Skip to Content
SensorsSensors
  • Article
  • Open Access

8 January 2025

43 Pages

Structural Fatigue Life Monitoring with Piezoelectric-Based Sensors: Fundamentals, Current Advances, and Future Directions

,
and
Microlab, Faculty of Civil Engineering and Geosciences, Delft University of Technology, 2628 CD Delft, The Netherlands
*
Author to whom correspondence should be addressed.

Abstract

Structural fatigue can lead to catastrophic failures in various engineering applications and must be properly monitored and effectively managed. This paper provides a state-of-the-art review of recent developments in structural fatigue monitoring using piezoelectric-based sensors. Compared to alternative sensing technologies, piezoelectric sensors offer distinct advantages, including compact size, lightweight design, low cost, flexible formats, and high sensitivity to dynamic loads. The paper reviews the working principles and recent advancements in passive piezoelectric-based sensors, such as acoustic emission wave and strain measurements, and active piezoelectric-based sensors, including ultrasonic wave and dynamic characteristic measurements. These measurements, captured under in-service dynamic strain, can be correlated to the remaining structural fatigue life. Case studies are presented, highlighting applications of fatigue life monitoring in metals, polymeric composites, and reinforced concrete structures. The paper concludes by identifying challenges and opportunities for advancing piezoelectric-based sensors for fatigue life monitoring in engineering structures.

1. Introduction

Fatigue life monitoring (FLM) is crucial for safety critical structures, such as buildings, bridges, aircraft, and pavements, where failure due to cyclic or dynamic loads could lead to catastrophic consequences [1]. For example, around 85% of failures in metallic structures are caused due to fatigue [2]. FLM must be conducted using appropriate sensing technologies to assess the remaining lifespan of these structures, ensuring their safe operation and preventing downtime. These structures are made from various materials, including metals, fiber-reinforced composites, and reinforced concrete, each exhibiting unique fatigue-induced damage. As such, tailored approaches are required for the effective FLM and mitigation of fatigue failure. For example, in isotropic materials such as metals, the primary form of fatigue damage is the initiation and propagation of cracks [3] due to corrosion and loads. Microscopic cracks, often initiated at stress concentration points, can progressively grow with cyclic loading, leading to a decline in structural integrity. For fiber-reinforced composites, fatigue damage is mainly characterized by matrix cracking, delamination, and fiber breakage [4]. Matrix cracking occurs within the resin or matrix, compromising the composite’s load-bearing capacity. Delamination, the separation of layers, can result from repeated cyclic stresses, and fiber breakage can occur as the reinforcing fibers experience fatigue loading. In reinforced concrete structures, fatigue-induced damage encompasses microcracks, carbonation, chloride-induced corrosion, and delamination, leading to the initiation and propagation of larger cracks [5].
As shown in Figure 1, different fatigue-induced damage mechanisms can compromise the structural durability of structures over time. Despite the different damage mechanisms, three different stages can be identified in fatigue failure: (i) damage initiation, (ii) stable damage propagation, and (iii) unstable damage propagation. FLM aims to detect the damage in stages I and II (see Figure 1), before it becomes critical. Failure to prevent fatigue failure can result in disasters, and examples are shown in Figure 2, where structures made of different materials failed suddenly, resulting in the loss of lives and high costs consequences.
Figure 1. Fatigue-induced damage mechanisms in different engineering materials. (a) Damage evolution of a titanium alloy [6], (b) damage evolution in fiber-reinforced concrete [7], and (c) damage evolution of a polymer composite [8].
Figure 2. Examples of disastrous events caused by fatigue failure. (a) De Havilland comet plane crashes, metallic materials, 1954. (b) A highway bridge collapses, reinforced concrete, 2018. (c) Titan vessel crashes, fiber-reinforced composite, 2023.
There is a significant industrial demand for cost-effective and reliable FLM solutions to ensure safety, reliability, and longer service life. The current technology typically employs a range of sensors, including strain gauges, piezoelectric, electrical resistance, electromagnetic, and optical sensors, to measure parameters such as vibration, strain, load, and the size or shape of damage. These data can then be processed to detect changes and to identify patterns that are indicative of the remaining fatigue life of the structures, and can help in serviceability assessment and maintenance planning for structures [9].
Among the sensing techniques applied, piezoelectric-based sensors have been used widely for SHM purposes [10,11,12,13,14,15], due to their distinct advantages, including compact size, lightweight design, cost-effectiveness, flexible formats, a wide frequency range, high sensitivity to dynamic loads, and durability [16,17]. A fast dynamic response with high sensitivity, negligible decay, high fatigue life, and robustness under operational conditions characterizes them [18].
Piezoelectric-based sensors operate based on the piezoelectric effect, which is observed in certain materials, such as the ones shown in Figure 3. Lead zirconate titanate (PZT) and electroactive polymers like polyvinylidene fluoride (PVDF) are the most widely used materials. PZT is most employed in sensors and actuators due to its excellent piezoelectric properties (Figure 3). Although PVDF has lower piezoelectric coefficients than PZT, it stands out for its lightweight nature, flexibility, chemical resistance, and ease of processing [13]. Piezoelectric materials generate an electric charge when exposed to mechanical stress or pressure (see Figure 4) [19,20]. This property enables their use in various sensing techniques, including passive methods like the acoustic emission technique [10], and active methods such as the vibroacoustic modulation technique and the piezoelectric impedance method [21]. A detailed overview of the latest developments in piezoelectric materials and sensors for SHM is provided in a recent publication [22]. Several other review articles also discuss the application of piezoelectric sensors in SHM [16,19,20,23,24]. These reviews cover various applications, including polymer–matrix composites [21,25], aircraft [26], wind turbine blades [27,28,29], bridges [30], and other engineering structures [31].
Figure 3. Comparison of the piezoelectric coefficient in different types of piezoelectric materials [32].
Figure 4. The piezoelectric sensor’s working principle under compression.
This review paper provides an overview of the piezoelectric-based sensors for FLM.

2. Piezoelectric Sensor’s Application in FLM

Figure 5 shows different piezoelectric-based sensors that are used in FLM. These sensors can be categorized as passive and active. Active methods include ultrasonic testing (UT) techniques, such as vibroacoustic modulation, which employs piezoelectric materials for Lamb wave generation and detection, and the electro-mechanical impedance (EMI) technique, which utilizes high-frequency structural excitation and impedance response monitoring. Passive methods include acoustic emission (AE) and strain gauge mode (STG) measurement techniques. These piezoelectric-based sensors monitor various parameters influencing fatigue life, such as crack or defect initiation, size, location, and dynamic strain history. Figure 6 illustrates the percentage utilization of piezoelectric-based sensors across active and passive methods for FLM among the papers reviewed in this research. UT is the most frequently used method, followed by AE, EMI, and strain measurement.
Figure 5. Comparative analysis of FLM techniques employing piezoelectric sensors.
Figure 6. The proportion of piezoelectric sensor types used for FLM in the reviewed papers.
The following provides an overview of recent research on FLM using piezoelectric sensors, highlighting advantages, limitations, and categorized details of each study, including materials and methods, summarized in tables at the end of each section.

