Abstract
As a vital chemical feedstock, hydrazine has been widely utilized in multiple fields, thereby driving industrial progress and improving human living standards. Nevertheless, due to its toxicity and persistence, the ubiquitous utilization of hydrazine can trigger detrimental effects on biological systems and environmental matrices. Accordingly, the construction of rapid and sensitive analytical platforms for environmental monitoring of hydrazine is of great importance. This led to the discovery of diverse organic fluorescent sensors for the detection of hydrazine in environmental and biological systems. Herein, this review summarizes the recent design strategies for developing hydrazine organic fluorescent probes, including the general molecular structures, sensing mechanism, and applications.
1. Introduction
Hydrazine (N2H4) is a colorless oily liquid with wide applications in pharmaceuticals, agrochemicals, fine chemicals, and polymer foams by virtue of its strong reducing power, high alkalinity, and nucleophilicity [1,2]. In addition, N2H4 serves as a high-energy propellant for aerospace systems, including rockets, spacecraft, and satellites, benefiting from its high reactivity and combustibility [3,4]. Nevertheless, N2H4 features high volatility and favorable water solubility, which enables it to readily penetrate biological membranes [5,6]. Excessive N2H4 residue in soil, water, and air can cause environmental contamination and threaten ecosystem stability. Moreover, environmental N2H4 residue can accumulate in humans and animals via the food chain, thereby creating severe public-health hazards [7]. Excessive or chronic exposure to N2H4 can lead to multi-organ dysfunction, carcinogenic risks, and irreversible damage to the central nervous system [8,9,10,11]. According to the U.S. Environmental Protection Agency (EPA), N2H4 has been classified as hazard Group B2, and the threshold for N2H4 residues in drinking water should be less than 10 ppb (0.31 μM) [12,13]. Hence, it is imperative to establish facile, sensitive, and selective analytical sensing platforms for monitoring N2H4 within the environmental and biological matrices.
Traditional analytical approaches for N2H4 detection mainly include chromatography [14,15], spectrophotometry [16], electrochemistry [17,18,19], titration, and surface-enhanced Raman spectroscopy [20], which, however, are poorly adapted to on-site monitoring due to the requirement of bulky instruments, laborious sample pretreatment, and well-trained operators. In recent years, small molecule fluorescent probes have gained much attention for N2H4 sensing, owing to their structural versatility, facile tunability, high sensitivity, favorable selectivity, facile visual readout capability, and operational simplicity, as well as good compatibility with biological and environmental scenarios [21,22,23,24,25,26,27,28,29,30].
Current design strategies for N2H4 fluorescent probes focus on grafting reactive recognition sites onto well-established fluorophore skeletons. Typical reactive groups include ester, cyano substituent, cyclic 1,3-diketone, aldehyde, imide, chalcone, and others, which undergo deprotection, hydrazone-formation, or cyclization transformations upon reaction with N2H4. Taking advantage of photo-induced electron transfer (PET), intramolecular charge transfer (ICT), excited-state intramolecular proton transfer (ESIPT), and Förster resonance energy transfer (FRET) mechanisms, these probes realized N2H4 detection and bioimaging in cells, tissues, food specimens, and environmental matrices. This review summarizes recent advances in fluorescent probes for N2H4 detection reported since 2022, classifying probes by their reactive sites. Representative examples are discussed regarding sensing mechanisms, photophysical properties, real-world environmental applications, and biological imaging capabilities. Emerging molecular design strategies are also highlighted. This review is expected to offer useful guidelines for the rational fabrication of high-performance N2H4-responsive fluorescent chemodosimeters.
2. Organic Fluorescent Probes for N2H4
Among diverse fluorescence sensing modes, most N2H4 probes are reaction-type chemodosimeters. Due to the strong nucleophilicity of N2H4, it can attack electrophilic recognition groups and induce chemical transformations that modulate fluorescence signals (Scheme 1). To date, numerous N2H4-sensing fluorescent sensors have been constructed on the basis of various fluorophore skeletons. According to the recognition groups, N2H4 probes can be classified into the following categories.
Scheme 1.
Reaction process based on ester probes: (a) Acetyl and (hetero)aroyl ester; (b) Cinnamoyl ester; (c) 4-Bromobutyryl ester.
2.1. Ester-Based Probes
Ester-based moieties represent one of the most popular recognition motifs for constructing N2H4-responsive fluorescent probes. The general design principle relies on acyl modification of hydroxyl groups on fluorophores to suppress intrinsic ICT or ESIPT pathways, thereby quenching fluorescence emission. As a potent nucleophile, hydrazine can selectively cleave the acyl-ester linkage and regenerate the electron-rich hydroxyl group (Scheme 1). In most cases, restoration of the fluorophore’s push-pull electronic configuration gives rise to prominent fluorescence turn-on or ratiometric spectral responses. In recent years, great advances have been made by exploiting various fluorophore skeletons and fine-tuning ester structures, affording probes with improved sensitivity, near-infrared (NIR) emission, enhanced aqueous solubility, and versatile multifunctional performances.
2.1.1. Acetyl Ester as the Recognition Moiety
Acetyl ester stands as the most straightforward phenolic carboxylate-ester recognition unit for hydrazine probes. Owing to its small steric hindrance and facile synthetic accessibility, the acetyl group can be readily introduced onto various fluorophores.
As natural fluorophores, flavonols feature aggregation-induced emission (AIE) and ESIPT properties, along with favorable photostability, decent quantum yields, and good biocompatibility. Acetylation at the 3-hydroxyl site inhibits ESIPT, and N2H4-triggered cleavage of this unit recovers ESIPT, affording a flavonol-based ratiometric or turn-on sensing platform for N2H4. In 2023, dual-responsive ratiometric fluorescent probe 1 with multiple acetyl-ester sites was constructed for N2H4 and ammonia (Figure 1). Ammonia gave green emission at 487 nm, whereas N2H4 triggered yellow fluorescence at 543 nm for visual differentiation. The probe reached hydrazine-sensing equilibrium within 40 min, with a limit of detection (LOD) of 0.26 μM. Mechanistic studies indicated that N2H4 cleaved one or two acetyl groups at 0–180 μM, while all four ester groups were broken down above 300 μM. Probe 1 was applied for N2H4 quantitation in tap-water and river-water samples with satisfactory recoveries [31]. In 2023, turn-on probe 2 exhibited negligible fluorescence due to suppressed ESIPT (Figure 1). Upon exposure to N2H4, probe 2 exhibited green fluorescence at 540 nm with a large Stokes shift of 191 nm. Response equilibrium was attained within 30 min, affording an LOD of 0.117 μM. Probe 2 allowed N2H4 quantitation in real-world water and various soil samples with good recoveries, as well as fluorescence imaging of exogenous N2H4 in living zebrafish [32].
Figure 1.
Chemical structures of probes 1–7.
Coumarin is another prevalent fluorophore with desirable functionality; satisfactory water solubility; and superior optical performance, including high photostability, bright emission, and high quantum yield, rendering it promising for N2H4 sensing [33,34,35]. In 2023, a turn-on probe 3 was constructed for N2H4 detection based on the ICT mechanism (Figure 1). Upon exposure to N2H4, probe 3 displayed cyan-blue emission at 474 nm. It attained response equilibrium in 30 min and delivered an LOD of 24 nM. In addition, probe 3 enabled N2H4 quantitation in deionized-, tap-, and river-water samples with satisfactory recoveries, as well as fluorescence imaging of exogenous N2H4 in living zebrafish [36].
Rhodamine and fluorescein are typical xanthene fluorophores with high quantum yields, favorable biocompatibility, and facile structural tunability for N2H4 sensing and bioimaging [37,38]. In 2026, a series of FRET-based ratiometric fluorescent probes 4–7 were constructed by combining coumarin (donor) and rhodol (acceptor) fluorophores with diverse acyl masking groups (Figure 1). Among them, probe 6 bearing n-butyryl group achieved desirable trade-off between hydrolytic stability and N2H4 reactivity. Hydrazine-induced deacylation regenerated rhodol acceptor and activated FRET, producing ratiometric fluorescence shift from 470 nm (coumarin donor) to 548 nm (rhodol acceptor), affording an LOD of 98 nM. Probe 6 enabled ratiometric imaging of exogenous N2H4 in HeLa cells and zebrafish. Furthermore, probe-loaded test strips combined with smartphone RGB analysis achieved on-site visual detection, and it also quantified N2H4 in real-world water samples [39].
Dicyanoisophorone, a common NIR-probe building-block with large Stokes shift, affords probes 8–11 with favorable imaging performance (Figure 2). In 2023, an NIR ratiometric probe 8 bearing two chlorine atoms on phenolic hydroxyl group was reported. Halogen substituent improved fluorescence efficiency and lowered pKa to fit physiological pH. Upon N2H4 treatment, it displayed an obvious emission redshift from 490 nm (cyan) to 660 nm (NIR), affording an LOD of 0.30 μM within 30 min. Probe 8 enabled exogenous N2H4 imaging in living HepG2 cells. Moreover, probe-immobilized silica-gel TLC plates visualized gaseous N2H4 down to 1 ppm, and it was applied for soil sample analysis [40]. In 2026, three ortho-bromo-modulated NIR turn-on probes, 9–11, were reported. Among them, probe 9 featured favorable conjugation (dihedral angle 39.38°) and, thus, slow N2H4 response, while di-brominated probe 11 (89.21°) suffered from severe spontaneous hydrolysis in solution and poor stability. By contrast, mono-brominated probe 10 (79.40°) achieved an optimal balance between chemical stability and N2H4-triggered deacetylation. Probe 10 exhibited intense 675 nm NIR emission with a large Stokes shift of 160 nm, reaching equilibrium in 12 min with an LOD of 31 nM. It visualized exogenous N2H4 in HeLa cells, MRC-5 cells, zebrafish, and mice. Moreover, it could monitor isoniazid-metabolized endogenous N2H4 in cellular systems and mouse liver–kidney tissues [41].
Figure 2.
Chemical structures of probes 8–11.
Cyanine and hemicyanine dyes constitute attractive fluorophores for the construction of NIR fluorescent probes. Featuring low photodamage to biospecimens, deep-tissue imaging capability, and effective suppression of autofluorescence background, these fluorophores are suitable for real-time visualization of N2H4 in living cells, tissues, and animal models (Figure 3) [42,43,44]. In 2022, an NIR turn-on probe 12 containing a sulfonic acid group was presented to improve aqueous compatibility. Due to the increased π-conjugation, this probe exhibited a major absorption peak at 606 nm and weak fluorescence at 735 nm. Hydrazine incubation drastically amplified the 735 nm emission, concomitant with a discernible solution chromatic shift from dark-blue to cyan. Response equilibrium was accomplished within 15 min, affording an LOD of 82 nM (2.58 ppb) [45]. In the same year, a sulfur heteroatom-substituted turn-on probe 13 was constructed, which effectively widened Stokes shift to 158 nm (λem = 803 nm/λabs = 645 nm) after exposure to N2H4. Equilibrium was attained in about 15 min with an LOD of 0.23 μM [46]. Probes 12 and 13 achieved exogenous N2H4 imaging in live HepG2 and HeLa cells, respectively, as well as N2H4 quantitation in various aqueous matrices with satisfactory recoveries. Meanwhile, probe-12-based test strips permitted facile naked-eye on-site detection of gaseous N2H4.
Figure 3.
Chemical structures of probes 12 and 13.
In 2022, an ICT-based ratiometric fluorescent probe 14 was developed for N2H4 detection (Figure 4). Benefiting from the pyridinium cation moiety, probe 14 displayed a maximum emission at 595 nm with a large Stokes shift of 230 nm. In the presence of N2H4, ester cleavage led to a hypsochromic emission shift from 595 nm to 447 nm. This probe accomplished rapid response within 40 s and an LOD of 48 nM. Probe 14 enabled N2H4 quantitation in various environmental water and soil samples. Electrospun nanofibrous membranes loaded with 14 were further fabricated for portable visual detection of gaseous N2H4 assisted by smartphone RGB analysis. Moreover, it achieved ratiometric fluorescence imaging of exogenous N2H4 in live HeLa cells and Arabidopsis thaliana root tissues [47]. Reported in 2023, ICT-governed NIR turn-on fluorescent probe 15 displayed pronounced fluorescence enhancement at 692 nm upon hydrazine treatment, with a Stokes shift of 104 nm and equilibrium achieved within 12 min (LOD = 0.25 μM) (Figure 4). Accompanied by a visible solution color transition from purple to light blue, Probe 15 was fabricated into test strips for naked-eye visual detection of gaseous N2H4. It was further applied in quantitatively detecting trace N2H4 in water samples and mice samples, as well as real-time in vivo fluorescence imaging of N2H4 in mouse models [48]. In 2026, an NIR fluorescent probe 16 was engineered by introducing long polyethylene glycol (PEG) chains to improve aqueous solubility and reinforce the ICT effect (Figure 4). Upon exposure to hydrazine, probe 16 exhibited prominent NIR fluorescence enhancement at 714 nm, together with a large Stokes shift of 187 nm and a visible solution color transition from purple to light blue. The probe achieved rapid response within only 30 s and afforded an LOD of 0.13 μM. With mitochondrial targeting capability, probe 16 visualized exogenous hydrazine in living HeLa cells and isoniazid-derived endogenous hydrazine in HepG2 cells. Moreover, its corresponding test strips permitted naked-eye gaseous hydrazine detection, and satisfactory recoveries were obtained for hydrazine quantitation in practical water samples [49].
Figure 4.
Chemical structures of probes 14–19.
As representative ICT fluorophores, naphthalimide derivatives are widely adopted for N2H4 fluorescent sensing due to high photostability, large Stokes shift, favorable fluorescence quantum yields, and satisfactory pH tolerance [50,51]. In 2023, three dual-functional ratiometric probes, 17–19, were constructed, which displayed distinct sensing behaviors toward both N2H4 and esterase activity due to different steric and electronic effects of acyl substituents (Figure 4). Probe 18, equipped with a sterically hindered cyclohexanecarbonyl ester, demonstrated the best comprehensive performance, which yielded red-shifted emission with a 15-fold ratio enhancement (I571/I466) within 50 min alongside favorable photostability. Test strips loaded with probe 18 realized naked-eye discrimination of both liquid-phase and gaseous N2H4, accompanied by a fluorescence color transition from blue to yellow [52].
In 2025, a mitochondria-targeted dual-response probe 20 was developed for N2H4 detection via combined ICT and ESIPT mechanism (Figure 5). Hydrazine triggered a ratiometric blue-shifted fluorescence transition from 586 nm to 514 nm, yielding an LOD of 2.69 μM within a 1 h reaction period. Beyond hydrazine sensing, probe 20 exhibited additional responsiveness toward phosgene via acylation-induced fluorescence quenching at 586 nm. This probe enabled ratiometric imaging of isoniazid-generated endogenous mitochondria N2H4 in HepG2 cells, as well as N2H4 imaging in zebrafish and Arabidopsis thaliana roots. Moreover, probe 20-immobilized test strips allowed visual detection of gaseous N2H4, and the probe was applied for N2H4 quantitation in various practical water samples [53].
Figure 5.
Chemical structures of probes 20–22.
2-(2′-Hydroxyphenyl)benzothiazole (HBT) is a prevalent ESIPT fluorophore with favorable photostability and a large Stokes shift [54]. In 2027, ratiometric probe 21 was constructed based on N2H4-induced ester cleavage, which triggered a distinct fluorescence redshift from 506 nm to 613 nm with a large Stokes shift of 223 nm (Figure 5). The probe reached response saturation within 15 min and an LOD of 33 nM, realizing hydrazine quantitation in practical soil samples. Moreover, probe 21 was fabricated into test-strip and agarose-hydrogel portable sensing platforms for naked-eye visualization of both liquid and gaseous N2H4 assisted by smartphone RGB analysis. It further realized ratiometric imaging of both exogenous N2H4 and isoniazid-metabolized endogenous N2H4 in HeLa cells and zebrafish larvae, as well as N2H4 bioimaging in Arabidopsis thaliana roots [55].
In 2025, a benzopyranium-based probe 22 reacted with N2H4 to produce an 11-fold enhancement of red fluorescence at 643 nm alongside a visible solution color transition from purple to blue (Figure 5). The sensing reaction attained equilibrium within 30 min with an LOD of 81 nM, enabling N2H4 quantitation in diverse practical water samples. This probe also allowed imaging of both exogenous and isoniazid-metabolized endogenous N2H4 in HepG2 cells, as well as N2H4 imaging in zebrafish. In addition, electrospun PVB nanofibrous membranes embedded with probe 22 were fabricated for portable naked-eye detection of liquid-phase N2H4 with quantitative readout assisted by smartphone RGB analysis [56].
In 2025, a turn-on fluorescence probe 23 was developed for N2H4 sensing (Scheme 2). Unlike conventional ICT or ESIPT-based ester-cleavage probes, its sensing mechanism relies on N2H4-triggered acetyl ester hydrolysis, which restores intramolecular hydrogen bonding (IMHB) and subsequently activates the AIE effect. Upon N2H4 treatment, probe 23 underwent ester cleavage and IMHB cascades, producing a prominent 23-fold green fluorescence enhancement at 500 nm. The probe achieved rapid response within 2 min and an LOD of 0.43 μM. It was also successfully applied for N2H4 quantitation in tap-water, soil, pork, cabbage, and fish samples with satisfactory recoveries [57].
Scheme 2.
Chemical reaction of probe 23 with N2H4.
2.1.2. (Hetero)aroyl Ester as the Recognition Moiety
Apart from acetyl-caged phenolic esters, (hetero)aroyl-caged counterparts, including benzoyl, thiophene-2-carbonyl, picolinoyl, and others, also serve as efficient recognition motifs for N2H4.
In 2024, three turn-on fluorescence probes, 24–26, bearing varied benzoyl groups were developed, among which the pentafluorobenzoyl-caged probe 26 exhibited optimal sensing performance toward N2H4 (Figure 6). Hydrazine-initiated nucleophilic acyl substitution regenerated the parent fluorophore and restored ESIPT- and AIE-active emission at 538 nm with a large Stokes shift of 183 nm. The reaction completed within 20 min, yielding an LOD of 93 nM. Mechanistic studies demonstrated that probe 26 possessed the largest HOMO–LUMO energy gap (4.014 eV) relative to probe 24 (3.175 eV) and probe 25 (3.467 eV), accounting for its higher reactivity towards N2H4. Additionally, probe 26 enabled detection of N2H4 in liquid and gaseous states, real water and soil samples, alongside HeLa cells and latent fingerprint imaging [58]. Reported in 2026, turn-on probe 27 recovered the ESIPT effect upon N2H4 treatment and produced marked green fluorescence enhancement at 535 nm (Figure 6). It exhibited an initial response within 30 s and reached signal saturation after 20 min, affording an LOD of 71 nM. Probe 27 enabled reliable N2H4 quantification in spiked water and soil samples, as well as exogenous N2H4 bioimaging in living A549 cells [59].
Figure 6.
Chemical structures of probes 24–30.
In 2023, a coumarin-derived turn-on fluorescent probe 28 was developed adopting 2,4-dinitrobenzoate (DNB) as the recognition motif (Figure 6). The electron-deficient nature of nitro-substituted DNB rendered it susceptible to nucleophilic attack by N2H4, which restored the ICT effect and generated strong blue fluorescence enhancement at 461 nm. The sensing reaction reached equilibrium within 2 min, delivering an LOD of 35 nM. Probe 28 realizes multi-scenario hydrazine detection, including paper strips for gaseous N2H4 visualization; solution-phase N2H4 analysis in soil, food, and water matrices; and bioimaging of exogenous and isoniazid-metabolized endogenous N2H4 within HeLa and onion epidermal cells [60].
In 2026, an ICT-based turn-on fluorescence probe 29 functionalized with long PEG chain was developed (Figure 6). Hydrazine stimulation triggered a nearly 20-fold red fluorescence enhancement at 626 nm. The probe achieved an ultrafast response within 15 s and an LOD of 0.04 μM. Benefiting from these merits, it enabled naked-eye visual detection of liquid-phase N2H4, quantitation of N2H4 in real water samples, and exogenous N2H4 imaging in living HeLa cells [61]. Similarly, a quinoline-derived turn-on probe 30 employed DNB as the recognition site (Figure 6). In the presence of N2H4, the parent fluorophore 30-OH was regenerated, simultaneously switching off the ICT state and activating the AIE effect to produce strong green fluorescence enhancement at 582 nm. The sensing system attained equilibrium within 3 min with an LOD of 55 nM. Probe 30 was fabricated into test strips combined with smartphone RGB analysis for visual detection of gaseous N2H4 and enabled AND-logic gate operation. Moreover, it achieved N2H4 quantitation in diverse food and water samples, alongside bioimaging of exogenous and isoniazid-metabolized endogenous N2H4 in living HeLa cells and mice [62].
