Abstract
V(V) removal using Lewatit S5428 and Lewatit S5528 was studied in batch and column experiments. V(V) adsorption was optimized by varying the adsorbent mass (0.01–0.1 g), pH (2–10), initial concentration (5–1000 mg/L), contact time (1–1440 min), and temperature (298–333 K). The adsorbents were characterized using SEM-EDS, ATR-FTIR, and XPS. Adsorption depended on all analyzed parameters, with Lewatit S5528 showing higher V(V) adsorption capacity. The maximum experimental adsorption capacities for V(V) ions were 181.2 mg/g for Lewatit S5428 and 226.3 mg/g for Lewatit S5528, respectively. Equilibrium data followed the Freundlich model, while kinetic data fitted the pseudo-second-order model best. Both intraparticle and film diffusion influenced adsorption kinetics. The equilibrium time was approximately 30–240 min for Lewatit S5428 and 15–60 min for Lewatit S5528, depending on the initial V(V) ion concentration (50–200 mg/L). The thermodynamic parameters indicated that the V(V) adsorption is spontaneous and exothermic. The loaded resins were efficiently regenerated with 1 mol/L NaOH solutions, and the main vanadium adsorption mechanism is ion exchange. The column experiments showed that Lewatit S5528 has a higher adsorption capacity than Lewatit S5428. A maximum overall V(V) removal efficiency of 98.22% was obtained for a 100-fold diluted real leachate (S1*) (C0 = 47.74 mg/L).