2.1. FLM Using UT

UT-based crack detection is a commonly used technique for different types of materials [33,34]. It involves transmitting and receiving ultrasonic waves (from several tens of Hz to 1.5 MHz) to detect changes caused by cracks or defects [35]. The waves travel through the material and are reflected encountering a crack or defect. The reflected waves are then picked up by the same (pulse–echo method) or a different sensor (pitch–catch method), and their amplitude and time delay are measured [35], as depicted in Figure 7. The pitch–catch method utilizes low-frequency-guided Lamb waves (usually around 5 kHz to 100 kHz), which are effective for surface and subsurface defect detection due to their propagation characteristics and are less influenced by microstructural variations. However, this approach demands precise alignment and a complex positioning system. Additionally, analyzing the results can be challenging due to the multimodal and dispersive nature of low-frequency waves. In contrast, the pulse–echo method employs high-frequency waves, which are simpler to set up, requiring only a single sensor for transmission and reception. This method is cost-effective and easier to implement, but it demands a high voltage excitation and significant averaging to achieve a good signal-to-noise ratio and is more susceptible to interference from microstructural details and surface roughness. Both methods can detect transverse cracks and monitor their growth. The choice between these methods depends on the specific inspection needs, such as the type and location of defects, material thickness, and practical considerations like setup complexity and cost [36,37]. The ability of UT-based methods to detect cracks has been extensively reported in the literature. However, the sensitivity and accuracy of these methods depend significantly on various factors, including the type of structure, crack geometry, and the characteristics of the propagating wave. For instance, it has been demonstrated that cracks as small as 0.5 mm in length can be detected [38]. In another experimental setup utilizing the nonlinear features of Lamb waves, even smaller cracks with a length of just 1.35 μm were successfully identified [39].
Figure 7. A simple demonstration of the UT NDT method principle in the pitch–catch mode.
Ihn and Chang [40,41] developed and validated a piezoelectric-based diagnostic technique for monitoring fatigue crack growth in metallic aircraft structures. Utilizing ultrasonic-guided Lamb waves, the method enhances sensor measurements and maximizes the signal-to-noise ratio for accurate damage detection. A physics-based damage index was used to correlate sensor data with crack growth size. Validation tests on notched aluminum plates and riveted fuselage joints demonstrated a strong correlation between the damage index and actual crack growth observed visually and using eddy current testing. These findings confirm the technique’s potential for accurate and reliable crack growth monitoring in complex structural applications, where cracks/debondings as small as 5 mm can be detected in riveted joints and composite repairs. In this research, Equations (1) and (2) were used to calculate damage index (DI) for critical crack length and deboned detection. S0 (symmetric zero-order) waves have symmetric particle motion and higher phase velocity, making them suitable for detecting subsurface and internal cracks. A0 (antisymmetric zero-order) waves exhibit antisymmetric motion, i.e., a lower phase velocity, and are sensitive to surface cracks and delamination [42].
In another study, Mi et al. [43,44,45] demonstrated the development and validation of an advanced ultrasonic method for the in situ monitoring of fatigue crack initiation and growth in aluminum specimens, specifically those with rivets and fastener holes. As shown in Figure 8, the method utilizes permanently mounted miniature angle beam sensors to detect changes in ultrasonic wave energy caused by the crack formation and modulated by the applied load. Two self-calibrating techniques were introduced: one compensating for sensor degradation using pulse–echo signals and the other using a normalized energy ratio of loaded to unloaded conditions, with the latter proving more effective for direct crack interaction measurement [43]. A “dynamic” measurement technique was also developed, allowing continuous monitoring during fatigue tests without interruption. This dynamic method accurately estimates uniaxial loads and correlates well with static measurements, demonstrating its effectiveness in tracking crack progression by modulating ultrasonic wave energy during load-induced crack opening and closing [44,45]. Theoretical analysis showed that the observed time shifts can be explained by changes in path due to elastic deformation and acoustoelastic effects. Further research is suggested to quantitatively assess these methods and determine tolerance levels for sensor and coupling degradation.
D I C r a c k   d e t e c t i o n = S c a t t e r e d   e n e r g y   o f   S 0   w a v e B a s e l i n e   e n e r g y   o f   S 0   w a v e  
D I D e b o n d   d e t e c t i o n = S c a t t e r e d   e n e r g y   o f   A 0   w a v e B a s e l i n e   e n e r g y   o f   A 0   w a v e    
Figure 8. Schematic of the position of the UT sensors placed on the Al specimen.
S. Gupta et al. [46,47,48], represented a real-time fatigue monitoring technique based on symbolic time series analysis (STSA) of UT data in an aluminum specimen. The optical images were captured every 200 cycles to investigate the uniformity distribution, and an analytical study of STSA for the obtained UT data, the anomaly profile, and the crack’s length were conducted. In order to analyze and process the UT data and investigate crack properties, P. Rizzo et al. [49] analyzed the fatigue crack process (crack initiation and propagation) of a steel beam, using a PZT sensor and actuator to emit and detect the ultrasonic-guided wave (UGW). An unsupervised machine learning algorithm and discrete wavelet transform (DWT) were utilized to probe the fatigue crack process and to calculate the DI. They concluded that the optimum testing frequency for the first anti-symmetric propagation mode was 225 kHz.
Experimental and finite element analyses were performed by C. Zhou et al. [50] for fatigue crack detection using nonlinear features of UT travelling waves. The authors used a network of permanently integrated active PZT sensors on an aluminum plate for quantitative crack monitoring. After the study on the influence of cracks on nonlinear features of UT waves, they developed a probability-based diagnostic imaging algorithm to visualize the results.
H. Cho and C. Lissenden [51] presented experimental and analytical research on fatigue crack monitoring in aluminum plates using UT. They used PZT discs as sensors to transmit and receive UT Lamb waves in the vicinity of fastener holes. They concluded that the transmission coefficient of propagated waves can be studied to detect and locate the fatigue crack. By comparing the transmitted wave amplitude before and after crack initiation, they achieved an FLM method in plate structures. Z. Su et al. [52] used UT wave features generated by four PZT sensors in the pulse–echo and pitch–catch modes for the quantitative evaluation of the fatigue DI in metallic plates. Comparing linear and nonlinear features of waves such as TOF and energy, they revealed that the nonlinear features of UT waves have a higher sensitivity than the linear features and it is more effective to detect small-scale fatigue cracks using nonlinear features. Figure 9 schematically shows the advantage of using UT’s nonlinear features, where the nonlinear measurements can detect much smaller fatigue-induced cracks/damage, and therefore provide timely information for effective maintenance and repair purposes. They also developed a probabilistic-based diagnostic imaging algorithm to show the crack’s location and size.
Figure 9. Comparison of linear and nonlinear UT measurements in FLM.
M. Hong et al. [53] conducted a theoretical model investigation for early damage detection using the nonlinearity features of UT. The modelling technique was developed to comprehend material, geometric, plasticity-driven, and contact acoustic nonlinearities that contributed to the nonlinear distortion of UT wave propagation. H. Chan et al. [54] evaluated the developed model in an experiment to monitor the fatigue crack around the fastener hole in a multi-layer aerospace 6061 aluminum plate using PZT sensors with high-frequency UGWs in the pulse–echo mode. A piezoelectric sensor was used to propagate and receive the Lamb wave. A non-contact laser measurement was also applied to evaluate the influence of fatigue crack in the aluminum layer on the Lamb wave scattering. They confirmed the feasibility of identifying concealed fatigue cracks in the second layer from a distance, without requiring access to the damaged specimen’s side, using a standard ultrasonic pulse–echo apparatus. P. Liu et al. [55] developed a wireless sensor node to monitor the fatigue crack using UT. They used two PZT discs to send two discrete high and low frequencies and received them by one PZT disc. Then, using the Discrete Fourier Transform (DFT) and considering the influence of occurred damage on the nonlinearity response of UT data, they investigated the statistical parameters “Skewness” and “Median” of the nonlinear index (NI). According to the NI, it was possible to detect the early-stage fatigue cracks without relying on any historical data of the target structure. In another study, M. Haile et al. [56] presented an analytical model using UT data to estimate fatigue crack growth in rotorcraft aerospace-grade aluminum structure and compared it with two industrial models, Paris–Erdogan and NASGRO. It was reported that the prediction error of the UT-based model was reduced by 50% compared to the two commonly used industry models.
A structural fatigue life prediction using Lamb waves was presented by D. Wang et al. [57], which focused on developing and validating data-driven models for crack quantification by experiments on coupon samples and lap joint tests. This study investigated the intricate relationship between model complexity, goodness of fit, probability of detection (POD) performance, and reliability in Lamb wave-based crack quantification for fatigue life prediction. The evaluation includes a nuanced consideration of the impact of the model choice on fatigue life prediction, emphasizing the need for a careful balance between model complexity and reliability in FLM. T. Jiang et al. [58] monitored fatigue damage in modular bridge expansion joints (MBEJs) in real time using PZTs. The approach involves analyzing the stress waves generated by the PZT sensor actuator and received by the PZT sensor. The experimental results showed that the amplitudes and wavelet packet energies of the signals received by the PZT sensor decreased as fatigue damage occurred. The proposed method can accurately detect the fatigue damage degree of any full-penetration weld in real time and has the potential to identify the initial fatigue damage occurrence in MBEJs. The authors verified the reliability and sensitivity of the proposed method using additional full-scale CB/SB assembly specimens with different fatigue loads. H. Jin et al. [59] introduced a reliable method to monitor fatigue cracks in SMA490BW steel plate-like structures using UGWs and various acoustic features. The proposed technique provides a hybrid DI by the fusion of DIs calculated using different acoustic features, such as amplitude-based and energy-based DIs in the time–frequency domain. The results demonstrated that the fused DIs calculated by the acoustic features in the frequency domain are more reliable than those in the time domain. Specifically, the linear and differential amplitude fusion DIs in the frequency domain are more promising to quantitatively indicate the propagation of fatigue cracks than other fused ones.
To improve the fatigue crack diagnosis (FCD) using guided waves (GWs), L. Xu et al. [60] used convolutional neural networks (CNNs) for signal processing to address the influence of dispersion on reliable FCD in real-world engineering applications. Using piezoelectric sensors to construct an input feature vector, the authors extracted multiple DIs from multiple GW exciting acquisition channels. A CNN was then designed to further extract high-level features from the multiple DIs and implement feature fusion for crack evaluation. The proposed method was validated through fatigue tests on a typical aircraft structure and showed promising results in reducing the influence of uncertainties on FCD. The lowest diagnostic accuracy achieved was 86.84%, with a diagnostic error of 1 mm. The authors also conducted comparative experiments that demonstrate the proposed method’s superior diagnostic robustness and accuracy compared to traditional methods. In another study [61], a new framework was proposed for quantitative evaluation and continuous monitoring of non-penetrating fatigue cracks in structures using a piezoelectric sensor. The framework consisted of a two-step process. In the first step, a 3D analytical model based on the theory of elastodynamics was used to generate contact acoustic nonlinearity in UGWs under the modulation of a non-penetrating fatigue crack, resulting in a crack-area-dependent nonlinear DI. In the second step, the 3D fatigue cracks growth model predicted the continuous growth of the identified fatigue crack in length and depth along the crack front. The framework was validated using numerical simulation and experiments, with the continuous prediction of the crack growth in length and depth. The results demonstrated the accuracy and precision of the developed modelling framework for characterizing propagating fatigue damage in real-life structures. The paper addressed the significance of characterizing and monitoring 3D, non-penetrating fatigue cracks at different stages of propagation, which are often simplified to two-dimensional models, risking evaluation accuracy.
Lamb waves that were actuated by piezoelectric sensors for fatigue crack detection and monitoring were also used to develop a two-dimensional cross-correlation imaging technique by W. Xiao et al. [62]. The imaging method is based on the cross-correlation algorithm that uses incident waves and crack-scattered waves of all directions to generate the crack image. The presented imaging method successfully inspects and quantifies the crack length and its growth. The use of scattered waves of all directions has the advantage of containing more information about the fatigue crack regarding the overall dimension of the crack. The frequency–wavenumber filtering method was utilized to extract the incident waves and the scattered waves. A scanning laser Doppler vibrometer was adopted for acquiring a time–space multidimensional wave field, followed by frequency–wavenumber processing. The proof-of-concept study was conducted on an aluminum plate with a hairline fatigue crack, and then, the imaging method was applied for crack growth monitoring on a stainless-steel plate undergoing fatigue loading. The paper suggested that the imaging method presented has the potential to be extended to different structural materials and more complex defects with highly irregular profiles. In another study, a new method for detecting and monitoring the growth of fatigue-induced cracks in welds was proposed by D. Zhou et al. [63] using piezoceramic sensors and coda wave interferometry (CWI). A theoretical model based on the acoustoelastic effect and CWI theory established a linear relationship between the crack width change and the relative velocity variation of coda waves. The authors conducted experiments using the CWI method to detect micro-fatigue cracks in three butt welded specimens under fatigue loading. The results showed that the relative velocity variation of coda waves increases linearly with the increase in the width of fatigue cracks. The CWI method was more sensitive to slight changes in welding fatigue cracks compared to the energy-based active sensing approach using a swept sine wave. The paper concluded by demonstrating the feasibility of the CWI method to monitor the slight variations in weld fatigue crack growth.
X. Zeng et al. [64] proposed an online updating strategy to accurately predict the propagation of fatigue cracks in an aircraft wing. The strategy combined an adaptively tunable hybrid radial basis function network and active Lamb wave-based SHM to capture the dynamic characteristics of piezoelectric sensor signals and predict the varying tendency of crack growth. The methodology employed a hybrid spatial-phase difference-based DI to quantify the crack length and deal with uncertainties during the prognosis of fatigue cracking propagation. The study validated the proposed method through fatigue tests on the outboard wing of a real airplane, demonstrating the effectiveness of the DIs method in mapping the varying tendencies of crack growth. The results showed that the posterior estimation of the crack length using the proposed methodology provides fewer measurement errors than the calculated values by the damage mechanics method. The proposed methodology has the potential to be expanded to other airframe structures and even the whole airframe. However, the early prognosis of crack growth results in errors and oscillations, which can be reduced by establishing a comprehensive model and a more effective DI method and real-life data collection as the focus of future research.
In another study, H. Lee et al. [65] developed a robust automatic damage diagnosis technique using UT Lamb waves and a deep auto-encoder (DAE) model that can accurately detect and classify fatigue damage in composite structures. The authors installed PZT sensors on carbon fiber-reinforced polymer (CFRP) composite plates to monitor fatigue damage evolution from matrix cracking to delamination. The collected UT signals were then used to train the DAE model, which effectively tracked UT response variations and diagnosed fatigue damage in the composite specimens. To enhance the accuracy and sensitivity of damage detection, the architecture and hyperparameters of the DAE model were optimized, and a statistical detection baseline was defined to capture damage indicators. The results demonstrated that the proposed technique can accurately detect and classify fatigue damage modes in a CFRP composite plate. It eliminated the need for manual or signal processing-based damage-sensitive feature extraction from UT signals for damage diagnosis. R. Nobile et al. [66] conducted an experimental investigation for monitoring the evolution of fatigue damage in carbon fabric open-hole specimens using UT measurements. The study showed that the UT signals acquired in wave packets with pitch–catch mode during the different phases of the fatigue life can be evaluated and correlated to the applied loads. The examination of the UT data revealed a high sensitivity of the UT signal to stiffness decrease and fatigue damage associated with delamination near the hole. Additionally, the consolidated pulse–echo phased array technique was used to evaluate the state of damage concerning the degradation of the signal detected with the PZT sensors. The results demonstrated the potential capability of the applied experimental technique for the real-time detection of delamination on composite elements subjected to time-varying loads. Furthermore, the study successfully applied an experimental procedure based on the UT propagation of Lamb waves to monitor in real time the onset and the progressive evolution of the damage up to failure.
To identify and quantify fatigue cracks in a steel joint under vibration conditions, Yu Lee and Ye Lu [67] utilized nonlinear GWs based on the second harmonic generation and piezoelectric sensors to excite the S1 Lamb wave mode in experiments. The contact acoustic nonlinearity was measured in experiments and quantified by a nonlinear index to evaluate fatigue crack. The study also involved a simulation using finite element analysis to verify the experimental results, and the outcomes were found to be in good agreement. The researchers proposed a percent reduction in nonlinearity as a measure to evaluate the crack length based on the difference of nonlinear index measured at static and vibration conditions. The results showed that the percentage reduction in nonlinearity increased with crack growth. The conclusion was that the proposed method is promising for fatigue crack identification and quantification based on second harmonic generation under practical working conditions of structures. However, further research is required to examine the exact contact area distribution between crack surfaces under the influence of applied vibration forces. In addition, for damage localization of complex structures, the nonlinearity caused due to ambient conditions, such as temperature and humidity variations, should be considered. An experimental investigation into the Lamb wave-based FLM of aluminum bolted joints with multiple sites was presented by C. Chen et al. [68]. The signals before and after the initiation of the fatigue cracks were compared to calculate the DI, which served as an indicator to map the fatigue crack size. The phase shifts between the baseline signal before the fatigue crack existence and the signal with fatigue cracks resulted in an overestimated DI. To solve this problem, the envelope damage index (EDI) was introduced to monitor fatigue cracks. The envelope curves of the baseline signal and the signal with fatigue cracks were considered in the calculation of EDI. The results showed that EDI is a better parameter than DI for monitoring the fatigue crack size and location in the aluminum bolted joints with multiple-site fatigue damage. The authors also validated the group velocity and time of flight for the S0 mode and the A0 mode and observed that fatigue cracks occur in hot spot areas. In the case of cracks in the vicinity of fastener holes in aircraft structures, V. Wong et al. [69] proposed a novel approach for detecting fatigue cracks, using direct-write piezoelectric UT sensors. These sensors were designed with an annular array of electrodes surrounding the fastener hole and made of PVDF piezoelectric material. The sensors could operate in both pulse–echo and pitch–catch techniques and could detect Lamb wave modes at a frequency of 1.5 MHz. The authors conducted numerical simulations and experimental testing to investigate the UT wave propagation and interaction with the defect. They used wavelet analysis and the energy ratio method to quantify the extent of the fatigue cracks. The results showed that the pulse–echo method could determine the direction of the fatigue crack, while the pitch–catch method had a higher sensitivity in crack detection but could not determine the crack direction. The direct-write UT sensors with annular array electrodes have a small footprint, lower cost, and compact size, making them suitable for the in situ SHM of fastener holes. Recently, X. Li et al. [70] presented a method for measuring surface cracks using Rayleigh waves and PVDF piezoelectric film UT sensor array (Figure 10). The method employed a delay-and-sum algorithm to enhance the detected Rayleigh wave signals and determine the depth of surface fatigue cracks. The proposed method was compared with Rayleigh wave detection using a Rayleigh wave receiver made of piezoelectric ceramic and a laser interferometer. The results showed that the low-profile PVDF film transducer array was more effective due to its low attenuation of surface-sensitive Rayleigh waves. The proposed method was suitable for monitoring crack initiation and early-stage propagation and is applicable to measure cracks present in complex structures such as welded joints. The crack depth monitoring procedure was successfully demonstrated by measuring fatigue cracks induced at two welded joints of a 38 mm thick steel cruciform structure under a cyclic mechanical loading test. The results indicated that the proposed method using a PVDF film UT sensor array is efficient and cost-effective compared to the laser interferometer and bulky piezoelectric ceramic Rayleigh wave receiver arrays. Table 1 presents a comprehensive overview of the literature, highlighting applications, monitoring strategies, and materials monitored using UT for FLM.
Figure 10. Schematic illustration of the system for monitoring the depth of a surface crack on a structure with Rayleigh waves [70].
Table 1. Detailed and categorized descriptions of the research in the field of FLM using UT waves.

