function of the wind speed (U).
It is important to note that this result does not contradict what was stated in Section 4.2, as the types of tests are different. While in the semi-static test the wind vane starts out almost completely aligned with the wind direction (and thus at a low angle of attack), in the dynamic test under consideration the wind vane is perpendicular to the wind’s motion, and, therefore, at a maximum angle of attack. In the semi-static case, the force exerted by the wind becomes dominant over the bearing’s friction forces only at speeds of 6 m/s and above, whereas in the dynamic test, the force exerted by the wind is sufficient to overcome the nonlinear friction forces as early as 3 m/s.
Table 8 presents the numerical results obtained from the data analysis.
Table 8.
Summary of the dynamic parameters across the tested wind speeds.
These results can be compared with the state of the art to better understand the performance and quality of the prototype that was built.
The calculated damping ratio (mean 0.284, range 0.25–0.32) is slightly below the value specified in the Guide to Instruments and Methods of Observation (Annex 1A, Table 5.2 of the WMO Guide) [27]. Since the damping ratio depends on the geometry and inertia of the vane (e.g., its area and arm length) and not on the sensor, reaching would require a custom vane design. Other high-end wind direction sensors report values that are in the same order of magnitude as the one calculated from the dynamic tests, for example:
- Met One Instruments 020 Wind Direction Sensor features a certified damping ratio between 0.25 and 0.4 [29].
- R.M. Young Wind Monitor Model 05103-10A reports a damping ratio of 0.3 and a damped wavelength of 7.4 m [30].
At the conclusion of this analysis, it can, therefore, be stated that the wind vane’s mechanical system has been successfully integrated into the sensor assembly, demonstrating the flexibility of inductive technology in adapting to existing solutions.
5. Discussion
The static test, characterizing the sensor alone under rigid coupling, showed a maximum error within ± (including the ≤ accuracy of the stage), with a maximum standard deviation of and a hysteresis up to . The dominant error component is at 1–2 cycles/revolution. Since the 1-period channel only selects the sector of the fine period, and electrical errors of the 16-period channel appear at multiples of its electrical frequency, this component is consistent with a mechanical origin (residual eccentricity or tilt between stator and target); the positioning accuracy of the stage may also contribute, and the two contributions cannot be separated in this test.
The low-frequency error is mostly repeatable: its peak values (about ±) are several times larger than the repeatability of the sensor. A software compensation is, therefore, feasible, provided that the mechanical misalignment is stable in time. Since the dominant components are at 1–2 cycles/revolution, a correction based on a few harmonics, or on a look-up table, can be implemented in the microcontroller already present on the board, with calibration points acquired against a reference more accurate than the target accuracy. The residual error would be limited by the repeatability and the hysteresis of the sensor, and noise could be further reduced by filtering, since the output rate (1 kHz) is much higher than the bandwidth of the vane. As the offset between stator and target depends on the manufacturing tolerances of each unit, in mass production the parameters would be determined by an end-of-line calibration. For the application considered, however, a calibration may not be needed: the uncompensated error of the sensor (±) is about 4% of the error of the assembled prototype (±) and about 8% of the declared for the commercial NKE unit, so the accuracy of the assembly is not limited by the sensor misalignment.
The semi-static and dynamic tests characterized the complete system, including the NKE carbon wind vane. At wind speeds of 6 m/s and above, the mean error is within approximately ±, with a standard deviation of about 1–2∘ that is most likely due to the unsteadiness of the tunnel flow, which was not characterized. Since the static error of the sensor is within ±, with a standard deviation of at most , the accuracy of the assembly is limited by the vane and its mechanical coupling, and not by the sensor. At 3 m/s, the larger and predominantly negative error is consistent with an aerodynamic torque comparable to the friction of the vane, whose quantification would require the aerodynamic coefficients of the vane. The error is larger than the declared for the commercial NKE sensor, but of the same order of magnitude.
The dynamic response is underdamped at all speeds, yielding a damping ratio between 0.25 and 0.32 (mean 0.284), a damped frequency proportional to the wind speed (0.627 Hz/(m/s)) and a damped wavelength of about 1.6 m. The damping ratio is slightly below the value of the WMO Guide [27], but within the 0.25–0.4 range of the Met One 020 [29] and close to 0.3 of the R.M. Young 05103 [30]. The shorter wavelength compared with the 7.4 m of the R.M. Young is consistent with the smaller size and lower inertia of the vane used. The sensor can, therefore, be coupled to existing marine-grade hardware, with a dynamic response of the same order as that of commercial wind vanes.