In 2022, two NIR turn-on fluorescent probes, 31 and 32, were constructed using thiophene-2-carbonyl as the recognition group (Figure 7). Probe 32, featuring an extended π-conjugated framework, displayed red-shifted emission at 664 nm upon N2H4 addition, together with a distinct color transition from light green to red. The reaction achieved saturation within 7 min and yielded an LOD of 8.7 ppb. Probe 32 was further utilized to in situ visualize the dynamic metabolic conversion of isoniazid into N2H4 in HepG2 cells and zebrafish [63]. Reported in 2023, a resorufin-based turn-on probe 33 exhibited a 45-fold fluorescence enhancement at 590 nm after N2H4 treatment, accompanied by an orange-to-pink color change (Figure 7). The sensing reaction reached saturation within 120 min with an LOD of 260 nM. Besides N2H4 quantitation in real-world water samples, probe 33 realized N2H4 bioimaging in living HepG2 cells, zebrafish, and mice [64].
Figure 7.
Chemical structures of probes 31–33.
Beyond conventional deprotection-based sensing strategies, emerging recognition mechanisms have been continuously explored. In 2023, an NIR ratiometric fluorescent probe 34 was fabricated with a picolinoyl ester reactive site (Scheme 3). Benefiting from a unique hydrogen bond-anchored sensing strategy, the pyridyl unit of picolinoyl group captured N2H4 via intermolecular hydrogen bonding, which spatially anchored and oriented N2H4 to facilitate efficient 6-exo intramolecular nucleophilic attack on the ester carbonyl group. Such synergistic mechanism endowed probe 34 with excellent N2H4 reactivity and selectivity, producing a prominent ratiometric fluorescence transition from 545 nm to 666 nm along with visible color variation. The sensing reaction completed within 10 min, delivering an LOD of 9.81 nM (0.3 ppb). Probe 34 was capable of visualizing both exogenous and isoniazid-metabolized endogenous N2H4 in living HepG2 cells [65].
Scheme 3.
Reaction process of probe 34 for detecting N2H4.
In 2025, a turn-on fluorescent probe 35 was constructed by linking dicyanoisophorone and coumarin skeletons through an ester bond (Scheme 4). The intact probe exhibited weak fluorescence due to PET effect associated with the ester bond. Hydrazine-induced ester cleavage released two highly fluorescent molecules and produced turn-on emission at 643 nm with a Stokes shift of 215 nm. The reaction reached fluorescence saturation in 100 min with an LOD of 0.40 μM. This probe enabled N2H4 detection in complex matrices, including environmental water, soil, rice, lemon, bean sprouts, and Arabidopsis thaliana roots, alongside bioimaging in living cells [66].
Scheme 4.
Chemical reaction of probe 35 with N2H4.
2.1.3. Cinnamoyl Ester as the Recognition Moiety
Cinnamoyl-caged phenolic ester can serve as efficient recognition moieties for hydrazine, operating via a sequential 1,4-nucleophilic addition/tautomerization/cyclization/elimination cascade (Scheme 1b).
In 2024, a colorimetric and turn-on fluorescence probe 36 was developed with cinnamoyl-caged phenolic ester as the recognition moiety (Figure 8). Hydrazine-triggered cleavage of the cinnamate ester restored the ICT effect, producing intense yellow turn-on fluorescence at 556 nm, alongside a distinct color transition from colorless to bright yellow. The reaction reached equilibrium within 4 min and afforded an LOD of 0.29 μM. Probe 36 enabled N2H4 quantitation in diverse water and soil matrices, as well as N2H4 bioimaging in living HepG-2 cells and zebrafish. Furthermore, probe 36-loaded paper test strips allowed real-time naked-eye detection of N2H4 under both aqueous and vapor phases [67]. In the same year, a mitochondria-targeted NIR turn-on probe 37 adopted a cinnamoyl masking group to suppress the ESIPT effect and yield weak background emission (Figure 8). Hydrazine-mediated cleavage of the cinnamoyl moiety activated both ESIPT and ICT pathways, generating an approximately 20-fold fluorescence enhancement at 685 nm with a large Stokes shift of 171 nm. The probe reached signal saturation within 3 min and provided an LOD of 0.11 μM. It supported multi-scenario N2H4 detection, including paper strips coupled with a smartphone RGB dual-mode platform for gaseous N2H4 visualization; solution-phase analysis in sewage, soil, and mung-bean samples; and bioimaging of exogenous and isoniazid-metabolized endogenous N2H4 in living HeLa cells [68]. A red-emitting turn-on fluorescent probe 38 containing a positively charged oxonium ring was engineered for aqueous N2H4 detection (Figure 8). Upon N2H4 exposure, it exhibited a prominent red fluorescence enhancement at 625 nm, achieving a response within 30 s and an LOD of 63 nM. This probe quantified N2H4 in multiple river-water samples and realized exogenous N2H4 imaging in living HeLa cells, onion epidermal tissues, and zebrafish [69].
Figure 8.
Chemical structures of probes 36–38.
2.1.4. 4-Bromobutyryl Ester as the Recognition Moiety
Apart from the above ester recognition motifs, aliphatic halogen-substituted acyl groups exemplified by 4-bromobutyryl ester also serve as efficient hydrazine-responsive cleavage sites. Unlike common ester-cleavage pathways, the sensing event follows a sequential SN2 nucleophilic substitution/cyclization/elimination cascade initiated by N2H4.
In 2023, probe 39 underwent N2H4-mediated deprotection to regenerate phenolic hydroxyl group and activate ESIPT, yielding ratiometric fluorescence shifting from 501 nm (cyan-blue) to 561 nm (bright green). It attains equilibrium in 17 min with an LOD of 0.184 μM (Figure 9) [70]. In the same year, two benzocoumarin-based chemodosimeters, 40 and 41, were constructed with 4-bromobutyrate and cinnamate ester recognition units, respectively (Figure 9). Hydrazine-triggered ester cleavage restored ICT process, generating turn-on green fluorescence at 528 nm and 532 nm, respectively. In terms of sensing performance, probe 40 reached signal saturation within 10 min with an LOD of 1.05 μM, while probe 41 required 30 min to reach equilibrium (LOD = 1.01 μM), demonstrating faster kinetics for the aliphatic haloacyl recognition site. Both probes supported N2H4 quantitation in real samples, paper-strip-based naked-eye visualization, and bioimaging in living cells [71].
Figure 9.
Chemical structures of probes 39–48.
In 2022, a rhodol-derived turn-on probe 42 was developed, which released rhodol fluorophore and produced prominent fluorescence enhancement at 565 nm in the presence of N2H4 (Figure 9). The sensing system reached saturation after 50 min of incubation with an LOD of 0.64 μM. Probe 42 worked well for N2H4 quantitation in diverse water samples, as well as in situ fluorescence imaging of exogenous N2H4 in living MCF-7 cells and Arabidopsis thaliana roots [72].
In 2022, two NIR turn-on probes, 43 and 44, adopted 4-bromobutyrate and 2-bromoethyl formate ester as recognition groups (Figure 9). Both probes showed increased emission intensity at 640 nm upon exposure to N2H4, with probe 43 displaying a higher fluorescence enhancement. The LODs of probes 43 and 44 were 28 nM and 38 nM, respectively [73]. In 2026, a mitochondria-targeted probe 45 produced red-shifted absorption and amplified NIR emission at 730 nm toward N2H4 (Figure 9). The reaction reached saturation within 40 s and delivered an LOD of 16.2 nM. Paper strips loaded with probe 45 allowed portable N2H4 sensing assisted by smartphone-assisted RGB analysis. This probe also enabled fluorescence imaging of exogenous and isoniazid-metabolized endogenous N2H4 in living HepG2 cells and zebrafish [74].
In 2022, a HBT-based turn-on probe 46 with dual recognition sites reacted with N2H4 to activate ESIPT process, producing prominent green fluorescence enhancement at 480 nm with a large Stokes shift of 153 nm (Figure 9). Signal saturation was achieved within 35 min with an LOD of 0.1 μM. Probe 46 was applied for N2H4 measurement in environmental samples and living organisms [75]. In another sample, Levulinate ester was also utilized to fabricate probe for N2H4 detection, which gave a remarkable turn-on emission at 620 nm with a 122 nm Stokes shift and discernible color change [76]. Recently, two additional turn-on-type probes, 47 (LOD of 0.18 μM) [77] and 48 (LOD of 0.394 μM) [78], were constructed using 4-bromobutyrate as the recognition moiety (Figure 9).
Comparative Assessment of Ester Recognition
Ester-based probes show that response kinetics are dictated mainly by the electronic character of the masked acyl group. For example, the 4-bromobutyrate probe 40 responded in 10 min, whereas the cinnamate analogue 41 required 30 min with nearly identical LODs (1.05 and 1.01 μM) [71]. Among the acyl-masked FRET series 4–7, the n-butyryl derivative 6 offered the best balance between hydrolytic stability and reactivity (LOD 98 nM) [39]. Across recognition subgroups, electron-poor (hetero)aroyl esters react fastest: the DNB-caged coumarin 28 completed within 2 min (35 nM) [60] and the PEGylated aroyl probe 29 within 15 s (40 nM) [61]. Simple acetyl probes span a wide range, from 40 s for pyridinium probe 14 (48 nM) [47] and 2 min for AIE probe 23 [57] to 1 h for probe 20 [53]. The cinnamoyl cascade probes 36–38 require seconds to minutes [67,68], whereas the resorufin aroyl probe 33 responds sluggishly (120 min) [64]. The fluorophore governs the optical readout: coumarin and naphthalimide derivatives contribute brightness, water solubility and organelle targeting (probes 3, 17–19, and 20), hemicyanine and dicyanoisophorone scaffolds deliver NIR emission (probes 8–13 and 15), and the HBT-ESIPT scaffold 21 affords a large 223 nm ratiometric shift [55]. Halogen tuning in probes 8–11 shows that excessive activation sacrifices hydrolytic stability (di-brominated probe 11) [40,41]. Picolinoyl probe 34 demonstrates that hydrogen bond-anchored preorganization can effectively enhance the sensing performance (10 min, 9.81 nM) [65]. Sensitivity spans a roughly 270-fold range within this family: the lowest LODs belong to the picolinoyl 34 (9.81 nM), the DNB-caged coumarin 28 (35 nM) and the bromobutyrate 45 (16.2 nM), whereas the mitochondria-targeted acetyl ester 20 (2.69 μM), the halobutyrate pair 40/41 (1.05 and 1.01 μM), and the simple acetyl probes 1 and 2 (0.12–0.26 μM) are far less sensitive.
2.2. Cyano-Based Probes
Acrylonitrile derivatives, including malononitrile [79,80], benzothiazole-2-acetonitrile [81,82], ethyl cyanoacetate [83,84], and others [85], serve as promising recognition moieties for N2H4. These fragments are conjugated with aldehyde- or ketone-functionalized fluorophores via Knoevenagel condensation, affording D-π-A conjugated systems with prominent ICT character. Driven by strong electron-withdrawing effects, the resulting α,β-unsaturated C=C double bond is electrophilic and vulnerable to nucleophilic attack by N2H4. The subsequent addition–elimination reaction cleaves the recognition moieties and generates hydrazone-based products (Scheme 5). Such disruption of the π-conjugated framework suppresses the intrinsic ICT process, inducing pronounced blue-shifts in absorption and emission spectra, accompanied by perceptible colorimetric and fluorometric transitions (generally from red/orange to green/blue). Accordingly, these building blocks are widely adopted to construct highly selective N2H4 fluorescent probes.
Scheme 5.
Reaction process based on cyano probes.
2.2.1. Malononitrile as the Recognition Moiety
Among the cyano-containing probes, dicyanovinyl-based probes have garnered considerable attention due to their straightforward design and robust reactivity toward N2H4.
A series of acrylonitrile-based fluorescent probes, 49–54, have been developed for N2H4 detection with diversified sensing performances and applications (Figure 10). In 2023, three NIR ratiometric probes, 49–51, were constructed. Probe 49 exhibited AIE emission at 664 nm. Upon reaction with N2H4, the ICT process was inhibited and new blue-green fluorescence appeared at 467 nm. Probes 49–51 reached full reaction saturation at 110 min, 110 min, and 90 min, with LODs of 1.51 μM, 0.54 μM, and 2.61 μM, respectively [86]. In 2025, ratiometric probe 52 displayed an orange-red-to-light-blue fluorescence transition with 392-fold enhancement at 510 nm, completing its sensing reaction within 22 min with an LOD of 0.408 nM [87]. In 2027, dual-mode probe 53 underwent N2H4-triggered nucleophilic attack to disrupt intrinsic ICT, giving colorimetric and ratiometric responses with emission blue-shifting from 623 nm to 510 nm. Probe 53 delivered an ultrafast response (<5 s), an LOD of 42 nM, and stable performance over pH 1–12 [88]. In 2023, AIE-ICT dual-functional turn-on probe 54 exhibited orange-red AIE effect and produced cyan turn-on fluorescence at 468 nm toward N2H4, reaching a plateau in 20 min with an LOD of 0.196 μM (6.25 ppb). Cyanide-induced spectral interference was experimentally confirmed for probe 54 [89]. Practically, probes 49–54 were applied for bioimaging in living cells and zebrafish, portable solid-state sensing platforms (test strips, electrospun polyurethane films, and cotton swabs), and N2H4 quantitation in real-water samples, as well as a smartphone-assisted RGB readout platform. As a distinctive functional expansion, probe 53 enabled sequential response toward N2H4 and Cu2+ to achieve the construction of molecular sequential logic gates and ternary fluorescence encoding systems.
Figure 10.
Chemical structures of probes 49–58.
Apart from triphenylamine-based probes, other fused heterocyclic aromatics, such as carbazole [90,91,92], phenothiazine [80], and phenoxazine [93], have also been exploited for N2H4 detection (Figure 10). In 2024, AIE-active fluorescent probe 55 emitted yellow-green fluorescence at 568 nm in nearly 100% aqueous media. Hydrazine rapidly quenched its fluorescence within 40 s. This probe exhibited an LOD of 6.3 nM, and enabled N2H4 imaging in HeLa cells, mung-bean sprouts, and Arabidopsis thaliana. Test strips loaded with probe 55 realized colorimetric detection of aqueous and gaseous N2H4, and the probe quantifies N2H4 in soil, serum, urine, food, and beverage samples [90]. In 2025, carbazole-xanthene-based turn-on probe 56 showed weak fluorescence originating from the ICT effect. Reaction with N2H4 generated strong yellow fluorescence at 565 nm within 80 s, with an LOD of 1.26 μM. Fabricated into swab-based sensors and PVA films, probe 56 supported on-site visual detection of liquid and vapor N2H4. Combined with smartphone RGB analysis, it quantified N2H4 in environmental water, soil and plant samples [91]. In 2026, indoloquinoline-based probe 57 displayed turn-off quenching of red fluorescence at 615 nm upon N2H4 exposure. With a response time of 2 min and an LOD of 0.68 μM, it enabled in vitro N2H4 detection and real-time fluorescence imaging in MCF-7 tumor-bearing nude mice [92]. In 2024, phenoxazine-based ratiometric fluorescent probe 58 (LOD of 17.1 nM) produced a distinct fluorescence blue-shifted from 633 nm to 487 nm within 14 min. It permitted N2H4 quantification in water, soil, and food matrices, as well as bioimaging in HeLa cells and zebrafish [93].
Malononitrile has also been integrated with diverse fluorophore skeletons to construct N2H4-responsive fluorescent probes (Figure 11). In 2022, bithiazole-based turn-off fluorescent probe 59 carried a phenolic hydroxyl group for ERα-targeting capability. The probe itself exhibited intense NIR emission at 676 nm, and N2H4 induced pronounced fluorescence quenching accompanied by a 143 nm blue shift. The maximum spectral response is attained within 3 min with an LOD of 16.6 nM. Owing to ERα-binding affinity and low cytotoxicity, probe 59 preferentially accumulated in ERα-positive MCF-7 breast-cancer cells, permitting N2H4 detection in vitro and intratumoral N2H4 imaging in MCF-7 tumor-bearing nude mice [94]. In 2024, probe 60 adopted tetraaryl imidazole as the AIE scaffold and utilized the twisted intramolecular charge-transfer (TICT) effect for sensitive turn-on N2H4 recognition. It had an LOD of 33.8 nM and reached spectral equilibrium within 30 min. Probe 60 was applied for N2H4 detection in water samples and living cells, and fabricated into portable test strips for visual N2H4 sensing [95]. In 2023, solvatochromic quinoline-derived probe 61 exhibited fluorescence quenching at 563 nm upon N2H4 treatment. Signal saturation occurred within 21 min with an LOD of 0.58 μM. Paper-strip sensors based on probe 61 supported on-site visual monitoring of N2H4 in water, vapor and soil matrices, alongside bioimaging in C6 glioma cells [96]. In 2025, NIR 2H-chromene-based ratiometric probe 62 exhibited a large 171 nm blue shift from 652 nm to 481 nm upon reaction with N2H4. Signal saturation was attained within 20 s with an LOD of 53 nM. This probe was fabricated into portable test strips and protective coats for rapid on-site visual monitoring of liquid and gaseous N2H4 [97]. In 2026, diketopyrrolopyrrole-based turn-on fluorescent probe 63 exhibited aggregation-caused quenching (ACQ) in aqueous media. Hydrazine suppressed ICT process and enhanced fluorescence at 625 nm. With an LOD of 28.52 nM and a fast response of around 35 s, probe 63 achieved N2H4 imaging in soil, vegetables, Arabidopsis thaliana, living cells, and zebrafish [98]. In the same year, dithienothiophene-based turn-off probe 64 displayed N2H4-triggered fluorescence quenching at 593 nm. It reached sensing equilibrium within 10 min with an LOD of 0.129 μM and maintained stable spectral output over pH 1–13. Coupled with smartphone-assisted RGB analysis, it realized instrument-free on-site N2H4 quantification [99]. At the same time, benzothiadiazole-based turn-off probe 65 produced obvious fluorescence quenching at 508 nm after reaction with N2H4. The response completes within 20 min and the LOD is 0.023 μM. Fabricated into test strips and combined with smartphone RGB imaging, it allowed on-site quantitative analysis, gaseous/liquid hydrazine detection and tracking of hydrazine degradation in soil [100]. In 2024, coumarin-derived ratiometric fluorescent probe 66 generated I504/I560 signal variation toward N2H4, finishing spectral response in 30 min with an LOD of 2.04 μM [101]. In 2025, cyanostilbene-derived probe 67 with similar AIE properties displayed turn-on fluorescence enhancement response upon N2H4 exposure [102].
Figure 11.
Chemical structures of probes 59–67.
Besides ICT mechanism, ESIPT-activated zero-background probe 68 responded with N2H4 to initiate ESIPT process and produced turn-on blue-green fluorescence at 463 nm (Figure 12). Systematical studies revealed that ortho-hydroxyl group served as a proton donor to form intramolecular hydrogen-bonding for ESIPT activation. Among probe 68–70, para-bromo substitution is also indispensable, which increased electrophilicity of the dicyanovinyl moiety to facilitate nucleophilic attack by N2H4. Probe 68 achieved an ultrafast 1 s response with an LOD of 0.46 nM and strong anti-interference capability [103]. In 2025, pyrene-based sensor 71 enabled discrimination between hydrazine and hydrogen sulfide via distinct reaction pathways and ratiometric fluorescence responses. Specially, N2H4 triggered azine formation, creating a new emission peak at 458 nm while quenching the original 540 nm band. This probe delivered an ultrafast 5 s response and an LOD of 11.98 nM. The in situ generated azine further enabled sequential detection of Cu2+ (turn-on) and subsequent H2S (turn-off) through metal-complexation and demetallation process [104].
Figure 12.
Chemical structures of probes 68–71 and sequential reaction process of probe 71 with different analytes.
2.2.2. Benzothiazole-2-acetonitrile as the Recognition Moiety
Apart from arylidene malononitrile, 2-benzothiazoleacetonitrile serves as another recognition motif for N2H4, yielding ratiometric (Figure 13, 72–77) [105,106,107,108,109,110], turn-on (Figure 14, 78–80), and turn-off (Figure 15, 81,82) fluorescent probes. In recent years, a variety of such probes have been developed with diverse fluorophore skeletons and distinct design merits.
Figure 13.
Chemical structures of probes 72–77.
Figure 14.
Chemical structures of probes 78–80.
Figure 15.
Chemical structures of probes 81 and 82.
In 2025, two mitochondrial-targeting coumarin-based probes, 72 and 73, both exhibited an emission blue-shift larger than 100 nm toward N2H4. Probe 72 showed spectral variation from 615 nm to 513 nm (LOD 0.10 μM, 30 min), whereas probe 73 displayed an emission shift from 635 nm to 521 nm (LOD 0.09 μM) [106]. Phenanthroimidazole-based D-π-A probe 74 displayed a distinct fluorescence transition from orange (620 nm) to blue (442 nm), delivering an LOD of 81 nM with a large Stokes shift of 188 nm [107]. Distinguished by lipid droplet-targeting capability, NIR probe 75 operated under a dual-excitation/dual-emission mode. Hydrazine suppresses the ICT process, quenching the red fluorescence at 650 nm and enhancing blue fluorescence at 475 nm (LOD 2.093 nM, 90 min) [108]. Phenothiazine-based probe 76 was designed for dual discrimination of N2H4 and hypochlorous acid. In the presence of N2H4, a prominent blue-shift from 680 nm to 525 nm (red to green) was observed, yielding an LOD of 15 nM after 5 min incubation [109]. As a multi-analyte-responsive NIR chemodosimeter, probe 77 was capable of simultaneous recognition of N2H4, cyanide and hypochlorite. In response to N2H4, it produced a ratiometric fluorescence transition from far-red (750 nm) to turquoise-blue (485 nm) (LOD 0.065 μM, 5 min), and enabled the construction of various opto-chemical molecular logic gates within a single-molecule platform [110]. Collectively, most of these probes are compatible with smartphone-assisted RGB quantitation and solid-state TLC/test-strip platforms for vapor-phase N2H4 detection. They can perform fluorescence imaging in living cells and zebrafish, and many have been validated for N2H4 detection in practical samples such as water, soil, plant, and food matrices.