2.2. FLM Using AE

AE is a passive non-destructive method that is used for the in situ SHM of engineering structures [71]. AE detects high-frequency acoustic signals generated by the release of energy from the material under stress (from several kHz to several hundred Hz) [72]. These signals can be detected using specialized AE sensors that convert the acoustic energy into electrical signals that can be analyzed and interpreted. The signals detected by AE sensors can be analyzed to determine the location and severity of damage in the structure. AE can also be used to monitor the progression of damage over time, as the signals generated by the release of energy from the material change as the size and shape of the damage evolves [73]. The AE technique is widely used for the detection and monitoring of fatigue cracks in metallic and composite structures. It is a sensitive and reliable method for detecting the onset of damage, as it can detect cracks that are too small to be visible using traditional inspection techniques, such as visual inspection or UT. But some limitations need to be addressed, such as environmental noises that originate from sources such as strong winds, passers-by, and trucks driving on nearby streets. These noise signals can be effectively mitigated by employing a bandpass filter [74]. Also AE signal propagation attenuation dependency on propagation distance limits this technique [75]. Since AE is affected by environmental noises, a false positive detection is likely which can be listed in the limitation list [76,77]. In AE testing, sensors are typically placed on the surface of the structure being monitored or embedded within the material itself (Figure 11). When the material undergoes stress or deformation, such as from a load or thermal expansion, the release of energy generates high-frequency acoustic waves that propagate through the material and can be detected by the piezoelectric AE sensors [78]. For example, Figure 12 shows the work by M. Saeedifar et al. [79] to determine the crack tip position during propagation of mode I delamination in glass/epoxy composite specimens. AE testing is considered a qualitative monitoring method, as it is difficult to quantify the damage level due to limitations such as the non-repeatable nature of the AE signals, sensitivity to noise, and the difficulty of interpreting complex signal patterns. Therefore, only very basic indicators, typically based on thresholds set on characteristic quantities of interest, are applied that can provide an estimate of the general condition, without detailed quantification of the extent of damage or damage topology. Although this offers some rough information, it should be improved to offer more quantitative information for monitoring purposes.
Figure 11. (a) A simple sketch of the AE experimental setup, and (b) a schematic of an AE waveform [80].
Figure 12. (a) The AE event localization procedures. (b) Prediction of fatigue-induced delamination size in laminated composites by AE [79].
AE was used to monitor the health state of a flexible riser by T. Clarke et al. [81,82]. This riser contains several protective layers as well as helical wires in external armor. They measured strain over the wires using fiber Bragg grating was successfully used to validate the effectiveness of the AE sensor used on the riser circumference. When comparing the results from these two methods, they tried to relate the AE data to wire ruptures and load measurement. D. Gagar et al. [83] utilized AE to investigate the influence of fatigue loading and sample geometry on AE during crack growth in aluminum specimens. They studied the fatigue crack propagation and crack length by monitoring the change in AE Hit rates. Also, the location and length of the crack were investigated based on the AE event’s distribution. In another study, fatigue monitoring, using AE through PZT sensors, was conducted by M. Pearson et al. [84]. Three mapping techniques, time of arrival (TOA), Delta-t, and Akaike information criterion (AIC) Delta-t, were evaluated to estimate the fatigue damage location. Table 2 reports the average error of different techniques used for the source location, where the AIC Delta-t provided the most accurate estimation. They reported that using the AIC Delta-t mapping for locating damage in an SHM system would allow for the confident and more probable detection of damage irrespective of the threshold used.
Table 2. Summary of the average Euclidean error in the source location [84].
AE monitoring and Bayesian estimation were used to detect and localize fatigue damage in girth-welded steel pipes by M. Shamsudin et al. [85]. The authors found a strong correlation between the AE energy and the estimated coefficients, which helped identify pipe cracks. The proposed method can potentially be used as an additional tool to increase confidence in source localization in AE testing and for monitoring crack growth in extreme conditions. The study highlighted the usefulness of AE monitoring for evaluating the condition of piping to manage the risk of vibration-induced fatigue failure. The study suggested further studies to validate the approach on a broader range of structural components and under various loading conditions.
Post-processing and the informative assessment of AE signals were conducted by J. Garrett et al. [86] to investigate the correlation between fatigue crack length and AE signal signatures. An automated AE waveform analysis technique was suggested using artificial intelligence methodologies, finite element analysis, and experimental investigation to capture and characterize AE waveforms. The experimental data were used with a CNN to build a system capable of predicting the length of the fatigue crack with an accuracy of 98.4%. The paper concluded that the proposed approach could be extrapolated to similar applications beyond binary crack length prediction and suggests that further experimentation with other crack lengths will be valuable in constructing a comprehensive crack monitoring system. In a recent study [87], the performance of piezoelectric patch acoustic sensors was compared to conventional AE sensors for detecting damage and leakage. The findings validate the potential of piezo for passive AE sensing, supporting their role as a complement to their well-established application in active sensing. Table 3 provides a detailed overview of the applications of AE for FLM in the literature.
Table 3. Detailed and categorized descriptions of the research in the field of FLM AE.

2.3. FLM Using UT Waves and AE

A combination of AE and UT methods can also be used for FLM and detect associated damage and cracks. The two methods differ in their sensitivity and accuracy. AE is more sensitive to microcracks and is better suited for detecting early stages of damage [88], where the crack length is small and not detectable by UT, as schematically shown earlier in Figure 9, while UT testing is more accurate in determining the size and location of cracks [89]. Grondel et al. [90] conducted research to compare the result of the detection of cracks propagation in aluminum strap joint plates using a UT sensor and Lamb wave propagation, and AE method. X-ray images were also used to validate the AE and UT results, reflecting a good agreement between the AE and UT. M. Gresil et al. [91] simulated GW and AE for fatigue crack monitoring in a thick steel plate, and were able to calculate the DI and crack dimensions by taking advantage of the numerical method and wavelet-based signal processing. H. Mei et al. [92] utilized piezoelectric wafer active sensors (PWAS) as AE sensors for in situ AE detection during fatigue crack growth. The time of arrival of AE signals at multiple sensors confirmed the origin of the AE signals from the crack, and the amplitude decay of the AE signals was validated. J. Etxaniz et al. [93] developed an SHM Ultrasound System (SHMUS) that is capable of implementing both passive (AE) and active (UT) strategies to monitor structures for various types of damage, including sudden and progressive damages caused by impacts, fiber breakages, corrosion, delamination, and fatigue. The authors validated the SHMUS effectiveness on both metallic and composite structures and analyzed the effects of sudden and progressive damages on the integrity of the structures. The results showed that the SHMUS not only detected impacts and damages but also measured the structural integrity degradation and the damage increases in size. This developed SHMUS prototype was suggested for potential use in the aeronautical industry, as it can help monitor the integrity of aircraft structures throughout their entire life cycle. Table 4 provides a detailed overview of the applications of AE and UT hybrid systems for FLM in the literature.
Table 4. Detailed and categorized descriptions of the research in the field of FLM using UT waves and AE.