As regards the design, the stacked layout keeps a footprint of 43 mm, compared with the diameter of about 10 cm of a side-by-side Coarse-Fine design [12], at the cost of requiring the mutual independence of the two receivers and a small air gap. Variations in the gap due to vibrations, bearing play and thermal expansion mainly reduce the signal-to-noise ratio. Simulations show that the peak voltage induced on the receiver decreases from 50 mV at the nominal gap (0.5 mm) to 40 mV at +0.1 mm and 35 mV at +0.2 mm, i.e., a reduction of 20% and 30%, corresponding to a signal-to-noise ratio loss of about 1.9 dB and 3.1 dB, respectively, for a constant noise level. A reduction in the gap, conversely, increases the induced voltage and, therefore, the signal-to-noise ratio, so the only critical case is the mechanical contact between stator and target, which would occur only if the nominal gap of 0.5 mm were completely lost. Since the angle is computed from the ratio of the two demodulated signals, a change in the gap that affects them equally mainly degrades the noise and not the accuracy.
As regards power, the prototype draws about 70 mA from the 5 V supply (about 350 mW), including the ASIC, the microcontroller and the linear regulator. The consumption could be reduced with a switching regulator or a direct 3.3 V supply. The output rate of 1 kHz is also about two orders of magnitude higher than the highest oscillation frequency of the vane (about 11 Hz), so a lower rate or a duty-cycled operation could further reduce the consumption of a battery-powered unit.
Future work will involve custom designs for the wind vane, with the aim of improving its response even to winds below 3 m/s, and adding an anemometer to the system that would allow for the measurement of wind speed in addition to wind direction. Environmental robustness (temperature, humidity, salt spray, fog, UV exposure) and immunity to external electromagnetic fields were not evaluated experimentally: no aging, immersion, salt spray, thermal cycling, vibration or electromagnetic compatibility tests were performed. The suitability of the sensor for marine environments is, therefore, based on the physical properties inherent to the inductive sensing principle and on the literature, and the verification of its long-term reliability under marine conditions is left to future work.
6. Conclusions
This paper presented a stacked-coil inductive position sensor for wind direction measurement, based on a Coarse-Fine architecture with 1- and 16-period receivers on a 43 mm PCB, less than half the diameter of side-by-side Coarse-Fine designs (about 10 cm [12]). The sensor alone agrees with the reference stage within ± (including the stage accuracy), with a maximum standard deviation of and a hysteresis up to . Coupled to a commercial vane, the mean error is within approximately ± at 6 m/s and above and the step response is underdamped with between 0.25 and 0.32. This error is of the same order as that of the commercial unit and is much larger than the sensor’s own contribution; vane, mechanical coupling and the uncharacterized tunnel flow dominate it. Environmental robustness and immunity to electromagnetic fields were not evaluated experimentally: the suitability for marine environments is based on the physical properties inherent to the inductive principle, and the verification of long-term reliability is left to future work.
Author Contributions
Conceptualization, A.A., L.C., F.T. and R.S.; software, R.S.; validation, J.F., A.A. and L.C.; formal analysis, J.F., A.A. and L.C.; investigation, J.F., A.A., L.C. and F.T.; data curation, J.F., A.A., L.C. and F.T.; writing—original draft, J.F. All authors have read and agreed to the published version of the manuscript.
Funding
Funded under the 2021/2027 European Social Fund Plus (ESF+) Regional Programme of the Autonomous Region Friuli Venezia Giulia, Specific Programme No. 20/24, CUP G23C25000620008.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The data presented in this study are openly available in Zenodo at https://doi.org/10.5281/zenodo.23492543.
Acknowledgments
The authors would like to thank Marco Gentile for his technical support regarding the mechanical setup. Specifically, his contribution pertained to the Resources section, where he performed the milling and 3D printing of the sensor housing to secure the sensor to the motor during testing.