A xanthene-based dual-response turn-on fluorescent probe 78 was capable for discriminating N2H4 and hypochlorite. Hydrazine induced the formation of bright-yellow-emitting hydrazone, while hypochlorite triggered the generation of blue-fluorescent aldehyde, with LODs of 27 nM and 34 nM, respectively, and a rapid response within 20 s. Assembled into agarose-based hydrogel kits and coupled with smartphone RGB readout, probe 78 realized point-of-care visual quantitation of the two analytes in soil–water and food matrices, as well as intracellular fluorescence imaging in GL261 cells [111]. Two similar NIR fluorescent probes, 79 and 80, were designed for simultaneously detecting N2H4 and viscosity. Hydrazine-triggered substituent elimination produces hydrazone derivatives, suppresses the TICT effect, and thus induces significant fluorescence enhancement. Probe 79 afforded an LOD of 0.19 μM with spectral saturation at 120 min, while 80 exhibited superior performance with an LOD of 0.13 μM and saturation within 110 min. Both probes enable fluorescence imaging of N2H4 in HepG2 cells, zebrafish, and Arabidopsis thaliana [112].
Recently, two AIE-active probes, 81 [113] and 82 [114], were prepared based on diarylethene and tetraarylethylene, respectively, which led to fluorescence quenching at 540 nm and 565 nm toward N2H4 (Figure 15). Probe 81 achieved spectral saturation within 150 min with an LOD of 23 nM, while probe 82 reached equilibrium rapidly in 12 min with an LOD of 0.244 μM. Probe 81 possessed intrinsic photochromic behavior via reversible ring-opening/ring-closing isomerization upon alternate UV–visible light irradiation. In comparison, pristine 82 showed no photochromism. Its N2H4-generated intermediates TAE-B-1o and product TAE-B-2o possessed reversible photochromic properties. Both probes could be fabricated into test strips for smartphone-assisted RGB quantitative detection of gaseous N2H4. Practically, probe 81 enabled N2H4 fluorescence imaging in A549 cells and quantitative analysis of real water samples, and can serve as invisible encryption ink for anti-counterfeiting. Benefiting from the photoresponsive properties of its N2H4-reaction products, probe 82 realized N2H4 detection in complex soil matrices and supported the fabrication of dual-input dual-output molecular logic gates and time-resolved dynamic information encryption platforms.
2.2.3. Ethyl Cyanoacetate as the Recognition Moiety
Ethyl cyanoacetate, a versatile building block bearing both electron-withdrawing cyano and ester moieties, has been widely utilized for constructing fluorescent N2H4 probes (83–88) in recent years (Figure 16).
Figure 16.
Chemical structures of probes 83–88.
For example, a carbazole-based ratiometric colorimetric probe underwent structural rearrangement upon reaction with N2H4, inducing distinct blue-shifted ratiometric fluorescence variation from 535 nm to 445 nm, an LOD of 1.5 μM and response equilibrium achieved within 100 s [115]. Derived from natural tanshinone-IIA, another dual-excitation NIR ratiometric probe 83 suffered ICT suppression upon N2H4 addition, generating prominent blue-shifted fluorescence alteration with emission shifting from 630 nm to 469 nm. It afforded an LOD of 58 nM, achieving spectral equilibrium within 3 min [116]. Likewise, a phenanthroimidazole-based dual-response fluorescent probe 84 achieved dual-analyte discrimination toward N2H4 and bisulfite. Upon reaction with N2H4, probe 84 exhibited a blue-shifted ratiometric fluorescence change from yellow (590 nm) to green (530 nm), affording an LOD of 0.182 μM with rapid response plateaus at 55 s [117]. Probe 83 realized N2H4 fluorescence imaging in various biological models, including mammalian cells and zebrafish. Test strips of 83 offered qualitative visual detection of N2H4 vapor, with quantitation performed by solution-phase fluorescence. In comparison, probe 84 test strips achieved on-site N2H4 quantitation via RGB signals. Solution-based assays enabled probe 83 for food-matrix N2H4 detection, while probe 84 allowed N2H4 analysis in soil and bisulfite quantitation in food samples.
Apart from ratiometric sensors, turn-on-type probes based on this recognition scaffold have also been reported. For example, phenothiazine-based probe 85 produced prominent green fluorescence at 523 nm upon N2H4-triggered Schiff-base formation. It afforded an LOD of 0.15 μM and reached response saturation within 5 min. Probe 85 realized N2H4 fluorescence imaging in HeLa cells. Its test-strip platform enabled visual qualitative detection of N2H4 vapor, while solution-phase measurements permitted N2H4 quantitation in water and soil samples [118]. In 2026, an HBT-based dual-mode colorimetric turn-on probe 86 was reported. Upon exposure to N2H4, the intrinsic ICT process was disrupted, generating fluorescence enhancement at 505 nm together with a yellow-to-colorless visual color change, delivering an LOD of 8.27 μM. In the agarose-hydrogel solid-state system, detectable signal appeared within 1 min and remained stable for 30 min upon N2H4 addition. Probe 86 was incorporated into agarose hydrogel to build a smartphone-RGB-assisted platform for instrument-free on-site detection. Additionally, it could be formulated as security ink to fabricate N2H4-responsive anti-counterfeiting patterns on filter paper [119]. Recently, a deep-red dual-responsive probe 87 for discriminative sensing of N2H4 and peroxynitrite displayed an emission hypsochromic shift from 672 nm to 514 nm toward N2H4, with an LOD of 0.13 μM and 80 min required for full saturation. It permitted N2H4 fluorescence imaging in HepG2 cells, zebrafish, and barley root tips, as well as N2H4 quantitation in food and environmental water samples [120].
The reactive ethyl cyanoacetate recognition unit can also produce turn-off fluorescence outputs upon analyte binding. Naphthalene-based chemodosimeter 88 served as a representative example. Upon nucleophilic reaction with N2H4, it displayed distinct blue-shifted fluorescence quenching together with a ~20 nm blue-shift of emission maximum, delivering an LOD of 3.077 nM and reaching response saturation within 3 min. Beyond quantitative detection in environmental water and soil extracts, probe 88 could be fabricated into black-paper and TLC-based test strips to realize visual on-site monitoring of N2H4 vapor [121].
It has been proven that the terminal recognition moiety can greatly tune the N2H4-sensing behavior of fluorescent probes (Figure 17). In 2023, three naphthalene-derived D-π-A probes, 89–91, with varied electron-withdrawing acceptors were screened for N2H4. Only malononitrile-substituted 89 exhibited prominent blue-shifted ratiometric fluorescence change from 518 nm to 485 nm, affording an LOD of 0.3 μM within 3 min. In comparison, ethyl-2-cyanoacetate-based probe 90 showed negligible fluorescence response, and malonate-functionalized probe 91 showed virtually no spectral variation. DFT calculations confirmed this discrepancy originated from the descending electron-withdrawing capacity of the terminal acceptors. Probe 89 achieved N2H4 quantitation in water–soil matrices, as well as fluorescence imaging in Arabidopsis root tissues and zebrafish embryos. Moreover, paper-based test strips combined with smartphone RGB readout allowed portable on-site quantitative detection of N2H4 [122]. Similarly, two imidazole analogues, 92 and 93, were prepared with distinct Michael-acceptor recognition moieties. Both probes exhibited N2H4-triggered fluorescence quenching and blue-shifted emission, delivering an LOD of 0.08 ppb for probe 92. Nevertheless, probe 93 displayed inferior anti-interference capability against amines, owing to the weaker electron-accepting strength of ethyl cyanoacetate. Beyond solution and gel-state detection, probe 92-based polymer films realized the monitoring of N2H4 vapor leakage. It also enabled intracellular N2H4 imaging in C6 glioma cells [123].
Figure 17.
Chemical structures of probes 89–93.
2.2.4. Other Cyano-Based Structures as the Recognition Moiety
Besides the above Michael acceptors, pyridineacetonitrile represents another promising recognition moiety for N2H4 (Figure 18). A water-soluble coumarin-based dual-responsive turn-on probe 94 achieved simultaneous detection of N2H4 and viscosity via independent optical channels. Nucleophilic attack by N2H4 induced green-channel fluorescence enhancement with an LOD of 0.135 μM, while high-viscosity environments suppressed intramolecular rotation and amplified red-channel fluorescence. Immobilized on TLC plates, the probe enabled dual-mode colorimetric-fluorescent visualization of N2H4 vapor and distinguished living and dead 4T1 tumor cells based on difference in intracellular viscosity [124]. In 2026, a nopinone-derived biphenyl tetrahydroindazole probe 95 operated as a turn-off chemodosimeter for N2H4. It exhibited obvious fluorescence quenching at 520 nm and reached spectral equilibrium within 30 min, with an LOD of 74.5 nM. Besides quantifying N2H4 in environmental water, soil, and food matrices, sensor 95 could be fashioned into filter-paper swabs for portable visual readout of liquid and vapor-phase N2H4. The probe permitted N2H4 fluorescence imaging in HeLa cells, onion epidermal cells, and zebrafish models [125].
Figure 18.
Chemical structures of probes 94 and 95.
Large-conjugated pyrrolopyrrole aza-BODIPY fluorophores feature high quantum yields, as well as NIR absorption and emission properties. In 2022 and 2026, aza-BODIPY-based turn-on fluorescent probes 96 and 97 have been prepared for N2H4 detection (Figure 19). Windmill-shaped probe 96 displayed AIE characteristics, with absorption and emission maxima at 751 nm and 825 nm, respectively. Hydrazine triggered synergistic cleavage of acrylonitrile and B-N bonds in probe 96, inducing large hypsochromic shifts of 198 nm in absorption and 173 nm in emission. This probe achieves ratiometric turn-on fluorescence response within 3.5 min with an LOD of 0.075 μM. Owing to its twisted 3D conformation, probe 96 exhibited a reaction rate 79.3-fold higher than its planar counterpart. Fabricated into PMMA polymer films, the sensor enabled dual colorimetric and fluorescent visualization of gaseous N2H4 and realized N2H4 quantitation in tap- and lake-water samples [126]. On the other hand, probe 97 demonstrated discriminative detection of N2H4 and hydrogen sulfide, producing turn-on emission at 574 nm for hydrazine, with an LOD of 2.38 nM and a response time of 8 min. Integrated onto polyamide thin films or polyurethane sponges and combined with smartphone RGB analysis, probe 97 enabled portable semi-quantitative visual screening for both liquid and gaseous analytes. Practical quantification was successfully demonstrated across diverse real-world matrices, including water, soil, flowers, red wine, beer, and grain-derived food samples [127].
Figure 19.
Chemical structures of probes 96 and 97.
Comparative Assessment of Cyano Activated Recognition
Here, the reactive unit is the activated conjugated C=C bond, whose reactivity is set mainly by acceptor electronics. In the naphthalene series 89–93, only the malononitrile derivative 89 responds appreciably (3 min, 0.3 μM), whereas ethyl cyanoacetate 92 and malonate 93 stay nearly silent owing to decreased electron-withdrawing ability [122]. Likewise, para-bromo activation is essential for the ultrafast ESIPT probe 68 (1 s, 0.46 nM) among 68–70 [103]. Within the same acceptor class, response rate also spans four orders of magnitude, from 1 s (probe 68 [103]), 20 s (xanthene 78, 27 nM) [111] and 40 s (AIE carbazole 55, 6.3 nM) [90], through 3 min (probes 83 and 88 [116,121]), to 90–110 min for the NIR ratiometric probes 49–51 [86] and 150 min for photochromic probe 81 [113]. The twisted aza-BODIPY 96 reacts about 80-fold faster than its planar counterpart, showing that conformation should also be considered sometimes [126]. Fluorophore effects are equally distinct: AIE/TICT scaffolds (probes 55, 60, 67, 81, and 82) support aqueous and solid-state outputs and phenothiazine/xanthene members allow dual N2H4/HClO discrimination (probes 76, 78, 85). Strong acceptors promote initial red/NIR emission but blue-shift the product, so an NIR-emissive probe does not guarantee an NIR analytical signal. In some examples, electrophilicity also invites interference (cyanide for probe 54 [89], amines for probe 93 [123]). LODs span four orders of magnitude, from 0.41 nM (52), 0.46 nM (68) and 2.1–3.1 nM (75, 88) through 6.3–81 nM for most malononitrile (55, 58–60, 62, and 63) and benzothiazole-2-acetonitrile members (74, 81) to 1.26–8.27 μM for the least sensitive members (49, 51, 56, 66, and 86).
2.3. Cyclic 1,3-Diketones-Based Probes
Cyclic 1,3-diketones derivatives, including 1,3-indandione, (thio)barbituric acid, and Meldrum’s acid, serve as promising recognition moieties for N2H4. Analogous to cyano-based probes, these moieties are conjugated with aldehyde- or ketone-functionalized fluorophores through Knoevenagel condensation, constructing D-π-A conjugated systems with prominent ICT characteristics. The electrophilic α,β-unsaturated C=C bond undergoes N2H4-triggered addition–elimination reaction, which cleaves the diketone recognition group and yields hydrazone products (Scheme 6). Therefore, cyclic 1,3-diketone scaffolds are widely utilized to develop high-selectivity N2H4 fluorescent probes.
Scheme 6.
Reaction process based on cyclic 1,3-diketones probes: (a) 1,3-Indandione; (b) (Thio)barbituric acid.
2.3.1. 1,3-Indandione as the Recognition Group
Adopting 1,3-indandione as the recognition acceptor, a series of D-π-A probes have been reported, including ratiometric (98–100), turn-on (102–104), and turn-off (105) ones (Figure 20).
Figure 20.
Chemical structures of probes 98–105.
NIR probe 98 utilized benzothiazole as the electron-donating fluorophore and exhibited combined ESIPT-ICT photophysical behavior. Hydrazine triggered cleavage of the 1,3-indandione moiety to disrupt the ICT effect, producing ratiometric fluorescence conversion from red (680 nm) to green (510 nm). It achieved an LOD of 1.29 μM with a fast 2 min response and stable ratiometric signals across pH window of 2.0–10.0 [128]. Ratiometric probe 99 was built on a naphthalene scaffold, delivering a large 230 nm blue shift, with original 670 nm red emission decaying and new blue-green fluorescence emerging at 440 nm. The probe afforded an LOD of 0.5 μM and 18 min signal saturation [129]. Probe 100 was a carbazole–pyrimidine chemodosimeter, where the pyrimidine unit is critical for N2H4 recognition. Hydrazine-induced cleavage interrupted the original carbazole to indanedione ICT and established a new ICT channel between carbazole and pyrimidine, producing a 136 nm blue shift from 621 nm to 485 nm. This sensor delivered an LOD of 0.169 μM and achieved signal equilibrium within 30 s. Control probe 101 lacking pyrimidine moiety showed negligible spectral alternation [130]. These sensors permitted visual identification of liquid and gaseous N2H4, as well as quantitative detection in water and soil samples. Solid-state platforms ranging from cotton swabs, TLC strips to electro-spun nanofibrous membranes supported smartphone-RGB quantitative readouts. Biologically, they achieved intracellular ratiometric N2H4 imaging, and some worked in zebrafish, onion tissues, and Arabidopsis thaliana.
Turn-on probe 102 utilized phenoxazine as the electron-donating fluorophore and exhibited prominent green fluorescence enhancement at 535 nm (273-fold). It afforded an LOD of 0.85 nM with signal saturation within 7 min across pH 3–11. Fabricated onto filter-paper, TLC plates and silica-gel substrates, this sensor enabled visual detection of both aqueous and gaseous N2H4, and accomplished practical N2H4 quantification in drinking water, river water, beverages, and human urine [131]. With sulfur atom incorporated, phenothiazine-derived dual-channel probe 103 was developed for differentiating of N2H4 and hypochlorous acid. N2H4 induced green turn-on emission at 520 nm, affording LOD of 23 nM and response time of 15 min. It enabled dual-color imaging of exogenous N2H4 and HClO in HeLa cells, zebrafish and Arabidopsis thaliana seedlings [132]. In 2026, quinolimide–thiophene-based probe 104 was prepared for colorimetric and fluorescent N2H4 detection. It generated obvious color change and green-yellow turn-on fluorescence at 542 nm, with an LOD of 75.21 nM and saturation within 50 min. Test strips paired with smartphone-assisted RGB analysis supported visual and quantitative N2H4 measurement. Furthermore, it enabled practical quantification in diverse water–soil environmental matrices, as well as fluorescence imaging in mung-bean sprouts and yeast cells [133].
Probe 105 was a colorimetric and fluorescent sensor constructed with a benzo[f]chromene fluorophore, which exhibits intrinsic ICT-based red fluorescence emission at 640 nm. Hydrazine-triggered nucleophilic attack disrupted the ICT system, resulting in significant color fading and fluorescence quenching. This chemodosimeter delivered an LOD of 25.97 μM with signal equilibrium within 40 min. Fabricated into electro-spun nanofibrous membranes, probe 105 enabled gaseous N2H4 sensing. Combined with a smartphone RGB recognition, it achieved on-site quantitative analysis of N2H4 in lake water. Moreover, it enabled visual detection of N2H4 residues in soil, food, and plant samples, as well as imaging in living MCF-7 cells [134].
Varying electron-withdrawing strengths of recognition moieties can distinctly alter the photophysical properties and sensing behaviors of D-π-A chemodosimeters (Figure 21). Three 1,8-naphthalimide-triphenylamine-based red-emitting probes, 106–108, were fabricated using 1,3-indandione, malononitrile, and 2-benzothiazoleacetonitrile as the electron-deficient acceptors. All probes displayed N2H4-induced fluorescence quenching originating from disruption of intrinsic ICT effect and activation of PET pathways. Of the series, probe 106 exhibited the optimal sensitivity with an LOD of 0.2 μM, whereas probes 107 and 108 delivered LODs of 0.4 μM and 54 μM, respectively. These probes could be made into test strips for naked-eye visualization of N2H4, and smartphone-assisted RGB analysis enabled quantitative N2H4 determination in practical water samples. Besides, they realized exogenous N2H4 imaging in A549 cells and nude mice [135]. Based on phenothiazine scaffold, three comparative probes, 109–111, were constructed by decorating 1,3-indandione, malononitrile and aldehyde groups. Benefiting from strongest electron-withdrawing capability of 1,3-indanedione, probe 109 exhibited superior sensing performance with green turn-on fluorescence at 515 nm, achieving signal equilibrium within 10 min and an LOD of 0.09 μM, which is superior to probe 110 (20 min, LOD 0.48 μM). In contrast, aldehyde-substituted probe 111 showed negligible response. Probe 109-immobilized test strips enabled visual N2H4 detection. Furthermore, it allowed N2H4 quantification in water and soil matrices, as well as fluorescence imaging in HeLa cells and living zebrafish [136].
Figure 21.
Chemical structures of probes 106–111.
2.3.2. (Thio)barbituric Acid as Recognition Groups
Barbituric acid, thiobarbituric acid, and their N-alkylated derivatives are a class of recognition moieties for N2H4 that have drawn significant attention in recent years, which affords ratiometric (112), turn-on (113–119), and turn-off (120–123) N2H4 fluorescent probes (Figure 22).
Figure 22.
Chemical structures of probes 112–123.
In 2025, a BODIPY-based ratiometric probe 112 was developed for N2H4. N2H4 treatment quenched the original red emission at 671 nm and induced newly emerged green fluorescence at 515 nm with a large 156 nm blue shift. The probe reached signal saturation within 10 min and afforded an LOD of 4.5 nM. Integrated onto test strips and combined with smartphone-assisted RGB analysis, it realized portable quantitative detection for both liquid and gaseous N2H4. It was also applied for N2H4 analysis in diverse practical matrices, including water, soil, crops, and food, as well as fluorescence imaging in HeLa cells, zebrafish, and Arabidopsis thaliana [137].
In 2023, a phenothiazine-based turn-on probe 113 utilized thiobarbituric acid as the recognition group for dual discrimination of N2H4 and hypochlorite. Both analytes cleaved the conjugated C=C bridge to afford hydrazone with blue fluorescence and aldehyde with green emission. This probe responded to N2H4 within 15 s with an LOD of 15.4 nM [138]. Adopting triphenylamine as the electron-donating unit, a series of turn-on fluorescent probes 114–118 exhibited favorable optical performance toward N2H4. For example, probe 114 achieved simultaneous discrimination of cyanide, hydrazine, and hypochlorite under identical excitation condition, producing distinguishable white (470 nm), green (503 nm), and orange (585 nm) fluorescence. It reached signal saturation within 4 min for all analytes, delivering LODs of 0.24 μM (CN-), 4.1 nM (N2H4) and 0.27 μM (ClO-) [139]. Dual-mode probe 115 differentiated N2H4 and hypochlorite via independent green (540 nm) and orange (623 nm) turn-on fluorescence. It afforded an LOD of 8 nM for hydrazine, with response time of 4 min [140]. Subsequently, probes 116–118 via varied recognition and electron-donating groups displayed N2H4-triggered blue turn-on fluorescence with distinct kinetic and sensitivity features. Probe 116 reached signal saturation in 10 s (LOD = 40 nM), while probes 117 and 118 both attained saturation within 5 s, with LODs of 20 nM and 12 nM, respectively [141,142,143]. In 2026, a naphthalene-based water-soluble probe 119 enabled selectively detecting N2H4 and hypochlorous acid. In the presence of N2H4, this probe generated blue fluorescence at 448 nm, delivering an LOD of 48 nM within 5 s [144]. Overall, probes 113–119 supported portable solid-phase sensing, complex real-sample chemical analysis, and multiscale biological fluorescence imaging.