2.4. EMI Measurements for FLM

The EMI technique, originally introduced by Liang et al. [94], has been widely investigated for FLM. This method uses a piezoelectric sensor to excite the host structure while simultaneously recording the structural response. The sensor’s electrical admittance, which is the inverse of its impedance, is directly correlated with the mechanical impedance of the structure. As a result, changes in structural properties can be identified by monitoring variations in the sensor’s electrical impedance [95]. As shown in Figure 13, in EMI, a small alternating current, typically in the frequency range of kHz to MHz, is applied to the sensor. Subsequently, the resulting voltage, which is proportional to the sensor’s impedance, is measured [96]. EMI sensors can be strategically positioned at critical points on the structure to continuously track changes over time. The initiation and growth of small cracks cause measurable variations in the sensors’ impedance, enabling the assessment of the structure’s remaining fatigue life [19].
Figure 13. The underlying principle of the EMI method [97].
Soh and Lim [98] demonstrated the potential of using the EMI technique with surface-mounted PZT patches for detecting and characterizing fatigue damage in an aluminum beam. In a similar study, Li et al. [99] employed the EMI method for the real-time monitoring of fatigue crack initiation and propagation in an aluminum specimen. Their findings highlighted EMI’s high sensitivity to early-stage damage, successfully capturing the entire process of crack initiation, propagation, and unstable fracture under fatigue loading.
In another study, Giurgiutiu et al. [100] successfully demonstrated the pitch–catch approach to record the arrival time of the Lamb wave and EMI measurement at a higher frequency under fatigue loading, for crack growth detection in an Arcan steel. S. Bhalla et al. [101] used the equivalent stiffness identified by surface-bonded PZT patches, to quantify fatigue-induced damage in bolted steel joints and to predict the remaining useful life of the component. They conducted a comprehensive study on the effect of the host structure’s stiffness on PZT’s admittance. In this regard, they investigated the root mean square of the real part of PZT’s admittance (admittance (Y) = conductance(G) + j Susceptance (B)), as defined in Equation (3). Where R e Y i is the real part of the electromechanical admittance of the PZT patch at any stage during the test, R e Y i 0 is the baseline value (in pristine condition), and ‘ i ’ represents the frequency index. The fatigue life was related to the equivalent stiffness and the remaining life correlated to the number of loading cycles.
R M S D = ∑ i = 1 N R e Y i − R e Y i 0 2 ∑ i = 1 N R e Z Y i 0 2
M. Haq et al. [102] used two embedded PZT sensors to detect mechanical movements and evaluate the fatigue life of a reinforced concrete column. The concrete column exerted cyclic vibration by a shake table, and then, a fast Fourier transform was applied to find and investigate the natural frequency of concrete column vibration. The results showed the natural frequency of the column was directly related to the structure’s stiffness and the natural frequency was decreased by increasing the damage. S. Bahalla and N. Kaur [5] used embedded piezoelectric sensors for monitoring low-strain fatigue-induced damage in reinforced concrete structures. The method involved piezo-based composite concrete vibration sensors (CVSs) embedded inside the beam near the surface, operating in the global and local modes. The experimental study demonstrated that the proposed method is effective in detecting and localizing fatigue-induced damage, and in predicting the remaining service life of the RC structure. The equivalent stiffness identified by the CVS in the EMI mode correlates well with the stiffness in the first and third regions of the fatigue S-N curve, making it suitable for detecting fatigue initiation and predicting final failure.
M. Haq et al. [103] utilized PZT-impedance sensors to monitor fatigue damage and assess the residual life of reinforced concrete frames, embedding PZT patches as actuators and sensors, and combining the EMI technique with global dynamic methods. Admittance signatures were acquired using six piezo-cement composite disks embedded at different locations in the structure. DWT, continuous wavelet transformation (CWT), and power spectral density analysis were applied to identify, localize, and estimate the severity of the damage. The proposed method was effective in diagnosing high-cycle and low-strain fatigue damage in reinforced concrete structures and is validated for all three phases of the fatigue life span of the structure. The rate of CVS-identified stiffness loss obtained after measuring equivalent stiffness parameters was found to be comparable in high-frequency fatigue loads, constituting 1.03 times higher stiffness change rate as obtained using actual flexural stiffness values of the RC structure.
In another study, life prediction models were proposed based on the residual stiffness, damping. and wavelet energy approach [104]. The DWT-based optimum methodology provided superior performance in enabling a real-time damage prognosis of reinforced concrete structures under low-strain and high-cycle fatigue. Two mathematical models were proposed for estimating the remaining useful life of reinforced concrete frames based on the equivalent flexural stiffness of the frame and the equivalent wavelet transform of the energy of conductance signatures. The study established the potential of the wavelet transform energy drawn using DWT signal processing techniques for characterizing damage and identifying the vicinity of beam-column joints as a critical area for fatigue failure. The method was found to be satisfactory in establishing a life-prediction model for the structure for any fatigue phase, which can be used to develop better collapse-alarming systems and prolong the structural life by retrofitting it to the appropriate location.
M. Haq et al. [105] proposed a novel application of wavelet to transform the energy of piezo-impedance signatures in monitoring the premature fatigue damage of reinforced concrete frames. The study included the implementation of the EMI technique combined with DWT on frequency domain PZT-admittance signatures to identify, localize, and quantify the severity of premature fatigue damages. The authors successfully developed residual-life predicting models based on EMI-identified equivalent structural damping and DWT-based wavelet energies in initial and severe stages to the deboning initiation. Additionally, the authors introduced an economical impedance-based solution using a miniature AD5933 chipset to monitor premature damages in externally retrofitted reinforced concrete structures. The proposed system can be further developed to create online wired or wireless monitoring systems utilizing different PZT forms for proposing electro-mechanical models for predicting the remaining life of different kinds of structures.
L. Ali et al. [106] used the EMI technique and finite element analysis for monitoring fatigue cracks in T-type joints of offshore steel jacket structures. The study highlighted the successful application of the EMI for the fatigue monitoring of the joints. Table 5 provides a detailed overview of the applications of EMI measurements using piezoelectric sensors for FLM in the literature.
Table 5. Detailed and categorized descriptions of the research in the field of FLM using the piezoelectric sensor for EMI.

2.5. Strain Gauge Mode for FLM

Piezoelectric sensors can be used as passive strain gauges for FLM by assessing the strains within a structure [107]. The strain measurement principle is based on the conversion of mechanical strain into an electrical charge by the piezoelectric sensor, thereby facilitating the measurement of dynamic strains over time which are responsible for fatigue failure [108]. Previous studies showed that there is a direct correlation between the strain level and voltage generated by piezoelectric sensors [107,109]. Figure 14 indicates the FLM principle using the strain monitoring concept, where the strain variation measurements (the severity and occurrence frequency) are used to measure the stress history of the material. The stress profile is then connected with the S-N curves, obtained from laboratory experiments, to evaluate the remaining life of the structure.
Figure 14. Strain profile measurement and its link with the S-N curves, considering the variation in the applied stress and frequency of the stress.
Aulakh and Bhalla [110,111] assessed the use of PZT patches for EMA-based structural identification and damage monitoring in a 2D rectangular steel plate. They found that strain modal parameters provided more sensitive damage features compared to accelerometer-based modal parameters, especially for detecting early-stage damage. In another study [18], piezo sensors were evaluated for modal identification of a pedestrian footbridge subjected to pedestrian motions, with results compared to accelerometer-based displacement modal parameters. The piezo sensors effectively captured low-amplitude dynamic strain responses, and strain modal testing showed a strong correlation with conventional acceleration testing. This approach was applied to real-life footbridges, where piezo sensors successfully detected bending and torsion modes, demonstrating high repeatability and minimal deviation.
Y. Zhang [112] used a paintable piezoelectric sensor to develop a method for measuring the surface crack on a metallic cantilever beam. The sensor was printed on the structure and was used to detect the crack(s) by comparing the electrodes’ output signal. The generated voltage was related to the DI by Equation (4), where x 1 t and x 2 ( t ) are the measured voltage signals from each of the electrode pairs of the printed piezoelectric sensor, and RMS denotes the root mean square value of the measured voltage signal.
D a m a g e   I n d e x = x 1 t − x 2 ( t ) R M S ( x 1 t + R M S ( x 2 ( t ) ) 2                                                                                  
N. Lajnef et al. [113] proposed a new approach by a combination of piezoelectricity and metal–oxide semiconductor (MOS) technology to make a self-powered and wireless sensor node for strain and temperature monitoring on pavements. They investigated MOS field effect transistors (MOSFETs) with floating gat to achieve a passive memory cell and to relate electrical parameters to temperature variation. They also studied the effect of traffic wander on fatigue life prediction.
A. Alavi et al. [114] represented distortion-induced fatigue crack detection methods in steel bridge girders, using a self-powered piezo-floating-gate sensor array. Piezoelectric sensors harvest the mechanical energy of crack displacement, and the generated energy is stored cumulatively to show the amount of crack displacement. Reading all floating gate cells in an array made it possible to localize the crack and its length. To determine the fatigue life, the J-integral concept and Paris Law were used. The results indicated that the proposed method is capable of detecting different damage progression states.
D. Kim et al. [115] utilized PVDF film sensors for fatigue damage monitoring of single-lap adhesive joints. The results showed that the PVDF film sensor exhibited constant sensitivity in terms of voltage per load, and the amplitude of the voltage signal increased as the maximum fatigue load increased. The applicability of the PVDF film sensor for fatigue damage monitoring was successfully demonstrated.
Other studies [116,117] used a piezoelectric strain sensor to measure the fatigue life of airframe structures, by measuring the crack closure, and the piezoelectric sensor outperformed traditional extensometers and back-face strain gauges in accuracy and consistency. The sensor reduced measurement scatter by at least 100%, with improvements nearing 200% under challenging conditions.
A. Ghaderiaram et al. [108] introduced an implementation strategy for using PZT in bending mode to measure strain, involving a 3D-printed extension bonded to the structure’s surface with epoxy glue. This extension offers several advantages, including the conversion of structural strain to PZT’s bending chord, preventing sensor rupture in high strain levels, and facilitating the measurement of one-dimensional strain due to the magnified voltage of PZT in bending compared to tension. Figure 15a illustrates the extension, featuring two legs that define the initial bending and a flexible sensor bed for sensor attachment. It also shows two built-in cases for LVDT installation, designed for sensor calibration. The preliminary results, presented in Figure 15b, demonstrate a linear relationship between the generated voltage and strain. As the tensile strain increases, the sensor output shows a corresponding linear increase in voltage, in line with the piezoelectric governing equation. Additionally, changes in loading frequency affect the curve slope. While these initial results are promising, further analytical development is needed to accurately quantify the PZT output as a function of strain.
Figure 15. (a) Fatigue test setup schematic. (b) PZT sensor output in fatigue loading [108].
Table 6 provides a detailed overview of the applications of strain measurements using piezoelectric sensors for FLM in the literature.
Table 6. Detailed and categorized descriptions of the research in the field of FLM using the piezoelectric sensor as a strain gauge.

