Skip to Content
SensorsSensors
  • Review
  • Open Access

17 June 2026

18 Pages

Analytical Validation of Low-Cost Optical Sensors for Freshwater Monitoring: A Scoping Review of Current Gaps and a Proposed Framework

,
,
,
,
,
,
,
,
and
1
Department of Earth and Marine Sciences, University of Palermo, Via Archirafi 22, 90123 Palermo, Italy
2
Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy
3
Center for Colloids and Surface Science (CSGI)-Siena Research Group, University of Florence, Via Della Lastruccia 3, 50019 Firenze, Italy
4
Earthwatch Europe, 102–104 St. Aldate’s, Oxford OX1 1BT, UK
This article belongs to the Special Issue Sensor Technologies for Environmental Monitoring

Abstract

Low-cost optical sensors have emerged as promising tools for in situ freshwater quality monitoring, offering the potential to expand spatial and temporal data coverage, particularly in community-based monitoring projects. However, despite rapid technological development of low-cost optical sensors, analytical validation practices of these devices remain poorly studied. This study aims to systematically and critically assess analytical validation practices applied to low-cost optical sensors based on absorbance, fluorescence, colorimetry, and light scattering, potentially designed for community-based freshwater monitoring. A total of 40 studies were analysed to evaluate how key analytical performance parameters, including sensitivity, accuracy, precision, and repeatability, as well as comparison with reference methods or benchtop instruments, were assessed and reported in relation to established validation guidelines. The analysis revealed substantial heterogeneity and critical gaps in validation approaches. While most studies report sensitivity metrics such as limits of detection and quantification, comprehensive evaluation of key analytical parameters such as accuracy, precision, and reproducibility was often limited. The reliance on single calibration experiments and high determination coefficients (R2) frequently overestimates sensor performance. The lack of open-source materials further limits reproducibility and deployment: essential information such as design files, calibration procedures, and open-source resources is often incomplete or unavailable. To address these limitations, we propose a structured framework for validation and reporting that integrates established analytical guidelines with the practicalities of low-cost sensor development. Adoption of this approach would enable more consistent performance evaluation, improving reproducibility and facilitating comparison across studies and devices. Overall, strengthening analytical validation and reporting practices is essential to support the transition of low-cost optical sensors from proof-of-concept systems to reliable analytical devices for freshwater quality monitoring.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.