In 2026, a turn-off fluorescent probe 120 discriminated glutathione (GSH) and N2H4 via distinct reaction pathways. GSH triggered rapid Michael-type thioether formation, while N2H4 underwent slow nucleophilic substitution to yield hydrazone adducts with signal saturation at 20 min and an LOD of 0.23 μM. Immobilized on paper strips, glass slides and natural-rubber-latex substrates, this probe enabled on-site visual screening of N2H4 in food-washing samples [145]. In the same year, three acridine-based fluorescent probes, 121–123, with varied barbiturate acceptors were fabricated for N2H4 sensing. Among them, probe 121 exhibited the optimal comprehensive performance, achieving obvious fluorescence quenching within 5 min and an LOD of 25 nM. Methylated (122) or sulfur-substituted (123) barbiturate analogues weakened both AIE effect and N2H4-responsive sensitivity. Benefiting from its favorable properties, probe 121 was integrated into agarose hydrogel to construct multifunctional sensors, which enabled smartphone-RGB-aided on-site quantification of gaseous and aqueous N2H4, and was suitable for N2H4 analysis in environmental-food samples. In addition, probe 121 allowed fluorescence bioimaging in HeLa cells and Arabidopsis thaliana [146].
2.3.3. Meldrum’s Acid as Recognition Groups
As a typical cyclic 1,3-dicarbonyl acceptor, Meldrum’s acid is also widely utilized to construct D-π-A fluorescent probes for N2H4 detection (Figure 23). Phenoxazine-based probe 124 displayed turn-on green fluorescence at 505 nm with an LOD of 4.2 nM and rapid response within 15 s. It was fabricated into filter-paper strips for gaseous and aqueous N2H4 visual detection and applied for real-sample analysis, as well as bioimaging in mung-bean sprouts and living zebrafish [147]. Phenothiazine-derived probe 125 exhibited turn-on green emission at 520 nm, with an LOD of 12 nM and signal saturation within 30 s. Coupled with smartphone-assisted RGB-R/G ratio analysis, it achieved quantitative N2H4 testing in water and sandy-soil samples. Its TLC test strips were exploited for gaseous N2H4 screening. Probe 125 also supported N2H4 visualization in food matrices and MCF-7 cell imaging [148]. Different from the above turn-on-type probes, xanthene-based NIR turn-off probe 126 produced obvious fluorescence quenching at 661 nm with a large Stokes shift of 231 nm. It achieved an LOD of 13.3 nM and reached equilibrium in 20 s, which was suitable for N2H4 quantitative measurement in water, soil, and rice samples and exogenous N2H4 imaging in HepG2 cells [149].
Figure 23.
Chemical structures of probes 124–126.
Comparative Assessment of Cyclic Dicarbonyl Recognition
Cyclic dicarbonyl acceptors provide the fastest hydrazine chemistry in this review. Barbiturates respond within seconds: probe 113 in 15 s (15.4 nM) [138], probes 116–119 in 5–10 s [141,142,143,144], and the Meldrum’s acid series 124–126 in 15–30 s (4.2–13.3 nM) [147,148], whereas 1,3-indandione probes typically need minutes (probe 98, 2 min [128]; probe 102, 7 min, 0.85 nM [131]; and probe 103, 15 min [132]). The ranking is not absolute: probe 120 required 20 min with a 0.23 μM LOD [145], and within the acridine series 121–123, methylated or sulfur-substituted barbiturates (probes 122 and 123) weakened both AIE and sensitivity relative to 121 (5 min, 25 nM). Fluorophore choice then sets the output: phenoxazine probe 124 (15 s, 4.2 nM) and BODIPY probe 112 (10 min, 4.5 nM) deliver sub-5-nM LODs with turn-on or ratiometric readouts [137,147], phenothiazine and triphenylamine scaffolds support N2H4/HClO or three-analyte discrimination (probes 103, 113, and 114–118) [132,138,139], and benzothiazole donor 98 combines ESIPT with ICT for pH (2.0–10.0) stable ratiometric output [128]. Matched acceptor series provide the strongest structure-performance evidence: 106–108 and 109–111 favor the indandione acceptor over malononitrile and benzothiazoleacetonitrile [135,136], and the 100/101 pair shows that a neighboring pyrimidine participates in recognition itself [130]. LODs span more than four orders of magnitude: barbiturates 112–119 and Meldrum’s acid 124–126 cluster at 4.1–48 nM together with indandione 102 (0.85 nM) and 103 (23 nM), whereas 99 (0.5 μM), 98 (1.29 μM), and 105 (25.97 μM) fall behind, so the fastest class is also the most sensitive by median LOD.
2.4. Other Electron-Deficient Double Bond (C=C or C=N)-Based Probes
Apart from cyano- and cyclic 1,3-diketone-based probes, other electron-deficient double bonds have emerged as viable recognition moieties for construction of N2H4-responsive fluorescent probes. These sensors follow a similar aza-Michael reaction principle, in which N2H4 nucleophilically attacks electron-poor C=C or C=N bonds to generate β-hydrazino adducts. These intermediates can further transform into hydrazones or cyclized products under appropriate conditions. The representative reaction pathways are illustrated below.
2.4.1. Formation of β-Hydrazino Adducts
In 2024, carbazole–hemicyanine probe 127 (Figure 24) recognized N2H4 via nucleophilic addition at the vinyl moiety, which disrupted the probe’s conjugated skeleton, triggering a ratiometric response with decreased emission at 605 nm and enhanced characteristic blue emission of carbazole at 450 nm. It afforded a fluorescence-based LOD of 0.16 μM and reached equilibrium within 25 min [150]. In 2026, dual-responsive ratiometric probe 128 reacted with N2H4 via a nucleophilic addition-cleavage pathway (Figure 24). This process weakened ICT effect, inducing a prominent red-to-blue fluorescence shift from 626 nm to 472 nm with an LOD of 24 nM. Benefiting from its molecular-rotor structure, probe 128 also exhibited viscosity-dependent emission enhancement at 626 nm through a TICT mechanism [151]. In the same year, ratiometric colorimetric–fluorogenic chemodosimeter 129 formed a N2H4 adduct (Figure 24), displaying diminished emission at 623 nm alongside newly-emerged cyan-blue fluorescence at 454 nm. The sensor afforded a fluorescence-based LOD of 0.72 μM, attained reaction completion within 5 min, and operated in pure aqueous media [152]. In 2025, benzothiazole–benzoindole-based probe 130 displayed N2H4-triggered turn-on fluorescence at 486 nm (Figure 24), with an LOD of 0.025 μM and signal stability in approximately 30 min [153]. These probes could be fabricated into portable solid-state platforms such as filter-paper strips and cotton swabs for naked-eye discrimination of both aqueous and gaseous N2H4. Smartphone-assisted RGB chroma-ratio analysis further allowed instrument-free on-site quantification. These sensing systems were validated in practical matrices, covering environmental water; soil extracts; and plant-derived samples such as bean sprouts, Arabidopsis roots, onion roots, and rice grains.
Figure 24.
Chemical structures of probes 127–130.
2.4.2. Formation of Hydrazone Products
Recently, a series of probes, 131–135, have been developed for N2H4 detection based on hydrazone formation reactions (Figure 25). In 2025, benzindolyl–hemicyanine–naphthyl probe 131 reacted with N2H4 to generate ratiometric fluorescence: emission at 600 nm declined while the signal at 450 nm increased. This D-π-A probe worked via an ICT-related mechanism with an LOD of 0.22 μM and signal saturation within 30 min. Fabricated into hydrogel test strips, swabs, and sensing gloves, it enabled visual detection of liquid and gas-phase N2H4, with smartphone-assisted B-R ratio quantification. It was applied in water, soil extracts, and plant-food samples for N2H4 sensing and food-freshness assessment [154]. In the same year, Golgi-targeting D-π-A probe 132 formed hydrazone upon reaction with N2H4, producing turn-on green-blue fluorescence at 508 nm. The reaction finished within 30 s affording an LOD of 0.816 μM. Besides test strip-based smartphone semi-quantitative detection for water–soil samples, this probe enabled fluorescence imaging of exogenous and isoniazid-derived endogenous N2H4 inside HepG2 cell Golgi apparatus and zebrafish [155].
Figure 25.
Chemical structures of probes 131–135.
Featuring benzothiazolium fluorophore scaffolds, three D-π-A turn-off fluorescent probes, 133–135, sensed N2H4 via an analogous nucleophilic addition–elimination pathway to form hydrazone. This transformation disrupted intrinsic ICT and induced prominent fluorescence quenching. Probe 133 reached signal equilibrium within 120 s with an LOD of 43 nM. It allowed instrumental quantification in tap and drinking water. The smartphone-aided R/G-ratio strategy further offered portable on-site quantitative capability [156]. Probe 134 attained signal saturation in 5 min with an LOD of 7.5 nM. Beyond environmental tests, it realized exogenous N2H4 fluorescence imaging in HepG2 cells, zebrafish, and onion tissues [157]. Probe 135 responded within 30 s with an LOD of 24.6 nM. It was fabricated into paper-based strips and cotton swabs for naked-eye discrimination of aqueous and gaseous N2H4, enabling quantitative analysis of water, soil, and rice samples. It also demonstrated exogenous N2H4 imaging in HepG2 cells, Arabidopsis roots, onion epidermis, and zebrafish [158].
Apart from C=C skeletons, C=N bond can also undergo similar transformations (Figure 26). In 2025, dipyrrolopyrazinedione-based aza-BODIPY dimer 136 realized dual-responsive detection of N2H4 and hypochlorite. Triggered by chromophore-fragmentation reaction, both analytes destroyed the conjugated fluorophore to generate distinct turn-on fluorescent outputs, affording LODs of 40 nM for N2H4 (30 min) and 59 nM for hypochlorite (10 min). Immobilized onto silica gel or PU sponge, it allowed naked-eye monitoring of liquid and gaseous N2H4. Smartphone-assisted RGB readout further enabled semi-quantitative evaluation of gaseous N2H4 [159]. In 2026, phenothiazine-based turn-on fluorescent probe 137 detected N2H4 via nucleophilic addition–elimination to form hydrazone. This process suppressed TICT and restored green fluorescence at 510 nm, with a response time of 40 s and an LOD of 35.3 nM. Paper-based test strips allowed naked-eye monitoring of aqueous and gaseous N2H4, and a smartphone-assisted platform adopting G/B chroma-ratio analysis realized quantification for water, soil and food samples. Probe 137 also accomplished exogenous N2H4 bioimaging in HepG2 cells, Arabidopsis roots, onion epidermis, E. coli, and zebrafish [160].
Figure 26.
Chemical structures of probes 136 and 137.
2.4.3. Formation of Cyclized Products
In 2024, mitochondria-targeted ratiometric fluorescent probe 138 responded to N2H4 through a unique intramolecular cyclization pathway, forming a spirocyclized product (Figure 27). This reaction induced ratiometric fluorescence changes with decreased emission at 590 nm and enhanced cyan emission at 488 nm. The probe reached signal equilibrium within 90 s with an LOD of 86.0 nM. Equipped with molecular-rotor character, it also sensed mitochondrial viscosity via TICT-to-PICT (planar intramolecular charge transfer) transformation. Cotton swab-based portable platforms enabled naked-eye discrimination of aqueous and gaseous N2H4, and quantitative detection was realized in water–soil matrices and mung bean-sprout plant samples. Probe 138 further accomplished ratiometric fluorescence imaging of exogenous N2H4 in HeLa cells [161].
Figure 27.
Chemical structures of probes 138.
Comparative Assessment of Other Electrophilic Double Bonds
Comparing the three reaction manifolds shows that the product pathway, not only the rate, defines the analytical output. β-hydrazino adduct formation (probes 127–130) preserves the fluorophore skeleton and gives moderate kinetics (probe 127, 25 min [150]; probe 129, 5 min [152]; and probe 130, 30 min [153]). Hydrazone-forming probes 132–135 are among the fastest probes in this review: probe 132, within 30 s [155]; probe 133, within 120 s (43 nM) [156]; and probe 135, in 30 s (24.6 nM) [158]. Cyclization-based probe 138 combines a 90 s response (86.0 nM) with spirocyclization-induced ratiometric readout and mitochondrial viscosity sensing [161], whereas the aza-BODIPY dimer 136 (30 min, 40 nM) achieves turn-on detection by destroying the NIR fluorophore itself [159].
2.5. Aldehyde-Based Probes
As another classic reactive site for N2H4-responsive fluorescent probes, aldehyde group undergoes nucleophilic addition–elimination pathway with N2H4 to yield hydrazone derivatives (Scheme 7) [162,163]. The newly formed C=N bonds modulate molecular conjugation and push–pull electronic features, thereby triggering ratiometric (139 and 140), turn-on (141, 142, and 144), or turn-off (145) fluorescence outputs (Figure 28).
Scheme 7.
Reaction process based on aldehyde probes.
Figure 28.
Chemical structures of probes 139–145.
In 2024, endoplasmic reticulum (ER)-targeted ratiometric probe 139 recognized N2H4 to give a ratiometric response with green emission quenched at 530 nm and a new blue band emerged at 460 nm. It reached signal plateau within ~12 min with an LOD of 2.5 nM. Interestingly, a symmetric bis-hydrazone was formed, which was unambiguously verified by single-crystal X-ray diffraction, NMR, and HRMS [164]. In 2026, ESIPT-active HBT-based probe 140 realized tandem-activatable detection of N2H4 and phosgene. N2H4-triggered condensation induced a distinct fluorescence blue shift from 574 nm to 495 nm, with an LOD of 5.1 nM in 5 min. The in situ generated hydrazone further reacted with phosgene to yield a cyclic adduct, achieving signal saturation in 10 s and an LOD of 0.49 μM [165]. Both probes 139 and 140 afforded paper-based sensing for visual liquid and gaseous N2H4 detection and were validated in practical water and soil samples. Probe 139 further enabled smartphone-aided on-site N2H4 quantification, as well as ER-targeted N2H4 bioimaging in HepG2 cells, zebrafish, and Arabidopsis thaliana. Probe 140 achieved sequential bioimaging of hydrazine and phosgene in living HeLa cells.
Benzothiadiazole-based 141 [166], triphenylamine-based 142 [167], and coumarin-based 144 [168] were representative turn-on fluorescent probes for N2H4. Upon nucleophilic addition–elimination with N2H4, they exhibited enhanced fluorescence at 375 nm, 520 nm, and 520 nm, respectively. These probes afforded variable sensing performances, reaching signal equilibrium within 10–20 min, with LODs of 0.34 μM, 0.24 μM, and 1.02 μM. Among them, probe 141 preferentially accumulated in lipid droplets and enabled N2H4 bioimaging in multiple biological models, including Chlorella sorokiniana, MDA-MB-231 cells, Caenorhabditis elegans, and zebrafish. Apart from N2H4, Probe 142 exhibited dual-response behavior for bisulfite and achieved lipid droplet-targeted bioimaging in HeLa cells. As a control molecule, carbazole-based probe 143 exhibited weak fluorescence enhancement toward N2H4 and failed to visually distinguish N2H4 and bisulfite. Featuring dual aldehyde reactive sites, Probe 144 could be fabricated into paper-based strips for naked-eye discrimination and allowed both visual detection of N2H4 in various soil matrices and bioimaging in HeLa cells [168].
In 2022, benzoindolium-based dual-response probe 145 employed aldehyde and vinyl groups for discriminative sensing of N2H4 and bisulfite. N2H4-triggered quenching of original orange fluorescence, achieving signal equilibrium within 80 s with an LOD of 7.8 nM. By contrast, bisulfite attacked both reactive sites to yield a ratiometric blue-shifted fluorescence output. This probe enabled differential bioimaging of bisulfite and N2H4 in living HeLa and HepG2 cells via separate fluorescence channels [169].
Comparative Assessment of Aldehyde Recognition
Aldehyde recognition offers milder chemistry and discrete, characterizable hydrazones. The fastest member is the benzoindolium dual-site probe 145 (80 s, 7.8 nM) [169], followed by the ER-targeted ratiometric probe 139 (~12 min, 2.5 nM) [164] and the HBT-based tandem probe 140 (5 min, 5.1 nM) [165], whereas turn-on probes 141–144 need 10–20 min (0.24–1.02 μM) [166,167,168]. The carbazole control 143, lacking the optimized push–pull architecture, gave only weak enhancement and failed to resolve N2H4 from bisulfite [167]. Sensitivity falls into two well-separated tiers: 145 (7.8 nM), 139 (2.5 nM) and 140 (5.1 nM) reach the nanomolar level, whereas the simple turn-on probes 142 (0.24 μM), 141 (0.34 μM), and 144 (1.02 μM) stay 30–400-fold higher.
2.6. Imide-Based Probes
The phthalimide moiety serves a reactive motif for N2H4-responsive chemodosimetric probes operating via Gabriel-type hydrazinolysis. When covalently tethered to fluorophores, the intact phthalimide unit normally quenches fluorescence of the parent probe through PET or ICT process. Nucleophilic N2H4 attacks the electrophilic carbonyl carbon, initiating sequential addition–elimination and ring-opening cleavage reactions (Scheme 8). This transformation releases phthalhydrazide and regenerates amino-functionalized fluorophores, thereby abolishing PET/ICT-induced fluorescence quenching and producing pronounced turn-on fluorescence signals [170,171,172].
Scheme 8.
Reaction process based on imide probes.
In 2022, carbazole-fluorene-based turn-on probe 146 was prepared with intrinsically weak background fluorescence originating from ICT quenching (Figure 29). N2H4-triggered phthalimide cleavage eliminated the ICT effect and generated local excited (LE)-state amino-substituted fluorophore, producing prominent fluorescence enhancement centered at 425 nm. This probe displayed obvious fluorescence increase within 10 min and attained full signal saturation at 100 min, affording an LOD of 2.5 μM. Integrated into TLC-based test strips, it enabled visual detection of gaseous N2H4. Furthermore, a custom portable optical detection platform loaded with 146 further lowered the LOD to 0.027 μM for real-world water samples [173]. In 2023, coumarin-based turn-on probe 147 exhibited weak initial fluorescence due to PET quenching (Figure 29). Upon reaction with N2H4, the PET restraint was removed and free amino-substituted coumarin fluorophore was liberated, yielding a prominent 28-fold fluorescence enhancement centered at 530 nm. The probe reached full signal saturation within 8 min, with a theoretical LOD of 91 nM in PBS buffer and a practical LOD of 0.148 μM in practical water samples. It accomplished multiscale bioimaging in HepG2 cells, zebrafish, and Arabidopsis thaliana root tissues. Furthermore, paper test strips and cotton swabs based on probe 147 supported visual detection of N2H4 in water, soil and vapor-phase samples [174]. In 2025, phenalenone-based dual-mode probe 148 was prepared for N2H4 detection, which exhibited prominent turn-on fluorescence at 600 nm (Figure 29). Requiring an incubation time of 45 min, probe 148 afforded an LOD of 490 nM, which was capable of N2H4 determination in practical water samples and fluorescence imaging of exogenous N2H4 inside A549 living cells [175].
Figure 29.
Chemical structures of probes 146–148.
In the same year, HBT-based sequential dual-emission ESIPT probe 149 was developed, which was initially non-emissive due to combined PET inhibition and blocked ESIPT processes. Through sequential Gabriel-type hydrazinolysis, it underwent two-step deprotection (Scheme 9). The first intermediate activated ESIPT to produce yellow emission at 575 nm (ON1 state), while further cleavage regenerated free amino-substituted fluorophore and switched to blue-emitting ON2 state at 468 nm. The yellow signal maximized at ~10 min while the blue emission plateaued at ~70 min, delivering an LOD of 18 nM. Benefiting from dual-color readout both in solution and solid state, probe 149 could be fabricated into test papers for N2H4-vapor visual sensing. It was applicable for multiscale N2H4 analysis, including environmental water–soil samples, food matrices, Arabidopsis thaliana, and rice root tissues, as well as HeLa-cell and zebrafish bioimaging. Additionally, smartphone-assisted quantitative analysis was realized for on-site practical detection [176].
Scheme 9.
Reaction process of probe 149 for detecting N2H4.