Conflicts of Interest
Author Ruben Specogna is a founder and shareholder of the company EMC Gems Srl. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| ABI | A/B/Index incremental encoder interface |
| ASIC | Application-Specific Integrated Circuit |
| CAN | Controller Area Network |
| CFD | Computational Fluid Dynamics |
| CNC | Computer Numerical Control |
| I2C | Inter-Integrated Circuit |
| IPS | Inductive Position Sensor |
| LDO | Low-Dropout (voltage regulator) |
| PCB | Printed Circuit Board |
| PETG-CF | Polyethylene Terephthalate Glycol-Modified reinforced with Carbon Fiber |
| PMMA | Poly(methyl methacrylate) |
| PP | Prepreg |
| RX | Receiver |
| SSI | Synchronous Serial Interface |
| Std | Standard deviation |
| TX | Transmitter |
| UART | Universal Asynchronous Receiver–Transmitter |
| US | Ultrasonic Sensor |
| USB | Universal Serial Bus |
| C | Microcontroller |
References
- Neal, M.; Sauzé, C.; Thomas, B.; Alves, J.C. Technologies for autonomous sailing: Wings and wind sensors. In Proceedings of the 2nd International Robotic Sailing Conference (IRSC), Matosinhos, Portugal, 6–12 July 2009; pp. 6–12. [Google Scholar]
- Müller, M.; Götting, M.; Peetz, T.; Vahs, M.; Wings, E. An Intelligent Assistance System for Controlling Wind-Assisted Ship Propulsion Systems. In Proceedings of the 2019 IEEE 17th International Conference on Industrial Informatics (INDIN), Helsinki, Finland, 22–25 July 2019; pp. 795–802. [Google Scholar] [CrossRef] [Scilit]
- Nelissen, D.; Faber, J.; Köhler, J.; Mao, W.; Traut, M.; Ahdour, S. Study on the Analysis of Market Potentials and Market Barriers for Wind Propulsion Technologies for Ships; CE Delft: Delft, The Netherlands, 2016; ISBN 978-92-79-64629-4. [Google Scholar]
- Fernandes, D.; Gomes, L.; Costa, A. Wind speed and direction measurement based on time of flight ultrasonic anemometer. In Proceedings of the 2017 IEEE 26th International Symposium on Industrial Electronics (ISIE), Edinburgh, UK, 19–21 June 2017; pp. 1417–1422. [Google Scholar] [CrossRef] [Scilit]
- Shan, Z.; Xie, X.; Liu, X. Wind Speed and Direction Measurement Based on Three Mutually Transmitting Ultrasonic Sensors. IEEE Geosci. Remote Sens. Lett. 2023, 20, 8000205. [Google Scholar] [CrossRef] [Scilit]
- Yang, J.; Li, Y.; Jiang, J.; Liu, Q. Development of a High-Accuracy Ultrasonic Wind Measurement Instrument With Shadow Effect Correction. IEEE Trans. Instrum. Meas. 2026, 75, 9518311. [Google Scholar] [CrossRef] [Scilit]
- Ripka, P.; Blažek, J.; Mirzaei, M.; Lipovský, P.; Šmelko, M.; Draganová, K. Inductive Position and Speed Sensors. Sensors 2020, 20, 65. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Datlinger, C.; Hirz, M. Benchmark of Rotor Position Sensor Technologies for Application in Automotive Electric Drive Trains. Electronics 2020, 9, 1063. [Google Scholar] [CrossRef] [Scilit]
- Brajon, B.; Lugani, L.; Close, G. Hybrid Magnetic–Inductive Angular Sensor with 360∘ Range and Stray-Field Immunity. Sensors 2022, 22, 2153. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kuntz, S.; Gerlach, G.; Fella, S. Inductive Position Sensors based on Coupling of Coils on Printed Circuit Boards for Demanding Automotive Applications. arXiv 2025, arXiv:2503.14627. [Google Scholar]
- Kumar, A.S.A.; George, B.; Mukhopadhyay, S.C. Technologies and Applications of Angle Sensors: A Review. IEEE Sens. J. 2021, 21, 7195–7206. [Google Scholar] [CrossRef] [Scilit]
- FLUX GmbH. IND-ROT Series—Absolute Inductive Rotary Encoder Technical Datasheet; FLUX GmbH Document Repository; FLUX GmbH: Braunau am Inn, Austria, 2023; Available online: https://flux.gmbh/Datasheets/INDUCTIVE-ROTARY-Encoders-Datasheet-web.pdf (accessed on 20 September 2026).