3. Signal Processing

The reviewed studies highlight diverse methodologies for processing sensor data. These approaches are tailored to specific applications, such as UT, AE, EMI, and strain measurement, and follow a structured framework that includes signal preprocessing, feature extraction and pattern recognition, data fusion (when multiple techniques are utilized), and subsequent quantification and statistical analysis.
Signal preprocessing is a foundational step reported in most studies. For instance, in UT-based applications, filtering techniques such as bandpass filters are employed to eliminate noise and isolate relevant waveforms [55,65]. Similarly, in EMI-based studies, baseline normalization is frequently used to correct for environmental fluctuations. Time-domain [40,41,43,44,45] and frequency-domain transformations, such as Fourier transforms [52,53,61,103,104], are also applied to enhance signal clarity.
The extraction of meaningful features from the processed signals is a critical step. For example, studies on strain measurement often analyze the amplitude and frequency of the piezoelectric output to detect deformation or fatigue-induced anomalies [108,113]. In EMI-based methods, changes in the resonant frequency or impedance spectrum are key indicators of structural damage [101,102]. In UT and AE applications, features like waveform energy, peak amplitude, and arrival time are commonly used to identify crack initiation and growth.
Advanced statistical and computational techniques are widely used to interpret the extracted features. Regression models and clustering algorithms, machine learning techniques, including neural networks [60], besides time-series and frequency-domain analysis methods, such as STSA [46,47,48], STFT [53], PCA [59], DAE [65], FFT [105], and Chio–Williams transform [86], have been used to monitor the evolution of features, providing insights into fatigue behavior. While the specific methodologies differ depending on the sensor type and application, a common trend is the increasing reliance on automated and computationally efficient techniques for data processing. Studies emphasize the importance of combining multiple features and processing steps to enhance accuracy and reliability. For instance, hybrid approaches integrating UT and AE methods have shown promise in improving the sensitivity of crack detection.

4. Integration Strategies

Integrating UT, AE, EMI, and strain measurement techniques can provide a comprehensive approach to fatigue life monitoring by leveraging the strengths of each method [118,119]. AE is highly effective for real-time active damage detection, especially for early warnings and identifying the onset and propagation of microcracks that may not yet be visible or detectable by other methods such as UT [120]. Complementing this, UT, an active sensing approach, excels in evaluating damage initiation, length, and dimensions, offering detailed insights into the size and morphology of damage [121,122]. EMI and strain measurement techniques fill a gap by providing information on the dynamic strain history of the structure, enabling the estimation of remaining fatigue life without requiring direct damage detection or damage size evaluation [117,123]. By combining these methods, a hybrid system can be developed where UT and AE are deployed for damage-centric inspections, while EMI and strain measurements are employed for global and local structural health assessment and fatigue life prediction. This integrated framework can enable enhanced reliability, early warning capabilities, and the potential for autonomous, data-driven fatigue life management across diverse structural applications.

5. Challenges and Opportunities for Future Research and Development

The literature highlights the promising potential of piezoelectric-based sensors for FLM, offering durability and high sensitivity to dynamic loading, essential for long-term monitoring under real-life conditions. However, challenges such as temperature sensitivity and susceptibility to electromagnetic interference need to be addressed during sensor design and data processing. Given the diverse mechanisms of fatigue-induced failure and material variations, monitoring solutions must be customized for specific applications, where parameters like damage level, crack length, local strain, or vibration play critical roles.
There is a significant gap in comprehensive research to develop cost-effective, reliable, and durable piezoelectric sensors for fatigue life measurement. More work is required to enhance sensor integration, understand long-term performance under varying environmental conditions (e.g., temperature, humidity), and develop low-power, flexible sensors. This will be key to fully leveraging piezoelectric technology for fatigue monitoring. Further research should focus on validating these methods under dynamic, time-varying conditions and explore multi-sensory systems that account for multiple parameters.
Future research and development in piezoelectric sensors for FLM should focus on the following:
  • Sensor materials: Efforts should be directed towards developing high-performance, lead-free piezoelectric materials (e.g., BaTiO3, KNN) through advanced synthesis, characterization, and modelling to improve manufacturability, durability, and piezoelectric properties. Additionally, integrating flexibility and high piezoelectric performance into polymer-based composite materials is key to enhancing adaptability to complex structural loads. Improving sensor resilience to environmental factors such as temperature, humidity, and external loads, along with developing adaptive algorithms to mitigate these effects, is also crucial.
  • Advanced manufacturing and embedded systems: Utilizing additive manufacturing and direct sensor printing to create customizable, scalable piezoelectric sensors. Focus should also be on improving the durability of embedded sensors for long-term use or developing easily replaceable alternatives to cover the structure’s lifetime. For example, civil structures may last over 100 years, and longevity is an important factor for FLM.
  • Multi-sensor integration and systemic investigation: Transitioning from single-sensor to multi-sensor systems to improve accuracy and reliability. Combining piezoelectric sensors with other types of sensors and investigating fatigue damage, crack status, and environmental factors will help create integrated, cost-effective systems. The use of both active and passive monitoring techniques can provide a comprehensive damage assessment, while multifunctional sensors capable of both sensing and energy harvesting can enhance system efficiency and sustainability.
  • Wireless and self-sustained systems: Incorporating wireless communication, self-powering mechanisms, and low-power operation to ensure ease of use and sustainability.
  • Advanced algorithms: Research should focus on developing advanced algorithms for managing big data, utilizing machine learning and AI to improve signal processing, particularly in multi-sensor networks and real-life loading conditions for reliable monitoring.

6. Conclusions

Structural fatigue in engineering materials represents one of the most critical features determining structural integrity, which can lead to structural damage and collapse. Therefore, it is important to evaluate the fatigue-induced reduction in structural integrity, such as loss of stiffness and strength, or to measure fatigue-induced cracks/damage, and estimate the remaining fatigue life of the structure.
Among the available monitoring technologies, piezoelectric materials are widely used for FLM due to their durability, low cost, and high sensitivity for dynamic loadings. Overall, four piezoelectric-based sensing methods are used for this purpose, including UT wave propagation and reflection, in situ monitoring of AE signals related to active cracks and damage, measurement of the electromechanical impedance of sensors dependent on the structural integrity, and dynamic strain profile measurement by measuring the strain variations.
  • UT can detect changes in the mechanical properties of the structure, as well as identify and locate existing cracks and damage at various stages of their development. This method is active and categorized into two modes, pitch–catch and pulse–echo, based on the arrangement of wave transmitters and receivers using piezoelectric sensors; each technique has its capabilities and weaknesses. The UT technique is well-suited for monitoring structures where prior knowledge of crack and damage status exists. It is particularly effective when cracks or damage can be monitored before reaching a critical length. However, its effectiveness is constrained when dealing with large areas that require continuous monitoring and limited information on the size and locations of cracks or damage. This limitation can be addressed through proper calibration and deploying an array of sensor nodes to cover various locations or through periodic UT inspections from different positions, although at an additional cost.
  • AE is a passive method that captures the mechanical wave resulting from active crack/damage under the load, making it an ideal case for early damage detection. AE can also provide the location of active cracks/damage and provide rather qualitative measurements on whether those are in critical status or not. As a result, sometimes, a combination of AE and UT is used to take advantage of early damage detection of AE and accurate damage size measurements of the UT.
  • In EMI methods, the measured electrical impedance of the piezoelectric sensor is related to structural integrity. In simpler terms, changes in the resonance frequency of the sensor reflect changes in the fatigue life of the structure. Impedance spectroscopy is considered an active method as it requires high-frequency electrical currents for measuring electrical impedance.
  • Lastly, the strain sensing method using piezoelectric sensors, in addition to the accuracy and high-frequency response of piezoelectric sensors, provides a passive method capable of measuring dynamic loading-induced strains that are the main cause of structural fatigue failure and can be connected to fatigue life using S-N curves.

Author Contributions

Conceptualization, A.G.; writing—original draft preparation, A.G.; writing—review and editing, E.S. and M.F. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

AEAcoustic Emission
AICAkaike Information Criterion
CFRPCarbon Fiber-Reinforced Polymer
CISSCrack-Induced Second Source
CNNConvolutional Neural Networks
CODCrack Opening Displacement
CVSConcrete Vibration Sensors
CWICoda Wave Interferometry
CWTContinuous Wavelet Transformation
DAEDeep Auto-Encoder
DFTDiscrete Fourier Transform
DIDamage Index
DWTDiscrete Wavelet Transform
EDIEnvelope Damage Index
EMIElectro-Mechanical Impedance
FCDFatigue Crack Diagnosis
FLMFatigue Life Monitoring
GWGuided Waves
MBEJModular Bridge Expansion Joints
MOSMetal–Oxide Semiconductor
MOSFETMetal–Oxide Semiconductor Field Effect Transistors
NDTNon-Destructive Test
NINonlinear Index
PCAPrincipal Component Analysis
PODProbability Of Detection
PTRFEPoly-Trifluoro Ethylene
PVDFPolyvinylidene Fluoride
PWASPiezoelectric Wafer Active Sensors
PZTLead Zirconate Titanate
RMSDRoot Mean Square Deviation
SHMStructural Health Monitoring
SHMUSSHM Ultrasound System
SNRSignal-To-Noise Ratio
STFTShort-Time Fourier Transform
STGStrain Gauge
STSASymbolic Time Series Analysis
TCTransmission Coefficient
TOATime Of Arrival
TOFTime Of Flight
UGW Ultrasonic-Guided Wave
UTUltrasonic Testing
XRDX-Ray Diffraction