Comparative Assessment of Imide Recognition
Gabriel-type hydrazinolysis benefits from cyclic hydrazide formation and regeneration of an amino fluorophore, which can generate sequential emission states, but can require prolonged response time. Probe 147 reached saturation in 8 min [174], compared with 100 min for 146 [173]. For 149, the intermediate maximum at 10 min and the second emissive state at about 70 min describe different chemical states. Sensitivities span almost two orders of magnitude, from 18 nM (149) and 91 nM (0.148 μM in practical water, 147) [174] through 490 nM (148) [175] to 2.5 μM (0.027 μM with a portable device, 146) [173]. Such shifts show that LODs depend on the measurement conditions [173,174].
2.7. Chalcone-Based Probes
The α,β-unsaturated ketone unit of chalcone skeletons represents a well-established reactive site for designing N2H4-responsive fluorescent probes. Upon nucleophilic attack by N2H4, 1,4-Michael addition initiates a tandem addition-cyclization sequence, converting the chalcone moiety into a pyrazoline framework (Scheme 10). Such structural rearrangement disrupts the intrinsic ICT process and induces obvious photophysical alterations, enabling ratiometric (150–155), turn-on (156,157), or turn-off (158–164) N2H4 sensing (Figure 30 and Figure 31).
Scheme 10.
Reaction process based on chalcone probes.
Figure 30.
Chemical structures of probes 150–157.
Figure 31.
Chemical structures of probes 158–164.
In 2022, two coumarin-based ratiometric probes, 150 and 151, alongside control probe 152, were developed by regulating donor-acceptor architecture of the coumarin conjugated backbone. Compared with 150, probe 151 possessed a more electron-deficient coumarin unit, which activated the C=C double bond and facilitated N2H4-induced addition-cyclization to form pyrazoline-ring. Accordingly, probe 151 attained signal saturation within 70 min, considerably faster than 150 (200 min), whereas control probe 152 produced negligible spectral responses, confirming that electronic structure modulation could effectively accelerate such cascade reaction. Both probes produced large blue-shifted emissions of 229 nm (150) and 188 nm (151), which efficiently eliminated imaging crosstalk, with LODs of 0.14 μM and 0.26 μM, respectively [177]. In 2026, a bifunctional NIR probe 153 was developed, allowing simultaneous detection of N2H4 and environmental polarity. Upon reaction with N2H4, this probe exhibited ratiometric output with declined emission at 735 nm and enhanced emission at 490 nm together with a new band at 600 nm. It reached a steady state within ~20 min with an LOD of 1.60 μM [178]. In 2023, two HBT-derived probes, 154 and 155, afforded characteristic ratiometric blue-shifted fluorescence via disruption of the intrinsic π-conjugated skeleton and suppression of ICT-ESIPT processes. Probe 154 with longer π-conjugation emitted at 597 nm and reached equilibrium in 8 min. By contrast, probe 155 with a shorter π-bridge displayed emission at 577 nm and required 16 min for saturation, yielding LODs of 80.6 nM and 99.2 nM, respectively [179]. These probes (150–155) could be fabricated into test strips, TLC sheets and modified fabrics for naked-eye visual detection of gaseous N2H4. Smartphone-assisted RGB readout enabled semi-quantitative or quantitative analysis of N2H4 in tap-water, lake-water, soil, soil-leachate, sewage, and food matrices. They also supported ratiometric confocal bioimaging of exogenous N2H4 in HeLa cells. In addition, probe 153 could be incorporated into polymer matrices to prepare solid-state sensing films for environmental polarity monitoring.
In 2024, triphenylamine-based D-A-D’ probe 156 achieved dual recognition of N2H4 and Cu2+. N2H4 converted the probe from ratiometric to turn-on mode, accompanied by blue-shifted emission from 582 nm to 478 nm. The probe reached full response saturation within 190 min with an LOD of 33.9 nM. The generated dihydropyrazole could further recognize Cu2+ via 1:1 complexation and PET quenching mechanism. Probe 156 enabled accurate quantification of N2H4 and Cu2+ in real-world water samples [180]. In 2026, long-lived cyclometalated Ru(II)-coumarin hybrid probe 157 was prepared for N2H4 detection, which produced prominent turn-on luminescence at 630 nm and attained reaction equilibrium within 30 min. Benefiting from the long luminescence lifetime (> 300 ns), time-gated luminescence (TGL) measurement with a 20 ns delay was implemented to suppress short-lived autofluorescence interference, achieving background-free N2H4 detection with an LOD of 1.4 nM. This Ru-complex TGL probe was further applied for N2H4 quantitation in drug, food matrices, and water samples, as well as semi-quantitative luminescence bioimaging in living 4T1 cells [181].
Apart from the above probes, a series of ICT-based fluorescent probes 158–164 were also developed (Figure 31), which exhibited turn-off fluorescence and visible yellow-to-colorless changes toward N2H4. In 2025, benzothiophene-based semi-bis-chalcone probes 158 and 159 were reported, among which probe 159 exhibited superior photophysical performance with a fast 2 min response [182]. Structural modulation yielded probe 160 (LOD 0.89 μM, equilibrium within 2 min) [183] and furan-substituted probe 161 (LOD 0.77 μM, equilibrium within 5 min) [184]. Besides semi-bis-enone scaffolds, biphenyl–benzothiophene-based probe 162 achieved a 3 min response with an LOD of 0.11 μM [185]. Pyrene-based probes 163 [186] and 164 [187] delivered ultra-large 364 nm and 257 nm Stokes shifts, with LODs of 0.12 μM and 0.33 μM, respectively. Collectively, these probes exhibited good practicability for real-sample analysis. Most realized N2H4 quantitation in environmental water and various soil matrices, and could be fabricated into paper test strips for instrument-free visual detection of gaseous N2H4. Several probes were further expanded to food-related matrices, including rice and mung-bean sprouts, demonstrating promising potential for food safety monitoring.
Comparative Assessment of Chalcone Recognition
Within this family the cascade rate follows the acceptor electronics: the more electron-deficient 151 saturated in 70 min against 200 min for 150 (LODs 0.26 and 0.14 μM), with control 152 unresponsive [177], whereas the triphenylamine-based D-A-D′ probe 156 needed 190 min despite its dual N2H4/Cu2+ response [180]. LODs span three orders of magnitude, from 1.4 nM (157) and 33.9 nM (156) through 80.6 nM (154) and 99.2 nM (155) to 0.11–0.26 μM (162, 163, 150, and 151), 0.33–0.89 μM (164, 161, and 160), and 1.60 μM (153), with 159 weakest at 5 μM
2.8. Dual Recognition Sites-Based Probes
Apart from single reactive-site chemodosimeters, dual recognition sites-based probes integrate two distinct responsive functional groups into one fluorophore skeleton, which can respond toward one target analyte via cascade reactions or discriminate multiple analytes with differentiated optical outputs [188,189,190]. The representative reaction processes are illustrated below.
Benefiting from the intrinsic ESIPT photophysical property of the HBT fluorophore, probes 165–169 can produce dual-channel fluorescence signals. With rationally designed dual-reactive recognition sites and tunable ICT modulation, these sensors realize discriminative multi-analyte detection with diversified fluorescence responses for hydrazine and other analytes (Scheme 11). In 2022, ratiometric HBT-benzothiazolium probe 165 realized specific N2H4 sensing. N2H4 underwent sequential nucleophilic addition at the electrophilic benzothiazolium C=N+ site and condensation with aldehyde group. This disrupted the original ICT and generated a new emissive species, producing ratiometric response with quenched NIR emission at 652 nm and intensified blue fluorescence at 438 nm. The probe reached signal saturation within 2 min, affording an LOD of 50.8 nM [191]. Both reported in 2024, Probe 166 [192] and 167 [193] were designed for the simultaneous discrimination of H2S and N2H4. For probe 166, H2S cleaved the 2,4-dinitrophenyl (DNP) group via nucleophilic substitution to yield 166-OH, triggering ESIPT-activated NIR turn-on fluorescence at 713 nm. N2H4-triggered a two-step transformation through the 166-OH intermediate to form 166-NH2 with cyan emission at 508 nm, affording an LOD of 0.490 μM over 60 min [192]. For mitochondria-targeted probe 167, H2S-mediated deprotection of thienoyl ester to regenerate fluorophore 167-OH, giving dual emission enhancement at 485 nm and 590 nm, while N2H4 induced sequential thienoyl deprotection and C=C bond cleavage, producing single turn-on emission at 510 nm. It afforded an LOD of 23.6 nM for N2H4, with response within 10 s [193]. In 2026, dual-response probe 168 realized orthogonal discrimination of thiophenol and N2H4. Thiophenol cleaved the 2,4-dinitrobenzenesulfonyl (DNBS) quenching group to block d-PET and restored ICT-ESIPT processes, producing prominent orange-red emission at 635 nm. N2H4 induced hydrazinolysis of both DNBS and indandione moieties, altering molecular electronic distribution and generating green fluorescence at 490 nm. It reached signal saturation within 5 min for N2H4, delivering an LOD of 1.016 μM [194]. In the same year, benzothiazole–chalcone-based probe 169 achieved discriminative sensing of Hg2+ and N2H4. Hg2+-induced desulfurization cleaved phenyl carbonothioate (PCS) quenching moiety to recover orange turn-on fluorescence at 610 nm. For hydrazine, probe 169 underwent sequential PCS-group removal followed by pyrazoline formation, affording cyan turn-on emission at 478 nm. The probe 169 delivered an LOD of 1.19 μM for hydrazine, reaching signal saturation within 3 min [195]. Collectively, these HBT-based probes 165–169 exhibited promising practical potential. They were suitable for on-site visual and quantitative detection of analytes in environmental and food matrices. With low cytotoxicity, these probes support confocal bioimaging in diverse living biological models.
Scheme 11.
Reaction process of probe 165–169 for detecting N2H4.
In 2022, ratiometric fluorescent probes 170–172 with varied fluorophore backbones have been developed for specific N2H4 detection (Scheme 12). For mitochondria-targeted coumarin-pyridinium probe 170, N2H4 induced sequential acetyl elimination and hydrazone formation to produce dual-ratiometric fluorescence signals. Upon 420 nm excitation, the initial 470 nm emission diminished; under 600 nm excitation, the intrinsic 650 nm NIR emission decayed, with a new green signal emerging at 520 nm in both cases. The probe reached signal equilibrium within 15 min, delivering LODs of 68 nM (λex = 420 nm) and 569 nM (λex = 600 nm), respectively. Notably, transient intermediate was confirmed via time-dependent ESI-MS and 1H NMR titration [196]. For pyrene-chalcone probe 171 with an acryloyl ester group, N2H4 induced ester cleavage and subsequent pyrazoline formation, switching the fluorescence from yellow emission at 576 nm to blue-violet emission centered at 393 nm with up to 800-fold enhancement. It achieved signal saturation in 15 min with an LOD of 1.9 nM [197]. For phenothiazine-based bifunctional probe 172, at low N2H4 concentrations, only the benzothiazole-acetonitrile moiety reacted, while higher N2H4 loading induced sequential reactions at both sites. This triggered reduced emission at 675 nm and increased fluorescence at 545 nm. The probe achieved initial fast response within 1 min and reached full equilibrium in ca. 25 min, with an LOD of 0.08 μM. Collectively, these probes enabled ratiometric bioimaging of exogenous N2H4 in living cells and zebrafish. They could be fabricated into test strips for visual gaseous N2H4 detection and allowed N2H4 quantitation in environmental water and soil samples [198].
Scheme 12.
Reaction process of probe 170–172 for detecting N2H4.
In 2025, unsymmetrical NIR BF2-complex 173 was constructed for N2H4 detection (Scheme 13). Analogues 174 and 175 were prepared as reference compounds, which shared identical main skeleton but differed in the side-chain heteroaryl-acetonitrile moieties. Probe 173 possessed favorable solubility and optimal reactivity toward hydrazine. Triggered by synergistic acrylonitrile elimination, multiple B-N bond cleavage and C=N hydrolysis, hydrazine disrupted the π-conjugated skeleton and produced ratiometric colorimetric-fluorescent responses, with declined NIR emission at 702 nm and increased new fluorescence at 510 nm. It delivered an LOD of 4.53 nM, with signal reaching saturation within 5 min. Fabricated into filter-paper, sponge, and silica-gel substrates, as well as coupled with smartphone-assisted RGB analysis, it achieved visual and quantitative detection of both gaseous and aqueous N2H4, and was further applied for N2H4 quantitation in water and soil samples [199]. In 2024, mitochondria-targeted dual-responsive probe 176 was designed to discriminate H2S and N2H4 (Scheme 13). The DNP group responded to H2S to produce NIR turn-on emission at 680 nm, while N2H4 attacked both DNP ether and C=C vinyl bridge, triggering green turn-on fluorescence at 488 nm without spectral crosstalk. This probe afforded an LOD of 40 nM for hydrazine with fast response within 30 s. Probe 176 realized dual-channel bioimaging of Cys- and isoniazid-metabolized endogenous H2S and N2H4 in HeLa cells and mice, and it was further applied for analysis in practical soil and food samples [200].
Scheme 13.
Reaction process of probe 173–176 for detecting N2H4.
Comparative Assessment of Dual Recognition Sites
Two responsive sites can provide distinguishable pathways or sequential products, but they do not automatically create a hydrazine-specific AND gate. Several systems deliberately respond to H2S, thiophenol, Hg2+ or other analytes [192,193,194,195,200]. Cascade designs (165, 170, and 171) convert two sequential reactions into ratiometric outputs with 2–15 min endpoints [191,196,197]. Sensitivity spans nearly three orders of magnitude, from 171 (1.9 nM), 173 (4.53 nM), and 167 (23.6 nM) through 176 (40 nM) and 165 (50.8 nM) to 172 (0.08 μM), 168 (1.016 μM), 166 (0.49 μM), and 169 (1.19 μM).
3. Other Organic Probe Systems for N2H4
Beyond the aforementioned small-molecule fluorescent probes, other organic probe systems involving novel mechanisms have also been exploited for N2H4 sensing (Figure 32). In 2024, an artificial light-harvesting supramolecular system based on AIE-active platinum(II) metallacycle (TPEMc) and rhodol derivatives (P1–P3) was reported for ratiometric N2H4 detection [201]. Positively charged TPEMc nanoaggregates served as the energy donor, while ester-caged rhodol derivatives (P1–P3) acted as responsive acceptors. Upon N2H4-triggered ester cleavage, fluorescent open-form rhodol RL was released, activating FRET and generating ratiometric fluorescence responses, making it superior to free rhodol probes.
Figure 32.
Other organic probe systems for N2H4.
Besides supramolecular systems, polymer-modified fluorescent probes have also been exploited for N2H4 detection. In 2025, a biomass-derived macromolecular fluorescent material FNA-B-CA was reported, where AIE-active naphthalimide fluorophore was covalently grafted onto cellulose-acetate polymer chains. The aldehyde recognition site on FNA-B-CA specifically reacted with N2H4 to form hydrazone, inducing fluorescence quenching at 432 nm. This polymer probe afforded an LOD of 84 nM [202]. In the same year, dicyanovinyl-modified poly(PCDA-dcv) vesicles were constructed via photopolymerization of self-assembled amphiphilic monomers. Upon exposure to N2H4, the dicyanovinyl side-chain group underwent addition–elimination reaction to form hydrazone, inducing backbone conformational distortion and a characteristic blue-to-purple color transition of the vesicle, with an LOD of 5.3 μM [203].
To solve poor aqueous solubility, in 2023, a chalcone-based small-molecule T1 bearing dual recognition sites was encapsulated within the hydrophobic domain of amphiphilic mPEG-DSPE copolymer to obtain water-dispersed micellar nano-T1 with ~190 nm hydrodynamic diameter. N2H4-triggered a typical turn-off fluorescence response with quenched NIR emission at 610 nm, affording an LOD of 0.692 μM [204]. In 2024, aldehyde-functionalized AIEgen T2 was assembled with Fe3O4 magnetic nanoparticles to fabricate tumbleweed-like magnetic AIE-bots. Upon reacting with N2H4, aldehyde groups on the porous micro-robot formed Schiff-base adducts, which restricted intramolecular rotation-vibration and produced prominent turn-on fluorescence at 489 nm, affording an LOD of 3.81 ppb [205].
Beyond fluorescence-based sensing strategies, photoelectrochemical (PEC) platforms provide an alternative avenue for N2H4 analysis. In 2024, a D-π-A structured organic photoactive dye T3 bearing acetyl recognition sites was covalently anchored onto an FTO/TiO2 substrate to construct a PEC photoanode. N2H4 induced cleavage of acetyl group to generate phenoxide anions with strong electron-donating character, which strengthens ICT effect and greatly boosts visible-light-driven photocurrent signal, affording an LOD of 21.8 nM [206].
4. Conclusions
Benefiting from the strong nucleophilicity of hydrazine (N2H4), a large family of reaction-based fluorescent probes has been developed, with hydroxyl deprotection, hydrazone formation, chalcone cyclization, Gabriel-type phthalimide reaction, and hydrogen-bond-mediated sensing as the representative recognition mechanisms, and coumarin, rhodamine, hemicyanine, phenothiazine, benzothiazole, and naphthalimide as the dominant fluorophores. The main advances, remaining challenges, and future directions are summarized below.
4.1. Main Advances
Sensitivity has reached the regulatory-relevant range. Among the 141 representative probes in Table S1, 70 operate in a turn-on mode, 45 in a ratiometric mode, and 26 in a turn-off mode, and the majority report LODs below the USEPA threshold (10 ppb, 0.31 μM), with many in the low-nanomolar range. For example, probe 52 (0.41 nM [87]), probe 68 (0.46 nM [103]), and probe 102 (0.85 nM [131]) reach the low-nanomolar range. Across recognition groups, cyclic 1,3-diketones and cyano-based probes afford the lowest median LODs, with sub-nanomolar records held by a malononitrile probe 52 and a 1,3-indandione probe 102. By contrast, imide- and chalcone-based probes are generally less sensitive.
Response times have been shortened to seconds for the most recognition groups. Kinetics are governed mainly by the electrophilicity and steric accessibility of the reactive site, and strongly activated C=C electrophiles respond within seconds. For example, probe 68 (malononitrile, 1 s [103]), probes 53/71 (≤5 s [88,104]), cyclic 1,3-diketones (probes 117–119, 5 s [142,143,144]), Meldrum’s-acid probes (124–126, 15–30 s [147,148,149]), and ester (probe 29, 15 s [61]). Such sub-minute responses are not confined to one recognition group: they account for ~41% of cyclic 1,3-diketones, ~20–27% of cyano, electron-deficient-alkene and dual-site probes, and 14% of esters, whereas none of the aldehyde, imide, or chalcone probes responds within 1 min. Taking the group as a whole, cyclic 1,3-diketones show the shortest median response. The longest individual responses (100–200 min) are isolated outliers in the chalcone (probes 151 and 156 [177,180]) and cyano (probe 81 [113]) families.
Water compatibility has improved. A subset of probes now operates in purely aqueous media, with representative examples including probe 124 (LOD 4.2 nM, 15 s [147]), probe 119 (48 nM, 5 s [144]), probe 112 (4.5 nM, 10 min [137]), and probe 63 (28.5 nM, 35 s [98]), showing that cosolvent-free operation need not sacrifice sensitivity. Hydrophilic decoration (e.g., the sulfonic acid of probe 12 [45] and PEG chains of probe 16 [49]) is the common design strategy.
NIR emission has expanded the imaging depth. NIR donor–acceptor systems account for 31 of the 141 probes (22%), led by charge-separated skeletons such as dicyanoisophorone (probes 8–11 [40,41]), hemicyanine (probes 12,13,15,16 [45,46,47,48,49]), BODIPY/aza-BODIPY (probes 96,112 [126,137]), and naphthalimide (probe 106 [135]), with the longest emission reaching 825 nm (probe 96 [126]). Their deep-tissue penetration, low autofluorescence, and low photodamage [42,43,44] underpin this preference, although all current probes remain in the NIR-I window (no emission beyond 900 nm).
Portable test strips, filter papers, smartphone-assisted RGB, and hydrogel-based labels now enable visual, instrument-free detection, and practical quantitation has been demonstrated in water, soil, and food samples.
4.2. Remaining Challenges
In complex biological environments, endogenous nucleophiles (glutathione, cysteine, H2S, bisulfite, and primary amines), which are present at high intracellular levels, can consume N2H4 or compete for the same electrophilic site. However, most selectivity panels are recorded at only 10–100 μM, concentrations far below their intracellular abundance. Systematic cross-reactivity testing at physiologically relevant ratios still remains underreported. More fundamentally, essentially all “endogenous N2H4” imaging reported in this review relies on hydrazine generated from exogenously administered isoniazid, a pharmacological rather than physiological source, and should therefore be read as drug-metabolism sensing.
Analytical robustness in real-world matrices remains unevenly documented. Spike-recovery assays in water, soil extracts, and food are now routine, and several probes extend to urine, serum, and other bio-fluids, but spikes are usually applied well above the 0.31 μM USEPA threshold, so accuracy near the regulatory decision level is untested. Matrix effects are seldom quantified using matrix-matched calibration, and results are rarely corroborated by an orthogonal reference method (GC–MS or HPLC–MS/MS). Hydrophilicity is a further practical bottleneck: 116 of the 141 probes (82%) require organic cosolvent, and biocompatibility is usually limited to a single-cell-line viability assay, with hemolysis, long-term, and metabolite toxicity seldom examined.