- IEC 60945:2002; Maritime Navigation and Radiocommunication Equipment and Systems—General Requirements—Methods of Testing and Required Test Results. IEC: Geneva, Switzerland, 2002.
- IEC 60068-2-52:2018; Environmental Testing—Part 2-52: Tests—Test Kb: Salt Mist, Cyclic (Sodium Chloride Solution). IEC: Geneva, Switzerland, 2018.
- IPS Magic. Inductive Position Sensor Simulator. Available online: https://ipsmagic.cloud (accessed on 2 October 2026).
- Kuntz, S.; Gerber, D.; Gerlach, G.; Fella, S. Design and Analysis of Receiver Coils with Multiple In-Series Windings for Inductive Eddy Current Angle Position Sensors Based on Coupling of Coils on Printed Circuit Boards. Sensors 2024, 24, 4880. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Renesas Electronics Corporation. RAA2P3226 Datasheet; Renesas Electronics Corporation: Tokyo, Japan, 2025; Available online: https://www.renesas.com/en/document/dst/raa2p3226-datasheet (accessed on 21 July 2026).
- NKE. Hub/Shaft/Magnet Anemometer. Available online: https://en.comptoirnautique.com/instrument-nke/9033-nke-hub-shaft-magnet-anemometer.html (accessed on 7 September 2026).
- NKE. Universal Weathervane Cone. Available online: https://en.comptoirnautique.com/instrument-nke/68251-nke-universal-weathervane-cone.html (accessed on 7 September 2026).
- NKE. Carbon Wind Vane Blade. Available online: https://en.comptoirnautique.com/instrument-nke/68249-nke-carbon-wind-vane-blade.html (accessed on 7 September 2026).
- NKE. Masthead Unit CARBOWIND HR Datasheet. Available online: https://www.nkeitalia.it/wp-content/uploads/2016/06/Manuale_Carbowind_ENG.pdf (accessed on 7 September 2026).
- GP Proto CNC. GP010-1000 L 630 × 1000 × 140 Pantografo CNC. Available online: https://www.gp-protocnc.it/gp010-1000-l-630-x-1000-x-140/ (accessed on 21 September 2026).
- Bambu Lab. Bambu Lab H2D Pro Product Page. Available online: https://bambulab.com/it-it/h2d-pro (accessed on 21 September 2026).
- Zolix Instruments Co., Ltd. TBR and TBRF Series Motorized Rotational Stages Datasheet. Available online: https://www.zolix.com.cn/filespath/files/Motion%20Control/MotorizedStages-en/TBR%20and%20TBRF.pdf (accessed on 4 August 2026).
- Mitutoyo America Corporation. Mitutoyo Catalog No. E1003. Available online: https://www.mitutoyo.com/Images/CatalogUS-1003/resources/_pdfs_/US-1003_Catalog_252.pdf (accessed on 4 August 2026).
- Extech Instruments. SDL310 Vane Thermo-Anemometer/Datalogger Datasheet; Extech Instruments: San Diego, CA, USA, 2010; Available online: https://calright.com/wp-content/uploads/2018/02/24403.pdf (accessed on 5 August 2026).
- WMO. Guide to Instruments and Methods of Observation (WMO-No. 8); World Meteorological Organization: Geneva, Switzerland, 2024; Available online: https://community.wmo.int/site/knowledge-hub/programmes-and-initiatives/instruments-and-methods-of-observation-programme-imop/guide-instruments-and-methods-of-observation-wmo-no-8-0 (accessed on 19 September 2026).
- EPA. Meteorological Monitoring Guidance for Regulatory Modeling Applications; Office of Air Quality Planning and Standards: Research Triangle Park, NC, USA, 2000. Available online: https://www.epa.gov/sites/default/files/2020-10/documents/mmgrma_0.pdf (accessed on 19 September 2026).
- Met One. 020 Wind Direction Sensor Datasheet. Available online: https://metone.com/wp-content/uploads/2026/06/010C-020-Wind-Speed-Sensor-Data-Sheet-06162026.pdf (accessed on 19 September 2026).
- R.M. Young Company. Wind Monitor MODEL 05103-10A Datasheet; R.M. Young Company: Traverse City, MI, USA, 2000; Available online: https://www.youngusa.com/wp-content/uploads/2025/06/05103-10A-90I.pdf (accessed on 19 September 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.


