References

  1. Santecchia, E.; Hamouda, A.M.S.; Musharavati, F.; Zalnezhad, E.; Cabibbo, M.; El Mehtedi, M.; Spigarelli, S. A Review on Fatigue Life Prediction Methods for Metals. Adv. Mater. Sci. Eng. 2016, 2016, 9573524. [Google Scholar] [CrossRef] [Scilit]
  2. Fajri, A.; Prabowo, A.R.; Muhayat, N.; Smaradhana, D.F.; Bahatmaka, A. Fatigue Analysis of Engineering Structures: State of Development and Achievement. Procedia Struct. Integr. 2021, 33, 19–26. [Google Scholar] [CrossRef] [Scilit]
  3. Schijve, J. Fatigue of Structures and Materials; Springer: Berlin/Heidelberg, Germany, 2009; pp. 1–622. [Google Scholar] [CrossRef] [Scilit]
  4. Chen, A.S.; Harris, B. Fatigue-induced damage mechanisms in carbon fibre-reinforced plastic composites. J. Mater. Sci. 1993, 28, 2013–2027. [Google Scholar] [CrossRef] [Scilit]
  5. Bhalla, S.; Kaur, N. Prognosis of low-strain fatigue induced damage in reinforced concrete structures using embedded piezo-transducers. Int. J. Fatigue 2018, 113, 98–112. [Google Scholar] [CrossRef] [Scilit]
  6. Gao, Z.; Yang, S.; Meng, X.; Wang, Z.; Peng, Z. Study on fatigue crack growth of electron beam selective melting of titanium alloy. Mater. Res. Express 2021, 8, 96521. [Google Scholar] [CrossRef] [Scilit]
  7. Claßen, M.; Gallwoszus, J. Concrete fatigue in composite dowels. Struct. Concr. 2016, 17, 63–73. [Google Scholar] [CrossRef] [Scilit]
  8. Qi, W.; Yao, W.; Shen, H. A Micro-macro Damage Mechanics-based Model for Fatigue Damage and Life Prediction of Fiber-reinforced Composite Laminates. Appl. Compos. Mater. 2022, 29, 1795–1816. [Google Scholar] [CrossRef] [Scilit]
  9. Chen, H.P. Structural Health Monitoring of Large Civil Engineering Structures; WILEY: New York, NY, USA, 2018. [Google Scholar]
  10. Tan, Y.; Liang, Z.; Zhang, X.; Xing, C.; Liu, B.; Wang, W. Application of smartrock sensors in monitoring the motion of asphalt pavements aggregates and ballast particles: A comprehensive review. Innov. Infrastruct. Solut. 2024, 9, 1–21. [Google Scholar] [CrossRef] [Scilit]
  11. Zhang, X.; Wang, Y.; Shi, X.; Jian, J.; Wang, X.; Li, M.; Ji, Y.; Qian, F.; Fan, J.; Wang, H.; et al. Heteroepitaxy of flexible piezoelectric Pb(Zr0.53Ti0.47)O3 sensor on inorganic mica substrate for lamb wave-based structural health monitoring. Ceram. Int. 2021, 47, 13156–13163. [Google Scholar] [CrossRef] [Scilit]
  12. Guo, S.; Chen, S.; Zhang, L.; Liew, W.H.; Yao, K. Direct-write piezoelectric ultrasonic transducers for pipe structural health monitoring. Ndt E Int. 2019, 107, 102131. [Google Scholar] [CrossRef] [Scilit]
  13. Li, Y.; Feng, W.; Meng, L.; Tse, K.M.; Li, Z.; Huang, L.; Su, Z.; Guo, S. Investigation on in-situ sprayed, annealed and corona poled PVDF-TrFE coatings for guided wave-based structural health monitoring: From crystallization to piezoelectricity. Mater. Des. 2020, 199, 109415. [Google Scholar] [CrossRef] [Scilit]
  14. Song, S.; Hou, Y.; Guo, M.; Wang, L.; Tong, X.; Wu, J. An investigation on the aggregate-shape embedded piezoelectric sensor for civil infrastructure health monitoring. Constr. Build. Mater. 2017, 131, 57–65. [Google Scholar] [CrossRef] [Scilit]
  15. Miao, H.; Li, F. Shear horizontal wave transducers for structural health monitoring and nondestructive testing: A review. Ultrasonics 2021, 114, 106355. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Jiao, P.; Egbe, K.J.I.; Xie, Y.; Nazar, A.M.; Alavi, A.H. Piezoelectric Sensing Techniques in Structural Health Monitoring: A State-of-the-Art Review. Sensors 2020, 20, 3730. [Google Scholar] [CrossRef] [Scilit]
  17. Song, G.; Gu, H.; Li, H. Application of the Piezoelectric Materials for Health Monitoring in Civil Engineering: An Overview. In Engineering, Construction, and Operations in Challenging Environments: Earth and Space 2004; American Society of Civil Engineers: Reston, VA, USA, 2004; pp. 680–687. [Google Scholar] [CrossRef] [Scilit]
  18. Singh Aulakh, D.; Bhalla, S. Piezo sensor-based operational strain modal analysis of structures: Transition from lab to field application. Measurement 2025, 239, 115398. [Google Scholar] [CrossRef] [Scilit]
  19. Na, W.S.; Baek, J. A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures. Sensors 2018, 18, 1307. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Huynh, T.C.; Dang, N.L.; Kim, J.T. Advances and challenges in impedance-based structural health monitoring. Struct. Monit. Maint. 2017, 4, 301–329. [Google Scholar] [CrossRef]
  21. Tuloup, C.; Harizi, W.; Aboura, Z.; Meyer, Y.; Khellil, K.; Lachat, R. On the use of in-situ piezoelectric sensors for the manufacturing and structural health monitoring of polymer-matrix composites: A literature review. Compos. Struct. 2019, 215, 127–149. [Google Scholar] [CrossRef] [Scilit]
  22. Ju, M.; Dou, Z.; Li, J.W.; Qiu, X.; Shen, B.; Zhang, D.; Yao, F.Z.; Gong, W.; Wang, K. Piezoelectric Materials and Sensors for Structural Health Monitoring: Fundamental Aspects, Current Status, and Future Perspectives. Sensors 2023, 23, 543. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Parida, L.; Moharana, S. A comprehensive review on piezo impedance based multi sensing technique. Results Eng. 2023, 18, 101093. [Google Scholar] [CrossRef] [Scilit]
  24. Ali, A.; Ali, S.; Shaukat, H.; Khalid, E.; Behram, L.; Rani, H.; Altabey, W.A.; Kouritem, S.A.; Noori, M. Advancements in piezoelectric wind energy harvesting: A review. Results Eng. 2024, 21, 101777. [Google Scholar] [CrossRef] [Scilit]
  25. Tuloup, C.; Harizi, W.; Aboura, Z.; Meyer, Y. Integration of piezoelectric transducers (PZT and PVDF) within polymer-matrix composites for structural health monitoring applications: New success and challenges. Int. J. Smart Nano Mater. 2020, 11, 343–369. [Google Scholar] [CrossRef] [Scilit]
  26. Qing, X.; Li, W.; Wang, Y.; Sun, H. Piezoelectric Transducer-Based Structural Health Monitoring for Aircraft Applications. Sensors 2019, 19, 545. [Google Scholar] [CrossRef] [Scilit]
  27. Chen, Y.; Xue, X. Advances in the Structural Health Monitoring of Bridges Using Piezoelectric Transducers. Sensors 2018, 18, 4312. [Google Scholar] [CrossRef] [Scilit]
  28. Le, T.C.; Luu, T.H.T.; Nguyen, H.P.; Nguyen, T.H.; Ho, D.D.; Huynh, T.C. Piezoelectric Impedance-Based Structural Health Monitoring of Wind Turbine Structures: Current Status and Future Perspectives. Energies 2022, 15, 5459. [Google Scholar] [CrossRef] [Scilit]
  29. Kaewniam, P.; Cao, M.; Alkayem, N.F.; Li, D.; Manoach, E. Recent advances in damage detection of wind turbine blades: A state-of-the-art review. Renew. Sustain. Energy Rev. 2022, 167, 112723. [Google Scholar] [CrossRef] [Scilit]
  30. Chen, C.; Shen, Y.J.; Chou, P.Y.; Wang, P.H. A Lamb-wave based SHM for multi-damage localizations in large composite plates by using piezoelectric transducer array. SMaS 2024, 33, 045028. [Google Scholar] [CrossRef] [Scilit]
  31. Aabid, A.; Parveez, B.; Raheman, M.A.; Ibrahim, Y.E.; Anjum, A.; Hrairi, M.; Parveen, N.; Mohammed Zayan, J. A Review of Piezoelectric Material-Based Structural Control and Health Monitoring Techniques for Engineering Structures: Challenges and Opportunities. Actuators 2021, 10, 101. [Google Scholar] [CrossRef] [Scilit]
  32. View of A Comprehensive Review of Nanocomposite PVDF as a Piezoelectric Material: Evaluating Manufacturing Methods, Energy Efficiency and Performance. Available online: https://eaapublishing.org/journals/index.php/nanofab/article/view/1775/1900 (accessed on 24 February 2024).
  33. Abbas, M.; Shafiee, M. Structural Health Monitoring (SHM) and Determination of Surface Defects in Large Metallic Structures using Ultrasonic Guided Waves. Sensors 2018, 18, 3958. [Google Scholar] [CrossRef] [Scilit]
  34. Zhu, X.; Rizzo, P.; Marzani, A.; Bruck, J. Ultrasonic guided waves for nondestructive evaluation/structural health monitoring of trusses. Meas. Sci. Technol. 2010, 21, 045701. [Google Scholar] [CrossRef] [Scilit]
  35. Jodhani, J.; Handa, A.; Gautam, A.; Ashwni; Rana, R. Ultrasonic non-destructive evaluation of composites: A review. Mater. Today Proc. 2023, 78, 627–632. [Google Scholar] [CrossRef] [Scilit]
  36. Masmoudi, M.; Yaacoubi, S.; Koabaz, M.; Akrout, M.; Skaiky, A. On the use of ultrasonic guided waves for the health monitoring of rails. Proc. Inst. Mech. Eng. Part F J. Rail Rapid Transit 2022, 236, 469–489. [Google Scholar] [CrossRef] [Scilit]
  37. Li, N.; Sepúlveda, N.; Li, N. Implications of a consistency-oriented sync API in an ERP to cloud integration library—A case study. In Proceedings of the 2011 IEEE International Conference on Robotics and Biomimetics, Timisoara, Romania, 27–28 October 2016; Available online: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7781053%0Ahttps://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5485276%0Ahttps://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9511469%0Ahttps://ieeexplore-ieee-org.uproxy.library.dc-uoit.ca/ (accessed on 11 July 2024).
  38. Li, X.; Yang, J.; Zhang, G. A Crack Size Quantification Method Using High-Resolution Lamb Waves. Sensors 2021, 21, 6941. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Sampath, S.; Sohn, H. Non-contact microcrack detection via nonlinear Lamb wave mixing and laser line arrays. Int. J. Mech. Sci. 2023, 237, 107769. [Google Scholar] [CrossRef] [Scilit]
  40. Ihn, J.B.; Chang, F.K. Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: II. Validation using riveted joints and repair patches. Smart Mater. Struct. 2004, 13, 621–630. [Google Scholar] [CrossRef] [Scilit]
  41. Ihn, J.B.; Chang, F.K. Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: I. Diagnostics. Smart Mater. Struct. 2004, 13, 609–620. [Google Scholar] [CrossRef] [Scilit]