4.3. Future Perspectives
Improving water solubility, red-shifting emission, accelerating the analytical response, and constructing ratiometric outputs are general objectives shared by the wider fluorescent-sensor community. The distinctive opportunities of this field lie instead in the chemodosimetric recognition event: expanding hydrazine-unique reactions (e.g., Gabriel-type cyclization and pyrazoline formation) with quantified rate constants, standardizing interference and biocompatibility evaluation protocols, and coupling fluorescence sensing with hydrazine adsorption or degradation in multifunctional platforms. Advances along these lines are expected to translate hydrazine probes from proof-of-concept sensors into routine tools for environmental monitoring and biosafety assessment.
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/molecules31234324/s1, Table S1. The different mechanisms and parameters of representative probes.
Author Contributions
H.Z., visualization, data curation, and writing—original draft; Z.Z., visualization and data curation; Y.M., visualization and data curation; M.X., writing—original draft; M.R., writing—original draft; Y.P., data curation; H.L., data curation; S.L., writing—review and editing; T.Z., writing—review and editing; X.Z., conceptualization, visualization, data curation, and writing—review and editing; X.-Q.H., conceptualization, writing—review and editing. All authors have read and agreed to the published version of the manuscript.
Funding
Financial support from the National Natural Science Foundation of China (Nos. 21803059, 22401267, and 22671324) and the Natural Science Foundation of Henan Province (252300421282) is gratefully appreciated.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
No new data were created or analyzed in this study. Data sharing is not applicable to this article.
Conflicts of Interest
Heping Li is an employee of Henan Easy Joint New Materials Research Institute Co., Ltd. The other authors declare no conflicts of interest. Henan Easy Joint New Materials Research Institute Co., Ltd. had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
References
- Furst, A.; Berlo, R.C.; Hooton, S. Hydrazine as a reducing agent for organic compounds (catalytic hydrazine reductions). Chem. Rev. 1965, 65, 51–68. [Google Scholar] [CrossRef] [Scilit]
- Costoyas, Á.; Ramos, J.; Forcada, J. Hydrazine-functionalized latexes. J. Polym. Sci. Part A Polym. Chem. 2009, 47, 6201–6213. [Google Scholar] [CrossRef] [Scilit]
- Serov, A.; Kwak, C. Direct hydrazine fuel cells: A review. Appl. Catal. B Environ. 2010, 98, 1–9. [Google Scholar] [CrossRef] [Scilit]
- Lan, R.; Irvine, J.T.S.; Tao, S. Ammonia and related chemicals as potential indirect hydrogen storage materials. Int. J. Hydrogen Energy 2012, 37, 1482–1494. [Google Scholar] [CrossRef] [Scilit]
- Garrod, S.; Bollard, M.E.; Nicholls, A.W.; Connor, S.C.; Connelly, J.; Nicholson, J.K.; Holmes, E. Integrated metabonomic analysis of the Multiorgan effects of hydrazine toxicity in the rat. Chem. Res. Toxicol. 2005, 18, 115–122. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Binyamin, Y.; Frenkel, A.; Brotfain, E.; Koyfman, L.; Shliom, O.; Klein, M. Elevated CPK levels after hydrazine inhalation exposure in an F16 aircraft technician. Toxicol. Rep. 2018, 5, 927–928. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Choudhary, G.; Hansen, H. Human health perspective of environmental exposure to hydrazines: A review. Chemosphere 1998, 37, 801–843. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Reilly, C.A.; Aust, S.D. Peroxidase substrates stimulate the oxidation of hydralazine to metabolites which cause single-strand breaks in DNA. Chem. Res. Toxicol. 1997, 10, 328–334. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, X.; Li, C.; Li, C.; Wu, C.; Bai, Y.; Zhao, X.; Bai, Z.; Zhang, X.; Xiao, X.; Niu, M. A novel perspective on the preventive treatment of hydrazine compound-induced liver injury: Isoniazid liver injury as an example. J. Ethnopharmacol. 2023, 315, 116616–116627. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Vernot, E.; MacEwen, J.; Bruner, R.; Haun, C.; Kinkead, E.; Prentice, D.; Hall, A., III; Schmidt, R.; Eason, R.; Hubbard, G. Long-term inhalation toxicity of hydrazine. Fund. Appl. Toxicol. 1985, 5, 1050–1064. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hainer, M.I.; Tsai, N.; Komura, S.T.; Chiu, C.L. Fatal hepatorenal failure associated with hydrazine sulfate. Ann. Intern. Med. 2000, 133, 877–880. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- U.S. Environmental Protection Agency. Hydrazin-Acute Exposure Guideline Levels; U.S. Environmental Protection Agency: Washington, DC, USA, 2010; pp. 274–326.
- Wang, S.; Ma, S.; Zhang, J.; She, M.; Liu, P.; Zhang, S.; Li, J. A highly sensitive and selective near-infrared fluorescent probe for imaging hydrazine in living tissues and mice. Sens. Actuators B Chem. 2018, 261, 418–424. [Google Scholar] [CrossRef] [Scilit]
- Sun, M.; Bai, L.; Liu, D.Q. A generic approach for the determination of trace hydrazine in drug substances using in situ derivatization-headspace GC-MS. J. Pharm. Biomed. Anal. 2009, 49, 529–533. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Smolenkov, A.D.; Shpigun, O.A. Direct liquid chromatographic determination of hydrazines: A review. Talanta 2012, 102, 93–100. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- George, M.; Nagaraja, K.S.; Balasubramanian, N. Spectrophotometric determination of hydrazine. Talanta 2008, 75, 27–31. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mohammad, A.; Khan, M.E.; Alarifi, I.M.; Cho, M.H.; Yoon, T. A sensitive electrochemical detection of hydrazine based on SnO2/CeO2 nanostructured oxide. Microchem. J. 2021, 171, 106784. [Google Scholar] [CrossRef] [Scilit]
- Antherjanam, S.; Saraswathyamma, B. Simultaneous electrochemical determination of hydrazine and hydroxylamine on a thiadiazole derivative modified pencil graphite electrode. Mater. Chem. Phys. 2022, 275, 125223. [Google Scholar] [CrossRef] [Scilit]
- Crapnell, R.D.; Banks, C.E. Electroanalytical overview: The electroanalytical sensing of hydrazine. Sens. Diagn. 2022, 1, 71–86. [Google Scholar] [CrossRef] [Scilit]
- Gu, X.; Camden, J.P. Surface-Enhanced Raman Spectroscopy-Based Approach for Ultrasensitive and Selective Detection of Hydrazine. Anal. Chem. 2015, 87, 6460–6464. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dong, F.; Zhu, J.; Ye, Z.; Cao, G.; Xiang, D.-J.; Wang, W.-L. Recent Progress in Fluorescent Probes for Hydrazine Detection with Double-Bond Structural Features. Crit. Rev. Anal. Chem. 2026, 1–22. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, L.; Cheng, L. Advances in Optical Probes for the Detection of Hydrazine in Environmental and Biological Systems. Crit. Rev. Anal. Chem. 2025, 55, 53–82. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Qin, X.; Lin, M.; Lai, Z.; Mo, J.; Wen, S.; Yang, X. The fluorescent and bioluminescent probes for detecting hydrazine in recent years. Dye. Pigment. 2024, 231, 112378. [Google Scholar] [CrossRef] [Scilit]
- Gao, L.-L.; Pang, S.; Gao, Y.; Shi, D.; Guo, Y. Recent development of organic small-molecule and nanomaterial fluorescent probes for hydrazine. Adv. Agrochem. 2022, 1, 22–38. [Google Scholar] [CrossRef] [Scilit]
- Wang, E.; Ma, H.; Lu, J.; Wang, F.; Ren, J. Recent progress in the fluorescent probes for hydrazine detection. Tetrahedron 2022, 124, 132989. [Google Scholar] [CrossRef] [Scilit]
- Zhang, X.-Y.; Yang, Y.-S.; Wang, W.; Jiao, Q.-C.; Zhu, H.-L. Fluorescent sensors for the detection of hydrazine in environmental and biological systems: Recent advances and future prospects. Coord. Chem. Rev. 2020, 417, 213367. [Google Scholar] [CrossRef] [Scilit]
- Yan, L.; Zhang, S.; Xie, Y.; Mu, X.; Zhu, J. Recent progress in the development of fluorescent probes for the detection of hydrazine (N2H4). Crit. Rev. Anal. Chem. 2020, 24, 210–229. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Manna, S.K.; Gangopadhyay, A.; Maiti, K.; Mondal, S.; Mahapatra, A.K. Recent developments in fluorometric and colorimetric chemodosimeters targeted towards hydrazine sensing: Present success and future possibilities. ChemistrySelect 2019, 4, 7219–7245. [Google Scholar] [CrossRef] [Scilit]
- Roy, B.; Bandyopadhyay, S. The design strategies and mechanisms of fluorogenic and chromogenic probes for the detection of hydrazine. Anal. Methods 2018, 10, 1117–1139. [Google Scholar] [CrossRef] [Scilit]
- Nguyen, K.H.; Hao, Y.; Chen, W.; Zhang, Y.; Xu, M.; Yang, M.; Liu, Y.-N. Recent progress in the development of fluorescent probes for hydrazine. Luminescence 2018, 33, 816–836. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tong, C.; Fan, L.; Cai, G.; Shi, S.; Yang, Y.; Guo, Y. Design of a sustainable light-up flavonol probe for dual-ratiometric fluorescent sensing and visual differentiating ammonia and hydrazine. Food Chem. 2023, 421, 136216. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, Y.; Yan, Q.; Wang, Z.; Xu, H. A flavonol-derived fluorescent probe for highly specific and sensitive detection of hydrazine in actual environmental samples and living zebrafish. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2023, 288, 122132. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tse, H.; Li, Q.; Chan, S.; You, Q.; Lee, A.W.M.; Chan, W. A ratiometric fluorescent and colorimetric probe for selective detection of hydrazine. RSC Adv. 2016, 6, 14678–14681. [Google Scholar] [CrossRef] [Scilit]
- Qu, P.; Ma, X.; Chen, W.; Zhu, D.; Bai, H.; Wei, X.; Chen, S.; Xu, M. A coumarin-based fluorescent probe for ratiometric detection of hydrazine and its application in living cells. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2019, 210, 381–386. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shi, X.; Yin, C.; Wen, Y.; Zhang, Y.; Huo, F. A probe with double acetoxyl moieties for hydrazine and its application in living cells. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2018, 203, 106–111. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tian, X.; Li, M.; Zhang, Y.; Gong, S.; Wang, X.; Wang, Z.; Wang, S. A coumarin-based fluorescent probe for hydrazine detection and its applications in real water samples and living cells. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2023, 437, 114467. [Google Scholar] [CrossRef] [Scilit]
- Guo, S.-H.; Leng, T.-H.; Wang, K.; Shen, Y.-J.; Wang, C.-Y. A near-infrared xanthene-based fluorescent probe for selective detection of hydrazine and its application in living cells. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2019, 223, 117344. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Vijay, N.; Velmathi, S. Near-Infrared-Emitting Probes for Detection of Nanomolar Hydrazine in a Complete Aqueous Medium with Real-Time Application in Bioimaging and Vapor-Phase Hydrazine Detection. ACS Sustain. Chem. Eng. 2020, 8, 4457–4463. [Google Scholar] [CrossRef] [Scilit]
- Tang, S.; Wu, H.; Han, Y. A FRET-based ratiometric fluorescent probe for selective hydrazine detection, live imaging, and portable sensing. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2026, 351, 127479. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Luo, L.; Cheng, J.; Chen, S.; Zhang, P.; Chen, S.; Tang, Z.; Zeng, R.; Xu, M.; Hao, Y. A near-infrared ratiometric fluorescent probe for hydrazine and its application for gaseous sensing and cell imaging. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2023, 296, 122692. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xia, H.-C.; Zhang, Y.-H.; Lv, L.-M.; Han, D.; Yang, H.-K.; Yan, H.-J.; Lv, J.-L.; Lin, J.-T.; Kong, Y.-Y. Dicyanoisophorone-based near-infrared fluorescent probe with a large Stokes shift for the detection and bioimaging of hydrazine. J. Hazard. Mater. 2026, 502, 141061. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, T.; Liu, J.; Song, L.; Li, Z.; Qi, Q.; Huang, W. A hemicyanine-based fluorescent probe for hydrazine detection in aqueous solution and its application in real time bioimaging of hydrazine as a metabolite in mice. J. Mater. Chem. B. 2019, 7, 3197–3200. [Google Scholar] [CrossRef] [Scilit]
- Song, Y.; Chen, G.; Han, X.; You, J.; Yu, F. A highly sensitive near-infrared ratiometric fluorescent probe for imaging of mitochondrial hydrazine in cells and in mice models. Sens. Actuators B Chem. 2019, 286, 69–76. [Google Scholar] [CrossRef] [Scilit]
- Guo, X.; Li, S.; Mu, S.; Zhang, Y.; Liu, X.; Zhang, H. A merocyanine-based dual-mode optical probe for detection of hydrazine and its bioimaging application in vitro and vivo. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2020, 226, 117625. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, Y.; Xue, X.-L.; Wang, K.-P.; Chen, S.; Tang, L.; Hu, Z.-Q. A hemicyanine-based near-infrared fluorescent probe for vapor-phase hydrazine detection and bioimaging in a complete aqueous media. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2022, 279, 121406. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, Z.; Liu, Q.; Cai, S.; Liu, C.; He, S.; Zhao, L.; Zeng, X.; Gong, J. A near-infrared and large Stokes shift xanthene-indolium sensor for probing hydrazine in mitochondria. Dye. Pigment. 2022, 203, 110382. [Google Scholar] [CrossRef] [Scilit]
- Wang, Z.; Zhang, Y.; Meng, Z.; Li, M.; Zhang, C.; Yang, L.; Yang, Y.; Xu, X.; Wang, S. Development of a ratiometric fluorescent probe with large Stokes shift and emission wavelength shift for real-time tracking of hydrazine and its multiple applications in environmental analysis and biological imaging. J. Hazard. Mater. 2022, 422, 126891. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cao, B.; Li, H.; Wu, Z.; Yin, J.; Wang, W.; Li, C. A near-infrared fluorescent off-on probe with large Stokes shift for sensing hydrazine in vitro and in vivo. Tetrahedron 2023, 147, 133665. [Google Scholar] [CrossRef] [Scilit]
- Chu, Q.; Nie, Z.; Bian, Y.; Tian, J.; Li, J.; Xu, L.; Xu, H. A visual and quantitative turn-on near-infrared fluorescent probe for detecting N2H4 and its application in bioimaging. J. Mol. Struct. 2026, 1351, 144268. [Google Scholar] [CrossRef] [Scilit]
- Xia, X.; Zeng, F.; Zhang, P.; Lyu, J.; Huang, Y.; Wu, S. An ICT-based ratiometric fluorescent probe for hydrazine detection and its application in living cells and in vivo. Sens. Actuators B Chem. 2016, 227, 411–418. [Google Scholar] [CrossRef] [Scilit]
- Hao, Y.; Zhang, Y.; Ruan, K.; Chen, W.; Zhou, B.; Tan, X.; Wang, Y.; Zhao, L.; Zhang, G.; Qu, P.; et al. A naphthalimide-based chemodosimetric probe for ratiometric detection of hydrazine. Sens. Actuators B Chem. 2017, 244, 417–424. [Google Scholar] [CrossRef] [Scilit]
- Lai, Y.; Zhang, T.; Huang, L.; Li, W.; Lin, W. Monitoring cell viability in N-nitrosodiethylamine induced acute hepatitis and detection of hydrazine in solution and gas phase with Dual-function fluorescent probes. J. Hazard. Mater. 2023, 443, 130207. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jiang, W.-K.; Wang, X.; Wu, W.-N.; Bian, L.-Y.; Fan, Y.-C.; Wang, Y.; Xu, Z.-H.; Zeng, L. A distinctive merocyanine-based fluorescent probes for the detection of phosgene and hydrazine. J. Hazard. Mater. 2025, 500, 140466. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Qi, Y.-L.; Chen, J.; Zhang, B.; Li, H.; Li, D.-D.; Wang, B.-Z.; Yang, Y.-S.; Zhu, H.-L. A turn-on fluorescent sensor for selective detection of hydrazine and its application in Arabidopsis thaliana. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2020, 227, 117707. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, M.; Gu, Y.; Zhao, M.; Zhang, S.; Wang, S.; Wang, Z. Design of a red-emitting camphor-derived benzothiazole ratiometric fluorescent probe for hydrazine detection in environmental samples and its versatile imaging applications in live cells, zebrafish and Arabidopsis thaliana. Talanta 2027, 312, 130354. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sun, X.-Y.; Hua, F.-F.; Bai, T.-W.; Fu, Y.-L. Development of red fluorescent probe for visual detection of N2H4 via nanofiber membrane and its application in environmental analysis and biological imaging. Sens. Actuators B Chem. 2025, 423, 136807. [Google Scholar] [CrossRef] [Scilit]
- Shen, D.; Song, C.; Liu, L.; Li, H.; Ju, Y.; Jing, W.; Wang, H. Key-enabled molecular rotation modulates intramolecular hydrogen bonding toward a turn-on trace-level N2H4 sensor. Anal. Methods 2025, 17, 6061–6072. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xiao, W.; Zhang, Q.; You, D.H.; Xue, W.; Peng, F.; Li, N.B.; Zhou, G.M.; Luo, H.Q. Myricetin-based fluorescence probes with AIE and ESIPT properties for detection of hydrazine in the environment and fingerprinting. Anal. Chim. Acta 2024, 1288, 342173. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Karakus, A.C.; Karakuş, E. A novel flavone-based fluorescent probe for hydrazine detection in aqueous, soil and cell environments. J. Hazard. Mater. Adv. 2026, 21, 101083. [Google Scholar] [CrossRef] [Scilit]
- Zhu, D.; Rajalakshmi, K.; Wang, R.; Wu, H.; Kannan, P.; Song, J.-W.; Lee, H.-J.; Muthusamy, S. A coumarin derivative-based turn-on fluorescent probe for real-time applications of hydrazine detection in environment and bioimaging. Dye. Pigment. 2023, 216, 111370. [Google Scholar] [CrossRef] [Scilit]
- Hao, D.; Gao, X.; Chu, Q.; Xu, H. A hydrophilic quinoline-based fluorescent probe for hydrazine detection and its application in real water samples and cell imaging. Dye. Pigment. 2026, 251, 113761. [Google Scholar] [CrossRef] [Scilit]
- Muthusamy, S.; Yin, S.; Rajalakshmi, K.; Meng, S.; Zhu, D.; Xie, M.; Xie, J.; Lodi, R.S.; Xu, Y. Development of a quinoline-derived turn-on fluorescent probe for real time detection of hydrazine and its applications in environment and bioimaging. Dye. Pigment. 2022, 206, 110618. [Google Scholar] [CrossRef] [Scilit]
- Cui, Y.; Xu, C.; Wu, T.; Nie, Y.; Zhou, Y. Near-infrared cyanine-based fluorescent probe: Rapidly visualizing the in situ release of hydrazine in living cells and zebrafish. Sens. Actuators B Chem. 2022, 350, 130878. [Google Scholar] [CrossRef] [Scilit]
- Ruan, M.; Zhang, B.; Wang, J.; Fan, G.; Lu, X.; Zhang, J.; Zhao, W. A resorufin-based fluorescent probe for hydrazine detection and its application in environmental analysis and bioimaging. Anal. Methods 2023, 15, 6412–6416. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Song, Q.; Wang, N.; Wang, F.; Guo, K.; Cui, J.; Hao, J.; Zhang, Y.-Q.; Jiang, J. A highly selective NIR ratiometric fluorescent probe for in situ detection of metabolized hydrazine in living cells. Sens. Actuators B Chem. 2023, 393, 134164. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Huang, Y.; Yang, G.; Xin, H.; Li, K.; Wang, L.; Gu, S.; Ren, B.; Zhao, S.; Cao, D. Application of a fluorescent probe exhibiting a large stokes shift after the precise detection of hydrazine in plants, foods and living cells. J. Hazard. Mater. 2025, 502, 137452. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lu, G.; Yu, S.; Duan, L.; Meng, S.; Ding, S.; Dong, T. New 1,8-naphthalimide-based colorimetric fluorescent probe for specific detection of hydrazine and its multi-functional applications. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2024, 305, 123450. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Oguz, M.; Erdemir, S.; Malkondu, S. Engineering a “turn-on” NIR fluorescent sensor-based hydroxyphenyl benzothiazole with a cinnamoyl unit for hydrazine and its environmental and in-vitro applications. Environ. Pollut. 2024, 343, 123193. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ma, J.; Kong, X.; Zhao, M.; Jiao, Z.; Zhang, X.; Xie, H.; Zhang, Z. A water-soluble red-emitting fluorescence probe for detecting hazardous hydrazine in environmental waters and biosystems. Sci. Total Environ. 2024, 944, 173810. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cao, T.; Ma, H.; Zheng, L.; Lu, W.; Fan, Z. A ratiometric fluorescent probe for hydrazine imaging in biological and environmental samples. Chin. J. Anal. Chem. 2023, 51, 100293. [Google Scholar] [CrossRef] [Scilit]
- Lalitha, R.; Wu, S.P.; Velmathi, S. Two Benzocoumarin-based hydrazine chemodosimeters and their application in monitoring trace levels of hydrazine in soil, water, and urine samples. J. Photochem. Photobiol. A Chem. 2023, 442, 114795. [Google Scholar] [CrossRef] [Scilit]
- Xu, Y.-X.; Song, Y.-M.; Chen, C.-Y.; Shen, J.-W.; Zhu, H.-L. A pH-Applicative Fluorescent Probe with Long Measuring Range for Monitoring Hydrazine in Water Samples and Arabidopsis thaliana. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2022, 270, 120758. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, K.-B.; Chen, Y.; Zhou, T.; Wang, T.; Wu, D.; Pan, Y.; Zhang, S.; Shi, W.; Wang, F.; Ren, J. Chloro-hydroxyl-merocyanine based turn-on fluorescent probes for the detection of hydrazine in water and living cells. Dye. Pigment. 2022, 200, 110109. [Google Scholar] [CrossRef] [Scilit]
- Liu, J.; Wang, J.; Hou, X.; Dong, Z.; Wang, Y.; Shuang, S. A novel mitochondria targeting near-infrared fluorescent probe for specific visualization of toxic hydrazine in aqueous environments, live cells and zebrafish. J. Mol. Struct. 2026, 1356, 145083. [Google Scholar] [CrossRef] [Scilit]
- Fan, F.; Xu, C.; Liu, X.; Zhu, M.; Wang, Y. A novel ESIPT-based fluorescent probe with dual recognition sites for the detection of hydrazine in the environmental water samples and in-vivo bioimaging. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2022, 280, 121499. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tang, L.; Zhou, L.; Liu, A.; Yan, X.; Zhong, K.; Liu, X.; Gao, X.; Li, J. A new cascade reaction-based colorimetric and fluorescence “turn on” dual-function probe for cyanide and hydrazine detection. Dye. Pigment. 2021, 186, 109034. [Google Scholar] [CrossRef] [Scilit]
- Xu, Y.; Yang, L.; Jin, C.; Zhu, H.-L.; Yan, H.; Li, Z. Development and application of a novel fluorescence probe for sensitive detection of hydrazine hydrate in environmental and biological samples. Mater. Today Chem. 2024, 42, 102410. [Google Scholar] [CrossRef] [Scilit]
- Fu, D.; Zhong, H.; Xiao, J.; Meng, J. The repurposing 4-hydroxy thalidomide-derived fluorescent probe for hydrazine response and its application in bioimaging of hydrazine as a metabolite in zebrafish. J. Mol. Struct. 2026, 1373, 146703. [Google Scholar] [CrossRef] [Scilit]
- Lai, Q.; Si, S.; Qin, T.; Li, B.; Wu, H.; Liu, B.; Xu, H.; Zhao, C. A novel red-emissive probe for colorimetric and ratiometric detection of hydrazine and its application in plant imaging. Sens. Actuators B Chem. 2020, 307, 127640. [Google Scholar] [CrossRef] [Scilit]
- Qiu, X.-Y.; Liu, S.-J.; Hao, Y.-Q.; Sun, J.-W.; Chen, S. Phenothiazine-based fluorescence probe for ratiometric imaging of hydrazine in living cells with remarkable Stokes shift. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2020, 227, 117675. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, J.-Y.; Liu, Z.-R.; Ren, M.; Lin, W. 2-benzothiazoleacetonitrile based two-photon fluorescent probe for hydrazine and its bio-imaging and environmental applications. Sci. Rep. 2017, 7, 1530. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, T.; Zhu, L.; Lin, W. A near Infrared Ratiometric Fluorescent Probe with Aggregation Induced Emission (AIE) Characteristics for Hydrazine Detection in Vitro and in Vivo. Dye. Pigment. 2021, 188, 109177. [Google Scholar] [CrossRef] [Scilit]
- Li, Z.; Zhang, W.; Liu, C.; Yu, M.; Zhang, H.; Guo, L.; Wei, L. A Colorimetric and Ratiometric Fluorescent Probe for Hydrazine and Its Application in Living Cells with Low Dark Toxicity. Sens. Actuators B Chem. 2017, 241, 665–671. [Google Scholar] [CrossRef] [Scilit]
- Wu, J.; Pan, J.; Ye, Z.; Zeng, L.; Su, D. A Smart Fluorescent Probe for Discriminative Detection of Hydrazine and Bisulfite from Different Emission Channels. Sens. Actuators B Chem. 2018, 274, 274–284. [Google Scholar] [CrossRef] [Scilit]
- Li, J.; Cui, Y.; Bi, C.; Feng, S.; Yu, F.; Yuan, E.; Xu, S.; Hu, Z.; Sun, Q.; Wei, D.; et al. Oligo(ethylene glycol)-Functionalized Ratiometric Fluorescent Probe for the Detection of Hydrazine in Vitro and in Vivo. Anal. Chem. 2019, 91, 7360–7365. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shan, X.; Wu, S.; Shen, L.; Peng, S.; Xu, H.; Wang, Z.-Y.; Yang, X.-J.; Huang, Y.-L.; Feng, X.; Redshaw, C.; et al. Ratiometric red aggregation-induced emission luminogens for hydrazine hydrate detection. Dye. Pigment. 2023, 219, 111609. [Google Scholar] [CrossRef] [Scilit]
- Yu, X.; Zhang, H.; Chao, M.; Cui, X.; Zhu, X.; Chen, X. A novel donor-π-acceptor type bridge fluorescence probe for the detection of hydrazine based on thiophene and its application in soil, water, cell imaging and electrospinning films. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2025, 341, 126468. [Google Scholar] [CrossRef] [Scilit]
- Hou, Y.; Xu, R.; Hou, Y.; Chen, B. Development of a D-π-A dual-mode probe for highly sensitive and selective hydrazine detection: Towards multifunctional applications and molecular sequential logic gate. J. Photochem. Photobiol. A Chem. 2027, 483, 117631. [Google Scholar] [CrossRef] [Scilit]
- Huang, J.; Zhou, Y.; Wang, W.; Zhu, J.; Li, X.; Fang, M.; Wu, Z.; Zhu, W.; Li, C. A fluorescent probe based on triphenylamine with AIE and ICT characteristics for hydrazine detection. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2023, 286, 122011. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chen, R.; Li, B.; Qin, X.; Xing, S.; Ren, H.; Ma, F.; Chen, J.; Niu, Q. A new carbazole based fluorescent probe with AIE characteristic for detecting and imaging hydrazine in living cells, mungbean sprouts, Arabidopsis thaliana, and practical samples. Talanta 2024, 273, 125953. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Zeng, F.; Wu, S. Carbazole-xanthene-based swab/film fluorescent sensors for on-site visual detection of hydrazine in environmental and agricultural samples. Anal. Methods 2025, 17, 8889–8897. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, C.; Tang, S.; Wu, J.; Lv, W.; Li, J.; Tang, C. A new indoloquinoline-based fluorescence probe for imaging of hydrazine in vitro and in vivo. RSC Adv. 2026, 16, 13943–13948. [Google Scholar] [CrossRef] [Scilit]
- Shangguan, H.; Niu, P.; Teng, Z.; Liu, X.; Sun, A.; Wei, L. Construction of fluorescent probe based on phenoxazine for the detection of N2H4 in environmental, biological and food samples. Microchem. J. 2024, 207, 111798. [Google Scholar] [CrossRef] [Scilit]
- Tang, C.; Tong, H.; Liu, B.; Wang, X.; Jin, Y.; Tian, E.; Wang, F. Robust ERα-Targeted Near-Infrared Fluorescence Probe for Selective Hydrazine Imaging in Breast Cancer. Anal. Chem. 2022, 94, 14012–14020. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, Q.-X.; Yuan, Y.-J.; Cheng, R.-X.; Ma, Y.; Tan, R.; Wang, Y.-W.; Peng, Y. An AIE-active tetra-aryl imidazole-derived chemodosimeter for turn-on recognition of hydrazine and its bioimaging in living cells. Org. Biomol. Chem. 2024, 22, 6135–6140. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pandey, D.; Imran, K.; Yadav, R.K.; Kaur, J.; Naqvi, S.; Sharma, A. Push-pull intramolecular charge transfer solvatofluorochromic fluorophore for the selective and real-time detection of hydrazine. Microchem. J. 2023, 191, 108912. [Google Scholar] [CrossRef] [Scilit]
- Dong, F.; Zhang, C.; Fu, Y.; Wang, W.-L. Novel near-infrared 2H-chromene-based ratiometric fluorescent probe: Rapidly monitoring hydrazine in real samples. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2025, 340, 126225. [Google Scholar] [CrossRef] [Scilit]
- Gao, H.; Wang, L.; Zhang, C.; Tian, S.; Duan, H. A novel “turn-on” fluorescent probe DPP-BR based on pyrrolopyrrole diketone for imaging hydrazine in soil, vegetables, Arabidopsis thaliana, cells, and zebrafish. Sens. Actuators B Chem. 2026, 451, 139252. [Google Scholar] [CrossRef] [Scilit]
- Xu, R.; Hou, Y.; Hou, Y.; Chen, B. Rapid and specific detection of hydrazine in environmental samples with a malononitrile functionalized DTTO probe and smartphone based analysis. Talanta 2026, 310, 130084. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xiong, L.; Li, W.; Xie, Z.; Wang, B.; Feng, G. A malononitrile-based portable fluorescent probe for ultrasensitive detection of hydrazine in environmental matrices. Talanta 2026, 297, 128607. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, D.-P.; Zhang, P.; Guo, X.; Zhang, T.; Ran, X.; Zhang, T.; Xiao, H.; Shu, W. A new fluorescent probe for detection of hydrazine and extremely acidic pH in different modes. Tetrahedron 2024, 159, 134007. [Google Scholar] [CrossRef] [Scilit]
- Cansever, O.; Erdemir, G.Y. Design, Synthesis, and Aggregation-Induced Emission Properties of a Novel D-π-A Conjugated Molecule as a Selective Hydrazine Sensor. ACS Omega 2025, 10, 45671–45679. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xiao, F.; Dong, J.; Zhu, R.; Bai, H.; Zhao, C.; Zu, B.; Cui, Y.; Cai, Z. Zero- Fluorescence Probe for Ultrasensitive and Specific Detection of Hydrazine by Regulating the Electron-Accepting Strength. Anal. Chem. 2025, 97, 8939–8946. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sreelaya, V.; Drisya, V.; Chakkumkumarath, L. A pyrene-based fluorescent sensor for the discrimination and estimation of hydrazine and hydrogen sulfide and its application in assessing food spoilage. J. Hazard. Mater. 2025, 487, 137151. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kong, X.; Li, M.; Zhang, Y.; Yin, Y.; Lin, W. Engineering an AIE N2H4 fluorescent probe based on α-cyanostilbene derivative with large Stokes shift and its versatile applications in solution, solid-state and biological systems. Sens. Actuators B Chem. 2021, 329, 129232. [Google Scholar] [CrossRef] [Scilit]
- Chang, W.; Yang, W.; Wang, X.; Xu, F.; Zhang, W.; Qian, J. Colorimetric and ratiometric fluorescent probes for sensitive visualization of hydrazine in water and in living cells. Anal. Methods 2025, 17, 8120–8126. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Erdemir, S.; Oguz, M.; Malkondu, S.; Kocak, A. Portable and rapid hydrazine monitoring by a large Stokes shift probe with smartphone-assisted quantification: Its real-sample applications. Environ. Pollut. 2026, 406, 128703. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, T.; Lai, Y.; Lin, W. Design of a ratiometric near-infrared fluorescent probe with double excitation for hydrazine detection in vitro and in vivo. Sci. Total Environ. 2022, 837, 155462. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Liang, Y.; Xu, T.; Yue, X.; Xu, S.; Xu, X.; Wang, S.; Wang, Z. A near-infrared ratiometric fluorescent probe for simultaneous detection of hydrazine and hypochlorous acid in biological systems and its portable detection in environmental samples using a smartphone. J. Hazard. Mater. 2025, 488, 137425. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bartwal, G.; Manivannan, R.; Patra, S.K.; Choi, Y.; Son, Y.-A. A triple-chromophore based NIR fluorescent chemodosimeter with configurable opto-chemical logic gate functions for multi-analyte recognition of N2H4, CN−, and ClO− in real samples. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2025, 339, 126250. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Du, M.; Zhang, Y.; Xu, Z.; Dong, Z.; Zhao, S.; Du, H.; Zhao, H. Point-of-Care and Dual-Response Detection of Hydrazine/Hypochlorite-Based on a Smart Hydrogel Sensor and Applications in Information Security and Bioimaging. Molecules 2023, 28, 3896. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xu, C.; Zhang, Y.; Ren, M.; Liu, K.; Wu, Q.; Zhang, C.; Kong, F. Near-infrared dual-response fluorescent probe for detection of N2H4 and intracellular viscosity changes in biological samples and various water samples. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2024, 314, 124180. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gong, Z.; Yue, L.; Tan, Z.; Wu, Y.; Huang, Y.; Ding, H.; Fan, C.; Liu, G.; Pu, S. Development of a novel AIEE fluorescent probe for hydrazine based on diarylethene and its applications in invisible two-dimensional code. Microchem. J. 2025, 209, 112598. [Google Scholar] [CrossRef] [Scilit]
- Sun, Y.; Zou, J.; Guan, L.; Li, Y.; Wu, X.; Liu, H.; Chen, Z.; Liu, G.; Pu, S. Tetraaryl-functionalized hydrazine-responsive fluorescent materials with aggregation-induced emission and Photochromism for chemical sensing and time-dependent dynamic anti-counterfeiting. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2026, 345, 126774. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yi, Q.; He, J.; Fu, X.; Ying, J.; Gong, L.; Shen, J.; He, X. Carbazole-based chemosensor for highly sensitive and selective bioimaging identification of hydrazine in multiple model systems via ratiometric and colorimetric. Dye. Pigment. 2021, 196, 109816. [Google Scholar] [CrossRef] [Scilit]
- Chen, L.; Lv, B.; Wang, Z.; Sun, L.; Sun, X.; Li, J.; Gu, W. A novel ratiometric NIR fluorescent probe based on tanshinone IIA with double excitation for the detection of hydrazine. Dye. Pigment. 2023, 220, 111680. [Google Scholar] [CrossRef] [Scilit]
- Shi, J.; Tan, H.; Wang, Z.; Yang, X.; Rao, X.; Zhao, P.; Jiang, Q. Phenanthroimidazole-based fluorescence probe for discriminative detecting of hydrazine and bisulfite and its applications in environmental samples. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2024, 321, 124747. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huang, Y.; Liang, J.; Fan, Z. Phenothiazine-based multifunctional fluorescent probe for one-site rapid detection of hydrazine in cells, soil, water samples and test strip. Dye. Pigment. 2023, 220, 111164. [Google Scholar] [CrossRef] [Scilit]
- Wang, Y.; Wang, C.; Zheng, Y.; Wang, Y.; Li, Y.; Niu, H. A dual-mode colorimetric and fluorescent probe for hydrazine enabling smartphone-assisted hydrogel sensing and anti-counterfeiting. Dye. Pigment. 2026, 252, 113785. [Google Scholar] [CrossRef] [Scilit]
- Peng, X.; Jiang, C.-C.; Liu, Y.-K.; Xiao, J.-R.; Jiang, L.; Qin, B.-B.; Rim, S.A.; Chen, X.-Y.; Wang, J.-Y. A deep-red fluorescent probe for differential detection: Simple sensing of hydrazine in food and plants and smartphone-based monitoring of peroxynitrite. Talanta 2026, 302, 129391. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kalel, R.A.; Ware, A.P.; Pingale, S.S. Ethyl 2-cyano-3-(naphthalene-1-yl) acrylate (ECNA): A sensitive, selective fluorescence ‘turn-off’ chemodosimeteric probe for the detection of poisonous hydrazine hydrate and its vapour. New J. Chem. 2025, 49, 5126–5138. [Google Scholar] [CrossRef] [Scilit]
- Zeng, C.; Xu, Z.; Song, C.; Qin, T.; Jia, T.; Zhao, C.; Wang, L.; Liu, B.; Peng, X. Naphthalene-based fluorescent probe for on-site detection of hydrazine in the environment. J. Hazard. Mater. 2023, 445, 130415. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zafar, M.M.; Sahoo, S.C.; Praveen, V.K.; Tyagi, N.; Mishra, R.K. Imidazole-assisted film-based fluorescent sensor for the ultrasensitive detection of hydrazine. J. Mater. Chem. C 2024, 12, 7472–7481. [Google Scholar] [CrossRef] [Scilit]
- Jin, Y.; Sun, R.; Li, G.; Yuan, M.; Shao, W.; Gao, M.; Yuan, C.; Wang, S. Water-soluble single molecular probe for simultaneous detection of viscosity and hydrazine. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2023, 294, 122558. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, S.; Tian, J.; Gong, S.; Meng, Z.; Liang, Y.; Gu, Y.; Wang, M.; Wang, Z.; Wang, S. A novel biphenyl tetrahydroindazole-type fluorescent probe for the detection of hydrazine and its applications in food detection, environmental analysis and biological imaging. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2026, 347, 126966. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, L.; Xin, S.; Xie, F.; Ran, X.; Tang, H.; Cao, D. A novel windmill-shaped AIE-active pyrrolopyrrole cyanine: Design, synthesis and efficient hydrazine detection. J. Mater. Chem. C 2022, 10, 14605–14615. [Google Scholar] [CrossRef] [Scilit]
- Lai, B.; Xiao, Y.; Ran, X.; Cao, D.; Wang, L. A “two-in-one” pyrrolopyrrole cyanine fluorescent probe for discriminative detection of hydrazine and hydrogen sulfide in real samples. J. Mater. Chem. C 2026, 14, 4556–4573. [Google Scholar] [CrossRef] [Scilit]
- Oguz, M.; Erdemir, S.; Malkondu, S. An effective benzothiazole-indandione D-π-A fluorescent sensor for “ratiometric” detection of hydrazine: Its solvatochromism properties and applications in environmental samples and living cells. Anal. Chem. Acta 2022, 1227, 340320. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Su, H.; Wang, J.; Yue, X.; Wang, B.; Song, X. A ratiometric fluorescent probe with large Stokes shift and emission shift for sensing hydrazine in living organisms. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2022, 274, 121096. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shen, Z.; Yang, Y.; Gu, Y.; Wang, Z.; Wang, S. Carbazole-pyrimidine-based novel ratiometric fluorescent probe with large Stokes shift for detection of hydrazine in real environments and organisms. J. Hazard. Mater. 2025, 482, 136593. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, T.; Ma, W.; Xing, S.; Wang, X.; Ren, H.; Hu, T.; Niu, Q.; Chen, J.; Ding, Y. A new phenoxazine-indanedione turn-on fluorescent probe with ultra-sensitivity for detecting hydrazine and its application in drinks, human urine and water samples and colorimetric test strips. J. Mol. Liq. 2024, 408, 125248. [Google Scholar] [CrossRef] [Scilit]
- Kong, Y.-Y.; Han, D.; Shi, X.-Y.; Yang, H.-K.; Liu, Z.; Lin, J.-T.; Xia, H.-C. A dual-channel fluorescent probe for differential detection of HClO and N2H4. J. Mol. Struct. 2025, 1321, 140176. [Google Scholar] [CrossRef] [Scilit]
- Yuan, Z.; Zhang, Y.; Du, Y.; Dong, J.; Zhang, J.; Xing, Z. A colorimetric and fluorescent dual-mode sensor for the visualization of hydrazine. J. Photochem. Photobiol. A Chem. 2026, 474, 117020. [Google Scholar] [CrossRef] [Scilit]
- Li, Y.; Jiang, X.; Yan, X.; Zhong, K.; Sun, X.; Li, J.; Tang, L. A dual-channel ICT fluorescent probe assisted by smartphone for quantitative detection, and visualization of residual hydrazine in the living cells, water, soil, plant, and food samples. Anal. Chim. Acta 2024, 1327, 343163. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shang, Z.; Tian, S.; Wang, Y.; Zhang, C.; Meng, Q.; Zhang, R.; Zhang, Z. 1,8-naphthalimide-triphenylamine-based red-emitting fluorescence probes for the detection of hydrazine in real water samples and applications in bioimaging in vivo. Sens. Actuators B Chem. 2024, 398, 134725. [Google Scholar] [CrossRef] [Scilit]
- Xia, H.-C.; Wang, H.-H.; Han, D.; Yang, H.-K.; Lv, J.-L.; Kong, Y.-Y. Phenothiazine-based fluorescent probes for the detection of hydrazine in environment and living cells. Talanta 2024, 269, 125448. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, X.-H.; Li, M.-Z.; Yang, X.-Y.; Wang, T.-Y.; Luo, Y.-H.; Kandegama, W.; Li, J.-Y.; Hao, G.-F.; Liu, C.-R. Ultra-sensitive, versatile and portable detection of hydrazine in eco-environmental systems using a smartphone-integrated ratiometric fluorescent sensor. J. Hazard. Mater. 2025, 492, 138172. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chen, R.; Hu, T.; Xing, S.; Wei, T.; Chen, J.; Li, T.; Niu, Q.; Zhang, Z.; Ren, H.; Qin, X. A dual-responsive fluorescent turn-on sensor for sensitively detecting and bioimaging of hydrazine and hypochlorite in biofluids, live-cells, and plants. Anal. Chim. Acta 2023, 1239, 340735. [Google Scholar] [CrossRef] [Scilit]