  42. Tiwari, K.A.; Raisutis, R.; Mazeika, L. Analysis of Wave Patterns Under the Region of Macro-Fiber Composite Transducer to Improve the Analytical Modelling for Directivity Calculation in Isotropic Medium. Sensors 2020, 20, 2280. [Google Scholar] [CrossRef] [Scilit]
  43. Michaels, J.E.; Michaels, T.E.; Mi, B.; Cobb, A.C.; Stobbe, D.M. Self-calibrating ultrasonic methods for in-situ monitoring of fatigue crack progression. AIP Conf. Proc. 2005, 760, 1765–1772. [Google Scholar]
  44. Mi, B.; Michaels, T.E.; Michaels, J.E. In-situ ultrasonic monitoring of crack growth under static and dynamic loading conditions. In Proceedings of the Nondestructive Evaluation and Health Monitoring of Aerospace Materials, Composites, and Civil Infrastructure IV, San Diego, CA, USA, 8–10 March 2005; Volume 5767, p. 1. [Google Scholar]
  45. Mi, B.; Michaels, J.E.; Michaels, T.E. An ultrasonic method for dynamic monitoring of fatigue crack initiation and growth. J. Acoust. Soc. Am. 2006, 119, 74–85. [Google Scholar] [CrossRef] [Scilit]
  46. Gupta, S.; Ray, A.; Keller, E. Online fatigue damage monitoring by ultrasonic measurements: A symbolic dynamics approach. Int. J. Fatigue 2007, 29, 1100–1114. [Google Scholar] [CrossRef] [Scilit]
  47. Gupta, S.; Ray, A. Real-time fatigue life estimation in mechanical structures. Meas. Sci. Technol. 2007, 18, 1947–1957. [Google Scholar] [CrossRef] [Scilit]
  48. Gupta, S.; Singh, D.S.; Ray, A. Statistical pattern analysis of ultrasonic signals for fatigue damage detection in mechanical structures. Ndt E Int. 2008, 41, 491–500. [Google Scholar] [CrossRef] [Scilit]
  49. Rizzo, P.; Cammarata, M.; Dutta, D.; Sohn, H. An unsupervised learning algorithm for fatigue crack detection in waveguides. Smart Mater. Struct. 2009, 18, 025016. [Google Scholar] [CrossRef] [Scilit]
  50. Zhou, C.; Hong, M.; Su, Z.; Wang, Q.; Cheng, L. Evaluation of fatigue cracks using nonlinearities of acousto-ultrasonic waves acquired by an active sensor network. Smart Mater. Struct. 2013, 22, 015018. [Google Scholar] [CrossRef] [Scilit]
  51. Cho, H.; Lissenden, C.J. Structural health monitoring of fatigue crack growth in plate structures with ultrasonic guided waves. Struct. Health Monit. 2012, 11, 393–404. [Google Scholar] [CrossRef] [Scilit]
  52. Su, Z.; Zhou, C.; Hong, M.; Cheng, L.; Wang, Q.; Qing, X. Acousto-ultrasonics-based fatigue damage characterization: Linear versus nonlinear signal features. Mech. Syst. Signal Process. 2014, 45, 225–239. [Google Scholar] [CrossRef] [Scilit]
  53. Hong, M.; Su, Z.; Wang, Q.; Cheng, L.; Qing, X. Modeling nonlinearities of ultrasonic waves for fatigue damage characterization: Theory, simulation, and experimental validation. Ultrasonics 2014, 54, 770–778. [Google Scholar] [CrossRef] [Scilit]
  54. Chan, H.; Masserey, B.; Fromme, P. High frequency guided ultrasonic waves for hidden fatigue crack growth monitoring in multi-layer model aerospace structures. Smart Mater. Struct. 2015, 24, 025037. [Google Scholar] [CrossRef] [Scilit]
  55. Liu, P.; Lim, H.J.; Yang, S.; Sohn, H.; Lee, C.H.; Yi, Y.; Kim, D.; Jung, J.; Bae, I.H. Development of a “stick-and-detect” wireless sensor node for fatigue crack detection. Struct. Health Monit. 2017, 16, 153–163. [Google Scholar] [CrossRef] [Scilit]
  56. Haile, M.A.; Riddick, J.C.; Assefa, A.H. Robust Particle Filters for Fatigue Crack Growth Estimation in Rotorcraft Structures. IEEE Trans. Reliab. 2016, 65, 1438–1448. [Google Scholar] [CrossRef] [Scilit]
  57. Wang, D.; He, J.; Guan, X.; Yang, J.; Zhang, W. A model assessment method for predicting structural fatigue life using Lamb waves. Ultrasonics 2018, 84, 319–328. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  58. Jiang, T.; Zhang, Y.; Wang, L.; Zhang, L.; Song, G. Monitoring fatigue damage of modular bridge expansion joints using piezoceramic transducers. Sensors 2018, 18, 3973. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  59. Jin, H.; Yan, J.; Li, W.; Qing, X. Monitoring of fatigue crack propagation by damage index of ultrasonic Guided Waves calculated by various acoustic features. Appl. Sci. 2019, 9, 254. [Google Scholar] [CrossRef] [Scilit]
  60. Xu, L.; Yuan, S.; Chen, J.; Ren, Y. Guided wave-convolutional neural network based fatigue crack diagnosis of aircraft structures. Sensors 2019, 19, 3567. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  61. Xu, L.; Wang, K.; Yang, X.; Su, Y.; Yang, J.; Liao, Y.; Zhou, P.; Su, Z. Model-driven fatigue crack characterization and growth prediction: A two-step, 3-D fatigue damage modeling framework for structural health monitoring. Int. J. Mech. Sci. 2021, 195, 106226. [Google Scholar] [CrossRef] [Scilit]
  62. Xiao, W.; Yu, L.; Joseph, R.; Giurgiutiu, V. Fatigue-crack detection and monitoring through the scattered-wave two-dimensional cross-correlation imaging method using piezoelectric transducers. Sensors 2020, 20, 3035. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  63. Zhou, D.; Huo, L.; Chen, D.; Song, G. A feasibility study on monitoring of weld fatigue crack growth based on coda wave interferometry (CWI). Smart Mater. Struct. 2021, 30, 095013. [Google Scholar] [CrossRef] [Scilit]
  64. Zeng, X.; Liu, X.; Sun, H.; Qing, X. Prognosis of fatigue cracks in an aircraft wing using an adaptive tunable network and guided wave based structural health monitoring. Smart Mater. Struct. 2021, 30, 105025. [Google Scholar] [CrossRef] [Scilit]
  65. Lee, H.; Lim, H.J.; Skinner, T.; Chattopadhyay, A.; Hall, A. Automated fatigue damage detection and classification technique for composite structures using Lamb waves and deep autoencoder. Mech. Syst. Signal Process. 2021, 163, 108148. [Google Scholar] [CrossRef] [Scilit]
  66. Nobile, R.; Panella, F.W.; Antonazzo, R.; Pirinu, A.; Saponaro, A. Fatigue damage evolution using NDT techniques for Health Monitoring of CFRP laminates. IOP Conf. Ser. Mater. Sci. Eng. 2022, 1214, 012011. [Google Scholar] [CrossRef] [Scilit]
  67. Lee, Y.F.; Lu, Y. Identification of fatigue crack under vibration by nonlinear guided waves. Mech. Syst. Signal Process. 2022, 163, 108138. [Google Scholar] [CrossRef] [Scilit]
  68. Chen, C.-D.; Hsieh, C.-H.; Liu, C.-Y.; Huang, Y.-H.; Wang, P.-H.; Chien, R.-D. Lamb Wave–Based Structural Health Monitoring for Aluminum Bolted Joints with Multiple-Site Fatigue Damage. J. Aerosp. Eng. 2022, 35, 04022101. [Google Scholar] [CrossRef] [Scilit]
  69. Wong, V.K.; Liu, M.; Goh, W.P.; Chen, S.; Zheng Wong, Z.; Cui, F.; Yao, K. Structural health monitoring of fastener hole using ring-design direct-write piezoelectric ultrasonic transducer. Struct. Health Monit. 2022, 21, 2657–2669. [Google Scholar] [CrossRef] [Scilit]
  70. Li, X.; Wong, V.K.; Yousry, Y.M.; Lim, D.B.K.; Christopher Subhodayam, P.T.; Yao, K.; Feng, L.; Qian, X.; Fan, Z. Surface Crack Monitoring by Rayleigh Waves with a Piezoelectric-Polymer-Film Ultrasonic Transducer Array. Sensors 2023, 23, 2665. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  71. Ji, B.; Qu, W. The research of acoustic emission techniques for non destructive testing and health monitoring on civil engineering structures. In Proceedings of the 2008 International Conference on Condition Monitoring and Diagnosis, Beijing, China, 21–24 April 2008; pp. 782–785. [Google Scholar] [CrossRef] [Scilit]
  72. Gholizadeh, S.; Leman, Z.; Baharudin, B.T.H.T. A review of the application of acoustic emission technique in engineering. Struct. Eng. Mech. 2015, 54, 1075–1095. [Google Scholar] [CrossRef] [Scilit]
  73. Abouhussien, A.A.; Hassan, A.A.A. Evaluation of damage progression in concrete structures due to reinforcing steel corrosion using acoustic emission monitoring. J. Civ. Struct. Health Monit. 2015, 5, 751–765. [Google Scholar] [CrossRef] [Scilit]
  74. Pollock, A.A. Acoustic Emission Inspection, Metals Handbook; ASM International: Almere, The Netherlands, 1976; Volume 48, ISBN 9783540698951. [Google Scholar]
  75. Ni, Q.Q.; Iwamoto, M. Wavelet transform of acoustic emission signals in failure of model composites. Eng. Fract. Mech. 2002, 69, 717–728. [Google Scholar] [CrossRef] [Scilit]
  76. Pinal Moctezuma, F.; Delgado Prieto, M.; Romeral Martinez, L. Performance analysis of acoustic emission hit detection methods using time features. IEEE Access 2019, 7, 71119–71130. [Google Scholar] [CrossRef] [Scilit]
  77. Ince, N.F.; Kao, C.S.; Kaveh, M.; Tewfik, A.; Labuz, J.F. A machine learning approach for locating acoustic emission. EURASIP J. Adv. Signal Process. 2010, 2010, 895486. [Google Scholar] [CrossRef] [Scilit]
  78. Scruby, C.B. An introduction to acoustic emission. J. Phys. E Sci. Instrum. 1987, 20, 946. [Google Scholar] [CrossRef] [Scilit]
  79. Saeedifar, M.; Fotouhi, M.; Ahmadi Najafabadi, M.; Hosseini Toudeshky, H.; Minak, G. Prediction of quasi-static delamination onset and growth in laminated composites by acoustic emission. Compos. Part B Eng. 2016, 85, 113–122. [Google Scholar] [CrossRef] [Scilit]
  80. Gholizadeh, A.; Mansouri, H.; Nikbakht, A.; Saghafi, H.; Fotouhi, M. Applying Acoustic Emission Technique for Detecting Various Damages Occurred in PCL Nanomodified Composite Laminates. Polymers 2021, 13, 3680. [Google Scholar] [CrossRef] [Scilit]
  81. Jacques, R.; Clarke, T.; Morikawa, S.; Strohaecker, T. Monitoring the structural integrity of a flexible riser during dynamic loading with a combination of non-destructive testing methods. Ndt E Int. 2010, 43, 501–506. [Google Scholar] [CrossRef] [Scilit]
  82. Clarke, T.; Jacques, R.; Bisognin, A.; Camerini, C.; Damasceno, S.; Strohaecker, T. Monitoring the structural integrity of a flexible riser during a full-scale fatigue test. Eng. Struct. 2011, 33, 1181–1186. [Google Scholar] [CrossRef] [Scilit]
  83. Gagar, D.; Foote, P.; Irving, P.E. Effects of loading and sample geometry on acoustic emission generation during fatigue crack growth: Implications for structural health monitoring. Int. J. Fatigue 2015, 81, 117–127. [Google Scholar] [CrossRef] [Scilit]
  84. Pearson, M.R.; Eaton, M.; Featherston, C.; Pullin, R.; Holford, K. Improved acoustic emission source location during fatigue and impact events in metallic and composite structures. Struct. Health Monit. 2017, 16, 382–399. [Google Scholar] [CrossRef] [Scilit]
  85. Shamsudin, M.F.; Mares, C.; Johnston, C.; Lage, Y.; Edwards, G.; Gan, T.H. Application of Bayesian estimation to structural health monitoring of fatigue cracks in welded steel pipe. Mech. Syst. Signal Process. 2019, 121, 112–123. [Google Scholar] [CrossRef] [Scilit]
  86. Garrett, J.C.; Mei, H.; Giurgiutiu, V. An Artificial Intelligence Approach to Fatigue Crack Length Estimation from Acoustic Emission Waves in Thin Metallic Plates. Appl. Sci. 2022, 12, 1372. [Google Scholar] [CrossRef] [Scilit]
  87. Banjara, N.K.; Sasmal, S.; Kapuria, S. Fatigue and leakage-type damage detection in metallic plates and pipelines using piezoelectric patch acoustic sensors. Int. J. Press. Vessel. Pip. 2024, 209, 105162. [Google Scholar] [CrossRef] [Scilit]
  88. Mazal, P.; Vlasic, F.; Koula, V. Use of Acoustic Emission Method for Identification of Fatigue Micro-cracks Creation. Procedia Eng. 2015, 133, 379–388. [Google Scholar] [CrossRef] [Scilit]
  89. Felice, M.V.; Velichko, A.; Wilcox, P.D. Accurate depth measurement of small surface-breaking cracks using an ultrasonic array post-processing technique. Ndt E Int. 2014, 68, 105–112. [Google Scholar] [CrossRef] [Scilit]
  90. Grondel, Â.; Delebarre, C.; Assaad, J.; Dupuis, J.-P.; Reithler, L. Fatigue Crack Monitoring of Riveted Aluminium Strap Joints by Lamb Wave Analysis and Acoustic Emission Measurement Techniques. NDT & E Int. 2002, 35, 137–146. [Google Scholar] [CrossRef] [Scilit]
  91. Gresil, M.; Yu, L.; Giurgiutiu, V. Fatigue crack detection in thick steel structures with piezoelectric wafer active sensors. In Proceedings of the Nondestructive Characterization for Composite Materials, Aerospace Engineering, Civil Infrastructure, and Homeland Security, San Diego, CA, USA, 19 April 2011; Volume 7983, p. 79832Y. [Google Scholar]
  92. Mei, H.; Haider, M.F.; Joseph, R.; Migot, A.; Giurgiutiu, V. Recent advances in piezoelectric wafer active sensors for structural health monitoring applications. Sensors 2019, 19, 383. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  93. Etxaniz, J.; Aranguren, G.; Gil-García, J.M.; Sánchez, J.; Vivas, G.; González, J. Ultrasound-based structural health monitoring methodology employing active and passive techniques. Eng. Fail. Anal. 2023, 146, 107077. [Google Scholar] [CrossRef] [Scilit]
  94. Liang, C.; Sun, F.P.; Rogers, C.A. Coupled electro-mechanical analysis of adaptive material systems—Determination of the actuator power consumption and system energy transfer. J. Intell. Mater. Syst. Struct. 1997, 8, 335–343. [Google Scholar] [CrossRef] [Scilit]
  95. Buethe, I.; Moix-Bonet, M.; Wierach, P.; Fritzen, C.-P. Check of Piezoelectric Transducers Using the Electro-Mechanical Impedance. 2014. Available online: https://inria.hal.science/hal-01020432 (accessed on 22 April 2023).
  96. Giurgiutiu, V.; Rogers, C.A. Recent advancements in the electromechanical (E/M) impedance method for structural health monitoring and NDE. In Smart Structures and Materials 1998: Smart Structures and Integrated Systems; SPIE Digital Library: Bellingham, WA, USA, 1998; Volume 3329, pp. 536–547. [Google Scholar] [CrossRef] [Scilit]
  97. Baptista, F.G.; Budoya, D.E.; de Almeida, V.A.D.; Ulson, J.A.C. An Experimental Study on the Effect of Temperature on Piezoelectric Sensors for Impedance-Based Structural Health Monitoring. Sensors 2014, 14, 1208–1227. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  98. Soh, C.K.; Lim, Y.Y. Detection and Characterization of Fatigue Induced Damage Using Electromechanical Impedance Technique. Adv. Mater. Res. 2009, 79–82, 2031–2034. [Google Scholar] [CrossRef] [Scilit]
  99. Li, J.; Luo, Z.; Lin, L.; Li, X.; Lei, M. Quantitative health monitoring of fatigue crack initiation and propagation in aluminium specimen based on electromechanical impedance technique. Insight Non-Destr. Test. Cond. Monit. 2012, 54, 267–271. [Google Scholar] [CrossRef] [Scilit]
  100. Giurgiutiu, V.; Xu, B.; Chao, Y.; Liu, S.; Gaddam, R. Smart sensors for monitoring crack growth under fatigue loading conditions. Smart Struct. Syst. 2006, 2, 101–113. [Google Scholar] [CrossRef] [Scilit]
  101. Bhalla, S.; Vittal, P.A.; Veljkovic, M. Piezo-impedance transducers for residual fatigue life assessment of bolted steel joints. Struct. Health Monit. 2012, 11, 733–750. [Google Scholar] [CrossRef] [Scilit]
  102. Haq, M.U.; Bhalla, S.; Naqvi, T. Fatigue Damage Assessment of RC Column using PZT Sensors. Procedia Eng. 2017, 173, 1223–1230. [Google Scholar] [CrossRef] [Scilit]
  103. Haq, M.; Bhalla, S.; Naqvi, T. Fatigue damage and residual fatigue life assessment in reinforced concrete frames using PZT-impedance transducers. Cem. Concr. Compos. 2020, 114, 103771. [Google Scholar] [CrossRef] [Scilit]
  104. Haq, M.; Bhalla, S.; Naqvi, T. Fatigue damage monitoring of reinforced concrete frames using wavelet transform energy of PZT-based admittance signals. Meas. J. Int. Meas. Confed. 2020, 164, 108033. [Google Scholar] [CrossRef] [Scilit]
  105. Haq, M.; Bhalla, S.; Naqvi, T. Piezo-impedance based fatigue damage monitoring of restrengthened concrete frames. Compos. Struct. 2022, 280, 114868. [Google Scholar] [CrossRef] [Scilit]
  106. Ali, L.; Khan, S.; Bashmal, S.; Iqbal, N.; Dai, W.; Bai, Y. Fatigue crack monitoring of t-type joints in steel offshore oil and gas jacket platform. Sensors 2021, 21, 3294. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  107. Sirohi, J.; Chopra, I. Fundamental Understanding of Piezoelectric Strain Sensors. In Smart Structures and Materials 1999: Smart Structures and Integrated Systems; SPIE: Bellingham, WA, USA, 1999. [Google Scholar] [CrossRef] [Scilit]
  108. Ghaderiaram, A.; Mohammadi, R.; Schlangen, E.; Fotouhi, M. Development of an Innovative Extension for Fatigue Life Monitoring Using a Piezoelectric Sensor. Procedia Struct. Integr. 2023, 52, 570–582. [Google Scholar] [CrossRef] [Scilit]
  109. Fotouhi, S.; Akrami, R.; Ferreira-Green, K.; Naser, G.A.M.; Fotouhi, M.; Fragassa, C. Piezoelectric PVDF sensor as a reliable device for strain/load monitoring of engineering structures. IOP Conf. Ser. Mater. Sci. Eng. 2019, 659, 012085. [Google Scholar] [CrossRef] [Scilit]
  110. Aulakh, D.S.; Bhalla, S. Alternate strain based-modal analysis using piezosensors. In Nondestructive Characterization and Monitoring of Advanced Materials, Aerospace, Civil Infrastructure, and Transportation XIV; SPIE: Bellingham, WA, USA, 2020; Volume 11380, pp. 165–170. [Google Scholar] [CrossRef] [Scilit]
  111. Aulakh, D.S.; Bhalla, S. 3D torsional experimental strain modal analysis for structural health monitoring using piezoelectric sensors. Measurement 2021, 180, 109476. [Google Scholar] [CrossRef] [Scilit]
  112. Zhang, Y. In situ fatigue crack detection using piezoelectric paint sensor. J. Intell. Mater. Syst. Struct. 2006, 17, 843–852. [Google Scholar] [CrossRef] [Scilit]
  113. Lajnef, N.; Rhimi, M.; Chatti, K.; Mhamdi, L.; Faridazar, F. Toward an integrated smart sensing system and data interpretation techniques for pavement fatigue monitoring. Comput. Civ. Infrastruct. Eng. 2011, 26, 513–523. [Google Scholar] [CrossRef] [Scilit]
  114. Alavi, A.H.; Hasni, H.; Jiao, P.; Borchani, W.; Lajnef, N. Fatigue cracking detection in steel bridge girders through a self-powered sensing concept. J. Constr. Steel Res. 2017, 128, 19–38. [Google Scholar] [CrossRef] [Scilit]
  115. Kim, D.H.; Hwang, H.Y.; Kim, S.S. Fabrication of PVDF film sensors for fatigue damage monitoring of single-lap adhesive joints. Compos. Struct. 2019, 207, 223–231. [Google Scholar] [CrossRef] [Scilit]
  116. Hughes, J.M.; Wallbrink, C.; Kotousov, A. Cycle-by-cycle crack closure measurements and fatigue crack growth in CT specimen made of 7075-T7351 aluminium. Procedia Struct. Integr. 2023, 45, 44–51. [Google Scholar] [CrossRef] [Scilit]
  117. Wallbrink, C.; Hughes, J.M.; Kotousov, A. Application of an advanced piezoelectric strain sensor for crack closure measurement. Int. J. Fatigue 2023, 167, 107286. [Google Scholar] [CrossRef] [Scilit]
  118. Salifu, S.; Olubambi, P.A. View of A Review of Fatigue Failure and Life Estimation Models: From Classical Methods to Innovative Approaches. Sci. Eng. Technol. 2024, 4, 1724. [Google Scholar] [CrossRef] [Scilit]
  119. Nagaraj, P. Study of Fatigue Damage Detection by Current Information of Measurement System. Ph.D. Thesis, Riga Technical University, Rīga, LV, USA, 2023. [Google Scholar]
  120. Liu, M.; Lu, J.; Ming, P.; Song, J. AE-based damage identification of concrete structures under monotonic and fatigue loading. Constr. Build. Mater. 2023, 377, 131112. [Google Scholar] [CrossRef] [Scilit]
  121. Duchene, P.; Chaki, S.; Ayadi, A.; Krawczak, P. A review of non-destructive techniques used for mechanical damage assessment in polymer composites. J. Mater. Sci. 2018, 53, 7915–7938. [Google Scholar] [CrossRef] [Scilit]
  122. Banerjee, S.; Ahmed, R. Precursor/incubation of multi-scale damage state quantification in composite materials: Using hybrid microcontinuum field theory and high-frequency ultrasonics. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 2013, 60, 1141–1151. [Google Scholar] [CrossRef] [Scilit]
  123. Lim, Y.Y.; Soh, C.K. Estimation of fatigue life using electromechanical impedance technique. In Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2010; SPIE: Bellingham, WA, USA, 2010; Volume 7647, pp. 631–642. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.