- Suna, G.; Gunduz, S.; Topal, S.; Ozturk, T.; Karakuş, E. A unique triple-channel fluorescent probe for discriminative detection of cyanide, hydrazine, and hypochlorite. Talanta 2023, 257, 124365. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lv, B.; Wang, Z.; Wu, Y.; Zheng, Y.; Cui, Z.; Li, J.; Gu, W. A novel dual-responsive colorimetric/fluorescent probe for the detection of N2H4 and ClO− and its application in environmental analysis and bioimaging. J. Hazard. Mater. 2024, 469, 134105. [Google Scholar] [CrossRef] [Scilit]
- Wang, B.; Quinto, M.; He, W.; Qiu, H.; Li, X.; Zhao, W. Visual monitoring of hydrazine in food and environmental samples by wearable probe. J. Hazard. Mater. 2024, 480, 136384. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, B.; He, W.; Li, X.; Zhao, W.; Qiu, H.; Zhang, H. Engineering a fluorescent probe for the visual and wearable detection of N2H4 in foods, environment samples and biological imaging. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2025, 327, 125365. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bian, Y.; Zhao, X.; He, W.; Zhao, W.; Wang, B. A colorimetric/fluorescent dual-mode probe for real-time hydrazine detection in biological, food, and environmental samples. Tetrahedron 2025, 187, 134945. [Google Scholar] [CrossRef] [Scilit]
- Fang, H.; Qiao, Z.; Sui, X.; Quinto, M.; He, W.; Zhao, W.; Wang, B. Engineering a dual-response fluorescent probe for bioimaging of hypochlorous acid and hydrazine in foods, plants, cells and bacteria. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2026, 346, 126911. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pise, S.; Dey, N. One probe, two chemistries: An orthogonal fluorescent sensing platform for glutathione and hydrazine in biological fluids and food samples. J. Mater. Chem. B 2026, 14, 7615–7629. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gu, Y.; Gong, S.; Zhao, M.; Tian, J.; Meng, Z.; Liang, Y.; Gao, L.; Wang, Z.; Wang, S. Novel barbituric acid-fused acridine-based hydrogel AIE fluorescent sensor for ultrasensitive on-site detection and efficient removal of hydrazine in gaseous and water environments. Sens. Actuators B Chem. 2026, 449, 139106. [Google Scholar] [CrossRef] [Scilit]
- Ma, W.; Xing, S.; Liu, J.; Wei, T.; Niu, Q.; Hu, T.; Chen, J.; Li, T. A novel phenoxazine-Meldrum’s acid D-π-A fluorescent sensor for “turn-on” detecting hydrazine and its applications to practical samples analysis, plant and animal imaging. Sens. Actuators B Chem. 2022, 350, 130850. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Jiang, X.; Wang, Z.; Li, Y.; Ren, J.; Zhong, K.; Li, X.; Tang, L.; Li, J. Fluorescent probe for imaging N2H4 in plants, food, and living cells and for quantitative detection of N2H4 in soil and water using a smartphone. J. Hazard. Mater. 2024, 479, 135701. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, C.-L.; Liu, C.; Nie, S.-R.; Zhang, Y.; Guo, J.-H.; Liu, C. A novel near-infrared fluorescence probe for detecting N2H4 and its application in natural environment and biological system. Dye. Pigment. 2024, 224, 111966. [Google Scholar] [CrossRef] [Scilit]
- Pan, Y.; Tang, L.; Li, L.; Wu, X.; Yan, L. A versatile fluorescent probe for the ratiometric detection of hydrazine (N2H4) in water, soil, plant, and food samples. Environ. Pollut. 2024, 359, 124766. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, S.; Li, Y.; Lin, Q.; Wen, W.; Xu, X. Portable fluorescent probe for on-site visual detection and quantification of hydrazine and viscosity in environmental and food samples. Dye. Pigment. 2026, 248, 113564. [Google Scholar] [CrossRef] [Scilit]
- Rout, A.; Mondal, S.; Manna, S.K.; Mukhopadhyay, S. A simple ratiometric fluorogenic and chromogenic chemodosimeter for hydrazine detection in pure aqueous solution: Applications in food and soil samples, along with smartphone-based sensing systems. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2026, 348, 127256. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yang, J.; Xu, X.; Yan, L.; Wu, X. A fluorescent probe based on benzothiazole and benzoindole for detecting hydrazine in various applications. New J. Chem. 2025, 49, 5420–5426. [Google Scholar] [CrossRef] [Scilit]
- Tang, L.; Xu, X.; Yan, L.; Wu, X.; Li, L. A ratiometric fluorescent probe for hydrazine and its application in hydrogel detection platform. Dye. Pigment. 2025, 238, 112724. [Google Scholar] [CrossRef] [Scilit]
- Lai, H.-J.; Wang, X.; Wang, Y.; Wu, W.-N.; Xu, Z.-H. A Golgi-targeting fluorescent probe for the detection of hydrazine in biological and environmental systems. Anal. Methods 2025, 17, 6317–6325. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Subramani, U.; Rajamanikandan, R.; Mani, K.S. Coumarin hemicyanine-based colorimetric, smartphone color ratio, and intramolecular charge transfer fluorescent receptor for highly specific sensing of hydrazine in environmental water samples. J. Mol. Liq. 2023, 385, 122442. [Google Scholar] [CrossRef] [Scilit]
- Ye, Q.; Meng, Z.; Zhang, S.; Yao, Q.; Luo, Y.; Wang, Z.; Wang, S. A novel fluorescent probe based on acridine derivatives for rapid and specific detection of N2H4 and its application in environment and biological imaging. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2025, 343, 126561. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, B.; Ma, F.; Li, Y.; Hu, T.; Niu, Q.; Chen, J. A new D-π-A-type fluorescent probe for sensitive and quantitative monitoring and bioimaging of N2H4 in various water/soil samples, living cells, plants and zebrafish. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2026, 345, 126814. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, Y.; Gan, Y.; Lai, B.; Ran, X.; Cao, D.; Wang, L. A portable sensing platform using a novel dipyrrolopyrazinedione-based aza-BODIPY dimer for highly efficient detection of hypochlorite and hydrazine. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2025, 341, 126415. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, T.; Ding, Y.; Wei, T.; Hu, T.; Chen, J.; Niu, Q. A dual-platform phenothiazine-based fluorescent probe for hydrazine (N2H4) bioimaging in multiple organisms and smartphone-assisted environmental monitoring. J. Hazard. Mater. 2026, 501, 140905. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Erdemir, S.; Malkondu, S.; Oguz, M.; Kocyigit, O. A novel pathway for ratiometric hydrazine sensing in environmental samples and the detection of intracellular viscosity by a mitochondria-targeted fluorescent sensor. Talanta 2024, 267, 125143. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Meher, N.; Panda, S.; Kumar, S.; Lyer, P.K. Aldehyde group driven aggregation-induced enhanced emission in naphthalimides and its application for ultradetection of hydrazine on multiple platforms. Chem. Sci. 2018, 9, 3978–3985. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jung, Y.; Ju, I.G.; Choe, Y.H.; Kim, Y.; Park, S.; Hyun, Y.M.; Oh, M.S.; Kim, D. Hydrazine Exposé: The Next-Generation Fluorescent Probe. ACS Sens. 2019, 4, 441–449. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yang, N.-X.; Xiong, B.-X.; Zhang, Y.-T.; Wu, J.-F.; Liu, B.-H.; Wu, M.-N.; Han, X.-F.; Bian, L.-Y.; Wang, Y. N-(2-formylphenyl)-4-methylbenzenesulfonamide: A simple endoplasmic reticulum-targetable probe for the ratiometric fluorescent detection of hydrazine in environmental and biological systems. Microchem. J. 2024, 205, 111251. [Google Scholar] [CrossRef] [Scilit]
- Vijay, N.; Balamurugan, G.; Natesan, T.; Naveen, K.R.; Oh, T.H. A tandem approach for simultaneous detection of toxic hydrazine and phosgene in the environment. Anal. Chim. Acta 2026, 1396, 345256. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Santos, C.O.; Passos, S.T.A.; Sorto, J.E.P.; Machado, D.F.S.; Correa, J.R.; da Silva Júnior, E.N.; Rodrigues, M.O.; Neto, B.A.D. Sensitive hydrazine detection and quantification with a fluorescent benzothiadiazole sensor: Selective lipid droplets and in vivo imaging. Org. Biomol. Chem. 2023, 21, 4606–4619. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Han, Y.; Huang, Y.; Lin, Q.; Tang, L.; Yang, G.; Xin, H.; Zhao, S.; Guan, R.; Wang, K.-N.; Cao, D. Bifunctional fluorescent probe for the recognition of hydrazine and bisulfite in lipid droplets. Sens. Actuators B Chem. 2023, 393, 134181. [Google Scholar] [CrossRef] [Scilit]
- Shan, L.; Li, X.; Yu, Z.; Zheng, X.; Ren, H.; Wu, J.; Lv, C.; Wang, P.; Liu, W. Coumarin bialdehyde-based fluorescent probe for the detection of hydrazine in living cells, soil samples and its application in test strips. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2025, 343, 126540. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yang, Y.Z.; Qing, M.; Luo, X.Y.; Xie, J.; Zhang, L.N. A dual-response fluorescent probe for discriminative sensing of hydrazine and bisulfite as well as intracellular imaging with different emission. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2022, 270, 120795. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Guo, Z.; Wang, M.; Li, X.; Jia, X.; Wang, X.; Zhang, P.; Wei, C.; Li, X. A Hepatocyte-Targeting Fluorescent Probe for Imaging Isoniazid-Induced Hydrazine in HepG2 Cells and Zebrafish. Chem. Commun. 2020, 56, 14183–14186. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, L.; Liu, F.-Y.; Liu, H.-Y.; Dong, Y.-S.; Liu, T.-Q.; Liu, J.-F.; Yao, Y.-W.; Wan, X.-J. A Novel Pyrazoline-Based Fluorescent Probe for Detection of Hydrazine in Aqueous Solution and Gas State and Its Imaging in Living Cells. Sens. Actuators B 2016, 229, 441–452. [Google Scholar] [CrossRef] [Scilit]
- Yan, S.; Guo, H.; Tan, J.; Jiang, J.; Liang, J.; Yan, S.; Xiao, H. Two novel spirobifluorene-based two-photon fluorescent probes for the detection of hydrazine in solution and living cells. Talanta 2020, 218, 121210. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chen, Y.; Mo, W.; Cheng, Z.; Kong, F.; Chen, C.; Li, X.; Ma, H. A portable system based on turn-on fluorescent probe for the detection of hydrazine in real environment. Dye. Pigment. 2022, 198, 110004. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Xu, C.; Sun, H.; Ai, J.; Ren, M. A turn-on fluorescent probe for sensing N2H4 in living cells, zebrafishes and plant root with a large turn-on fluorescence signal. Talanta 2023, 265, 124902. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Saygili, E.; Kibris, E.; Gelen, S.S.; Eldem, A.; Odaci, D.; Ucuncu, M. A novel phenalenone-based probe for dual-mode hydrazine detection. Microchem. J. 2025, 215, 114263. [Google Scholar] [CrossRef] [Scilit]
- Zou, H.; Lin, G.; Bao, Y.; Liang, J.; Li, Y.; Cai, L.; Wu, H.-Y.; Yang, F.; Chen, H.; Lin, X.; et al. Dual-emission fluorescent probe with sequential two-step ESIPT activation mechanism for selective hydrazine detection and multifunctional applications. J. Hazard. Mater. 2025, 493, 138388. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xing, M.; Han, Y.; Zhu, Y.; Sun, Y.; Shan, Y.; Wang, K.-N.; Liu, Q.; Dong, B.; Cao, D.; Lin, W. Two Ratiometric Fluorescent Probes Based on the Hydroxyl Coumarin Chalcone Unit with Large Fluorescent Peak Shift for the Detection of Hydrazine in Living Cells. Anal. Chem. 2022, 94, 12836–12844. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, L.; Yang, G.; Zhang, C.; Fan, J.; Ren, B.; Cao, D. Dually responsive NIR fluorescent probe for integrated sensing of hydrazine and polarity in environmental systems. J. Mol. Struct. 2026, 1351, 144338. [Google Scholar] [CrossRef] [Scilit]
- Erdemir, S.; Malkondu, S.; Oguz, M. Fast, visual, and quantitative monitoring of N2H4 by two ratiometric fluorescent probes in environmental media and biological systems. Chem. Eng. J. 2023, 468, 143767. [Google Scholar] [CrossRef] [Scilit]
- Yang, G.; Li, Y.; He, L.; Fu, H.; Wang, B. Continuous and precise recognition of N2H4 and Cu2+ has been achieved using chalcone derivatives as a D-A-D΄-type fluorescent chemical sensor. Microchem. J. 2024, 198, 110044. [Google Scholar] [CrossRef] [Scilit]
- Liu, C.; Shi, R.; Du, L.; Wang, W.; Yan, J.; Sun, Y. A long-lived ruthenium(II) complex-based time-gated luminescent probe for background-free detection of hydrazine hydrate. Chem. Commun. 2026, 62, 11674. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Oza, N.H.; Kasundra, D.; Deshmukh, A.G.; Borane, N.; Boddula, R.; Patel, P.N. Benzothiophene based semi-bis-chalcone as a photo-luminescent chemosensor with real-time hydrazine sensing and DFT studies. Environ. Sci. Adv. 2025, 4, 235–244. [Google Scholar] [CrossRef] [Scilit]
- Oza, N.H.; Chavda, V.B.; Patel, P.N. Semi-bis-enone photoluminophores enabling real-time fluorescence turn-off sensing of hydrazine: Synthetic, photophysical and XRD studies. J. Mol. Struct. 2026, 1366, 146093. [Google Scholar] [CrossRef] [Scilit]
- Oza, N.H.; Chavda, V.B.; Boddula, R.; Patel, P.N. A dual-mode semi-bis-enone fluorophore for hydrazine detection in real environmental samples: Design, mechanistic investigation and DFT insights. J. Photochem. Photobiol. A Chem. 2027, 482, 117555. [Google Scholar] [CrossRef] [Scilit]
- Kasundra, D.V.; Boddula, R.; Patel, P.N. Heterocyclic biphenyl-based fluorochrome sensor for rapid hydrazine detection: Design, synthesis, single crystal XRD, and DFT studies. Environ. Sci. Water Res. Technol. 2025, 11, 1629–1642. [Google Scholar] [CrossRef] [Scilit]
- Kasundra, D.V.; Boddula, R.; Giri, S.; Patel, P.N. Pyrene tagged dual absorption-emission sensor for selective hydrazine detection in environmental matrices: Design, mechanism and DFT insights. J. Mol. Struct. 2026, 1353, 144758. [Google Scholar] [CrossRef] [Scilit]
- Kasundra, D.V.; Patel, P.N. Pyrene aided dual mode fluorophore sensor for trace hydrazine detection in real environmental samples: Design, mechanism and DFT insights. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2026, 348, 127238. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xu, W.-Z.; Liu, W.-Y.; Zhou, T.-T.; Yang, Y.-T.; Li, W. A novel fluorescein-based “turn-on” probe for the detection of hydrazine and its application in living cells. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2018, 193, 324–329. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Amer, S.; Miles, U.; Firer, M.; Grynszpan, F. Turn-on Coumarin Precursor: From Hydrazine Sensor to Covalent Inhibition and Fluorescence Detection of Rabbit Muscle Aldolase. Molecules 2024, 29, 2175. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhou, H.; Huang, J.; Su, J.; Su, X.; Chen, Q.; Li, R.; Zheng, Y.; Chen, R.; Huo, L. Design and synthesis of novel angular 4,5-pyranocoumarin fluorescent probes for detecting hydrazine and their applications. RSC Adv. 2025, 15, 36525–36533. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Erdemir, S.; Oguz, M.; Malkondu, S. Real-time screening of hydrazine by a NIR fluorescent probe with low cytotoxicity in living cells and its multiple applications: Optimization using Box-Behnken Design. Sens. Actuators B Chem. 2022, 364, 131893. [Google Scholar] [CrossRef] [Scilit]
- Gong, Q.; Lai, Y.; Lin, W. A dual-color ESIPT-based probe for simultaneous detection of hydrogen sulfide and hydrazine. J. Mater. Chem. B 2024, 12, 5150–5156. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tian, Y.-M.; Liu, S.-S.; Wu, W.-N.; Zhao, X.-L.; Wang, Y.; Fan, Y.-C.; Xu, Z.-H.; James, T.D. A mitochondria-targeting fluorescent probe for the dual-emission fluorescence-enhanced detection of hydrogen sulfide and turn-on detection of hydrazine. Sens. Actuators B Chem. 2024, 409, 135496. [Google Scholar] [CrossRef] [Scilit]
- Oguz, M.; Aydin, D.; Malkondu, S.; Erdemir, S. A dual-channel smart fluorescent probe for rapid on-site detection of thiophenol and hydrazine in biological, environmental, and food samples. Food Chem. 2026, 508, 148540. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Erdemir, S.; Malkondu, S. Environmentally relevant dual-sensing of mercury (II) and hydrazine via reaction-induced fluorescence switching for real-sample and on-site monitoring. J. Hazard. Mater. 2026, 502, 141067. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Liu, P.; Wu, W.-N.; Wang, Y.; Fan, Y.-C.; Xu, Z.-H. A dual-ratiometric mitochondria-targeted fluorescent probe to detect hydrazine in soil samples and biological imaging. J. Hazard. Mater. 2022, 440, 129713. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Liu, L.; Xing, M.; Han, Y.; Zhang, X.; Li, P.; Cao, D.; Zhao, S.; Ma, L.; Liu, Z. Sensing for hydrazine of a pyrene chalcone derivative with acryloyl terminal group. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2022, 264, 120272. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jiang, Y.; Chen, Y.; Yang, Q.; Zhu, S.; Shen, J. Bifunctional fluorescent probe for detecting and imaging hydrazine hydrate both in vitro and in vivo. J. Mol. Struct. 2022, 1256, 132509. [Google Scholar] [CrossRef] [Scilit]
- Xie, F.; Zhang, Y.; Wang, L.; Ran, X.; Cao, D. Design, synthesis of novel unsymmetrical and NIR-emissive BF2 complexes and application in hydrazine detection. Dye. Pigment. 2025, 243, 113042. [Google Scholar] [CrossRef] [Scilit]
- Rajalakshmi, K.; Muthusamy, S.; Lee, H.-J.; Kannan, P.; Zhu, D.; Song, J.-W.; Nam, Y.-S.; Heo, D.N.; Kwon, I.K.; Luo, Z.; et al. Dual-channel fluorescent probe for discriminative detection of H2S and N2H4: Exploring sensing mechanism and real-time applications. J. Hazard. Mater. 2024, 465, 133036. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, D.; Liu, S.; Yang, X.; Jiang, B.; Ma, K.; Yang, J.; Yuan, X.; Yi, T. An Aggregation-Induced Emissive Platinum(II) Metallacycle as the Energy Donor of Rhodols for Ratiometric Detection of Hydrazine. ACS Appl. Mater. Interfaces 2024, 16, 55996−56005. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Meng, Z.; Li, X.; Ye, Q.; Zhang, S.; Xu, X.; Yang, Y.; Wang, Z.; Wang, S. A cellulose based fluorescent microsphere for sensitive detection and efficient removal of hydrazine and its versatile applications in environmental samples and live plants. J. Hazard. Mater. 2025, 492, 138253. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xu, Y.; Zhu, Z.; Tang, W.; Deng, H.; Zhang, J.; Yu, Y.; Shi, G.; Sun, K.; Gao, J. The dual colorimetric discrimination of dicyanovinyl−substituted poly (diacetylene) vesicle towards both dichloromethane and hydrazine with high selectivity. Dye. Pigment. 2025, 235, 112565. [Google Scholar] [CrossRef] [Scilit]
- Xu, Y.; Wang, J.; Tang, H.; Xu, J.; Wang, E.; Wang, F.; Ren, J. A near-infrared self-assembled micellar nanoprobe for highly selective detection of hydrazine. Tetrahedron Lett. 2023, 115, 154308. [Google Scholar] [CrossRef] [Scilit]
- Yang, M.; Mou, F.; Xiong, K.; Li, L.; Zhang, S.; Wang, F.; Gao, T.; Zhao, Z.; Guan, J. Tumbleweed-like aggregation-induced-emission microrobots: Swarming for ultra-tracing of hydrazine. Sens. Actuators B Chem. 2024, 412, 135794. [Google Scholar] [CrossRef] [Scilit]
- Cheng, J.; Luo, Y.; Hao, Y.; Han, H.; Hu, X.; Yang, Y.; Long, X.; He, J.; Zhang, P.; Zeng, R.; et al. A responsive organic probe based photoelectrochemical sensor for hydrazine detection. Spectrochim. Acta Part A-Mol. Biomol. Spectrosc. 2024, 305, 123463. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.












































